Item Part # Description Wiring Item #
FAN ASSEMBLIES, AND THERMOSTATS
A. 12W Standard Energy Efficient Fan Assembly (1)0477655 Fan Motor, Evaporator0461805 Fan Blade
CONTROL PANEL
B. lH59052001 Safe-NET® III Display (2)C. EP.4483429 Safe-NET® III Control (3)D. 0520584 Safe-NET® III Discharge Sensor (4)E. 0520585 Safe-NET® III Defrost Sensor (5)
1H16704003 Safe-NET® III Display Harness
REFRIGERATION
F. 0516897 Condensate Pump (6)G. 0519269 Condensate Pan & Heater (7)
(Evapoway)H. 0460992 TEV 2 Door Models
0460993 TEV 3-4-5 Door Models
Item Part # Description Wiring Item #
LED FIXTURES AND POWER SUPPLY
I. 0499399 Power Supply (8)
J. Door Lamp, LED BU.4440877 4100K Center (9)BU.4440878 4100K End (10)
K Facade Lamp, LED (11)BU.4441411 2900K 29.5 In. Length BU.4441412 2900K 30.5 In. Length
L. BU.4441414 Dry Goods Lamp, LED 3500K (12)
KLU9600 Dry Goods Shelf, Lighted, Pearwood
NOTE: For LED lighting parts contact your Hussmann servicerepresentative at 1-800-922-1919. Please have your model andserial number available. Descriptions including size and colorare at WWW.HUSSMANN.COM/SERVICEANDPARTS.
We reserve the right to changeor revise specifications andproduct design in connectionwith any feature of our products. Such changes do not entitle the buyer to corresponding changes,improvements, additions orreplacements for equipmentpreviously sold or shipped.
OPTIONS SHOWN:
• Lighted Facades
• Dry Goods Storage
• Bump Out Partitions
P/N_0520884_D©2012 HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A.U.S. & CANADA 1-800-922-1919 • MEXICO 1-800-890-2900 • WWW.HUSSMANN.COM
Refer to INNOVATOR REACH-IN GLASS DOOR
INSTALLATION AND SERVICE manual, P/N 0425683, for Innovator and Innovator II door and framereplacement parts.
® Freedom Line RMNwith INNOVATOR Doors
or INNOVATOR III Doors
Technical Data Sheet
P/N 0520884_DNSF® Certified
December 2012
NOTE: Revision D revises electrical and MOPD, page 6. Other changes marked by bar, underline or circle.
Warning: Terminal block
NOT for case-to-case
wire connection!
Freedom Linemerchandisersare top mountrefrigeration
ready
Freedom Line RMN with Innovator Doors Technical Data Sheet
2 of 13 U.S. & Canada 1-800-922-1919 • Mexico 1-800-890-2900
Reach-In2, 3, 4 & 5 Door
EngineeringPlan Views
PHYSICAL DATAMerchandiser Drip Pipe (in.) 1 1/4Merchandiser Liquid Line (in.) 3/8Merchandiser Suction Line (in.) 7/8
Freedom LineRLN - RMN Plan View
05-2011
Base narrow footprint 5-door merchandiser is shown above, without Bump Out, Dry Goods, Partitions or Ends.
Illustrated below is a 4-door merchandiser with Dry Goods cabinets and Bump Out end partitions.
Refer to chart on Page 3 for detailed dimensional information on options.
Dimensions shown as inches and (mm).
Dimensions shown as inches and (mm).
3 of 13P/N 0520884_D HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A. • WWW.HUSSMANN.COM
Freedom Line RMNWith Innovator Doors or Innovator III Doors
Medium Temperature
Plan View Dimensions for Freedom Line Options
Abbreviations: DG = Dry Goods section BO = Bump Out
2 Dr 3 Dr 4 Dr 5 Dr
General
(A) Merchandiser Length 62 (1575) 92 1/2 (2350) 122 7/8 (3121) 153 3/8 (3896)
(A) Merchandiser Length BO includes 2 bump-out ends 66 (1676) 96 1/2 (2451) 126 7/8 (3222) 157 3/8 (3997)
(A) Merchandiser Length DG includes 4 ends and dry goods cabinets 92 1/2 (2350) 123 (3124) 153 3/8 (3896) NA
Maximum O/S dimension of merchandiser back to front *** 39 3/4 (1010) 39 3/4 (1010) 39 3/4 (1010) 39 3/4 (1010)
Maximum O/S dimension of merchandiser back to front BO *** 51 3/4 (1314) 51 3/4 (1314) 51 3/4 (1314) 51 3/4 (1314)
*** Includes bumper. Add 26 1/2 in. (673 mm) for door swing.
Interior width of dry goods cabinet 10 3/4 (273) 10 3/4 (273) 10 3/4 (273) NA
Interior depth of dry goods cabinet 12 7/8 (327) 12 7/8 (327) 12 7/8 (327) NA
Back of merchandiser to rear of splashguard 35 7/8 (911) 35 7/8 (911) 35 7/8 (911) 35 7/8 (911)
Back of merchandiser to rear of splashguard BO 47 7/8 (1216) 47 7/8 (1216) 47 7/8 (1216) 47 7/8 (1216)
Width of Skid rail 3 3/4 (95) 3 3/4 (95) 3 3/4 (95) 3 3/4 (95)
Width of Bottom Front Support 6 (152) 6 (152) 6 (152) 6 (152)
Stub-up area between front support and splashguard 3 1/8 (79) 3 1/8 (79) 3 1/8 (79) 3 1/8 (79)
Electrical Service
(B) RH end of merchandiser to the center of nearest electrical service area 4 (102) 4 (102) 4 (102) 4 (102)
(B) RH end of merchandiser to the center of nearest electrical service area BO 6 (152) 6 (152) 6 (152) 6 (152)
(B) RH end of merchandiser to the center of nearest electrical service area DG 19 1/4 (489) 19 1/4 (489) 19 1/4 (489) NA
Back O/S of merchandiser with bump-out to center of electrical service area 49 5/8 (1260) 49 5/8 (1260) 49 5/8 (1260) 49 5/8 (1260)
* NOTE: Electrical Field Wiring Connection Point is at top.
Waste Outlet
(C) Right end of merchandiser to center of waste outlet 23 7/8 (606) 54 1/4 (1378) 46 1/4 (1175) 76 5/8 (1946)
(C) Right end of merchandiser to center of waste outlet BO 25 7/8 (657) 56 1/4 (1429) 48 1/4 (1226) 78 5/8 (1997)
(C) Right end of merchandiser to center of waste outlet DG 39 (991) 69 1/2 (1765) 61 1/2 (1562) NA
Back O/S of merchandiser with bump-out to center of waste outlet 42 5/8 (1083) 42 5/8 (1083) 42 5/8 (1083) 42 5/8 (1083)
Water Seal
Edge of water seal to center of waste outlet 13 (330) 13 (330) 13 (330) 13 (330)
Schedule 40 PVC drip pipe 1 1/4 (32) 1 1/4 (32) 1 1/4 (32) 1 1/4 (32)
** NOTE: Field installed water seal outlets, tees, and connectors are shipped with merchandiser.
Refrigeration Interface
(D) RH end of merchandiser to center of refrigeration interface 5 3/8 (136) 5 3/8 (136) 5 3/8 (136) 5 3/8 (136)
(D) RH end of merchandiser to center of refrigeration interface BO 7 3/8 (187) 7 3/8 (187) 7 3/8 (187) 7 3/8 (187)
(D) RH end of merchandiser to center of refrigeration interface DG 20 5/8 (524) 20 5/8 (524) 20 5/8 (524) NA
Back O/S of merchandiser with bump-out to center of refrigeration interface 44 (1118) 44 (1118) 44 (1118) 44 (1118)
* NOTE: Refrigeration Interface point is at top.
Outside bottom front supports from end of merchandiser 7 (178) 7 (178) 7 (178) 7 (178)
Outside bottom front supports from end of merchandiser BO 9 (229) 9 (229) 9 (229) 9 (229)
Outside bottom front supports from end of merchandiser DG 26 1/2 (673) 26 3/4 (679) RH 24 (610) 24 (610)
37 1/2 (952) LH
Center bottom front support from Centerline 24 (610) 24 (610) 24 (610) 24 (610)
Center bottom front support from Centerline BO 24 (610) 24 (610) 24 (610) 24 (610)
Center bottom front support from Centerline DG 6 3/4 (171) LH 8 3/4 (222) RH 24 (610) NA
Distance between Center and Outside supports will vary
(E) Depth when disassembled for door entry 35 1/2 (902) 35 1/2 (902) 35 1/2 (902) 35 1/2 (902)
Freedom Line RMN with Innovator Doors Technical Data Sheet
4 of 13 U.S. & Canada 1-800-922-1919 • Mexico 1-800-890-2900
Facade Cross Section
Partition and End ProfilesDry Goods Cross-Section
Freedom Line RMNWith Innovator Doors or Innovator III Doors
Medium Temperature
REFRIGERATION DATA
Note: This data is based on store temperatureand humidity levels that do not exceed NSFguidelines.
MEDIUM TEMP
Discharge Air °F 32
DEFROST DATAFrequency (hr) 24Defrost Water (lb/Dr/day) 0.36(± 15% based on case configuration and productloading.)
OFFTIME 60 minutes
CONVENTIONAL CONTROLSCut In Cut Out
HPC (psig) 320 395
LPC (psig) 15 5
Working charge with recommendedCondensing Unit installed:
2Dr 2.3 lb 37 oz 1.0 kg3Dr 3.2 lb 51 oz 1.5 kg4Dr 3.7 lb 59 oz 1.7 kg5Dr 6.8 lb 109 oz 3.1 kg
Recommended Hussmann Condensing Unit:
Capacity Model2Dr 1000 Btu/hr TCMA3Dr 1500 Btu/hr TCMB4Dr 2000 Btu/hr TCMC5Dr 2500 Btu/hr TCMD
based on 27ºF (–2.8ºC) Evaporator temperature for low temperature applications.
Dimensions shown as inches and (mm).
Freedom Line Narrow Footprint Reach-inTop-Mount-Refrigeration Ready2, 3, 4 and 5 Door Models
5 of 13P/N 0520884_D HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A. • WWW.HUSSMANN.COM
NSF CertificationThis merchandiser model is manufactured to meet NSF/ANSI(National Sanitation Foundation) Standard #7 requirementsfor construction, materials & cleanability.
Freedom LineRLN - RMN
Hussmann refrigerated merchandisers configured for sale for use in the United States
meet or surpass the requirements of the DOE 2012 energy efficiency standards.
Freedom Line RMNWith Innovator Doors or Innovator III Doors
Medium Temperature
Note: Facade is field-installed.Electrical connection box,external supports, door handle and front racewaymay be removed to facilitate passage through door way.
Provide adequate clearance for air circulation at rear to reduce condensation.
Electrical Data
2Dr 3Dr 4Dr 5Dr
Number of Fans—12W 2 3 4 5
Amperes Watts
Merchandiser 2Dr 3Dr 4Dr 5Dr 2Dr 3Dr 4Dr 5Dr
120V Circuit
(Fans, anti-sweat heaters, drain pan heater, condensate pan heater, condensate pump, and standard Ecoshine 2 LED's)
With Innovator Doors (standard) 8.0 8.8 9.6 10.5 813 877 939 1003
Maximum Overcurrent
Protection Device (MOPD) 20 20 20 20
Refer to condensing unit data sheet for additional condensing unit electrical requirements.†
Standard Vertical LED Lighting 4100K 2Dr 3Dr 4Dr 5Dr 2Dr 3Dr 4Dr 5Dr
Hussmann EcoShine II ™ [22 W] (120V) Included above)
Optional LED Lighting (24VDC)
Facade Lamps 0.79 1.17 1.54 1.92 19 28 37 46
Dry Goods Lamps (both sides, 10 per side) 1.50 1.50 1.50 NA* 36 36 36 NA*
* Dry Goods sections are not available on 5-Door models.
† Notes:
1. Electrical input for the RMN Freedom cases require two electrical connections at the top of the case: one 120V connection for
the RMN and one 208/230V or 120Vconnection for the condensing unit.
2. The condensing unit amps must be used to calculate the total electrical load. Refer to the condensing unit data sheet.
3. Without heated condensate pan and pump, subtract 2.4 Amps
Freedom Line RMN with Innovator Doors Technical Data Sheet
6 of 13 U.S. & Canada 1-800-922-1919 • Mexico 1-800-890-2900
Freedom Line RMNWith Innovator Doors or Innovator III Doors
Medium Temperature
Hussmann recommends against frame heater cyclingwith Innovator doors or Innovator III doors to preventdoor seals from freezing to the frames and tearing.
7 of 13P/N 0520884_D HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A. • WWW.HUSSMANN.COM
Product Data
Recommended Usable Cube 1 (Cu Ft/Dr) 22.80 ft3 /Dr (0.65 m3 /Dr)AHRI Total Display Area 2 (Sq Ft/Dr) 13.31 ft2 /Dr (1.24 m2 /Dr)Shelf Area 3 (Sq Ft/Dr) 28.50 ft2 /Dr (2.65 m2 /Dr)
1 AHRI Refrigerated Volume less shelving and other unusable space: Refrigerated Volume/Unit of Length, ft3/ft [m3/m]2 Computed using AHRI 1200 standard methodology: Total Display Area, ft2 [m2]/Unit of Length, ft [m]3 Shelf surface area is composed of bottom deck plus standard shelf complement, as shown in the Hussmann
Product Reference Guide. The standard shelf complement for this model is (5) rows of 22-inch shelves.
Product Data (Dry Goods Area Only)
TOTAL Gross Usable Cube (Volume for 2 DG per merchandiser) 10.33 ft3 / (0.29 m3 )
ESTIMATED SHIPPING WEIGHT 4
2 Dr 3 Dr 4 Dr 5 Dr Solid End (each)
Standard Freedom Line Merchandiser (18-Inch Facade, no Arch)
lb (kg) 1005 (456) 1262 (572) 1688 (766) 2070 (939) 74 (34)
Freedom Line Merchandiser with Two (2) Bump Out Partitions (18-Inch Facade, no Arch)
lb (kg) 1185 (538) 1442 (654) 1868 (847) 2250 (1021) N/A
Freedom Line Merchandiser with Two (2) Dry Goods Sections, Four (4) Partitions (18-Inch Facade, no Arch)
lb (kg) 1481 (672) 1738 (788) 2164 (982) NA N/A
Freedom Line Merchandiser with
Two (2) Bump Out Partitions, Two (2) Dry Goods Sections, Two (2) Partitions (18-Inch Facade, no Arch)
lb (kg) 1522 (690) 1779 (807) 2205 (1000) NA N/A
4 Actual weights will vary according to optional kits included.
Freedom Line RMNWith Innovator Doors or Innovator III Doors
Medium Temperature
Freedom Line RMN with Innovator Doors Technical Data Sheet
8 of 13 U.S. & Canada 1-800-922-1919 • Mexico 1-800-890-2900
9 of 13P/N 0520884_D HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A. • WWW.HUSSMANN.COM
Safe-NET™ Wiring Diagram — Medium Temperature Reach-in with 2 or 3 Doors
Freedom Line RMNWith Innovator Doors or Innovator III Doors
Medium Temperature
Freedom Line RMN with Innovator Doors Technical Data Sheet
10 of 13 U.S. & Canada 1-800-922-1919 • Mexico 1-800-890-2900
0520531 ASafe-NET™ Wiring Diagram — Medium Temperature Reach-in with 4 or 5 Doors
Freedom Line RMNWith Innovator Doors or Innovator III Doors
Medium Temperature
11 of 13P/N 0520884_D HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A. • WWW.HUSSMANN.COM
Optional Lighting
LED Fixtures
Hussmann
EcoShine™
Freedom Line RMNWith Innovator Doors or Innovator III Doors
Medium Temperature
Freedom Line RMN with Innovator Doors Technical Data Sheet
12 of 13 U.S. & Canada 1-800-922-1919 • Mexico 1-800-890-2900
Optional Lighting Circuits
Freedom Line RMNWith Innovator Doors or Innovator III Doors
Medium Temperature
13 of 13P/N 0520884_D HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A. • WWW.HUSSMANN.COM
Optional Lighting Circuits
Freedom Line RMNWith Innovator Doors or Innovator III Doors
Medium Temperature