+
++
+
+
+
+
+
+
+
+
+
++
+
+
+
+
++
+
+
+
+
+
+
+
+
+
++ +
+
+
+
+
+
GROUP PROFILE
Okaya is a flagship company of Okaya Power Group , a multi - billion INR conglomerate and a symbol of trust for over 38 years.
Established in 1980, Okaya Power Group has a dominating presence in tubular inverter batteries, SMF / VRLA, automotive, solar batteries, e-rickshaw batteries, healthcare products (RO Water Purifiers), software development and real estate. Latest addition in the bouquet is Lithium battery , Electric Vehicle Chargers and Charging Stations.
Year 2002 saw emergence of Okaya as India’s Leading battery manufacturing company. With a widespread product range and applications it has become a symbol of trust.
Supported with one of the largest channel network and service set-up all across the country has 9 state of art manufacturing units, 2 central warehouses, 31 regional warehouses and branch offices spread across 29 states.
Time and tide has helped Okaya achieved global presence and a respectable position in domestic market. It imbibes integrity, innovation, trust and customer relationship as core values.
Now ventured into Lithium Battery and EV Charger segment to re-create history of leadership once again and place itself in a numero uno position.
OKAYA GROUP COMPANIES
TM
INFRASTRUCTURES
omposite Charging stations are especially designed to provide public transport vehicles and fleets Cwith fast one stop charging service.
The charging stations are equipped with big charger base, logistics, intelligent controls, back-end support and operations management, surveillance systems to cater a most efficient and safe one stop charging solution for growing public transport system and fleet support.
The charging station is consist of split or integrated charging system (charger) high / low voltage power distribution, large shades and bay layout, communication system, operations monitoring and management system.
CHARGING STATION SOLUTION FOR TRANSPORT & FLEET
01
SALIENT FEATURES
Long-range EVs charging spots
Bus Depot
Airport Terminal
Fleet Services
Highway Side Charging Station
DESCRIPTIONS
Charger Models§ 360 kW split charging pile with 6 Charging guns.§ 600 kW split charging pile with 10 charging guns.§ 1200 kW split charging pile with 20 charging guns.
Power DistributionPackaged Substation, Cables, HV and LV distribution cabinet.
Shade ShapeSolar powered canopy (PV Canopy) and Steel structure canopy.
Communication systemsCombing the charging station access solution, the charging station network connecting the outer network and the inner network uses optical fiber network, cable network connected to the operations management systems of the charging pile via optical router or wireless router.
Video Monitoring SystemsPTZ cameras, Communication networks.
Operations managements systemOperation, Management and monitoring of charging pile, sharing of big data and IOT.
Fire fighting systemsThe space between charging station and buildings should comply with the fire safety requirements, entrance and exit design should comply with the evacuation requirements of charging station and buildings should be equipped with fire extinguishers and fire alarm systems.
02
CompositeCharging Solution
MobileApp
Monitoringsystem platform
Chargingmonitoring
Meteringand billing
Videomonitoring
Cloud serversGPRS Ethernet
Ethernet
Industrialswitches
AC380V
Packaged substationGrid
LV distribution
These Charger able to charge all Electric Vehicles of IEC 60309 (Bharat Ac001), IEC 62196 - 2 (Type 2 AC), CCS - 2, CHAdeMO & GB/T charging standards compliance in AC Charger 230V or 415V and in DC Charger output voltage up to 750/1000 V.
After user identification by simply choosing the charging standard compatible to your vehicle and coupling the charger’s output plug to the EV, you will have a fast secured and proven charging process. The battery charging status is displayed and the charging cycle finishes by itself or can be terminated by an user command.
Different output options are available, like the basic single output, dual output or even triple outputs, in a single cabinet or bundled with a wired charging interface kiosk.
03
STAND ALONE CHARGER
Charge your Wheelze
With Okaya eScooter, eRickshaw, eCar, eBus & eTruck Charging Infrastructure
FEATURES
APPLICATIONS
EV Infrastructure and operators
EV fleet (private and public)
EV dealers and service providers
Restaurants
Shopping Centers
Chargingcloud
platform
Scan codecharging
Ip54 Adapt tomultiplevehicles
User-FriendlyWarranty
*
5YEARS
AvailableDC Outputs
KW
KW
KW
KW
15 20
50 100
RemoteUpdate
AvailableAC Outputs
KW
KW
KW
KW
3.3 7.4
11 22
Private / Public Parking
Super Market and Shopping Centers
Car-Share, Taxi and Rent a car fleets
Service, Commercial and Distribution fleets
Long-range EVs charging spots
Bus Depot
Airport Terminal
Fleet Services
Highway Side Charging Station
04
TECHNICAL SPECIFICATIONS
Subject to change without prior notice
GB/T Chargers
15 kW 20 kW 50/60 kW
Input Voltage (Vac)
Input Frequency
THD
Power Factor
Wires
Output Voltage - DC (Vdc) 40 - 100 vdc 40 - 100 vdc200 - 750/1000
vdc
Standard/Connector
Number of Connector/Gun 1 2 1
Efficiency
Protection and Safety Saftey Parameters
Display Screen
Languages- Supported
Push Button
Charging Option
Visual Indication
User Authentication
Payment
Between EV Charger and EV
Between EV and Central Server
Protection
Cooling
Charging Cable Length
Operating Temperature
Storage Temperature
Humidity (Non-Condensing)
Altitude
380 - 480 V
50 Hz
≤ 5% of Nominal Voltage
≥ 0.99 (Full load)
3 - Phase, 5 - Wire AC ( L1, L2, L3, N and PE)
Emergency Stop (Mushroom Red)
English
7" TFT LCD Touch Screen
Over Voltage, Under Voltage, Surge Voltage, Short Circuit,
Over Temperature and Leakage Current
≥ 94 %
- 20° C to 55 ° C
5 Meter
Forced Air Collong
GB/T 20234.3
OCPP v 1.6 or above - 10/100 Base-T Ethernet (Standard) /
Optical GSM Modem (2G/3G/4G) or Wireless
CAN based Communication as per AIS 138-2
RDIF Card Wallet or App Wallet/Service
RFID /QR / AppBased OTP
Presence of Input Supply, Errors Indicator, State of Charge
Grid Responsive metering
Capacity
Input Parameters
IP 54
Communication
Mechinical
Power Output
User Interference and
Control functions
upto 2000 mtr
5% to 95%
- 20° C to 60 ° C
TECHNICAL SPECIFICATIONS CCS-2 & CHAdeMO Chargers
Subject to change without prior notice
05
50/60 kW 50/60 kW
Input Voltage (Vac)
Input Frequency
THD
Power Factor
Wires
Output Voltage - DC (Vdc)
Standard / Connector CCS-2 CHAdeMO
Number of Connector / Gun 1 1
Charging Standard CCS-2 CHAdeMO
Efficiency
Protection and Safety
Saftey Parameters
Display Screen
Languages- Supported
Push Button
Charging Option
Visual Indication
User Authentication
Payment
Between EV Charger and EV PLC Communication CAN Communication
Between EV and Central Server
Protection
Cooling
Charging Cable Length
Operating Temperature
Storage Temperature
Humidity (Non-Condensing)
Altitude
RDIF Card Wallet or App Wallet / Service
5% to 95%
upto 2000 mtr
OCPP v 1.6 or above - 10/100 Base-T Ethernet (Standard) / Optical GSM Modem (2G / 3G / 4G) or Wireless
IP 54
Forced Air Collong
5 Meter
- 20° C to 55 ° C
- 20° C to 60 ° C
Mechinical
Power Output
User Interference and
Control functions
380 - 480 V
50 Hz
� 5% of Nominal Voltage
� 0.99 (Full load)
3 - Phase, 5 - Wire AC ( L1, L2, L3, N and PE)
150 - 550 vdc/200 - 750 vdc / 200 - 1000 vdc
English
Capacity
Input Parameters
� 94 %
Over Voltage, Under Voltage, Surge Voltage, Short Circuit, Over Temperature and Leakage Current
7" TFT LCD Touch Screen
Communication
Emergency Stop (Mushroom Red)
Grid Responsive metering.
Presence of Input Supply, Errors Indicator, State of Charge
RFID / QR / AppBased OTP
3 in 1 ChargerTECHNICAL SPECIFICATIONS
Subject to change without prior notice
06
50 kW +43 kW 120 kW +43 kW
Input Voltage (Vac)
Input Frequency
THD
Power Factor
Wires
DC Output 1 CCS -2, (50 kW/60 kW) CCS -2, 60 kW
DC Output 2 CHAdeMO, (50 kW/60 kW) CHAdeMO, 60 kW
AC Output 3
Output Voltage - DC (Vdc)
Standard / Connector
Number of Connector / Gun
Charging Standard
Efficiency
Protection and Safety
Saftey Parameters
Display Screen
Languages - Supported
Push Button
Charging Option
Visual Indication
User Authentication
Payment
Between EV Charger and EV
Between EV and Central Server
Protection
Cooling
Charging Cable Length
Operating Temperature
Storage Temperature
Humidity (Non-Condensing)
Altitude
- 20° C to 55 ° C
- 20° C to 60 ° C
5% to 95%
upto 2000 mtr
RDIF Card Wallet or App Wallet/Service
CAN(CHAdeMO), PLC (CCS-2) and Type-2 AC as per IEC 61851-1
OCPP v 1.6 or above - 10/100 Base-T Ethernet (Standard) / Optical GSM Modem (2G/3G/4G) or Wireless
IP 54
Forced Air Collong
5 Meter
English
� 94 %
Emergency Stop (Mushroom Red)
Grid Responsive metering
Presence of Input Supply, Errors Indicator, State of Charge
RFID / QR /AppBased OTP
150 - 550 vdc / 200-750 vdc/ 200 - 1000 vdc
CCS - 2, IEC 62196 Type-2 and CHAdeMO
3
PLC(CCS Combo 2)and AC Type-2 as per IEC 61851-1 and CHAdeMO
Over Voltage, Under Voltage, Surge Voltage, Short Circuit, Over Temperature and Leakage Current
7" TFT LCD Touch Screen
380 - 480 V
50 Hz
� 5% of Nominal Voltage
� 0.99 (Full load)
3 - Phase, 5 - Wire AC (L1, L2, L3, N and PE)
Type 2, AC 3 Phase, upto 43 kW Max
Communication
Mechinical
Power Output
User Interference and Control
functions
Capacity
Input Parameters
TECHNICAL SPECIFICATIONS Bharat AC 001 & Type - 2 Charger
Subject to change without prior notice
07
7.4 kW 22 kW 10 kW 3.3 kW
Input Voltage(AC) 230 VAC, 50Hz380-480 Vac, 50
Hz380-480 Vac, 50
Hz230 VAC, 50Hz
Wires 3 Wire, L, N, PE5 Wire, L1, L2, L3,
N, PE5 Wire, L1, L2, L3,
N, PE3 Wire, L, N, PE
Number of Outputs 1 Nos. 1 Nos. 3 Nos. 1 Nos.
Output Connector IEC 60309 IEC 60309
Output 1 Rating230 VAC, max.
32 Amp415 VAC, max. 32
AmpEach Outlet 230
VAC, max.16 Amp 230 VAC,
max.16 Amp
Ambient Temperature
Storage Temperature
Altitude
Humidity
Display
Language
Push Button
User Authentication
Visual Indication
Protection Protection
Charger & Vehicle
Charger & CMS
Ingress Protection
IP Rating
TYPE-2 As per IEC 61851-1
Charger Type
System Capacity
Input Power
Output Power
Environment
User Interface & Control
Using LED
Mechanical
Emergency Stop
Over Voltage, Under Voltage, Over Current, Short Circuit, Surge Protection, Over Temperature, Ground Fault, Residual Current
RFID / QR / APP BASED OTP
As per BEVC-AC0001 Specification
Protocol: OCPP 1.6 or above, Interface : Ethernet, 2G/3G/4G, Wi-Fi (Optional)
Indoor & Outdoor
IK 10 / IP 54
Communication
AC Charger
-20°C to 55°C
-20°C to 60°C
<2000 Mtr.
5% TO 95%, non condensing
English
IEC 62196 Type-2
4.3"/ 7" TFT LCD with Touch
08
Cloud platform
APP
SCAN
CHARGER
PLATFORMMANAGEMENT
BHIM PAYMENT
WEB
Intelligent charging platform consists of operating management system, application website, Android App Charging equipment. The platform provides users with the services of charging quick search, advanced reservation, map direction, status enquiry, wallet services & account management. This platform not provide only support but also provide various special offers for end user.
CLOUD PLATFORM SERVICES
E-RICKSHAW LITHIUM BATTERY CHARGERS
Intelligent Battery Charger
09
Subject to change without prior notice
TECHNICAL SPECIFICATIONS OPG 4832 54.75V/30A
10
DescriptionThe purpose of the document is to specify the functional requirements of a 1642.5W
charge of Lifep04.
Specified Voltage: 220Vac
Adjustment Range: 200-240 Vac
Nominal Frequency: 50/60Hz
Variation Frequency: 47-63Hz
Max Input Current 10A max at any input voltage and rated, DC output rated load.
Surge Current50 A Max. Cold start at 230Vac input, with rated load and 25 deg. celcius is ambient
temp.
Charge Voltage Max. Charging Current Turn Lamp Current Max. Output Power
54.75V±1% 30A±2% 1.5A 1642.5W
Charging Voltage Max.Charge Voltage Line adjustment Load adjustment
54.75V 54.75V ±1% ±5%
Efficiency 91%Min.At 220Vac input and output Max. Load.
Short Circuit Protection The power supply will be auto recovered when short circuit faults remove.
Over current Protection The power supply will be auto recovered when over current faults remove.
Over Voltage Protection The power supply will not be auto recovered when faults remove.
Operating Temperature -20℃~-10 celcius
Storage Temperature -20℃ to 85℃, (With package)
Safety EN60950
PROTECTION Functions
SAFETY AND EMC REQUIREMENT
ENVIRONMENTAL REQUIREMET
INPUT CHARACTERISTICS
OUTPUT CHARACTERISTIC
Input Voltage
Input Frequency
Output Power
Load characteristics /Line
Adjustment
E-RICKSHAW LEAD ACID BATTERY CHARGERS
2WITH M FC TECHNOLOGY
11
Saves Electricity
Easy Service
More Battery Life
More Mileage Fast Charging
High frequency PWM circuit
Microcontroller based SMPS Battery charger
Multi-stage charging reduces over heating
Protection against reverse polarity
Over temperature shut down High grade magnetics for low standby losses
Protection against reverse polarity Compact, light weight, portable & shockproof
Protection against input surge & inrush current In-built over voltage protection
TECHNICAL SPECIFICATIONS
MODEL
170V-300VAC, 47-63Hz
OERBC-4812
7.0Amp max
12.0Amp + 0.5Amp
+ 2%
+ 2%
< 1%
Automotive
>90%
63V + 1V
Input Voltage
Input Current
Boost Charging Current
Line Regulation
Load Regulation
Ripple Voltage at Resistive Load
Boost to trickle change-over voltage
Boost / Trickle Change-over
Efficiency
170V-300VAC, 47-63Hz
OERBC-4815
8.0Amp max
15.0Amp + 0.5Amp
+ 2%
+ 2%
< 1%
Automotive
>90%
63V + 1V
Specifications are subject to change without notice.The company does not take liability for consequential damages.
FEATURES
12
OPG E-MOTORS PVT. LTD.