Over the past 45 years, Hawke has built a world-wide reputation in the Hazardous Area and Hostile Environment markets, with an innovative range of cable connection, termination and barrier products.
The underlying philosophy behind our Corporate Strategy has been a recognition of the fundamental principle that our products are concerned with safety, in an environment where failure can have catastrophic consequences to human life, the environment, expensive plant and valuable production - and in situations where the replacement of faulty components is often difficult.
This philosophy requires an enthusiastic participation in the development of new Safety Standards and Codes of Practice, and a product development programme which embraces these, together with advances in cable construction and materials. It requires that our products should be easy to select and install, because these activities are not only expensive but also affect the safety of the assembly. It requires that we provide informed technical advice, that our staff and customers are thoroughly trained, and that we have quality systems and a manufacturing plant which ensure Zero Defects. It means that we must transcend the mere requirements of having the "appropriate certification" and that we exceed the undemanding requirement that products be "fit for purpose" - whose purpose?
All the products we make (from Fire Barrier Transit systems to Fieldbus Power Supply systems) have a common underlying theme, which forms the basis of our Product Development Strategy :-
Product Development is an ongoing process, in which Hawke continues to invest heavily, and the cable glands described within are the culmination of a particularly concentrated effort over recent years.
The new rear sealing system not only meets the new ATEX Directive, but also uses a unique clamping system, giving higher retention forces than any other similar product on the market. It uses a new thermoset elastomer compound which provides superb resistance to high and low temperatures, to the ageing effects of Oxygen and Ozone, and Compression Set. It has the added benefit of being halogen-free, with low smoke and fume emission . . . . but, above all, it is safe. The system has the versatility to seal the entire range of cable sizes that can be accommodated by a particular entry size, without the need for special outer seals. This makes the cable gland easier and quicker to use, with less likelihood of an installer using the wrong seal. It also means easier product selection, and fewer items for our distributors to keep in stock, which should in turn mean improved stock availability. The cable acceptance range is marked on the rear nut, affording easier inspectability.
An example from our new range of cable glands illustrate these principles :-
As a company, we have all the obvious targets in terms of On-Time Delivery and Customer Service, Zero Defects, Investment in Manufacturing Facilities, and in the Training and Development of our People - and we perform to World-Class Standards,but . . . .
if there is one message we want to get across, it is our overriding concern for SAFETY.
Safety, Integrity and InspectabilityVersatility and ease of product selection
Ease and speed of useLowest lifetime cost solutions
Quality and Reliability
Introduction
1
Smarter productswww.ehawke.com
Cable Gland Selection Chart 4 - 6
ATEX Hazardous Area Cable Glands, (CENELEC, IEC) 7 - 20
Industrial General Purpose Cable Glands 21 - 27
North American Explosionproof and General Purpose Cable Glands 28 - 32
Cable Gland Accessories 33 - 37
Cable Gland Variations and Options 38
Hazardous Area Guidelines 39 - 66
Page No.
1.0 Potentially Explosive Atmospheres 39
2.0 Area Classification (Classification of Locations) 39
3.0 CENELEC and IEC Hazardous (Classified) Locations 39 - 43 3.1 Areas Classification 39 3.2 Classification Society 40 3.3 Design and Installation of Electrical Systems for Hazardous (Classified) Areas 40 3.4 Apparatus Selection According to Zones 41 3.5 Apparatus Selection According to the Ignition Temperature of the Gas or Vapour 41 3.6 Apparatus Selection According to Apparatus Grouping 42 3.7 Apparatus Construction Standards 42 3.8 Installation Standards and Codes 42 3.9 Inspection Standards and Codes 43
4.0 ATEX 94/9/EC Directive 43 - 444.1 ATEX 137 Directive 99/92/EC 44
5.0 Wiring Systems 45 - 48
5.1 CENELEC and IEC Wiring Methods 455.2 Wiring Methods for Type of Protection 'd' - Flameproof Enclosure 46 5.3 Wiring Methods for Type of Protection 'e' - Increased Safety 48
Contents
International2
Smarter productswww.ehawke.com
13.0 Abbreviations, Accronyms and Definitions 62 - 65
Page No.
7.0 CE Marking 49 7.1 EMC, Electromagnetic Compatibility Directive 49 7.2 Low Voltage Directive 49
8.0 Certification/Listing/Approvals 49
9.0 CENELEC and IEC Degree of Protection, IP Code 50 - 56 9.1 Deluge Ingress Protection 51
10.0 IECEx Scheme 51
11.0 North American Hazardous (Classified) Locations 51 11.1 Area Classification 51 11.2 Apparatus Selection According to Class 1 53 11.3 Apparatus Selection According to the Ignition Temperature of the Gas or Vapors 54 11.4 Apparatus Selection According to the Ignition Temperature of the Dust 54 11.5 Apparatus Selection According to Apparatus Grouping 54 11.6 Apparatus Construction Standards 55 11.7 Installation Standards and Codes 56
12.0 Wiring Systems 56 - 61 12.1 National Electrical Code (NEC) Wiring Methods 56 12.2 Cable Seals, Class 1, Division 1 57 12.3 Cable Seals, Class 1, Division 2 57 12.4 United States Coast Guard - Wiring Methods 57 12.5 American Petroleum Institute - Wiring Methods 58 12.6 National Electrical Code (NEC) Zone Equipment Marking 60 12.7 National Electrical Code (NEC) Division Equipment Marking 60 12.8 North American Ingress Protection 61
6.1 Additional ATEX Marking 486.2 Additional CE Marking 49
6.0 Apparatus Marking - CENELEC and IEC (Group II) 48 - 49
Contents
International3
Smarter productswww.ehawke.com
Cable Gland Selection Chart
International
ColourCoded
Catalogue Page No.
Cable GlandType
Pictorial View
Certification
CertificationOptions
IngressProtection
Sealing
Application/Cable Type
PSG 553/RAC
501/453/UNIV
501/453/RAC/L
501/453/RAC
IP66/67/68Deluge
IP66/67/68(Deluge option)
IP66/67/68(Deluge option)
IP66/67/68(Deluge option)
IP66/67/68Deluge
IP66/67/68Deluge
IP66/67/68Deluge
IP66/67/68Deluge
IP66/67/68Deluge
Indoor/outdoorArmoured/braided cable with
inner (optional) and outer sheath
Indoor/outdoorArmoured/braided cable with
inner lead sheath and outer sheath
Indoor/outdoorArmoured/braided cable with
inner lead sheath and outer sheath
Indoor/outdoorNon-armoured cable
Outer cable sheath seal
Two outer cable sheath seals
Inner and outer cable sheath seals
Inner lead sheath seal/electrical bond
and outer cable sheath seal
Inner (diaphragm) and outer
cable sheath seals
Inner (compound) and outer
cable sheath seals
Individual conductor seal
and outer cable sheath seal
Inner (compound) and outer
cable sheath seals
Inner (compound) seal, lead sheathelectrical bond
and outer cable sheath seal
Indoor/outdoorNon-armoured cable
Indoor/outdoorNon-armoured cable
Indoor/outdoorArmoured/braided cable with
inner and outer sheath
Indoor/outdoorArmoured/braided cable with
inner and outer sheath
Indoor/outdoorArmoured/braided cable with
inner (optional) and outer sheath
501/423
501/4217
8
9
10
11
12
13
14
15
16
ICG 653/UNIV
ICG 653/UNIV/L
ATEXEExd IIC/EExe II
Zone 1, 2, 21 & 22
ICG 623
II 2 GD
IEC
IEC
IEC
IEC
IEC
IEC
IEC
IEC
IEC
IEC
IP66/67/68Deluge
Indoor/outdoorNon-armoured cable,
conduit system
Outer cable sheath seal
501/414
ATEXEExd IIC/EExe II
Zone 1, 2, 21 & 22II 2 GD
ATEXEExd IIC/EExe II
Zone 1, 2, 21 & 22II 2 GD
ATEXEExd IIC/EExe II
Zone 1, 2, 21 & 22II 2 GD
ATEXEExd IIC/EExe II
Zone 1, 2, 21 & 22II 2 GD
ATEXEExd IIC/EExe II
Zone 1, 2, 21 & 22II 2 GD
ATEXEExd IIC/EExe II
Zone 1, 2, 21 & 22II 2 GD
ATEXEExd IIC/EExe II
Zone 1, 2, 21 & 22II 2 GD
ATEXEExd IIC/EExe II
Zone 1, 2, 21 & 22II 2 GD
ATEXEExd IIC/EExe II
Zone 1, 2, 21 & 22II 2 GD
4
To the best of our knowledge the information contained in this brochure, is accurate at the time of going to print and the company reserves the right to improve or modify any product illustrated without notification. The company is unable to accept liability for any inaccuracies, errors or omissions that may exist. It is the customer's responsibility to ensure that the product is suitable for their application.
All copyright reserved-Hawke Cable Glands Ltd 2001.This document and all copyright therein is the property of: Hawke International a trading name of Hawke Cable GlandsLtd (A member of the McKechnie Group of Companies).Copyright Condition: This document shall be used only for the purpose for which it is provided and no reproduction or publication of the document may be made and no article may be manufactured or assembled in accordance with information contained in the document without prior written consent of the owner.
Smarter productswww.ehawke.com
Cable Gland Selection Chart
ColourCoded
Catalogue Page No.
Pictorial View
International5
To the best of our knowledge the information contained in this brochure, is accurate at the time of going to print and the company reserves the right to improve or modify any product illustrated without notification. The company is unable to accept liability for any inaccuracies, errors or omissions that may exist. It is the customer's responsibility to ensure that the product is suitable for their application.
All copyright reserved-Hawke Cable Glands Ltd 2001.This document and all copyright therein is the property of: Hawke International a trading name of Hawke Cable GlandsLtd (A member of the McKechnie Group of Companies).Copyright Condition: This document shall be used only for the purpose for which it is provided and no reproduction or publication of the document may be made and no article may be manufactured or assembled in accordance with information contained in the document without prior written consent of the owner.
Smarter productswww.ehawke.com
Cable GlandType
Certification
CertificationOptions
IngressProtection
Sealing
Application/Cable Type
121
351/RAC
501/453ICG 653
153Sizes G, H & J
CSB 656 IP66/67/68Deluge
IP66/67/68(Delugeoption)
IP66(Delugeoption)
IP66(Delugeoption)
IP66/67/68Deluge
IP66/67/68Deluge
IP66/67/68Deluge
Dry Indoor/outdoorArmoured/braided cable with
inner (optional) and outer sheath
Indoor/outdoorArmoured/braided cable with
inner (optional) and outer sheath
Indoor/outdoorArmoured/braided cable with
inner and outer sheath
Individualconductor
seal
Individualconductor
(compound) seal
Outer cable sheath seal
Inner and outer cable sheath seals
Outer cable sheath seal
Indoor/outdoorIndividual conductors,
conduit system
Indoor/outdoorIndividual conductors,
conduit system
Indoor/outdoorArmoured/braided cable with
inner (optional) and outer sheath
SB 47417
18
19
20
21
22
23
24
25
26
27
150/RAC
151/RAC
123
ATEXEExd IIC/EExe II
Zone 1, 2, 21 & 22II 2 GD
ATEXEExe II
Zone 1, 2, 21 & 22II 2 GD
EN 50262
EN 50262
BS 6121
EN 50262
EN 50262
EN 50262
EN 50262
IEC
IEC
IEC
IEC
IEC
IEC
IEC
IEC
IEC
IEC
Indoor/outdoorNon-armoured cable
Indoor/outdoorNon-armoured cable
IP66/67/68Deluge
IP66/67(Delugeoption)
IP66/67(Delugeoption)
Indoor/outdoorArmoured/braided cable
with inner and outer cable sheath
Inner (diaphragm) and outer
cable sheath seal
Outer cable sheath seal
Indoor/outdoorNon-armoured cable,
conduit system 114
153/RAC
153/RAC/L
Outer cable sheath seal
Two outer cable sheath seals
Indoor/outdoorArmoured/braided cable with
inner lead sheath and outer sheath
Inner seal/lead sheath electrical bond and outer
cable sheath seal
IEC
ATEXEExd IIC/EExe II
Zone 1, 2, 21 & 22II 2 GD
ATEXEExd IIC/EExe II
Zone 1, 2, 21 & 22II 2 GD
Cable Gland Selection Chart
ATEXEExd IIC/EExe II
Zone 1, 2, 21 & 22II 2 GD
IEC
To the best of our knowledge the information contained in this brochure, is accurate at the time of going to print and the company reserves the right to improve or modify any product illustrated without notification. The company is unable to accept liability for any inaccuracies, errors or omissions that may exist. It is the customer's responsibility to ensure that the product is suitable for their application.
All copyright reserved-Hawke Cable Glands Ltd 2001.This document and all copyright therein is the property of: Hawke International a trading name of Hawke Cable GlandsLtd (A member of the McKechnie Group of Companies).Copyright Condition: This document shall be used only for the purpose for which it is provided and no reproduction or publication of the document may be made and no article may be manufactured or assembled in accordance with information contained in the document without prior written consent of the owner.
International
Cable GlandType
Certification
IngressProtection
Sealing
Application/Cable Type
755
753
711
710
70128
29
30
31
32
33 - 36
33 - 36
33 - 36
37
38
IP66/67/68Deluge
IP66/67/68Deluge
IP66/67/68Deluge
IP66/67/68(Delugeoption)
IP66/67/68(Delugeoption)
IP66/67/68(Delugeoption)
Indoor/outdoor
Inner (compound) and outer cable
jacket seals
Inner (compound) and outer cable
jacket seals
Inner (compound) and outer cable
jacket seals
Inner (compound) and outer cable
jacket seals
Outer cablejacket seal
Indoor/outdoorType MC and Teck cables
Indoor/outdoorNon-armored cable
Indoor/outdoorType MC and Teck cables
Indoor/outdoorArmored/braided cable with
inner (option) and outer jacket
Indoor/outdoorArmored MarineShipboard cable
Adaptors/Reducers
Cable GlandVariations& Options
Accessories
Accessories
Accessories
UL/cULUL 514B
UL/cULClass 1 Division 1
Groups A, B, C & D
UL/cULClass 1 Division 1
Groups A, B, C & D
UL/cULClass 1 Division 2
Groups A, B, C & D
UL/cULClass 1 Division 2
Groups A, B, C & D
Colour Coded
CataloguePage No.
Pictorial View
CertificationOptions
C
C
C
C
C
6
Smarter productswww.ehawke.com
Application
Function
'G' Approx15.0mm
MetricEntry
'B
'
Entr
y Thr
ead
Outdoor or Indoor use. For use with non-armoured elastomer and plastic insulated cables. See technical section of catalogue for installation rules and regulations.
Provides a high pullout resistant seal onto the cables outer sheath. When used in increased safety applications, this cable gland may be used with braided cable where the braid and the cables outer sheath pass into the enclosure. The braid must be suitably terminated into the enclosure.
ATEX Cable Gland Ordering ExamplesCable Gland Type/Size/Thread e.g. 501/421/C/M32 501/421/C/1" NPT
Flameproof and Increased Safety
501/421 Cable Gland Type
ATEX
International7
Smarter productswww.ehawke.com
Materials & FinishesHawke cable glands are manufactured as standard in brass.Alternative materials and plating are available.
Technical Data Flameproof EExd and Increased Safety EExe. II 2 GD BASEEFA Certificate No. BAS 01 ATEX 2070X. For sizes Os - F. BASEEFA Certificate No. BAS 01 ATEX 2294X. For sizes G - J. Suitable for use in Zone 1, Zone 2, Zone 21 and Zone 22. Suitable for use in Gas Groups IIA, IIB and IIC.
IP66, IP67 and IP68 ingress protection to IEC 60529, EN 60529 and NEMA 4X. DTS01 deluge protection certified by ITS. Operating temperature range -60C to +80C as standard. Option available, Exd IIC, Exe II.
Construction and test standards EN 50014, EN 50018, EN 50019 and EN 50281-1-1.IEC 60079-0, IEC 60079-1 and IEC 60079-7.
Option available, BR-Exd IIC/Exe II.certificate No. Ex-017/2001X.
Alternative thread sizes available. See page 38 Accessories including locknuts, sealing washers, shakeproof washers, shrouds, adaptors and reducers available. See pages 33 - 37
All Metric entry threads are 1.5mm pitch medium fit.All dimensions in millimetres (except*). Sizes Os and O are available with an M16 thread size. For O size with M16 thread, the maximum cable outer sheath diameter is 10.9mm.Assembly instruction data sheet No. A.I. 307. For sizes Os to F.Assembly instruction data sheet No. A.I. 326. For sizes G to J.
Cable Gland with Alternative Seal (S)
e.g. 501/421/C/M32/S 501/421/C/1" NPT/S
CABLE GLAND SELECTION TABLE
Entry ThreadSize
Metric
SizeRef.
NPT*
'G'
AcrossFlats
AcrossCorners
HexagonDimensions
OsOABCC2DE
F
HJ
M20M20
M20M25M32M40
M50M63M75M80
M90M100
""
2"
2"3"-
3"4"
3.07.5
11.013.019.025.0
31.542.554.5
8.011.914.320.226.532.5
44.456.368.2
8.59.515.522.027.539.048.5
13.415.421.228.034.846.558.3
24.0383938414342585356565656
24.030.036.046.055.0
65.080.095.0
27.727.734.641.653.163.575.192.4109.6
Min. Max.
Outer Sheath 'B'
Min. Max.
G
Cable Acceptance Details
- -- -
1"1"
""
StandardSeal
AlternativeSeal (S)
- -- -- -
67.067.075.0
73.077.691.6
106.4
115.0127.0
123.0
132.8146.7
To the best of our knowledge the information contained in this brochure, is accurate at the time of going to print and the company reserves the right to improve or modify any product illustrated without notification. The company is unable to accept liability for any inaccuracies, errors or omissions that may exist. It is the customer's responsibility to ensure that the product is suitable for their application.
All copyright reserved-Hawke Cable Glands Ltd 2001.This document and all copyright therein is the property of: Hawke International a trading name of Hawke Cable GlandsLtd (A member of the McKechnie Group of Companies).Copyright Condition: This document shall be used only for the purpose for which it is provided and no reproduction or publication of the document may be made and no article may be manufactured or assembled in accordance with information contained in the document without prior written consent of the owner.
Technical Data Flameproof EExd and Increased Safety EExe. II 2 GD BASEEFA Certificate No. BAS 01 ATEX 2071X. For sizes Os - F. BASEEFA Certificate No. BAS 01 ATEX 2295X. For sizes G - J. Suitable for use in Zone 1, Zone 2, Zone 21 and Zone 22. Suitable for use in Gas Groups IIA, IIB and IIC.
IP66, IP67 and IP68 ingress protection to IEC 60529, EN 60529 and NEMA 4X. DTS01 deluge protection certified by ITS. Additional deluge protection seal also available. Operating temperature range -60C to +80C as standard. Option available, Exd IIC, Exe II.
Construction and test standards EN 50014, EN 50018, EN 50019 and EN 50281-1-1.IEC 60079-0, IEC 60079-1 and IEC 60079-7.
8
To the best of our knowledge the information contained in this brochure, is accurate at the time of going to print and the company reserves the right to improve or modify any product illustrated without notification. The company is unable to accept liability for any inaccuracies, errors or omissions that may exist. It is the customer's responsibility to ensure that the product is suitable for their application.
All copyright reserved-Hawke Cable Glands Ltd 2001.This document and all copyright therein is the property of: Hawke International a trading name of Hawke Cable GlandsLtd (A member of the McKechnie Group of Companies).Copyright Condition: This document shall be used only for the purpose for which it is provided and no reproduction or publication of the document may be made and no article may be manufactured or assembled in accordance with information contained in the document without prior written consent of the owner.
International
Alternative thread sizes available. See page 38 Accessories including locknuts, sealing washers, shakeproof washers, shrouds, adaptors and reducers available. See pages 33 - 37
All Metric entry threads are 1.5mm pitch medium fit.All dimensions in millimetres (except*). Sizes Os and O are available with an M16 thread size. For O size with M16 thread, the maximum cable outer sheath diameter is 10.9mm.Assembly instruction data sheet No. A.I. 306. For sizes Os to F.Assembly instruction data sheet No. A.I. 334. For sizes G to J.
ATEX Cable Gland Ordering ExamplesCable Gland Type/Size/Thread e.g. 501/423/C/M32 501/423/C/1" NPT
Cable Gland with Alternative Seal (S)
e.g. 501/423/C/M32/S 501/423/C/1" NPT/S
CABLE GLAND SELECTION TABLE
Entry ThreadSize
Metric
SizeRef.
NPT*
'G'
AcrossFlats
AcrossCorners
HexagonDimensions
OsOA
BCC2DEF
HJ
M20M20
M20
M25M32M40M50M63
M75M80M90M100
""
2"2"3"-
3"
4"
3.07.5
11.0
13.019.025.031.542.554.567.067.0
75.0
73.077.691.6
8.011.914.320.226.532.544.456.368.2
8.59.5
15.522.027.539.048.5
13.415.421.228.0
34.846.558.3
24.067686469727310098100
100100100
24.030.0
36.046.0
55.065.080.095.0
27.727.734.6
41.653.1
63.575.192.4109.6
106.4115.0127.0
123.0132.8146.7
Min. Max.
Outer Sheath 'B'
Min. Max.
G
Cable Acceptance Details
- -- -
1"1"
""
StandardSeal
AlternativeSeal (S)
- -- -- -
'G' Approx15.0mm
'B
'
Entr
y Thr
ead
MetricEntry
Smarter productswww.ehawke.com
Flameproof and Increased Safety
501/423 Cable Gland Type
ATEX
Application
Function
Materials & FinishesHawke cable glands are manufactured as standard in brass.Alternative materials and plating are available.
Outdoor or Indoor use. For use with non-armoured elastomer and plastic insulated cables. May be used on cables incorporating inner and outer cable sheaths. See technical section of catalogue for installation rules and regulations. Provides a high pullout resistant seal onto the cables outer sheath at two independent sealing points. When used in increased safety applications, this cable gland may be used with braided cable where the braid and the cables outer sheath pass into the enclosure. The braid must be suitably terminated inside the enclosure.
Armour/Braid'C'
Technical Data
Function
Application
Materials & Finishes
Outdoor or Indoor use. For use with single wire armoured 'W', wire braided 'X' and steel tape armoured 'Z' elastomer and plastic insulated cables.
Flameproof EExd and Increased Safety EExe. II 2 GD BASEEFA Certificate No. BAS 01 ATEX 2072X. For sizes Os - F. BASEEFA Certificate No. BAS 01 ATEX 2296X. For sizes G - J. Suitable for use in Zone 1, Zone 2, Zone 21 and Zone 22. Suitable for use in Gas Groups IIA, IIB and IIC.
IP66, IP67 and IP68 ingress protection to IEC 60529, EN 60529 and NEMA 4X. Operating temperature range -60C to +80C as standard. Option available, Exd IIC, Exe II.
Provides armour clamping using one clamping arrangement for all armour/braid types 'W', 'X' and 'Z'. Provides a seal on the cables inner sheath. Deluge protection option available.
Hawke cable glands are manufactured as standard in brass.Alternative materials and plating are available.
Construction and test standards EN 50014, EN 50018, EN 50019 and EN 50281-1-1.IEC 60079-0, IEC 60079-1 and IEC 60079-7.
See technical section of catalogue for installation rules and regulations.
Provides a high pullout resistance and low smoke and fume, zero halogen seal onto the cables outer sheath.
Alternative thread sizes available. See page 38 Alternative non-standard armour clamping rings available. See page 38Accessories including locknuts, sealing washers, shakeproof washers, earth tags, shrouds, adaptors and reducers available. See pages 33 - 37
All Metric entry threads are 1.5mm pitch medium fit.All dimensions in millimetres (except*). Sizes Os and O are available with an M16 thread size. For O size with M16 thread, the maximum cable inner sheath diameter is 10.9mm.# Dedicated armour clamping rings are fitted. Please specify armour type and size.Assembly instruction data sheet No. A.I. 302. For sizes Os to F.Assembly instruction data sheet No. A.I. 329. For sizes G to J.
ATEX Cable Gland Ordering ExamplesCable Gland Type/Size/Thread e.g. 501/453/RAC/C/M32 501/453/RAC/C/1" NPT
Cable Gland with Alternative Seal (S)
e.g. 501/453/RAC/C/M32/S 501/453/RAC/C/1" NPT/S
International9
Smarter productswww.ehawke.com
To the best of our knowledge the information contained in this brochure, is accurate at the time of going to print and the company reserves the right to improve or modify any product illustrated without notification. The company is unable to accept liability for any inaccuracies, errors or omissions that may exist. It is the customer's responsibility to ensure that the product is suitable for their application.
All copyright reserved-Hawke Cable Glands Ltd 2001.This document and all copyright therein is the property of: Hawke International a trading name of Hawke Cable GlandsLtd (A member of the McKechnie Group of Companies).Copyright Condition: This document shall be used only for the purpose for which it is provided and no reproduction or publication of the document may be made and no article may be manufactured or assembled in accordance with information contained in the document without prior written consent of the owner.
CABLE GLAND SELECTION TABLE
Entry ThreadSize Standard
SealAlternative
Seal (S)
Outer Sheath'B'
Inner Sheath 'A'
Metric
SizeRef.
NPT*
'G'AcrossFlats
AcrossCorners
HexagonDimensions
OsOABCC2DE
F
H J
M20M20
M20M25M32M40
M50M63M75
M80M90M100
""
2"2"3"
-
3"4"
3.07.5
11.013.019.025.0
31.542.554.5
11.914.320.226.532.5
44.456.368.2
8.59.515.522.027.539.048.5
13.415.421.228.034.846.558.3
24.024.030.036.046.055.065.080.095.0
27.727.734.641.653.163.575.192.4109.6
Min. Max. Min. Min.Max. Max.
G
Cable Acceptance Details
8.0
12.516.922.028.036.046.057.0
20.526.033.041.052.665.378.0
5.5 12.09.5 16.0
0.9/1.250.9/1.250.9/1.251.25/1.61.6/2.01.6/2.01.8/2.51.8/2.51.8/2.5
0/0.70/0.70/0.70/0.70/0.70/0.70/1.00/1.00/1.0
Larger cable glands available in 501/453 design as shown below. See page 19
1"1"
""
8181
839598105133126
121121121
134
67.067.075.0
73.077.691.6
75.075.088.0
89.589.5
104.5
106.4
115.0127.0
123.0
132.8146.7
###
###
'C'Armour/Braid
Orientation2
Orientation1
- -- -- -
- -- -
'A
'
Entr
y Thr
ead
'G' Approx
MetricEntry
'B
'
15.0mm
Flameproof and Increased Safety
501/453/RAC Cable Gland Type
ATEX
Armour/Braid'C'
'B
'
'A
'
Entr
y Thr
ead
MetricEntry
Lead Sheath Bond
15.0mm 'G' Approx
ATEX Cable Gland Ordering ExampleCable Gland Type/Size/Thread/Standard Inner Seal + Bond e.g. 501/453/RAC/C/M32/L 501/453/RAC/C/1" NPT/L
Application
Function
Technical Data
Outdoor or Indoor use. For use with single wire armoured 'W', wire braided 'X' and steel tape armoured 'Z' cables with a lead inner sheath. See technical section of catalogue for installation rules and regulations Provides armour clamping using one clamping arrangement for all armour/braid types 'W', 'X' and 'Z'. Provides a seal and an electrical bond on the cables lead inner sheath. Provides a high pullout resistance and low smoke and fume, zero halogen seal onto the cables outer sheath.
Deluge protection option available.
Materials & FinishesHawke cable glands are manufactured as standard in brass.Alternative materials and plating are available.
IP66, IP67 and IP68 ingress protection to IEC 60529, EN 60529 and NEMA 4X. Operating temperature range -60C to +80C as standard.
Zone 21 and Zone 22.Suitable for use in Gas GroupsIIA, IIB and IIC.Construction and test standards EN 50014, EN 50018, EN 50019 and EN 50281-1-1.IEC 60079-0, IEC 60079-1 and IEC 60079-7.
Flameproof EExd IIC and Increased Safety EExe II. II 2 GD BASEEFA Certificate No. BAS 01 ATEX 2072X. Fos sizes O - F. BASEEFA Certificate No. BAS 01 ATEX 2296X. For sizes G - J. Suitable for use in Zone 1, Zone 2
Flameproof and Increased Safety
501/453/RAC/L Cable Gland Type
International10
To the best of our knowledge the information contained in this brochure, is accurate at the time of going to print and the company reserves the right to improve or modify any product illustrated without notification. The company is unable to accept liability for any inaccuracies, errors or omissions that may exist. It is the customer's responsibility to ensure that the product is suitable for their application.
All copyright reserved-Hawke Cable Glands Ltd 2001.This document and all copyright therein is the property of: Hawke International a trading name of Hawke Cable GlandsLtd (A member of the McKechnie Group of Companies).Copyright Condition: This document shall be used only for the purpose for which it is provided and no reproduction or publication of the document may be made and no article may be manufactured or assembled in accordance with information contained in the document without prior written consent of the owner.
Smarter productswww.ehawke.com
ATEX
CABLE GLAND SELECTION TABLE
Entry ThreadSize
Metric
SizeRef.
NPT*
'G'
AcrossFlats
AcrossCorners
HexagonDimensions
OABCC2DE
F
M20
M20M25M32M40
M50M63M75
"
2"
2"3"
11.015.522.027.539.051.0
15.421.228.034.846.558.3
24.030.036.046.055.0
65.080.095.0
27.734.641.653.163.575.192.4109.6
Inner Lead Sheath 'A'Outer Sheath
'B'Alternative Seal + Bond
Max. Max.Min. Max.Min.Min.
Cable Acceptance Details
Alternative thread sizes available. See page 38Alternative non-standard armour clamping rings available. See page 38Accessories including locknuts, sealing washers, shakeproof washers, earth tags, shrouds, adaptors and reducers available. See page 33 - 37
All Metric entry threads are 1.5mm pitch medium fit.All dimensions in millimetres (except*). Size O is available with an M16 thread size. For O size with M16 thread, the maximum cable inner sheath diameter is 10.9mm.# Dedicated armour clamping rings are fitted. Please specify armour type and size.Assembly instruction data sheet No. A.I. 302 + 336. For sizes O to F.Assembly instruction data sheet No. A.I. 329 + 336. For sizes G to J.
1"1"
""
H J
M80M90M100
- - -- -- -
3"4"
G
Larger cable glands available in 501/453/L design as shown below.
121
81839598
105133126134
121121
59.968.979.4
68.573.187.1
75.075.088.0
89.589.5104.5
106.4
115.0127.0
123.0
132.8146.7
Cable Gland with Alternative Inner Seal + Bond
e.g. 501/453/RAC/C/M32/K 501/453/RAC/C/1" NPT/K
###
###
'C'Armour/Braid
Orientation2
Orientation1
12.516.922.028.036.046.057.0
20.526.033.041.052.665.378.0
9.5 16.0 0.9/1.250.9/1.251.25/1.61.6/2.01.6/2.01.8/2.51.8/2.51.8/2.5
0/0.70/0.70/0.70/0.70/0.70/1.00/1.00/1.0
8.513.019.025.031.542.054.5
10.8
16.722.528.540.352.063.8
7.5 8.5 - -- -
Standard Seal + Bond
Technical Data
Function
Application
Materials & Finishes
'A
'
Entr
y Thr
ead
'G' Approx15.0mm
MetricEntry
DelugeBoot
DiaphragmSeal
Armour/Braid'C'
'B
'
Outdoor or Indoor use. For use with single wire armoured 'W', wire braided 'X' and steel tape armoured 'Z' elastomer and plastic insulated cables. Suitable for use with cables that exhibit 'cold flow' characteristics.
ATEX Cable Gland Ordering ExamplesCable Gland Type/Size/Thread e.g. 501/453/UNIV/C/M32 501/453/UNIV/C/1" NPT
Flameproof EExd and Increased Safety EExe. II 2 GD BASEEFA Certificate No. BAS 01 ATEX 2078X. For sizes Os - F. BASEEFA Certificate No. BAS 01 ATEX 2296X. For sizes G - J. Suitable for use in Zone 1, Zone 2, Zone 21 and Zone 22. Suitable for use in Gas Groups IIA, IIB and IIC.
IP66, IP67 and IP68 ingress protection to IEC 60529, EN 60529 and NEMA 4X. DTS01 deluge protection certified by ITS. Operating temperature range -60C to +80C as standard. Option available, Exd IIC, Exe II.
Provides armour clamping using one clamping arrangement for all armour/braid types 'W', 'X' and 'Z'. Provides a diaphragm seal on the cables inner sheath. A diaphragm seal will not damage cable that has 'cold flow' characteristics. Provides an outer deluge seal to prevent moisture ingress to the cable armour/braid.
Hawke cable glands are manufactured as standard in brass.Alternative materials and plating are available.
Construction and test standards EN 50014, EN 50018, EN 50019 and EN 50281-1-1.IEC 60079-0, IEC 60079-1 and IEC 60079-7.
See technical section of catalogue for installation rules and regulations.
Option available, BR-Exd IIC/Exe II.certificate No. Ex-017/2001X.
Provides a high pullout resistance and lowsmoke and fume, zero halogen seal onto thecables outer sheath.
Flameproof and Increased Safety
501/453/UNIV Cable Gland Type
ATEX
International11
Smarter productswww.ehawke.com
To the best of our knowledge the information contained in this brochure, is accurate at the time of going to print and the company reserves the right to improve or modify any product illustrated without notification. The company is unable to accept liability for any inaccuracies, errors or omissions that may exist. It is the customer's responsibility to ensure that the product is suitable for their application.
All copyright reserved-Hawke Cable Glands Ltd 2001.This document and all copyright therein is the property of: Hawke International a trading name of Hawke Cable GlandsLtd (A member of the McKechnie Group of Companies).Copyright Condition: This document shall be used only for the purpose for which it is provided and no reproduction or publication of the document may be made and no article may be manufactured or assembled in accordance with information contained in the document without prior written consent of the owner.
CABLE GLAND SELECTION TABLE
Entry ThreadSize
Metric
SizeRef.
NPT*
'G'
AcrossFlats
AcrossCorners
HexagonDimensions
OsOABCC2DE
F
H J
M20M20
M20M25M32M40
M50M63M75
M80M90M100
""
1"1"
2"2"3"
-
3"4"
3.07.59.412.117.623.1
28.939.950.5
8.111.914.320.226.532.5
44.456.368.2
12.516.922.028.036.046.057.0
20.526.033.041.052.665.378.0
24.024.030.036.046.055.0
65.080.095.0
27.727.734.641.653.163.575.192.4109.6
Inner Sheath'A'
Min. Max.
Outer Sheath'B'
Min. Max.
G
Cable Acceptance Details
5.5 12.09.5 16.0
103
0.9/1.250.9/1.250.9/1.251.25/1.61.6/2.01.6/2.01.8/2.51.8/2.51.8/2.5
0/0.70/0.70/0.70/0.70/0.7
0/0.70/1.00/1.00/1.0
878789
100
110133134140
Alternative thread sizes available. See page 38 Alternative non-standard armour clamping rings available. See page 38Accessories including locknuts, sealing washers, shakeproof washers, earth tags, shrouds, adaptors and reducers available. See pages 33 - 37
All Metric entry threads are 1.5mm pitch medium fit.All dimensions in millimetres (except*). Sizes Os and O are available with an M16 thread size. For O size with M16 thread, the maximum cable inner sheath diameter is 10.9mm.# Dedicated armour clamping rings are fitted. Please specify armour type and size.Assembly instruction data sheet No. A.I. 300. For sizes Os to F.Assembly instruction data sheet No. A.I. 329. For sizes G to J.
Larger cable glands available in 501/453 design as shown below. See page 19
""
121121121
67.067.075.0
73.077.691.6
75.075.088.0
89.589.5104.5
106.4
115.0127.0
123.0
132.8146.7
#
##
#
##
'C'Armour/Braid
Orientation2
Orientation1
Materials & Finishes
Technical Data
'G' Approx15.0mm
MetricEntry
Entr
y Thr
ead
'B
'
ATEX Cable Gland Ordering ExamplesCable Gland Type/Size/Thread e.g. PSG 553/RAC/C/M32 PSG 553/RAC/C/1" NPT
The required number of holes for the cores are punched in the seal by means of a special tool to suit the core size.
Hawke cable glands are manufactured as standard in brass.Alternative materials and plating are available.
Flameproof EExd and Increased Safety EExe. II 2 GD BASEEFA Certificate No. BAS 01 ATEX 2074X. Suitable for use in Zone 1, Zone 2, Zone 21 and Zone 22. Suitable for use in Gas Groups IIA, IIB and IIC.
IP66, IP67 and IP68 ingress protection to IEC 60529 and EN 60529. Operating temperature range -60C to +80C as standard.
Construction and test standards EN 50014, EN 50018, EN 50019 and EN 50281-1-1.IEC 60079-0, IEC 60079-1 and IEC 60079-7.
Armour/Braid'C'
Provides a high pullout resistance and low smoke and fume, zero halogen seal onto the cables outer sheath.
Flameproof and Increased Safety
ATEXPSG 553/RAC
Cable Gland Type
International12
Smarter productswww.ehawke.com
Application
Function
Outdoor or Indoor use. For use with single wire armoured 'W', wire braided 'X' and steel tape armoured 'Z' elastomer and plastic insulated cables. For particular use with :- Cables that are not substantially compact and circular, have extruded bedding and the fillers, if any, are hygroscopic (eg. not effectively filled).b) Cables that exhibit "Cold Flow"characteristics. See technical section of catalogue for installation rules and regulations.
Provides armour clamping using one clamping arrangement for all armour/braid types 'W', 'X' and 'Z'.
a)
Provides a barrier seal between the individual insulated cores within the cable and prevententry of the products of an explosion intothe cable.
Deluge protection option available.
Alternative thread sizes available. See page 38Alternative non-standard armour clamping rings available. See page 38Accessories including locknuts, sealing washers, shakeproof washers, earth tags, shrouds, adaptors and reducers available. See pages 33 - 37
All Metric entry threads are 1.5mm pitch medium fit.All dimensions in millimetres (except*).Assembly instruction data sheet No. A.I. 312.
CABLE GLAND SIZE FOR CORE SIZE & NUMBER
Maximum No.of Cores
A & B743
1.5 2.5
Cores Cross Sectional Area mm
4.0 6.0 10.0
---
---
--
PUNCH TOOL SIZE DETAILSPunch Ref.
Core C.S.A. mmNo.1 No.1 No.2 No.2 No.31.5 2.5 4.0 6.0 10.0
A & B B & C C B
C
B
CABLE GLAND SELECTION TABLE
Entry ThreadSize
Metric
SizeRef.
NPT*
'G'
AcrossFlats
AcrossCorners
HexagonDimensions
ABC
M20M25M32
12.516.922.0
20.526.033.0
30.036.046.0
34.641.653.1
Outer Sheath'B'
Min. Max.
Cable Acceptance Details
0.9/1.251.25/1.61.6/2.0
0/0.70/0.70/0.71"
""
8899101
Punch Tool Ordering Example e.g. Punch Tool Number 1.
'C'Armour/Braid
Orientation2
Orientation1
To the best of our knowledge the information contained in this brochure, is accurate at the time of going to print and the company reserves the right to improve or modify any product illustrated without notification. The company is unable to accept liability for any inaccuracies, errors or omissions that may exist. It is the customer's responsibility to ensure that the product is suitable for their application.
All copyright reserved-Hawke Cable Glands Ltd 2001.This document and all copyright therein is the property of: Hawke International a trading name of Hawke Cable GlandsLtd (A member of the McKechnie Group of Companies).Copyright Condition: This document shall be used only for the purpose for which it is provided and no reproduction or publication of the document may be made and no article may be manufactured or assembled in accordance with information contained in the document without prior written consent of the owner.
Application
Technical Data
Materials & Finishes
Function
'G' Approx15.0mm
MetricEntry
'B
'
'D
'
Entr
y Thr
ead
'E
'
InspectableCompound
Outdoor or Indoor use. For use with non-armoured elastomer and plastic insulated cables.For particular use with :- Cables that are not substantially compact and circular, have extruded bedding and the fillers, if any, are hygroscopic (eg. not effectively filled).b) Enclosures containing an ignition source in gas group II C areas.c) Enclosures exceeding 2 litres in volume, containing an ignition source and installed in a Zone 1 area.d) Cables that exhibit "Cold Flow" characteristics. See technical section of catalogue for installation rules and regulations.
ATEX Cable Gland Ordering ExamplesCable Gland Type/Size/Thread e.g. ICG 623/C/M32 ICG 623/C/1" NPT
IP66, IP67 and IP68 ingress protection to IEC 60529, EN 60529 and NEMA 4X. DTS01 deluge tested by ITS. Operating temperature range -60C to +80C as standard. Option available, Exd IIC, Exe II.
Hawke cable glands are manufactured as standard in brass.Alternative materials and plating are available.
Flameproof EExd and Increased Safety EExe. II 2 GD BASEEFA Certificate No. BAS 01 ATEX 2079X. Suitable for use in Zone 1, Zone 2, Zone 21 and Zone 22. Suitable for use in Gas Groups IIA, IIB and IIC.
Construction and design standards EN 50014, EN 50018, EN 50019 and EN 50281-1-1.IEC 60079-0, IEC 60079-1 and IEC 60079-7.
Cable Gland with Alternative Seal (S)
e.g. ICG 623/C/M32/S ICG 623/C/1" NPT/S
The compound chamber may be seperated from the compound to ensure that the chamber has been effectively filled.
Two part sealing compound and assembly instructions are supplied with the cable gland.
Provides a high pullout resistance and low smoke and fume, zero halogen seal onto the cables outer sheath.
Provides a barrier seal between the individual insulated cores within the cable and prevent entry of the products of an explosion into the cable.Assembly of the cable gland compresses and distributes the compound evenly toeffect a barrier seal at the point of entryinto the enclosure.
Flameproof and Increased Safety
ICG 623 Cable Gland Type
ATEX
International13
Smarter productswww.ehawke.com
a)
CABLE GLAND SELECTION TABLE
Entry ThreadSize
Metric
SizeRef.
NPT*
'G'AcrossFlats
AcrossCorners
HexagonDimensions
OABCC2DE
F
M20M20M25M32M40
M50M63M75
"
1"1"2"
2"3"
11.016.221.926.337.1
47.859.0
12.518.424.729.741.7
53.566.2
24.06969
69717778959698
30.036.046.055.0
65.080.095.0
27.734.641.653.163.575.192.4109.6
Inner Sheath/Cores
Outer Sheath 'B'
Max.
Cable Acceptance Details
'D' 'E'
8.9 10.0 61021426080
100120
Min. Max. Min.
StandardSeal
AlternativeSeal (S)
7.511.013.019.025.0
31.542.554.5
11.914.320.226.532.5
44.456.368.2
8.59.515.522.027.539.048.5
13.415.421.228.034.846.558.3
- -- -
Alternative thread sizes available. See page 38Accessories including locknuts, sealing washers, shakeproof washers, shrouds, adaptors and reducers available.See pages 33 - 37
All Metric entry threads are 1.5mm pitch medium fit.All dimensions in millimetres (except*).
Assembly instruction data sheet No. A.I. 305.
""
Max.OverCores
Max.Inner
Sheath
Max.No.Of
Cores
Os M20 " 8.0 8.0 8.03.0 24.0 27.76
To the best of our knowledge the information contained in this brochure, is accurate at the time of going to print and the company reserves the right to improve or modify any product illustrated without notification. The company is unable to accept liability for any inaccuracies, errors or omissions that may exist. It is the customer's responsibility to ensure that the product is suitable for their application.
All copyright reserved-Hawke Cable Glands Ltd 2001.This document and all copyright therein is the property of: Hawke International a trading name of Hawke Cable GlandsLtd (A member of the McKechnie Group of Companies).Copyright Condition: This document shall be used only for the purpose for which it is provided and no reproduction or publication of the document may be made and no article may be manufactured or assembled in accordance with information contained in the document without prior written consent of the owner.
Application
Function
Materials & Finishes
Technical Data
Provides an outer deluge seal to prevent moisture ingress to the cable armour/braid.
Provides a high pullout resistance and lowsmoke and fume, zero halogen seal onto the cables outer sheath.
effect a barrier seal at the point of entryinto the enclosure. The compound chamber may be seperated from the compound to ensure that the chamber has been effectively filled.
Assembly of the cable gland compresses and distributes the compound evenly to
Two part sealing compound and assemblyinstructions are supplied with the cablegland.
Provides armour clamping, using one clamping arrangement for all armour/braid types ' W', 'X' and 'Z'.
'G' Approx15.0mm
MetricEntry
DelugeBoot
'B
'
Armour/Braid'C'
'D
'
Entr
y Thr
ead
'E
'
InspectableCompound
Outdoor or Indoor use. For use with single wire armoured 'W', wire braided 'X' and steel tape armoured 'Z' elastomer and plastic insulated cables.For particular use with :- Cables that are not substantially compact and circular, have extruded bedding and the fillers, if any, are hygroscopic (eg. not effectively filled).b) Enclosures containing an ignition source in gas group II C areas.c) Enclosures exceeding 2 litres in volume, containing an ignition source and installed in a Zone 1 area.d) Cables that exhibit "Cold Flow"characteristics. See technical section of catalogue for installation rules and regulations.
Provides a barrier seal between the individual insulated cores within the cable and prevent entry of the products of an explosion into the cable.
ATEX Cable Gland Ordering ExamplesCable Gland Type/Size/Thread
e.g. ICG 653/UNIV/C/M32 ICG 653/UNIV/C/1" NPT
Flameproof EExd and Increased Safety EExe. II 2 GD BASEEFA Certificate No. BAS 01 ATEX 2080X. For sizes Os - F. BASEEFA Certificate No. BAS 01 ATEX 2297X. For sizes G - J. Suitable for use in Zone 1, Zone 2, Zone 21 and Zone 22. Suitable for use in Gas Groups IIA, IIB and IIC.
IP66, IP67 and IP68 ingress protection to IEC 60529, EN 60529 and NEMA 4X. DTS01 deluge protection certified by ITS. Operating temperature range -60C to +80C as standard. Option available, Exd IIC, Exe II.
Construction and test standards EN 50014, EN 50018, EN 50019 and EN 50281-1-1.IEC 60079-0, IEC 60079-1 and IEC 60079-7.
Hawke cable glands are manufactured as standard in brass.Alternative materials and plating are available.
Flameproof and Increased Safety
ICG 653/UNIV Cable Gland Type
ATEX
International14
Smarter productswww.ehawke.com
a)
CABLE GLAND SELECTION TABLE
Entry ThreadSize
Metric
SizeRef.
NPT*
'G'AcrossFlats
AcrossCorners
HexagonDimensions
OOs
ABCC2DE
F
H J
M20M20M25M32M40
M50M63M75
M80M90M100
"M20 "
2"
2"3"
-
3"4"
11.016.221.926.337.1
47.859.0
62.870.980.3
74.083.093.0
12.518.424.729.741.7
53.366.2
24.030.036.046.055.0
65.0
80.095.0
27.734.641.653.163.575.1
92.4109.6
106.4115.0127.0
123.0132.8146.7
Inner Sheath/Cores
Outer Sheath 'B'
G
Cable Acceptance Details
8724.0 27.787
89100
110133
Alternative thread sizes available. See page 38 Accessories including locknuts, sealing washers, shakeproof washers, earth tags, shrouds, adaptors and reducers available. See pages 33 - 37
All Metric entry threads are 1.5mm pitch medium fit.All dimensions in millimetres (except*).# Dedicated armour clamping rings are fitted. Please specify armour type and size.
Assembly instruction data sheet No. A.I. 301. For sizes Os to F.Assembly instruction data sheetNo. A.I. 327. For sizes G to J.
Larger cable glands available in ICG 653 design as shown below. See page 19
'D' 'E'
8.9 10.0 68.9 10.0 6
1021426080
100120
140160180
Min. Max.
9.512.516.922.028.036.046.057.0
75.075.088.0
89.589.5104.5
16.05.5 12.0
20.526.033.041.052.6
65.378.0
0.9/1.250.9/1.251.25/1.61.6/2.01.6/2.01.8/2.51.8/2.51.8/2.5
0/0.70.9/1.25 0/0.7
0/0.7 0/0.70/0.70/0.70/1.00/1.00/1.0
103
133
133133132
140
""1"
1"
Max.No.Of
Cores
Max.OverCores
Max.Inner
Sheath
###
###
'C'Armour/Braid
Orientation2
Orientation1
To the best of our knowledge the information contained in this brochure, is accurate at the time of going to print and the company reserves the right to improve or modify any product illustrated without notification. The company is unable to accept liability for any inaccuracies, errors or omissions that may exist. It is the customer's responsibility to ensure that the product is suitable for their application.
All copyright reserved-Hawke Cable Glands Ltd 2001.This document and all copyright therein is the property of: Hawke International a trading name of Hawke Cable GlandsLtd (A member of the McKechnie Group of Companies).Copyright Condition: This document shall be used only for the purpose for which it is provided and no reproduction or publication of the document may be made and no article may be manufactured or assembled in accordance with information contained in the document without prior written consent of the owner.
'B
'
'G' Approx
InspectableCompound
'E
'
DelugeBoot
Lead Sheath Bond
Entr
y Thr
ead
15.0mm
MetricEntry
'D
'
ATEX Cable Gland Ordering ExampleCable Gland Type/Size/Thread/Bond
e.g. ICG 653/UNIV/C/M32/L ICG 653/UNIV/C/1" NPT/L
Application
Function
Technical Data
Materials & FinishesHawke cable glands are manufactured as standard in brass.Alternative materials and plating are available.
IP66, IP67 and IP68 ingress protection to IEC 60529, EN 60529 and NEMA 4X. DTS01 deluge protection certified by ITS. Operating temperature range -60C to +80C as standard.
Zone 21 and Zone 22.Suitable for use in Gas Groups IIA, IIB and IIC.Construction and test standards EN 50014, EN 50018, EN 50019 and EN 50281-1-1.IEC 60079-0, IEC 60079-1 and IEC 60079-7.
Flameproof EExd IIC and Increased Safety EExe II. II 2 GD BASEEFA Certificate No. BAS 01 ATEX 2080X. For sizes Os - F. BASEEFA Certificate No. BAS 01 ATEX 2297X. For sizes G - J. Suitable for use in Zone 1, Zone 2
Two part sealing compound and assemblyinstructions are supplied with the cablegland.
Alternative thread sizes available. See page 38 Accessories including locknuts, sealing washers, shakeproof washers, earth tags, shrouds, adaptors and reducers available. See pages 33 - 37
All Metric entry threads are 1.5mm pitch medium fit.All dimensions in millimetres (except*). Sizes Os and O are available with an M16 thread size. For O size with M16 thread,the maximum cable inner sheath diameteris 10.9mm.# Dedicated armour clamping rings are fitted. Please specify armour type and size.
Assembly instruction data sheet No. A.I. 301 + 336. For sizes Os to F.Assembly instruction data sheetNo. A.I. 327 + 336. For sizes G to J.
Flameproof and Increased Safety
ICG 653/UNIV/L Cable Gland Type
effect a barrier seal at the point of entryinto the enclosure. The compound chamber may be seperated from the compound to ensure that the chamber has been effectively filled.
Assembly of the cable gland compresses and distributes the compound evenly to
Provides an outer deluge seal to prevent moisture ingress to the cable armour/braid.
Provides a high pullout resistance and lowsmoke and fume, zero halogen seal onto the cables outer sheath.
Provides armour clamping, using one clamping arrangement for all armour/braid types ' W', 'X' and 'Z'.Provides a seal and an electrical bond onthe cables lead inner sheath.
Outdoor or Indoor use. For use with single wire armoured 'W', wire braided 'X' and steel tape armoured 'Z' elastomer and plastic insulated cables with lead inner sheath.For particular use with :- Cables that are not substantially compact and circular, have extruded bedding and the fillers, if any, are hygroscopic (eg. not effectively filled).b) Enclosures containing an ignition source in gas group II C areas.c) Enclosures exceeding 2 litres in volume, containing an ignition source and installed in a Zone 1 area.d) Cables that exhibit "Cold Flow"characteristics. See technical section of catalogue for installation rules and regulations.
Provides a barrier seal between the individual insulated cores within the cable and prevent entry of the products of an explosion into the cable.
a)
International15
Smarter productswww.ehawke.com
ATEX
CABLE GLAND SELECTION TABLE
Entry ThreadSize
Metric
SizeRef.
NPT*
OABCC2DE
F
M20M20M25M32M40
M50M63M75
"
2"
2"3"
10.816.221.926.3
37.147.859.0
10.816.722.528.5
40.052.063.8
Lead Inner Sheath/Cores
Outer Sheath 'B'
Cable Acceptance Details
'D' 'E'
8.5 8.54.07.4
11.014.021.0
27.039.051.0
61021426080100120
Min. Max.
9.512.516.922.028.036.046.057.0
16.020.526.033.041.052.6
65.378.0
0.9/1.250.9/1.251.25/1.61.6/2.01.6/2.01.8/2.51.8/2.51.8/2.5
0/0.7Os M20 " 8.5 8.54.0 6 5.5 12.0 0.9/1.25 0/0.7
0/0.7 0/0.70/0.70/0.70/1.00/1.00/1.0
""1"
1"
Max.No.Of
Cores
Max.OverCores
Max.Inner
Sheath
Min.Inner
Sheath
H J
M80M90M100
-
3"4"
62.870.980.3
69.078.087.0
60.064.578.5
G
Larger cable glands available in ICG 653/L design as shown below.
140160180
75.075.088.0
89.589.5104.5
###
###
'G'AcrossFlats
AcrossCorners
HexagonDimensions
24.030.036.046.055.0
65.0
80.095.0
27.734.641.653.163.575.1
92.4109.6
8724.0 27.787
89100
110133
103
133
133132
133
140
106.4115.0127.0
123.0132.8146.7
'C'Armour/Braid
Orientation2
Orientation1
To the best of our knowledge the information contained in this brochure, is accurate at the time of going to print and the company reserves the right to improve or modify any product illustrated without notification. The company is unable to accept liability for any inaccuracies, errors or omissions that may exist. It is the customer's responsibility to ensure that the product is suitable for their application.
All copyright reserved-Hawke Cable Glands Ltd 2001.This document and all copyright therein is the property of: Hawke International a trading name of Hawke Cable GlandsLtd (A member of the McKechnie Group of Companies).Copyright Condition: This document shall be used only for the purpose for which it is provided and no reproduction or publication of the document may be made and no article may be manufactured or assembled in accordance with information contained in the document without prior written consent of the owner.
Armour/Braid'C'
Application
Function
Technical Data
Materials & Finishes
'G' Approx15.0mm
MetricEntry
'B
'
Fem
ale
Entr
y Thr
ead
Mal
e En
try T
hrea
d
Outdoor or Indoor use. Provides a seal onto cable at entry to enclosure via conduit. See technical section of catalogue for installation rules and regulations.
ATEX Cable Gland Ordering ExamplesCable Gland Type/Size/Male Thread/Female Thread e.g. 501/414/C/M32/M32 501/414/C/1" NPT/M32
Flameproof EExd and Increased Safety EExe. II 2 GD BASEEFA Certificate No. BAS 01 ATEX 2076X. Suitable for use in Zone 1, Zone 2, Zone 21 and Zone 22. Suitable for use in Gas Groups IIA, IIB and IIC.
IP66, IP67 and IP68 ingress protection to IEC 60529 and EN 60529. Operating temperature range -60C to +80C as standard.
Hawke cable glands are manufactured as standard in brass.Alternative materials and plating are available.
Construction and test standards EN 50014, EN 50018, EN 50019 and EN 50281-1-1.IEC 60079-0, IEC 60079-1 and IEC 60079-7.
Provides a seal onto cables outer sheath. Provides female running coupler for conduit entry.
Cable Gland with Alternative Seal (S)
e.g. 501/414/C/M32/M32/S 501/414/C/1" NPT/M32/S
Flameproof and Increased Safety
501/414 Cable Gland Type
ATEX
International16
Smarter productswww.ehawke.com
CABLE GLAND SELECTION TABLEMale EntryThread Size
Metric
SizeRef. NPT
*
'G'AcrossFlats
AcrossCorners
HexagonDimensions
ABCC2DE
F
M20M25M32M40
M50M63M75
2"
2"3"
11.013.019.025.031.5
42.554.5
14.320.226.532.544.456.368.2
30.036.046.055.0
65.080.095.0
34.669617779105105107
41.653.163.575.192.4109.6
Outer Sheath 'B'
Min. Max.
Alternative thread sizes available. See page 38Accessories including locknuts, sealing washers, shakeproof washers,adaptors and reducers available. See pages 33 - 37
All Metric entry threads are 1.5mm pitch medium fit.All dimensions in millimetres (except*).Assembly instruction data sheet No. A.I. 310.
1"1"
""
Female EntryThread Size
Metric NPT*
StandardSeal
AlternativeSeal (S)
8.59.515.522.027.539.048.5
13.415.421.228.034.8
46.558.3
Min. Max.
M20M25M32M40
M50M63M75
-------
To the best of our knowledge the information contained in this brochure, is accurate at the time of going to print and the company reserves the right to improve or modify any product illustrated without notification. The company is unable to accept liability for any inaccuracies, errors or omissions that may exist. It is the customer's responsibility to ensure that the product is suitable for their application.
All copyright reserved-Hawke Cable Glands Ltd 2001.This document and all copyright therein is the property of: Hawke International a trading name of Hawke Cable GlandsLtd (A member of the McKechnie Group of Companies).Copyright Condition: This document shall be used only for the purpose for which it is provided and no reproduction or publication of the document may be made and no article may be manufactured or assembled in accordance with information contained in the document without prior written consent of the owner.
Application
Function
Technical Data
Materials & Finishes
'G' Approx15.0mm
MetricEntry
Mal
e En
try T
hrea
d
Fem
ale
Entr
y Thr
ead
Outdoor or indoor use. For particular use with :- Cables that are not substantially compact and circular, have extruded bedding and the fillers, if any, are hygroscopic (eg. not effectively filled).b) Cables that exhibit "Cold Flow"characteristics. See technical section of catalogue for installation rules and regulations.
ATEX Cable Gland Ordering ExamplesCable Gland Type/Size/Male Thread/Female Thread e.g. SB 474/C/M32/M32 SB 474/C/1" NPT/M32
Punch Tool Ordering Example e.g. Punch Tool Number 1.
Flameproof EExd and Increased Safety EExe. II 2 GD BASEEFA Certificate No. BAS 01 ATEX 2077X. Suitable for use in Zone 1, Zone 2, Zone 21 and Zone 22. Suitable for use in Gas Groups IIA, IIB and IIC.
IP66, IP67 and IP68 ingress protection to IEC 60529 and EN 60529. Operating temperature range -60C to +80C as standard.
The required number of holes for the conductors are punched in the seal by means of a special tool to suit the core size. Provides female running coupler for conduit entry.
Hawke cable glands are manufactured as standard in brass.Alternative materials and plating are available.
Construction and test standards EN 50014, EN 50018, EN 50019 and EN 50281-1-1.IEC 60079-0, IEC 60079-1 and IEC 60079-7.
a)
Provides a barrier seal between the individual insulated cores and prevent entry of the products of an explosion into the cable.
Flameproof and Increased Safety
ATEXSB 474
Cable Gland Type
International17
Smarter productswww.ehawke.com
CABLE GLAND SELECTION TABLEMale EntryThread Size
MetricSizeRef. NPT
*
'G'AcrossFlats
AcrossCorners
HexagonDimensions
ABC
M20M25M32
30.036.046.0
34.641.653.1
Alternative thread sizes available. See page 38Accessories including locknuts, sealing washers, shakeproof washers, adaptors and reducers available. See pages 33 - 37
All Metric entry threads are 1.5mm pitch medium fit.All dimensions in millimetres (except*).Assembly instruction data sheet No. A.I. 309.
1"
""
Female EntryThread Size
Metric NPT*
M20M25M32
CABLE GLAND SIZE CORE SIZE & NUMBER
Maximum No.of Cores
A & B743
1.5 2.5
Cores Cross Sectional Area mm
4.0 6.0 10.0
---
---
--
PUNCH TOOL SIZE DETAILSPunch Ref.
Core C.S.A. mmNo.1 No.1 No.2 No.2 No.31.5 2.5 4.0 6.0 10.0
A & B B & C C B
C
B
696177
---
To the best of our knowledge the information contained in this brochure, is accurate at the time of going to print and the company reserves the right to improve or modify any product illustrated without notification. The company is unable to accept liability for any inaccuracies, errors or omissions that may exist. It is the customer's responsibility to ensure that the product is suitable for their application.
All copyright reserved-Hawke Cable Glands Ltd 2001.This document and all copyright therein is the property of: Hawke International a trading name of Hawke Cable GlandsLtd (A member of the McKechnie Group of Companies).Copyright Condition: This document shall be used only for the purpose for which it is provided and no reproduction or publication of the document may be made and no article may be manufactured or assembled in accordance with information contained in the document without prior written consent of the owner.
Application
Function
Technical Data
Materials & Finishes
'G' Approx15.0mm
MetricEntry
Mal
e En
try T
hrea
d
Fem
ale
Entr
y Thr
ead
'D
'
'E
'
To seal conductors at entry to enclosure via conduit or to enable an existing cable gland to be converted to a barrier type cable gland. See technical section of catalogue for installation rules and regulations.
ATEX Cable Gland Ordering ExamplesCable Gland Type/Size/Male Thread/Female Thread e.g. CSB 656/C/M32/M32 CSB 656/C/1" NPT/1" NPT
Flameproof EExd and Increased Safety EExe. II 2 GD BASEEFA Certificate No. BAS 01 ATEX 2082X. Suitable for use in Zone 1, Zone 2, Zone 21 and Zone 22. Suitable for use in Gas Groups IIA, IIB and IIC.
IP66, IP67 and IP68 ingress protection to IEC 60529 and EN 60529. Operating temperature range -60C to +80C as standard.
Hawke cable glands are manufactured as standard in brass.Alternative materials and plating are available.
Construction and test standards EN 50014, EN 50018, EN 50019 and EN 50281-1-1.IEC 60079-0, IEC 60079-1 and IEC 60079-7.
Allen Grub Screw2mm A/F A-C
2.5mm A/F C2-F
Provides a barrier seal between the individual insulated conductors within the cable or conduit and prevent entry of the products of an explosion into the cable or conduit.The device is fitted with a simple compound filled chamber which permits packing aroundindividual insulated conductors.Assembly of the cable gland compresses and distributes the compound evenly toeffect a barrier seal at the point of entryinto the enclosure. The compound chamber may beseperated from the compound to ensure that the chamber has been effectively filled.Provides female running coupler for cablegland or conduit entry.
Two part sealing compound and assembly instructions are supplied with the cable gland.
Flameproof and Increased Safety
ATEXCSB 656
Cable Gland Type
International18
To the best of our knowledge the information contained in this brochure, is accurate at the time of going to print and the company reserves the right to improve or modify any product illustrated without notification. The company is unable to accept liability for any inaccuracies, errors or omissions that may exist. It is the customer's responsibility to ensure that the product is suitable for their application.
All copyright reserved-Hawke Cable Glands Ltd 2001.This document and all copyright therein is the property of: Hawke International a trading name of Hawke Cable GlandsLtd (A member of the McKechnie Group of Companies).Copyright Condition: This document shall be used only for the purpose for which it is provided and no reproduction or publication of the document may be made and no article may be manufactured or assembled in accordance with information contained in the document without prior written consent of the owner.
Smarter productswww.ehawke.com
Outdoor or Indoor use. CABLE GLAND SELECTION TABLE
Male EntryThread Size
Metric
SizeRef. NPT
*
'D' AcrossFlats
AcrossCorners
HexagonDimensions
ABC
DEF
C2
M20M25M32M40M50M63M75
M80M90M100
M80M90M100
M40M50M63M75
30.036.046.0
34.641.653.1
Alternative thread sizes available. See page 38Accessories including locknuts, sealing washers, shakeproof washers, adaptors and reducers available. See pages 33 - 37
All Metric entry threads are 1.5mm pitch medium fit.All dimensions in millimetres (except*).
Assembly instruction data sheet No. A.I. 311. For sizes A to F.Assembly instruction data sheet No. A.I. 328. For sizes G to J.
1"1"2"
2"3"
1"2"
2"3"
""
Female EntryThread Size
Metric NPT*
M20M25M32 1"
""
Inner Sheath/Cores
Max.OverCores
'E'Max.Inner
Sheath
Max.No.Of
Cores
'G'
55.065.080.095.0
11.016.221.926.337.147.859.062.870.980.3
74.083.093.0
12.518.424.7
29.741.753.566.2
1021426080100120140160180
56585864646468707070
63.575.192.4
109.6
H J
G -
3"4"
-
3"4"
106.4115.0127.0
123.0132.8146.7
Inspectable Compound
501/453 Flameproof / Increased Safety
ICG 653 Flameproof / Increased Safety
153 Industrial general purpose
Armour/Braid'C'
'B
'
'A
'
Entr
y Thr
ead
15.0mm
MetricEntry
Armour/Braid'C'
'B
'
15.0mm
MetricEntry
Armour/Braid'C'
'B
'
'A
'
Entr
y Thr
ead
15.0mm
MetricEntry
Cable Gland Ordering ExamplesCable Gland Type/Size and Armour Type/Thread e.g. 501/453/H/M90 501/453/HX/M90
Cable Gland Ordering ExamplesCable Gland Type/Size and Armour Type/Thread e.g. ICG 653/H/M90 ICG 653/HX/M90
Cable Gland Ordering ExamplesCable Gland Type/Size and Armour Type/Thread e.g. 153/H/M90 153/HX/M90
'D
'
Entr
y Thr
ead
'E
'
InspectableCompound
Flameproof / Increased Safety andIndustrial general purpose
Oversize, G, H & J Cable Glands
501/453 ICG 653 and
ATEX153
International19
Smarter productswww.ehawke.com
CABLE GLAND SELECTION TABLE
Entry ThreadSize
Metric
SizeRef.
NPT
H J
M80M90M100
-
3"4"
Inner Sheath'A'
Min. Max.
Outer Sheath'B' Armour/
Braid
Armour/Braid
Min. Max.
G
Cable Acceptance Details
CABLE GLAND SELECTION TABLE
Entry ThreadSize
Metric
SizeRef.
NPT
H J
M80M90M100
-
3"4"
Inner Sheath'A'
Min. Max.
Outer Sheath'B'
Min. Max.
G
Cable Acceptance Details
CABLE GLAND SELECTION TABLE
Entry ThreadSize
Metric
SizeRef.
NPT
H J
M80M90
M100
-
3"4"
Inner Sheath/Cores
Outer Sheath 'B'
G
Cable Acceptance Details
'D'
'C''G'
'E'Min. Max.
Max.No.Of
Cores
Max.OverCores
Max.Inner
Sheath
'C''G'
Armour/Braid
'C''G'
# Please advise type and size of armour to enable correct clamping rings to be fitted. Assembly instruction data sheet No. A.I. 329.
Assembly instruction data sheet No. A.I. 327.
Assembly instruction data sheet No. A.I. 329.
# Please advise type and size of armour to enable correct clamping rings to be fitted.
# Please advise type and size of armour to enable correct clamping rings to be fitted.
67.067.075.0
73.077.691.6
75.075.088.0
89.589.5104.5
67.067.075.0
73.077.691.6
75.0 121121121
121121121
121121121
75.088.0
89.589.5104.5
62.870.9
80.3
74.083.0
93.0
140160180
75.075.088.0
89.589.5104.5
###
###
###
To the best of our knowledge the information contained in this brochure, is accurate at the time of going to print and the company reserves the right to improve or modify any product illustrated without notification. The company is unable to accept liability for any inaccuracies, errors or omissions that may exist. It is the customer's responsibility to ensure that the product is suitable for their application.
All copyright reserved-Hawke Cable Glands Ltd 2001.This document and all copyright therein is the property of: Hawke International a trading name of Hawke Cable GlandsLtd (A member of the McKechnie Group of Companies).Copyright Condition: This document shall be used only for the purpose for which it is provided and no reproduction or publication of the document may be made and no article may be manufactured or assembled in accordance with information contained in the document without prior written consent of the owner.
'G' Approx
'G' Approx
'G' Approx
Application
Function
Technical Data
Materials & Finishes
'G' Approx15.0mm
MetricEntry
'B
'
'A
'
Armour/Braid'C'
Entr
y Thr
ead
Outdoor or Indoor use. For use with single wire armoured 'W', wire braided 'X' and steel tape armoured 'Z' elastomer and plastic insulated cables.
ATEX Cable Gland Ordering ExamplesCable Gland Type/Size/Thread e.g. 351/RAC/C/M32 351/RAC/C/1" NPT
Increased Safety EExe. II 2 GD BASEEFA Certificate No. BAS 01 ATEX 2268X. For sizes Os - F. BASEEFA Certificate No. BAS 01 ATEX 2348X. For sizes G - J. Suitable for use in Zone 1, Zone 2, Zone 21 and Zone 22. Suitable for use in Gas Groups IIA, IIB and IIC.
IP66 ingress protection to IEC 60529 and EN 60529. Operating temperature range -60C to +80C as standard.
Provides armour clamping using one clamping arrangement for all armour/braid types 'W', 'X' and 'Z'. Deluge protection option available. Provides a high pullout resistance and low smoke and fume, zero halogen seal onto the cables outer sheath.
Hawke cable glands are manufactured as standard in brass.Alternative materials and plating are available.
Construction and test standards EN 50014, EN 50019 and 50281-1-1.IEC 60079-0 and IEC 60079-7.
See technical section of catalogue for installation rules and regulations.
Increased Safety
351/RAC Cable Gland Type
ATEX
International20
Smarter productswww.ehawke.com
CABLE GLAND SELECTION TABLE
Entry ThreadSize
Metric
SizeRef.
NPT*
'G'
AcrossFlats
AcrossCorners
HexagonDimensions
OsOABCC2DE
F
H J
M20M20
M20M25M32M40
M50M63M75
M80M90M100
""
2"
2"3"
-
3"4"
8.011.914.320.226.5
32.544.456.368.2
12.516.922.028.036.046.057.0
20.526.033.041.052.665.3
78.0
24.024.030.036.046.055.0
65.080.095.0
27.727.734.641.653.163.575.192.4109.6
Inner Sheath'A'
Max.
Outer Sheath'B'
Min. Max.
G
Cable Acceptance Details
5.5 12.09.5 16.0
98
0.9/1.250.9/1.250.9/1.251.25/1.61.6/2.01.6/2.01.8/2.51.8/2.51.8/2.5
0/0.70/0.70/0.70/0.70/0.70/0.70/1.00/1.00/1.0
81818395
105133126134
Alternative thread sizes available. See page 38Alternative non-standard armour clamping rings available. See page 38Accessories including locknuts, sealing washers, shakeproof washers, earth tags, shrouds, adaptors and reducers available. See pages 33 - 37
All Metric entry threads are 1.5mm pitch medium fit. All dimensions in millimetres (except*). Sizes Os and O are available with an M16 thread size. For O size with M16 thread, the maximum cable inner sheath diameter is 10.9mm.# Dedicated armour clamping rings are fitted. Please specify armour type and size. Assembly instruction data sheet No. A.I. 308. For sizes O to F.Assembly instruction data sheet No. A.I. 335. For sizes G to J.
Larger cable glands available in 351 design as shown below.
1"1"
""
###
###
'C'Armour/Braid
Orientation2
Orientation1
To the best of our knowledge the information contained in this brochure, is accurate at the time of going to print and the company reserves the right to improve or modify any product illustrated without notification. The company is unable to accept liability for any inaccuracies, errors or omissions that may exist. It is the customer's responsibility to ensure that the product is suitable for their application.
All copyright reserved-Hawke Cable Glands Ltd 2001.This document and all copyright therein is the property of: Hawke International a trading name of Hawke Cable GlandsLtd (A member of the McKechnie Group of Companies).Copyright Condition: This document shall be used only for the purpose for which it is provided and no reproduction or publication of the document may be made and no article may be manufactured or assembled in accordance with information contained in the document without prior written consent of the owner.
121121121
72.080.090.0
75.075.088.0
89.589.5104.5
106.4
115.0127.0
123.0
132.8146.7
Application
Function
Technical Data
Materials & Finishes
'G' Approx15.0mm
MetricEntry
'B
'
Entr
y Thr
ead
Cable Gland Ordering ExamplesCable Gland Type/Size/Thread e.g. 121/C/M32 121/C/1" NPT
IP66, IP67 and IP68 ingress protection to IEC 60529 and EN60529.DTS01 deluge protection certified by ITS.Operating temperature range -60C to +80C as standard.
Hawke cable glands are manufactured as standard in brass.Alternative materials and plating are available.
Construction and test standards EN 50262. BS 6121 Part 1. Type A2.
Outdoor or Indoor use. For use with non-armoured elastomer and plastic insulated cables.
Provides a high pullout resistance seal onto the cables outer sheath.
Industrial general purpose
121 Cable Gland Type
International21
Smarter productswww.ehawke.com
CABLE GLAND SELECTION TABLE
Entry ThreadSize
Metric
SizeRef.
NPT*
'G'
AcrossFlats
AcrossCorners
HexagonDimensions
OsOABCC2DE
F
HJ
M20M20
M20M25M32M40
M50M63M75M80
M90M100
""
2"
2"3"-
3"4"
3.07.5
11.013.019.025.0
31.542.554.5
8.011.914.320.226.532.5
44.456.368.2
8.59.515.522.027.539.048.5
13.415.421.228.034.846.558.3
24.0383938414342585356565656
24.030.036.046.055.0
65.080.095.0
27.727.734.641.653.163.575.192.4109.6
Min. Max.
Outer Sheath 'B'
Min. Max.
G
Cable Acceptance Details
- -- -
1"1"
""
StandardSeal
AlternativeSeal (S)
- -- -- -
Cable Gland with Alternative Seal (S)
e.g. 121/C/M32/S 121/C/1" NPT/S
67.067.075.0
73.077.691.6
106.4
115.0127.0
123.0
132.8146.7
Alternative entry thread types and sizes available. See page 38Accessories including locknuts, sealing washers, shakeproof washers, shrouds, adaptors and reducers available. See pages 33 - 37
All Metric entry threads are 1.5mm pitch medium fit.All dimensions in millimetres (except*). Sizes Os and O are available with an M16 thread size. For O size with M16 thread, the maximum cable outer sheath diameter is 10.9mm.Assembly instruction data sheet No. A.I. 307. For sizes Os to F.Assembly instruction data sheet No. A.I. 326. For sizes G to J.
To the best of our knowledge the information contained in this brochure, is accurate at the time of going to print and the company reserves the right to improve or modify any product illustrated without notification. The company is unable to accept liability for any inaccuracies, errors or omissions that may exist. It is the customer's responsibility to ensure that the product is suitable for their application.
All copyright reserved-Hawke Cable Glands Ltd 2001.This document and all copyright therein is the property of: Hawke International a trading name of Hawke Cable GlandsLtd (A member of the McKechnie Group of Companies).Copyright Condition: This document shall be used only for the purpose for which it is provided and no reproduction or publication of the document may be made and no article may be manufactured or assembled in accordance with information contained in the document without prior written consent of the owner.
Application
Function
Technical Data
Materials & Finishes
'G' Approx15.0mm
'B
'
Entr
y Thr
ead
MetricEntry
Cable Gland Ordering ExamplesCable Gland Type/Size/Thread e.g. 123/C/M32 123/C/1" NPT
IP66, IP67 and IP68 ingress protection to IEC 60529 and EN 60529.DTS01 deluge protection certified by ITS.Additional deluge protection seal also available.Operating temperature range -60C to +80C as standard.
Hawke cable glands are manufactured as standard in brass.Alternative materials and plating are available.
Construction and test standards EN 50262. BS 6121 Part 1. Type A2.
Outdoor or Indoor use. For use with non-armoured elastomer and plastic insulated cables. May be used on cables incorporating inner and outer cable sheaths.
Provides a high pullout resistant seal onto the cables outer sheath at two independent sealing points.
Cable Gland with Alternative Seal (S)
e.g. 123/C/M32/S 123/C/1" NPT/S
Industrial general purpose
123 Cable Gland Type
International22
Smarter productswww.ehawke.com
CABLE GLAND SELECTION TABLE
Entry ThreadSize
Metric
SizeRef.
NPT*
'G'
AcrossFlats
AcrossCorners
HexagonDimensions
OsOABCC2DE
F
HJ
M20M20
M20M25M32M40
M50M63M75M80
M90M100
""
2"
2"3"-
3"4"
3.07.5
11.013.019.025.0
31.542.554.567.067.075.0
73.077.691.6
8.011.914.320.226.532.5
44.456.368.2
8.59.515.522.027.539.048.5
13.415.421.228.034.846.558.3
24.0676864697273
10098
100100100100
24.030.036.046.055.0
65.080.095.0
27.727.734.641.653.163.575.192.4109.6
106.4
115.0127.0
123.0
132.8146.7
Min. Max.
Outer Sheath 'B'
Min. Max.
G
Cable Acceptance Details
- -- -
1"1"
""
StandardSeal
AlternativeSeal (S)
- -- -
- -
Alternative thread sizes available. See page 38 Accessories including locknuts, sealing washers, shakeproof washers, shrouds, adaptors and reducers available. See pages 33 - 37
All Metric entry threads are 1.5mm pitch medium fit.All dimensions in millimetres (except*). Sizes Os and O are available with an M16 thread size. For O size with M16 thread, the maximum cable outer sheath diameter is 10.9mm.Assembly instruction data sheet No. A.I. 306. For sizes Os to F.Assembly instruction data sheet No. A.I. 334. For sizes G to J.
To the best of our knowledge the information contained in this brochure, is accurate at the time of going to print and the company reserves the right to improve or modify any product illustrated without notification. The company is unable to accept liability for any inaccuracies, errors or omissions that may exist. It is the customer's responsibility to ensure that the product is suitable for their application.
All copyright reserved-Hawke Cable Glands Ltd 2001.This document and all copyright therein is the property of: Hawke International a trading name of Hawke Cable GlandsLtd (A member of the McKechnie Group of Companies).Copyright Condition: This document shall be used only for the purpose for which it is provided and no reproduction or publication of the document may be made and no article may be manufactured or assembled in accordance with information contained in the document without prior written consent of the owner.
Application
Function
Technical Data
Materials &