HEATING AND COOLING SOLUTIONS
DUCTED SYSTEMS
MOS
T SATISFIED CUSTOMERS
SRENOITIDNOC RI
A
20192019
MHIAA607_RAC 2018_Japan.indd 2-3 2/10/2018 5:19 pm
2 3
MITSUBISHI HEAVY INDUSTRIES AIR CONDITIONERS AUSTRALIA Mitsubishi Heavy Industries Air-Conditioners Australia (MHIAA) is one of Australia’s leading suppliers of premium residential and commercial air conditioning systems. Delivering engineering excellence for over 130 years, the Mitsubishi Heavy Industries brand is instantly recognisable for quality and technological advancement. With innovation central to both the organisation and the development of air conditioning systems, Mitsubishi Heavy Industries carries a strong philosophy of engineering products that are designed to improve the lives of those who use them and, at the same time, create a sustainable future for our company and the world we live in.
BRAND AMBASSADOR TARA DENNIS Interior designer and Television presenter Tara Dennis joins Mitsubishi Heavy Industries Air-Conditioners Australia as the brand’s first ambassador to Australia and New Zealand. With extensive experience in home decoration and design, Tara represents the home renovator looking to improve the design of their homes. “As someone who has a passion for styling and renovating you want to push the boundaries and create a space that people love being in. Mitsubishi Heavy Industries Air conditioners Australia is the perfect extension of this and a brand that I am proud to be supporting”
COMMITTED TO QUALITY Standing behind the quality of our products, is our commitment to our customers and our after sales service guarantees. Along with the rigorous quality assurance testing carried out on all Mitsubishi Heavy Industries products, comprehensive warranties provide you with peace of mind and carry our commitment to quality.
5 YEARS PARTS AND LABOUR WARRANTY Mitsubishi Heavy Industries Air conditioners Australia focuses solely on manufacturing high performance air conditioners for the Australian market. All our systems are of the highest quality and are backed by a full 5 year parts and labour warranty.
EXCEEDING ENERGY PERFORMANCE STANDARDS To comply with Australian standards and deliver the most efficient solutions possible to our customers, all Mitsubishi Heavy Industries Air conditioners Australia systems meet and exceed the Minimum Energy Performance Standards (MEPS).
MEPSCOMPLIANT
AUSTRALIA'S BEST AIR CONDITIONER BRANDWe’re proud to have been named by CHOICE® as Australia’s best brand of air conditioner for the second year in a row whilst also being named by Canstar Blue as having the most satisfied customers of any air conditioner brand in Australia. If you’re considering replacing or upgrading your air conditioner, why not choose the best?
MOS
T SATISFIED CUSTOMERS
SRENOITIDNOC RI
A20192019
4 5
MHIAA Ducted SystemsOur powerful yet quiet reverse cycle ducted systems let you enjoy the comfort of air conditioning in every part of your home or office with one packaged solution. With a discreet, low profile design that can be completely concealed in your ceiling and a variety of capacities and control options available, our ducted systems offer a flexible solution for any new or existing home.
Mitsubishi Heavy Industries ducted systems include an indoor unit (fan coil), outdoor unit (condenser) and controller while an installer will also incorporate insulated ducting, air outlets and a return air inlet with a filter. These components work in unison to offer a complete heating and cooling solution and ensure your comfort all year round.
All Mitsubishi Heavy Industries ducted systems are reverse cycle and have undergone strict and rigorous testing and quality control measures to ensure they are of the highest standards and will withstand the tough Australian climate.
IMPROVED HEAT EXCHANGER
HIGH EFFICIENCY COMPRESSOR
BLUE FIN TECHNOLOGYCOATED
PCB
WIDE OPERATION RANGEWith our advanced technology and high quality components, Mitsubishi Heavy Industries air conditioners can operate in ambient outdoor temperatures as low as -20˚C in heating mode and as high as +46˚C in cooling mode.
This permits the installation in areas where the temperature conditions can be considered extreme.
DC PAM INVERTERThe PAM control used in Mitsubishi Heavy Industries air conditioners helps minimise the loss of electricity and boost the efficiency by allowing the unit to reach the temperature quickly before slowing down the compressor. This allows the unit to save energy while maintaining a comfortable temperature in the room.
IMPROVED HEAT EXCHANGEROur new and improved heat exchanger has been developed to improve refrigerant distribution and increase the systems effectiveness. The new design features a larger heat exchange area, boosting the unit’s overall efficiency.
HIGH EFFICIENCY COMPRESSOR
One of the key features that provides Mitsubishi Heavy Industries air conditioners with their powerful performance is our highly efficient compressor. Combined with a Neodymium motor that uses powerful, rare earth magnets, Mitsubishi Heavy Industries air conditioners can deliver a higher motor efficiency while producing much less operational noise.
BLUE FIN TECHNOLOGYMitsubishi Heavy Industries outdoor units are coated with specially formulated layers that assist in preventing the hydrophilicity effect and assists in reducing the corrosion rate of the aluminium section from harsh Australian weather conditions.
COATED PCBTo protect against humid weather a protective coating is applied to the circuit board in the outdoor unit, allowing it to withstand Australia’s varying weather conditions and ensure the longevity of your system.
Our Technology
DUCTING TO DISTRIBUTEAIR THROUGHOUT YOUR HOME
SMALL REFRIGERANT PIPING
OUTLETS
OUTDOOR UNIT
INDOOR UNIT
RETURN AIRINLET WITH FILTER
6 7
REVERSE CYCLE
FDUM Series
HYPER-INVERTER TECHNOLOGYOur advanced hyper-inverter technology allows our ducted systems to reach the desired temper-ature quicker than ever before. Once the system has reached the set temperature it will ramp down and maintain this closely, switching on only when required - ensuring your comfort all year round and reducing energy consumption.
MEDIUM STATIC PRESSURESINGLE PHASE MODELS (5.0KW - 5.6KW)
IMPROVED SERVICEABILITYDesigned to improve serviceability the fan unit(comprised of impeller and motor) in the FDUM series can be easily accessed from either the side or bottom of the unit and pulled out for trou-ble-free maintenance.
FLEXIBLE INSTALLATIONWith a built-in drain pump, which includes a lift of 600mm, the FDUM allows greater flexibility during installation, making it the perfect solution for applications with limited ceiling space.
5.0kW | 5.6kW Our FDUM series of medium static ducted systems are quiet, compact and come in both 5.0kW and 5.6kW ca-pacities. Incorporating a range of convenient and energy saving features and functions, the FDUM series is the perfect multi-room heating and cooling solution for smaller Aussie homes.
Energy Saving Silent Operation Weekly/Sleep/Peak-Cut Timer
Hi Power Automatic Operation
Self-Diagnostics
Wi-Fi WIRELESS
OTHER CONTROL OPTIONS(SOLD SEPARATELY)
*See pg. 12 for full list of features and functions
QUIET OPERATIONThe FDUM series boasts a super quite operation level of 25 dB (A) on low fan speed. Combined with the unit’s Silent Mode, the FDUM is perfect for bedrooms and ensures a good night’s sleep for you and your family.
REVERSE CYCLE
FDU Series
MED/HIGH STATIC PRESSURESINGLE PHASE MODELS (7.1 KW - 14.0KW)THREE PHASE MODELS (12.5KW - 14.0KW)
7.1kW | 10.0kW | 12.5kW | 14.0kW Our NEW FDU series of slimline ducted systems are a quiet and discreet solution for multiple rooms. Coming in a range of capacities ranging from 7.1kW up to 14kW and incorporating a range of convenient features and functions, the FDU series is the perfect heating and cooling solution for any sized Aussie home.
Energy Saving Silent Operation Weekly/Sleep/Peak-Cut Timer
Hi Power Automatic Operation
Self-Diagnostics
INCREASED ENERGY EFFICIENCYWith an improved heat exchanger in the outdoor unit, boosting refrigerant distribution throughout the system, coupled with our highly efficient DC fan motor within the indoor unit, the FDU series boasts industry leading energy efficiencies which means reduced running costs for your home.
BALANCED AIRFLOWGiven every home is different, the FDU range al-lows the system’s static pressure to be set man-ually during installation. This ensures the system delivers the perfect amount of airflow to each room - no matter what the setup, ensuring year round comfort for everyone in your home.
QUIET OPERATIONThanks to our highly efficient DC fan motor, the FDU series boasts some of the quietest operation levels on the market - with our 7.1kW unit achieving a market leading low of 25 dB (A) on low fan speed. Combined with the unit’s Silent Mode, the FDU series ensures no interruptions to room acoustics and a good night’s sleep for you and your family.
*See pg. 12 for full list of features and functions
SLIM LOW PROFILE DESIGNWith a slim, low-profile design measuring only 280mm in height, the FDU series offers the perfect solution for applications where ceiling space is limited.
Wi-Fi WIRELESS
OTHER CONTROL OPTIONS(SOLD SEPARATELY)
NEW
8 9
REVERSE CYCLE
SRR Series
SUPER SLIM LOW PROFILE DESIGNWith a super slim, low-profile design measuring only 200mm in height, the SRR series offers the perfect solution for apartments or applications where ceiling space is limited and the indoor unit needs to be fitted in a concealed area.
SUPER QUIET OPERATIONThe SRR series offers some of the quietest opera-tion levels on the market achieving 24 dB(A) on low fan mode - perfect for bedrooms.
BUILT-IN DRAIN PUMPCapitalising on Mitsubishi Heavy Industries exten-sive experience in drain pump technology, the SRR series features a built-in condensation drain pump for easier installation.
ECO MODEFuzzy logic algorithms allows the unit to accurately determine the most suitable operating mode, temperature setting and automatically adjusts the inverter frequency accordingly.
Wi-Fi WIRED
2.5kW | 3.5 kWOur low profile bulkhead systems are designed to sit within your ceiling space and distribute air via discreet grilles. These compact units require no ducting and are perfect for renovated spaces and applications such as apartments where space is at a premium as they can be factored in to the finished design to provide a quiet, efficient and integrated heating and cooling solution.
Energy Saving Silent Operation Weekly/Sleep/Peak-Cut Timer
Hi Power Automatic Operation
Self-Diagnostics
*See pg. 12 for full list of features and functions
BULKHEAD SYSTEMSINGLE PHASE MODELS (2.5KW - 3.5KW)
OTHER CONTROL OPTIONS(SOLD SEPARATELY)
REVERSE CYCLE
FDUA Series
INCREASED ENERGY EFFICIENCYWith an improved heat exchanger in the outdoor unit, boosting refrigerant distribution throughout the system, coupled with our highly efficient DC fan motor within the indoor unit, the FDUA series boasts industry leading energy efficiencies which means reduced running costs for your home.
HIGH STATIC PRESSURESINGLE PHASE MODELS (7.1 KW - 14.0KW)THREE PHASE MODELS (12.5KW - 20.0KW)
BALANCED AIRFLOW Given every home is different, the FDUA range allows the system’s static pressure to be set man-ually during installation. This ensures the system delivers the perfect amount of airflow to each room - no matter what the setup, ensuring year round comfort for everyone in your home.
QUIET OPERATIONThanks to our highly efficient DC fan motor, the FDUA series boasts some of the quietest operation levels on the market - with our 7.1kW unit achieving a market leading low of 25 dB (A) on low fan speed. Combined with the unit’s Silent Mode, the FDUA series ensures no interruptions to room acoustics and a good night’s sleep for you and your family.
Wi-Fi WIRELESS
7.1kW | 10.0kW | 12.5kW | 14.0kW |16.0kW | 20.0kWOur FDUA series of ducted systems are a quiet and discreet solution for multiple rooms. Coming in a range of capacities ranging from 7.1kW up to 20kW and incorporating a range of convenient features and functions, the FDUA is the perfect heating and cooling solution for any sized Aussie home.
Energy Saving Silent Operation Weekly/Sleep/Peak-Cut Timer
Hi Power Automatic Operation
Self-Diagnostics
BUILT-IN DRAIN PUMPCapitalising on Mitsubishi Heavy Industries ex-tensive experience in drain pump technology, the FDUA series features a built-in condensation drain pump for easier installation.
*See pg. 12 for full list of features and functions
OTHER CONTROL OPTIONS(SOLD SEPARATELY)
10 11
Airzone Zoning SolutionEasily integrated into any MHIAA ducted system the advanced Airzone zoning solution offers the ultimate level of comfort by providing complete temperature control over each individual zone of your home or office.
AIRZONE ZONE CONTROLLER • Individual temperature and on/off control of up to 6 zones when used in conjunction with Airzone zoning solution*.• Control the set temperature, operation mode and fan speed.• Turn unoccupied zones off to save energy.• Control your system using your smart device (iPhone, iPad, Android) or internet browser via easy to use Airzone app.• Access timer and scheduling functions.*Blueface controller shown (AZVAFBLUEFACECB)**Airzone zoning solution includes motorised dampers, Airzone control board and webserver (sold separately)
UNOCCUPIED ZONETURNED OFF
OCCUPIED ZONETURNED ON
OCCUPIED ZONETURNED ON
FLEXIZONE®
WIRED ZONE CONTROLLER• Individual on/off control of up to 4 zones when used in conjunction with MHIAA’s zoning solution*.• Large, 3.8” backlit LCD touch screen with easy to navigate menu.• Control the operation mode and set temperature of your system.• Access timer and scheduling functions.• Access additional features including Home Leave mode, Silent Mode and High Power mode.• Multi-language display (6 languages)*RC-EXZ3A controller shown.**MHIAA zoning solution includes relay board (MH-4ZRM). Transformer sold separately.
Control OptionsWIRED CONTROLLER• Large, 3.8” backlit LCD touch screen with easy to navigate menu.• Control the set temperature, operation mode and fan speed.• Access timer and scheduling functions.• Access additional features including Home Leave mode, Silent Mode, High Power mode plus many more.• Multi-language display (6 languages)*RC-EXZ3A controller shown.**Requires SC-BIKN2-E kit (sold separately) for use with bulkhead systems. ***Function limitations may apply.
FlexiZone Zoning Solution
WIRELESS CONTROLLER• Easy to use wireless remote.• Large, LCD display.• Control the set temperature, operation mode and fan speed.• Access timer and scheduling functions.*Wireless controller from RCN-KIT4-E2 shown. Standard with bulkhead systems. **Requires RCN-KIT4-E2 wireless kit (sold separately) for use with ducted systems.***Function limitations may apply.
WI-FI• Control your system using your smart device (iPhone, iPad, Android) or internet browser via to easy to use IntesisHome app.• Control the set temperature, operation mode and fan speed.• Control your system via your Google or Amazon smart speaker device.• Control your system using Voice Command.• Set up ‘favourite’ scenes and activate them with a single tap.• Set your system to respond to the weather, you arriving home, calendar
events + more**.• Receive instant notifications and email updates and create usage logs**.
*Requires MH-RC-WIFI-1B Wi-Fi adaptor (sold separately) for use with ducted systems.*Requires MH-AC-WIFI-1 Wi-Fi adaptor (sold separately) for use with bulkhead systems.**In conjunction with IFTTT and other apps (must be downloaded separately).Some additional functions may not be available via IntesisHome app.In some applications, a 12V DC external power supply may be required for MH-RC-WI-FI-1B.
Controlling your device with IntesisHome app requires aforementioned Wi-Fi adaptors and working internet or Wi-Fi connection. Google Account required for use with Google devices. Features and services may change without notice. Google is a trademark of Google LLC.
AIRZONE ZONE CONTROLLER • Individual temperature and on/off control of up to 6 zones when used in conjunction with Airzone zoning solution*.• Control the set temperature, operation mode and fan speed.• Turn unoccupied zones off to save energy.• Control your system using your smart device (iPhone, iPad, Android) or internet browser via easy to use Airzone app.• Access timer and scheduling functions.*Blueface controller shown (AZVAFBLUEFACECB)**Airzone zoning solution includes motorised dampers, Airzone control board and webserver (sold separately)
Siri
12 13
FUNCTION DESCRIPTION FDU FDUA FDUM SRR
AIR
FLO
W
Automatic Fan Speed
On-board microcomputer continuously monitors the room’s air temperature and adjusts the air flow automatically.
Air FilterThe air filter in the unit traps and removes airborne dust particles and other allergens to provide you with a clean air function.
Filter Sign Alerts you to when the filter needs to be cleaned.
Outside Air Intake
Provides clean fresh air into the room through the external air intake, avoiding the constant recycling of internal air.
Self-Clean Operation
Dries the indoor unit components by running the fan on ultra-low mode, preventing the growth of mould. Designed to be run regularly after use.
ENER
GY
SAVI
NG
Set Temperature Auto Return*
Allows you to program a preferred set temperature that the unit will return to each time it is operated.
Home Leave Operation*
Will maintain a moderate indoor temperature, avoiding extremely hot or cool temperatures. Perfect for when you’re away on holidays.
Eco Operation
The unit operates at a slightly reduced capacity to reduce power consump-tion while maintaining a comfortable room temperature.
CO
MFO
RT&
CO
NVE
NIE
NC
E
Hi Power Operation*
Provides 15mins of boosted power allowing you to quickly heat or cool your home before returning to normal operation. Perfect for when you first turn on the unit.
Dry OperationReduces humidity by removing moisture from the air without effecting the indoor temperature.
Silent OperationAllows you to program periods where the unit will operate with reduced noise levels, perfect for night time and an uninterrupted sleep.
Automatic Operation
Automatically selects the required heating or cooling function based on the current room conditions.
Function Switch*From the six available functions on the unit, this function allows you to set two functions to operate automatically. (Note: this is not available when a centralised remote control is connected).
TIM
ERS
On/Off TimerSet your unit to turn on and off once, at specific times, within a 24 hour period. Unit will then turn on and off at the specified times every day.
Weekly TimerSet your unit to turn on and off automatically on a weekly basis to suit your usual room usage on each day.
Sleep TimerThis function allows you to set a per-determined amount of time between 30 and 240 mins that your unit will operate for before switching off.
10 C
Night SetbackDesigned for the colder seasons, this function ensures the room tempera-ture is kept at around 10˚C, even while unoccupied.
Peak-Cut Timer*This function lets you to preset the capacity limit during certain periods of the day, minimising energy consumption during peak billing times, thus reducing operation costs.
MA
INTE
NA
NC
E &
PR
EVEN
TIO
N
Child LockLocks the remote control to prevent little ones from changing functions and other settings. Useful for families with curious young children.
Self-DiagnosticsMicrocomputer automatically runs a diagnostic of the system in the event of a malfunction. This enables your authorised dealer to isolate and repair any issues.
Improved Serviceability
The fan unit (comprised of impeller and motor) is easily accessible from either the side or bottom of the unit and can be slid out for easy maintenance.
Built-in Drain Pump
The built-in drain pump, which includes a lift of 600mm, allows greater flexibility with installation, offering a great solution for applications with limited space.
Auto Restart Function
Automatically restarts the unit in the same operating mode if it suffers a loss of power.
Features and Functions
*Functions can only be enabled using RC-EXZ3A wired controller.
FDU
M &
FD
U S
ER
IES
PR
OD
UC
T S
PE
CIF
ICA
TIO
NS
FDU
M50
-60V
HFD
CA
100V
N, F
DC
100V
NP
SR
C50
-60Z
MXA
-S
FDC
A12
5-14
0VS
XFD
CA
71VN
X FD
U71
-140
VH
* O
pera
tion
data
has
bee
n ga
ther
ed in
acc
orda
nce
with
AS
/NZS
382
3 st
anda
rds.
For
test
ing
cond
ition
s pl
ease
refe
r to
Pag
e 15
CA
PA
CIT
Y5.
0 K
W5.
6 K
W7.
1 K
W10
.0K
W10
.0 K
W12
.5 K
W14
.0 K
W12
.5 K
W14
.0 K
W
Set
FDU
M50
ZM
XA
VH
FDU
M60
FDU
71A
VN
XA
VH
FDU
100V
NP
1VH
FDU
100A
VN
VF2
FDU
125A
VN
XVH
FDU
140A
VN
XVH
FDU
125V
SXV
HFD
U14
0AV
SXV
H
Indo
orFD
UM
50V
HFD
UM
60V
HFD
U71
VH
FDU
100V
HFD
U10
0VH
FDU
125V
HFD
U14
0VH
FDU
125V
HFD
U14
0VH
Out
door
SR
C50
ZMXA
-SS
RC
60ZM
XA-S
FDC
A71
VN
XAFD
C10
0VN
PFD
CA
100V
NFD
CA
125V
NX
FDC
A14
0VN
XFD
C12
5VS
XFD
CA
140V
SX
Pow
er S
ourc
e (O
utdo
or U
nit)
1 P
hase
240
V 5
0Hz
3 P
hase
380
-415
V 5
0Hz
*Ope
ratio
n D
ata
Nom
inal
Cap
acity
R
ange
Coo
ling
T1
kW
5.0
(2.2
-5.6
)5.
6 (2
.8-6
.3)
7.1
(3.2
-8.0
)10
.0 (2
.8-1
1.2)
10.0
(4.0
-11.
2)12
.5 (5
.0-1
4.0)
14.0
(5.0
-16.
0)12
.5 (5
.0-1
4.0)
14.0
(5.0
-16.
0)
Hea
ting
H1
5.4
(0.6
-6.3
)6.
7 (0
.6-7
.1)
8.0
(3.6
-9.0
)11
.2 (2
.5-1
2.5)
11.2
(4.0
-12.
5)14
.0 (4
.0-1
7.0)
16.0
(4.0
-18.
0)14
.0 (4
.0-1
8.0)
16.0
(4.0
-20.
0)
Hea
ting
H2
4.3
4.9
7.0
8.27
11.4
13.7
14.3
16.2
NA
Pow
er C
onsu
mpt
ion
Coo
ling
T1kW
1.56
1.75
2.20
3.00
2.92
3.60
4.40
3.60
4.40
Hea
ting
H1
1.70
2.00
2.20
2.93
3.20
3.90
4.54
3.90
4.54
Max
Pow
er C
onsu
mpt
ion
kW2.
902.
903.
544.
604.
236.
306.
197.
807.
74
Run
ning
Cur
rent
Coo
ling
T1A
7.00
7.80
9.80
13.2
013
.10
16.0
019
.50
6.10
6.70
Hea
ting
H1
7.60
9.00
9.80
12.9
014
.30
17.4
020
.30
6.60
7.00
Inru
sh C
urre
nt, M
axim
um C
urre
ntA
5, 1
55,
15
5, 1
75,
22
5, 2
55,
29
5, 3
05,
18
5, 1
9
EE
RC
oolin
g T1
3.21
3.20
3.23
3.33
3.42
3.47
3.18
3.47
3.18
CO
PH
eatin
g H
13.
183.
353.
643.
823.
503.
593.
523.
593.
52
Sou
nd P
ower
Lev
el
(JS
C96
12)
Out
door
6364
6670
7070
7270
70
Sou
nd P
ress
ure
Leve
l (J
S C
9612
)
Indo
ordB
(A)
P-H
i:37
Hi:3
2 M
e:29
Lo:
26P
-Hi:3
6 H
i:31
Me:
28 L
o:25
P-H
i:38
Hi:3
3 M
e:29
Lo:
25P
-Hi:4
4 H
i:38
Me:
36 L
o:30
P-H
i:44
Hi:3
8 M
e:36
Lo:
30P
-Hi:4
5 H
i:40
Me:
34 L
o:29
P-H
i:47
Hi:4
0 M
e:35
Lo:
30P
-Hi:
47 H
i: 40
M
e: 3
5 Lo
: 30
P-H
i:47
Hi:4
0 M
e:35
Lo:
30
Out
door
5054
5157
4950
4948
49
Ext
erna
l Dim
ensi
ons
(HXW
XD)
Indo
orm
m28
0x75
0x63
528
0x95
0x63
528
0x95
0x63
528
0x13
70x7
4028
0×13
70×
740
280×
1370
×74
028
0×13
70×
740
280×
1370
×74
028
0×13
70×
740
Out
door
640x
800(
+71
)x29
064
0x80
0(+
71)x
290
750x
880(
+88
)x34
084
5x97
0x37
084
5x97
0x37
013
00x9
70x3
7013
00x9
70x3
7013
00x9
70x3
7013
00x9
70x3
70
Net
Wei
ght
Indo
orK
g29
3434
5454
5454
5454
Out
door
4545
6170
8210
610
610
610
6
Sup
ply
Air
Con
nect
ion
mm
170x
680
170x
880
170x
880
170x
1200
170x
1200
170x
1200
170x
1200
170x
1200
170x
1200
Ret
urn
Air
Con
nect
ion
mm
200x
660
200x
860
200x
860
235x
1280
235x
1280
235x
1280
235x
1280
235x
1280
235x
1280
Ext
erna
l Sta
tic P
ress
ure
(Max
)P
a10
010
020
020
020
020
020
020
020
0
Airfl
owIn
door
(Coo
ling)
L/s
P-H
i: 21
7 H
i: 16
7 M
e: 1
50 L
o: 1
33P
-Hi:3
33 H
i:250
M
e:21
7 Lo
:167
P-H
i: 40
0 H
i: 31
6 M
e: 2
50 L
o: 1
66P
-Hi:6
00 H
i:467
M
e:41
7 Lo
:317
P-H
i: 60
0 H
i: 46
7 M
e: 4
17 L
o: 3
17P
-Hi:6
50 H
i:533
M
e:43
3 Lo
:333
P-H
i:800
Hi:5
83
Me:
467
Lo:3
67P
-Hi:6
50 H
i:533
M
e:43
3 Lo
:333
P-H
i:800
Hi:5
83
Me:
467
Lo:3
67In
door
(Hea
ting)
Ref
riger
ant (
Type
, Am
ount
, P
re-c
harg
e Le
ngth
)
Qua
ntity
Kg
(R41
0A) 1
.5(R
410A
) 1.5
(R41
0A) 2
.95
(R41
0A) 2
.55
(R41
0A) 3
.8(R
410A
) 4.5
(R41
0A) 4
.5(R
410A
) 4.5
(R41
0A) 4
.5
Pre
Cha
rged
To
Pip
e Le
ngth
m15
1530
1530
3030
3030
Inst
alla
tion
Dat
a
Ref
riger
ant P
ipin
gLi
quid
Lin
em
mØ
6.35
Ø6.
35Ø
9.52
Ø9.
52Ø
9.52
Ø9.
52Ø
9.52
Ø9.
52Ø
9.52
Gas
Lin
eØ
12.7
Ø12
.7Ø
15.8
8Ø
15.8
8Ø
15.8
8Ø
15.8
8Ø
15.8
8Ø
15.8
8Ø
15.8
8
Con
nect
ion
Met
hod
Flar
e C
onne
ctio
n
Max
imum
Pip
e Le
ngth
(One
Way
)m
m30
3050
3050
100
100
100
100
Max
ver
tical
hei
ght d
iff. b
etw
een
O.U
. and
I.U
.20
( O
.U. a
bove
I.U
. ) /
20
( O.U
. bel
ow I.
U. )
30 (
O.U
. abo
ve I.
U. )
/
15 (
O.U
. bel
ow I.
U. )
20 (
O.U
. abo
ve I.
U. )
/
15 (
O.U
. bel
ow I.
U. )
30 (
O.U
. abo
ve I.
U. )
/ 1
5 ( O
.U. b
elow
I.U
. )
Con
trol
ler
RC
-E5,
RC
-EXZ
3A, R
CH
-E3
or
RC
N-K
IT4-
E2
Mot
ion
Sen
sor
(Opt
iona
l)LB
-KIT
Dem
and
resp
onse
(AS
4755
)Ye
sYe
sYe
sN
oYe
sYe
sYe
sN
oYe
s
15
SR
R S
ER
IES
PR
OD
UC
T S
PE
CIF
ICA
TIO
NS
SR
R25
-35Z
S-W
FDU
A S
ER
IES
FDU
A71
VF/G
FDU
A10
0-16
0VF/
GFD
CA
125-
140V
NX,
FD
CA
125-
140V
SX
FDC
A71
VNXA
PR
OD
UC
T S
PE
CIF
ICA
TIO
NS
FDU
A20
0VG
FDC
A16
0-20
0VS
AFD
CA
100V
N, F
DC
100V
NP
SRC25
-35Z
SA-W
*(1)
The
dat
a is
mea
sure
d at
the
follo
win
g co
nditi
ons:
Indo
or A
ir Te
mpe
ratu
reO
utdo
or A
ir Te
mpe
ratu
reS
tand
ards
DB
WB
DB
WB
Coo
ling
27o C
19o C
35o C
24o C
AS
/NZ
3823
.2H
eatin
g20
o C-
7o C6o C
Ope
ratio
nIte
m
CA
PAC
ITY
2.5k
W3.
5kW
Indo
orS
RR
25ZS
-WS
RR
35ZS
-W
Out
door
SR
C25
ZSA
-WS
RC
35ZS
A-W
Pow
er S
ourc
e (O
utdo
or U
nit)
1 P
hase
240
V 5
0Hz
*Ope
ratio
n D
ata
Nom
inal
Cap
acity
(Ran
ge)
Coo
ling
T1
kW
2.5
(0.9
~3.
4)3.
5 (0
.9~
4.1)
Hea
ting
H1
3.4
(0.9
~4.
8)4.
2 (1
.0~
5.2)
Hea
ting
H2
3.55
4.1
Pow
er C
onsu
mpt
ion
Coo
ling
T1kW
0.56
(0.2
0~0.
90)
0.93
(0.1
9~1.
26)
Hea
ting
H1
0.75
(0.2
0~1.
42)
1.01
(0.2
0~1.
45)
Max
imum
Pow
er C
onsu
mpt
ion
kW1.
651.
65
Run
ning
Cur
rent
Coo
ling
T1A
2.7
4.2
Hea
ting
H1
3.5
4.5
Inru
sh C
urre
nt, M
axim
um C
urre
ntA
3.5,
9.0
4.5,
9.0
EE
RC
oolin
g T1
4.46
4.16
CO
PH
eatin
g H
14.
533.
04
Sou
nd P
ower
Lev
el (J
IS C
9612
)O
utdo
ordB
(A)
6062
Sou
nd P
ress
ure
Leve
l (JI
S C
9612
) In
door
dB(A
)37
-33-
30-2
438
-34-
31-2
5
Out
door
4750
Ext
erna
l dim
ensi
ons
(HXW
XD)
Indo
orm
m20
0x75
0(+
120)
x500
200x
750(
+12
0)x5
00
Out
door
540x
780(
+62
)x29
054
0x78
0(+
62)x
290
Ene
rgy
Labe
l (G
EM
S 2
019)
Hot
Coo
ling
Sta
rs
(3.5
) (3
.5)
Hea
ting
(3.5
) (3
)
Ave
rage
Coo
ling
(3)
(3)
Hea
ting
(3)
(2.5
)
Col
dC
oolin
g (3
) (3
)
Hea
ting
(2.5
) (2
.5)
Net
wei
ght
Indo
orkg
20.5
20.5
Out
door
34.5
34.5
Airfl
owC
oolin
g (In
door
)L/
sP
-Hi:1
58 H
i:133
Me:
108
Lo:7
5P
-Hi:1
67 H
i:142
Me:
117
Lo:8
3
Hea
ting
(Indo
or)
P-H
i:167
Hi:1
50 M
e:13
3 Lo
:100
P-H
i:175
Hi:1
58 M
e:14
2 Lo
:108
Inst
alla
tion
Dat
a
Ref
riger
ant (
Type
, Am
ount
, Pre
-cha
rge
Leng
th)
Qua
ntity
kg(R
32) 0
.78
(R32
) 0.7
8
Pre
-Cha
rged
to P
ipe
m15
15
Ref
riger
ant P
ipin
gLi
quid
line
mm
Ø6.
35Ø
6.35
Gas
line
Ø9.
52Ø
9.52
Con
nect
ion
Met
hod
Flar
e co
nnec
tion
Max
imum
Pip
e Le
ngth
(One
Way
)m
20
Max
Ver
tical
Hei
ght D
iff. B
etw
een
O.U
. and
I.U
.m
10 (
O.U
. abo
ve I.
U. )
/ 1
0 ( O
.U. b
elow
I.U
. )
Sta
ndar
d ac
cess
orie
sP
olyp
ropy
lene
net
x1
Opt
iona
l par
tsIn
terfa
ce k
it (S
C-B
IKN
2-E
) / W
i-Fi K
it
Dem
and
Res
pons
e (A
S47
55)
Yes
* O
pera
tion
data
has
bee
n ga
ther
ed in
acc
orda
nce
with
AS
/NZS
382
3 st
anda
rds.
For
test
ing
cond
ition
s pl
ease
refe
r to
Pag
e 15
. **
Max
imum
70m
(Gas
pip
ing:
Ø25
.4 o
r Ø
28.5
8), M
axim
um 3
5m (G
as p
ipin
g:Ø
22.2
2)
CA
PA
CIT
Y7.
1 K
W10
.0 K
W10
.0K
W12
.5K
W14
.0K
W12
.5K
W14
.0K
W16
.0K
W20
.0K
W
Set
FDU
A71
AVN
XVF
FDU
A10
0VN
P1V
F2FD
UA
100A
VN
VF2
FDU
A12
5AV
NXV
FFD
UA
140A
VN
XVF
FDU
A12
5VS
XVF
FDU
A14
0AV
SXV
FFD
UA
160A
VS
AVF
FDU
A20
0AV
SAV
G
Indo
orFD
UA
71V
FFD
UA
100V
F2FD
UA
100V
F2FD
UA
125V
FFD
UA
140V
FFD
UA
125V
FFD
UA
140V
FFD
UA
160V
FFD
UA
200V
G
Out
door
FDC
A71
VN
XAFD
C10
0VN
PFD
CA
100V
NFD
CA
125V
NX
FDC
A14
0VN
XFD
C12
5VS
XFD
CA
140V
SX
FDC
A16
0VS
AFD
CA
200V
SA
Pow
er S
ourc
e (O
utdo
or U
nit)
1 P
hase
240
V 5
0Hz
3 P
hase
380
-415
V 5
0Hz
*Ope
ratio
n D
ata
Nom
inal
Cap
acity
R
ange
Coo
ling
T1
kW
7.1
(3.2
-8.0
)10
.0 (2
.8-1
1.2)
10.0
(4.0
-11.
2)12
.5 (5
.0-1
4.0)
14.0
(5.0
-16.
0)12
.5 (5
.0 -
14.
0)14
.0 (5
.0-1
6.0)
16.0
(6.9
-20.
0)20
.0 (6
.9-2
8.0)
Hea
ting
H1
8.0
(3.6
-9.0
)11
.2 (2
.5-1
2.5)
11.2
(4.0
-12.
5)14
.0 (4
.0-1
7.0)
16.0
(4.0
-18.
0)14
.0 (4
.0-
18.0
)16
.0 (4
.0-1
8.0)
18.0
(5.5
-22.
4)22
.4(5
.5-3
1.5)
Hea
ting
H2
7.0
8.04
10.0
14.0
15.0
16.0
14.0
15.0
22.0
Pow
er C
onsu
mpt
ion
Coo
ling
T1kW
2.20
2.99
3.05
3.83
4.44
3.83
4.44
4.83
6.03
Hea
ting
H1
2.20
2.88
2.87
3.68
4.41
3.68
4.44
4.66
5.50
Max
Pow
er C
onsu
mpt
ion
kW3.
544.
604.
026.
135.
777.
667.
2612
.70
13.7
0
Run
ning
Cur
rent
Coo
ling
T1A
9.80
13.2
013
.60
17.0
019
.70
6.40
6.80
7.80
9.50
Hea
ting
H1
9.80
12.9
012
.70
16.3
019
.60
6.20
6.70
7.60
8.70
Inru
sh C
urre
nt, M
axim
um C
urre
ntA
5, 1
75,
22
5, 2
55,
29
5, 3
05,
18
5, 1
95,
24
5, 2
7
EE
RC
oolin
g T1
3.23
3.34
3.28
3.26
3.15
3.26
3.15
3.31
3.32
CO
PH
eatin
g H
13.
643.
893.
903.
803.
633.
83.
63.
864.
07
Sou
nd P
ower
Le
vel
(JS
C96
12)
Out
door
dB(A
)
6670
7070
7270
7073
73
Sou
nd P
ress
ure
Leve
l (JS
C96
12)
Indo
orP
-Hi:3
8 H
i:33
Me:
29
Lo:2
5P
-Hi:4
3 H
i:42
Me:
40 L
o:37
P-H
i:43
Hi:4
2 M
e:40
Lo:
37P
-Hi:4
5 H
i:43
Me:
41 L
o:37
P-H
i:47
Hi:4
6 M
e:43
Lo:
40P
-Hi :
47
Hi :
46
Me
: 43
Lo :
40P
-Hi:4
7 H
i:46
Me:
43 L
o:40
P-H
i:49
Hi:4
8 M
e:45
Lo:
42P
-Hi:5
2 H
i:50
Me:
47 L
o:45
Out
door
5157
4948
4948
4959
59
Ext
erna
l Dim
ensi
ons
(HXW
XD)
Indo
orm
m28
0x95
0x63
539
8x11
50x6
5039
8x11
50x6
5039
8x11
50x6
5039
8x11
50x6
5039
8x11
50x6
5039
8x11
50x6
5039
8x11
50x6
5037
9x16
00x8
93
Out
door
750x
880(
+88
)x34
084
5x97
0x37
084
5x97
0x37
013
00x9
70x3
7013
00x9
70x3
7013
00x9
70x3
7013
00x9
70x3
7015
05x9
70x3
7015
05x9
70x3
70
Net
Wei
ght
Indo
orK
g34
5252
5252
5252
5289
Out
door
6170
8110
610
610
610
614
314
3
Sup
ply
Air
Con
nect
ion
mm
170x
880
348x
898
348x
898
348x
898
348x
898
348x
898
348x
898
348x
898
250x
1450
Ret
urn
Air
Con
nect
ion
mm
200x
860
348x
898
348x
898
348x
898
348x
898
348x
898
348x
898
348x
898
250x
1450
Ext
erna
l Sta
tic P
ress
ure
(Max
)P
a20
020
020
020
020
020
020
020
020
0
Airfl
owIn
door
(Coo
ling)
L/s
P-H
i: 40
0 H
i: 31
6 M
e: 2
50 L
o: 1
66P
-Hi:6
50 H
i:600
M
e:55
0 Lo
:483
P-H
i:650
Hi:6
00 M
e:55
0 Lo
:483
P-H
i:717
Hi:6
50
Me:
600
Lo:5
00P
-Hi:8
50 H
i:800
M
e:70
0 Lo
:600
P-H
i:717
Hi:6
50
Me:
600
Lo:5
00P
-Hi:8
50 H
i:800
M
e:70
0 Lo
:600
P-H
i:850
Hi:8
00M
e:70
0 Lo
:600
P-H
i:133
3 H
i:120
0 M
e:10
67 L
o:93
3In
door
(Hea
ting)
Ref
riger
ant (
Type
, Am
ount
, P
re-c
harg
e Le
ngth
)
Qua
ntity
Kg
(R41
0A) 2
.95
(R41
0A) 2
.55
(R41
0A) 3
.8(R
410A
) 4.5
(R41
0A) 4
.5(R
410A
) 4.5
(R41
0A) 4
.5(R
410A
) 7.2
(R41
0A) 7
.2
Pre
Cha
rged
To
Pip
e Le
ngth
m30
1530
3030
3030
3030
Inst
alla
tion
Dat
a
Ref
riger
ant P
ipin
gLi
quid
Lin
em
mØ
9.52
Ø9.
52Ø
9.52
Ø9.
52Ø
9.52
Ø9.
52Ø
9.52
Ø12
.7Ø
12.7
Gas
Lin
eØ
15.8
8Ø
15.8
8Ø
15.8
8Ø
15.8
8Ø
15.8
8Ø
15.8
8Ø
15.8
8Ø
22.2
2 , Ø
25.4
or
Ø28
.58
Ø22
.22
, Ø25
.4 o
r Ø
28.5
8
Con
nect
ion
Met
hod
Flar
e co
nnec
tion
Liqu
id: F
lare
/ G
as: B
razi
ng
Max
imum
Pip
e Le
ngth
(One
Way
)m
m50
3050
100
100
100
100
**70
**70
Max
ver
tical
hei
ght d
iff. b
etw
een
O.U
. and
I.U
.30
( O
.U. a
bove
I.U
. ) /
15
( O
.U. b
elow
I.U
. )20
( O
.U. a
bove
I.U
. ) /
15
( O
.U. b
elow
I.U
. )30
( O
.U. a
bove
I.U
. ) /
15
( O.U
. bel
ow I.
U. )
Con
trol
ler
RC
-E5,
RC
-EXZ
3A, R
CH
-E3
or
RC
N-K
IT4-
E2
Saf
ety
Pan
(Opt
iona
l)U
A-S
P1-
EU
A-S
P1-
E
UA
-SP
2-E
U
A-S
P2-
EU
A-S
P2-
EU
A-S
P2-
EU
A-S
P2-
EU
A-S
P2-
EN
/A
Mot
ion
Sen
sor
(Opt
iona
l)LB
-KIT
Dem
and
resp
onse
(AS
4755
)Ye
sN
oYe
sYe
sYe
sN
oYe
sYe
sYe
s
(2) T
he a
ir co
nditi
oner
is m
anuf
actu
red
and
test
ed in
con
form
ity w
ith th
e A
S/N
ZS.
(3) S
ound
leve
l ind
icat
es th
e va
lue
in a
n an
echo
ic c
ham
ber.
Dur
ing
oper
atio
n th
ese
valu
es a
re s
omew
hat h
ighe
r du
e to
am
bien
t con
ditio
ns.
(4) S
elec
t the
bre
aker
siz
e ac
cord
ing
to a
pplic
able
nat
iona
l sta
ndar
d.(5
) The
ope
ratio
n da
ta in
dica
te w
hen
the
air-
cond
ition
er is
ope
rate
d at
240
V 5
0Hz
for
1 ph
ase
and
400V
50H
z fo
r 3
phas
e
16 17
FDUM Series FDUM SeriesModel FDUM60VH
295~325
View M
tapping screwsHoles for
Return air duct
Drain hose piece(Accessory )
(Installed on site )
tapping screwHoles for
A Gas piping
Model
B Liquid piping
C1 Drain piping
D Hole for wiringE Suspension bolts (M10)
FOutside air opening
Air outlet openingG
Symbol Content
φ6.35 (1/4")(Flare )
for ducting
for ducting
Drain pipingC2
(Gravity drainage )
(φ150)(Knock out )
(φ125)(Knock out )
φ12.7 (1/2")(Flare )
60 71
φ9.52 (3/8")(Flare )
φ15.88 (5/8")(Flare )
H Inspection opening (450×450)
Hole
φ170
φ124
φ170
tapping screwsHoles for 4-φ4
(Suspension bolts pitch )
Control box
600
(M
ax. d
rain
lift)
or le
ss
(Duct dimension )
(Du
ct d
imen
sion)
(Su
spen
sion
bolts
pitc
h)
2847
213
5
18 950 18986
suspension boltHanger plate for
55 880 55
76 250 17
510
5
467
413471
51063530 30
280
67
86284
152 262
41200
39
65 860 65
139
□90
46 4×200=800 46
3117
031
14-φ4
58
113
Air supply duct
4317
0(
Duct
dim
ensio
n)
(Duct dimension )
69
4-φ4
200
1550M
C 2
D
A
C 1
B
G
F
F G
E
Space for installation and service
or m
ore
or m
ore
or m
ore
or m
ore
(Case 1 ) From side of unitSelect either of two cases to keep space for installation and services.
or m
ore
or m
ore
(Case 2 ) From bottom of unit
Notes (a) There must not be obstacle to draw out fan unit. For fan unit maintenance, refer to page 106. (b) Install refrigerant pipes, drain pipe,and wiring so as not to cross marked area. (c) The case that pipes are installed to upper (bottom ) of fan unit, keep space of 60mm or more to upper (bottom) of unit.
100015
0 - 200
100-200
100
Slab
2020
Note (a)
370Ceiling
Note (b)
600
1300
100
Inspectionopening
620
H
Note (c)
Fan unit
Note (a)
Note(1) The model name label is attached on the lid of the control box.
VP25 ( O.D.32 )
VP20
12-φ4
4-φ44-φ4
Notes (a) There must not be obstacle to draw out fan unit. For fan unit maintenance, refer to page 106. (b) Install refrigerant pipes, drain pipe,and wiring so as not to cross marked area. (c) The case that pipes are installed to upper (bottom) of fan unit, keep space of 60mm or more to upper (bottom) of unit.
295~325
Note (c)
Fan unit
View M
tapping screwsHoles for
Return air duct
Drain hose piece(Accessory )
(Installed on site )
Hole
tapping screwHoles for
A Gas pipingB Liquid piping
C1 Drain piping VP25 (O.D.32 )
D Hole for wiringE Suspension bolts (M10)
FOutside air opening
Air outlet openingG
Symbol Content
φ12.7 (1/2")(Flare )
for ducting
for ducting
(φ150)(Knock out )
(φ125)(Knock out )
Drain pipingC2
(Gravity drainage )VP20
φ6.35 (1/4")(Flare )
H Inspection opening (450×450)
φ170
φ124
φ170
tapping screwsHoles for
Space for installation and service
or m
ore
or m
ore
or m
ore
or m
ore
(Case 1 ) From side of unit
or m
ore
or m
ore
(Case 2 ) From bottom of unit
(Suspension bolts pitch )
Air supply duct
Control box
600
(M
ax. d
rain
lift)
or le
ss
(Duct dimension )
(Du
ct d
imen
sion)
4317
028
472
135
18 750 18786
suspension boltHanger plate for
55 680 55
76
6758
86284
152 262
41200
39
65 660 65
139
□90
46 200200 4620031
170
31
280
467
413471
510635 3030
105
175
250
(Duct dimension )
(Du
ct d
imen
sion)
69 113
100015
0-20
0
100-200
100
Slab
2020
Note (a)
370Ceiling
Note (b)
600
1100
100
Inspectionopening
620
Note (a)
Unit:mm
1550
(Su
spen
sion
bolts
pitc
h)
F G
M
E
C 2
D
A
1C
B
G
F
H
Note(1) The model name label is attached on the lid of the control box.
Select either of two cases to keep space for installation and services.
Model FDUM50VH
18 19
Models FDU100VH, 125VH, 140VH
(Duct dimension)
(Du
ct dim
ensio
n)Note(c)
Fan unit
View M
tapping screwsHoles for
Return air duct
Hole
A Gas pipingB Liquid piping
D Hole for wiringE Suspension bolts
FOutside air opening
Air outlet openingG
Symbol Content
for ducting
for ducting
Drain pipingC2 (Gravity drainage)
Drain hose piece(Accessory)
(Installed on site)
H Inspection opening
φ170
φ124
φ170
tapping screwsHoles for
Space for installation and service
or m
ore
or m
ore
or m
ore
or m
ore
(Case 1) From side of unitSelect either of two cases to keep space for installation and services.
or m
ore
or m
ore
(Case 2) From bottom of unit
Notes(a)There must not be obstacle to draw out 2 fan units. For fan units maintenance, refer to page 100. ( b)Install refrigerant pipes, drain pipe, and wiring so as not to cross marked area. ( c)The case that pipes are installed to upper(bottom)of fan unit, keep space of 60mm or more to upper(bottom)of unit.
C1 Drain piping
(M10)
φ9.52(3/8")(Flare)φ15.88(5/8")(Flare)
(Knock out)
(Knock out)
(450×450)
VP25(O.D.32)
VP20
Unit:mm
4-φ 4
(Suspension bolts pitch)
Air supply duct
Control box
(Duct dimension)
(Du
ct dim
ensio
n)
18 1368 181404
suspension boltHanger plate for
104 1200 104
92 250
184.
513
4.5
467
405468
63573830 30
280
71
59
86284
152 285
23.5
235
21.5
64 1280 64
139
� 90
600
(M
ax. d
rain
lift)
(Su
spen
sion b
olts p
itch)
2853
018
0
or le
ss
113
69
295� 325
4317
0
4-φ 4
100015
0� 200
100� 200
100
Slab
2020
Note(a)370
Ceiling
Note(b)
600
1720
100
Inspectionopening
725
Note(a)
1550
F G
M
C2
D
AC1
BG
F
E
H
Note(1)The model name label is attached on the lid of the control box.
(ii) FDU
Model FDU71VH
Unit:mm
(Suspension bolts pitch)
C2
D
(Duct dimension)
(Du
ct dim
ensio
n)
(Su
spen
sion
bolts
pitc
h)
AB
suspension boltHanger plate for
A Gas pipingB Liquid piping
D Hole for wiringE Suspension bolts
Symbol Content
Drain pipingC2 (Gravity drainage)
Space for installation and service
H Inspection opening
Note(a)
or m
ore
or m
ore
Air supply duct
E
(Du
ct dim
ensio
n)
(Duct dimension)
(Case 1) From side of unitSelect either of two cases to keep space for installation and services.
or m
ore
or m
oreInspection
opening
(Case 2) From bottom of unit
Slab
or m
ore
or m
ore
Ceiling
Note(b)
Note(a)
Notes(a)There must not be obstacle to draw out fan unit. For fan unit maintenance, refer to page 71. ( b) Install refrigerant pipes, drain pipe, and wiring so as not to cross marked area. ( c) The case that pipes are installed to upper(bottom)of fan unit, keep space of 60mm or more to upper(bottom)of unit.
Note(c)
Fan unit
View M
tapping screwsHoles for
Hole
φ 170
φ 124
φ 170
tapping screwsHoles for
C1 Drain piping
FOutside air opening
Air outlet openingG
for ducting
for ductingReturn air duct Drain hose piece(Accessory)(Installed on site)
(M10)
φ 9.52(3/8")(Flare)φ 15.88(5/8")(Flare)
(450×450)
VP25(O.D.32)
(Knock out)
(Knock out)
VP20
2847
213
5
18 950 18986
55 880 55
250 175
105
467
471510
63530 30
280
67
86
41200
39
65 740 185
100015
0- 200
100- 200
100
58
4317
0
600
1300
100
620
2020
370
15
413
4-φ 4152 262
139
� 90
113
4-φ 4
284
6960
0(
Max
. dra
in lift)
or le
ss
76
295- 325
Control box
50
F G
M
C1
H
G
F
Note(1)The model name label is attached on the lid of the control box.
FDU SeriesFDU Series
20 21
SRR SeriesFDUA SeriesModels FDUA100VH, 125VH, 140H
Unit:mm
A Gas pipingB Liquid piping
D Hole for wiringE Suspension bolts (M10)
Symbol Content
Drain pipingC2
φ9.52(3/8")(Flare)φ15.88(5/8")(Flare)
F Inspection hole (450×450)
(Suspension bolts pitch)
Control box
C2
D
(Duct dimension)
(Du
ct dim
ensio
n)(
Susp
ensio
n bo
lts p
itch)
AB
suspension boltHanger plate for
Air supply duct
E
(Du
ct dim
ensio
n)
(Duct dimension)
(Gravity drainage)
Unde
r
C1 Drain piping VP25(I.D.25,O.D.32)
VP25(I.D.25,O.D.32)
Return air duct Drain hose piece(Accessory)(Installed on site)
2847
215
0
17.5 1150 17.51185
111 898 181
370 24
8 172
506
498531
65040 40
398
74
86
2634
824
111 898 181
61
2434
8
1560
458
600
(M
ax. d
rain
lift)
or le
ss
215
295- 325
284
69 C1
Space for installation and service
(Case 1) From side of unitSelect either of two cases to keep space for installation and services.
Inspectionhole
(Case 2) From bottom of unit
Note(a)
out fan unit. For fan unit maintenance,
(b) Install refrigerant pipes,
not to cross marked area.
Notes(a) There must not be obstacle to draw
drain pipe,and wiring so as
refer to page 94.
(c) The case that pipes are installed to upper (bottom) of fan unit,keep space of 60mm or more to upper (bottom)of unit.
Note(c)
Fan unit
Note(a)
or m
ore
or m
oreF
Slab
or m
ore
or m
ore
Ceiling
Note(b)
or m
ore
or m
ore
600
1500
650
120015
0-20
0
100- 200
100
2020
450
100
Note(1)The model name label is attached on the lid of the control box.
(1) Indoor units
(a) Ceiling concealed type (SRR)
Models SRR25ZS-W, 35ZS-W
750790(Suspension bolts pitch)
457
2221
500
380
168 10
5
200
30
326
413
55
660(Outlet dimension)
5958
165
120
379935
65 65
2020
370(Su
spen
sion b
olts p
itch)
(Ou
tlet d
imen
sion)
600 o
r less
(Ma
x. dr
ain lif
t)
50
235-265
□120 19
660(Inlet dimension)
160
21
65 65
19
(Inl
et dim
ensio
n)
Air Inlet
16
60 24
167
29.57.528
68.785101
30
Control box
suspension boltHanger plate for
Air outlet
Connector(Accessory)(Installed on site)
F Inspection hole (450 x 450),(320 x 770)
A Gas pipingB Liquid piping
C1 Drain piping
D Hole for wiringE Suspension bolts (M10)
Symbol Content
φ6.35(1/4")(Flare)φ9.52(3/8")(Flare)
Drain pipingC2 (Gravity drainage)
VP25(I.D.25 , O.D.32)
(Used with attached connector)VP25(I.D.25 , O.D.32)
(Used with attached connector)
φ25 x 2
Unit:mm
Wired remote control(Option)
Wireless remote control
Remote control signal receiver
Remote controlsignal receiver
(Cord length 1.8m)
Notes(1)The model name label is attached on the lid of the control box. (2)To connect the wired remote control,
the interface kit (SC-BIKN2-E) is required.
100
450
45075
0
200
100
750
150 or more
770
or
mor
e
or more
100 o
r mor
e
1000 1000
150 or more
320Obstacle
View from top side of the unitObstacle
Obstacle
Rear-intakeCeiling-return type
Space for installation and service
F
E
C 2
D
A
C1
B
2. EXTERIOR DIMENSIONS
Ducted Systems July 2020
mhiaa.com.au ABN 92 133 980 275
Australia: Phone: 1300 138 007NSW & Head Office Block E, 391 Park Road, Regents Park NSW 2143
Victoria 2/15 Howleys Road, Notting Hill VIC 3168
Brisbane 5/26 Flinders Parade, North Lakes QLD 4509
Townsville 1/37 Ross River Road, Mysterton QLD 4812
Western Australia 1/15-17 Capital Road, Malaga WA 6090
mhiheatpumps.co.nz G.S.T. 105-673-620
New Zealand: Phone: 0800 138 007Auckland 698A Great South Road, Penrose, 1061
Mitsubishi Heavy Industries Air conditioners Australia, Pty. Ltd.