Honeywell Fire Systems Group
Honeywell Fire Systems Group
RFX
SLC L1: Det.159 Mod. 159
SLC L2: Det.159 Mod. 159
SLC L3 ~ L10
EIA 485
EIA 232
Up to 96 Programmable Input or Output
RDP Up to 32
Noti-Fire-Net
NCS
4 Set On Board Relay O/P
Honeywell Fire Systems Group
CPU-3030
Honeywell Fire Systems Group
Display
1 2 3 4 5 6 7 8 9 0
Q W E R T Y U I O P
A S D F G H J K L
Lower
Case Z X C V B N M Space
Esc
Enter
*
#
&
/
+
-
(
)
POWER
FIRE ALARM
PRE-ALARM
SECURITY
SUPERVISORY
SYSTEMTROUBLE
OTHEREVENT
SIGNALSSILENCED
POINTDISABLED
CPUFAILURE
FIRE ALARMSCROLL DISPLAY
SECURITYSCROLL DISPLAY
SUPERVISORYSCROLL DISPLAY
TROUBLESCROLL DISPLAY
OTHER EVENTSCROLL DISPLAY
SIGNALSILENCE
DRILLHOLD 2 SEC.
SYSTEMRESET
DISABLEENABLE
PRINTSCREEN
LAMPTEST
F1
NEXTSELECTION
PREVIOUSSELECTION
RECALLLAST
ENTRY
INCREMENTNUMBER
Honeywell Fire Systems Group
Loop Modules
J3
J1
J2
JP1
D33+5V
D32
D28
B+ A+ B- A-SLC
JP2
TB1
JP3SW1
EG
FA
ULT
LCM-320 LEM-320
Honeywell Fire Systems Group
LCM Cables
Honeywell Fire Systems Group
LCM/LEMSLC Connector
Channel B Channel A
Typical Style 4.0
Channel B
Output
Channel A
Return
Typical Style 6.0/7.0
Honeywell Fire Systems Group
AMPS-24(E) Power Supply
TB
1
HOT NEUTRAL EARTH
SLCA SLCB+ - + -
TB
1
CO
M
+24V
CO
M
+5V
AC
CE
SS
OR
IEST
B6
24V
PA
NE
L
24V
GN
D
-485
+485
GN
D
24V
TB
2
0123456
78910 1112 1314
15
SW2
0 SW
3 5 1 2 3 4 5 6 7 8
ON
LE
D9
LE
D8
LE
D10
LE
D1
LE
D2
LE
D3
LE
D4
LE
D6
LE
D5
LE
D7
Honeywell Fire Systems Group
AMPS-24(E) Power Supply
TB
1
HOT NEUTRAL EARTH
SLCA SLCB+ - + -
TB
1
CO
M
+24V
CO
M
+5V
AC
CE
SS
OR
IES
TB
6
24V P
AN
EL
24V
GN
D
-485
+485
GN
D
24V
TB
2
0
1
23456
7
89
10 11 12 131415
SW2
0 SW
3 5 1 2 3 4 5 6 7 8
ON
LE
D9
LE
D8
LE
D10
LE
D1
LE
D2
LE
D3
LE
D4
LE
D6
LE
D5
LE
D7
120 @ 4.5A / 240 VAC @2.25 A
24 V Output (G)
TB6 Output (G)
GROUND FAULT (Y)
10 A Battery FUSE
SLC Address Switch
Setting Switch
LED 1 : AC POWER (G)LED 2 : BATT / CHARGE TROUBLE (Y)LED 3: NOT USEDLED 4 : TROUBLE (Y)
LED 5 : SLCRXA (G)LED 6 : MICROPROCESSOR FAIL (Y)LED 7: SLCTXA (G)LED 4 : TROUBLE (Y)
Battery24 V @ 25 ~ 200 AH
Honeywell Fire Systems Group
Auxiliary Power
APS-6R CHG-120
Honeywell Fire Systems Group
ACM (AEM) – 48 A
A1P1
A1P2
A1P3
A1P4
ACM(AEM)-24AT
ACS Annunciators
Honeywell Fire Systems Group
RPT-WRPT- F
RPT-WF
Repeaters
Honeywell Fire Systems Group
LCD-160 Remote Display
Honeywell Fire Systems Group
ACS Annunciators
NOTIFIER REMOTELCD ANNUNCIATOR ALL SYSTEMS NORMAL12:10P 01/11/01
Hold forStatus
ContrastAdjust
LampTest
Ack/Step
SignalSilence
SystemReset
LCD-80(ACS Mode Only)
0123
45798
6
0123
457
98
6
1 2 3 4 5 6 7 8
ACM-8R LDM-32series
Honeywell Fire Systems Group
ACS Annunciators
SwitchGroup 5
SwitchGroup 6
SwitchGroup 7
SwitchGroup 8
SwitchGroup 1
SwitchGroup 2
SwitchGroup 3
SwitchGroup 4
All AutoManual
Acknowledge
Honeywell Fire Systems Group
Voice Components
LOCALSPEAKERVOLUME
ALL
CALL
AUDIO LEVELALL CALLON LINE
TROUBLE
AUDIOMESSAGEGENERATOR
FIREFIGHTERSTELEPHONE
PAGE MODE
AMG
PAGE
ON LINE
LINETROUBLE
PHONETROUBLE
Honeywell Fire Systems Group
The assembly consists of a back box and a locking door withtwo keys. The back box and door can be ordered separately or asa complete unit. Doors may be hinged right or left. A semi-flush trim ring kit is available for each box size.
Page 19
DR-A4 SBB-A4
Honeywell Fire Systems Group
Page 19
SBB-B4DR-B4
Honeywell Fire Systems Group
Page 20
SBB-C4DR-C4
Honeywell Fire Systems Group
Page 20
SBB-D4DR-D4
Honeywell Fire Systems Group
ABS-4DABS-2D
Honeywell Fire Systems Group