© Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice.
Rethink workload defined Server: HP MoonshotDesigned for the data center, built for the planet
© Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice.
© Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice.2
Contents.
1. Moonshot Overview
2. Moonshot Cartridges detail
© Copyright 2012 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice.
HP Proliant Moonshot Overview
© Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice.4
2014
124,000 MIPS
By 2020
1989
20 MIPs
Cloud
Mobility
Security
Big Data
1972
.004 MIPS
인터넷접속장비및웹트래픽의폭발적증가현재 IT인프라는새로운비즈니스를감당하기에버거움
30
Billion
(300억)
40
Trillion GB
(40조)
… for 8
Billion
(80억)
10
Million
(1천만)
DATA
(1)
(2)
(3)
Devices
Mobile
Apps
(4)
(1) IDC Directions 2013: Why the Datacenter of the Future Will Leverage a Converged Infrastructure, March 2013, Matt Eastwood ; (2) & (3) IDC Predictions 2012: Competing for 2020, Document 231720, December 2011, Frank Gens; (4)
http://en.wikipedia.org
© Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice.5
현재서버는미래 IT 요구사항에적합하지않음전력, 상면, 비용및복잡성에서미래에지속불가능함
New Style of ITTraditional IT
수백만개의 성능수십억개의기기/사용자 비지니스응용프로그램
특화되고무한한인프라
가상화및예측가능한인프라
수백개의 지원수천개의기기/사용자 비지니스응용프로그램
Today’s
ServersPer Year
100-200 억불Datacenter build costs
8 to 10New power plants
200만US Homes of power
used
(1) (2) (3)
Source: HP internal research
© Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice.6
HP 혁신의역사및리더쉽새로운시장및비즈니스기회를리딩해왔습니다.
x86
블래이드x86
랙서버 1stx86
SystemPro ProLiant BladeSystem
HP 엔지니어링
Moonshot
업무최적화서버
한계를뛰어넘는효율성과확장성을위한Workload Defined Server: Moonshot
• 전원, 냉각, 네트워크, 관리기능공유• 최대 45개의핫플러그서버카트리지• 업무별최적화된성능제공
업무최적화서버
© Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice.7
혁신을위한파트너프로그램Moonshot 시스템은새로운개념의혁신, 솔루션및지원을약속합니다.
HP Pathfinder
Innovation
Ecosystem
Moonshot
Concierge
Support
Customer
Need
Analyze
Application
Optimize
Server
Launch
Solutions
4x the Solutions
3x Faster Time to
Innovation
Leading
technology
partnerships
HP Discovery
Lab
Service &
Consulting
Acquire on
your terms$
Solution Builder
program
Community
Expertise
Reference
Architecture
s
© Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice.
HP Moonshot system
© Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice.8
© Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice.9
HP Moonshot 1500 Chassis 전면새로운형태의 IT에대한기반
hot-plug 카트리지 45대
• Single-server = 샤시당 45대독립서버제공
• Quad-server =샤시당 180대독립서버제공
low-latency 스위치 2대• HP Moonshot-45G Switch
Module (45 x1Gb 다운링크)
• HP Moonshot-180G Switch
Module (180 x1Gb 다운링크)
• HP Moonshot-45xGc Switch
Module (45 x10Gb
다운링크)
© Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice.10
HP Moonshot 1500 Chassis 후면새로운형태의 IT에대한기반
HP 공통전원공급기
이중화된 hot-plug 팬모듈 5개
Dual Network Uplinks• HP Moonshot-6SFP 업링크모듈 (6 x10Gb Stackable
Uplinks)
• HP Moonshot-4SFP 업링크모듈 (4 x40Gb Stackable
Uplinks)
HP Moonshot 1500 Chassis
관리모듈
© Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice.11
네트워크 Fabric 연결옵션두대의 low-latency 스위치를통해트래픽분리또는네트워크이중화기능제공
Switch B
Switch A
Servers 1-45
Uplink module B
Uplink Module A
Single servers45 ports
Quad servers 180 ports
Switch B
Switch A
Servers 1-45
Uplink module B
Uplink Module A
© Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice.12
Management fabric여러대의서버를하나의 iLO 네트워크를통해단일플랫폼으로관리
• HP Moonshot 1500 Chassis 관리모듈은일반적인관리인터페이스를통합제공
• 단일 Ethernet 포트사용
• 각서버에 IPMI 및 Serial Console
제공
• 완벽히분리된펌웨어업그레이드서비스제공
• SL-APM 랙관리기능제공
SC SCSC
SCSC
SC SCMgmt.
Hub
Switching
Fabric
Management
PortCooling
Sub-system
Power
Sub-system
Storage
Backup or
cartridge
HP
Moonshot
1500
Chassis
Managemen
t module
SC: Satellite Controller
© Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice.13
HP Insight Cluster Management Utility (CMU)카트리지나외부에서동작가능한리눅스클러스터관리도구
배포
모니터링
제어
빠른탐색및복제제공트리구조배포및확장기능제공
전체서버상태즉시파악화면장애화면확대기능제공커스터마이징가능
GUI 및 CLI 옵션제공쉽고빠른설치지원
Available NOW!
© Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice.14
카트리지서버상세업무목적별최적의 CPU, memory, storage, networking 제공
Web infrastructure, dedicated
hosting, distributed analytics, NoSQL
databases
Video transcoding, gaming, application
delivery, extreme file transfer
Memory caches, in-memory
analytics, science and engineering
applications
Hosted desktop infrastructure,
gaming, content distribution network
(CDN)
Real-time data processing, complex
event processing, IP transcoding
Typical workloadsCompute StorageNetworking Specialized
cores
MemoryProLiant
m300
m350
m400
m700
m710
m800
Density
Web hosting, distributed analytics
ARM 64bit
8
cores/SoC
Dual port
10GbE
/CPU
N/A 64GB 45/4.3
U
180/4.3U
180/4.3U
45/4.3
U
45/4.3
U
180/4.3U
Dual port
10GbE
/CPU
Dual port
1GbE
/CPU
Dual port
1GbE
/CPU
Dual port
1GbE
/CPU
Dual port
1GbE
/CPU +
2D Torus
Local SSD
(NGFF/m.2)
ARM A15
4 cores /
SoC
32GB
8GB/S
oC
C66x DSP
8 cores/
SoC
GPU Iris
Pro +
128MB
eDDR
Xeon E3
4 cores/SoCLocal SSD
(NGFF/m.2)32GB
Atom™ C2750
8 core/SocN/A
N/AAtom™ C2730
8 core/SoC64GB
16GB/S
oC
Local SSD
(NGFF/m.2)
SFF HDD or
SSD32GB
Opteron™ X2150
4 core /SoC32GB
8GB/S
oC
4 x 64GB
iSSDGPU
128 cores/SoC
© Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice.
HP Moonshot ServerCartridge Details
ProLiant m700
Server
ProLiant
Moonshot
Server
(m100)
ProLiant m300
Server
© Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice.16
HP ProLiant m300 서버카트리지소개Web/App Server, Big Data Analytics 용
TM
Intel® Atom Processor
C2750 2.4 GHz/8 core
TM
32G Max Memory
(4) 8GB DDR3 ECC
1600MHz
(2 on front & 2 on back)
500GB or 1TB HDD or SSD,
non-hot-plug, small form factor
x 45 hot-plug servers per chassis
13.10
Enterprise
Linux 6.4
Linux Enterprise
Server 11 SP2
Windows
Server 2012 R2
© Copyright 2014 Hewlett-Packard Development Company, L.P. HP Confidential.17
기존의 1u 1P 서버HP Moonshot System
45 ProLiant m300 servers
ProLiant m300 서버카트리지도입효과Web/App/Big Data 분석업무에최적화
80% 낮은전력소모91% 적은상면사용97% 적은케이블 TCO 절감
50%
45 1U 1P 서버
1 랙 (47u 랙)
4 Kwatts 전력
45 ProLiant m300 서버
1 샤시 (4.3u)
0.8 Kwatts 전력
© Copyright 2014 Hewlett-Packard Development Company, L.P. HP Confidential.18
Moonshot powers HP.com
6Cache
16 HTTP Apache
16Download files
6 대의 Moonshot 샤시< 6kW 총전력사용
< 1 랙이하Browsing: www.hp.com (HP’s web gateway)
Downloads: ftp.hp.com (driver updates )
100%www.hp.com
300만건일일방문수
94%낮은전력소모
89%적은상면사용
(1)
100%ftp.hp.com
© Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice.19
HP ProLiant m700 카트리지소개Hosted Desktop Infrastructure 전용
4개의 APU SoC
4개의 8GB DDR3 ECC
1600MHz 메모리
샤시당 45개의 hot-plug 카트리지(샤시당 180대의데스크탑수용)
iLO 관리프로세서
4개의 32Gb iSSD 또는4개의 64Gb iSSD
*APU = Accelerated processing unit
© Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice.20
HP만이유일하게완벽한원격데스크탑제품군제공
성능및가격
세션/응용프로그램
가상화
가상데스크탑(VDI)
높은그래픽성능이
제공되는가상데스크탑
밀도High
High
Client
Devices
단순사용자
지식사용자
일반사용자 고급사용자
워크스테이션사용자
HP Moonshot
m700
(HDI)
© Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice.
Moonshot Leap 4 Cartridges
© Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice.22
CPU (4) 13W soldered down Intel Atom Avoton / 8 core / 1.7GHz
MEMORY Total of 16GB per CPU – or 2GB/core
(4) Socketed DIMMS – each 8GB, 1600MHz, DDR3 SO-DIMM, ECC
(4) Embedded DRAM – each 8GB, 1600MHz, DDR3 SO-DIMM, ECC
NETWORK Integrated NIC: dual port 2.5GbE per CPU. (Dialed down to 1GbE)
STORAGE NAND Mezz for local Boot – 64G per CPU or 32G per CPU
BOOT 1) Network 2) Local Boot from NAND Mezz
SYSTEM CONFIGS 45 Scott 4 Cartridges, 30 Scott4 Cartridges, 15 Scott4 Cartridges.
POWER Measured Max 60W per Cartridge.
OS Ubuntu 12.04.4, RHEL 6.5, SLES 11 SP3+PLDP for 1GB NIC,
Windows Server 2012, Windows Server 2012 R2
HP ProLiant m350 Moonshot Cartridge
Limited Availablility August 2014
Managed hosting, 병렬연산, HTC 업무용도
180 Servers per Chassis (15A)
© Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice.23
HP Proliant m710 Moonshot Cartridge
CPU 47W soldered down Intel Xeon E3-1284Lv3 4-core 1.8Ghz Haswell (all-core
turbo 2.4Ghz)
MEMORY 4 LV S0DIMM (Non- ECC) plus 8 ECC DRAM down. Total 32GB Max.
NETWORK Integrated NIC: Dual port 10GbE Mellanox CX3 MT27518.
STORAGE Local boot / SATA or PCIe NGFF (M.2).
BOOT 1) Network.
2) Local Boot via SATA or PCIe NGFF (M.2).
SYSTEM CONFIGS a) 45 Anders Cartridges.
b) 15 Anders Cartridges
POWER Cartridge: <70W @ 75% loading
Form Factor Single Wide, Single slot - Gemini Module (6.8” X 6.1”)
OS (SW) Ubuntu 14.04, RHEL 6.5,7.0 w/KVM, SLES 11 SP3 w/KISO/KVM, Windows
Server 2012 R2, CentOS 6.5, 7.0
Launching September 2014
Media Transcoding & Big Data (Investigating), XenApp
Haswell CPU Core + Crystalwell GPU Core
© Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice.24
HP ProLiant m400 Moonshot Cartridge
CPU (1) Applied Micro “Storm” 64-bit ARM , 2.4 GHz / 8 core
MEMORY (4 or 8) DIMMS – Total of 32 or 64GB
each 8GB, 1600MHz, DDR3 UDIMM SO-DIMM ECC
NETWORK Mellanox Connect X3 NIC: dual-port 10GbE
Switch module: (45) 10GbE Downlinks “ComWolff-1X”
Uplink module: (4) 40GbE SFP+ ports “Rook40”
STORAGE (0 or 1) M.2 80mm Flash Module - 120GB, 240GB or 480GB
ROM HP BIOS, uBoot, Headless, no video, no USB
BOOT 1) Direct From M.2 Flash 2) Network 3) software iSCSI (once OS
Supports)
SYSTEM CONFIGS (15, 30, or 45) HP ProLiant m400 Server Cartridges
POWER Processor: 37 – 43W max
Cartridge: <65W typical, 85W TDP with 8 DIMMs
OS Ubuntu 14.04 Preinstalled
2.88TB of memory, 21.6TB of flash storage Per Chassis
Memcached, NoSQL(MongoDB, Cassandra)
© Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice.25
HP ProLiant m800 Server Cartridge
CPU (4) TI 66AK2H12 = (4) ARM A15 cores + (8) C66x DSP cores/processor,
1.0GHz
MEMORY (4) DIMMS – Total of 32GB
8GB/CPU, 1600MHz, DDR3 UDIMM SO-DIMM ECC
NETWORK Integrated NIC: dual port 1GbE per CPI
Switch: HP Moonshot-180G Switch Module
Uplink Module: HP Moonshot-4QSFP+ Uplink Module
STORAGE Via mezzanine: 32GB or 64GB m.2 (2242) per SoC
BOOT 1) Network
2) Local storage via NGFF (32GB or 64GB)
SYSTEM CONFIGS (45) HP ProLiant m800 Server Cartridges w/ 32GB m.2 NGFF
POWER Cartridge: ~70W typical (Preliminary)
OS + DSP tool Ubuntu 13.10 + TI MCSDK (preinstalled)
Launching September 2014
VoIP/LTE, Voice Transcoding, Seismic processing(지질분석), 실시간신호처리4 ARM A15 Cores + 8 TI DSP Cores
© Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice.26
The HP Discovery Lab Network
Investigate, test, and benchmark
applications in a secure and
confidential environment
Houston,
Texas
Purdue
University
Indiana
(education only)
Grenoble,
France
Singapore
New: Purdue and Singapore
© Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice.
감사합니다.
Key Takeaway of HP Moonshot
1. 분산/병렬환경에최적화2. 업무목적별로특화3. 도입비용이아닌 TCO 관점의접근