HYDROCLICK SYSTEM
• Smooth surface
• Clean ability
• Resistance of lining against potable water
• (at chlorination up to 1 ppm)
• Absolute tightness
• No ground water infiltration through concrete wall (at buried tanks)
Currently used systems
• Tiles
• Coatings
• Concrete without further treatment
• Thermoplastic liners
DEMANDS ON POTABLE WATER TANKS
• Potable Water Tanks – general
• Hydroclick system
• Installation
• References
• Limitations
• Approvals
2
Problem:Coating of potable water tanks
Limited service life Contamination of potable water by detached particles
POTABLE WATER TANKS - GENERAL
• Potable Water Tanks – general
• Hydroclick system
• Installation
• References
• Limitations
• Approvals
3
Problems caused by solvent water:
Service life ? Maintenance ? Repair ?
POTABLE WATER TANKS - GENERAL
• Potable Water Tanks – general
• Hydroclick system
• Installation
• References
• Limitations
• Approvals
4
• Product approval acc. to KTW (for potable water)
• Raw material approval DVGW-W270 (for pot. water)
• No deposits on the tank wall
• Easy to clean – high pressure resistance (130bar)
• Good resistance against chlorination up to 3 ppm
(0,5 ppm free chlorine resp. 0,3 ppm ClO2)
• Long service life (PE-pipes 50 years)
• Fast installation / shorter construction times!
• Ventilation gap avoids creation of aggressive condensates
ADVANTAGES OF SYSTEM
• Potable Water Tanks – general
• Hydroclick system
• Installation
• References
• Limitations
• Approvals
5
• extruded - calendared
• max. width: 2000mm
• thickness: 4mm
• material: PE80 blue RAL 5012
12-15mm
~ 2000mm
50mm
HYDROHYDROCLICKCLICK liner
HYDROHYDROCLICKCLICK profile
HYDROCLICK SYSTEM
• Potable Water Tanks – general
• Hydroclick system
• Installation
• References
• Limitations
• Approvals
6
HYDROHYDROCLICKCLICK profile
coextruded with PEHD-el layer
Distance studs(height ~ 9mm)
Click stud(adjusted to the Click profile)
HYDROCLICK SYSTEM
• Potable Water Tanks – general
• Hydroclick system
• Installation
• References
• Limitations
• Approvals
7
Protective film
Perforation strip (on both sides 50mm)
HYDROCLICK SYSTEM
• Potable Water Tanks – general
• Hydroclick system
• Installation
• References
• Limitations
• Approvals
8
Easy installation:
• No extensive preparation before installation
• Tiles and coatings may be left in the tank if they are not loose
• Second chamber can be operated without special efforts (no dust or odours)
INSTALLATION
• Potable Water Tanks – general
• Hydroclick system
• Installation
• References
• Limitations
• Approvals
9
Wall installation
Step 1:
Sheet with click-studs is clicked into the profile which is mechanically fixed to the wall
INSTALLATION
• Potable Water Tanks – general
• Hydroclick system
• Installation
• References
• Limitations
• Approvals
10
Step 2:Second sheet is clicked into the profilePreparation of the welding area
Wall installation
INSTALLATION
• Potable Water Tanks – general
• Hydroclick system
• Installation
• References
• Limitations
• Approvals
11
Step 3:
Extrusion weldingDVS optimized
Wall installation
INSTALLATION
• Potable Water Tanks – general
• Hydroclick system
• Installation
• References
• Limitations
• Approvals
12
Ground-wall-transition
INSTALLATION
• Potable Water Tanks – general
• Hydroclick system
• Installation
• References
• Limitations
• Approvals
13
Wall connection / Margin sections
INSTALLATION
• EPDM bar• Stainless steel bar• Sealing strip
Connection withPE sheet strip
PE profilefixed
• Potable Water Tanks – general
• Hydroclick system
• Installation
• References
• Limitations
• Approvals
14
Drain section remains
Wall-ground-transition with 45° chamfer
INSTALLATION
• Potable Water Tanks – general
• Hydroclick system
• Installation
• References
• Limitations
• Approvals
15
Thermoformed elements
Lining of columns
INSTALLATION
• Potable Water Tanks – general
• Hydroclick system
• Installation
• References
• Limitations
• Approvals
16
Anchor element
INSTALLATION
• Potable Water Tanks – general
• Hydroclick system
• Installation
• References
• Limitations
• Approvals
17
Project: Brig Switzerland
REFERENCES / PROJECTS
• Potable Water Tanks – general
• Hydroclick system
• Installation
• References
• Limitations
• Approvals
18
Project: Vernate Switzerland
REFERENCES / PROJECTS
• Potable Water Tanks – general
• Hydroclick system
• Installation
• References
• Limitations
• Approvals
19
Project: Leuggern Switzerland
REFERENCES / PROJECTS
• Potable Water Tanks – general
• Hydroclick system
• Installation
• References
• Limitations
• Approvals
20
REFERENCES / PROJECTS
• Potable Water Tanks – general
• Hydroclick system
• Installation
• References
• Limitations
• Approvals
Project: Leuggern Switzerland
21
Project: Völkingen Germany
REFERENCES / PROJECTS
• Potable Water Tanks – general
• Hydroclick system
• Installation
• References
• Limitations
• Approvals
22
Project: Oberschlierbach Austria
REFERENCES / PROJECTS
• Potable Water Tanks – general
• Hydroclick system
• Installation
• References
• Limitations
• Approvals
23
REFERENCES / PROJECTS
• Potable Water Tanks – general
• Hydroclick system
• Installation
• References
• Limitations
• Approvals
24
System limitations of the HYDROCLICK system
• Applicable up to a max. temperature change of 10 °C
• Max. application temperature: 30°C
• Not recommended for back pressure build up
between concrete and liner
• Not UV resistant
LIMITATIONS
• Potable Water Tanks – general
• Hydroclick system
• Installation
• References
• Limitations
• Approvals
25
APPROVALS
• Potable Water Tanks – general
• Hydroclick system
• Installation
• References
• Limitations
• Approvals
26
AGRU Kunststofftechnik GmbHIng.-Pesendorfer-Str. 31
A-4540 Bad HallAustria / EU
www.agru.at
T +43 (0) 7258 790 - 0F +43 (0) 7258 3863E [email protected]
Subject to errors of typesetting, misprints and modifications. Illustration are generic and for reference only!
THANK YOU