Page 1: HYDROBOX - EUROINSTAL

0-100°C

TI

0-100°C

TI

0-100°C

THW5B

sonda

D

TI

0-100°C

TI

0-100°C

BEP

TI

0-100°C

TI

0-100°C

vs

TI

0-100°C

TI

0-100°C

0-6 Bar

PI

TB1

HYDROBOX

LICHID/GAZ

ECB1

ST

THW6

sonda

THW7

sonda

unitate exterioara

alimentare

electrica

rezistenta

auxiliara

alimentare

electrica

verificati pozitia

reala a conductelor

de tur si retur

in manualul

de instalare

COLECTOR

DISTRIBUITOR

INCALZIRE IN PARDOSEALA

APA CALDA SANITARA

VANA ANTIOPARIRE

PREPARARE ACM

PENTRU POMPA DE CALDURA

BOILER

INTRARE APA RECE

RECIRCULARE ACM

PI

0-6 Bar

KP2

FS

PI

0-6 Bar

PUHZ-SHW80VAA

PUHZ-SHW80YAA

PUHZ-SHW112VAA

PUHZ-SHW112YAA

PUHZ-SHW112YHA

PUHZ-SHW140YHA

PUHZ-SHW230YHA

Diametre recomandate conducte apa:Pompe de caldura 8-14kw - conducta de plecare recomandata Dn32/Cupru 35/PPR50Pompa de caldura 23kw - conducta de plecare recomandata Dn40/Cupru 42/PPR63

8

8

11,2

11,2

11,2

14

23

1 faza

3 faze

1 faza

3 faze

3 faze

3 faze

3 faze

1

9

2

9

10

Vana pentru preparare ACM10

Timpul de reacție al servomotorului trebuie să fie mai mic de 10 secunde.Exemple de vane deviatoare compatibile:Vana in 3 puncte (SPDT) CALEFFIDiametru 1"-model 6443-66Vane in 2 puncte (SPST) ESBEDiametru 1"-corp vana VRG231 Dn25 + Servomotor ARA635Diametru 1"-corp vana VRG322 Dn25 + Servomotor ARA635Diametru 1 1/2 "-corp vana VRG231 Dn32 + Servomotor ARA645Diametru 1 1/2 "-corp vana VRG322 Dn32 + Servomotor ARA645

11

4

Senzor de boiler - THW5B - Cod de achizitie PAC-TH011TK2-E

4

Senzori circuit de incalzire - THW6/7 - Cod de achizitie set -PAC-TH011-E5

5

Boiler cu serpentina extinsa pentru utilizare cu pompe de caldura.Serpentina boilerului trebuie sa fie dimensionata cu suprafata minima de 0,25mp/kW.11

13

Butelie de egalizare a presiunii sau acumulator?

Pompa de căldură are nevoie de un volumminim de apă pentru a realiza degivrarea iarna.Dacă acest volum se atinge, se poate optapentru BEP.Volumul de apă luat în calcul este cel dincircuitul de producere a agentului termic la carese adaugă volumul de apă din circuitul deconsum, dacă pompa de circulație estecomandată de pompa de căldură și existăcircuite care rămân tot timpul deschise (se valua în calcul doar apa din aceste circuite, nu șiapa din circuitele cu vane de închidere).Dacă nu se atinge acest volum minim de apă seva opta pentru un acumulator, ales pentru aatinge acest volum. Un acumulator mai mare de100 de litri poate afecta negativ eficiențapompei de căldură, atunci cănd se opteazăpentru temperatură autoadaptivă.

13

PUHZ-SHW80VAA

PUHZ-SHW80YAA

PUHZ-SHW112VAA

PUHZ-SHW112VHA

PUHZ-SHW112YAA

PUHZ-SHW112YHA

PUHZ-SHW140YHA

PUHZ-SHW230YHA

Continut

minim de

apa [litri]

29

29

43

43

43

43

55

94

Unitate exterioara

12

PUHZ-SHW80VAA

PUHZ-SHW80YAA

PUHZ-SHW112VAA

PUHZ-SHW112VHA

PUHZ-SHW112YAA

PUHZ-SHW112YHA

PUHZ-SHW140YHA

PUHZ-SHW230YHA

Debit de apa

[mc/h]

Unitate exterioara

Pompa de circulatie va fi aleasa inconformitate cu tabelul de mai jos.Inaltimea de pompare depinde decomplexitatea instalatiei.

12

6

Senzor de temperatura de camera pe fir TH1 - Cod de achizitie -PAC-SE41TS-E (conectact la CN20) sauControler fara fir PAR-WT50R-E + receptor de semnal PAR-WR51R-E (pentru varianta aceasta trebuie să activați SW1-8 și să conectașireceptorul la portul CNRF)

6

Alimentarea electrica a unitatilor exterioare:7

7

PUHZ-SHW80VAA

PUHZ-SHW80YAA

PUHZ-SHW112VAA

PUHZ-SHW112VHA

PUHZ-SHW112YAA

PUHZ-SHW112YHA

PUHZ-SHW140YHA

PUHZ-SHW230YHA

Alimentare

electrica

exterioara

1 faza

3 faze

1 faza

1 faza

3 faze

3 faze

3 faze

3 faze

Unitate exterioara

Disjunctor

recomandat

[A]

32

16

32

40

16

16

16

32

Cablu de

alimentare

3x4mm2

5x1,5mm2

3x4mm2

3x6mm2

5x1,5mm2

5x1,5mm2

5x1,5mm2

5x4mm2

Cablu de

comunicare

3x1,5mm2

3x1,5mm2

3x1,5mm2

3x1,5mm2

3x1,5mm2

3x1,5mm2

3x1,5mm2

3x4mm2

Alimentare

electrica

1 faza

1 faza

3 faze

3 faze

Curent

maxim

[A]

9

9

26

13

13

13

Cablu de

alimentare

2x2,5mm2

2x2,5mm2

2x4mm2

4x1,5mm2

4x1,5mm2

4x1,5mm2

EHSC-VM2D

EHSC-VM6D

EHSC-YM9D

EHSE-YM9ED

ERSC-VM2D

ERSE-MED

ERSE-YM9ED

Unitate interioara

3 faze

1 faza

1 faza

Putere

[kW]

2

6

9

9

9

2

Disjunctor

recomandat

[A]

16

16

32

16

-

16

16

Alimentarea electrica a rezistentei auxiliare a unitatii interioare:8

8

-- -

*Impamantarea este considerata separata.

14

Atentie! Dimensionarea cablurilor este in sarcina proiectantului de instalatii electrice, care va lua in calcul si lungimea efectiva a acestora.Valorile din tabel au caracter de recomandare, dar nu tin locul proiectului tehnic de instalatii electrice.

Atentie! Dimensionarea conductelor este in sarcina proiectantului de instalatii termice.Valorile indicate mai sus au caracter de recomandare, dar nu tin locul proiectului tehnic de instalatii termice.

3

Conducte de refrigerant: PUD-SHWM80/100/120/140:Ø12,7/6,35mm, PUHZ-SHW80/112/140: Ø15,88/9,52mm; PUHZ-SHW230: Ø25,4/12,7mm3

Nota 1: Pompa de căldură lucrează cu atât maieficient cu cât temperatura agentului termic depe tur este mai coborâtă.Acest deziderat poate fi atins:

1. Setând temperatura agentului termic lavaloare joasă (în cazul în care pe parteade consum se poate lucra cu temperaturăjoasa, repectiv dispunem de încălzire înpardoseală)

2. Setând temperatura agentului termic cavariabilă în funcție de temperaturaexterioară

3. Setarea pompei de caldură petemperatură autoadaptivă, caz în careaceasta va regla temperatura de pe tur înfuncție de temperatura exterioară șitemperatura interioară (este nesarămontarea unui senzor de temperaturăinterioară - vezi punctul 6)

Dacă se optează pentru temperatură variabilăajustați capetele curbei de compesare în acordcu aplicația, respectiv: coborâți valoarea maximădacă aveți încălzire în pardoseală.

Nota 2: Daca distribuitorul de încălzire înpardoseală conține o vană de amestec esterecomadat ca poziția acesteia să rămânăcomplet deschisă, iar reglajul de temperatură săse realizeze la pompa de căldură.

Nota 3: Asigurați-vă că debitul de agent termicdin circuitul de consum nu este mai mare decâtcel de pe partea pompei de căldură.(temperatura pe tur înainte și dupa BEP ar trebuisă fie egală, în caz contrar micșorați debitulpompei de circulație pe partea de consum).

PUD-SHWM140YAA 143 faze

1 faza9

2x2,5mm2EHSC-VM2D 216

1 faza9

2x2,5mm2ERSD-VM2D 216

1 faza9

2x2,5mm2EHSD-VM2D 216

TBO.11 2 3 4 5 6

OUT1 OUT5 OUT4

TBO.21 2 3 4 5 6

TBO.31 2 3 4 5 6 7 8

OUT10 OUT16 OUT11 OUT12

TBO.51 2 3 4 5 6 7 8

TBI.11234567

8

IN1 IN2 IN3 IN4

FTC6

SW

1

ON

OFF

12

34

56

78

SW

2

ON

OFF

12

34

56

78

SW

3

ON

OFF

12

34

56

78

SW

4

ON

OFF

12

34

56

SW

5

ON

OFF

12

34

56

78

Cazan: fară / cuTemperatură maximă apă: 55 / 60 °CBoiler ACM: Fără/ CuRezistentă de imersie: Fără / CuRezistență integrată în unitatea interioară: Fără / CuFuncționaritate rezistență integrată: Încălzire /Încălzire + ACMTip unitate exterioară: Split/ MonoblocComandă wireless: Fără / Cu

Termostat Zona 1 (IN1): STOP închis / STOP deschisFluxostat 1 (IN2) : DEFECT închis / DEFECT deschisRestricție rezistență integrată: Inactivă / ActivăMod răcire: Inactiv / ActivBack-up cu unitate interioară(x eroare UE): Inactivă / ActivăSeparator hidraulic: Fără / CuControl 2 zone termice: Inactiv /ActivContor putere: Fără / Cu

Protecție supratemperatură ACM: 75°C / 88°CControl autoadaptiv: Inactiv / Activ

Unități exterioare multiple: Inactivă/ ActivăUnități exterioare multiple: Save/Master-- -- --Doar unitate interioară (URGENȚĂ): Inactivă/ActivăDoar rezistența electrică (URGENȚĂ): Normal / ResistențaDoar cazanul (URGENȚĂ): Normal / Rezistența

TBO.41 2 3 4 5 6 7 8

OUT15 OUT13 OUT9 OUT8 BHT BC OUT6 OUT7

TBI.21234567

8

IN5 IN6 IN7 IN10

TBI.31234567

8

IN8 IN9 IN11 IN12

TBI.51234567

8

TBI.41234567

8

INA1

TBI.61234567

8

OUTA1

SW

6

ON

OFF

12

34

5

Senzor de presiune: Fără / CuSemnal de ieșire analogică 0-10 V(OUTA1) : Inactiv / Activ

OUT2 OUT3

THW6 THW7 THW8 THW9 THWB1 THW10

TH

W5B

CNW5

(BU)

KP2

230Vac

1 A m

ax

Vana deviatoare ACM

Regleta 265

N

L1

230Vac

0.1 A max

ACM

vana cu 3 căi

tip: intoarecere

cu arc

Regleta 245 6

OUT4

NL2 L1

Încă

lzire

230Vac

0.1 A max

ACM

tip: SPDT

(ex. Caleffi 6443-66)

Regleta 4

SV

OUT13

vana cu 3 căivana cu 3 căi

4 5 6

NL2L1

Încă

lzire

230Vac

0.1 A max

ACM

tip: SPST

Regleta 2

SV

OUT4 OUT4

TH

W6

TH

W7

(G

R)

(BK)

Termostat Zona 2 (IN6): STOP închis / STOP deschisFluxostat 2 (IN3) și 3 (IN7): DEFECT închis / DEFECT deschis

-- -- --Contor nergie electrică: Fără / CuMod încălzire: Inactiv / ActivControl ON/OFF vană cu 2 căi: Inactiv /ActivSchimbător ACM: Imersie / ExternContor putere: Fără / Cu

14

Nul

Nul

Nul

32

FS

Putere termică

circuit frigorific

[kW]

Compatibilitate

2kW 2kW 6kW 9kW 9kW 9kW

Alimentare

electrică

exterioară

1 faza 1 faza 1 faza 3 faze 3 faze 3 faze

EHSC-VM2D EHSC-VM6D EHSC-YM9D EHSE-YM9EDERSC-VM2D ERSE-MED ERSE-YM9ED

Unitate interioară

Funcție

Rezistență

interioară

Unitate exterioară

Putere

Faze

-

-

1

2

2kW

1 faza

EHSD-VM2D

încălzire

2kW

1 faza

ERSD-VM2D

încălzire/

răcire

PUD-SHWM140VAA 141 faza

PUD-SHWM120YAA 123 faze

PUD-SHWM120VAA 121 faza

PUD-SHWM100YAA 103 faze

PUD-SHWM100VAA 101 faza

PUD-SHWM80YAA 83 faze

PUD-SHWM80VAA 81 fazaÎncălzire

Doar încălzire

încălzire încălzire încălzire încălzire

încălzire/

răcire

încălzire/

răcire

încălzire/

răcire

Doar încălzire

Doar încălzire

Doar încălzire

Doar încălzire

Doar încălzire

Doar încălzire

Doar încălzire

Încălzire/răcire

Încălzire/răcire

Încălzire/răcire

Încălzire/răcire

Încălzire/răcire

Încălzire/răcire

Încălzire/răcire

Încălzire

Încălzire

Încălzire

Încălzire

Încălzire

Încălzire

Încălzire

Încălzire

Încălzire

Încălzire

Încălzire

Încălzire

Încălzire

Încălzire

Încălzire

Reversibilă

Încălzire

Reversibilă

Încălzire

Reversibilă

Încălzire

Reversibilă

Încălzire

Reversibilă

Încălzire

Reversibilă

Încălzire

Încălzire

Încălzire

Încălzire

Încălzire

Încălzire

Încălzire

Încălzire

Încălzire

Încălzire

Încălzire

Încălzire

Încălzire

Reversibilă ReversibilăÎncălzire

PUD-SHWM140YAA

PUD-SHWM140VAA

PUD-SHWM120YAA

PUD-SHWM120VAA

PUD-SHWM100YAA

PUD-SHWM100VAA

PUD-SHWM80YAA

PUD-SHWM80VAA 1 faza

3 faze

25

16

3x2,5mm2

5x1,5mm2

3x1,5mm2

3x1,5mm2

1 faza

3 faze

30

16

3x4mm2

5x1,5mm2

3x1,5mm2

3x1,5mm2

1 faza

3 faze

32

16

3x4mm2

5x1,5mm2

3x1,5mm2

3x1,5mm2

1 faza

3 faze

40

16

3x6mm2

5x1,5mm2

3x1,5mm2

3x1,5mm2

PUD-SHWM140YAA

PUD-SHWM140VAA

PUD-SHWM120YAA

PUD-SHWM120VAA

PUD-SHWM100YAA

PUD-SHWM100VAA

PUD-SHWM80YAA

PUD-SHWM80VAA0,540 .. 1,374

0,540 .. 1,374

0,858 .. 2,064

0,858 .. 2,064

0,858 .. 2,064

0,858 .. 2,064

0,858 .. 2,064

0,858 .. 2,064

0,612 .. 1,374

0,612 .. 1,374

0,612 .. 1,926

0,864 .. 1,926

0,864 .. 1,926

0,864 .. 1,926

1,074 .. 2,214

1,722 .. 3,954

PUD-SHWM140YAA

PUD-SHWM140VAA

PUD-SHWM120YAA

PUD-SHWM120VAA

PUD-SHWM100YAA

PUD-SHWM100VAA

PUD-SHWM80YAA

PUD-SHWM80VAA

55

55

47

47

38

38

29

29

Spațiu liber necesar atunci când sunt obstacole sau mai multe exterioare

Parametru

a

b

c

Dimensiuni

100

350

500

Spațiu liber necesar pentru

service unitate exterioară

Parametru

a

b

c

d

Dimensiuni

200

150

500

500

Spațiu liber necesar pentru

service unitate interioară

În furnitura unității interioare găsiți inclus un card de memorie care trebuie introdus în slotuldestinat lui, de pe placa electronică (întrerupeți alimentarea electrică înainte).Acest card este util pentru a înregistra parametrii de funcționare ai pompei de căldură spre a-iputea examina ulterior pe calculator.

Dacă veți dori sa accesați pompade căldură prin internet utilizândserviciul nostru gratuit Melcould,este nesarar să instalați interfațaopțională MAC-567IF-E pe portulCN105.

Dacă veți dori sa conectați pompade căldură la un sistem BMS cuprotocol de comunicare Modbussau BACnet, puteți face astautilizând interfața opționalăPROCON A1M, conectată la portulCN105.

Montarea unității exterioare la înalțimesuficientă, departe de zonele de circulațiepermite condensului să fie evacuat liber dinunitate, fără pericolul înghețării acestuia peo conducta de evacuare condens.Dacă însă soluția pentru care se optează estecolectarea condensului, pe conductă cu firîncălzitor, unitatea exterioară poatecomanda firul încălzitor, utilizând un releucorespunzător, cu ajutorul conectoruluiopțional PAC-SE60RA-E.Unitatea exterioară va alimenta releul atuncicând începe degivrarea și o va menținepentru 15min.

Releu pentru comanda pompă decirculație.14

Capacitatea unităților poatesă fie afectată de vânturi

puternice, astfel că se poate sănu atingă puterea maximă.

Mai puțină influență a vântului faceca unitățile să lucreze la capacitate maximă.

· Instalați unitatea la o cotă suficient de mareastfel încât să preveniți problemele cauzate deînghețarea apei evacuate.

· Instalați într-o locație unde înghțarea apei sănu provoace riscuri de accidentare.

· Instalați în poziție verticală astfel încât apa săse scurgă.

Instalare corectă Instalare greșită Instalare greșită

Instalare greșităInstalare corectă

Dacă unitatea esteînclinată apa nu se poatescurge, iar gheațadeteriorează exterioara.

Apa ajungepe zonede circulație

Apa îngheață șioamenii pot aluneca

Poziționațiunitățile unalângă alta

Unitatea dejos îngheață

Instalare corectă

Instalare corectă Instalare corectă

Instalare greșită Instalare greșită· Instalați la o înălțime suficientă pentru a preveni ca

zăpada să acopere unitatea precum și efecteleadverse provocate de înghețarea apei evacuate.

· Instalați deasupra înălțimii stratului maxim de zăpadă.· Chiar dacă unitatea este instalată corect, apa care se

scurge poate forma țurțuri ce trebuie să fie înlăturațiperiodic.

· Instalați unitatea astfel încât să evitați efectele zăpeziiviscolite, precum și căderile de zăpadă de pe acoperiș.

Unitea poate să fie acoperită dezăpadă din cauza viscolului sauatunci când zăpada cade de peacoperiș.

Unitatea poate să fie deterioratăde căderile de țurțuri

Înălțimea minimăde instalare trebuiesă fie cu 20cmdeasupra stratuluide zăpadă.

Instalare greșită

Unitatea poate săfie acoperită cuzăpadă dacă soclulnu este suficient deînalt.

Glugiîmpotrivazăpezii

Fără glugi deprotecție În zonele cu

căderei masive dezăpadă instalațiglugi pentru a nuaspira fulgi dezăpadă.

*Impamantarea este considerata separata.

Placa electronicăa unității exterioare

SV1

0,5-2mm2

Maxim 10mMaxim 1A230V

ReleuAlimentareelectrică

Cabluîncălzitor

Nu conectați racordul de drenaj pe unitateaexterioară, decât în situația în care optați

pentru fir încălzitor, atfel apa va îngheța peracord și va bloca evacuarea apei.

AutoCAD SHX Text
VE
AutoCAD SHX Text
VE
AutoCAD SHX Text
siguranta
AutoCAD SHX Text
siguranta
AutoCAD SHX Text
cu apa avand:
AutoCAD SHX Text
pH intre 6,5 si 8
AutoCAD SHX Text
calciu<=1100mg/l
AutoCAD SHX Text
clor<=100mg/l
AutoCAD SHX Text
fier/mangan<=0,5mg/l
AutoCAD SHX Text
incarcati instalatia

Recommended