. , . , .33,
/ : +7 (383) 218-82-43 http://www.promhimteh.ru e-mail: [email protected] . +7 913 913 91 90
e-mail: [email protected]
Anfangsdaten/ Pump data sheet/
Kunde/User Abt./Shop.
Pos./Item
1.1 , 3/F rderstrom/Capacity min, m3/h
, 3/F rderstrom/Capacity norm, m3/h
, 3/F rderstrom/Capacity max, m3/h
1.2 , .F rderh he/Head, m
, .F rderh he/Head, m
, . m.F rderh he/Head, m
1.3 ,Druck am Saugstutzen/Suction pressure, bar
1.4 ,Druck am Druckstutzen/Discharge pressure, bar
1.5 ,NPSHvorh. / NPSHav. , m
-
1.6 (, .)Pumpenart (vertikal, horisontal, tauchpumpe usw.)Pump type (vertical, horisontal, submersible pump, etc.)
1.7 ( ),Tauchtiefe (f r vertikale Pumpen), mSubmergence depth (for vertical pumps), m
-
2.F rdermedium/Medium
2.1chemische Zusammensetzung/chemical composition
2.2 . , % ./ .Feststoffgehalt, % Vol./GewichtSolid particles content, % vol./mass
2.2.1Benennungen/name
,Abmessungen, mmSize,
2.3 , 0
Temperatur, 0
Temperature, 0
, / 3Dichte, kg/dm3density, kg/dm3
2.5 ,Viskosit t, cStviscosity, cSt
, 0bei Temperatur, 0at temperature, 0
2.6Zus tzlichen Daten des F rdermediumsadditional information con. Pumped medium
-
3.Wellenabdichtung/shaft seal
4. : /Aufstellung: im Raum/unter Schirmdach/im FreienInstalation: indoor/under cover/outdoor
4.1Exschutzforderungen/explosion protection requirement
5.Antrieb/Driver
6.
7.Pumpenanzahl/Quantity of pumps
8.Bemerkungen/Notes
1
-
-
!
!
! : !
( )!
!
, , ,
!
, , " ".
" ".
, , " ".
Nikkiso Pumps Europe GmbH Nikkisostrasse � D-63674 Altenstadt / Hessen
.: +49 (0) 6047-96 49-0 : +49 (0) 6047-9649-99
: www.nikkiso-pumps.com
- (2- )
© Nikkiso Pumps Europe - 07/2005
Nikkiso .
2
-
1. 1.1
1.2
1.3
2. 2.1
2.2 ,
2.3 (ATEX 100a )
3. - 3.1.
3.2.
3.3. ( )
3.4.
3.5.
4. 4.1
4.2
5. 5.1 : A & B -
5.2 : C & D -
5.3 : F, G, J & K
5.4 : F, G, J & K -
6. - 6.1
6.2
6.3
6.4
7. E-
7.1
7.2
7.3
8.
3
-
1. 1.1
- -
( ) ( )
( )
4
- 1.2
Nikkiso .
70°C. 1.3
. ,
.
:
-
A1, A2, A3, A5 B1, B2, B3, B5 L1, L2, L3 M1, M2, M3
A & B ( )
C1, C2, C3, C4, C5 D1, D2, D3, D5 H1, H2
C & D ( )
F1, F2, F3, F4 G1, G2, G3, G5 J1, J2, J3, J4 K1, K2, K3, K4 N1, N2, N3
F & K
( A & B)
1.3.1
H N 21A - A1
(1 )
(2 )
( )
5
-
2.
HINWEIS
GEFAHR
, .
:
- , - , - , , , .
.
, , . ( EN 60204- 1).
.
, , , , , ,
, , , .
2.1
, , .
- ,
; - , ,
Ex- / ; -
/ .
2.2 ,
, , .
2.2.1 . , ,
, . 2.2.2 ,
/ , ,
. , , .
6
-
2.3
(ATEX 100a )
(EN 50 018) EN 50 019.
2.3.1 (EN 60 079 - 14). , ,
(EN 60 079 - 17).
2.3.2 , , / .
2.3.3 ,
EN 50 018 13.2. 2.3.4 IEC 38. 2.3.5 EExde �
(EExd EN 50 018). .
2.3.6 , (
, : , , ( 2.2.2)).
2.3.7 ,
, . EN 50 018, EN 50 019.
2.3.8 ,
, , EN 50 018, .
2.3.9 ,
, , . 30 .
7
-
3. - 3.1 :
EN 50 014
( ) EN 50 018
( "d") EN 50 019
( "e")
:
-
II2G - EExd II CT* II2G - EExd II CT6
II2G - EExe II CT6 II2G - EExd II CT6
IP65 IP55 IP65* IP65
* !
3.2 .
,
.
GEFAHR
. !
3.3 ( )
8
-
3.3.1
( 2.3.9)
. ,
, .
,
.
9
-
3.3.2 A & B
!
: - S1 / S2
Pt100 PTC ( )
-
4 - 20 mA
-
� -
TERMINAL CONNECTIONS
BLACK ( ) RED W HITE ( )
( ) ( )
CONNECTION TERMINALS TO BE USED REQUIRED TORQUE
FOR IGHTENNIG T
MOTOR LEAD
U; V; W ( 12) 3 Nm
WINDING PROTECTION
S1; S2; (M6) 3 Nm
ROTOR CHAMBER PT100 IF ISTALLED PT100,
1; 2 ( 3) 2 Nm
E-MONITOR INTERN -
3; 4; 5; 6; 7; 8; 9 ( 3) 2 Nm
FREE
6 ( 3) 2 Nm
E-MONITOR INTERNAL -
BLACK; RED; WHITE ; ;
2 Nm
REMOTE INDICATION, NEUTRAL ,
31 2 Nm
REMOTE INDICATION, AXIAL ,
32 2 Nm
REMOTE INDICATION, RADIAL ,
33 2 Nm
REMARS / TERMINAL BOX DESIGN MEETS ZONE 1 / IP 65 ENCLOSURE REQUIREMENTS
1 / IP
65 FINAL ZONE / ENCLOSURE IS DEPENDANT ON THE DESIGN OF THE CABLE GLAND AND/OR PLUG USED
/ .
3.3.3 C & D
: - S1 / S2
Pt100 PTC ( )
- .
Option 4 - 20 mA
4 - 20 mA
-
� C D -
TERMINAL CONNECTIONS
BL ACK ( ) RED W HITE ( )
( ) ( )
CONNECTION TERMINALS TO BE USED REQUIRED TORQUE FOR TIGHTENNIG
MOTOR LEAD
U; V; W ( 12) 12 Nm
WINDING PROTECTION
S1; S2; (M6) 3 Nm
ROTOR CHAMBER PT100 IF ISTALLED PT100,
1; 2 ( 3) 2 Nm
E-MONITOR INTERN -
3; 4; 5; 6; 7; 8; 9 ( 3) 2 Nm
FREE
6 ( 3) 2 Nm
E-MONITOR INTERNAL -
BLACK; RED; WHITE
; ;
2 Nm
REMOTE INDICATION, NEUTRAL ,
31 2 Nm
REMOTE INDICATION, AXIAL ,
32 2 Nm
REMOTE INDICATION, RADIAL ,
33 2 Nm
REMARS / TERMINAL BOX DESIGN MEETS ZONE 1 / IP 65 ENCLOSURE REQUIREMENTS
1 / IP 65
FINAL ZONE / ENCLOSURE IS DEPENDANT ON THE DESIGN OF THE CABLE GLAND AND/OR PLUG USED
/ .
10
- 3.3.4 F & K ( G & J)
- A & B
!
4 - 20 mA
-
�
: - S1 / S2
Pt100 PTC ( )
- .
CONNECTION TERMINALS TO BE USED REQUIRED
TORQUE FOR
TIGHTENNIG E-MONITOR INTERN -
3; 4; 5; 6; 7; 8; 9 ( 3) 2 Nm
FREE
6 ( 3) 2 Nm
E-MONITOR INTERNAL -
BLACK; RED; WHITE ; ;
2 Nm
REMOTE INDICATION, NEUTRAL ,
31 2 Nm
REMOTE INDICATION, AXIAL ,
32 2 Nm
REMOTE INDICATION, RADIAL ,
33 2 Nm
F-,G-, K-, J-
REMARS / TERMINAL BOX DESIGN MEETS ZONE 1 / IP 65 ENCLOSURE REQUIREMENTS
1 /
IP 65 FINAL ZONE / ENCLOSURE IS DEPENDANT ON THE DESIGN OF THE CABLE GLAND AND/OR PLUG USED
/ .
CONNECTION TERMINALS TO BE USED
REQUIRED TORQUE FOR TIGHTENNIG
MOTOR LEAD
U; V; W; X; Y; Z; (16) 24 Nm
WINDING PROTECTION
S1; S2; (M6) 3 Nm
ROTOR CHAMBER PT100 OR UNUSED PT100,
C1; C1; (M6) 3Nm
Pt100
( ) ( )
BLACK
( ) RED
W HITE ( . )
TERMINAL CONNECTIONS
REMARS / TERMINAL BOX DESIGN MEETS ZONE 1 / IP 65 ENCLOSURE REQUIREMENTS
1 / IP 65
FINAL ZONE / ENCLOSURE IS DEPENDANT ON THE DESIGN OF THE CABLE GLAND AND/OR PLUG USED
/
11
-
3.4
, ( 2.3.8).
,
EN 50 262.
EN 50 262 . 3.5
IEC529-EN 60 529 - IP55 IP65. , .
,
, , . , .
. 4. 4.1
. Nikkiso Pumps Europe (NPE) :
,
(1 )
!
IP 65 NBR- . , NPE
5-6 . 4.2
, Nikkiso. /
.
.
, , .
:
5.1, 5.2 5.3,
(Item No.) . .
12
: Nikkiso Pumps Europe GmbH .: +49 (0)6047 - 96 49 0 Nikkisostrasse : +49 (0)6047 - 96 49 99 : [email protected] D-63674 Altenstadt www.nikkiso-pumps.com
-
13
-
5.
5.1 : A & B -
()
()
CO
NN
ECTI
ON
S O
F IT
EM
ITEM
(
)
()
14
- ITEM
DIN 24250
REMARKS
1 833.1 BODY 2 833.2 COVER 3 833.3 E-MONITIO
COVER -
4 835 TERMINAL ASSY 5 412.5 O-RING
6 400.3 COVER CASKET IP55 (IT); IP65 (NBR) 7 914.10 BOLT M8 8 . 8.8 8 930.1 SPRING WASHER
8 8
9 930.2 SPRING WASHER 8
8
10 901.4 BOLT M8 8 . 8.8 11 914.11 BOLT M6 6 12 900.2 EARTH BOLT M6 6 13 554.1 WASHER 6 6 14 160 COVER 15 920.4 NUT M6 6 16 930.4 SPRING WASHER
6 6
17 554.2 WASHER 6,6 6,6 18 836 TERMINAL
(BARTEC) (BARTEC)
19 400.5 BODY CASKET (NBR)
IP65 ONLY / IP65
CONNECTION TERMINALS TO BE USED REQUIRED TORQUE
FOR TIGHTENNIG MOTOR LEAD
U; V; W ( 12) 3 Nm
WINDING PROTECTION
S1; S2; (M6) 3 Nm
ROTOR CHAMBER PT100 IF ISTALLED PT100,
1; 2 ( 3) 2 Nm
E-MONITOR INTERN -
3; 4; 5; 6; 7; 8; 9 ( 3) 2 Nm
FREE
6 ( 3) 2 Nm
E-MONITOR INTERNAL -
BLACK; RED; WHITE
; ;
2 Nm
REMOTE INDICATION, NEUTRAL ,
31 2 Nm
REMOTE INDICATION, AXIAL ,
32 2 Nm
REMOTE INDICATION, RADIAL ,
33 2 Nm
1:2,5 Scale
Weight
Made
11.08.00 H. Nohl
Checked
14.08.00 C. Plum
Approved
14.08.00 W. Meier
NIKKISO NON SEAL ® PUMP A & B
TERMINAL BOX FOR A & B - MOTORS
. 2 Rev.
05.06.03 H. Nohl . Ser. - No
1 1
Page
15
-
5.2 : C & D -
()
()
CO
NN
ECTI
ON
S O
F IT
EM
ITEM
(
)
(
)
16
- ITEM
DIN 24250
REMARKS
1 833.1 BODY 2 833.2 COVER 3 833.3 E-MONITIO
COVER -
4 835 TERMINAL ASSY 5 412.5 O-RING
6 400.3 COVER CASKET A
IP55 (IT); IP65 (NBR)
7 400.4 COVER CASKET B
IP55 (IT); IP65 (NBR)
8 914.10 BOLT M8 8 . 8.8 9 930.1 SPRING WASHER
8 8
10 901.3 BOLT M8 IANGULA(TR R)
8 . 8.8
11 930.2 SPRING WASHER 8
8
12 901.4 BOLT M8 6 . 8.8 13 930.3 SPRING WASHER
8 8
14 900.2 EARTH BOLT M6 6 15 554.1 WASHER 6 6 16 160 COVER 6 17 920.4 NUT M12 12 18 930.4 SPRING WASHER
12 12
19 554.2 WASHER 13 13 20 920.5 NUT M6 6 21 930.5 SPRING WASHER
6 6
22 554.3 WASHER 6,6 6,6 23 836 TERMINAL
(BARTEC) (BARTEC)
24 400.5 BODY CASKET (NBR)
IP65 ONLY / IP65
CONNECTION TERMINALS TO BE USED REQUIRED TORQUE
FOR TIGHTENNIG MOTOR LEAD
U; V; W ( 12) 12 Nm
WINDING PROTECTION
S1; S2; (M6) 3 Nm
ROTOR CHAMBER PT100 IF ISTALLED PT100,
1; 2 ( 3) 2 Nm
E-MONITOR INTERN -
3; 4; 5; 6; 7; 8; 9 ( 3) 2 Nm
FREE
6 ( 3) 2 Nm
E-MONITOR INTERNAL -
BLACK; RED; WHITE
; ;
2 Nm
REMOTE INDICATION, NEUTRAL ,
31 2 Nm
REMOTE INDICATION, AXIAL ,
32 2 Nm
REMOTE INDICATION, RADIAL ,
33 2 Nm
1:2,5 Scale
Weight
Made
11.08.00 H. Nohl
Checked
14.08.00 C. Plum
Approved
14.08.00 W. Meier
NIKKISO NON SEAL ® PUMP C & D
TERMINAL BOX FOR C & D - MOTORS
. 2 Rev.
05.06.03 H. Nohl . Ser. - No
1 1
Page
17
-
5.3 : F, G, J & K
18
- ITEM
DIN 24250
REMARKS
1 833.1 BODY 2 833.2 COVER 3 835 TERMINAL ASSY 4 412.5 CASKET 5 400.3 CASKET 6 914.10 BOLT M8 8 . 8.8 7 930.2 SPRING WASHER
8 8
8 901.4 BOLT M8 8 . 8.8 9 554.1 WASHER 6,6 6,6 10 900.2 EARTH BOLT M6 6 11 920.6 NUT M16 16 12 920.7 NUT M16 16 13 920.5 NUT M6 6 14 554.3 WASHER 6,6 6,6 15 930.5 SPRING WASHER
8 8
16 920.4 NUT M16 16 17 554.2 WASHER 17 17 18 930.4 SPRING WASHER
16 16
19 920.5 NUT M6 6 20 914.11 BOLT M8 8 21 554.4 WASHER 8,4 8,4 22 930.5 SPRING WASHER
8 8
23 901.5 SCREW M4 4 24 400.5 CASKET IP65 ONLY /
IP65
CONNECTION TERMINALS TO BE USED
REQUIRED TORQUE FOR TIGHTENNIG
MOTOR LEAD
U; V; W; X; Y; Z; (16) 24 Nm
WINDING PROTECTION
S1; S2; (M6) 3 Nm
ROTOR CHAMBER PT100 IF ISTALLED PT100,
C1; C1; (M6) 3Nm
1:4 Scale
-
Weight
Made 17.05.01 H. Nohl
Checked
17.05.01 P. Tersi
Approved
17.05.01 W. Meier
NIKKISO NON SEAL ® PUMP F & K
TERMINAL BOX FOR F & K - MOTORS
. Rev.
NKK NKK - No
1 1
Page
19
-
6. -
Nikkiso - , .
/
. ,
- .
6.1
NIKKISO - .
5 :
(3) = (1) = : (2) = :
: ( ) : ( ) : ( : ) : : ( ) - (
) : ( Nikkiso)
6.2 ( )
( ,
)
( ,
)
- Nikkiso .
- 3 - 3
20
.
-
6.3
, , . .
6.4
,
( ).
.
.
(
).
, ! !
.
, ! !
21
-
7. - 7.1
8 ( ), ( ). - .
: ( ) � ( !) �
( ).
7.2
, - ,
, .
7.2.1 4-20 mA
7.2.2 0-5 V
3 2
1
3 2
1
3
1
2
3 2
1
22
-
7.3 - , 7.3.1 -
, , ,
. 7.3.1.1
4-20 A
0-5
A A 4,00 0,00 1 14,88 3,40 2 16,64 3,95 3 17,44 > 17,44 * < 18, 40 4,20 > 4,20 * < 4,50
18,40 18,40 4,50 4,50 20,00 5,00
7.3.1.2
4-20 A
0-5
A A 4,00 0,00 1 14,88 3,40 2 15,84 3,70 3 16,64 > 16,64 * < 18, 40 3,95 > 3,95 * < 4,50
18,40 18,40 4,50 4,50 20,00 5,00
* , , .
,
.
23
-
7.3.2 - :
24
- 8.
25
-
26