LIGHTING CONSTRUCTION MANUAL
SERVICES
Go to SECTION INDEX Back to MAIN INDEX
1-4-1-1
1 4 1-1 0E
LIGHTING
10500-A4-1-4-1-1
DESCRIPTIONTYPE PAGE TYPE DESCRIPTION PAGE
SERVICES INDEXB 10.12.12
VOLUME FOLDER ISSUEPAGE
Approved Ergon
Approved Energex
Checked
Drawn
Date
Date
Date
Date
A ORIGINAL ISSUE
HARD COPY UNCONTROLLED
C COPYRIGHT 2002 ENERGEX
ABN 50 087 646 062
Ergon Energy Corporation Limited
C COPYRIGHT 2002 ERGON ENERGY
ABN 40 078 849 055
ENERGEX Corporation Limited
ENERGEX or Ergon Energy
without written permission from
reproduced in part or whole
This document must not be
REFERENCE DRAWING ENERGEX
REFERENCE DRAWING ERGON
EE DRWG NO:
EGX DRWG NO:
C. Noel
F. Zaini
P. Relf / A. Bletchly
L. Burton / T. Borg
01/05/18
01/05/18
01/05/18
01/11/10
C 19.03.14
D 06.03.17
Underground From Overhead System - Notes & Materials
1-4-2-1
1-4-2-2
1-4-2-3
1-4-3-1
1-4-3-2
1-4-4-1
1-4-10-1
OVERHEAD CONSTRUCTION
SOHSL
SOHSL
UNDERGROUND CONSTRUCTION
SUGSL
SUGSL
/SBM
SOHSLL
1-4-4-2
1-4-5-1
1-4-6-1
1-4-7-1
1-4-8-1
1-4-9-1
1-4-11-1
1-4-11-2
1-4-2-5
1-4-2-6
1-4-2-7
1-4-2-4
1-4-12-1
1-4-12-2
1-4-15-1
1-4-16-1
1-4-16-2
Construction Type Guide - Services Overhead - Ergon
Construction Type Guide - Services Underground - Ergon
Construction Type Guide - Services Underground - Ergon
Construction Type Guide - Services Underground - Ergon
Construction Type Guide - Services Overhead - Energex
Construction Type Guide - Services Underground - Energex
Construction Type Guide - Services Underground - Energex
Single or 3 Phase 25mm† LVABC from LVABC Mains
To Streetlight - Materials
Single or 3 Phase 25mm† LVABC from LVABC Mains
To Streetlight - Construction
Single or 3 Phase 25mm† LVABC from Open Wire
Mains to Streetlight - Materials
Single or 3 Phase 25mm† LVABC from Open Wire
Mains to Streetlight - Construction
Single or 3 Phase 25mm† LVABC Service Looping
Steel / Concrete Streetlight Poles Material & Const.
Single or 3 Phase 25mm† LVABC Service Looping
Wood Streetlight Poles Material & Const.
Major & Minor Road 16mm† & 4mm† Neutral
Screened Cable at LV Pillar Material & Const.
SBM Steel Pole from LV Pit Single & 3 Phase
Material & Const.
SUGSLL Major / Minor Rd Cable Looping from LV Pit
Materials & Const.
Service Cable Details
Typical Unmetered UG Supply
For Non Standard Luminaire
Typical UnmeteredUG Supply
For Non Standard Luminaire
Major & Minor Road BIG Pole UG Supply
Typical Installation
Major & Minor Road BPM Pole UG Supply
Typical Installation
Major & Minor Road Streetlight Service from Pillar
Underground From Overhead System - ConstructionSPTSL
E 17.04.18
SOH SL 225 ABC/W
SERVICE
SOH = Service overhead
TYPE
SL = Streetlight
EXAMPLE:-
EXAMPLE:-
SERVICE CABLE
225 = 2x25mm ABC
425 = 4x25mm ABC
STREETLIGHT POLE TYPE
W = Wood
(Omit where steel or
concrete pole used)
MAINS CONDUCTOR
2
2
2
2
2
TYPE SERVICE CABLE
EXAMPLE:-
EXAMPLE:-
SOH = Service overhead
SERVICE
SLL = Streetlight looping 225 = 2x25mm ABC
425 = 4x25mm ABC
W = Wood
(Omit where steel or
concrete pole used)
STREETLIGHT POLE TYPE
2
2
2
2
A
A
ABC = LVABC 95mm
Al = Aluminium conductors
Cu = Copper conductors
STREETLIGHT SERVICE FITTINGS - CONSTRUCTION TYPE
Type shown within dashed box
appears on relevant construction
detail drawings in this manual.
Type shown within dashed box
appears on relevant construction
detail drawings in this manual.
LOOPING STREETLIGHT SERVICE FITTINGS - CONSTRUCTION TYPE
VOLUME FOLDER ISSUEPAGE
A
HARD COPY UNCONTROLLED
C COPYRIGHT 2002 ENERGEX
Ergon Energy Corporation Limited
ABN 50 087 646 062
C COPYRIGHT 2002 ERGON ENERGY
ENERGEX Corporation Limited
ABN 40 078 849 055This document must not be
reproduced in part or whole
without written permission from
ENERGEX or Ergon Energy
EE DRWG NO:
EGX DRWG NO:
J. Brooks
R. English
D. Taylor / B. Oyegoke
L. Burton / T. Borg
14/10/10
14/10/10
14/10/10
14/10/10
NOTE:
Service cable NOT included.
Refer CONSTRUCTION PRACTICES
Dwg. 1-3-2-1
NOTE:
Service cable NOT included.
Refer CONSTRUCTION PRACTICES
Dwg. 1-3-2-1
SOHSL225 ABC/W = Overhead service fittings, streetlight, suit 2x25mm service cable to LVABC mains, wood pole.
SOHSL425 Al = Overhead service fittings, streetlight, suit 4x25mm service cable to aluminium mains. (steel or conc. pole)
SOH SLL 425W
SOH SLL225W = Overhead service fittings, streetlight looping, suit 2x25mm ABC service cable, wood pole.
SOH SLL425 = Overhead service fittings, streetlight looping, suit 4x25mm ABC service cable. (steel or conc. pole)
1-4-2-1
1 4 2-1 0A
LIGHTINGSERVICES - ERGON ENERGY ONLY
CONSTRUCTION TYPE GUIDE
OVERHEAD
10500-A4-1-4-2-1
5 83 8025 1
NIL
SUG SL/PIL
SERVICE
SUG = Service underground SL = Streetlight PIL = LV Pillar
TYPE
EXAMPLE:-
A
SERVICE
SUG = Service underground
TYPE
EXAMPLE:-
A
and minor road
BPM and BIG major
SLL = Streetlight looping
TO / FROM
LOOPING STREETLIGHT SERVICE FITTINGS - UNDERGROUND - CONSTRUCTION TYPE
lid and junction box/enclosure
PIT = Tee-off to pole from pit, includes pit,
EXAMPLE:- SUGSLL/PIT = Underground service pit and fittings, streetlight looping, pit to pit.
SUGSLL/JB = Underground service junction box/enclosure only, streetlight looping, pit to pit (pit & lid supplied & installed by others)
LOCATION
SUGSL/PIL = Underground service fittings, streetlight, at LV pillar.
(Pit & lid supplied & installed by others)
junction box/enclosure only
JB = Tee-off to pole from pit, includes
detail drawings in this manual.
appears on relevant construction
Type shown within dashed box
detail drawings in this manual.
appears on relevant construction
Type shown within dashed box
STREETLIGHT SERVICE FITTINGS - UNDERGROUND - CONSTRUCTION TYPE
PIT SIZE
SUG SLL/PIT4
1-4-2-2
1 4 2-2 0C
LIGHTINGSERVICES - ERGON ENERGY ONLY
CONSTRUCTION TYPE GUIDE
UNDERGROUND
10500-A4-1-4-2-2
5 83 8025 2
NILB 15.03.16
4
C 16.08.16
B = Round Class B
VOLUME FOLDER ISSUEPAGE
Approved Ergon
Approved Energex
Checked
Drawn
Date
Date
Date
Date
A ORIGINAL ISSUE
HARD COPY UNCONTROLLED
C COPYRIGHT 2002 ENERGEX
ABN 50 087 646 062
Ergon Energy Corporation Limited
C COPYRIGHT 2002 ERGON ENERGY
ABN 40 078 849 055
ENERGEX Corporation Limited
ENERGEX or Ergon Energy
without written permission from
reproduced in part or whole
This document must not be
REFERENCE DRAWING ENERGEX
REFERENCE DRAWING ERGON
EE DRWG NO:
EGX DRWG NO:
C. Noel
F. Zaini
P. Relf / A. Bletchly
L. Burton / T. Borg
19/04/17
19/04/17
01/04/17
14/10/10
SERVICE
SUG = Service underground
EXAMPLE:-
Code shown within dashed box
appears on relevant construction
detail drawings in this manual.A
TYPE
SL = Street Light
STREETLIGHT SERVICE FITTINGS - UNDERGROUND - SBM POLE - CONSTRUCTION CODE
SBM =
POLE TYPE
Slip base mounted
SUG SL/SBM/PIT
PIT =
JB =
Tee-off to pole from pit, includes pit,
lid and junction box/enclosure
LOCATION
NOTE:
Tee-off to pole from pit, includes
junction box/enclosure only
(Pit & lid supplies & installed by others)
SUGSL/SBM/JB = Underground service junction box/enclosure only, street light, slip base mounted, pit to pit (pit & lid supplied & installed by others)
VOLUME FOLDER ISSUEPAGE
A
HARD COPY UNCONTROLLED
C COPYRIGHT 2002 ENERGEX
Ergon Energy Corporation Limited
ABN 50 087 646 062
C COPYRIGHT 2002 ERGON ENERGY
ENERGEX Corporation Limited
ABN 40 078 849 055This document must not be
reproduced in part or whole
without written permission from
ENERGEX or Ergon Energy
EE DRWG NO:
EGX DRWG NO:
J. Brooks
R. English
D. Taylor / B. Oyegoke
L. Burton / T. Borg
14/10/10
14/10/10
14/10/10
14/10/10
SERVICE
SUG = Service underground
EXAMPLE:-
Code shown within dashed box
appears on relevant construction
detail drawings in this manual.A
TYPE
SL = Street Light
STREETLIGHT SERVICE FITTINGS - UNDERGROUND - SBM POLE - CONSTRUCTION CODE
SBM =
POLE TYPE
Slip base mounted
PIT =
JB =
Tee-off to pole from pit, includes pit,
lid and junction box/enclosure
LOCATION
NOTE:
Tee-off to pole from pit, includes
junction box/enclosure only
(Pit & lid supplies & installed by others)
These are the only allowable
options for SBM poles
Single Phase
PHASE
3 = 3 Phase
These are the only allowable
options for SBM poles
Three Phase
SUG SL/SBM3PIT
SUGSL/SBM3JB = Underground service junction box/enclosure only, 3 phase, street light, slip base mounted, pit to pit (pit & lid supplied & installed by others)
1-4-2-3
1 4 2-3 0A
LIGHTINGSERVICES - ERGON ENERGY ONLY
CONSTRUCTION CODE GUIDE
UNDERGROUND
10500-A4-1-4-2-3
5 83 8025 3
NIL
SERVICE
SL = Streetlight
TYPE
EXAMPLE:-
Adetail drawings in this manual.
appears on relevant construction
Type shown within dashed box
STREETLIGHT SERVICE UNDERGROUND FROM OVERHEAD - CONSTRUCTION TYPE
SPT SL 16C2 P/ABC
SPT = Service Pole TerminationSUITS SERVICE CABLE
16C2 = 16mm† NS 2 Core
CABLE GUARD
MAINS CONDUCTOR
ABC = LV ABC 95mm†
P = Polymeric guard
M = Metal guard
AL = Aluminium conductors
Cu = Copper conductorsDwg 1-3-2-1
Refer Construction Practices
Servie cable not included.
SPTSL16C2P/ABC = Service pole termination, streetlight suits 16mm† NS 2 core cable, polymeric cable guard, LVABC 95mm† mains.
1-4-2-4
1 4 2-4 0A
LIGHTINGSERVICES - ERGON ENERGY ONLY
CONSTRUCTION TYPE GUIDE
UNDERGROUND
10500-A4-1-4-2-4
NIL
NIL
VOLUME FOLDER ISSUEPAGE
Approved Ergon
Approved Energex
Checked
Drawn
Date
Date
Date
Date
A ORIGINAL ISSUE
HARD COPY UNCONTROLLED
C COPYRIGHT 2002 ENERGEX
ABN 50 087 646 062
Ergon Energy Corporation Limited
C COPYRIGHT 2002 ERGON ENERGY
ABN 40 078 849 055
ENERGEX Corporation Limited
ENERGEX or Ergon Energy
without written permission from
reproduced in part or whole
This document must not be
REFERENCE DRAWING ENERGEX
REFERENCE DRAWING ERGON
EE DRWG NO:
EGX DRWG NO:
C. Noel
F. Zaini
P. Relf / A. Bletchly
L. Burton / T. Borg
19/04/17
19/04/17
01/04/17
16/08/16
NOTES:
All metalwork that passes through or into wood shall
be greased for the entire length that may come into
contact with the wood.
2.
1.
Hook service to wood pole
Clamp strain to service hook
Streetlight
Steel/Conc Pole
Streetlight
Wood Pole
3
Phase
1
Phase
3
Phase
1
Phase
2
2
2 4
4
2 2
2
2 4
4
2
QTY
DESCRIPTIONASSY
MATERIAL
800-1
802-1
804-1
805-1 End cap - push on 25mm ABC2
801-6 Fuse holder 100A (service) to bracket 1 3 1 3
801-5 1 3 1 3Cartridge fuse link 80A HRC
1 1--
802-6 Bracket (service fuse) to wood pole 1 1 1 1
Service fuse bracket position is diagrammatic only.
Fit to suit direction of service.
VOLUME FOLDER ISSUEPAGE
A
HARD COPY UNCONTROLLED
C COPYRIGHT 2002 ENERGEX
Ergon Energy Corporation Limited
ABN 50 087 646 062
C COPYRIGHT 2002 ERGON ENERGY
ENERGEX Corporation Limited
ABN 40 078 849 055This document must not be
reproduced in part or whole
without written permission from
ENERGEX or Ergon Energy
EE DRWG NO:
EGX DRWG NO:
J. Brooks
R. English
D. Taylor / B. Oyegoke
L. Burton / T. Borg
14/10/10
14/10/10
14/10/10
01/10/10
1-4-3-1
1 4 3-1 0A
LIGHTINGSERVICES
SINGLE OR 3 PHASE 25mm† LVABC FROM
LVABC MAINS TO STREETLIGHT - MATERIAL
10500-A4-1-4-3-1
5 83 8026 1
NIL
NOTE: Refer SERVICES Dwg. 1-4-10-1
Service cable not included. Refer CONSTRUCTION PRACTICES Dwg. 1-3-2-1
2 4 2 4804-2 6-35mm Aluminium / 4-35mm Copper Thru Connector
Connector I.P.C. 25/95mm† main to 6/35mm† tap
F
F
F
F
F
F
F
F
STREETLIGHT END
SUPPLY END
(Steel/Conc./Wood)
streetlight
cable toPole
Light
Street
streetlight poles
steel and concrete
Eyebolt & eyenut
Assy 800-1
00
(wood pole only)
75 Minis neutral
Fully ribbed core
Pole
Mains
Assy 802-1
Assy 802-1
00
75
Assy 804-1
Drip loop
Assy 802-6
Assy 801-6
Assy 801-5
F
F
F
Construction Type
(Fittings)SOHSL
1-4-5-1 or 1-4-6-1.
service. Refer drawing
Streetlight pole looping
1-4-3-2
1 4 3-2 0B
LIGHTINGSERVICES
SINGLE AND 3 PHASE 25mm† LVABC FROM
LVABC MAINS TO STREETLIGHT - CONSTRUCTION
10500-A4-1-4-3-2
5 83 8026 2
NIL
Assy 804-2 (Energex)
Assy 805-1 (Ergon Energy)
B 07.12.12
start of looping service.
Service fuse required at the
NOTE:
VOLUME FOLDER ISSUEPAGE
Approved Ergon
Approved Energex
Checked
Drawn
Date
Date
Date
Date
A ORIGINAL ISSUE
HARD COPY UNCONTROLLED
C COPYRIGHT 2002 ENERGEX
ABN 50 087 646 062
Ergon Energy Corporation Limited
C COPYRIGHT 2002 ERGON ENERGY
ABN 40 078 849 055
ENERGEX Corporation Limited
ENERGEX or Ergon Energy
without written permission from
reproduced in part or whole
This document must not be
REFERENCE DRAWING ENERGEX
REFERENCE DRAWING ERGON
EE DRWG NO:
EGX DRWG NO:
C. Noel
F. Zaini
P. Relf / A. Bletchly
L. Burton / T. Borg
24/04/13
24/04/13
04/04/13
01/10/10
2.
1. All metalwork that passes through or into wood shall
be greased for the entire length that may come into
contact with the wood.
NOTES:
Streetlight
Steel/Conc Pole
3
Phase
1
Phase
2
AR
AR
2
2 4
4
AR
AR
2 2
AR
AR
2
2 4
4
AR
AR
2
3
Phase
1
Phase
Streetlight
Wood Pole
Hook service to wood pole
Clamp strain to hook
Saddle (20mm) to wood pole
Bracket cable support to crossarm
Connector tap-off bare aluminium main
Connector tap-off bare copper main
QTY
DESCRIPTIONASSY
MATERIAL
805-1
804-7
804-6
803-6
803-1
802-1
800-1 - - 1 1
801-5 Cartridge fuse link 80A HRC 1 3 1 3
801-6 1 3 1 3Fuse holder 100A (service) to bracket
802-6 Bracket (service fuse) to wood pole 1 1 1 1
End cap - push on 25mm† ABC
Service fuse bracket position is diagrammatic only.
Fit to suit direction of service.
VOLUME FOLDER ISSUEPAGE
A
HARD COPY UNCONTROLLED
C COPYRIGHT 2002 ENERGEX
Ergon Energy Corporation Limited
ABN 50 087 646 062
C COPYRIGHT 2002 ERGON ENERGY
ENERGEX Corporation Limited
ABN 40 078 849 055This document must not be
reproduced in part or whole
without written permission from
ENERGEX or Ergon Energy
EE DRWG NO:
EGX DRWG NO:
J. Brooks
R. English
D. Taylor / B. Oyegoke
L. Burton / T. Borg
14/10/10
14/10/10
14/10/10
01/10/10
1-4-4-1
1 4 4-1 0A
LIGHTINGSERVICES
SINGLE OR 3 PHASE 25mm† LVABC FROM
OPEN WIRE MAINS TO STREETLIGHT - MATERIAL
10500-A4-1-4-4-1
5 83 8027 1
NIL
NOTE: Refer SERVICES Dwg. 1-4-10-1
Service cable not included. Refer CONSTRUCTION PRACTICES Dwg. 1-3-2-1
804-2 6-35mm Aluminium / 4-35mm Copper Thru Connector
F
F
F
F
F
F
F
F
F
SUPPLY END
STREETLIGHT END
Eyebolt & eyenut
steel and concrete
streetlight poles
(Steel/Conc./Wood)
Street
Light
Pole
Assy 800-1
Assy 802-1
00
75 Min
(wood pole only)
Cable to
streetlight
Fully ribbed core
is neutral
Assy 802-1
Mains
Pole
Assy Selection
804-6 or 7
Assy 803-6
(300 intervals)
Construction Type
(Fittings)SOHSL
NOTE:
Service fuse required at the
start of looping service.
F
F
Assy 801-5
Assy 801-6
Assy 802-6
F
Assy 803-1
(300 Intervals)
Streetlight pole looping
service. Refer drawing
1-4-5-1 or 1-4-6-1.
VOLUME FOLDER ISSUEPAGE
A
HARD COPY UNCONTROLLED
C COPYRIGHT 2002 ENERGEX
Ergon Energy Corporation Limited
ABN 50 087 646 062
C COPYRIGHT 2002 ERGON ENERGY
ENERGEX Corporation Limited
ABN 40 078 849 055This document must not be
reproduced in part or whole
without written permission from
ENERGEX or Ergon Energy
EE DRWG NO:
EGX DRWG NO:
J. Brooks
R. English
D. Taylor / B. Oyegoke
L. Burton / T. Borg
14/10/10
14/10/10
14/10/10
01/10/10
1-4-4-2
1 4 4-2 0A
LIGHTINGSERVICES
SINGLE OR 3 PHASE 25mm† LVABC FROM
OPEN WIRE MAINS TO STREETLIGHT - CONSTRUCTION
10500-A4-1-4-4-2
5 83 8027 1
NIL
Assy 805-1 (Ergon Energy)
Assy 804-2 (Energex)
F
F
F
F
F
F
ASSY DESCRIPTION
802-1
805-1
QTY
Eyebolt positions are diagrammatic only.
Fit to suit direction of service.
1.
NOTE:
Assy 805-1
at end of
cable run
Fully ribbed core
is neutral
Street
Light
Pole
Cable to terminal
panel & luminaire
Street
Light
Pole
Incoming
Service
Assy 802-1
Assy 802-1
To continue
where required
Clamp strain to hook
1
Phase
3
Phase
22
2 4End cap - push on 25mm ABC2
(Fittings)SOHSLL
Construction Type
MATERIAL
VOLUME FOLDER ISSUEPAGE
A
HARD COPY UNCONTROLLED
C COPYRIGHT 2002 ENERGEX
Ergon Energy Corporation Limited
ABN 50 087 646 062
C COPYRIGHT 2002 ERGON ENERGY
ENERGEX Corporation Limited
ABN 40 078 849 055This document must not be
reproduced in part or whole
without written permission from
ENERGEX or Ergon Energy
EE DRWG NO:
EGX DRWG NO:
J. Brooks
R. English
D. Taylor / B. Oyegoke
L. Burton / T. Borg
14/10/10
14/10/10
14/10/10
01/10/10
1-4-5-1
1 4 5-1 0A
LIGHTINGSERVICES
SINGLE OR 3 PHASE 25mm† LVABC SERVICE LOOPING
STEEL / CONCRETE STREETLIGHT POLES
10500-A4-1-4-5-1
5 83 8028 1
NIL
F
F
F
F
F
F
F
F
MATERIAL
ASSY
800-1
802-1
805-1
DESCRIPTION
QTY
Assy 800-1
SOHSLL CONSTRUCTION
Hook service to wood pole
Clamp strain to hook
End cap - push on 25mm ABC
To continue
where required
- Fittings
Street
Light
Pole
1
Phase
3
Phase
2
2
2 4
2
2
Assy 802-1
Assy 805-1
at end of
cable run
Assy 802-1
Assy 800-1
Incoming
Service
Cable to
Streetlight
Street
Light
Pole
Fully ribbed core
is neutral
NOTES:
All metalwork that passes through or into wood
shall be greased for the entire length that may
come into contact with the wood.
Service hook/eyebolt positions are diagrammatic
only. Fit to suit direction of service.
2.
1.
2
VOLUME FOLDER ISSUEPAGE
A
HARD COPY UNCONTROLLED
C COPYRIGHT 2002 ENERGEX
Ergon Energy Corporation Limited
ABN 50 087 646 062
C COPYRIGHT 2002 ERGON ENERGY
ENERGEX Corporation Limited
ABN 40 078 849 055This document must not be
reproduced in part or whole
without written permission from
ENERGEX or Ergon Energy
EE DRWG NO:
EGX DRWG NO:
J. Brooks
R. English
D. Taylor / B. Oyegoke
L. Burton / T. Borg
14/10/10
14/10/10
14/10/10
01/10/10
1-4-6-1
1 4 6-1 0A
LIGHTINGSERVICES
SINGLE OR 3 PHASE 25mm† LVABC SERVICE LOOPING
WOOD STREETLIGHT POLE
10500-A4-1-4-6-1
5 83 8029 1
NIL
SUGSL CONSTRUCTION
F
F
F
F
F
F
F
F
ASSY
801-1
DESCRIPTION QTY
- Fittings
Cartridge fuse link 32A HRC
LV Pillar
Assy 801-1 to top tunnel
Connect neutral
Caution tape
in Conduit
Cable installed
and foundation
BIG or BPM pole
Panel
Terminal
1
MATERIAL - AT PILLAR
1838-1 Termination 16mm† & 4mm† N/S cable
as req’d
streetlight pole location
Major or Minor Road
Assy 838-1F
875-1 1SL32A label for service fuse
for service from pillar details
Refer Dwg 1-4-15-1
Note:
1-4-7-1
1 4 7-1 0B
LIGHTINGSERVICES - ERGON ENERGY ONLY
MAJOR & MINOR ROAD
16mm† & 4mm† NEUTRAL SCREENED CABLE AT LV PILLAR
10500-A4-1-4-7-1
5 83 8030 1
NILB 10.01.13
F
Protection Cover
Polymeric Cable
VOLUME FOLDER ISSUEPAGE
Approved Ergon
Approved Energex
Checked
Drawn
Date
Date
Date
Date
A ORIGINAL ISSUE
HARD COPY UNCONTROLLED
C COPYRIGHT 2002 ENERGEX
ABN 50 087 646 062
Ergon Energy Corporation Limited
C COPYRIGHT 2002 ERGON ENERGY
ABN 40 078 849 055
ENERGEX Corporation Limited
ENERGEX or Ergon Energy
without written permission from
reproduced in part or whole
This document must not be
REFERENCE DRAWING ENERGEX
REFERENCE DRAWING ERGON
EE DRWG NO:
EGX DRWG NO:
C. Noel
F. Zaini
P. Relf / A. Bletchly
L. Burton / T. Borg
24/04/13
24/04/13
04/04/13
01/10/10
MATERIAL
ASSY DESCRIPTION QTY
1
F
Construction Type
and foundation
SBM pole, adaptor
Roadway
Construction Manual, TRENCHING.
1. For applicable regional conduit depths, refer Underground
NOTES:
To Luminaire
F
F
trenchin
g d
etail
Refer re
gio
nal
Caution tape
F
F
831-1
F
location as req’d
Streetlight pole
F
F
F
(Refer Note 2)
Slip Base Connection
Protection Cover
Polymeric Cable
SUG SL/SBM
831-2
867-1
867-2
Connection SBM pole to pit - junction box only (1 phase)
Connection SBM pole to pit - junction box only (3 phase)
panel
Terminal
F
refer drawing 1-5-9-10
2. For slip base connection and crimping details
Connection SBM pole to pit - including pit, lid & JB (1 phase)
Connection SBM pole to pit - including pit, lid & JB (3 phase)
SUG SL/SBM/3
1-4-8-1
1 4 8-1 0C
LIGHTINGSERVICES
SBM STEEL POLE FROM LV PIT
SINGLE & THREE PHASE
10500-A4-1-4-8-1
5 83 8077 1
4927-A4-10.4,6 & 11B
I.I No 2422178
2C 4mm† cable
I.I. No 1542919
1C 6mm† earth cable
I.I. No 2400260
2C 4mm† N/S cable
Installed in conduit:
VOLUME FOLDER ISSUEPAGE
Approved Ergon
Approved Energex
Checked
Drawn
Date
Date
Date
Date
A ORIGINAL ISSUE
HARD COPY UNCONTROLLED
C COPYRIGHT 2002 ENERGEX
ABN 50 087 646 062
Ergon Energy Corporation Limited
C COPYRIGHT 2002 ERGON ENERGY
ABN 40 078 849 055
ENERGEX Corporation Limited
ENERGEX or Ergon Energy
without written permission from
reproduced in part or whole
This document must not be
REFERENCE DRAWING ENERGEX
REFERENCE DRAWING ERGON
EE DRWG NO:
EGX DRWG NO:
C. Noel
F. Zaini
P. Relf / A. Bletchly
L. Burton / T. Borg
01/05/18
01/05/18
01/05/18
01/10/10
21.11.16
Refer note 2
3. Allow a minimum of 1m length of cable in pit for maintenance
4. Refer drawing 1-3-10-1 for location of pit relative to pole
refer note 4
Pit location
908-1
907-1 Connection SBM pole to pit - including pit (Type B), lid & JB (1 phase)
Connection SBM pole to pit - including pit (Type B), lid & JB (3 phase)
10.04.18C
ASSY DESCRIPTION QTY
1
Construction Type
F
F
F
F
F
F
F
Caution tape
833-1
SUGSLL
F
looping cables
Incoming & outgoing
F
F
column
panel in
To terminal
in Conduit
Cable installed
location as req’d
Streetlight pole
and foundation
BIG or BPM pole
Panel
Terminal
in pit for maintenance purposes.
Allow minimum of 1m excess cables
trenchin
g d
etail
Refer re
gio
nal
NOTE:
Construction Manual, TRENCHING.
1. For applicable regional conduit depths, refer Underground
833-5 1
1
ASSY DESCRIPTION QTY
MATERIAL - Pit, lid and junction box/enclosure
MATERIAL - Junction box/enclosure
Junction box / enclosure & cable insect protected
833-2
LV pit and lid type 4
LV pit and lid type 2
833-5 Junction box / enclosure & cable insect protected
Pit and lid
833-1 or 2
Assy selection
& cable terminations
Junction box / enclosure
833-5
Assy Selection
1-4-9-1
1 4 9-1 0B
LIGHTINGSERVICES
MAJOR / MINOR ROAD
CABLE LOOPING FROM LV PIT
10500-A4-1-4-9-1
5 83 8076 1
4927-A4-10.1,2,3 & 8B 10.01.13
F
Protection Cover
Polymeric Cable
VOLUME FOLDER ISSUEPAGE
Approved Ergon
Approved Energex
Checked
Drawn
Date
Date
Date
Date
A ORIGINAL ISSUE
HARD COPY UNCONTROLLED
C COPYRIGHT 2002 ENERGEX
ABN 50 087 646 062
Ergon Energy Corporation Limited
C COPYRIGHT 2002 ERGON ENERGY
ABN 40 078 849 055
ENERGEX Corporation Limited
ENERGEX or Ergon Energy
without written permission from
reproduced in part or whole
This document must not be
REFERENCE DRAWING ENERGEX
REFERENCE DRAWING ERGON
EE DRWG NO:
EGX DRWG NO:
C. Noel
F. Zaini
P. Relf / A. Bletchly
L. Burton / T. Borg
24/04/13
24/04/13
04/04/13
01/10/10
OVERHEAD CABLE
ENERGEX
CABLE TYPE S.C. NUMBER CABLE TYPE
ERGON ENERGY
REFERENCE NO.
CABLE TYPE
REFERENCE NO.
CABLE TYPES.C. NUMBERCABLE DESCRIPTION
ENERGEX
CABLE TYPE S.C. NUMBER CABLE TYPE
ERGON ENERGY
REFERENCE NO.
CABLE TYPE
REFERENCE NO.
CABLE TYPES.C. NUMBERCABLE DESCRIPTION
ENERGEX
CABLE TYPE S.C. NUMBER CABLE TYPE
ERGON ENERGY
REFERENCE NO.
CABLE TYPES.C. NUMBERCABLE DESCRIPTION
LV-6CUC2/507
2 x 25mm† ABC / XLPE
4 x 25mm† ABC / XLPE
2 x 6mm† Cu ABC / XLPE
225
425
-
-
507
1420045
1420051
1420068
614 1632489
1601
2406943
2400260
2400273
08727
07127
07231
LV 16mm† Cu 2 core PVC / PVC
LV 4mm† Cu 2 core PVC / PVC
LV 16mm† Cu 4 core XLPE / PVC LV-16CUC4/614
Note:
-
-
-
-
-
-
-
-
-4 core XLPE NJ/PVC
LV insect protected 16mm† Cu
LV-16CU2NS/1672
LV-4CU2NS/1671
LV-16CUC4/1601
1-4-10-1
1 4 10-1 0D
LIGHTINGSERVICES
SERVICE CABLE DETAILS
10500-A4-1-4-10-1
NIL
NIL
-
-
-
-
-
-
-
-
-
-
16153
16578
17119
REFERENCE NO.
CABLE TYPE
B 10.01.13
UNDERGROUND CABLE
UNDERGROUND CABLE
VOLUME FOLDER ISSUEPAGE
Approved Ergon
Approved Energex
Checked
Drawn
Date
Date
Date
Date
A ORIGINAL ISSUE
HARD COPY UNCONTROLLED
C COPYRIGHT 2002 ENERGEX
ABN 50 087 646 062
Ergon Energy Corporation Limited
C COPYRIGHT 2002 ERGON ENERGY
ABN 40 078 849 055
ENERGEX Corporation Limited
ENERGEX or Ergon Energy
without written permission from
reproduced in part or whole
This document must not be
REFERENCE DRAWING ENERGEX
REFERENCE DRAWING ERGON
EE DRWG NO:
EGX DRWG NO:
C. Noel
F. Zaini
P. Relf / A. Bletchly
L. Burton / T. Borg
19/04/17
19/04/17
01/04/17
01/10/10
C 06.01.14
1672
1671
neutral screen PVC NJ/PVC
LV insect protected 16mm† Cu
neutral screen PVC NJ/PVC
LV insect protected 4mm† Cu
-
-
-
-
D 22.11.16
4B25
LVC216 PVPV
LVC24 PVPV
LVC416 XPV
2. Energex conductor and cable codes are included in the Overhead Construction Manual and Underground Manual as applicable.
1. Ergon Energy cable codes are included in the Overhead Construction Manual & Underground Construction Manual as applicable.
PILLAR
600
FO
OTP
AT
H
KE
RB
SIGN
to suit local authority guidelines
pavement shall be reinstated
After installation the footpath /
NICK’S
ALL
NIGHT
TAVERNA
STAN ST
R300
tools only
excavation by hand
Caution live cables
3200
F
F
F
luminaire
non-standard
sign or other
illuminated
Customers
F
steel pole
Customers
supply
Energex
source of
indicating
Internal label
F
F
equipment
to suit customers
Pole foundation
F
earth electrode
Separate MEN F
TYPICAL NON-STANDARD LUMINAIRE DETAIL
street sign
Illuminated
F
breaker behind cover plate
service fuse and / or 10A circuit
Contractor to supply 16A HRC
CUSTOMERS SWITCHBOARD
F
Marker tape
F
Footpath
350600
F
F
Minimum cover in pavement
F
F
or flexible conduit
300mm min. radius bend F
responsibility.
equipment will be customer’s
cable from pillar to unmetered
with service fuse. Underground
install a service pillar complete
there is no pillar, Energex will
underground service where
If supply is required from an
ALTERNATIVELY
F
PLAN OF SERVICE
TYPICAL ROUTE
oncoming traffic.
side of pole from the
alignment and on opposite
at right angles to property
Customer’s cables installed
F
pole terminal panel 1-2-876
supply from existing public light
For supply other than pillar refer
if required
photo electric cell,
Energex approved
1-4-11-2
1 4 11-2 0B
LIGHTINGSERVICES - ENERGEX ONLY
TYPICAL UNMETERED UNDERGROUND SUPPLY
FOR NON STANDARD LUMINAIRE
10500-A4-1-4-11-2
NIL
4927-A4-2.26B 10.12.12
run customer’s mains from pillar
Energex approved contractor to
SERVICE PILLAR EXISTING
by the customers contractor)
Cu 2c PVC/PVC cable in heavy duty (orange) 40mm conduit (supplied and installed
CUSTOMERS MAINS
VOLUME FOLDER ISSUEPAGE
Approved Ergon
Approved Energex
Checked
Drawn
Date
Date
Date
Date
A ORIGINAL ISSUE
HARD COPY UNCONTROLLED
C COPYRIGHT 2002 ENERGEX
ABN 50 087 646 062
Ergon Energy Corporation Limited
C COPYRIGHT 2002 ERGON ENERGY
ABN 40 078 849 055
ENERGEX Corporation Limited
ENERGEX or Ergon Energy
without written permission from
reproduced in part or whole
This document must not be
REFERENCE DRAWING ENERGEX
REFERENCE DRAWING ERGON
EE DRWG NO:
EGX DRWG NO:
C. Noel
F. Zaini
P. Relf / A. Bletchly
L. Burton / T. Borg
24/04/13
24/04/13
04/04/13
01/10/10
VOLUME FOLDER ISSUEPAGE
A
HARD COPY UNCONTROLLED
C COPYRIGHT 2002 ENERGEX
Ergon Energy Corporation Limited
ABN 50 087 646 062
C COPYRIGHT 2002 ERGON ENERGY
ENERGEX Corporation Limited
ABN 40 078 849 055This document must not be
reproduced in part or whole
without written permission from
ENERGEX or Ergon Energy
EE DRWG NO:
EGX DRWG NO:
J. Brooks
R. English
D. Taylor / B. Oyegoke
L. Burton / T. Borg
14/10/10
14/10/10
14/10/10
01/10/10
1-4-12-1
1 4 12-1 0A
LIGHTINGSERVICES - ENERGEX ONLY
MAJOR & MINOR ROAD BIG POLE
U/G SUPPLY TYPICAL INSTALLATION
10500-A4-1-4-12-1
NIL
4927-A4-10.1
180 07112 AR
216
75
0 m
in
75 min
1. For footing details of poles refer
Public Lighting Construction Manual.
279
275 or276
279 (Note 1)
180
Road
Footp
ath
Outreach
2. Supply for poles can be from a Pit or Pillar.
(Note 3)
242
192or182
QTYDESCRIPTIONPART S.C.
288and287
3. Refer to Underground Construction Manual.
for conduits - foothpath & roadway.
1200 m
in
Ro
ad
way
Majo
r/A
teri
al
Rd. (D
MR
Contr
ol)
Min
or
Road
500 R
oadw
ay
60
0 m
in
(Note 2)
NOTES :
182 07127 AR
192 08727 AR
216 14318 AR
242 13538 AR
275 06514 AR
276 17030 AR
279 06640 AR
287 17122 AR
288 17121 AR
Cable, 2.5mm† 2c Flat PVC/PVC
Cable, 4.0mm† 2c Flat PVC/PVC
Cable, 16mm† 2c Flat PVC/PVC
Tape, U/G Marking, Orange 150mm
Conduit, 50mm ID Flexible, Orange
Bend, Conduit, UPVC 40mm x 300mm
Bend, Conduit, UPVC 40mm x 600mm
Conduit, 40mm Rigid UPVC, Orange
Adaptor, 40mm Rigid / 40mm Flexible
Conduit 40mm Flexible, Orange
PART DESCRIPTION S.C. QTY
Terminal ChamberDoor
NORMAL ORIENTATION OF POLEPLAN VIEW
Under
R’w
ay
C
rossin
g
Footp
ath
350 F
ootp
ath
To TerminalPanel
Pole DetailsTypical Only
Major Road - BIG Section 1-5
Minor Road - BIG Section 1-6
180 07112 AR
2161. For footing details of poles refer
Public Lighting Construction Manual.
279
275 or276
279
180
2. Supply for poles can be from a Pit or Pillar.
242
192or182
QTYDESCRIPTIONPART S.C.
288and287
3. Refer to Underground Construction Manual.
for conduits - foothpath & roadway.
12
00
min
Ro
ad
way
Min
or
Road
NOTES :
182 07127 AR
192 08727 AR
216 14318 AR
242 13538 AR
275 06514 AR
276 17030 AR
279 06640 AR
287 17122 AR
288 17121 AR
Cable, 2.5mm† 2c Flat PVC/PVC
Cable, 4.0mm† 2c Flat PVC/PVC
Cable, 16mm† 2c Flat PVC/PVC
Tape, U/G Marking, Orange 150mm
Conduit, 50mm ID Flexible, Orange
Bend, Conduit, UPVC 40mm x 300mm
Bend, Conduit, UPVC 40mm x 600mm
Conduit, 40mm Rigid UPVC, Orange
Adaptor, 40mm Rigid / 40mm Flexible
Conduit 40mm Flexible, Orange
PART DESCRIPTION S.C. QTY
To TerminalPanel
Pole DetailsTypical Only
VOLUME FOLDER ISSUEPAGE
A
HARD COPY UNCONTROLLED
C COPYRIGHT 2002 ENERGEX
Ergon Energy Corporation Limited
ABN 50 087 646 062
C COPYRIGHT 2002 ERGON ENERGY
ENERGEX Corporation Limited
ABN 40 078 849 055This document must not be
reproduced in part or whole
without written permission from
ENERGEX or Ergon Energy
EE DRWG NO:
EGX DRWG NO:
J. Brooks
R. English
D. Taylor / B. Oyegoke
L. Burton / T. Borg
14/10/10
14/10/10
14/10/10
01/10/10
1-4-12-2
1 4 12-2 0A
LIGHTINGSERVICES - ENERGEX ONLY
MAJOR & MINOR ROAD BPM POLE
U/G SUPPLY TYPICAL INSTALLATION
10500-A4-1-4-12-2
NIL
4927-A4-10.2
Majo
r -
Ate
rial
Road
75
0 m
in
60
0 m
in
Footp
ath
Under
Road
Cro
ssin
gBottom Of Trench
Ro
ad
way
Footp
ath
30
0
50
0
Note 2
Note 1
Ground Level
Note 2
TYPICAL U/G SUPPLY ARRANGEMENT
(for roadway crossing refer specificaton URD)
Major Road - BPM/SBM Section 1-5
Minor Road - BPM Section 1-6
MATERIAL
ASSY DESCRIPTION QTY
1875-1
801-1
VOLUME FOLDER ISSUEPAGE
A
HARD COPY UNCONTROLLED
C COPYRIGHT 2002 ENERGEX
Ergon Energy Corporation Limited
ABN 50 087 646 062
C COPYRIGHT 2002 ERGON ENERGY
ENERGEX Corporation Limited
ABN 40 078 849 055This document must not be
reproduced in part or whole
without written permission from
ENERGEX or Ergon Energy
EE DRWG NO:
EGX DRWG NO:
J. Brooks
R. English
D. Taylor / B. Oyegoke
L. Burton / T. Borg
14/10/10
14/10/10
14/10/10
14/10/10
1-4-15-1
1 4 15-1 0A
LIGHTINGSERVICES
MAJOR / MINOR ROAD
STREETLIGHT SERVICE FROM PILLAR
10500-A4-1-4-15-1
NIL
4927-A4-10.8
SL32A label for service fuse
Cartridge fuse link 32A HRC
Assy 801-1
60
0
125
SL
PILLAR
Pro
pert
y A
lig
nm
en
t
Nom
32A
Min
Consumers
Mains
To
Earth
Rod
Assy 875-1
NOTES :
5. An M.E.N earth is to be installed at the pole.
communication assets.
minimum separation requirements between metal cable guard and
4. Refer Earthing section of the Overhead Construction Manual for
- where there is a high likelihood of impact
- where metal bladed brush cutter may be used
- subject to grass fire
3. Polymeric cable guard is not to be used in areas:
2. Do not obstruct climbing access.
1. Locate cable on opposite side of pole to oncoming traffic where possible.
MATERIAL
ASSY
804-1
804-6
804-7
DESCRIPTION QTY
2
Connector I.P.C 25/95mm† main to 6/35mm† tap
Connector tap-off bare aluminium main
Connector tap-off bare copper main
802-6
803-1
Fuse holder 100A (service) to bracket
801-1
801-6
909-1
909-7
910-1
910-5
Cartridge fuse link 32A HRC 1
1
1
1
Bracket (service fuse) to wood pole
Saddle (20mm) to wood pole
Guard polymeric (small) to wood pole
Guard metal (100) to wood pole1
1
1
Termination 16mm† N/S cable
1-4-16-1
1 4 16-1 0A
LIGHTINGSERVICES - ERGON ONLY
UNDERGROUND FROM OVERHEAD SYSTEM
NOTES AND MATERIAL
10500-A4-1-4-16-1
NIL
NIL
Bridging cable 25mm† LVABC transformer
VOLUME FOLDER ISSUEPAGE
Approved Ergon
Approved Energex
Checked
Drawn
Date
Date
Date
Date
A ORIGINAL ISSUE
HARD COPY UNCONTROLLED
C COPYRIGHT 2002 ENERGEX
ABN 50 087 646 062
Ergon Energy Corporation Limited
C COPYRIGHT 2002 ERGON ENERGY
ABN 40 078 849 055
ENERGEX Corporation Limited
ENERGEX or Ergon Energy
without written permission from
reproduced in part or whole
This document must not be
REFERENCE DRAWING ENERGEX
REFERENCE DRAWING ERGON
EE DRWG NO:
EGX DRWG NO:
C. Noel
F. Zaini
P. Relf / A. Bletchly
L. Burton / T. Borg
19/04/17
19/04/17
01/04/17
19/12/16
G.L.
or 804-7
Assy 804-1 or 804-6
F
F
Assy 910-5
Active
Assy 802-6
Assy 801-6 & 801-1
Assy 910-1
(300mm intervals)
Assy 803-1
F
F 2400 min
F
F
F
F
F
or 901-7
Assy 901-1
Max
150
Min
2400
Min
100
F
F
F
Cable support
(Refer note 3)
909-1 or 909-7
Assy Selection
Ground Line
Wood Pole
F
earthing details.
EARTHING for pole and cable guard
Refer Overhead Construction Manual
Metal cable guard shall be earthed.
1-4-16-2
1 4 16-2 0A
LIGHTINGSERVICES - ERGON ONLY
UNDERGROUND FROM OVERHEAD SYSTEM
CONSTRUCTION
10500-A4-1-4-16-2
NIL
NIL
Construction Type
SPTSL
VOLUME FOLDER ISSUEPAGE
Approved Ergon
Approved Energex
Checked
Drawn
Date
Date
Date
Date
A ORIGINAL ISSUE
HARD COPY UNCONTROLLED
C COPYRIGHT 2002 ENERGEX
ABN 50 087 646 062
Ergon Energy Corporation Limited
C COPYRIGHT 2002 ERGON ENERGY
ABN 40 078 849 055
ENERGEX Corporation Limited
ENERGEX or Ergon Energy
without written permission from
reproduced in part or whole
This document must not be
REFERENCE DRAWING ENERGEX
REFERENCE DRAWING ERGON
EE DRWG NO:
EGX DRWG NO:
C. Noel
F. Zaini
P. Relf / A. Bletchly
L. Burton / T. Borg
19/04/17
19/04/17
01/04/17
19/12/16