LoRaWAN™IP68 PULSE READER
UM3080
LoRaWAN™ IP68 pulse reader, enables acquisition of data
from the pulse emitting devices and transmits it wirelessly to
the LoRaWAN™ network.
LoRaWAN™ IP68 pulse reader is meant to be connected
to the existing devices’ pulse output. It is powered by a
long-life battery.
FW >= 0.7.0
2 LoRaWAN™ IP68 PULSE READER UM3080
OVERVIEW
EfficientLoRaWAN™ IP68 Pulse Reader has a bidirectional, battery powered, long-range transceiver with low power consumption.
IntelligentReal-time usage data is gathered wirelessly and processed automatically. Data is accessible from your LoRaWAN™ provider.
Pulse meteringFrequent reporting provides a detailed usage overview. Can be used with any pulse emitting device (water, electricity, gas meter, etc.).
Usage detectionLoRaWAN™ Outdoor Pulse Reader can be configured to trigger mode to send alerts when usage is detected.
APPLICATIONS
• Long range wireless data transmission• Pulse counting• Pre-installed long-life battery• Built-in antenna• DIN rail mount• Trigger mode
FEATURES
* Lifetime depends from the device location and reporting interval.
• Configurable reporting interval• Maintenance free - install & forget• Easy installation• Average life 8 years*• Secure communication
3 LoRaWAN™ IP68 PULSE READER UM3080
SPECIFICATIONS
Length: 109 mm
Height: 27 mm
Width: 27 mm
Weight: 72 g
Cable length: 1 m
Operating temperature: -20°C ... +65°C
Communication range: up to 15 km*
Tx power: up to +20 dBm
Rx Sensitivity: -142 dBm
MAC Layer: LoRaWAN™
Physical Layer: LoRa®
Connector: Pigtail
Body material: PA6
IP Rating: IP68
Communication: LoRaWAN™
* Communication range is dependent on the location of the sensor and nearest base station.
INPUT SPECIFICATIONSDigital Max Frequency: 15 Hz
(Dry contact) Pulled internali to: 3 V
(Active contact) Max voltage: 6 V
4 LoRaWAN™ IP68 PULSE READER UM3080
PORT LIST
fPort Usage Transmission Page
24 Status ⇈ 5
25 Usage ⇈ 10
49 Config request ⇅ 15
50 Configuration ⇊ 23
51 Update mode ⇊ 31
99 Boot/Debug ⇈ 32
For FW version >= 0.7.0
COMMUNICATION
Bit order: LSB
Usage reporting: Unconfirmed messages
Status reporting: Confirmed messages
5 LoRaWAN™ IP68 PULSE READER UM3080
Byte 0 Byte 1 Byte 2 Byte 3 Byte 4 Byte .. Byte n
Inteface map Battery Temp RSSI Interface status blocks
uint8(mapped)*
int8(°C)
int8(dBm) Described below
fPort 24 Status Message
Bit # Parameter Value
0 Digital 10 - not sent
1 - sent1 Digital 2
2 RFU
3 RFU
4 RFU
5 RFU
6 User triggered 0 - false1 - true
7 RFU
Digital interface status block
r Byte 0 r Byte 1 r Byte 2 r Byte 3 r Byte 4
Settings Counter
uint32
Bit # Parameter Value
0 Value during reporting 0 - low1 - high
1 Trigger mode 0 - disabled1 - enabled
2 Trigger alert 0 - no1 - alert
3 RFU
4
Medium type
5
6
7
Value Parameter
00 n/a
01 Pulses
02 Water in L
03 Electricity in Wh
04 Gas in L
05 Heat in Wh
.. RFU
0F RFU
Interface values are reported according to the intercace map in the order defined in the interface map
* depends from the battery type. (reported in boot message)
Status message can be triggered with 1 second magnet switch (same place as activating). The time between two consecutive packets is dependent of the duty cycle. If the message is triggered too often, it will go to lockdown for 1 hour. It will still be working as meant to, but will not send any data.
6 LoRaWAN™ IP68 PULSE READER UM3080
Message sample
Message in base64 A/YaSxIBAAAAEMQJAAA=
Message decoded to HEX 03F61A4B120100000010C4090000
Interface map HEX message 0x03
Interface map HEX message converted to binary 0b00000011
Binary converted to statuses (LSB) 1 : Digital 1 - sent
1 : Digital 2 - sent
0 : RFU
0 : RFU
0 : RFU
0 : RFU
0 : User triggered - no
0 : RFU
Sensor Battery HEX message 0xF6
HEX message converted to decimal 246
Decimal value mapped to voltage 3.646 (V)
Sensor Tempertaure HEX message 0x1A
HEX message converted to signed decimal 26 (°C)
Sensor RSSI HEX message 0x4B
HEX message converted to decimal 75
Decimal value multiplied by -1 -75 (dBm)
7 LoRaWAN™ IP68 PULSE READER UM3080
Digital 1 settings HEX message 0x12
Interface map HEX message converted to binary 0b00010010
Binary converted to statuses (LSB) 0 : Value during reporting - 0
1 : Trigger mode - true
0 : Alert - no
0 : RFU - n/a
1 : Medium type [0b0001]
0 :
0 :
0 :
Medium type binary value converted to HEX 0x01
HEX message converted to medium Pulses
Counter 0x01000000 HEX message flip for MSB 0x00000001
HEX message converted to decimal 1 (Pulse/Trigger)
Digital 2 settings HEX message 0x10
Interface map HEX message converted to binary 0b00010000
Binary converted to statuses (LSB) 0 : Value during reporting - 0
0 : Trigger mode - false
0 : Alert - no
0 : RFU - n/a
1 : Medium type [0b0001]
0 :
0 :
0 :
Medium type binary value converted to HEX 0x01
HEX message converted to medium Pulses
8 LoRaWAN™ IP68 PULSE READER UM3080
Counter 0xC4090000 HEX message flip for MSB 0x000009C4
HEX message converted to decimal 2500 (Pulses)
9 LoRaWAN™ IP68 PULSE READER UM3080
fPort 25 Usage MessageByte 0 Byte 1 Byte .. Byte n
Settings Interface usage blocks
Described below
Bit # Parameter Value
0 Digital 10 - not sent
1 - sent1 Digital 2
2 RFU
3 RFU
4 RFU
5 RFU
6 RFU
7 RFU
Digital interface usage block
r Byte 0 r Byte 1 r Byte 2 r Byte 3 r Byte 4
Settings Counter
uint32
Bit # Parameter Value
0 Value during reporting 0 - low1 - high
1 Trigger mode 0 - disabled1 - enabled
2 RFU
3 RFU
4
Medium type
5
6
7
Value Parameter
00 n/a
01 Pulses
02 Water in L
03 Electricity in Wh
04 Gas in L
05 Heat in Wh
.. RFU
0F RFU
Interface values are reported according to the intercace map in the order defined in the interface map
10 LoRaWAN™ IP68 PULSE READER UM3080
Message sample
Message in base64 AxIBAAAAEAAAAAA=
Message decoded to HEX 0312010000001000000000
Interface map HEX message 0x03
Interface map HEX message converted to binary 0b00000011
Binary converted to statuses (LSB) 1 : Digital 1 - sent
1 : Digital 2 - sent
0 : RFU
0 : RFU
0 : RFU
0 : RFU
0 : RFU
0 : RFU
Digital 1 settings HEX message 12
Interface map HEX message converted to binary 0b00010010
Binary converted to statuses (LSB) 0 : Value during reporting - 0
1 : Trigger mode - true
0 : Alert - no
0 : RFU - n/a
1 : Medium type [0b0001]
0 :
0 :
0 :
Medium type binary value converted to HEX 0x01
HEX message converted to medium Pulses
Counter 0x01000000 HEX message flip for MSB 0x00000001
HEX message converted to decimal 1 (Pulse/Trigger)
11 LoRaWAN™ IP68 PULSE READER UM3080
Digital 2 settings HEX message 0x10
Interface map HEX message converted to binary 0b00010000
Binary converted to statuses (LSB) 0 : Value during reporting - 0
0 : Trigger mode - false
0 : Alert - no
0 : RFU - n/a
1 : Medium type [0b0001]
0 :
0 :
0 :
Medium type binary value converted to HEX 0x01
HEX message converted to medium Pulses
Counter 0x00000000 HEX message flip for MSB 0x00000000
HEX message converted to decimal 0 (Pulses)
12 LoRaWAN™ IP68 PULSE READER UM3080
fPort 49 Configuration Request Message
Byte 0 Operation
00 General config request
Message sample
Message goal: Request device configuration
Header Select Header HEX code 0x00
Compile message for sending (HEX) 0x00
Control value in base64 to control after sending AA==
13 LoRaWAN™ IP68 PULSE READER UM3080
Response
Sent to fPort 49 in the following format
Byte 0 Byte 1 Byte 2 Byte 3 Byte 4 Byte 5 Byte 6 Byte n
Header Usage interval Status interval Config. map Interface map Interface config blocks
00 uint16 (min) uint16 (min) Described below
Bit # Parameter Value
0 Digital 10 - disabled1 - enabled
1 Digital 2
2 RFU
3 RFU
4 RFU
5 RFU
6 RFU
7 RFU
General configuration
Bit # Parameter Value
0 usage sent 0 - if new data1 - always
1 RFU
2 RFU
3 RFU
4 RFU
5 RFU
6 RFU
7 RFU
14 LoRaWAN™ IP68 PULSE READER UM3080
r Byte 0 r Byte 1 r Byte 2 r Byte 3 r Byte 4 r Byte 5
Configuration Mode Multiplier
Float IEEE 754*
Bit # Parameter Value
0 Interface enabled 1 - enabled
1 Mode 1 - sent
2 Multiplier 0 - not sent1 - sent
3 RFU
4
Medium type5
6
7
Value Parameter
00 n/a
01 Pulses
02 Water in L
03 Electricity in Wh
04 Gas in L
05 Heat in Wh
.. RFU
0F RFU
Bit # Parameter Value
0 Trigger mode0 - disabled1 - enabled
1 RFU
2 RFU
3 RFU
4 RFU
5 RFU
6
Trigger lenght
7
Value Parameter
00 1 sec
01 10 sec
02 1 min
03 1 h
Digital interface configuration block
15 LoRaWAN™ IP68 PULSE READER UM3080
Message sample
Message in base64 ADwAPAABAwMBEwA=
Message decoded to HEX 003C003C00010303011300
Header 00 decoded Response for general configuration request
Usage interval 0x3C00 HEX message flip for MSB 0x003C
HEX message converted to decimal 60 (Minutes)
Status interval 0x3C00 HEX message flip for MSB 0x003C
HEX message converted to decimal 60 (Minutes)
Configuration map HEX message 0x01
Interface map HEX message converted to binary 0b00000001
Binary converted to configuration (LSB) 1 : Usage sent - always
0 : RFU - n/a
0 : RFU - n/a
0 : RFU - n/a
0 : RFU - n/a
0 : RFU - n/a
0 : RFU - n/a
0 : RFU - n/a
Interface map HEX message 0x03
Interface map HEX message converted to binary 0b00000011
Binary converted to statuses (LSB) 1 : Digital 1 - enabled
1 : Digital 2 - enabled
0 : RFU
0 : RFU
0 : RFU
0 : RFU
0 : RFU
0 : RFU
16 LoRaWAN™ IP68 PULSE READER UM3080
Digital 1 configuration map HEX message 0x03
Configuration map HEX message converted to binary 0b00000011
Binary converted to configuration (LSB) 1 : Interface - enabled
1 : Mode - sent
0 : Multiplier - not sent
0 : RFU
0 : Medium type - [0b0000]
0 :
0 :
0 :
Medium type binary value converted to HEX 0x00
HEX message converted to type n/a
Digital 1 mode HEX message 0x01
Mode HEX message converted to binary 0b00000001
Binary converted to configuration (LSB) 1 : Trigger mode - enabled
0 : RFU
0 : RFU
0 : RFU
0 : RFU
0 : RFU
0 : Trigger length - [0b00]
0 :
Trigger length binary value converted to HEX 0x00
HEX message converted to length 1 (second)
17 LoRaWAN™ IP68 PULSE READER UM3080
Digital 2 configuration map HEX message 0x13
Configuration map HEX message converted to binary 0b00010011
Binary converted to configuration (LSB) 1 : Interface - enabled
1 : Mode - sent
0 : Multiplier - not sent
0 : RFU
1 : Medium type - [0b0001]
0 :
0 :
0 :
Medium type binary value converted to HEX 0x01
HEX message converted to type pulses
Digital 1 mode HEX message 0x00
Mode HEX message converted to binary 0b00000000
Binary converted to configuration (LSB) 0 : Trigger mode - disabled
0 : RFU
0 : RFU
0 : RFU
0 : RFU
0 : RFU
0 : Trigger length - [0b00]
0 :
Trigger length binary value converted to HEX 0x00
HEX message converted to length 1 (second)
18 LoRaWAN™ IP68 PULSE READER UM3080
Byte0 Byte ... Byte n
Header Payload
fPort 50 Configuration Message
Different headers with their respective payloads are described below
General configuration
Byte 0 Byte 1 Byte 2 Byte 3 Byte 4 Byte 5 Byte 6
Header Configuration Usage interval Status interval Usage config.
0x00 uint16(min)
uint16(min)
Bit # Function Value
0 Usage interval
0 - not sent1 - sent1 Status interval
2 Usage config.
3 RFU
4 RFU
5 RFU
6 RFU
7 RFU
Bit # Function Value
0 Usage without new data
0 - not sent1 - sent
1 RFU
2 RFU
3 RFU
4 RFU
5 RFU
6 RFU
7 RFU
19 LoRaWAN™ IP68 PULSE READER UM3080
Message sample
Message goal: Set usage reporting to 2 hour and to be sent even without new data.
Header Select Header HEX code 0x00
Configuration Configuration selection 1 : Usage interval - sent
0 : Status interval - not sent
1 : Usage configuration - sent
0 : RFU
0 : RFU
0 : RFU
0 : RFU
0 : RFU
Selection converted to binary 0b00000101
Selection converted to HEX 0x05
Usage reporting interval Convert interval 120 to HEX 0x78
Flip HEX value to LSB 0x7800
Usage configuration selection 1 : send usage - always
0 : RFU
0 : RFU
0 : RFU
0 : RFU
0 : RFU
0 : RFU
0 : RFU
Selection converted to binary 0b00000001
Selection converted to HEX 0x01
20 LoRaWAN™ IP68 PULSE READER UM3080
Compile message for sending (HEX) 0005780001
Control value in base64 to control after sending AAV4AAE=
21 LoRaWAN™ IP68 PULSE READER UM3080
Interface configuration
Byte 0 Byte 1 Byte 2 Byte .. Byte n
Header Settings Interface configuration blocks
0x01 Described below
Bit # Parameter Value
0 Digital 1 reporting0 - not sent
1 - configured1 Digital 2 reporting
2 RFU
3 RFU
4 RFU
5 RFU
6 RFU
7 RFU
22 LoRaWAN™ IP68 PULSE READER UM3080
Digital interface configuration block
r Byte 0 r Byte 1 r Byte 2 r Byte 3 r Byte 4 r Byte 5 r Byte 6 r Byte 7 r Byte 8 r Byte 9
Configuration Mode Multiplier** True reading
Float IEEE 754(pulses in unit)
uint32(units)
Bit # Parameter Value
0 Interface enable*** 0 - disable 1 - enable
1 Mode
0 - not sent1 - configured2 Multiplier
3 True reading
4
Medium type****5
6
7
Value Parameter
00 n/a
01 Pulses
02 Water in L
03 Electricity in Wh
04 Gas in L
05 Heat in Wh
.. RFU
0F RFU
Bit # Parameter Value
0 Trigger mode0 - disabled1 - enabled
1 RFU
2 RFU
3 RFU
4 RFU
5 RFU
6
Trigger lenght*
7
Value Parameter
00 1 sec
01 10 sec
02 1 min
03 1 h
* Configured together with Trigger mode. Otherwise must be 00** Multiplier is sent together with Unit type and True reading. In trigger mode Unit type is invalid and entire packet is discarded. *** Disabled interface can not have any other configuration**** Configured together with Muiltiplier. Otherwise must be 00
23 LoRaWAN™ IP68 PULSE READER UM3080
Message sample
Message goal: Configure Digital interface 1 to trigger mode. Set trigger length to 1 minute
Header Select Header HEX code 0x01
Configuration Interface selection 1 : Digital 1 - sent
0 : Digital 2 - not sent
0 : RFU
0 : RFU
0 : RFU
0 : RFU
0 : RFU
0 : RFU
Selection converted to binary 0b00000001
Selection converted to HEX 0x01
Digital 1 parameter configuration selection 1 : Interface - enable
1 : Mode - sent
0 : Multiplier - not sent
0 : True reading - not sent
x : Medium type
x :
x :
x :
Medium type n/a HEX value 0x00
HEX message converted to binary 0b0000
Whole binary message assembled 0b00000011
Binary value converted to HEX 0x03
24 LoRaWAN™ IP68 PULSE READER UM3080
Digital 1 mode configuration selection 1 : Trigger mode - enable
1 : Mode - sent
0 : RFU
0 : RFU
0 : RFU
0 : RFU
x : Trigger length
x :
Trigger length 1 minute HEX value 0x02
HEX message converted to binary 0b10
Whole binary message assembled 0b10000011
Binary value converted to HEX 0x83 Compile message for sending (HEX) 01010381
Control value in base64 to control after sending AQEDgQ==
25 LoRaWAN™ IP68 PULSE READER UM3080
fPort 51 Update message
Byte 0
Header
FF
Activate update mode for BT update for 2 minutes. if nothing is done the device will reboot, join and resume working
NB! Only unconfirmed messages should be used for this message.
Message sample
Message goal: Set device to update modeHeader Select Header HEX code FF Compile message for sending (HEX) FF
Control value in base64 to control after sending /w==
26 LoRaWAN™ IP68 PULSE READER UM3080
fPort 99 Boot/Debug Messages
Byte 0 Byte 1 Byte 2 Byte 3 Byte 4 Byte 5 Byte 6 Byte 7 Byte 8 Byte 8
0x00Boot
Serial (HEX)
Firmware(HEX)
Reset reason(HEX)
Battery info(HEX)
Boot message
Value Voltage
0x01 3V
0x02 3.6V
Byte 0 Byte 1 Byte 2 Byte .. Byte n
0x01Shutdown
Reason (HEX) Regular tatus message
Shutdown message
Value Voltage
0x20 Hardware error
0x31 Shutdown by user (magnet)
0x32 Shutdown by user (DFU)
Value Reason
0x02 Watchdog reset
0x04 Soft reset (e.g DFU mode)
0x10 Normal startup by magnet
27 LoRaWAN™ IP68 PULSE READER UM3080
Message sample
Message in base64 AMcBFkwABwgQAg==
Message decoded to hex 00C701164C0007081002
Header 0x00 decoded Boot message
Device serial 0xC701164C HEX message flip for MSB 0x4C1601C7
Firmware version Major version in HEX 0x00
HEX value converted to decimal 0 Minor version in HEX 0x07
HEX value converted to decimal 7 Patch version in HEX 0x08
HEX value converted to decimal 8 Reset reason 10 HEX message HEX message converted to reason Normal startup by magnet
Battery info 02 HEX message HEX message converted to voltage 3.6 (V)
28 LoRaWAN™ IP68 PULSE READER UM3080
255 - Not measured
254 - 4253 - 3,95252 - 3,9251 - 3,85250 - 3,8249 - 3,75248 - 3,7247 - 3,65246 - 3,646245 - 3,642244 - 3,638243 - 3,634242 - 3,63241 - 3,626240 - 3,622239 - 3,618238 - 3,614237 - 3,61236 - 3,606235 - 3,602236 - 3,606235 - 3,602234 - 3,598233 - 3,594232 - 3,59231 - 3,586230 - 3,582229 - 3,578228 - 3,574227 - 3,57226 - 3,566225 - 3,562224 - 3,558223 - 3,554222 - 3,55221 - 3,546220 - 3,542219 - 3,538218 - 3,534217 - 3,53216 - 3,526215 - 3,522214 - 3,518213 - 3,514212 - 3,51211 - 3,506210 - 3,502209 - 3,498208 - 3,494207 - 3,49
206 - 3,486205 - 3,482204 - 3,478203 - 3,474202 - 3,47201 - 3,466200 - 3,462199 - 3,458198 - 3,454197 - 3,45196 - 3,446195 - 3,442194 - 3,438193 - 3,434192 - 3,43191 - 3,426190 - 3,422189 - 3,418188 - 3,414187 - 3,41186 - 3,406185 - 3,402184 - 3,398183 - 3,394182 - 3,39181 - 3,386180 - 3,382179 - 3,378178 - 3,374177 - 3,37176 - 3,366175 - 3,362174 - 3,358173 - 3,354172 - 3,35171 - 3,346170 - 3,342169 - 3,338168 - 3,334167 - 3,33166 - 3,326165 - 3,322164 - 3,318163 - 3,314162 - 3,31161 - 3,306160 - 3,302159 - 3,298158 - 3,294157 - 3,29156 - 3,286155 - 3,282
154 - 3,278153 - 3,274152 - 3,27151 - 3,266150 - 3,262149 - 3,258148 - 3,254147 - 3,25146 - 3,246145 - 3,242144 - 3,238143 - 3,234142 - 3,23141 - 3,226140 - 3,222139 - 3,218138 - 3,214137 - 3,21136 - 3,206135 - 3,202134 - 3,198133 - 3,194132 - 3,19131 - 3,186130 - 3,182129 - 3,178128 - 3,174127 - 3,17126 - 3,166125 - 3,162124 - 3,158123 - 3,154122 - 3,15121 - 3,146120 - 3,142119 - 3,138118 - 3,134117 - 3,13116 - 3,126115 - 3,122114 - 3,118113 - 3,114112 - 3,11111 - 3,106110 - 3,102109 - 3,098108 - 3,094107 - 3,09106 - 3,086105 - 3,082104 - 3,078103 - 3,074
102 - 3,07101 - 3,066100 - 3,06299 - 3,05898 - 3,05497 - 3,0596 - 3,04695 - 3,04294 - 3,03893 - 3,03492 - 3,0391 - 3,02690 - 3,02289 - 3,01888 - 3,01487 - 3,0186 - 3,00685 - 3,00284 - 2,99883 - 2,99482 - 2,9981 - 2,98680 - 2,98279 - 2,97878 - 2,97477 - 2,9776 - 2,96675 - 2,96274 - 2,95873 - 2,95472 - 2,9571 - 2,94670 - 2,94269 - 2,93868 - 2,93467 - 2,9366 - 2,92665 - 2,92264 - 2,91863 - 2,91462 - 2,9161 - 2,90660 - 2,90259 - 2,89858 - 2,89457 - 2,8956 - 2,88655 - 2,88254 - 2,87853 - 2,87452 - 2,8751 - 2,866
50 - 2,86249 - 2,85848 - 2,85447 - 2,8546 - 2,84645 - 2,84244 - 2,83843 - 2,83442 - 2,8341 - 2,82640 - 2,82239 - 2,81838 - 2,81437 - 2,8136 - 2,80635 - 2,80234 - 2,79833 - 2,79432 - 2,7931 - 2,78630 - 2,78229 - 2,77828 - 2,77427 - 2,7726 - 2,76625 - 2,76224 - 2,75823 - 2,75422 - 2,7521 - 2,74620 - 2,74219 - 2,73818 - 2,73417 - 2,68416 - 2,63415 - 2,58414 - 2,53413 - 2,48412 - 2,43411 - 2,38410 - 2,3349 - 2,2848 - 2,2347 - 2,1846 - 2,1345 - 2,0844 - 2,0343 - 1,9842 - 1,9341 - 1,884
0 - N/A
3.6V BATTERY OFFSET CHART
29 LoRaWAN™ IP68 PULSE READER UM3080
255 - Not measured
254 - 3,6253 - 3,55252 - 3,5251 - 3,45250 - 3,4249 - 3,35248 - 3,3247 - 3,25246 - 3,2245 - 3,15244 - 3,146243 - 3,142242 - 3,138241 - 3,134240 - 3,13239 - 3,126238 - 3,122237 - 3,118236 - 3,114235 - 3,11234 - 3,106233 - 3,102232 - 3,098231 - 3,094230 - 3,09229 - 3,086228 - 3,082227 - 3,078226 - 3,074225 - 3,07224 - 3,066223 - 3,062222 - 3,058221 - 3,054220 - 3,05219 - 3,046218 - 3,042217 - 3,038216 - 3,034215 - 3,03214 - 3,026213 - 3,022212 - 3,018211 - 3,014210 - 3,01209 - 3,006208 - 3,002207 - 2,998206 - 2,994205 - 2,99
204 - 2,986203 - 2,982202 - 2,978201 - 2,974200 - 2,97199 - 2,966198 - 2,962197 - 2,958196 - 2,954195 - 2,95194 - 2,946193 - 2,942192 - 2,938191 - 2,934190 - 2,93189 - 2,926188 - 2,922187 - 2,918186 - 2,914185 - 2,91184 - 2,906183 - 2,902182 - 2,898181 - 2,894180 - 2,89179 - 2,886178 - 2,882177 - 2,878176 - 2,874175 - 2,87174 - 2,866173 - 2,862172 - 2,858171 - 2,854170 - 2,85169 - 2,846168 - 2,842167 - 2,838166 - 2,834165 - 2,83164 - 2,826163 - 2,822162 - 2,818161 - 2,814160 - 2,81159 - 2,806158 - 2,802157 - 2,798156 - 2,794155 - 2,79154 - 2,786153 - 2,782
152 - 2,778151 - 2,774150 - 2,77149 - 2,766148 - 2,762147 - 2,758146 - 2,754145 - 2,75144 - 2,746143 - 2,742142 - 2,738141 - 2,734140 - 2,73139 - 2,726138 - 2,722137 - 2,718136 - 2,714135 - 2,71134 - 2,706133 - 2,702132 - 2,698131 - 2,694130 - 2,69129 - 2,686128 - 2,682127 - 2,678126 - 2,674125 - 2,67124 - 2,666123 - 2,662122 - 2,658121 - 2,654120 - 2,65119 - 2,646118 - 2,642117 - 2,638116 - 2,634115 - 2,63114 - 2,626113 - 2,622112 - 2,618111 - 2,614110 - 2,61109 - 2,60608 - 2,602107 - 2,598106 - 2,594105 - 2,59104 - 2,586103 - 2,582102 - 2,578101 - 2,574
100 - 2,5799 - 2,56698 - 2,56297 - 2,55896 - 2,55495 - 2,5594 - 2,54693 - 2,54292 - 2,53891 - 2,53490 - 2,5389 - 2,52688 - 2,52287 - 2,51886 - 2,51485 - 2,5184 - 2,50683 - 2,50282 - 2,49881 - 2,49480 - 2,4979 - 2,48678 - 2,48277 - 2,47876 - 2,47475 - 2,4774 - 2,46673 - 2,46272 - 2,45871 - 2,45470 - 2,4569 - 2,44668 - 2,44267 - 2,43866 - 2,43465 - 2,4364 - 2,42663 - 2,42262 - 2,41861 - 2,41460 - 2,4159 - 2,40658 - 2,40257 - 2,39856 - 2,39455 - 2,3954 - 2,38653 - 2,38252 - 2,37851 - 2,37450 - 2,3749 - 2,366
48 - 2,36247 - 2,35846 - 2,35445 - 2,3544 - 2,34643 - 2,34242 - 2,33841 - 2,33440 - 2,3339 - 2,32638 - 2,32237 - 2,31836 - 2,31435 - 2,3134 - 2,30633 - 2,30232 - 2,29831 - 2,29430 - 2,2929 - 2,28628 - 2,28227 - 2,27826 - 2,27425 - 2,2724 - 2,26623 - 2,26222 - 2,25821 - 2,25420 - 2,2519 - 2,24618 - 2,24217 - 2,23816 - 2,23415 - 2,18414 - 2,13413 - 2,08412 - 2,03411 - 1,98410 - 1,9349 - 1,8848 - 1,8347 - 1,7846 - 1,7345 - 1,6844 - 1,6343 - 1,5842 - 1,5341 - 1,484
0 - N/A
3V BATTERY OFFSET CHART
30 LoRaWAN™ IP68 PULSE READER UM3080
DIMENSIONS / PACKAGINGDimensions
27 mm 27 mm
109
mm
WIRING GUIDE
Wire color Function
White Digital 1
Yellow Digital 2
Brown Ground
Green Ground
31 LoRaWAN™ IP68 PULSE READER UM3080
CONTACT INFORMATIONNordic Automation Systems AS [email protected]
ORDERING INFORMATION
Product/SKU Package qty Version
UM3080x#0001xx 1 Digital
Product Qty SKURegion
ArticleRegion
UM3080 A 0001 EU#
Article region SKU region Frequency
A EU 868 MHz
B AU 922 MHz
C US 915 MHz
D AS 923 MHz
E CN 780 MHz
F KR 922 MHz
G EU 433 MHz
H CN 470 MHz
I IN 866 MHz
32 LoRaWAN™ IP68 PULSE READER UM3080
REVISION HISTORY
1.0 - First version
All content contained herein is subject to change without notice. Nordic Automation Systems reserves the right to change or modify the content at any time.