7/27/2019 Mindray DP-50 Quick Guide
http://slidepdf.com/reader/full/mindray-dp-50-quick-guide 1/2www.bcftechnology.com
Help
Exit currentstatus tothe previousstatus
Press to openor close themeasurement andcalculation reports
Press toopen/closethe set-upmenu
Time Gain Compensationincreases/decreasesbrightness of returning signalat varying depths
4. Freq/THI – Rotate tochange frequency.
7. Focus – Press toactivate then rotate tomove focal point up/downthe depth scale.
5. Depth ofview. Rotateto alterscanning
depth. Pressto zoom.
Two imageson split screen
Press for measurementpackages
Four imageson splitscreen
M mode
B mode
Press to movebetweenactive imageswhen in split
screen mode
12. Press toend the exam
2. Enterthe patientdetails
Press toshow/hideon-screenarrow
Calipers formeasuringdistance andarea
6. Gain –Increases/decreasesoverall
brightness
3. Change presetor probe(if two attached)
Press to addtext to image
8. Pressto activatemenu
Set button foruse in menus
9. Freeze image.Use trackballto scroll backthrough pausedimages to selectrequired image
10. Save 1stores stillimage,Save 2 stores
a cine-loop
F1-F4 – Assign afunction to each ofthese keyes throughset up menu
11. iStation –Access storedimages and clipsfor all patients
Press to displayor hide thebiopsy guide line
Press to deletecomments 1. On/Off button
Press toreview storedimages ofcurrent patient
Your ultrasound and X-ray people
Mindray DP-50 Quick Guide
7/27/2019 Mindray DP-50 Quick Guide
http://slidepdf.com/reader/full/mindray-dp-50-quick-guide 2/2© BCF Technology 2013
Your ultrasound and X-ray people
1. Attach relevant probe before turning on the scanner. Do not remove the probe whilst thescanner is turned on.
2. Patient – Enter patient details.
3. Probe – Ensure you are in the correct application setting (preset) for the type of exam beingperformed.
4. Frequency – Ensure that your frequency is at the correct setting. A higher frequency settingprovides higher resolution to the image, however penetration is reduced. A lower frequencysetting improves penetration ability, however resolution is diminished.
5. Depth – Adjust so that the region of interest occupies approximately ¾ of the screen.A depth scale (in centimetre increments) is displayed next to the image.
6. Gain – Increase or decrease the overall brightness of the image.
7. Focus – Move the focal point(s) up and down the depth scale until it/they are pointing atthe region of interest.
8. Menu – Press the menu button to access further image optimisation parameters. Use thetrackball to highlight individual parameters and use the set and back buttons (located tothe left/right of the trackball) to alter each parameter.
9. Measurements and calculations – Freeze the image and scroll back through the pausedimages (using the track ball) to select an appropriate image. Then press the caliper ormeasure button.
10. Save 1 or 2 – Save relevant images and cine-loops.
11. iStation – Access stored information for each exam performed, review images/cine-loops,transfer images to USB memory stick.
12. End exam – Finishes the exam of the current patient. You are then ready to repeat forscanning the next patient.
Note: All BCF Technology products are to be used for animal applications only.
UK +44 (0)1506 460 023
IRE +353 (0)42 932 0070
Mindray DP-50 Quick Guide