Modular UPS SystemS6300 20–440 kVA (n+1)

Statron’s scalable, modular 3-phase,double conversion UPS systemoffers maximum flexibility and poweravailability.

The unique system design with itsadvanced decentralized parallelarchitecture consists of fully inde-pendent and hot pluggable modules.Each module within the UPS systemconsists of a rectifier, inverter, staticbypass and its own DSP control andthus the UPS is free of commonfailure points and maximizes poweravailability.

www.statron.com

Standard features• 20 kVA or 40 kVA modules

• IGBT and MOSFET semiconductors and

DSP processors

• Input power factor 0.99

• Service friendly with hot-plug modules

• High efficiency >94%

• Input THDi <3%

• Online diagnosis and -monitoring

• Highest availability with internal redundancy

for each module

• CE mark

Options• Scalable up to 440 kVA (n+1)

• RS232 interface with MODBUS

• Monitoring software UPSMon

• Flexible communications with SNMP / LAN

• Battery monitoring

• Other options on request

Page 2: Modulare USV S6300 E

The Statron S6300 UPS is developed for mission-critical applications like datacenters, computer-con-trolled industry processes, sensitive medical equipment or machines – everywhere where highest avail-ability must be provided to secure critical loads.

Power outages or other disturbances in the power grid cannot be avoided but the downtime and reco-very costs of your system can. The S6300 uninterruptible power supply (UPS) protects mission-criticalloads against all disturbances in the power grid as shown below and provides safe and clean backuppower.

Equipment connected to the S6300 UPS is protected against the following disturbances:

Voltage Phenomenon Time Example

1. Outage /blackouts >10 ms

2. Sags /brownouts <16 ms

3. Dynamic overvoltage 4 …16 ms

4. Undervoltage continuous

5. Overvoltage continuous

6. Transients / surges <4 ms

7. Voltage distorsion (burst) alternating

8. Voltage distorsion periodical

9. Frequency variations sporadic

10. Lightning strikes sporadic

Modular UPS SystemS6300 – Application Areas

Modular UPS SystemS6300 – Highest Availability

Page 3: Modulare USV S6300 E

The service friendly concept is another great advantage of theS6300.Hot-plug modules and pre-configured parts guarantee easyand fast replacement, service and maintenance guaranteeingpower availability.

Key points in reducing the service and maintenance costs:

• Reduced MTTR (Mean Time to Repair) and maximizedsecured availability with hot-plug modules.

• Front access to all components.

• No need for trained personnel on site as the system isdesigned for “plug and play” integration.

• No spare parts stock on site needed. In case of a failureonly the module must be replaced.

Batteries and battery cabinets –modular technology

Multiple strings of sealed maintenance free long life lead acidbatteries in pre-configured battery trays simplify the installa-tion on site. Additional battery strings can be added while thesystem is running for additional back-up time.

External sealed maintenance free lead acid batteries or ventedlow maintenance lead acid batteries can be placed on a rack,in a special battery room or besides the UPS system.

Modular UPS SystemS6300 – Application Areas

Modular UPS SystemS6300 – Highest Availability

Modular UPS SystemS6300 – Low Service and Maintenance Cost

UPS Module

Battery string

Page 4: Modulare USV S6300 E

Modular n+1 Redundancy

Real redundancy and a decentralized architecture for all critical components eliminate the“single point of failure” completely.

• Hot-plug modules up to 440 kVA (n+1).

• Every module with own inverter, recitifierand static switch. No single point of failure.

• Internal, redundant power supply.

• Internal or external batteries.

• Monitored and speed controlled fans.

Modular UPS SystemS6300 – Application Areas

Modular UPS SystemS6300 – Highest Availability

Decentralized Controller

Decentralized Bypass

Decentralized Battery

DecentralizedArchitecture

2 Modules S6300

Page 5: Modulare USV S6300 E

Flexibility

The S6300 UPS is scalable up to 440 kVA (n+1) with its simple hot-plugable modules. Themodules allow flexible investments, always then when more power is required. An oversizedUPS is no longer needed.

Low operation costs

The operation costs are a key factor for every company. A modular UPS with an optimizedenergy efficiency helps to keep the operation cost as low as possible. The high efficiency of>94% even at 50% load keeps the energy consumption low.

Total cost of ownership (TCO)

Another important criteria while choosing the right UPS system is the total cost of ownership.Calculated over a full lifetime cycle the S6300 UPS has a remarkable lower TCO compared witha standard UPS system, considering key factors like investment cost, energy efficiency, lowmaintenance cost and small footprint.

Communication

State-of-the-art communication software supports themonitoring and control of the UPS, besides the displaycontrol panel.

• RS232 connection with MODBUS for monitoring.

• UPSMon control software und flexible communica-tion via SNMP and network adapter.

• The complete system can be controlled via LCDdisplay which shows an overview of the status andthe most important information.

• All alarms are shown in easy to understand text.

Modular UPS SystemS6300 – Optimized Costs with high scalability and efficiency

Modular UPS SystemS6300 – Technical Specification

Display

HTML Status monitoring

Page 6: Modulare USV S6300 E

3 ph Output

Model 20 kVA Modules S6300-20 S6300-40 S6300-60 S6300-80 S6300-100 S6300-120-220

Power Rating (p.f. = 0.8 ind.) 20 kVA 40 kVA 60 kVA 80 kVA 100 kVA 120–220 kVA

Number of power modules (n+1) 2 3 4 5 6 max. 12

Nominal output power (p.f. 1) 16 kW 32 kW 48 kW 64 kW 80 kW max. 176 kW

Dimension (mm, W2D2H) 600280021800 22600280022000

Model 40 kVA Modules S6300-40 S6300-80 S6300-120 S6300-160 S6300-200 S6300-240-440

Power Rating (p.f. = 0.8 ind.) 40 kVA 80 kVA 120 kVA 160 kVA 200 kVA 240–440 kVA

Number of power modules (n+1) 2 3 4 5 6 max. 12

Nominal output power (p.f. 1) 32 kW 64 kW 96 kW 128 kW 160 kW max. 352 kW

Dimension (mm, W2D2H) 22800280021800 …22000 22800280022000

General

Efficiency (AC-AC, online) >94% (50–100% load)

Ambient conditions 0–40 °C, <95% rh (non condensing), <1000 m a.s.l.

Audible noise <60 dB(A)

EMC compatibility IEC 62040

Protection degree IP 20 (up to IP 54 optional)

Design standards IEC / EN 62040

Input

Input voltage (3 ph + N) 32400 / 230 VAC +15% / –20%

Frequency 50 / 60 Hz ±5%

Input power factor 0.99 (>0.97 at 25% load)

Input harmonic current distortion(THDi)

<4%

DC-circuit

Number of cells (typically) 22110 – 22140 (lead acid battery)

Ripple voltage <1%

Output

Output voltage (3 ph + N) 380–415 VAC

Output frequency 50 / 60 Hz ±0.01%

Output voltage stability

– static– dynamic (0–100%–0)– unbalanced load (100%)– regulation time (±1%)

±1%±5%±2%20 ms

Overload capability 125% for 10 min150% for 1 min200% for 3 sec

500% for 100 ms (bypass)

Total harmonic distortion

– linear load– non-linear load

<2%<5%

Crest factor 3:1

Quality / Environment ISO 9001:2008; ISO 14001

Further data available on request © 2011 Statron AG, data subject to change without notice

Statron AG • Industrie Nord • CH-5506 Mägenwil • SwitzerlandPhone +41 62 887 4 887 • Fax … 888E-mail: [email protected] • www.statron.com

Modular UPS SystemS6300 – Optimized Costs with high scalability and efficiency

Modular UPS SystemS6300 – Technical Specification

Modules 20 kVA up to max. 220 kVA (n+1)Modules 40 kVA up to max. 440 kVA (n+1)