Good 3G Celref is needed for proper analysisLOGFILE CELL EVENT
ONITSHA CLS _200714_6.log. 4073GC 1 X Dropped call
ONITSHA CLS _200714_6.log. DL0003V1 X Dropped call
ONITSHA CLS _200714_6.log. 1 X Blocked call
ONITSHA CLS _200714_7.log. 4194GD 1 X Dropped call
ONITSHA CLS _200714_8.log. 4109GF 1 X Dropped call
s ONITSHA CLS _200714_8.log. 4029GB 1 X Dropped call
ONITSHA CLS _200714_12.log. AN0117X 1 X Dropped call
ONITSHA CLS _200714_14.log. AN0130V 1 X Dropped call
ONITSHA CLS _200714_23.log. 4034GB/GD 10 X Blocked call
ONITSHA CLS _200714_23.log. 4016GB 1 X Dropped call
ONITSHA CLS _200714_23.log. 2829GA 1 X Dropped call
ONITSHA CLS _200714_23.log. 160GE1 X Dropped call
ONITSHA CLS _200714_30.log. AN0561Y 1 X Dropped call
ONITSHA CLS _210714_01.log. 4833GD1 X Dropped call
ONITSHA CLS _210714_01.log. 4833GD2 X Blocked call
ONITSHA CLS _210714_01.log. AN0047W 1 X Dropped call
ONITSHA CLS _210714_01.log. 4007GE 1 X Dropped call
ONITSHA CLS _210714_01.log. AN0552Y 1 X Dropped call
REASON
Detected Missing neighbour
Poor coverage around 4091.
Poor/coverage from cell 4194GD
Suspected feeder swap
Late SHO
Detected Missing neighbour
Pilot Pollution
Suspected transmission issue
Detected Missing neighbour
Detected Missing neighbour
Poor quality due detected Missing neighbour
Suspected hardware failure/transimission issue
Suspected hardware failure/transimission issue
Detected Missing neighbour
Detected Missing neighbour
Detected Missing neighbour
Pilot Pollution from DL0003V(at distance of 3.21km)
Poor coverage and quality due detected Missing neighbour
COMMENT/ACTION
Add 4073GC and 4025GC as neighbour to each other
Electrical downtilt of +2 on DL0003V to reduce its Pilot Power
Check 4091GB for any alarm/antenna fault.
Down tilt 4194GD
Resolve the suspected feeder swap on 4109
Review SHO between 4029GB and 4029GA
Add AN0117X and AN0025X as neighbour to each other
Electrical down tilt of +2 on AN0130V
Check 4034GD for any transmission issue as no call was establised on it.
Check and add 4016GB,4074GB and 400GC as neighbour to each other.
Add 2829GA and 4836GA as neighbour to each other.
Add 160GE and 2829GF as neighbour to each other.
Add AN0561Y and 4879GE as neighbour to each other.
Check 4833GD for any transmission related issue.
Check 4833GD for any transmission related issue.
Add AN0047W and 219GC as neighbour to each other
Add 4007GE and AN0552Z as neighbour to each other.
Add 4061GE and AN0552Y as neighbour to each other.
LOGFILE CELL EVENT
ONITSHA CLS _200714_6.log.4045B 1 X Dropped call
ONITSHA CLS _200714_6.log. AN0056A 1 X Blocked call
ONITSHA CLS _200714_6.log. 285A 1 X Dropped call
ONITSHA CLS _200714_7.log. 4073B 2 X Dropped call
ONITSHA CLS _200714_8.log. 4041DA 1 X Blocked call
ONITSHA CLS _200714_8.log. 4145DB 1 X Dropped call
ONITSHA CLS _200714_13.log. 4103DB 1 X Dropped call
ONITSHA CLS _200714_13.log. 159B 1 X Blocked call
ONITSHA CLS _200714_13.log. 4039B 1 X Dropped call
ONITSHA CLS _200714_14.log. AN0025B 1 X Dropped call
ONITSHA CLS _210714_01.log.AN0563B 1 X Dropped call
ONITSHA CLS _210714_01.log. AN0047A 1 X Dropped call
ONITSHA CLS _210714_01.log. AN0036B 2 X Blocked call
ONITSHA CLS _210714_01.log. 4061
REASON
Poor coverage
Poor coverage due to availabity issue on 4837
Poor coverage/quality
Poor coverage/quality due to unstable availability on 4024B
Poor coverage due to missing neighbour
Congestion on TCH
Poor quality caused by co-channel interference.
Poor quality .
TCH congestion AN0047A
Poor coverage on the serving cell AN0036B
Poor coverage/quality due to outage of 4061
Poor coverage/quality distance cell 4045B due to availability issue of 4091B
Poor coverage/quality due to late handover to a better neighbour cell 4045B even when the coverage get bad
Poor coverage and bad quality due to unstable availability on 4833
COMMENT/ACTION
Check and resolve suspected alarms/feeder fault on 4091B.
Review handover parameter between AN0056A and AN0023B
Resolve and normalise the availability of 4837A
Review/adjust handover parameter between 4073B and 4045B
Mechanical Up tilt is recommended on 4041DA to improve coverage.
Check the coverage of 4024 and stabilize it.
Add 4103DB and 4103C as neighbour to each other
Frequency retune on 4039B(BCCH-91) and AN0054A(BCCH-91)
Electrical down tilt of +1 on AN0025B to allow dominance of closer cell.
Resolve and normalise the availability of 4833
Normalised now need to be monitor,also nomalise the availability of 4833
Check AN0036B for faulty hardware/Antenna
Brings 4061 back on air.