COLUMBIA CARE10615 East Colonial Drive,
Orlando, FL 32817
OWNER:Greg MurphyCOLUMBIA CARE70 Industrial AvenueLowell, MA 01852
N
PLUMBING, HVAC & ELECTRICALENGINEER:Brett J. GarnerBergmann Associates8375 Dix Ellis Trail,Building 600, Suite 105,Jacksonville, FL 32256(904) 760-4510
ARCHITECT:Bruce HamptonElton + Hampton Architects103 Terrace StreetRoxbury, MA 02120(617) 708-1071
Permit Set: March 27, 2019REVISED: MAY 7, 2019
Str
eet
Vie
wL
ocu
s M
ap
Project number
Date
Drawn by
Checked by
70 Industrial Avenue EastLowell, MA 01852
ELTON HAMPTON ARCHITECTS103 Terrace StreetBoston, MA 02120617-708-1071
PROJECT
1 of
OWNER:
\\ehadc\Server\Projects\Mayerson -Orlando\Revits\Mayerson - Colonial Drive.rvt
G-000.00
Cover Sheet
--
10615 E. Colonial Dr.
Columbia Care
03.27.2019
JC
BH
Orlando, FL 32803
No. Description Date
1 Revisions for Permit Review 05.07.19
DRAWING LIST
G-000.00 Cover SheetG-000.01 Responsibility Matrix
D-000.00 Demolition Floor Plan
A-000.00 Site PlanA-001.00 Proposed Floor PlanA-001.01 Reflected Ceiling PlanA-001.02 Proposed Flooring PlanA-001.03 Roof PlanA-002.00 Building ElevationsA-002.01 Building ElevationsA-002.02 Building SectionsA-003.00 Schedules, Wall Types
& Interior SignageA-003.01 Interior ElevationsA-003.02 Interior ElevationsA-004.00 Proposed Life Safety PlanA-005.00 Point of Sales Station DetailsA-005.01 RACKKS System
M-101.00 Mechanical Renovation PlanM-500.00 Mechanical DetailsM-600.00 Mechanical Schedules
P-101.00 Plumbing PlanP-500.00 Plumbing DetailsP-600.00 Plumbing Schedules
E-001.00 Electrical Symbols ListE-101.00 Power & Fire Alarm Floor PlanE-102.00 Electrical Roof planE-201.00 Lighting Floor PlanE-301.00 Security Floor PlanE-501.00 DetailsE-502.00 DetailsE-701.00 SchedulesE-702.00 SchedulesE-801.00 Electrical SpecificationsE-802.00 Electrical SpecificationsE-803.00 Electrical Specifications
1
ANY & ALL SIGNAGE DEPICTED WITHIN THIS SET IS SCHEMATIC IN NATURE. ANY APPROVALRECEIVED FOR PERMIT (#19901966) DOES NOT CONSTITUE APPROVAL FOR THE CONSTRUCTION OFANY SIGN/SIGN STRUCTURE COVERED WITHIN ORANGE COUNTY CODE SECTION 31.5. SIGNAGEMUST COMPLY WITH ORANGE COUNTY CODE, CHAPTER 31.5 OR ANY APPLICABLE APPROVED SIGNPLAN. ALL PROPOSED SIGNAGE, INCLUDING SIGNAGE STRUCTURES, ARE REQUIRED TO SUBMIT ASEPARATE APPLICATION AND SHALL BE SUBMITTED THROUGH THE BUILDING PERMIT RESIDENTIALPROCESS FOR REVIEW BY ZONING, BUILDING AND DEVELOPMENT ENGINEERING.
1
1
REF. DW
OTG
11686B
6711
6711
671167
11
6711
REF.
UNDERCOUNTERFRIDGE
584 SF
RECEIVING/SHIPPING/BREAKROOM
52 SF
MECHANICALROOM
43 SF
ELECTRICALROOM
139 SF
OFFICE
94 SF
DRIVE THRU
360 SF
VAULT
21 SF
QUARANTINE
93 SF
STORAGE
125 SF
CORRIDOR67 SF
STAFFBATHROOM
9 SF
STORAGE
DRINKINGFOUNTAIN
44 SF
STORAGE50 SF
HEAD END
136 SF
KITCHEN
88 SF
HC BATHROOM
REF. DW
OTG
11686B
6711
6711
671167
11
6711
REF.
UNDERCOUNTERFRIDGE
584 SF
RECEIVING/SHIPPING/BREAKROOM
52 SF
MECHANICALROOM
43 SF
ELECTRICALROOM
139 SF
OFFICE
94 SF
DRIVE THRU
360 SF
VAULT
21 SF
QUARANTINE
93 SF
STORAGE
125 SF
CORRIDOR67 SF
STAFFBATHROOM
9 SF
STORAGE
DRINKINGFOUNTAIN
44 SF
STORAGE50 SF
HEAD END
136 SF
KITCHEN
88 SF
HC BATHROOM
P-101.00
PLUMBING PLANS
14054.04
Project number
Date
Drawn by
Checked by
03.26.2019
No. Description Date
10615 E Colonial Drive
PROJECT
Orlando, FL 32817
EVAN W. GRAVES, P.E.
LICENSE NUMBER 82873
70 Industrial Avenue East
Lowell, MA 01852
ELTON HAMPTON ARCHITECTS
103 Terrace Street
Boston, MA 02120
617-708-1071
OWNER:
Columbia Care
MEP ENGINEERS:
Six Tower Bridge, Suite 430181 Washington StreetConshohocken, PA 19428
office: 610.834.4080fax: 610.834.4394
www.bergmannpc.com
Bergmann Associates, Architects, Engineers,Landscape Architects & Surveyors, D.P.C., P.A.
1 Plan Review Comments 05/07/19
2 Plan Review Comments 06/05/19
DT
EG
DRAIN, WASTE & VENT PLANSCALE:1/4=1'-0"
1
KEY NOTES
GENERAL NOTES
DOMESTIC WATER PLANSCALE:1/4=1'-0"
2
LEGEND
DEMOLITION GENERAL NOTES
2
P-500.00
PLUMBING DETAILS
DT
EG
14054.04
Project number
Date
Drawn by
Checked by
03.26.2019
No. Description Date
10615 E Colonial Drive
PROJECT
Orlando, FL 32817
EVAN W. GRAVES, P.E.
LICENSE NUMBER 82873
70 Industrial Avenue East
Lowell, MA 01852
ELTON HAMPTON ARCHITECTS
103 Terrace Street
Boston, MA 02120
617-708-1071
OWNER:
Columbia Care
MEP ENGINEERS:
Six Tower Bridge, Suite 430181 Washington StreetConshohocken, PA 19428
office: 610.834.4080fax: 610.834.4394
www.bergmannpc.com
Bergmann Associates, Architects, Engineers,Landscape Architects & Surveyors, D.P.C., P.A.
1 Plan Review Comments 05/07/19
2 Plan Review Comments 06/05/19
PLUMBING SPECIFICATIONSPART 1 - GENERAL1.1 SUBMITTALS
A. PRODUCT DATA: FOR EACH TYPE OF PRODUCT INDICATED.PART 2 - PRODUCTS2.1 PIPING MATERIALS
A. COMPLY WITH REQUIREMENTS IN "PLUMBING PIPING SCHEDULE" INDICATED ON DRAWINGS FORAPPLICATIONS OF PIPE, TUBE, AND FITTING MATERIALS, AND FOR JOINING METHODS, INSULATION, ANDHANGING REQUIREMENTS FOR SPECIFIC SERVICES, SERVICE LOCATIONS, AND PIPE SIZES.
2.2 VALVESA. NSF COMPLIANCE: NSF 61 AND NSF 372 FOR VALVE MATERIALS FOR POTABLE-WATER SERVICEB. WATER SHUTOFF SERVICE: TWO-PIECE, FULL-PORT, BRASS BALL VALVES WITH BRASS TRIMC. CHECK VALVES: BRASS SILENT CHECK VALVES WITH NONMETALLIC DISC SUITABLE FOR HORIZONTAL OR
VERTICAL INSTALLATION2.3 HANGERS AND SUPPORTS
A. PROVIDE HANGERS INDICATED ON DRAWINGS.B. WALL SUPPORTS
1. PIPING 3” AND SMALLER: STEEL RISER CLAMPC. VERTICAL SUPPORT: STEEL RISER CLAMP
2.4 PLUMBING FIXTURESA. PROVIDE FIXTURES INDICATED ON DRAWINGS.B. LEAD-FREE COMPLIANCE: FIXTURES AND FIXTURE TRIM SHALL COMPLY WITH THE REQUIREMENTS OF
NSF 61 ANNEX G AND NSF 372 FOR LAVATORIES, SINKS AND WATER COOLERS.C. DISABLED ACCESS: CONFORM TO APPLICABLE LOCAL, STATE OR FEDERAL DISABLED ACCESS
REQUIREMENTS FOR THE INSTALLATION, MOUNTING HEIGHTS, AND OPERATION OF PLUMBING FIXTURE.D. PRODUCTS REQUIRING ELECTRICAL CONNECTION: LISTED AND CLASSIFIED BY UNDERWRITER'S
LABORATORIES, INCORPORATED, AND ACCEPTABLE TO THE AUTHORITY HAVING JURISDICTION ASSUITABLE FOR THE PURPOSE SPECIFIED AND INDICATED.
E. OPERATION AND MAINTENANCE DATA: INCLUDE MANUFACTURER'S DESCRIPTIVE LITERATURE,OPERATING INSTRUCTIONS, MAINTENANCE AND REPAIR DATA, AND PARTS LISTING FOR PLUMBINGFIXTURES.
PART 3 - EXECUTION3.1 PIPING INSTALLATION
A. INSTALL ESCUTCHEONS AT EACH WALL, FLOOR, AND CEILING PENETRATION IN EXPOSED FINISHEDLOCATIONS AND WITHIN CABINETS AND MILLWORK. USE DEEP PATTERN ESCUTCHEONS WHEREREQUIRED TO CONCEAL PROTRUDING PIPE FITTINGS.
B. INSTALL SLEEVES FOR PIPING PENETRATIONS OF WALLS, CEILINGS, AND FLOORS.C. INSTALL SLEEVE SEALS FOR PIPING PENETRATIONS OF CONCRETE WALLS AND SLABS.D. MAKE SOLDERED JOINTS USING "LEAD FREE" SOLDER AND A NON-CORROSIVE, PASTE-TYPE FLUX. CORE
SOLDER IS NOT PERMITTED. SOLDER SHALL BE SOLID STRING OR WIRE TYPE. WHERE SOLDEREDCOPPER PIPING IS CONNECTED TO THREADED BRASS PIPING, USE CAST BRASS ADAPTOR.
E. PLACE PLUGS IN ENDS OF UNCOMPLETED PIPING AT END OF EACH DAY OR WHEN WORK STOPS.F. MINIMUM SLOPE OF HORIZONTAL DRAIN PIPING SHALL BE 1/4” PER FOOT FOR PIPING 2 1/2” OR LESS AND
1/8” PER FOOT FOR PIPING 3” AND LARGER.G. MAKE CHANGES IN DIRECTION IN DRAIN PIPING WITH INDIVIDUAL EIGHTH BENDS AND WYES.H. QUARTER BENDS, SWEEPS, TEES, AND COMBINATION WYE & EIGHTH BEND FITTINGS ARE NOT PERMITTED
FOR USE ON DRAIN PIPING.I. PIPE BEDDING AND BACKFILLING
1. EXCAVATE TRENCHES FOR PIPE TO 4 INCHES BELOW BOTTOM OF PIPE.2. PLACE 4 INCHES OF BEDDING MATERIAL, COMPACT IN BOTTOM OF TRENCH, AND SHAPE TO
CONFORM TO LOWER PORTION OF PIPE BARREL.3. BACKFILL AND COMPACT IN ACCORDANCE WITH FILL AND COMPACTION REQUIREMENTS IN ASTM
D2321 .4. SUPPORT PIPE DURING PLACEMENT AND COMPACTION OF BEDDING FILL.5. PROVIDE BEDDING MATERIALS FROM 4 INCHES UNDER THE OUTSIDE BOTTOM OF THE PIPE TO 12
INCHES OVER THE OUTSIDE TOP OF THE PIPE.6. MATERIALS:
I. GRANULAR FILL, MEETING ASTM D2231II. COARSE AGGREGATE DRAIN STONEIII. ANGULAR, 0.25-INCH TO 0.75-INCH, GRADED STONE.IV. 500 PSI COMPRESSIVE STRENGTH CONCRETE.
J. PEX TUBING1. PROTECT TUBING ROUTED THROUGH METAL STUDS WITH GROMMETS OR SLEEVES AT EACH STUD.2. PROVIDE ADEQUATE TUBING LENGTH FOR CONTRACTION AND EXPANSION OF TUBING.3. MANIFOLD SYSTEMS ARE NOT ACCEPTABLE.4. TUBING MAY BE BUNDLED. DO NOT BUNDLE COLD WATER LINES WITH HOT WATER OR HOT WATER
RETURN LINES.5. PROVIDE RIGID PIPING AT INLET AND OUTLET OF WATER HEATERS, MINIMUM 18 INCHES LONG.6. USE RIGID STUB-OUTS AND STUB-OUT BRACKETS SECURED TO WALL FOR FIXTURES.7. TUBING COLOR:
I. COLD WATER: BLUEII. HOT WATER AND RECIRC: REDIII. ALL OTHERS: WHITE
K. PROTECT PLASTIC PIPING AND TUBING FROM UV RADIATION DURING PRE-INSTALLATION STORAGE ANDAFTER INSTALLATION.
3.2 JOINT CONSTRUCTIONA. REAM ENDS OF PIPES AND TUBES AND REMOVE BURRS. BEVEL PLAIN ENDS OF STEEL PIPE.B. REMOVE SCALE, SLAG, DIRT, AND DEBRIS FROM INSIDE AND OUTSIDE OF PIPES, TUBES, AND FITTINGS
BEFORE ASSEMBLY.C. THREADED JOINTS: THREAD PIPE WITH TAPERED PIPE THREADS ACCORDING TO ASME B1.20.1. CUT
THREADS FULL AND CLEAN USING SHARP DIES. REAM THREADED PIPE ENDS TO REMOVE BURRS ANDRESTORE FULL ID. JOIN PIPE FITTINGS AND VALVES AS FOLLOWS:1. APPLY APPROPRIATE TAPE OR THREAD COMPOUND TO EXTERNAL PIPE THREADS.2. DAMAGED THREADS: DO NOT USE PIPE OR PIPE FITTINGS WITH THREADS THAT ARE CORRODED OR
DAMAGED.D. DISSIMILAR-MATERIAL PIPING JOINTS: MAKE JOINTS USING ADAPTERS COMPATIBLE WITH MATERIALS OF
BOTH PIPING SYSTEMS.
3.3 HANGERS AND SUPPORT INSTALLATIONA. SUPPORT PIPES THROUGHOUT BUILDING, BOTH HORIZONTALLY AND VERTICALLY IN ACCORDANCE WITH
REQUIREMENTS HEREIN AND AS SHOWN ON THE DRAWINGS. DO NOT USE FASTENERS WHICHPENETRATE THE ROOF DECK.
B. IN BUILDINGS WITH OPEN WEB JOISTS, HANGERS AND SUPPORTS SUSPENDED FROM ABOVE MUST BESUPPORTED FROM TOP CHORD OF JOIST WITHIN 6” OF PANEL POINT. DO NOT ATTACH HANGERS ANDSUPPORTS TO BOTTOM CHORD OF JOISTS OR WEBBING.
C. PROVIDE COPPER PLATED HANGERS AND SUPPORTS FOR UNINSULATED COPPER PIPING. PROVIDEPLASTIC INSERTS FOR UNINSULATED COPPER PIPING PENETRATING METALS STUDS.
D. IN AREAS WITHOUT CEILINGS, SECURE INSULATION SHIELDS TO INSULATION WITH PRESSURE SENSITIVETAPE AT EACH END OF SHIELD.
E. INSTALL HANGERS TO PROVIDE MINIMUM 1/2” CLEAR SPACE BETWEEN FINISHED COVERING ANDADJACENT WORK.
F. PLACE A HANGER WITHIN ONE FOOT OF EACH HORIZONTAL ELBOW.G. SUPPORT VERTICAL PIPE RUNS AT ROOF, AT FLOOR, AND AT MAXIMUM 15-FOOT INTERVALS.H. SPACE SUPPORTS NOT MORE THAN FIVE FEET APART AT VALVES, STRAINERS OR PIPING ACCESSORIES
LARGER THAN 2”.I. INSTALL LATERAL BRACING WITH PIPE HANGERS AND SUPPORTS TO PREVENT SWAYING.J. INSTALL HANGERS AND SUPPORTS TO ALLOW CONTROLLED THERMAL AND SEISMIC MOVEMENT OF
PIPING SYSTEMS, TO PERMIT FREEDOM OF MOVEMENT BETWEEN PIPE ANCHORS, AND TO FACILITATEACTION OF EXPANSION JOINTS, EXPANSION LOOPS, EXPANSION BENDS, AND SIMILAR UNITS.
K. ADJUSTING1. HANGER ADJUSTMENTS: ADJUST HANGERS TO DISTRIBUTE LOADS EQUALLY ON ATTACHMENTS AND
TO ACHIEVE INDICATED SLOPE OF PIPE.2. LOAD DISTRIBUTION: ADJUST HANGERS AND SUPPORTS SO THAT PIPING LIVE AND DEAD LOADS AND
STRESSES FROM MOVEMENT WILL NOT BE TRANSMITTED TO CONNECTED EQUIPMENT.3. PIPE SLOPES: ADJUST HANGERS AND SUPPORTS TO PROVIDE INDICATED PIPE SLOPES AND TO NOT
EXCEED MAXIMUM PIPE DEFLECTIONS ALLOWED BY ASME B31.9 FOR BUILDING SERVICES PIPING.4. TRIM EXCESS LENGTH OF CONTINUOUS-THREAD HANGER AND SUPPORT RODS TO 1-1/2”.
3.4 PIPE INSULATION INSTALLATIONA. INSULATE FITTINGS AND VALVES WITH PREFORMED INSULATION FITTINGS WITH PVC JACKET.
3.5 PLUMBING FIXTURE INSTALLATIONA. PROVIDE EACH FIXTURE COMPLETE WITH REQUIRED TRIM.B. EXPOSED PIPING AND TRIM SHALL BE POLISHED CHROME-PLATED BRASS.C. PROVIDE EACH FIXTURE WITH CHROME-PLATED BRASS, QUARTER-TURN ANGLE STOP VALVES.D. ROUGH-IN FIXTURE PIPING CONNECTIONS IN ACCORDANCE WITH MINIMUM SIZES INDICATED ON
DRAWINGS FOR PARTICULAR FIXTURES.E. EXAMINE SURFACES AND ADJACENT AREAS WHERE PRODUCTS WILL BE INSTALLED. VERIFY THAT
CONDITIONS CONFORM TO PRODUCT MANUFACTURER'S REQUIREMENTS AND INSTALLATIONCONDITIONS. DO NOT PROCEED UNTIL UNSATISFACTORY CONDITIONS HAVE BEEN CORRECTED. VERIFYTHAT WALLS AND FLOOR FINISHES ARE PREPARED AND READY FOR INSTALLATION OF FIXTURES. VERIFYTHAT PLUMBING PIPING FOR FIXTURE IS IN THE CORRECT LOCATION AND OF THE CORRECT TYPE.
F. INSTALL FIXTURES AND TRIM IN ACCORDANCE WITH MANUFACTURER'S PUBLISHED INSTRUCTIONS. MAKEFINAL CONNECTIONS.
G. SUPPORT EACH FIXTURE IN A RIGID MANNER WHICH PERMITS NO PERCEPTIBLE MOVEMENT OF FIXTUREBY MANUALLY APPLIED FORCES.
H. INSTALL TRAP ON FIXTURE OUTLET EXCEPT FOR FIXTURES HAVING INTEGRAL TRAP. INSTALL EACHFIXTURE WITH TRAP WHICH IS EASILY REMOVABLE FOR SERVICING AND CLEANING.
I. INSTALL COMPONENTS LEVEL AND PLUMB.J. INSTALL TOILET SEATS ON WATER CLOSETS.K. INSTALL WATER CLOSET AND URINAL MANUAL FLUSH LEVERS/HANDLES/BUTTONS ON OPEN SIDE OF
FIXTURE (SIDE OPPOSITE OF CLOSEST ADJACENT WALL).L. INSTALL ACCESSIBLE URINALS AT HEIGHTS INDICATED ON ARCHITECTURAL DOCUMENTS WHEN
PROVIDED.M. INSTALL AND SECURE FIXTURES IN PLACE WITH CARRIERS AND BOLTS.N. SEAL FIXTURES TO WALL AND FLOOR SURFACES WITH SILICONE SEALANT, COLOR TO MATCH FIXTURE.O. SET MOP BASINS IN LEVELING BED OF CEMENT GROUT.P. INSTALL INSULATION KITS ON ADA COMPLIANT SINK AND LAVATORY WASTE, CONTINUOUS WASTES, HOT
AND COLD WATER SUPPLIES WHERE INDICATED ON THE DRAWINGS AND AS REQUIRED BY THE ADA.Q. INSPECT FAUCETS, FLUSH VALVES, STOP VALVES, AND SIMILAR DEVICES, TO DETERMINE THAT THEY
OPERATE PROPERLY AND DISCHARGE PROPER QUANTITIES OF WATER. CORRECT ANY DEFICIENCIES.OPERATE AND ADJUST STOPS OR VALVES FOR INTENDED WATER FLOW RATE TO FIXTURES WITHOUTSPLASHING, NOISE OR OVERFLOW.
R. REPLACE WASHERS AND SEALS OF LEAKING AND DRIPPING FAUCETS AND STOPS.S. CLEAN FIXTURES, TRIM, AND ACCESSORIES OF FOREIGN MATERIALS, INCLUDING LABELS.
3.6 VALVE AND SPECIALTIES INSTALLATIONA. INSTALL WATER HAMMER ARRESTERS IN WATER PIPING ACCORDING TO PDI-WH 201.B. PROVIDE DEEP SEAL P-TRAPS FOR FLOOR DRAINS AND MOP BASINS.C. FOR CLEANOUTS LOCATED IN CONCEALED PIPING, INSTALL CLEANOUT WALL ACCESS COVERS, OF TYPES
INDICATED, WITH FRAME AND COVER FLUSH WITH FINISHED WALL.D. PROTECT DRAINS DURING CONSTRUCTION PERIOD TO AVOID CLOGGING WITH DIRT OR DEBRIS AND TO
PREVENT DAMAGE FROM TRAFFIC OR CONSTRUCTION WORK.3.7 DISINFECTION OF DOMESTIC PIPING SYSTEMS
A. USE METHOD PRESCRIBED BY THE APPLICABLE STATE OR LOCAL CODES, HEALTH AUTHORITY OR WATERPURVEYOR HAVING JURISDICTION, OR IN THE ABSENCE OF ANY OF THESE FOLLOW AWWA C651 ORLATEST EDITION OF INTERNATIONAL PLUMBING CODE.
3.8 TESTINGA. PLUMBING SYSTEMS AND DEVICES SHALL BE TESTED IN ACCORDANCE WITH STATE OR LOCAL CODES,
HEALTH AUTHORITY OR WATER PURVEYOR HAVING JURISDICTION, OR IN THE ABSENCE OF ANY OFTHESE ADHERE TO REQUIREMENTS OF LATEST EDITION OF INTERNATIONAL PLUMBING CODE.
B. PEX PIPING SYSTEMS SHALL BE TESTED IN ACCORDANCE WITH THE MANUFACTURER'S REQUIREMENTS.
ELECTRIC TANK WATER HEATERNTS
DRAIN OR CLEANOUT TO BE REMOVEDNTS
PIPE HANGER DETAILSSCALE:1/4=1'-0"
3
PLUMBING SUPPLY RISERSCALE:1/4=1'-0"
1PLUMBING DRAINAGE RISERSCALE:1/4=1'-0"
2
1
1
P-600.00
PLUMBING SCHEDULES
14054.04
Project number
Date
Drawn by
Checked by
03.26.2019
No. Description Date
10615 E Colonial Drive
PROJECT
Orlando, FL 32817
EVAN W. GRAVES, P.E.
LICENSE NUMBER 82873
70 Industrial Avenue East
Lowell, MA 01852
ELTON HAMPTON ARCHITECTS
103 Terrace Street
Boston, MA 02120
617-708-1071
OWNER:
Columbia Care
MEP ENGINEERS:
Six Tower Bridge, Suite 430181 Washington StreetConshohocken, PA 19428
office: 610.834.4080fax: 610.834.4394
www.bergmannpc.com
Bergmann Associates, Architects, Engineers,Landscape Architects & Surveyors, D.P.C., P.A.
1 Plan Review Comments 05/07/19
2 Plan Review Comments 06/05/19
DT
EG
1