Welcome to Demo on…
From
What is PITOPS? It is process control software for industries
and universities. It identifies transfer functions. It optimizes PID tuning parameters. It can be used to design APC (Advanced
Process Control) inside the DCS or PLC. It is an Industrial Tool for the Control Room
and a Training Tool for Research and Teaching in Colleges.
PITOPS is a Major New Invention
Pitops identifies multivariable transfer functions
with closed-loop data in just minutes!
Pitops tunes PIDs precisely meeting plant needs.
Pitops can be used to develop APC (Advanced
Process Control) systems inside the DCS or PLC
much better and less expensive than MPC (model
predictive control).
PITOPS algorithm is
new and superior to
any other technology
from any competitor
Let’s Tune a
PID in 3
Minutes
PID Tuning Illustration
AI
Gas Phase
Reactor
AC
FC FI
PPM Gas
CompositionPPM Gas Composition
Cascade PID Controller
SP
(Setpoint)
Gas Flow Into
Reactor
Gas phase composition is controlled by a cascade PID analyzer controller (AC),
whose output (OP) manipulates the setpoint (SP) of a slave flow controller.
We illustrate the tuning of the AC which has slow and complex dynamics.
Gas Flow
Indicator
Slave Flow
Controller
Read Plant Data from Excel or OPCPitops then reads PID PV,
the Controlled Variable
Pitops also reads PID OP,
the Manipulated Variable
We specify the
Excel Filename
First, Pitops reads data
from Excel or OPC.
Select Transfer Function Order
Gas Composition
PV Data
AC Output Data
Next, we chose the
Model Order – First
Order in this case.
Identify Transfer Function
Click here to Identify Transfer
Function Parameters
Transfer Function Parameters
The BLUE trend is the Transfer
Function Model Prediction
See transfer Function
Parameters Identified:
Dead Time=18 minutes
Process Gain=32.8
Time Constant=35.8 minutes
Notice there are no step tests in the MV
(this is complete closed-loop data)
PID Tuning OptimizationFirst, set the CV range, in our example,
range of the AC (analyzer controller)
Next, set the MV range, the
output range of the AC
Now we proceed to PID
Tuning Optimization
Optimize PID TuningNext, click on “Optimize PID Tuning”
Notice the Setpoint Change, Blue Trend
See the optimized PV Response
Examine the AC (PID) OP – Output Trajectory
See Calculated Optimum
PID Tuning Parameters
The entire process of PID Tuning including
transfer function identification took…..
Only 3 Minutes and
10 Clicks
And it was so Easy, Fast and
Convenient!
No other competitor software,
technology or algorithm can match the
power, ease and functions of PITOPS
Add Disturbances, Noise and Optimize PID Tuning for
Setpoint Change + Disturbances
14
Add Simulated
Disturbance to PVCV Response
Setpoint Change
PID Output
Effect of
disturbance
on PV
Pitops optimizes PID tuning for the
custom plant needs comprising of
typical Setpoint change, and typical
noise and disturbances seen in the
plant. Pitops tuning optimization is
proven to be superior to any other
technology or rules published
worldwide. Simulations can be built
and made to mimic the real plant in
just minutes.
Pitops optimized tuning results are not just
heuristic-based and are superior to IMC, Lambda
Tuning, Ziegler-Nichols, Cohen-Coon and others.
Multivariable
Identification
Pitops can process multivariable inputs and outputs (MIMO systems). See
a three input multivariable identification below. Pitops identifies Three
transfer functions simultaneously using complete Closed-Loop data.
MV#1
(Input #1)
+
Transfer
Function #1
Transfer
Function #2
Transfer
Function #3
MV#2
(Input #2)
MV#3
(Input #3)
CV
(Output)
++
MV#1
MV#3
MV#2
CV
MV#3 is
Reboiler Steam
MV#1 is
Column Feed
MV#2 is Reflux
CV is Overheads
Product Purity
See next slide showing plant data
and Pitops identification
Three Input Identification (continue above example)
Red Trend Shows Product Analysis (CV Data)
MV #1 Data (Column Feed)
MV #2 Data (Reflux)
MV #3 Data (Reboiler Steam)
Continuing above example, the blue trend Shows a Three-
Input Transfer Function Prediction Identified by Pitops
This Multivariable Closed-Loop Transfer Function
Identification is based on purely Closed-Loop Data (No
Step Tests) – A Unique and Unmatched Function in Pitops
Three transfer functions
(2nd Order + Dead Time)
are simultaneously Identified
PITOPS works with Oscillatory Data
(Competitor tools FAIL with such data )
PITOPS Complete Closed-Loop Identification
Competitor software needs step tests on PID OP in manual mode
PID
Output
Or, competitor software needs step tests on Setpoint in Auto mode
Setpoint PID
PV
Only PITOPS can identify transfer functions without any step tests
Setpoint (no steps)
PID
PV
PITOPS ability to reject Unmeasured
Disturbances – New 3G Algorithm
Unmeasured disturbance causing PV to
erroneously go down
PV
PV
PITOPS Transfer Function
(Disturbance Rejected)Competitor Tools
(Disturbance Fools Transfer Fn.)
CorrectError
PITOPS 3G
Technology
(Superior)
Conventional
ARMAX Method
(Obsolete)
PITOPS can Identify Control Valve Stiction
even with closed-loop data with multi-inputs
Multiple Cascades
Pitops can be used to tune any number of cascade PIDs in a long chain.
The whole process takes just minutes and is very novel and simple.
Feedforward Control, Constraint Overrides,
Model-Based Control, Inferential ControlPitops is not only a
transfer function
identifier and PID
tuning optimizer
but has the
functions to design,
implement and
tune Feedforwards,
Constraint Control
Schemes, Model-
Based Control and
Inferential Control
Schemes.
Feedforward
ControlProduction Rate Maximizing APC
Constraint
Override
Control
Inferential
and Model-
Based
Control
Advanced Process Control (APC) in DCS/PLCPitops has all
functions needed to
design DCS or PLC
resident APC
(advanced process
control) in a novel
and convenient
manner, far superior
to current
technologies.
In many cases,
performance of a
Pitops-based
DCS/PLC APC can
be superior to an
MPC.
PITOPS is a Comprehensive Industrial
Process Control Solutions Pitops works with any DCS or PLC brand, vendor or model.
Pitops can be applied to super-fast dynamics like compressors and turbines at millisecond scan rates.
Pitops works with all PID loops like Flow Control, Pressure Control, Level Control and Temperature Control, etc.
Pitops works with super-slow PID loops like Online Analyzer Controllers scanning in minutes and with very slow settling times of over 5 hours.
Pitops calculates Control Valve Stiction during Identification and includes Stiction during PID Optimization.
Pitops can be used on Nonlinear Processes.
Pitops includes PID Output Rate of Change as an explicit constraint during PID Optimization, a unique function unmatched by competitors.
Pitops supports Gap Action and Deadband on PID simulation and optimization.
PITOPS Unique Functions
Works entirely in the simpler time domain (no need for Laplace and Z-domain knowledge). Other products use Laplace, Poles/Zeros.
Works with super-fast dynamics like compressors and turbines in milliseconds.
Works with super-slow PID loops like Online Analyzer Controllers scanning in minutes and with very slow settling times of over 5 hours.
Works with highly oscillatory data in closed-loop Auto/Cascade Modes.
Identifies transfer functions even if data has large noise and unmeasured disturbances.
Identifies Control Valve Stiction; includes stiction during PID tuning optimization.
Works on MIMO (multiple input/multiple output) systems, multiple cascades, multiple masters going to a selector and also Fan-Out PID systems.
Requires far less data (1/5th or less) compared to competitor products.
Can be used on Nonlinear Processes for Gain Scheduling/Adaptive Control.
Includes PID Output Rate of Change as an explicit constraint during PID Optimization, a unique function unmatched by competitors.
Supports Gap Action and Deadband on PID simulation and optimization.
Optimizes tuning based on SP change + Disturbances + Noise as exactly seen and encountered in DCS/PLC – unmatched by competition.
Takes 5 minutes to install, 2 hours to learn. User manual less than 60 pages!
Allows changing transfer function & PID tuning parameters to simulate what-if cases.
Contact Yazzoom Today
Yazzoom
Sales & Technical Support
Yazzoom provides technical
consulting for all your PID,
Primary Control and
Advanced Control Problems
HQ: Ghent, Belgium
www.yazzoom.com
T/F: +32 53 39 77 10