Portable Industrial Air Conditioners(800) 836-7432 • Temp-Cool.com
MANUFACTUREDIN THE USA
Since 1965, TEMP-AIR has been America’s leading provider of temporary, portable heating, cooling, dehumidifying, and air filtration services. We proudly manufacture our equipment at our corporate headquarters in Burnsville, MN.
Temp-Cool.com
Available in air-cooled, water-cooled, and heat pump varieties with sizes ranging from 1-6 tons, these units will provide the solution to any cooling need! All units fit through a 36-inch wide door and have a full line of optional accessories to fit any installation application. The LED programmable digital display is easy to read and makes your temperature adjustments as simple as possible. TEMP-COOL cools quietly at office-acceptable sound levels without significantly adding to background noise. All units are constructed of powder-coated steel thus are designed to withstand rugged environments. All TEMP-COOL purchases include a 3 year warranty (see registration card for details).
APPLICATIONS:
Conferences/Events
Data Centers
IndustrialSettings
Offices
HIGHLIGHTS:
PRODUCT OVERVIEWPRODUCT OVERVIEW
Other applications include: construction, special events, production processes, hospitals, warehouses, laboratories, manufacturing centers, schools, air hangars, supplemental or emergency air conditioning, and more!
Plug Configurations
G
XW
Y
GGG
XW
G
5-15P 6-20P 6-30P 14-60P6-50POPTIONAL ACCESSORIES
Condensate pump kit automatically removes evaporator-coil condensation allowing continuous unit operation.
Snap in Accessoriesfor easy removal
EvaporatorAir Intake
Backward-InclinedFansimprove air flowand reduce noise
Condensate Tankdrawer slide access,float switch, and double handles
Cooled Air
Recessed Storageprotects cord
Service Accesseasy access to electrical service components
Smaller Footprinttakes up less floor space than other industrial portable air conditioners
Condenser Air Intake
Exhaust
Temp-Cool.comTEMP-COOL FEATURES
Nozzle kit optimizes the ability to direct cool air precisely where needed.
Ceiling discharge kit allows condenser-air to be vented to the plenum area above a suspended ceiling.
Condenser return-air plenum allows supply-air to be ducted to the condenser coil.
Evaporator return-air plenum allows supply-air to be ducted to the evaporator coil.
Supply-duct adapter allows user to connect ductwork to unit’s cold-air discharge.
Temp-Cool.comAIR COOLEDAIR COOLED
SPECIFICATIONS
OPTIONAL ACCESSORIES
TC-18B TC-24B TC-36B TC-60B TC-60B3 TC-60B429,600
208-230/1/60/20
Digital
TX Valve
3,100
13.5
20
---
6-20P
750
1,000
0.10
40
5 gal. tank
15
65-105
63
80
33x26x47
337/375
41,000
208-230/1/60/30
Digital
TX Valve
4,500
19.7
30
---
6-30P
1,200
1,500
0.10
40
5 gal. tank
15
65-105
67
70
30x28x51
336/395
75,900
208-230/1/60/60
Digital
TX Valve
7,700
33.3
60
80
Wired
2,300
3,900
0.50
40
Pump
15
65-110
71
136
47x31x64
713/775
75,900
208-230/3/60/40
Digital
TX Valve
8,500
21.4
40
50
Wired
2,300
3,900
0.50
40
Pump
15
65-110
71
136
47x31x64
713/775
NK-2 (6”)
CK-3 (14”)
PC-2
CP-36B (14”)
EP-36B (14”)
DA-10
---
NK-3 (8”)
CK-4 (20”)
Included
CP-4B (20”)
EP-4B (20”)
DA-14
CD-60
NK-3 (8”)
CK-4 (20”)
Included
CP-4B (20”)
EP-4B (20”)
DA-14
---
1. Rating Conditions: 95° F at 60% RH.
2. Electrical ratings based on UL 484.
All specifications are subject to change without notice.
NK-2 (6”)
CK-3 (14”)
PC-2
CP-24B (14”)
EP-24B (14”)
DA-10
---
17,300
115/1/60/15
Digital
TX Valve
1,400
12.0
15
---
5-15P
550
1,000
0.10
40
5 gal. tank
15
65-110
61
80
28x23x47
221/279
Nozzle Kit
Ceiling Discharge Kit
Condensate Pump
Condenser Return - Air Plenum
Evaporator Return - Air Plenum
Cold-Air Supply Duct Adapter
14-60P Plug Kit w/ 6’ Cord
NK-2 (6”)
CK-3 (14”)
PC-1
CP-2B (14”)
EP-2B (14”)
DA-10
---
Cooling Capacity, BTU/hr1
Power Supply2 Volts/Ph/Hz/Amps
Thermostat Control
Metering Device
Power Consumption - Cooling, Watts
Current Consumption - Cooling, Amps
Minimum Circuit Amps
Max. Overcurrent Protect. Device, Amps
NEMA Plug Type
Evaporator CFM, Free Discharge
Condenser CFM
Maximum ESP, InWC
Maximum Duct Length, ft.
Condensate Removal
Condensate Pump Head, ft.
Operation Limits, (min-max) ˚F
Sound Level, dB
R-410-A Charge, oz.
LxWxH, in.
Weight, net wt/shipping wt, lb.
75,900
460/3/60/20
Digital
TX Valve
10,000
11.4
20
25
Wired
2,300
3,900
0.50
40
Pump
15
65-110
71
136
47x31x64
713/775
NK-3 (8”)
CK-4 (20”)
Included
CP-4B (20”)
EP-4B (20”)
DA-14
---
Bonus: This Equipment Series Can Also Be Used As A Dehumidifier!
WATER COOLEDWATER COOLED
SPECIFICATIONS
1. Rating Conditions: 80˚F DB/67˚F WB return air or 85˚F EWT to 95˚F LWT (3GPM/Ton) high fan speed.
2. Electrical ratings based on UL 484.
3. Other power supply options available.
50 Hz MODELS AVAILABLE - CONSULT FACTORY
All specifications are subject to change without notice.
OPTIONAL ACCESSORIES
SPECIFICATIONS TC-12W TC-18W TC-24W TC-36W21 TC-60W2123,950
208-230/1/60/20
9.9
20
6-20P
810
1.55
6.00
0.20
20
60
16
13x24x38
160/180
HK-1W
HK-2W
HK-5W
NK-2W
EP-12W
DA-10W
36,100
208-230/1/60/203
12.0
20
6-20P
1,310
2.20
9.00
0.40
20
62
24
16x28x47
240/270
HK-3W
HK-4W
HK-6W
NK-2W
EP-16W
DA-16W
60,100
208-230/1/60/303
23.7
30
6-30P
1,950
5.50
15.00
0.40
20
69
52
39x28x52
460/500
HK-3W
HK-4W
HK-6W
NK-3W
EP-16W
DA-16W
Cooling Capacity, BTU/hr1
Power Supply2
Volts/Phase/Hertz/Amps
Unit Amps
Recommended Circuit Amps
NEMA Plug Type
Evaporator CFM, Free Discharge
Condenser Water Flow, GPM 60˚F Inlet
Condenser Water Flow, GPM 85˚F Inlet
Condenser Coil Pressure Drop, PSI
Condensate Pump Head, ft.
Sound Level, dB
R-410-A Charge, oz.
LxWxH, in.
Weight, net wt/shipping wt, lb.
12,000
115/1/60/15
8.1
15
5-15P
400
0.75
3.00
0.40
20
52
14
13x20x32
110/130
18,000
115/1/60/15
11.3
15
5-15P
600
1.10
4.50
0.40
20
57
18
13x24x38
150/170
HK-1W
HK-2W
HK-5W
NK-2W
EP-12W
DA-10W
10’ Hose Kit
20’ Hose Kit
40’ Hose Kit
Nozzle Kit
Evaporator Return Air Plenum
Cold Air Supply Duct Adapter
HK-1W
HK-2W
HK-5W
NK-1W
EP-10W
DA-6W
Temp-Cool.com
HEAT PUMPSHEAT PUMPS
SPECIFICATIONS TC-12HP TC-18HP TC-24HP TC-3612HP TC-6021HP
24,020
24,020
208-230/1/60/20
14.9
20
6-20P
810
1,010
20
65
37
30x24x45
260/285
36,050
32,500
208-230/1/60/304
18.1
30
6-30P
1,310
1,390
20
69
66
35x28x49
365/405
60,050
53,500
208-230/1/60/504
32.0
50
6-50P
1,950
2,200
20
78
80
39x28x52
485/525
Cooling Capacity, BTU/hr1
Heating Capacity, BTU/hr2
Power Supply3
Volts/Phase/Hertz/Amps
Cooling Amps
Recommended Circuit Amps
NEMA Plug Type
Evaporator CFM
Condenser CFM
Condensate Pump Head, ft.
Sound Level, dB
R-410-A Charge, oz.
LxWxH, in.
Weight, net wt/shipping wt, lb.
11,800
11,000
115/1/60/15
10.4
15
5-15P
400
580
20
54
18
25x20x37
180/200
16,800
15,600
115/1/60/20
14.1
20
5-20P
600
930
20
60
40
30x24x45
260/285
1. Cooling Capacity Rating Conditions: 80˚F DB/67˚F WB return air, 95˚F outdoor high fan speed.
2. Heating Capacity Rating Conditions: 70˚F DB/60˚F WB indoor, 47˚F DB/43˚F WB outdoor high fan speed.
3. Electrical ratings based on UL 484.
4. Other power supply options are available.
50 Hz MODELS AVAILABLE - CONSULT FACTORY
All specifications are subject to change without notice.
OPTIONAL ACCESSORIES DF-OH12
CK-OH12
NK-OH2
EP-OH12
CP-OH2
PC-OH2
DA-OH10
DF-OH12
CK-OH12
NK-OH2
EP-OH16
CP-OH3
PC-OH2
DA-OH10
DF-OH16
CK-OH16
NK-OH3
EP-OH16
CP-OH4
Standard
DA-OH16
DF-OH12
CK-OH12
NK-OH2
EP-OH12
CP-OH2
PC-OH1
DA-OH10
DF-OH12
CK-OH12
NK-OH1
EP-OH10
CP-OH1
PC-OH1
DA-OH6
Duct Flange
Ceiling Discharge Kit
Nozzle Kit
Evaporator Return Air Plenum
Condenser Return Air Plenum
Condensate Pump
Duct Adapter
Temp-Cool.com
TC-CAT-1
FSC logo
TEMP-COOL Products Are Available NationwideThrough Our Wide Range Of Distributors
Toll-Free: (800) 836-7432www.Temp-Cool.com
Our TEMP-COOL Branch Offices