Portex® Blue Line Ultra® Tracheostomy Tubes
EASY INSERTION AND COMFORT
Blue Line Ultra® Tracheostomy Tubes
EASY INSERTION AND COMFORT
TR194415EN.indd 1 21-12-11 12:33
Suctionaid® facilitates safe and comfortable
SUCTION ABOVE THE CUFF of sub-glottic secretion as
recommended by CDC*
* Guidelines for Preventing Heath-Care-Associated Pneumonia,2003, Recommendations of CDC and the Healthcare InfectionControl Practices Advisory Committee. (II) (44,134-137).
Portex® Blue Line Ultra® Suctionaid® Tracheostomy TubesEach Suctionaid® tube is equipped with an additional lumen to permit effective removal of secretions above the cuff, minimizing the risk of aspiration. The suction lumen can be used to apply continuous or intermittent suction (thumb valve included) above the cuff. Change kits include a J-tip guidewire to help ensure the correct placement of the replacement tube.
Portex® Blue Line Ultra® Tracheostomy TubesThe Blue Line Ultra® Tracheostomy Tube is your one tube solution. Tubes are available separately for surgical placement or included in percutaneous tracheotomy kits and can be used for both inpatients and outpatients. Additionally, the tubes are packaged with two inner cannulas, which are reusable. Simplify and standardize.
Comfortable • Thermosensitive material, with sufficient initial rigidity for insertion,
conforms to the individual patient’s upper respiratory tract at body temperature
• Clear, anatomically-shaped flange provides better access for stoma care• Smooth inner cannula resists secretion adherence and reduces the
tube’s inner diameter by only 1mm, producing minimal airway resistance• 15 mm connector is bonded to the tube, allowing attachment of a
ventilator breathing circuit even when an inner cannula is not present
Easy to insert • Arc is tapered anteriorly to keep distal
tip midline• Tapered tip eases placement • Hollow obturator with retaining clips
and hemispherical tip aid tube insertion• Soft-Seal® cuff with low profile and
smooth transition to the tube eases insertion
Why choose Portex® Blue Line Ultra® Tracheostomy Tubes:
TR194415EN.indd 2 21-12-11 12:33
100/817/080
Blue Line Ultra® Cuffed Fenestrated Tracheostomy TubesPRODUCT TUBE TUBE TUBE TUBE UNITS CODE SIZE I.D. O.D. LENGTH PER CASE
100/817/060 6.0 mm 6.0 mm 9.2 mm 64.5 mm 1
100/817/070 7.0 mm 7.0 mm 10.5 mm 70.0 mm 1
100/817/080 8.0 mm 8.0 mm 11.9 mm 75.5 mm 1
100/817/090 9.0 mm 9.0 mm 13.3 mm 81.0 mm 1
100/817/100 10.0 mm 10.0 mm 14.0 mm 87.5 mm 1Includes inner cannula with stop ring, disconnection wedge, tracheostomy tube holder, cleaning brush, and patient label.
100/815/080
Blue Line Ultra® Cuffed Tracheostomy TubesPRODUCT TUBE TUBE TUBE TUBE UNITS CODE SIZE I.D. O.D. LENGTH PER CASE
100/815/060 6.0 mm 6.0 mm 9.2 mm 64.5 mm 1
100/815/070 7.0 mm 7.0 mm 10.5 mm 70.0 mm 1
100/815/075 7.5 mm 7.5 mm 11.3 mm 73.0 mm 1
100/815/080 8.0 mm 8.0 mm 11.9 mm 75.5 mm 1
100/815/085 8.5 mm 8.5 mm 12.6 mm 78.0 mm 1
100/815/090 9.0 mm 9.0 mm 13.3 mm 81.0 mm 1
100/815/100 10.0 mm 10.0 mm 14.0 mm 87.5 mm 1Includes inner cannula with stop ring, disconnection wedge, tracheostomy tube holder, cleaning brush, and patient label.
100/816/080
Blue Line Ultra® Uncuffed Tracheostomy TubesPRODUCT TUBE TUBE TUBE TUBE UNITS CODE SIZE I.D. O.D. LENGTH PER CASE
100/816/060 6.0 mm 6.0 mm 9.2 mm 64.5 mm 1
100/816/070 7.0 mm 7.0 mm 10.5 mm 70.0 mm 1
100/816/075 7.5 mm 7.5 mm 11.3 mm 73.0 mm 1
100/816/080 8.0 mm 8.0 mm 11.9 mm 75.5 mm 1
100/816/085 8.5 mm 8.5 mm 12.6 mm 78.0 mm 1
100/816/090 9.0 mm 9.0 mm 13.3 mm 81.0 mm 1
100/816/100 10.0 mm 10.0 mm 14.0 mm 87.5 mm 1Includes inner cannula with stop ring, disconnection wedge, tracheostomy tube holder, cleaning brush, and patient label.
100/818/080
Blue Line Ultra® Uncuffed Fenestrated Tracheostomy TubesPRODUCT TUBE TUBE TUBE TUBE UNITSCODE SIZE I.D. O.D. LENGTH PER CASE
100/818/060 6.0 mm 6.0 mm 9.2 mm 64.5 mm 1
100/818/070 7.0 mm 7.0 mm 10.5 mm 70.0 mm 1
100/818/080 8.0 mm 8.0 mm 11.9 mm 75.5 mm 1
100/818/090 9.0 mm 9.0 mm 13.3 mm 81.0 mm 1
100/818/100 10.0 mm 10.0 mm 14.0 mm 87.5 mm 1Includes inner cannula with stop ring, disconnection wedge, tracheostomy tube holder, cleaning brush, and patient label.
100/875/080
Blue Line Ultra® Suctionaid® Tracheostomy TubesPRODUCT TUBE TUBE TUBE TUBE UNITS CODE SIZE I.D. O.D. LENGTH PER CASE
100/875/060 6.0 mm 6.0 mm 9.2 mm 64.5 mm 1
100/875/070 7.0 mm 7.0 mm 10.5 mm 70.0 mm 1
100/875/075 7.5 mm 7.5 mm 11.3 mm 73.0 mm 1
100/875/080 8.0 mm 8.0 mm 11.9 mm 75.5 mm 1
100/875/085 8.5 mm 8.5 mm 12.6 mm 78.0 mm 1
100/875/090 9.0 mm 9.0 mm 13.3 mm 81.0 mm 1
100/875/100 10.0 mm 10.0 mm 14.0 mm 87.5 mm 1
Includes inner cannula with stop ring, disconnection wedge, tracheostomy tube holder, cleaning brush, and patient label.
TR194415EN.indd 3 21-12-11 12:33
Smiths Medical International LtdHythe, Kent CT21 6JL UKTel: +44 (0)1303 260551 Fax: +44 (0)1303 266761www.smiths-medical.com
Smiths Medical ASD, Inc.Norwell, MA 02061, USAPhone: 1-214-618-0218 Toll-Free USA: 1-800-258-5361
THE DETAILS GIVEN IN THIS LEAFLET ARE CORRECT AT THE TIME OF GOING TO PRESS. THE COMPANY RESERVES THE RIGHT TO IMPROVE THE EQUIPMENT SHOWN.
The Portex and Smiths Medical design marks, Blue Line, Blue Line Ultra, Suctionaid, Soft-Seal, D.I.C., Bivona and UniPerc are trademarks of Smiths Medical. The symbol ® indicates that the trademark is registered in the U.S. Patent and Trademark Office and certain other countries. All other names and marks mentioned are trade names, trademarks, and service marks of their respective owners.©2011 Smiths Medical family. All rights reserved. TR194415EN 01.2011
Product(s) described may not be licensed or available for sale in Canada or other countries outside of the United States.
Smiths Medical Canada Ltd.Markham, Ontario, Canada, L3R 4Y8Phone: 905-477-2000Toll-Free: 1-800-387-4346
www.smiths-medical.comSmiths Medical is part of the global technology business Smiths Group plc.
100/856/080
Inner Cannula for Blue Line Ultra® Tracheostomy TubesPRODUCT INNER UNITS CODE DESCRIPTION CANNULA I.D. PER CASE
100/856/060 Inner Cannula for 6.0 mm Tube 5.0 mm 20
100/856/070 Inner Cannula for 7.0 mm Tube 6.0 mm 20
100/856/075 Inner Cannula for 7.5 mm Tube 6.5 mm 20
100/856/080 Inner Cannula for 8.0 mm Tube 7.0 mm 20
100/856/085 Inner Cannula for 8.5 mm Tube 7.5 mm 20
100/856/090 Inner Cannula for 9.0 mm Tube 8.0 mm 20
100/856/100 Inner cannula for 10.0 mm tube 8.5 mm 20
100/858/060 Inner Cannula for 6.0 mm Tube 5.0 mm 50
100/858/070 Inner Cannula for 7.0 mm Tube 6.0 mm 50
100/858/075 Inner Cannula for 7.5 mm Tube 6.5 mm 50
100/858/080 Inner Cannula for 8.0 mm Tube 7.0 mm 50
100/858/085 Inner Cannula for 8.5 mm Tube 7.5 mm 50
100/858/090 Inner Cannula for 9.0 mm Tube 8.0 mm 50
100/858/100 Inner Cannula for 10.0 mm Tube 8.5 mm 50
Ordering instructions:
Signature: ___________________________________________________
Date: _______________________________________________________
Name: ______________________________________________________
Please add the Portex® Blue Line Ultra® Tracheostomy Tubes to my preference card.Please add the Portex® Blue Line® Tracheostomy Tubes to my preference card.
TR194415EN.indd 4 21-12-11 12:33