2G FLEXI EDGE COMMISSIONING and INTEGRATIONBy Dexter
CONTENTS:
Commissioning Preparation
Manual CommissioningEasy Wizard Template CommissioningEasy Wizard Complete SCF CommissioningFIFA and Flexihopper CommissioningVerification of Commissioning ReportIntegrationOn-site Commissioning/Integration Procedure APPENDIX
i. Commissioning Preparation
Laptop with Nokia SoftwareChanging PC LAN settingsIP Address:192.168.255.130Subnet Mask: 255.255.255.128Default Gateway:192.168.255.129DocumentsRNP ReportParameter Entry Sheets (PES)Microwave Link Plan (MWLP)Nokia FlexiEDGE BTS manual2G FlexiEDGE BTS TI Handbook
NOTES on FlexiEDGE BTS Manager and BTS Software:
FlexiEDGE BTS Manager EP3.0 MP 2.0FlexiHub Manager 2.0 or 3.0
FlexiBTS Software: EP 2.0 CD 1.0FIFA Software: FIFA 1.2 CD 1.0
Check Installation all details according to equipment installation standard and customer standardCoordinate with OSS during the whole commissioning and integration activity6.Commissioning and integration activity shall be done by certified partners with PTID.
I. Manual Commissioning
Connect to BTSGo to Commissioning WizardChoose commission manuallyIn Site Specific Information, enter all applicable site detailsBCF ID = BSC ID = Site ID = Site Name = Location = Climate Control Profile = Ambient Air Temperature Offset = Installation Date= Installed By = Notes = In
4. Hardware Configuration:Choose specify manually
5. In Cabling Configuration:In Antenna Cabling:Set RF source unitSet RF source portSet Antenna IDIn RF Cabling:Set CablingSet Source UnitSet Source PortSet Destination UnitSet Destination Port
6. In Antenna Settings:Set Antenna Product TypeSet Antenna Serial NumberSet VSWR limits = default settings7.In Battery Back-up Unit:Input: NON_Nokia8.In Other Passive Units:Set Unit Name, Serial No., DescriptionIf using Flexi casing EMHA or EMTA: Description =
9. In Abis Protection for IF: No Settings10. In Cross Connections:Add cross connections (if applicable)In Q1 Management:Add Q1 EOC Allocation (if applicable)Save and ExitFormat: SITENAME_Configuration.ept
13. In Abis Termination:No Settings14. In Current Abis Allocations:Set OMUSIG = according to PESSet TCH = according to PESSet TRXSIG = according to PESSet EDAP = according to PES15. In Abis Protection for IF: No Settings16. In Cross Connections:Add cross connections (if applicable)17. In Q1 Management:Add Q1 EOC Allocation (if applicable)
18.Click send SCF file19.View commissioning progress and commissioning result20.Save Commissioning ReportFormat: SITENAME_Configuration_Comreport.txt
II. EasyWizard Template Commissioning
Creating EasyWizard hardware template (*.epb)Go to Commissioning WizardChoose: create EasyWizard hardware template fileIn Hardware Configuration: choose specify manuallyIn Cabling Configuration:In Antenna Cabling:Set RF source unitSet RF source portSet Antenna ID
b. In RF Cabling:Set CablingSet Source UnitSet Source PortSet Destination UnitSet Destination Port5. In Antenna Settings:Set Antenna Product TypeSet Antenna Serial NumberSet VSWR limits = default settings
In Battery Back-up Unit:Input: NON-NokiaIn Other Passive Units:Set Unit Name, Serial No., DescriptionIf using Flexi casing EMHA or EMTA: Description = Save and ExitFormat: SITENAME_Configuration.epb
B. Creating EasyWizard transmission template (*.ept)Go to Commissioning WizardChoose: create EasyWizard transmission template fileIn Transmission Parameters, choose specify manuallySelect TRS PIU Type = (8E1/T1), orSelect TRS PIU Type = (16 E1 radio)In Line Interface Settings:Interface in UseInterface Name = CRC in Use = clicked checkIn Synchronization:Priority 1 = RX Clock IF E1/T1 XPriority 2 = Internal Timing
6. In Synch Protection:Topology = Chain7. In Abis Termination:No Setting8. In Current Abis Allocations:Set OMUSIG = according to PESSet TCH = according to PESSet TRXSIG= according to PESSet EDAP = according to PES
9. In Abis Protection for IF: No Settings10. In Cross Connections:Add cross connections (if applicable)In Q1 Management:Add Q1 EOC Allocation (if applicable) Save and ExitFormat: SITENAME_Configuration.ept
C. Commissioning FlexiEDGE BTS with Easy Wizard TemplatesConnect to BTSGo to Commissioning WizardChoose change settings from Easy Wizard template fileBrowse, select and enter hardware template fileBrowse, select and enter transmission template file
3. In Site Specific Information, enter all applicable site detailsBCF ID = BSC ID = Site ID = Site Name = Location = Climate Control Profile = Ambient Air Temperature Offset = Installation Date= Installed By = Notes =
4. In Antenna Settings:Set Antenna Product TypeSet Antenna Serial NumberSet VSWR limits = default settingsIn Battery Back-up Unit:Input: NON-Nokia6. In Other Passive Units:Set Unit Name, Serial No., DescriptionIf using Flexi casing EMHA or EMTA: Description = Click send SCFView commissioning progress and commissioning resultSave Commissioning ReportFormat: SITENAME_Configuration_Comreport.txt
III. EasyWizard Complete SCF Commissioning
A. Creating an SCF fileGo to Commissioning WizardChoose create SCF, and tick complete SCFIn Site Specific Information, enter all applicable site detailsBCF ID = BSC ID = Site ID = Site Name = Location = Climate Control Profile = Ambient Air Temperature Offset = Installation Date= Installed By = Notes =
3. In Hardware Configuration:Choose specify manually 4. In Cabling Configuration:In Antenna Cabling:Set RF source unitSet RF source portSet Antenna IDIn RF Cabling:Set CablingSet Source UnitSet Source PortSet Destination UnitSet Destination Port
5. In Antenna Settings:Set Antenna Product TypeSet Antenna Serial NumberSet VSWR limits = default settingsIn Battery Back-up Unit:Input: NON-NokiaIn Other Passive Units:Set Unit Name, Serial No., DescriptionIf using Flexi casing EMHA or EMTA: Serial No =
8. In Transmission Parameters, choose specify manuallySelect TRS PIU Type = (8E1/T1), orSelect TRS PIU Type = (16 E1 radio)9. In Line Interface Settings:Interface in UseInterface Name = CRC in Use = clicked check10. In Synchronization:Priority 1 = RX Clock IF E1/T1 XPriority 2 = Internal Timing11. In Synch Protection:Topology = Chain
12. In Abis Termination:No Settings13. In Current Abis Allocations:Set OMUSIG = according to PESSet TCH = according to PESSet TRXSIG = according to PESSet EDAP = according to PES14. In Abis Protection for IF: No Settings15. In Cross Connections:Add cross connections (if applicable)16. In Q1 Management:Add Q1 EOC Allocation (if applicable)17. Save and ExitFormat: SITENAME_Configuration.xml
B. Commissioning FlexiEDGE BTS with SCF fileConnect to BTSGo to Commissioning WizardChoose commission from SCFBrowse, select and enter SCF fileClick send SCF fileView commissioning progress and commissioning resultSave Commissioning ReportFormat: SITENAME_Configuration_Comreport.txt
IV. Commissioning FIFA and Flexihopper
Open FlexiEDGE BTS Manager and connect to BTSOpen FlexiHub Manager From FlexiEDGE BTS Manager, go to Transmission, Launch Flexihub ManagerGo to Programs -> Nokia -> Nokia -> FlexiHub ManagerGo to Commissioning to start the Commissioning WizardIn Start Page, select the network element and radio hop/s to be commissionedTick - Network ElementTick - Single Hop 1(FB1)Click the Configure Hardware button to start hardware scanningIn Site Identifications page, enter all the necessary site information detailsEquipment Name= Group Name= Site Name= Site Location= Installer= Installation Date= Installation Time= Notes=
In DCN Remote Management page, fill in Q1 management information for remote network managementTick Use BTS PollingQ1 Port Speed = Q1 Port Address = Tick Q1 to ProcessorNO TICK Q1 to Flexbus Master SwitchNO TICK Q1 to Flexbus 1NO TICK Q1 to Flexbus 2 In Time Management page, set the real time clock settingsTick Set Local Time in Network Element from PC TimeIn OU-1 Alignment page, configure the outdoor unit settings Flexbus/Outdoor= Unit Capacity Tx Frequency = Maximum Tx Power = Modulation = Tx Power = tickedClick Apply and perform antenna pointing until RxL = RxL MWLP
In OU-1 Radio Hop page, enter all the Radio Interface PropertiesUnit Name = Installer= Notes = In OU-1 Radio Hop page, enter all the Radio Interface ConfigurationFlexbus/Outdoor= Unit Capacity Tx Frequency = Maximum Tx Power = Interleaver= Telkomsel settingScrambler= Modulation = In Send Parameters page, check that all configured parameters is correctClick Send ParametersIn Hop Status page, check the current hop statusHop Status= Hop working, and with no errorsRX Level = RX Level MWLP +/- 3dBmIn Commissioning Report page:Click Save to File to save the final commissioning report15.Click - Finish
Add cross-connectionSelect first connection pointSelect second connection pointClick SendClick on the new cross-connection and rename to Monitor the hopReset the statistics and counters and let the hop operate for a minimum of 30 minutesBER counters = 0RxL is stable
V. Verification of Commissioning Report
Tx Power47dBm +/- 4dB
BER (Bit Error Ratio)RF Part: FAIL if BER > 2%BB Part:FAIL if BER > 0%
VI. Integration
Perform test calls (see test call procedure)
2. Test external alarms
Save Files Commissioning Report: SITENAME_Configuration_Comreport.txtSite Information Report: SITENAME_Configuration_SiteInformationReport.txt
4. BTS with no alarms for 2 hours
Partner Excellence CenterProject Support Center, Indonesia
Field Test with Nokia Phones
Test Call Procedure
Partner Excellence CenterProject Support Center, Indonesia
Instruction:
Open Field Test Menu
Choose Options, select >Change display
Partner Excellence CenterProject Support Center, Indonesia
Instruction:
Enter number: 0 1 1 2
Partner Excellence CenterProject Support Center, Indonesia
Instruction:
Choose Options, select >Execute
Enter the ARFCN of the BCCH TRX in hexadecimal format
Partner Excellence CenterProject Support Center, Indonesia
ARFCN Absolute Radio Frequency Channel Number
PARAMETER ENTRY GSM 900hVALID UNTIL
PANYIRAPANMG1Folder NameClass Area
2BDG_MG_SUB 911E
3
Note :This PES is valid for 3 weeks, if expired contact Ica. For ABIS and ET Info questions, contact Agus & Eko.
SITE INFOABIS ALLOCATIONFH PARAMETERS
Site NamePANYIRAPANMG1234BTS is Hopping
Search RingSoreang B ex Tangkubanprh CikoleTSLTXSIGTRX#TSLTXSIGTRX#TSLTXSIGTRX#TSLTXSIGTRX#Hopping Mode
Site IDBDG461Sector 11-2(25-0)13-4(25-4)25-6(26-0)3Used MA Assigned
Site TypeUltrasiteSector 29-10(27-0)511-12(27-4)6HSN-1
CELL PARAMETERSSector 317-18(29-0)919-20(29-4)1021-22(30-0)11HSN-2
S 1PANYIRAPANMG1Sector 4MAL ID
S 2PANYIRAPANMG2Sector 5MAIO Offset
S 3PANYIRAPANMG3Sector 6MAIO Step
S 1S 2S 3OMU SIG31-0Remarks:Ultrasite 3/2/3 GSM Soreang BDUAL BAND PARAMETERS
Cell ID563115631256313ET#54TRXSIG 32kbps, OMUSIG 16kbpsMultiband Cell Reporting
Azimuth120210300# of CAB1Early Sending Indication
Cell Type900-Macro900-Macro900-MacroDual Band Cell
---MSC INFOGPRS PARAMS1S2S2C2 PARAMETERS
Configuration323MSC NameMBDG5GTUGT555Parameter Index
BCCH526356BSC NameDAYEUH KOLOT 2DK2GENAYYYCell Barred Qual
Initial Freq 2707682SPC MSC2105CDED1%1%1%Cell Reselect Offset
Initial Freq 372n/a84SPC BSC2147CDEF31%31%31%Temporary Offset
Initial Freq 4n/an/an/aLOCNO311BFGNNNPenalty Time
LAC230230230POCBandungALPHA777BTS PARAMETERS
NCC222MISCELLENEOUS INFOGAMMA323232Ms Tx Power Min
BCC777LONGITUDEE 107 31' 28TRP222Ms Tx Power Max CCH
BCF #60LATTITUDES 7 2' 16.6GTRX222Rx Lev Access Min
BTS #173174175ADDRESSKp Panyirapan Ds Panyirapan Kec Soreang Kab BandungRAC230230230Rx Diversity
SDCCH #323Max BTS TX Power
Electrical Tilt206
Mechanical Tilt000
CollocatedNNN
S 1S 2S 3
Cell ID563115631256313
Azimuth120210300
Cell Type900-Macro900-Macro900-Macro
---
Configuration323
BCCH526356
Partner Excellence CenterProject Support Center, Indonesia
Sample conversion: Convert 541 to hexadecimal
Step 1 16 541 33 r 13
Step 2 16 33 2 r 1
Step 3 16 2 0 r 2
Remember to keep dividing until this digit is 0
541 = 2 1 D
HEXADECIMAL0123456789ABCDEF
DECIMAL0123456789101112131415
Partner Excellence CenterProject Support Center, Indonesia
Instruction:
Choose Options, select >Change display
Enter number: 0 1 0 1
0101
Partner Excellence CenterProject Support Center, Indonesia
Instruction:
Make a call while the Field Test view is active
Partner Excellence CenterProject Support Center, Indonesia
Instruction:
After the call set up, open the Field Test menu again
In the Field Test info view, TS indicates the timeslot that is currently occupied by the call.
Partner Excellence CenterProject Support Center, Indonesia
Instruction:
Open Field Test Menu
Choose Options, select >Change display
Setting the phone back to normal mode:
Partner Excellence CenterProject Support Center, Indonesia
Instruction:
Enter number: 0 1 1 2
Partner Excellence CenterProject Support Center, Indonesia
Instruction:
Choose Options, select >Execute
Enter the value: F F F
FFF
Partner Excellence CenterProject Support Center, Indonesia
Instruction:
When the BTS TEST shows, OFF, the phone is already back to normal mode.
*
*
*
*
*
*
*
*
*
*
*
*
*
VII. On-site Commissioning/Integration Procedure
Check InstallationPower on FlexiEDGE BTSConnect to BTSConfigure Log File settingsUpgrade BTS softwareLaunch Flexihub Manager and connect to FIFACommission FIFAUpgrade FIFA softwareCommission FlexiEDGE BTSPerform TRX testPerform Test callsPerform External Alarms testCheck Q1 remote connectionSave files for site documentation
APPENDIX
Fill on BCF-ID, data based on PES (this is must be filled/mandatory filled) Fill on BSC-ID & BSC Name, info verified from NIC Fill on Site-ID & Site Name (data from PES), Location for site For this, always set to optimized cooling & normal Fill for date for installation & who was installed For Notes : fill with configuration from BTS (example BTS Flexy MD Karang Tengah 333) Thick next
Choose Specify from file, if you have an existing configuration of file (in SCF file mode) Choose Specify Manually, if you dont havea file Then, click next
Choose Specify from file, if you have an existing configuration of file (in SCF file mode) Choose Specify Manually, if you dont have a file, & select what transmission type that in use for installation Click next
For this, I use FIPA Transmission type, so I thick for maximum capacity 8 x E1 interfaces (120 ohm) Choose Specify Manually, if you dont have a file, & select what transmission type that in use for installation Click next
COMMISISONING FLEXY EDGE BTS From 8 E1, you can choose, 1 E1/ 1 interface do you need it., After that, thick for Interface in use & CRC in Use. Click next
For synchronization, always check : 1.Always for priority 1 is RF Clock 2.Priority no.2 is Internal Timing Click next
For this page, leave this page & set to default. Click next
Fill, TCH, TRX SIG, & OMUSIG .based on your configuration (for this I use config 444) Click next
Set all to default & continue to next step. !!!!
If there is new drop inserted system, you can fill in. Set all to default & continue to next step. !!!!
For Q1, set to default or leave this page & go to next step.
This is the summary all of configuration, save to fiile & send to BTS Save Commissioning Report Format: SITENAME_Configuration_Comreport.txt
V. Verification of Commissioning Report
Tx Power47dBm +/- 4dB
BER (Bit Error Ratio)RF Part: FAIL if BER > 2%BB Part:FAIL if BER > 0%
VI. Integration
Perform test calls (see test call procedure)
2. Test external alarms
Save Files Commissioning Report: SITENAME_Configuration_Comreport.txtSite Information Report: SITENAME_Configuration_SiteInformationReport.txt
4. BTS with no alarms for 2 hours
Partner Excellence CenterProject Support Center, Indonesia
Field Test with Nokia Phones
Test Call Procedure
Partner Excellence CenterProject Support Center, Indonesia
Instruction:
Open Field Test Menu
Choose Options, select >Change display
Partner Excellence CenterProject Support Center, Indonesia
Instruction:
Enter number: 0 1 1 2
Partner Excellence CenterProject Support Center, Indonesia
Instruction:
Choose Options, select >Execute
Enter the ARFCN of the BCCH TRX in hexadecimal format
Partner Excellence CenterProject Support Center, Indonesia
ARFCN Absolute Radio Frequency Channel Number
PARAMETER ENTRY GSM 900hVALID UNTIL
PANYIRAPANMG1Folder NameClass Area
2BDG_MG_SUB 911E
3
Note :This PES is valid for 3 weeks, if expired contact Ica. For ABIS and ET Info questions, contact Agus & Eko.
SITE INFOABIS ALLOCATIONFH PARAMETERS
Site NamePANYIRAPANMG1234BTS is Hopping
Search RingSoreang B ex Tangkubanprh CikoleTSLTXSIGTRX#TSLTXSIGTRX#TSLTXSIGTRX#TSLTXSIGTRX#Hopping Mode
Site IDBDG461Sector 11-2(25-0)13-4(25-4)25-6(26-0)3Used MA Assigned
Site TypeUltrasiteSector 29-10(27-0)511-12(27-4)6HSN-1
CELL PARAMETERSSector 317-18(29-0)919-20(29-4)1021-22(30-0)11HSN-2
S 1PANYIRAPANMG1Sector 4MAL ID
S 2PANYIRAPANMG2Sector 5MAIO Offset
S 3PANYIRAPANMG3Sector 6MAIO Step
S 1S 2S 3OMU SIG31-0Remarks:Ultrasite 3/2/3 GSM Soreang BDUAL BAND PARAMETERS
Cell ID563115631256313ET#54TRXSIG 32kbps, OMUSIG 16kbpsMultiband Cell Reporting
Azimuth120210300# of CAB1Early Sending Indication
Cell Type900-Macro900-Macro900-MacroDual Band Cell
---MSC INFOGPRS PARAMS1S2S2C2 PARAMETERS
Configuration323MSC NameMBDG5GTUGT555Parameter Index
BCCH526356BSC NameDAYEUH KOLOT 2DK2GENAYYYCell Barred Qual
Initial Freq 2707682SPC MSC2105CDED1%1%1%Cell Reselect Offset
Initial Freq 372n/a84SPC BSC2147CDEF31%31%31%Temporary Offset
Initial Freq 4n/an/an/aLOCNO311BFGNNNPenalty Time
LAC230230230POCBandungALPHA777BTS PARAMETERS
NCC222MISCELLENEOUS INFOGAMMA323232Ms Tx Power Min
BCC777LONGITUDEE 107 31' 28TRP222Ms Tx Power Max CCH
BCF #60LATTITUDES 7 2' 16.6GTRX222Rx Lev Access Min
BTS #173174175ADDRESSKp Panyirapan Ds Panyirapan Kec Soreang Kab BandungRAC230230230Rx Diversity
SDCCH #323Max BTS TX Power
Electrical Tilt206
Mechanical Tilt000
CollocatedNNN
S 1S 2S 3
Cell ID563115631256313
Azimuth120210300
Cell Type900-Macro900-Macro900-Macro
---
Configuration323
BCCH526356
Partner Excellence CenterProject Support Center, Indonesia
Sample conversion: Convert 541 to hexadecimal
Step 1 16 541 33 r 13
Step 2 16 33 2 r 1
Step 3 16 2 0 r 2
Remember to keep dividing until this digit is 0
541 = 2 1 D
HEXADECIMAL0123456789ABCDEF
DECIMAL0123456789101112131415
Partner Excellence CenterProject Support Center, Indonesia
Instruction:
Choose Options, select >Change display
Enter number: 0 1 0 1
0101
Partner Excellence CenterProject Support Center, Indonesia
Instruction:
Make a call while the Field Test view is active
Partner Excellence CenterProject Support Center, Indonesia
Instruction:
After the call set up, open the Field Test menu again
In the Field Test info view, TS indicates the timeslot that is currently occupied by the call.
Partner Excellence CenterProject Support Center, Indonesia
Instruction:
Open Field Test Menu
Choose Options, select >Change display
Setting the phone back to normal mode:
Partner Excellence CenterProject Support Center, Indonesia
Instruction:
Enter number: 0 1 1 2
Partner Excellence CenterProject Support Center, Indonesia
Instruction:
Choose Options, select >Execute
Enter the value: F F F
FFF
Partner Excellence CenterProject Support Center, Indonesia
Instruction:
When the BTS TEST shows, OFF, the phone is already back to normal mode.
*
*
*
*
*
*
*
*
*
*
*
*
*
SAMPLE SCREENSHOTS : FILES TO SAVED
SAMPLE SCREENSHOTS : TRX TEST
SAMPLE SCREENSHOTS : ABIS MAPPING
ACTIVATION EDGE
ACTIVATION EDGE Click Tab transmission, & choose for Abis allocation
ACTIVATION EDGE On select TRX, choose what TRX to use EDAP, if you On select signal size, choose more than one, you choose how many TS to can clik press & hold ctrl & use EDAP, example I clik for TRx number take 4 TS, from TS 21 (example, I use trx s/d 24 1,2,5,6,9,10). EDAP will show at purple colour
PROBLEM SOLVING
ALARM ACTUALLY FOUNDED ON BTS FLEXY (7607=tTrx Operation Degraded)-PROBLEM SOLVING
ALARM ACTUALLY FOUNDED ON BTS FLEXY (7604=BTS Operation Degraded)
ALARM ACTUALLY FOUNDED ON BTS FLEXY (7606=TRX Faulty)
ALARM ACTUALLY FOUNDED ON BTS FLEXY (7606=TRX Faulty)
END
********