RZ_Dia_Kurz_Kat_281008 05.11.2008 12:56 Uhr Seite 1
Probedruck
C M Y CM MY CY CMY K
d i a sys d i a g n o st i c syst e m s
09
clinical chemistry
immunoturbidimetric tests
instruments
calibrators · standards · controls · supplementary reagents
::010 ::011 ::012 ::013 ::014 ::015 ::016 ::017 ::018
::026 ::027 ::028 ::029 ::030 ::031 ::032
::036 ::037 ::038 ::039
::043 ::044 ::045
::048 ::049
::050 ::051 ::052
::056 ::037 ::058
::060 ::061 ::062 ::063 ::064
short catalogue
::065 ::066 ::067 ::068
::069 ::070
::071
RZ_Dia_Kurz_Kat_281008 05.11.2008 12:56 Uhr Seite 2
Probedruck
C M Y CM MY CY CMY K
02
welcome to the diasys short catalogue 2009
DiaSys Diagnostic Systems is a leading specialist in development and manufacturing of diagnosticsystems of high quality combined with ease of use and reduced environmental burden.
Focusing on clinical chemistry and immunoturbidimetric tests we have introduced more than80 optimized reagents for routine and special diagnostics in user-friendly kits for manual or automated use. Additionally, the programme includes a broad range of appropriate calibratorsand controls, as well as photometric systems and glucose/lactate analyzers. To date, customersand partners in more than 100 countries around the world rely on DiaSys quality.
DiaSys maintains a quality management system certified according to ISO 13485:2003/ISO 9001:2000.All our products are CE marked according to Directive 98/79/EC.
why a short catalogue?The DiaSys short catalogue 2009 wants to give a quick overview of the available reagents for clinicalchemistry and immunoturbidimetry, as well as of additional products like supplementary reagents,calibrators, controls and standards.Finally not to neglect presenting our growing portfolio of instruments headed by the clinicalchemistry analyzer RESPONS® 920 and the point-of-care diabetes analyzer InnovaStar®.
how to place your orderAs you have already noticed, there are no ordering numbers specified in the catalogue. Due to thehuge amount of different kit sizes available and systems supplied, it would go beyond the scope ofthis handout to list them all. In case you would like to order DiaSys products please refer to theDiaSys product catalogue 2009 or to the contact form on our website www.diasys-diagnostics.com.
the supplied systemsDiaSys reagents are available in dedicated kits for several analyzer systems. To give you a fastoverview a dot behind the respective reagent marks the supplied instrument line. Find additionalinformation about the instrument lines below the respective tables.
some abbreviations in common use
contents page
FS Fluid-stable, ready-to-use reagent
FSC Fluid-stable concentrated reagent for the measurement on Olympus AU systems
:: Clinical Chemistry 03
:: Immunoturbidimetric Tests 05
:: Calibrators / Standards 06
:: Controls / Supplementary Reagents / Special Products 07
:: Instruments 08
03
05
06
07
08
RZ_Dia_Kurz_Kat_281008 05.11.2008 12:56 Uhr Seite 3
Probedruck
C M Y CM MY CY CMY K
reagents
clin
ical
che
mis
try
a – g
Product
03
clinical chemistry
Method RESP
ON
S®
Mul
tiple
-pur
pose
Hita
chi 9
11
Hita
chi 9
17
Oly
mpu
s AU
Pres
tige
24i
Sele
ctra
supplied systems*
* Additional information (for precise information concerning supplied analyzer types please refer to DiaSys product catalogue 2009)Multi-purpose Kits: DiaSys reagents in kits for multi-purpose and manual use - no analyzer specific bottlesKits for Hitachi 911: Full bar code; bottles suitable for several Hitachi and Olympus analyzers, as well as for Abbott Aeroset and Merck MEGAKits for Hitachi 917: Full bar code; bottles suitable for several Hitachi, Abbott Aeroset, Olympus and Advia analyzers, as well as for Abbott Aeroset and Merck MEGA Kits for Olympus AU systems: Fully barcoded bottles; suitable for Olympus AU 600/AU 400/AU 640/AU 2700/AU 5400Kits for Selectra Systems: Bottles suitable for Vitalab Selectra
ALAT (GPT) FS (IFCC mod.) UV test according to IFCC • • • • • •ALAT (GPT) FSC (IFCC mod.) UV test according to IFCC •Albumin FS Bromocresol green method • • • • • •Albumin FSC Bromocresol green method •Alkaline phosphatase FS DGKC Test according to DGKC • • • •Alkaline phosphatase FS IFCC 37 °C Test according to IFCC • • • • • • •
-Amylase FS CNP-G3 CNP-G3 method •-Amylase CC FS EPS-G7 method according to IFCC • • • • • • •
ASAT (GOT) FS (IFCC mod.) UV test according to IFCC • • • • • •ASAT (GOT) FSC (IFCC mod.) UV test according to IFCC •ATP Hexokinase FS Enzymatic UV test using hexokinase •Bicarbonate FS Enzymatic test using NADH analogue • • • •Bile acids Colorimetric test •Bilirubin Auto Direct FS DCA method • • • • • • •Bilirubin Auto Total FS DCA method • • • • • • •Bilirubin Jendrassik-Gróf FS Colorimetric test according to Jendrassik-Gróf •Calcium AS FS Arsenazo III method • • •Calcium CPC FS o-Cresolphthalein complexone method • • • •Calcium CPC FSC o-Cresolphthalein complexone method •Calcium P FS Phosphonazo III method • • • •Chloride FS Photometric test using thiocyanate • • •Cholesterol FS 5' version CHOD-PAP method •Cholesterol FS 10' version CHOD-PAP method • • • • • •Cholesterol FSC CHOD-PAP method •Cholinesterase FS Butyrylthiocholine test according to DGKC • • • • •CK-MB FS Test according to IFCC/DGKC • • • • • •CK-NAC FS Test according to IFCC/DGKC • • • • • • •Creatinine FS Jaffé method (compensation optional) • • • • • •Creatinine FSC Jaffé method (compensation optional) •Creatinine PAP FS Enzymatic PAP method • • • • • •Ethanol FS Enzymatic UV test • • • •Free cholesterol FS CHOD-PAP method • •Free glycerol FS GPO method • •Gamma-GT FS (Szasz mod./IFCC stand.) Szasz method IFCC standardized • • • • • •
RZ_Dia_Kurz_Kat_281008 05.11.2008 12:56 Uhr Seite 4
Probedruck
C M Y CM MY CY CMY K
clinical chemistry
reagents
clin
ical
che
mis
try
g – u
04
Product Method RESP
ON
S®
Mul
tiple
-pur
pose
Hita
chi 9
11
Hita
chi 9
17
Oly
mpu
s AU
Pres
tige
24i
Sele
ctra
supplied systems*
* Additional information (for precise information concerning supplied analyzer types please refer to DiaSys product catalogue 2009)Multi-purpose Kits: DiaSys reagents in kits for multi-purpose and manual use - no analyzer specific bottlesKits for Hitachi 911: Full bar code; bottles suitable for several Hitachi and Olympus analyzers, as well as for Abbott Aeroset and Merck MEGAKits for Hitachi 917: Full bar code; bottles suitable for several Hitachi, Abbott Aeroset, Olympus and Advia analyzers, as well as for Abbott Aeroset and Merck MEGA Kits for Olympus AU systems: Fully barcoded bottles; suitable for Olympus AU 600/AU 400/AU 640/AU 2700/AU 5400Kits for Selectra Systems: Bottles suitable for Vitalab Selectra
Gamma-GT FSC (Szasz mod./IFCC stand.) Szasz method IFCC standardized •GLDH FS DGKC UV test according to DGKC • • • •Glucose Gluc-DH FS Glucose dehydrogenase method •Glucose Gluc-DH FSC Glucose dehydrogenase method •Glucose GOD FS 5' version GOD-PAP method •Glucose GOD FS 10' version GOD-PAP method • • • • •Glucose Hexokinase FS Hexokinase method • • • • • •
-HBDH FS UV test according to DGKC • • •HDL-C Immuno FS Direct immunoinhibition method • • • • • •Hemoglobin FS Hemiglobincyanide method •Homocysteine FS Enzymatic cycling method • •
-Hydroxybutyrate FS Enzymatic method • • • •Iron FS Ferene Ferene method • • • • • • •Lactate FS UV test with LDH • • • • •LDH FS DGKC UV test according to DGKC • • • •LDH FS IFCC UV test according to IFCC • • • • • •LDH FSC IFCC UV test according to IFCC •LDL-C Select FS Selective direct measurement • • • • •Lipase DC FS Enzymatic colorimetric method • • • • • •Magnesium XL FS Xylidyl blue method • • • • •NEFA FS (Non-esterified fatty acids) Enzymatic method • • •Pancreatic amylase CC FS EPS-G7 method • • • • •Phosphate FS UV test using molybdate • • • • • • •Phospholipids FS Enzymatic colorimetric test • •Total protein FS Biuret method • • • • • •Total protein FSC Biuret method •Total protein UC FS Pyrogallol red method • • • •Triglycerides FS 5' version GPO method • •Triglycerides FS 10' version GPO method • • • • •Triglycerides FSC GPO method •UIBC FS (Unsaturated iron binding capacity) Ferene method • • • •Urea FS Urease - GLDH method • • • • • •Urea FSC Urease - GLDH method •Urea CT FS Colorimetric method (Berthelot) • •Uric acid FS TBHBA Uricase-TBHBA method • • •Uric acid FS TOOS Uricase-TOOS method • • • • • • •
RZ_Dia_Kurz_Kat_281008 05.11.2008 12:56 Uhr Seite 5
Probedruck
C M Y CM MY CY CMY K
reagents
imm
unot
urbi
dim
etri
c te
sts
a – t
Product
05
Method RESP
ON
S®
Mul
tiple
-pur
pose
Hita
chi 9
11
Hita
chi 9
17
Oly
mpu
s AU
Pres
tige
24i
Sele
ctra
supplied systems*
immunoturbidimetric tests
* Additional information (for precise information concerning supplied analyzer types please refer to DiaSys product catalogue 2009)Multi-purpose Kits: DiaSys reagents in kits for multi-purpose and manual use - no analyzer specific bottlesKits for Hitachi 911: Full bar code; bottles suitable for several Hitachi and Olympus analyzers, as well as for Abbott Aeroset and Merck MEGAKits for Hitachi 917: Full bar code; bottles suitable for several Hitachi, Abbott Aeroset, Olympus and Advia analyzers, as well as for Abbott Aeroset and Merck MEGA Kits for Olympus AU systems: Fully barcoded bottles; suitable for Olympus AU 600/AU 400/AU 640/AU 2700/AU 5400Kits for Selectra Systems: Bottles suitable for Vitalab Selectra
Albumin in Urine/CSF FS (Microalbumin) Immunoturbidimetric test • • • • •Antistreptolysin O FS Particle enhanced immunoturbidimetric test • • • • •Apolipoprotein A1 FS Immunoturbidimetric test • • • • •Apolipoprotein B FS Immunoturbidimetric test • • • • •Complement C3c FS Immunoturbidimetric test • • •Complement C4 FS Immunoturbidimetric test • • •CRP FS Immunoturbidimetric test • • • • • •CRP U-hs Particle enhanced immunoturbidimetric test • • • •D-Dimer FS Particle enhanced immunoturbidimetric test • • •Ferritin FS Particle enhanced immunoturbidimetric test • • • • • HbA1c FS Particle enhanced immunoturbidimetric test • • • • •Immunoglobulin A FS Immunoturbidimetric test • • • • •Immunoglobulin E FS Particle enhanced immunoturbidimetric test • • •Immunoglobulin G FS Immunoturbidimetric test • • • • •Immunoglobulin M FS Immunoturbidimetric test • • • • •Lp(a) 21 FS Particle enhanced immunoturbidimetric test • • •Myoglobin FS Particle enhanced immunoturbidimetric test • • •Prealbumin FS Immunoturbidimetric test • • •Rheumatoid factor FS Immunoturbidimetric test • • • • • •Transferrin FS Immunoturbidimetric test • • • • • •
RZ_Dia_Kurz_Kat_281008 05.11.2008 12:56 Uhr Seite 6
Probedruck
C M Y CM MY CY CMY K
calibrators and standardsca
libr
ator
s · s
tand
ards
06
calibrators
TruCal U Multi-calibrator for clinical chemistryTruCal Protein Liquid-stable multi-calibrator for proteinsTruCal Protein high Liquid-stable multi-calibrator for proteinsTruCal Albumin U/CSF For use with Albumin in Urine/CSF FSTruCal Apo A1/B For use with Apolipoprotein A1 FS and Apolipoprotein B FSTruCal ASO For use with Antistreptolysin O FSTruCal CRP For use with CRP FSTruCal CRP 150 For use with CRP FSTruCal CRP high For use with CRP FS up to 500 mg/LTruCal CRP hs For use with CRP U-hs TruCal CRP U For use with CRP U-hs TruCal D-Dimer For use with D-Dimer FSTruCal Ferritin For use with Ferritin FSTruCal HbA1c liquid For use with HbA1c FSTruCal HDL/LDL For use with HDL-C Immuno FS and LDL-C Select FS TruCal Homocysteine For use with Homocysteine FSTruCal IgE For use with Immunoglobulin E FSTruCal Lp(a) 21 For use with Lp(a) 21 FSTruCal Myoglobin For use with Myoglobin FSTruCal RF For use with Rheumatoid factor FS
standards
Albumin Standard FS Iron Standard FSATP Standard FS Magnesium Standard FSBicarbonate Standard FS NEFA Standard FSCalcium Standard FS Phosphate Standard FSChloride Standard FS Phospholipids Standard FSCholesterol Standard FS Total protein Standard FSCreatinine Standard FS Total protein UC Standard FSEthanol Standard FS Triglycerides Standard FS (additional value for glycerol)
Glucose Standard FS Urea Standard FS-Hydroxybutyrate Standard FS Uric acid Standard FS
RZ_Dia_Kurz_Kat_281008 05.11.2008 12:56 Uhr Seite 7
Probedruck
C M Y CM MY CY CMY K
cont
rols
supp
lem
enta
ry r
eage
nts
spec
ial p
rodu
cts
07
additional products
supplementary reagents
special products
design 99° Grafikdesign · www.99grad.de
controls
TruLab N "Normal" control for clinical chemistryTruLab P "Pathological" control for clinical chemistryTruLab L Lipid controlTruLab Protein Liquid-stable protein controlTruLab Urine Control for analytes in urineTruLab Albumin U/CSF For use with Albumin in Urine/CSF FSTruLab Bicarbonate For use with Bicarbonate FSTruLab CRP For use with CRP FS and CRP U-hs TruLab CRP hs For use with CRP U-hs TruLab D-Dimer For use with D-Dimer FSTruLab Ethanol For use with Ethanol FSTruLab HbA1c liquid For use with HbA1c FSTruLab Homocysteine For use with Homocysteine FSTruLab Lp(a) For use with Lp(a) 21 FS
CK-MB DS Supplementary reagent for determination of CK-MBDouble signal for increased sensitivity and precision
Creatinine FS Supplement Supplementary reagent for elimination of bilirubin interference usingCreatinine FS
Creatinine FS Urine Diluent For use with Creatinine FS Supplement while measuring creatininein urine
Glucose Hemolyzing Solution For use with Glucose Gluc-DH FS and Glucose Gluc-DH FSC
HbA1c Hemolyzing Solution For use with HbA1c FS
HDL Precipitant Supplementary reagent for use with Cholesterol FS and Cholesterol FSC
LDL Precipitant Supplementary reagent for use with Cholesterol FS and Cholesterol FSC
Pyridoxal-5-Phosphate FS Supplementary reagent for IFCC recommended ASAT/ALAT determination
Cleaner 14 Alkaline cleaning solution
Mononucleosis Test for immunological determination of infectious mononucleosis
Urea test strips Test strips for the determination of urea in blood, serum and plasma
Urinary calculi analysis Reagent kit for semi-quantitative determination of the most important components of urinary calculi: calcium, oxalate, phosphate, magnesium, ammonium, uric acid and cystine
RZ_Dia_Kurz_Kat_281008 05.11.2008 12:56 Uhr Seite 8
Probedruck
C M Y CM MY CY CMY K
instruments
instruments
DiaSys Diagnostic Systems GmbH
Alte Strasse 9 :: 65558 Holzheim/Germany
Phone +49 (0) 64 32 /91 46-0 :: Fax +49 (0) 64 32 /91 46-32
[email protected] :: www.diasys-diagnostics.com
handed over by:
828100 | Edition 2009 | 11-2008
inst
rum
ents
SensoStar
InnovaStar®
Fully automated bench top random access clinical chemistry analyzer:: Throughput: 200 tests/h (360 tests/h with ISE):: Broad parameter menu: > 60 methods:: On board reagent capacity: 30 ready-to-use refrigerated reagents in bar coded mono or twin containers:: Long-term reagent stability: 12 - 24 months:: Sample tray positions: 39 for patient samples, calibrators and controls:: Flexible sample matrix: Serum, plasma, urine, CSF and whole blood:: STAT-sample capability:: Low sample volumes: 2 - 70 μL
Point-of-care Diabetes Analyzer:: Measurement of HbA1c, glucose and hemoglobin from one sample only:: HbA1c measurement standardized according to IFCC and DCCT/NGSP:: Automated dilution, mixing, incubation, calibration and measurement:: Photometric measurement
StarDust FCAutomatic flow cell photometer Semi-automated analyzer
:: High quality precision photometers for measurement of substrates, enzymes, electrolytes andimmunoturbidimetric tests, including serological parameters and specific proteins
:: Fully programmable, DiaSys tests pre-programmed:: Readings in absorbances, concentrations, kinetics, fixed time, ratio and multistandard
StarDust MC 15
Biosensor Glucose / Lactate Analyzers:: Biosensor technology for the measurement of glucose and/or lactate (Sensostar GLH one allows additional
photometric measurement of hemoglobin):: Specific enzymatic reactions lead to high accuracy and excellent precision:: Maintenance-free biosensor:: Automatic calibration:: Printer and EDP interface includedSensoStar GL one Simultaneous measurement of glucose and lactateSensoStar GLH one Simultaneous measurement of glucose and/or lactate and hemoglobinSensoStar G Measurement of glucose; high throughput: 200 tests/hourSensoStar GL Simultaneous measurement of glucose and lactate SensoStar GL 30 Simultaneous measurement of glucose and lactate
Sample rotor with 30 samples