Server TechnologyTechnical Data Sheet
PRO2™ Switched CDU®STV-4501: 20-30A/16-32A 208V/230V input with (24)C13 and (6)C19 outlets
The Server Technology® PRO2 Switched CDU provides control of outlet power and local LED input current monitoring, allowing IT personnel to determine safe levels of loading on a per-phase basis while installing equipment into the rack/cabinet. The integral PIPS® technology provides billing-grade accurate measurement of current, voltage, active power, apparent power, power factor, crest factor, and accumulated energy at the input. These power data points, along with temperature and humidity measurements (provided via optional probes), are accessible through the built-in Web and CLI interfaces as well as through SNMP. The PRO2 Switched "Master" CDU can be connected to as many as three PRO2 Switched "Link" CDUs to extend the network access to the redundant or secondary power feed without the risks of a daisy chain linking con�guration.
Oct. 2014 | Version 1.0
FeaturesNetwork MonitoringThe PRO2 hot-swappable network card provides for HTTP(S), SSH, Telnet, SNMP, (S)FTP, SMTP, Syslog, LDAP(S), RS-232 serial, and more.
Star Multi-LinkingPRO2 provides the ability to link up to four power circuits using one IP address. Primary link provides backup power to network card.
Hot-Swap Network CardNetwork access is ensured when power is lost to the Master unit with backup power provided by the prima-ry link unit.
Temperature/Humidity MonitoringPRO2 Master and Link units each support two external 10' (3m) T/H probes. Receive SNMP-based alerts and email noti�cations.
Outlet ControlOn PRO2 Switched CDUs, cycle power to individual outlets or groups of outlets to reboot servers. Or, power o� unused receptacles.
Auto-�ip Current DisplayEasy-to-read LEDs display current per phase to help prevent overloads and simplify three-phase load balancing in high-density cabinets.
Power Pivot™The 90 degree rotatable power cord allows for standardized deployment at any facility no matter where power must be routed.
High Retention Locking OutletsPRO2 receptacles have high retention and are compatible with Server Technology’s LockedIn™ power cords (sold separately).
ST Eye Bluetooth ReadyThe best CDU LCD is the one in your hand. Attach the ST Eye™ Bluetooth module to PRO2 for access to power data and system settings.
Branch Circuit ProtectionPRO2 meets the UL and IEC 60950-1 requirement for branch circuit protec-tion through use of UL489 rated magnetic-hydraulic circuit breakers.
Branch Current MonitoringPRO2 monitors current at each break-er branch and provides SNMP-based alerts and emails on high usage that risks a tripped circuit.
Per-Inlet Power SensingMeets ANSI C12.1 for billing-grade accuracy of Current per phase. PIPS includes voltage, active power, appar-ent power, power factor, and energy.
Color Identi�cationChoose from six colors to designate circuits for CDUs in the data center. Color options include Blue, Red, Green, White, Yellow, and Black
High Temperature RatingThis product has been tested and approved for safe and reliable opera-tion in 60°C (140°F) data center environments.
Cisco EnergyWise1 CompliantPRO2 meets the requirements set forth by Cisco System, Inc. for its EnergyWise program for monitoring of device energy.
Flexible MountingPRO2 includes standard button mounts along with provisions for custom mounting brackets (contact Server Technology for details).
Speci�cations
* Order PTCORD separately. Choose L6-20P, CEE 7/7 Schuko, IEC60309 2P+PE, or BS1363
Outputs• Connector: (24) x IEC 60320/C13 • North American Rating (C13): ≤ 12A @208-240V (15 peak) ; Global: ≤ 10A @220-240V• Connector: (6) x IEC 60320/C19 • North American Rating (C19): ≤ 16A @208-240V (20 peak) ; Global: ≤ 16A @220-240V• LockedIn™ compatible. Locking outlets provide high-retention even for non-locking cords
Input measurement accuracy• LED Current = ± 10% 0.1 amp (1.0 – 9.9amps) and 1 amp (>9.9amps) resolution• GUI Current = ± 1% at 0.01 amp resolution (above 0.5 amp)• Voltage = ± 1% at 0.1 volt resolution (nominal ± 10%)• Active Power = ± 1% at 1 watt resolution • Apparent Power = ± 1% at 1 volt-amp resolution• Power Factor = ± 3% at 0.01 resolution• Crest Factor = ± 10% at 0.1 resolution• Energy = ± 1% at 0.1 kilowatt-hour resolution
Branch measurement accuracy• Current = ± 3% at 0.01 amp resolution (above 0.5 amp)
Branch Circuit Protection• UL489 compliant 2-pole, 20A trip circuit breakers, Two (2) branches, Rating: ≤ 16A @208-240V
208-240V, L-L, 50/60HzSTV-4501C SEV-4501C ≤ 24A (30 peak)
Master CDU Link CDU Input VoltageInput CurrentInput Plug Rated Power
STV-4501A SEV-4501A IEC C20* 208-240V, L-L, 50/60Hz
3328W @208V≤ 16A (20 peak)
4992W @208VNEMA L6-30P, 10ft,3-C, 10AWG
STV-4501K SEV-4501K
Master CDU Link CDU Input VoltageInput CurrentInput Plug Rated Power
STV-4501A SEV-4501A IEC C20* 3680W @230V
7360W @230VIEC 60309 6hr
2P+PE Blue, 3m, H05VV-F, 4.0mm2
≤ 32A
≤ 16A 220-240, L-N,50/60Hz
220-240, L-N,50/60Hz
North America
Global
Speci�cations Cont.
Physical/Environmental• Dimensions: 69.00" (1753 mm) tall x 2.19” (56 mm) wide x 2.25" (57 mm) deep | Weight: 25 lbs (11.4 kg)• Shipping Dimensions: 73" x 7" x 3" (186 cm x 18 cm x 8 cm) | Weight: 26 lbs (11.8 kg)• Highlight Color: Choose Black, White, Red, Green, Blue, Yellow• Operating Environment: 32°F to 140°F / 0°C to 60°C | 8%RH to 90%RH non-condensing | 6,500ft/2000m elevation• Storage Environment: -40°F to 185°F / -40°C to 85°C | 8%RH to 90%RH non-condensing | 50,000ft/15km elevation• Quiescent / Unloaded Power Draw: < 10W for all con�gurations
Communications and Security • 10/100 Mbps Ethernet (RJ-45 connector), RS-232 serial (RJ-45 connector)• Two (2) temperature/humidity sensor inputs (4P4C), Link port (RJ-12) – {also on Link CDU}• Web-browser GUI and command-line-interface (CLI): HTTP/HTTPS, SSLv3/TLSv1, SSHv2, Telnet, SNMPv2c and v3
(GET, SET, Traps), IPv4 and IPv6, LDAPv3/LDAPS, TACACS+, RADIUS, FTP/SFTP
Certi�cations• cTUVus Mark to UL 60950-1:2007 and CAN/CSA 22.2 No. 60950-1-07 + A1:2011• TUV T-Mark to EN 60950-1:2006 + A11 + A1 + A12• EMC to EN 55022 Class A, EN 55024, CISPR 22 Class A• FCC Class A, Part 15• CE Mark• RoHS/WEEE
Optional Accessories• EMTH-1-1 Combination Temperature/Humidity Probe, 10ft (3m) • EMCU-1-1B Environmental Monitor adding:
- Two (2) EMTH-1-1 temperature/humidity ports (one probe included)- One (1) EMWS-1-1 water sensor port (probe sold separately)- Four (4) dry contact (NO/NC) monitoring points- One (1) 8-bit analog-to-digital converter (0 to 5VDC)
• SPM (Sentry® Power Manager):- Monitor and manage multiple PDUs from a single point- Monitor and manage alarm conditions- Create reports and trends on stored data- Analyze power usage per phase- Optional appliance or virtual version- VMware Ready2
• Mounting Brackets- Buttons (KIT-0020) included for tool-less mounting (see diagram).- See the Mounting Bracket Guide for further suggestions.- Custom mounting options available. Contact your local Server Technology representative.
• Cable Retention Devices for non-locking cords- EZip- Cable Sleeve- Wire Bails
Speci�cations Cont.
• Device / Output LockedIn™ Power Cords- UL Rated
• Device / Output LockedIn™ Power Cords- VDE Rated
- Additional sizes may be available. Contact your local Server Technology representative.
CAB-S1413-FA(FR)
Part Number Plug ColorLengthReceptacle
CAB-S1413-CA C14
C14 3.0 ft (0.9 m)
1.5 ft (0.45 m)
Black (Red)
Black
CAB-S1413-WA
CAB-S1413-NA(NR)
10.0 ft (3 m)
6.0 ft (1.8 m) Black (Red)
Black (Red)
Black (Red)
CAB-S1419-NA
CAB-S1419-FA
6.0 ft (1.8 m)
3.0 ft (0.9 m)
CAB-S2013-FA
CAB-S2013-CA C20
C20
C20
C20
C20
C20
3.0 ft (0.9 m)
1.5 ft (0.45 m)
CAB-S2019-CA
CAB-S2013-NA
1.5 ft (0.45 m)
6.0 ft (1.8 m)
CAB-S2019-NA(NR)
CAB-S2019-FA(FR)
6.0 ft (1.8 m)
3.0 ft (0.9 m)
C14
C14
C14
C14
C13
C13
C13
C13
C13
C19
C19
C19
C13
C13
C19
C19
Black
Black
Black
Black
Black
Black
Black
CAB-S1413-GV(GS)
Part Number Plug ColorLengthReceptacle
CAB-S1413-CV C14
C14 1.0 m (39 in)
0.5 m (20 in)
Black (Red)
Black
CAB-S2013-GV
CAB-S1413-PV(PS) 2.0 m (78 in)
2.0 m (78 in)
2.0 m (78 in)
Black (Red)
Black (Red)
Black (Red)
CAB-S2019-CV
CAB-S2013-PV
CAB-S2019-PV(PS)
CAB-S2019-GV(GS) C20
C20
C14
C14
C14
C14
C13
C13
C13
C13
C13
C19
C19
C19
Black
Black
Black0.5 m (20 in)
1.0 m (39 in)
1.0 m (39 in)
Dimensional Speci�cations
AA
BB
CC
DD
1 1
2 2
3 3
4 4
5 5
6 6
7 7
8 8
SE
RV
ER T
EC
HN
OLO
GY
, IN
CPR
OP
RIE
TAR
Y IN
FOR
MAT
ION
TH
IS D
OC
UM
ENT
IS T
HE
SO
LE P
RO
PER
TY O
F S
ERVE
R T
ECH
NO
LOG
Y, I
NC
.TH
E R
ELEA
SE O
F D
ATA
CO
NTA
INE
D IN
TH
IS D
OC
UM
EN
T AN
D T
HE
REP
RO
DU
CTI
ON
OF
THIS
DO
CU
MEN
T, IN
WH
OLE
OR
IN P
AR
T, W
ITH
OU
T TH
E W
RIT
TEN
PE
RM
ISS
ION
OF
SE
RV
ER T
ECH
NO
LOG
Y, IN
C IS
PR
OH
IBIT
ED
.
THES
E C
OM
MO
DIT
IES
, TE
CH
NO
LOG
Y O
R S
OFT
WA
RE
WER
E E
XPO
RTE
D F
RO
M T
HE
UN
ITE
D S
TATE
S IN
AC
CO
RD
AN
CE
WIT
H T
HE
EXP
OR
T A
DM
INIS
TRA
TIO
NR
EGU
LATI
ON
S.
DIV
ER
SIO
N C
ON
TRAR
Y TO
U.S
. LAW
IS P
RO
HIB
ITE
D.
RoH
S C
OM
PLIA
NT
FIN
ISH
:
MAT
ERIA
L:
SCAL
E:BSIZ
EC
AG
E C
OD
ED
WG
NO
.
SHEE
T
REV
SERV
ER T
ECHN
OLO
GY,
INC.
DR
AWIN
G T
ITLE
:
10
40 S
andh
ill D
rive
Ren
o, N
V 89
521
049V
0
THIR
D A
NG
LE P
RO
JEC
TIO
ND
O N
OT
SCAL
E D
RAW
ING
* R
EMO
VE A
LL B
UR
RS
AN
D S
HAR
P ED
GES
.2 R
MAX
* D
IMEN
SIO
NIN
G &
TO
LER
ANC
ING
IAW
ASM
E Y1
4.5M
-200
7*
INTE
RPR
ET
DR
AWIN
G IA
W A
SME
Y14.
100-
2000
* D
IMEN
SIO
NS
ARE
IN M
ILLI
MET
ERS
UN
LESS
OTH
ERW
ISE
SPEC
IFIE
D
NO
NE
412-
0761
-21
1
OU
TLIN
E D
RAW
ING
, SW
ITC
HED
, PI
PS/P
OPS
, V30
, (24
)C13
, (6)
C19
1 O
F 3
* DIM
ENSI
ON
AL L
IMIT
S AP
PLY
AFTE
R P
LATI
NG
/CO
ATIN
G.
TOLE
RAN
CES
(UN
LESS
OTH
ER
WIS
E S
PEC
IFIE
D)
LIN
EAR
DIM
ENSI
ON
S:.X
= ±
.500
.XX
= ±
.300
.XXX
= ±
.130
ANG
ULA
R D
IMEN
SIO
NS:
X =
± 1
°X.
X =
± .5
°X.
XX =
± .2
5°
Q #
= C
RIT
ICAL
DIM
.
S=
CO
SM
ETIC
SU
RFA
CE
SYM
BOLS
REV
ISIO
N H
ISTO
RY
ZON
ER
EVD
ESC
RIP
TIO
ND
ATE
APPR
OVE
D-
GP/M
RJ3102/21/8
NGISE
D LAITINI
1
NO
TES:
1.
DIM
ENSI
ON
S AR
E IN
MIL
LIM
ETER
S AN
D [
] AR
E IN
INC
HES
.
2.
D
IMEN
SIO
NS
ARE
NO
MIN
AL. I
NFO
RM
ATIO
N S
UBJ
ECT
TO C
HAN
GE
WIT
HO
UT
NO
TIC
E.
933.
45 [3
6.75
]
86.15
[3.39
]
1752
.60 [6
9.00]
55.50
[2.19
]57
.15 [2
.25]
68.4
0 [2
.69]
12.7
0 [0
.50]
4X31
.25
[1.2
3]68
.40
[2.6
9]
98.4
3 [3
.88]
1555
.75
[61.
25]
98.4
3 [3
.88]
419.
60 [1
6.52
]39
9.55
[15.
73]
20.0
0 [0
.79]
31.2
5 [1
.23]
20.0
0 [0
.79]
399.
55 [1
5.73
]93
3.45
[36.
75]
419.
60 [1
6.52
]
Wiring and Breaker Trip Curve
BreakerTrip Curve
GND
GND
CB
PLUGL1
L2/NEUT
CBGNDGNDGND
CT
BRANCH 1 (1-15)
BRANCH 2(16-30)
Part Number Certification Input Output
Master Expansion Rating Standard Rating Input TypeTotal Output Rating
Outlet Type and Ratings
Branch Circuit Rating
C2W30VA-2ABA2SD8 (STV-4501A)
C2X30VA-2ABA2SD8 (SEV-4501A)
cTUVus and/or cULus
208-240V 2P+PE, 50/60Hz; 16A IEC C20
240V, 50/60Hz; <= 16A
IEC 60320: 6xC19 <= 16A each, 24xC13 <= 12A
2 branches, each <= 16A
TUVGS230V 2P+PE, 50/60Hz; 16A IEC C20
240V, 50/60Hz; <= 16A
IEC 60320: 6xC19 <= 16A each, 24xC13 <= 10A
2 branches, each <= 16A
C2W30VA-2CBA2SD8 (STV-4501C)
C2X30VA-2CBA2SD8 (SEV-4501C)
cTUVus and/or cULus
208-240V 2P+PE, 50/60Hz; 24A NEMA L6-30P
240V, 50/60Hz; <= 24A
IEC 60320: 6xC19 <= 16A each, 24xC13 <= 12A
2 branches, each <= 16A
C2W30VA-EPBA2SD8 (STV-4501K)
C2X30VA-EPBA2SD8 (SEV-4501K) TUVGS
230V 2P+PE, 50/60Hz; 32A IEC 60309 32A
240V, 50/60Hz; <= 32A
IEC 60320: 6xC19 <= 16A each, 24xC13 <= 10A
2 branches, each <= 16A
Warranty: Server Technology o�ers a standard 2-year limited parts & labor warranty. Extended support is available at the time of purchase. See the Support Options on the website, or contact your local Server Tech-nology representative for more information.
Patents: Information on Server Technology patents is available on the website at:
www.servertech.com/products/patents
PIPS, POPS, CDU, Sentry, Server Technology, and the globe logo are U.S. registered trademarks of Server Tech-nology, Inc. Power Pivot, ST Eye, LockedIn and PRO2 are trademarks of Server Technology, Inc.
Information in this document is current as of time of publishing. Contact your Server Technology representa-tive for the most up-to-date information. © 2014 Server Technology, Inc.
1 Cisco EnergyWise is a U.S. registered trademark of Cisco Technology, Inc.
2 VMware and VMware Ready is a registered trademark or trademark of VMware, Inc. in the United States and/or other jurisdictions.
Additional Information
Central Europe, Eastern Europe and RussiaNiederlassung DeutschlandServer Technology LLC42119 WuppertalGermanyTel: + 49 202 693917 x 0Fax: + 49 202 [email protected]
HEADQUARTERS - NORTH AMERICAServer Technology, Inc.1040 Sandhill DriveReno, NV 89521United States1.775.284.2000 Tel1.775.284.2065 [email protected]
Western Europe, Middle East and AfricaServer TechnologyFountain Court2 Victoria SquareVictoria StreetSt. AlbansAL1 3TFUnited Kingdom+44 (0) 1727 884676 Tel +44 (0) 1727 220815 [email protected]
APACServer TechnologyRoom 2301, 23/F, Future Plaza111-113 How Ming Street, Kwun Tong, Hong KongDirect line: +852 3916 2048Fax Line: +852 3916 [email protected]