Using SIFT Algorithm for Verification of Ear Biometric
Amrita Pathak, Gauri Gupta,Y7211062
Y7104022, [email protected],[email protected]
CS698x projectInstructor: Dr P Gupta
Abstract- This project presents a method for extracting distinctive invariant features
from ear images that can be used to perform reliable matching between different views
of an ear. It shows the extraction of keypoints in an ear image and also the results of it
are matching with other samples of both same and different subjects. It also validates
the behavior of SIFT algorithm on ear images of different subjects by clearly varying
the illumination, scale, rotation and also occluding some parts of the image. The feature
matching is found to perform well under the above mentioned varying conditions. The
FAR, FRR and accuracy curves obtained as a result of experimenting with data of 50
subjects, prove that the SIFT features are highly distinctive. This implies that a singlefeature can be correctly matched with high probability against a large database of
features.
1. IntroductionEar biometric system uses features of the ear (Figure 1) to identify or verify an individuals’
identity. The Comparison is based on variations of the complex structure of the ear. Ear
growth after the first four months of birth is proportional to gravity can cause the ear to
undergo stretching. Although humans lack the ability to recognize one another from ears, ears
have both reliable and robust features which are extractable from a distance .Other biometrics
such as Fingerprints, Hand Geometry and Retinal Scans require close contact and may be
considered invasive by users .Study by Iannnarelli showed the feasibility of ear biometrics
[1]. Possible applications for ear are Biometrics ATM Machines, Evidence surveillance and
recognition systems or access to any restricted area.
Figure 1: Structure of External Ear
7/23/2019 SIFT Algorithm for Verification of Ear Biometric
http://slidepdf.com/reader/full/sift-algorithm-for-verification-of-ear-biometric 2/13
2. Related WorkThere has been quite a bit of work on ear biometric. Iannarelli System is anthropometric
technique based upon the 12 ear measurements. It requires exact alignment and normalization
of the ear photo and allows comparable measurements. All measurements are relative to an
origin which is a point chosen on the image. Hui Chen and Bir Bhanu introduced a two-step
ICP (Iterative Closest Point) algorithm for matching 3D ears and Contour Matching for 3DEar Recognition [2]. Eigenear and PCA based approach have also been used for ear
identification [3].
3. SIFT: Shift Invariant Feature Transform
The algorithm has four stages [4]:
3.1 Scale Space Extrema Detection
This is the stage where the interest points, which are called keypoints in the SIFT framework,
are detected. For this, the image is convolved with Gaussian filters at different scales, and
then the difference of successive Gaussian-blurred images is taken. Key points are then taken
as maxima/minima of the Difference of Gaussians (DoG) that occur at multiple scales.
Specifically, a DoG image D(x,y,σ) is given by
Where L(x,y,k σ ) is the original image I(x,y) convolved with the Gaussian blur G(x,y,k σ ) at
scale k σ, i.e.,
Hence a DoG image between scales k iσ and k jσ is just the difference of the Gaussian-blurred
images at scales k iσ and k jσ. For scale-space extrema detection in the SIFT algorithm, the
image is first convolved with Gaussian-blurs at different scales. The convolved images aregrouped by octave (an octave corresponds to doubling the value of σ), and the value of k i is
selected so that we obtain a fixed number of convolved images per octave. Then the
Difference-of-Gaussian images are taken from adjacent Gaussian-blurred images per octave.
Once DoG images have been obtained, key points are identified as local minima/maxima of
the DoG images across scales. This is done by comparing each pixel in the DoG images to its
eight neighbors at the same scale and nine corresponding neighboring pixels in each of the
neighboring scales. If the pixel value is the maximum or minimum among all compared
pixels, it is selected as the candidate keypoint.
3.2 Keypoint LocalizationAfter scale space extrema are detected the SIFT algorithm discards low contrast key points
and then filters out those located on edges. Resulting set of keypoints is shown in Figure 2(a).
Scale space extrema detection produces too many keypoint candidates, some of which are
unstable. The next step in the algorithm is to perform a detailed fit to the nearby data for
accurate location, scale, and ratio of principal curvatures. This information allows points to
be rejected that have low contrast (and are therefore sensitive to noise) or are poorly localized
along an edge.
3.2.1 Interpolation of nearby data for accurate position
First, for each candidate key point, interpolation of nearby data is used to accurately
determine its position. The approach calculates the interpolated location of the maximum,
which substantially improves matching and stability. The interpolation is done using the
7/23/2019 SIFT Algorithm for Verification of Ear Biometric
http://slidepdf.com/reader/full/sift-algorithm-for-verification-of-ear-biometric 3/13
quadratic Taylor expansion of the Difference-of-Gaussian scale-space function, D(x,y,σ ) with
the candidate keypoint as the origin. This Taylor expansion is given by:
Where D and its derivatives are evaluated at the candidate keypoint and x=( x,y,σ ) is the offset
from this point. The location of the extremum, , is determined by taking the derivative of
this function with respect to x and setting it to zero. If the offset is larger than 0.5 in any
dimension, then that's an indication that the extremum lies closer to another candidate
keypoint. In this case, the candidate keypoint is changed and the interpolation performed
instead about that point. Otherwise the offset is added to its candidate keypoint to get the
interpolated estimate for the location of the extremum.
3.2.2 Discarding low-contrast keypoints
To discard the keypoints with low contrast, the value of the second-order Taylor expansion
D(x) is computed at the offset . If this value is less than 0.03, the candidate keypoint isdiscarded. Otherwise it is kept, with final location and scale σ, where y is the original
location of the keypoint at scale σ.
3.2.3 Eliminating edge responses
The DoG function will have strong responses along edges, even if the candidate keypoint is
unstable to small amounts of noise. Therefore, in order to increase stability, we need to
eliminate the keypoints that have poorly determined locations but have high edge responses.
For poorly defined peaks in the DoG function, the principal curvature across the edge would
be much larger than the principal curvature along it. Finding these principal curvatures
amounts to solving for the eigenvalues of the second-order Hessian matrix, H:
The eigenvalues of H are proportional to the principal curvatures of D. It turns out that the
ratio of the two eigenvalues, say α is the larger one, and β the smaller one, with ratio r=α / β , is
sufficient for SIFT's purposes. The trace of H, i.e. D xx + D yy, gives us the sum of the two
eigenvalues, while its determinant, i.e D xx D yy-D2 xy, yields the product. The ratio
R=Tr(H)2/Det(H) can be shown to be equal to (r+1)2/r, which depends only on the ratio of the
eigenvalues rather than their individual values. R is minimum when the eigenvalues are equalto each other. Therefore the higher the absolute difference between the two eigenvalues,
which is equivalent to a higher absolute difference between the two principal curvatures of D,
the higher the value of R. It follows that, for some threshold eigenvalue ratio r th, if R for a
candidate keypoint is larger than r th+1)2/r th, that keypoint is poorly localized and hence
rejected. The new approach uses r th = 10
3.3 Orientation Assignment
In this step, each keypoint is assigned one or more orientations based on local image gradient
directions. This is the key step in achieving invariance to rotation as the key point descriptor
can be represented relative to this orientation and therefore achieve invariance to image
7/23/2019 SIFT Algorithm for Verification of Ear Biometric
http://slidepdf.com/reader/full/sift-algorithm-for-verification-of-ear-biometric 4/13
rotation. First, the Gaussian-smoothed image L( x,y,σ) at the keypoint's scale σ is taken so that
all computations are performed in a scale-invariant manner. For an image sample L( x,y) at
scale σ, the gradient magnitude, m(x,y), and orientation, Θ(x,y), are pre-computed using pixel
differences:
The magnitude and direction calculations for the gradient are done for every pixel in a
neighboring region around the keypoint in the Gaussian-blurred image L. An orientation
histogram with 36 bins is formed, with each bin covering 10 degrees. Each sample in the
neighboring window added to a histogram bin is weighted by its gradient magnitude and by a
Gaussian-weighted circular window with a σ that is 1.5 times that of the scale of thekeypoint. The peaks in this histogram correspond to dominant orientations. Once the
histogram is filled, the orientations corresponding to the highest peak and local peaks that are
within 80% of the highest peaks are assigned to the keypoint. In the case of multiple
orientations being assigned, an additional keypoint is created having the same location and
scale as the original keypoint for each additional orientation.
3.4 Keypoint Descriptor
Previous steps found keypoint locations at particular scales and assigned orientations to them
and ensured invariance to image location, scale and rotation. Now we compute descriptor
vectors for these keypoints such that the descriptors are highly distinctive and partially
invariant to the remaining variations, like illumination, 3D viewpoint, etc. The featuredescriptor is computed as a set of orientation histograms on (4 x 4) pixel neighborhoods. The
orientation histograms are relative to the keypoint orientation and the orientation data comes
from the Gaussian image closest in scale to the keypoint's scale, the contribution of each
pixel is weighted by the gradient magnitude, and by a Gaussian with σ 1.5 times the scale of
the keypoint. Histograms contain 8 bins each, and each descriptor contains a 4x4 array of 16
histograms around the keypoint. This leads to a SIFT feature vector with (4 x 4 x 8 = 128
elements). This vector is normalized to enhance invariance to changes in illumination.
4. AlgorithmsWe have framed some algorithms to get the results which are described in the following sub-
sections.
4.1 Matching Algorithm
• find SIFT keypoints for each image and initialize
• Initialize a distance ratio threshold (dRatio).
•
For each descriptor vector in the first image(des1)
– Compute vector of dot products with descriptor vector of second image(des2)
i.e. dProd=des1.des2
– Take inverse cosine and sort results [value,index]=sort(acos(dProd))
– If nearest neighbour has angle less than dRatio times 2nd then match else
don’t match.
•
Return the number and percentage of keypoints matched
7/23/2019 SIFT Algorithm for Verification of Ear Biometric
http://slidepdf.com/reader/full/sift-algorithm-for-verification-of-ear-biometric 5/13
4.2 Algorithm to Find FRR
• Total samples in the database = 50
• Total number of queries = 50
• Match each query image with the corresponding other sample of the database
• Get the percentage match and store
•
For threshold (T) ranging from 0 to 100 – For each score value i (ranging from 1 to 50)
–
If score (i) <T then count as false rejected i.e. FRR(T)=FRR(T)+1
• Find percentage of each FRR value
• Plot FRR against threshold ranging from 0 to 100.
4.3 Algorithm to Find FAR
• Total samples in the database = 50
• Total number of queries = 50
• Match each query image with all the other images in the database except its own
sample.• Get the percentage match and store
• For threshold (T) ranging from 0 to 100
–
For each score value i (ranging from 1 to 2450)
– If score (i)>T then count as false accepted i.e. FAR(T)=FAR(T)+1
•
Find percentage of each far value
Plot FAR against threshold ranging from 0 to 100
4.4 Algorithm to Find Accuracy
• For the percentage scores for FAR and FRR
– Accuracy = 100-((FAR+FRR)/2)
•
Plot accuracy against threshold ranging from 0 to 100.•
Find the threshold for maximum accuracy
5. Results5.1 Results of using SIFT on ear for general matching under controlled environment
(a) Keypoints shown on an ear image (b)Keypoint matching of same ear (65
matches found out of 83)
7/23/2019 SIFT Algorithm for Verification of Ear Biometric
http://slidepdf.com/reader/full/sift-algorithm-for-verification-of-ear-biometric 6/13
(c)Keypoint matching of different ears (0
matches found out of 79)(d) Keypoint matching after changing
brightness (uniformly) (44 matches
found out 83)
(e) Keypoint matching after rotation by 45
degrees (39 matches found out of 83)
Figure 2: Results obtained after matching ear under controlled environment
5.2 Results of using SIFT on ear for matching under strained environment
5.2.1 Results Obtained by Changing Illumination
Subject Total number
of keypointsfound
Total number
of keypointsmatched
Percentage
matching
Type of
illuminationchange
See
figure
1 96 0 0 Large 3(a)
2 29 0 0 Large 3(b)
3 168 35 20.833 medium 3(c)
4 234 72 30.769 small 3(d)
Conclusion: SIFT gives good results for small to medium illumination changes but not for
large changes.
7/23/2019 SIFT Algorithm for Verification of Ear Biometric
http://slidepdf.com/reader/full/sift-algorithm-for-verification-of-ear-biometric 7/13
(a)
Subject 1 (b) Subject2
(c) Subject 3 (d) Subject 4
Figure 3: Matching Results Obtained After Changing Illumination for 4 subjects
5.2.2 Results Obtained by Changing Scale
Subject Database
image size
Query
image
size
Total
number of
keypoints
found
Total
number of
keypoints
matched
Percentage
matching
See Figure
1 302X418 516X713 152 52 34.210 4(a)
1 390X266 666X440 93 18 19.354 4(b)
2 191X381 338X642 546 36 6.593 4(c)
2 586X476 342X265 843 49 5.812 4(d)
Conclusion: SIFT gives optimum match results even when scale of the image is changed
7/23/2019 SIFT Algorithm for Verification of Ear Biometric
http://slidepdf.com/reader/full/sift-algorithm-for-verification-of-ear-biometric 8/13
(a)
Subject 1(b) Subject 1
(c) Subject 2(d) Subject 2
Figure 4: Matching Results Obtained After Changing Scale for 2 subjects.
5.2.3 Results Obtained by Changing RotationSubject Total number
of keypoints
found
Total number
of keypoints
matched
Percentage
matching
Type of
rotation of ear
See
figure
1 431 13 3.016 Completely
forward
5(a)
1 843 18 2.135 Completely
backward
5(b)
2 126 8 6.349 Completely
forward
5(c)
3 370 15 4.054 Completely
backward
5(d)
Conclusion: SIFT gives optimum match results even when image rotation is changed
7/23/2019 SIFT Algorithm for Verification of Ear Biometric
http://slidepdf.com/reader/full/sift-algorithm-for-verification-of-ear-biometric 9/13
(a) Subject 1 (b) Subject 1
(c) Subject 2 (d) Subject 3
Figure 5: Matching Results Obtained After Changing Rotation for 3 subjects
5.2.4 Results Obtained by Occluding a Part of ImageSubject Total number
of keypoints
found
Total number
of keypoints
matched
Percentage
matching
Amount of
Occlusion
See
figure
1 291 3 1.031 Large 6(a)
2 968 1 .1033 Large 6(b)
3 267 40 14.981 Medium 6(c)
3 284 51 17.957 Small 6(d)
Conclusion: SIFT gives good results for small to medium amount of occlusion but not for
large occlusion.
(a) Subject 1 (b) Subject 2
7/23/2019 SIFT Algorithm for Verification of Ear Biometric
http://slidepdf.com/reader/full/sift-algorithm-for-verification-of-ear-biometric 10/13
(c) Subject 3 (d) Subject 3
Figure 6: Matching Results Obtained After occluding images of 3 subjects
5.3 Results obtained after plotting FAR, FRR and accuracy
Figure 7: FAR-FRR Curve
7/23/2019 SIFT Algorithm for Verification of Ear Biometric
http://slidepdf.com/reader/full/sift-algorithm-for-verification-of-ear-biometric 11/13
Figure 8: Accuracy Curve
Figure 9: ROC Curve
7/23/2019 SIFT Algorithm for Verification of Ear Biometric
http://slidepdf.com/reader/full/sift-algorithm-for-verification-of-ear-biometric 12/13
Figure 10: DET Curve
6. ConclusionThe result obtained by plotting the curves is as follows:
Accuracy = 99.4485%
Threshold = 4
i.e. we get maximum accuracy at threshold = 4.
From several experiments conducted we conclude that the SIFT algorithm is robust to
changes in scale and rotation for the ear biometric. It gives good results for small to medium
illumination changes but not for large changes. It gives good results for small to medium
occlusion but not for large occlusion. It is not an efficient algorithm (with respect to
computational speed) for large database.
7. References
1. A. Iannarelli, Ear Identification. Foresic Identification Series. Paramont
PublishingCompany, Fremont, California, 1989.
2.
Hui Chen and Bir Bhanu, Contour Matching for 3D Ear Recognition
Center for Research in Intelligent Systems University of California, Riverside,
California
3. Mark Burge, Wilhelm Burger, "Ear Biometrics in Computer Vision," icpr,pp.2822, 15th
International Conference on Pattern Recognition (ICPR'00) - Volume 2, 2000
.
7/23/2019 SIFT Algorithm for Verification of Ear Biometric
http://slidepdf.com/reader/full/sift-algorithm-for-verification-of-ear-biometric 13/13
4. David G. Lowe, “Distinctive Image Features from Scale-Invariant Keypoints”,
International Journal of Computer Vision, 2004
5. P. Yan and K. B. Bowyer. 2D and 3D ear recognition. Biometric
Consortium Conference, 2004
6. www.cse.huji.ac.il/course/2006/compvis/lectures/