HYDROTROLSENGINEERED WATER HAMMER ARRESTERS
FUNCTION: Engineered water hammer arresters ("Hydrotrols") employ a permanently sealed cushion of air or gas which absorbsthe energy of water hammer and reduces pressure rise in the piping system to a safe level. Hydrotrol units correctly sized andplaced at specific locations in the water piping system, will control the destructive shock of water hammer.
RECOMMENDED SPECIFICATION FOR HYDROSTATIC SHOCK CONTROLSmith series 5000 "Hydrotrol" all stainless steel shock absorbers shall be installed at all solenoid, remote operated or quick closing valves and at each plumbing fixture or battery of plumbing fixtures. Install on both hot and cold water branch lines in an upright position as close as possible to the valve or valves being served. Sizes and locations as indicated on drawings.
PCN/Fig. No.
500550105020503050405050
P.D.I.Symbol
ABCDEF
Fixture UnitRating1-1112-3233-6061-113114-154155-330
ASIZE
3/4 (19)1 (25)1 (25)1 (25)1 (25)1 (25)
B
Hydrotrols Fig. 5005 to 5050 inclusive have beentested and certified in accordance with the Plumbingand Drainage Institute "Standard P.D.I. WH-201"
Hydrotrols are pre-charged and permanently sealed at the factory.All hydrotrols are constructed entirely of stainless steel.
NOTE: Sizing information on reverse side.
5005 To 5050
5005
To
5050
CM
KG
TD2-
12-8
6N
ON
ES5
005
N
D
1.80 (46)2.13 (54)2.42 (61)3.38 (86)3.57 (91)4.50 (114)
C
B
90º
A
CompressionChamber
Shell
Nipple
Units: A, B, C, & D
D
C
B
CompressionChamber
Shell
Units: E & F
D
90º
A
NOTE: Dimensions shown in parentheses are in millimeters.
NOTE: Stainless steel units are lead-free.
L 01/20/11 Updated Logo JJ TWM 11-2-11 Rev. "B" & "D" Dim., Drawing TBW JMN 10-15-13 Revised Function TBW CL