HUMINATORhigh precision humidity lab
calibration validation training
– individually
programmable
– easy to run menu
– graphic display
– RS-232 Interface
industrial services
temperature control
15°-40° C
humidity range
5-95% RH
HuminatorUsing the HUMINATOR you can quicklyand easily calibrate humidity measuringinstruments, probes and data loggersfrom Testo and other companies. TheHUMINATOR calibration system is a high-
performance, stand alone temperature/humidity reference generator. It features athermal servo system to stabilize tempe-rature in the range of 15 to 40°C. RelativeHumidity is rapidly generated in the range
of 5 to 95%.With the special Testo front panel of thechamber it is possible to calibrate 4 humi-dity probes at the same time. It is alsopossible to calibrate various data loggers.
I would like to order the items as indicated above:Please contact me at the address below:
name
company
date, signature
calibration validation trainingindustrial services
Your Testo-Partner:
Qty Discription Part no. Price Technical Data HUMINATOR
Recommended set for the HUMINATOR:HUMINATOR incl. Testo sensor and 15 probe adapters 0519.0801
testo 6502 channel reference temperature and humidity measuringinstrument with pressure measurement 0563.6501
Mains unit for testo 650 230 V/8 V/1 A 0554.1084
Highly accurate reference humidity/temperature probe+1%RH accuracy 0636.9741
Plug-in head cableto connect probe to measuring instrument 0430.0143
DKD calibration measuring points: 11,3, 30, 50, 75,3, 90%RH at +25°C 0520.0216
Case for HUMINATOR 0519.0820
Temperature range:................................................15 to 40°CHumidity range: ....................................................5 to 95%RHPower supply:................................85 to 264 VAC, 47 to 63 HzInterface: ........................................................................RS 232Display: ..............................................................Grafical displayDimension meas. chamber: ................ca. 147 mm diameter....................................................................probe depth 170 mm
Dimension: ..............................................................19 zoll rackAccuracy:..................................................Temperature 0,5°C
(10-85%RH at 25°C)Humidity 2%RH(10-85%RH at 25°C)
Stability: ............................................................................0,2°C(10-85%RH at 25°C)
..........................................................................................1% RH(10-85%RH at 25°C)
Supplement: ....................drying container with drying reagent
Weight ............................................................................14,5 kg