8/17/2019 TMO 18552-B WCDMA 9712 LR OD and 9711 LR ID Cabinet Layout _ 14w34.pdf
http://slidepdf.com/reader/full/tmo-18552-b-wcdma-9712-lr-od-and-9711-lr-id-cabinet-layout-14w34pdf 1/82
All Rights Reserved © Alcatel-Lucent 2006
9712 LR Outdoor Cabinet
9711 LR Indoor Cabinet
Layout Description
Course Reference:
GPEC
August 2014
8/17/2019 TMO 18552-B WCDMA 9712 LR OD and 9711 LR ID Cabinet Layout _ 14w34.pdf
http://slidepdf.com/reader/full/tmo-18552-b-wcdma-9712-lr-od-and-9711-lr-id-cabinet-layout-14w34pdf 2/82
All Rights Reserved © Alcatel-Lucent 2006August 2014
Agenda
9712 LR Outdoor Cabinet Documentation
9711 LR Indoor Cabinet Documentation
971x LR ID or LR OD Cabinet Common Modules Description
9712 LR Outdoor Cabinet Description
9712 LR Outdoor Cabinet Site Preparation
9712 LR Outdoor Cabinet Layout Description
9711 LR Indoor Cabinet Description
9711 LR Indoor Cabinet Site Preparation
9711 LR Indoor Cabinet Layout Description
8/17/2019 TMO 18552-B WCDMA 9712 LR OD and 9711 LR ID Cabinet Layout _ 14w34.pdf
http://slidepdf.com/reader/full/tmo-18552-b-wcdma-9712-lr-od-and-9711-lr-id-cabinet-layout-14w34pdf 3/82
All Rights Reserved © Alcatel-Lucent 2006
9712 LR Outdoor Cabinet
9711 LR Indoor Cabinet
Documentation
8/17/2019 TMO 18552-B WCDMA 9712 LR OD and 9711 LR ID Cabinet Layout _ 14w34.pdf
http://slidepdf.com/reader/full/tmo-18552-b-wcdma-9712-lr-od-and-9711-lr-id-cabinet-layout-14w34pdf 4/82
All Rights Reserved © Alcatel-Lucent 2006
9326 d2U / 9926 BBU Distributed Node B
All related documents for Distributed Node B are available under the following links:
https://all1.na.alcatel-lucent.com/Teams/GCDNetworks/WirelessGPEC/default.aspx?Product=WCDMA&LocationType=
Select 9712 LR Outdoor Cabinet or
Select 9926 DBS (Distributed Base Station BBU 2U or D4U)
Select Common UTRAN Documentation (Platform Independent) for IEH 521
Select MC RRH for IEH 523 Installation Engineering Handbook 523 Multi-Standard RF
July 2014
GPEC Training: Presentations of eModules and MD8 Eltek PSU Cabinet.https://all1.na.alcatel-lucent.com/Teams/GCDNetworks/WirelessGPEC/DeliveryReadiness/WCDMA/UTRAN/Training/W-CDMA_trainings.html
KTS Board Introduction in UA7.1.3 https://wcdma-ll.app.alcatel-
lucent.com/livelink/livelink.exe?func=ll&objId=63222614&objAction=Open&nexturl=%2Flivelink%2Flivelink%2Eexe%3Ffunc%3Dll%26objId%3D6304413
9%26objAction%3Dbrowse%26viewType%3D1
8/17/2019 TMO 18552-B WCDMA 9712 LR OD and 9711 LR ID Cabinet Layout _ 14w34.pdf
http://slidepdf.com/reader/full/tmo-18552-b-wcdma-9712-lr-od-and-9711-lr-id-cabinet-layout-14w34pdf 5/82
All Rights Reserved © Alcatel-Lucent 2006
9712 LR Outdoor Cabinet Documentation
5 | Distributed Node B Commissioning | Ju ly 2014
for 9712 LR Outdoor Cabinet: (available under GPEC portal WCDMA)
https://all1.na.alcatel-lucent.com/Teams/GCDNetworks/WirelessGPEC/default.aspx?Product=WCDMAUTRAN&LocationType=Documents
8/17/2019 TMO 18552-B WCDMA 9712 LR OD and 9711 LR ID Cabinet Layout _ 14w34.pdf
http://slidepdf.com/reader/full/tmo-18552-b-wcdma-9712-lr-od-and-9711-lr-id-cabinet-layout-14w34pdf 6/82
All Rights Reserved © Alcatel-Lucent 2006
9711 LR Indoor Cabinet Documentation
6 | Distributed Node B Commissioning | Ju ly 2014
for 9711 LR Indoor Cabinet: (available under GPEC portal WCDMA)
https://all1.na.alcatel-lucent.com/Teams/GCDNetworks/WirelessGPEC/default.aspx?Product=WCDMAUTRAN&LocationType=Documents
8/17/2019 TMO 18552-B WCDMA 9712 LR OD and 9711 LR ID Cabinet Layout _ 14w34.pdf
http://slidepdf.com/reader/full/tmo-18552-b-wcdma-9712-lr-od-and-9711-lr-id-cabinet-layout-14w34pdf 7/82
All Rights Reserved © Alcatel-Lucent 2006
971x LR ID or LR OD Cabinet
Common Modules
Description
8/17/2019 TMO 18552-B WCDMA 9712 LR OD and 9711 LR ID Cabinet Layout _ 14w34.pdf
http://slidepdf.com/reader/full/tmo-18552-b-wcdma-9712-lr-od-and-9711-lr-id-cabinet-layout-14w34pdf 8/82
All Rights Reserved © Alcatel-Lucent 2006
971x LR ID or OD Cabinet - Common Module Presentation
8 | 9712 LR OD Cabinet Presentation| August 2014
Digital controller
The lightRadio Outdoor cabinet supports 4 types of digital controllers:
(*) SUMx19” is 1.5HU, ½ U space is required on the top of the SUMX19 for thermal constraint.
8/17/2019 TMO 18552-B WCDMA 9712 LR OD and 9711 LR ID Cabinet Layout _ 14w34.pdf
http://slidepdf.com/reader/full/tmo-18552-b-wcdma-9712-lr-od-and-9711-lr-id-cabinet-layout-14w34pdf 9/82
All Rights Reserved © Alcatel-Lucent 2006
971x LR ID or OD Cabinet - Common Module Presentation
9 | 9712 LR OD Cabinet Presentation| August 2014
The physical characteristics are the followings:Radio module
These modules required a Subrack in LR OD:
(*) one HU is always required on bottom of the subrack for air inlet.
The lightRadio outdoor cabinet supports the following
Radio module:
The MC-TRDU 900 & 1800, TRDU 2x80-21 and 2x60 800are self-contained, 19 inch form factor modules, directly
installed inside the cabinet, without subrack.The modules are delivered with two front panels to fix theTRDU on the cabinet.
· In the lightradio indoor cabinet, the front panels are moved tothe middle of the module and then fixed to the cabinet.
· In the lightradio outdoor cabinet, the TRDU is fixed onthe cabinet with the front panel, but an additional sidebracket support must be used to support the TRDU weight.
These modules required a Subrack in LR ID:
8/17/2019 TMO 18552-B WCDMA 9712 LR OD and 9711 LR ID Cabinet Layout _ 14w34.pdf
http://slidepdf.com/reader/full/tmo-18552-b-wcdma-9712-lr-od-and-9711-lr-id-cabinet-layout-14w34pdf 10/82
All Rights Reserved © Alcatel-Lucent 2006
971x LR ID or OD Cabinet - Common Module Presentation
10 | 9712 LR OD Cabinet Presentation| August 2014
RFconfigurations
8/17/2019 TMO 18552-B WCDMA 9712 LR OD and 9711 LR ID Cabinet Layout _ 14w34.pdf
http://slidepdf.com/reader/full/tmo-18552-b-wcdma-9712-lr-od-and-9711-lr-id-cabinet-layout-14w34pdf 11/82
All Rights Reserved © Alcatel-Lucent 2006
971x LR ID or OD Cabinet - Common Module Presentation
11 | 9712 LR OD Cabinet Presentation| August 2014
Alarm module Eamo for LR OD / Eami for LR ID
The lightRadio outdoor / indoor cabinet supports up to 32 User
alarm module with EAMo / EAmi. The eAMo doesn’t consume 13HU or 21HU useful space.
EAMo IS available only in case of LTE or WCDMA BBU present in theconfiguration.
PCM Lightning Protection
The lightRadio OD/ID cabinet supports a LPPCM in WCDMA for IUBprotection on PCM.
Power Supply Unit for AC variant
The lightRadio OD/ID cabinet supports one PSU in AC variant,located at the bottom of the cabinet.
Rack Battery in the small/compact cabinet
The lightRadio Outdoor cabinet supports as an option one or twobattery (compact only) rack
8/17/2019 TMO 18552-B WCDMA 9712 LR OD and 9711 LR ID Cabinet Layout _ 14w34.pdf
http://slidepdf.com/reader/full/tmo-18552-b-wcdma-9712-lr-od-and-9711-lr-id-cabinet-layout-14w34pdf 12/82
All Rights Reserved © Alcatel-Lucent 2006
971x LR ID or OD Cabinet - Common Module Presentation
NOTE: For more information refer to Product Description or MOPG or PEI (Engineering rules) of the dedicated Product
12 | 9712 LR OD Cabinet Presentation| August 2014
GPS kit
The lightRadio outdoor cabinet supports as an option a GPS kit or a GPS splitter to distribute the GPS signal to one or two
LTE BBU.
The GPS option is provided with surge protections, an internal cabling for up to two BBU (with a splitter) and an externalinstallation items.
The GPS-RF is currently not supported in WCDMA and GSM techno.
ROUTER B/H
The lightRadio outdoor cabinet supports as an option the Alcatel-Lucent routers: 7705 SAR-F, 7705 SAR-8 and 7210 SAS-D ETR.Note that the 7705 SAR-F is an MD product, no more orderable.
8/17/2019 TMO 18552-B WCDMA 9712 LR OD and 9711 LR ID Cabinet Layout _ 14w34.pdf
http://slidepdf.com/reader/full/tmo-18552-b-wcdma-9712-lr-od-and-9711-lr-id-cabinet-layout-14w34pdf 13/82
All Rights Reserved © Alcatel-Lucent 2006
971x LR ID or OD Cabinet - Common Module Presentation
NOTE: For more information refer to Product Description or MOPG or PEI (Engineering rules) of the dedicated Product
13 | 9712 LR OD Cabinet Presentation| August 2014
RADIO MODULE BAND VIII – MC-TRDU 900MHZ (GSM/WCDMA)
The TRDU2×60 900 acts as an indoor Remote Radio Head which can be mounted in whatever type of cabinet.
It’s a “self contained unit” 19 inch form factor, which means it comes along with its own temperature control tosupervise the hot swappable fans on the front side It is completely EMI/EMC compliant and therefore anadditional cabinet is for this purpose not required.
It can support simultaneous GSM + WCDMA (LR13.3 SW release), or GSM only, or in the future WCDMA only.
The support of two technologies is done on the same physical device but with a clear separation per antenna
MC-TRDU 900 provisioning rules
MC-TRDU 900 1 PA 2G/1 PA 3G (FRS150821/119185 – LR13.3G/LR13.3W)
In Multi techno mode, each MC-TRDU 900 must be connected to BBU WCDMA and SUMX19. A maximum of 3 MC-TRDU Multi techno can be configured in this release.
The MC-TRDU are connected on the ports HSO1-3 of the SUMx19.
MC-TRDU 900 in 2G mode only (FRS126090 – LR13.3G)
An MC-TRDU in 2G mode is only connected to the SUMX19.
A maximum of 3 MC-TRDU will be connected to the SUMX19.
MC-TRDU 900 in 3G mode w/o dependency to 2G (FRS132085 / LR14.2.3W)
Up to LR14.2W SW release the MC-TRDU 900 cannot work in 3G only mode (SUMX19 is requested)
Brackets mounted on the module are not expected for Outdoor cabinet, but only for Indoor.
In the lightRadio outdoor cabinet, brackets already mounted on the module must be remove and replace by anew front bracket.
Additionally, two supports side brackets have to be mounted below module
8/17/2019 TMO 18552-B WCDMA 9712 LR OD and 9711 LR ID Cabinet Layout _ 14w34.pdf
http://slidepdf.com/reader/full/tmo-18552-b-wcdma-9712-lr-od-and-9711-lr-id-cabinet-layout-14w34pdf 14/82
All Rights Reserved © Alcatel-Lucent 2006
971x LR ID or OD Cabinet - Common Module Presentation
NOTE: For more information refer to Product Description or MOPG or PEI (Engineering rules) of the dedicated Product
14 | 9712 LR OD Cabinet Presentation| August 2014
RADIO MODULE BAND III – MC-TRDU 1800MHZ (GSM/LTE)
The TRDU2×60 is acts as an indoor Remote Radio Head which can be mounted in whatever type of cabinet.
It’s a “self contained unit” 19 inch form factor, which means it comes along with its own temperature control tosupervise the hot swappable fans on the front side It is completely EMI/EMC compliant and therefore anadditional cabinet is for this purpose not required.
The TRDU2x60 contains 2 amplifiers to realize two transmit paths and allow MIMO operation.
The filter and duplexer device is build in as well as AISG and RET support.
All connectivity is realized on the front side such as power, RF and data and external alarm connections.
The supply voltage is 48V DC.
One TRDU2x60 serves one sector. It encompasses all the functionalities as of a RRH
MC-TRDU 1800 provisioning rules
MC-TRDU 1800 Multi techno support (each PA dedicated to one techno only)
In Multi techno mode, each MC-TRDU 1800 must be connected to BBU LTE and SUMX19.
A maximum of 3 MC-TRDU in Multi techno mode can be configured in this release.
The MC-TRDU are connected on the ports HSO1-3 of the SUMx19.
MC-TRDU 1800 in 4G mode
An MC-TRDU in 4G mode is only connected to the BBU LTE.
A maximum of 6 MC-TRDU will be connected to the BBU LTE (3 MCTRDU at the introduction, 6 is software releasedependent).
MC-TRDU 1800 in 2G mode only (LR13.3G-125176) The MC-TRDU in 2G mode is only connected to the SUMX19.
Up to 3 MC-TRDU can be connected in star configuration to the SUMx19. Ring-chain feature is supported in 2G, ifmore than 3 MC-TRDU are required.
8/17/2019 TMO 18552-B WCDMA 9712 LR OD and 9711 LR ID Cabinet Layout _ 14w34.pdf
http://slidepdf.com/reader/full/tmo-18552-b-wcdma-9712-lr-od-and-9711-lr-id-cabinet-layout-14w34pdf 15/82
All Rights Reserved © Alcatel-Lucent 2006
971x LR ID or OD Cabinet - Common Module Presentation
NOTE: For more information refer to Product Description or MOPG or PEI (Engineering rules) of the dedicated Product
15 | 9712 LR OD Cabinet Presentation| August 2014
RADIO MODULE BAND XX – TRDU 2X60 800 MHZ
This section provides an overview of the LTE Transmitter Receiver Duplexer Unit (TRDU) twin Tx 60W 800MHz
(3GPP Band 20) covering the full 3GPP UL/DL band DL 791-821MHz / UL 832-862MHz with an instantaneousbandwidth of 30MHz, product from Alcatel-Lucent.
Official naming of the product: Alcatel-Lucent TRDU 2x60W 800 MHz In the document the short name is used:TRDU2x60-08
TRDU2x60-08 overviewAll connectivity is realized on the front side
of the TRDU such as:· 1 x 2W2 2-pin D-sub connector for -48VDC power,
· 1 x CPRI port (CPRI-PRI or CPRI1) to connect to BBU(s),
· 1 x CPRI port (CPRI-SEC or CPRI2) for TRDU daisy-chain (HW ready)
· 2 x 7/16 DIN RF ports connected to antennas, · 4 x DIN 1.0/2.3 Ffor TX/RX monitoring (2 TX, 2 RX)
· 1 x RJ45 port for troubleshooting
· 1 x ALD port for RETA or TMA through AISG2.0 connection
TRDU2x60-08 provisioning rules
Up to 3 TRDU 800 (one per sector) can be installed inside the lightradio indoor cabinet and connected to theBBU LTE FDD in star configuration.
8/17/2019 TMO 18552-B WCDMA 9712 LR OD and 9711 LR ID Cabinet Layout _ 14w34.pdf
http://slidepdf.com/reader/full/tmo-18552-b-wcdma-9712-lr-od-and-9711-lr-id-cabinet-layout-14w34pdf 16/82
All Rights Reserved © Alcatel-Lucent 2006
971x LR ID or OD Cabinet - Common Module Presentation
NOTE: For more information refer to Product Description or MOPG or PEI (Engineering rules) of the dedicated Product
16 | 9712 LR OD Cabinet Presentation| August 2014
RADIO MODULE BAND VII – 2600 MHZ
The TRDU2x60 product is a single sector self-contained radio module, including two radio-transceivers, two
power-amplifiers, a dual-duplexer unit, and a CPRI interface for connection to the LTE BBU.The 2600 MHz TRDU supports two Tx paths with 60W per path.
The TRDU 2600 MHz is supported in the lightRadio cabinet inside the 9412 Compact enclosure.
The 9412 Compact enclosure supports 3 x TRDU, the Fan tray and the LTE BBU.
All connectivity is realized on the front side of the TRDU such as:
· 1 x 2W2 socket connector for power,
· 2 x CPRI ports to connect to BBU(s),
· 2 x 7/16 RF ports connected to antennas,
· 2 x SMA for Auxillary RF for antenna-sharing
· 1 x AISG to support one ALD (RET or TMA through AISG2.0 connection)
8/17/2019 TMO 18552-B WCDMA 9712 LR OD and 9711 LR ID Cabinet Layout _ 14w34.pdf
http://slidepdf.com/reader/full/tmo-18552-b-wcdma-9712-lr-od-and-9711-lr-id-cabinet-layout-14w34pdf 17/82
All Rights Reserved © Alcatel-Lucent 2006
971x LR ID or OD Cabinet - Common Module Presentation
NOTE: For more information refer to Product Description or MOPG or PEI (Engineering rules) of the dedicated Product
17 | 9712 LR OD Cabinet Presentation| August 2014
RADIO MODULE BAND I - TRDU 60W 2100 MHZ
The TRDU is a single radio module 2100MHz, with the function of radio transceiver, power amplifier, low noise
amplifier and duplexer and two CPRI interfaces for connection to the WCDMA BBU or for TRDU daisy-chaining.All the TRDU interfaces are in front of the module.
The TRDU is mounted in a subrack TRDU, supporting up to 6 TRDUs and its own cooling system.
The TRDU subrack system is an assembly of three main items:
· One mechanical sub rack assembly supporting up to six TRDUs
· One TRCU (TRDU sub rack Cooling Unit) module
· One or two TRDU ICO: The TRDU ICO is the Interconnection module for the TRDU and TRCU power input.
Each TRDU ICO is powered by -48VDC from the PDP and delivered this power to three TRDU modules + TRCU (forthe first TRDU ICO).
8/17/2019 TMO 18552-B WCDMA 9712 LR OD and 9711 LR ID Cabinet Layout _ 14w34.pdf
http://slidepdf.com/reader/full/tmo-18552-b-wcdma-9712-lr-od-and-9711-lr-id-cabinet-layout-14w34pdf 18/82
All Rights Reserved © Alcatel-Lucent 2006
971x LR ID or OD Cabinet - Common Module Presentation
NOTE: For more information refer to Product Description or MOPG or PEI (Engineering rules) of the dedicated Product
18 | 9712 LR OD Cabinet Presentation| August 2014
RADIO MODULE BAND I – TRDU 2X80W 2100 MHZ
The TRDU 2x80 2100MHz Band 1 is a 2HU “self contained unit” 19 inch form factor, which means it comes along with its
own temperature control to supervise the hot swappable fans on the front side It is completely EMI/EMC compliant andtherefore an additional cabinet is for this purpose not required.
The TRDU has two RF transmitters, four receivers, packaged in a single shelf-mounted module.
The TRDU is rated for 2x67W nominal long-term average power at the TRDU output (to support 2x60W at EAC).
The interfaces of the TRDU include
DC power (-48V),
four antenna connections,
two CPRI ports,
2 TX and
4 RX monitor-only ports,
Ethernet port,
AISG port and
up to two internal Smart Bias-T circuits.
All connections are located on the front faceplate of the TRDU.
The TRDU supports CPRI Rates 2 through 5 (and are HW ready for rate 6).
TRDU 2x80-21 provisioning rules
Up to 3 TRDU 2100 MHz (one per sector) can be installed inside the lightradio outdoor cabinet and connected tothe BBU WCDMA in star configuration.
8/17/2019 TMO 18552-B WCDMA 9712 LR OD and 9711 LR ID Cabinet Layout _ 14w34.pdf
http://slidepdf.com/reader/full/tmo-18552-b-wcdma-9712-lr-od-and-9711-lr-id-cabinet-layout-14w34pdf 19/82
All Rights Reserved © Alcatel-Lucent 2006
971x LR ID or OD Cabinet - Common Module Presentation
NOTE: For more information refer to Product Description or MOPG or PEI (Engineering rules) of the dedicated Product
19 | 9712 LR OD Cabinet Presentation| August 2014
REMOTE RADIO HEAD
Twin RRH
Two types of specific dual PA RRH available, depending on band requirements, used in MIMO case but also in multistandard cases (GSM+UMTS, GSM+LTE).
Twin RRH for 2100 MHz band, intended for UMTS/LTE technology, will support by default MIMO (2xTx and 2xRx).
Similar to a single PA RRH, it has two antenna connectors.
However, in the Twin case, each connector is capable for Tx and Rx simultaneously.
Twin RRH is covered by a dedicated MOPG
MC-RRH
MC-RRH module dual PA available in 900/1800 MHz band variant, intended for GSM/UMTS/LTE technology, will support bydefault MIMO for UMTS and LTE(2xTx and 2xRx).
It offer two antenna connectors, each connector is capable for Tx and Rx simultaneously.
One single sector supported.
MC-RRH module is based on multi carrier power amplifier (SDR) technology, using a single Power Amplifier for severalcarriers.
MC-RRH can run in two operating modes:
· Mono-standard MC-RRH mode, running in a single RAT: either GSM, or UMTS or LTE.
· Multi-standard MC-RRH mode, allows operating simultaneously GSM and 3G; or GSM and LTE band, with one technologyper one power amplifier output, e.g. GSM on PA1 + UMTS on PA2; or GSM on PA1+ LTE on PA2.
MC-RRH is covered by a dedicated MOPG
RRH power cable from lightRadio cabinet
The lightRadio outdoor cabinet is able to power up the RRHs. These cables must be order in this case.
8/17/2019 TMO 18552-B WCDMA 9712 LR OD and 9711 LR ID Cabinet Layout _ 14w34.pdf
http://slidepdf.com/reader/full/tmo-18552-b-wcdma-9712-lr-od-and-9711-lr-id-cabinet-layout-14w34pdf 20/82
All Rights Reserved © Alcatel-Lucent 2006
971x LR ID or OD Cabinet - Common Module Presentation
20 | 9712 LR OD Cabinet Presentation| August 2014
REMOTE MC-TRXThe aim of the feature “remote MC-TRX”, already available in the 9100 Multistandard cabinet is to connect to a WCDMABBU (D2U or D4U) hosting inside the lightRadio cabinet the MC-TRX modules in 3G or MSR mode, installed inside a 2G
cabinet.
In this configuration, the connection between the WCDMA digital controller and the MC-TRX is made with optical fibres.SFP modules have to be installed on each side of the fibre and connected to the MCTRX and to the WCDMA digitalcontroller.
One of the key point of this configuration is the number of cable glands available on the bulkhead interface of thelightRadio cabinet.
Assuming that 3 fibres are required to support a 3 sector configuration with one MCTRX per sector, before proposing asuch configuration, you must ensure, there is the relevant number of cable glands on the bulkhead of each cabinet.
The number of cable glands available on the lightRadio cabinet is dependent of the following factors:
· The Cabinet configuration type has an impact on the bulkhead type (macro or digital bulkheads).
As an example, Conf#7W (digital cabinet) allows up to 18 fibers on the three cable glands of the bulkhead, ;
Conf #6 (Macro cabinet), allows up to 6 fibers on the six cable glands of the bulkhead.
· The number of optical fibers already used for the backhaul interface of the digital controllers (2G/3G/4G)
· The number of optical fibers already used for the RRH connection.
8/17/2019 TMO 18552-B WCDMA 9712 LR OD and 9711 LR ID Cabinet Layout _ 14w34.pdf
http://slidepdf.com/reader/full/tmo-18552-b-wcdma-9712-lr-od-and-9711-lr-id-cabinet-layout-14w34pdf 21/82
All Rights Reserved © Alcatel-Lucent 2006
9712 LR Outdoor Cabinet
Description
8/17/2019 TMO 18552-B WCDMA 9712 LR OD and 9711 LR ID Cabinet Layout _ 14w34.pdf
http://slidepdf.com/reader/full/tmo-18552-b-wcdma-9712-lr-od-and-9711-lr-id-cabinet-layout-14w34pdf 22/82
All Rights Reserved © Alcatel-Lucent 2006
9712 LR Outdoor Cabinet Presentation
NOTE: For more information refer to Product Description or MOPG or PEI (Engineering rules) of the dedicated Product
22 | 9712 LR OD Cabinet Presentation| August 2014
The new designed lightRadio™ Outdoor Cabinet is one single cabinet family for GSM and/or WCDMA and/or LTEwith support for standard 19” equipment.
There are three sizes of outdoor lightRadio™ cabinet, a 13U size (small) and a 21U size (compact), a battery
cabinetThe cabinet family is comprised of stackable elements, as shown in the figure.
The lightRadio cabinet family is being introduced as a multi-technology cabinet to host
lightRadio multi-standard network elements.
The cabinet can be used for BBU with a distributed solution
but it can also be used to house BBU and RF components
to create a legacy solution
– a combination of distributed and traditional solutionis possible.
Within the cabinet certain legacy
components can also be housed.
Various configurations are supported
by the lightRadio cabinet family:
- Batteries + PSU + BBU + internal RF Modules
- Batteries + PSU + BBU + external RRH
- Battery cabinet + small cabinet digital
8/17/2019 TMO 18552-B WCDMA 9712 LR OD and 9711 LR ID Cabinet Layout _ 14w34.pdf
http://slidepdf.com/reader/full/tmo-18552-b-wcdma-9712-lr-od-and-9711-lr-id-cabinet-layout-14w34pdf 23/82
All Rights Reserved © Alcatel-Lucent 2006
9712 LR Outdoor Cabinet Presentation
23 | 9712 LR OD Cabinet Presentation| August 2014
Cabinet Dimensioning
Width
Height
Depth
Width
Height
8/17/2019 TMO 18552-B WCDMA 9712 LR OD and 9711 LR ID Cabinet Layout _ 14w34.pdf
http://slidepdf.com/reader/full/tmo-18552-b-wcdma-9712-lr-od-and-9711-lr-id-cabinet-layout-14w34pdf 24/82
All Rights Reserved © Alcatel-Lucent 2006
9712 LR Outdoor Cabinet Presentation
NOTE: For more information refer to Product Description or MOPG or PEI (Engineering rules) of the dedicated Product
24 | 9712 LR OD Cabinet Presentation| August 2014
Cabinet enclosure
The main characteristics of the cabinets (small or compact) are listed below:
· Hinged front door, which opens toward the left.
· Keyed door latch.
· Four (4) lifting points on top where M12 threaded eye-bolts can be installed.
· The lifting points can also be used for anchoring points when one cabinet is stacked atop another.
· Removable gland plates are mounted in the floor of the cabinet to allow cable connections.
· A choice of two different mounting plinths provides flexibility for cable routing.
· Cable pass-through ports on top of the cabinet, with removable covers, facilitate stacking of cabinets.
· External grounding points are present on both the left and right cabinet sides.
8/17/2019 TMO 18552-B WCDMA 9712 LR OD and 9711 LR ID Cabinet Layout _ 14w34.pdf
http://slidepdf.com/reader/full/tmo-18552-b-wcdma-9712-lr-od-and-9711-lr-id-cabinet-layout-14w34pdf 25/82
All Rights Reserved © Alcatel-Lucent 2006
9712 LR Outdoor Cabinet Presentation
NOTE: For more information refer to Product Description or MOPG or PEI (Engineering rules) of the dedicated Product
25 | 9712 LR OD Cabinet Presentation| August 2014
Bulkhead Interface of the Compact/small cabinet
There are three removable gland plates per configuration on the bottom surface of the cabinet, each of them in
different versions, allowing more than 8 combinations.These gland plates can be used to customize the connector interface for any particular application.
8/17/2019 TMO 18552-B WCDMA 9712 LR OD and 9711 LR ID Cabinet Layout _ 14w34.pdf
http://slidepdf.com/reader/full/tmo-18552-b-wcdma-9712-lr-od-and-9711-lr-id-cabinet-layout-14w34pdf 26/82
All Rights Reserved © Alcatel-Lucent 2006
9712 LR Outdoor Cabinet Presentation
NOTE: For more information refer to Product Description or MOPG or PEI (Engineering rules) of the dedicated Product
26 | 9712 LR OD Cabinet Presentation| August 2014
Cabinet mounting options
The lightRadio™ cabinets have EIA-310-D compliant racks for mounting components.
Movable shelf support brackets are available, and can be mounted where needed to provide physical support forcomponents.
A plinth provides cable routing flexibility, allowing the cables to exit from the sides or the rear depending on theindividual site conditions.
There are two sizes of plinth, a basic (small) size and an extended size.
· The basic mounting plinth is 150 mm high; only used with the digital cabinet (distributed configurations), RoWregions only.
· The extended plinth is 275 mm high; always used with NAR cabinets and in the other regions with Macrocabinets (internal radio modules).
THERMAL MANAGEMENT AND AIR FLOW
8/17/2019 TMO 18552-B WCDMA 9712 LR OD and 9711 LR ID Cabinet Layout _ 14w34.pdf
http://slidepdf.com/reader/full/tmo-18552-b-wcdma-9712-lr-od-and-9711-lr-id-cabinet-layout-14w34pdf 27/82
8/17/2019 TMO 18552-B WCDMA 9712 LR OD and 9711 LR ID Cabinet Layout _ 14w34.pdf
http://slidepdf.com/reader/full/tmo-18552-b-wcdma-9712-lr-od-and-9711-lr-id-cabinet-layout-14w34pdf 28/82
All Rights Reserved © Alcatel-Lucent 2006
9712 LR Outdoor Cabinet Presentation
NOTE: For more information refer to Product Description or MOPG or PEI (Engineering rules) of the dedicated Product
28 | 9712 LR OD Cabinet Presentation| August 2014
Heaters for Compact / Small Cabinet
The heater assembly for the lightRadio cabinet is installed on the inner surface of the front door of the
lightRadio cabinet.Mounting hardware for the heater is included with the heater.
· For DC cabinet the heater is 700W, 54VDC
· For AC cabinet, the heater is 950W, 230VAC.
The heaters are optional:
· Small cabinet can be equipped with 1 heater (AC or DC)
· Compact cabinet can be equipped with:
• One heater AC for a Compact AC
• Up to two heaters DC for a Compact DC.
8/17/2019 TMO 18552-B WCDMA 9712 LR OD and 9711 LR ID Cabinet Layout _ 14w34.pdf
http://slidepdf.com/reader/full/tmo-18552-b-wcdma-9712-lr-od-and-9711-lr-id-cabinet-layout-14w34pdf 29/82
All Rights Reserved © Alcatel-Lucent 2006
9712 LR Outdoor Cabinet Presentation
NOTE: For more information refer to Product Description or MOPG or PEI (Engineering rules) of the dedicated Product
29 | 9712 LR OD Cabinet Presentation| August 2014
LightRadio Cabinet Controller (LRCC)
The LRCC is an Alcatel Lucent proprietary design, installed on the inner surface of the front door of LR cabinet,
which has several functions:· Monitor the internal cabinet temperature from two thermistors.
· Control speed of cabinet fans based on cabinet temperature.
· Control heater(s) regulation for AC and DC, based on cabinet temperature.
· Monitor cabinet alarms from intrusion switches,
· Monitor alarms from air pressure alarm switch.
· Monitor alarms from fan failure,
· Monitor alarms from over temperature and under temperature
· Monitor alarms from LTE TRDU rack fan.
In case there is no TRDU inside the cabinet, an RJ-45 Alarm termination must be installed on the LRCC “TRDUFan alarm input”.
On the LRCC, the Deep Switch must be configurated in accordance with the cabinet configuration.
8/17/2019 TMO 18552-B WCDMA 9712 LR OD and 9711 LR ID Cabinet Layout _ 14w34.pdf
http://slidepdf.com/reader/full/tmo-18552-b-wcdma-9712-lr-od-and-9711-lr-id-cabinet-layout-14w34pdf 30/82
All Rights Reserved © Alcatel-Lucent 2006
9712 LR Outdoor Cabinet Presentation
NOTE: For more information refer to Product Description or MOPG or PEI (Engineering rules) of the dedicated Product
30 | 9712 LR OD Cabinet Presentation| August 2014
*FAN SPEED PROFILE: As soon as Radio Module 19” form factor are present in the configuration, a specific LRCCsetting has to be selected in order to use the Fan Speed: profile 6.
Each LRCC setting is individually configurable(ex: Stacked cabinet with
Small cabinet hosting Radio Module 19” modules = setting profile 6 +
Compact cabinet hosting digital modules = setting ETSI profile 5).
Note that the LRCC is part of the order code of the assembly cabinet.
8/17/2019 TMO 18552-B WCDMA 9712 LR OD and 9711 LR ID Cabinet Layout _ 14w34.pdf
http://slidepdf.com/reader/full/tmo-18552-b-wcdma-9712-lr-od-and-9711-lr-id-cabinet-layout-14w34pdf 31/82
All Rights Reserved © Alcatel-Lucent 2006
9712 LR Outdoor Cabinet Presentation
NOTE: For more information refer to Product Description or MOPG or PEI (Engineering rules) of the dedicated Product
31 | 9712 LR OD Cabinet Presentation| August 2014
POWER DISTRIBUTION
AC breaker
The AC breaker and terminal block provide a disconnect device to the main incoming AC power line in thecabinet through three breakers.
The Input Switch block supports either the AC configuration for three phases (without the bridge), or for theSingle phase (with the 3pts bridge mounted on L1,L2 & L3).
The AC breaker kit is composed with:
· 1 x AC Switch 4 poles
· 1 x bridge 3 positions (for AC single phase configuration)
· 1 x ground terminal block· 3 x ground studs M6
· 4 x Nuts for the mounting plate
8/17/2019 TMO 18552-B WCDMA 9712 LR OD and 9711 LR ID Cabinet Layout _ 14w34.pdf
http://slidepdf.com/reader/full/tmo-18552-b-wcdma-9712-lr-od-and-9711-lr-id-cabinet-layout-14w34pdf 32/82
All Rights Reserved © Alcatel-Lucent 2006
9712 LR Outdoor Cabinet Presentation
NOTE: For more information refer to Product Description or MOPG or PEI (Engineering rules) of the dedicated Product
32 | 9712 LR OD Cabinet Presentation| August 2014
Power Distribution Panel (PDP)Each small or compact cabinet has a dedicated space for mounting a DC Power Distribution Panel (PDP).
The PDP is located to the left of the main component rack mounting and thus does not consume any of thevertical rack space.
· The PDP for the 13U cabinet has eight (8) circuit breaker 25A positions and one additional circuit breaker 80Awith terminals to feed RRHs or a small cabinet stacked.
· The PDP for the 21U cabinet has eleven (11) circuit breaker positions (1x30A, 9x25A, 1x70A), and oneadditional circuit breaker 80A with terminals to feed RRHs or a small cabinet stacked.
70A is dedicated to Small stacked cabinet
80A for RRH (and eventually 80A and 70A for RRH).
Note that the PDP is part of the order code of the assy cabinet.
8/17/2019 TMO 18552-B WCDMA 9712 LR OD and 9711 LR ID Cabinet Layout _ 14w34.pdf
http://slidepdf.com/reader/full/tmo-18552-b-wcdma-9712-lr-od-and-9711-lr-id-cabinet-layout-14w34pdf 33/82
All Rights Reserved © Alcatel-Lucent 2006
9712 LR Outdoor Cabinet Presentation
NOTE: For more information refer to Product Description or MOPG or PEI (Engineering rules) of the dedicated Product
33 | 9712 LR OD Cabinet Presentation| August 2014
DC Power Distribution in the cabinet
A diagram of the DC power distribution for the Small (13U) and Compact (21U) cabinet is shown in the next
figure.The PDP for the small or compact cabinet is rated at 150 Amps, although it must be borne in mind that:
· in the case of DC small cabinet, the main limitation to keep in mind is the 75A rating of the DC input filter
· the small cabinet can dissipate a maximum heat load of 2000 Watts,
· the compact cabinet can dissipate a maximum heat load of 4000 Watts.
8/17/2019 TMO 18552-B WCDMA 9712 LR OD and 9711 LR ID Cabinet Layout _ 14w34.pdf
http://slidepdf.com/reader/full/tmo-18552-b-wcdma-9712-lr-od-and-9711-lr-id-cabinet-layout-14w34pdf 34/82
All Rights Reserved © Alcatel-Lucent 2006
9712 LR Outdoor Cabinet Presentation
NOTE: For more information refer to Product Description or MOPG or PEI (Engineering rules) of the dedicated Product
34 | 9712 LR OD Cabinet Presentation| August 2014
Optional AC power input
The Compact cabinet can accept a 2U rack mountable rectifier in the rack mount space.
The input is 230V AC, 50/60 Hz, single or 3-phase; with an -48V DC output capacity of 6 kW.
Replaceable rectifier module can allow for N+1 configurations. (3KW rectifier is not validated yet).
8/17/2019 TMO 18552-B WCDMA 9712 LR OD and 9711 LR ID Cabinet Layout _ 14w34.pdf
http://slidepdf.com/reader/full/tmo-18552-b-wcdma-9712-lr-od-and-9711-lr-id-cabinet-layout-14w34pdf 35/82
All Rights Reserved © Alcatel-Lucent 2006
9712 LR Outdoor Cabinet Presentation
NOTE: For more information refer to Product Description or MOPG or PEI (Engineering rules) of the dedicated Product
35 | 9712 LR OD Cabinet Presentation| August 2014
Optional 19” rack mounted battery
Batteries can be mounted for AC cabinets. The AC cabinets can handle up to two 19” rack mounted string of
batteries.The battery strings will be installed at the bottom of the cabinet within the 19” rack - 7U height.
Up to 2 battery racks (90Ah) can be installed in the lightRadio Compact cabinet; only one battery rack in thelightRadio small cabinet.
If additional batteries are required an additional cabinet dedicated to housing battery strings is recommended.
This option doesn’t apply to the battery cabinet, which is battery specific.
Optional RRH feed through LR OD AC cabinet
The AC cabinet Small or Compact can be used to power RRH, if the internal power allows it. In that case onebreaker 80A on the PDP is available to connect the RRHs:
· through an auxiliary PDP located inside the cabinet or
· through an external DC surge box.
8/17/2019 TMO 18552-B WCDMA 9712 LR OD and 9711 LR ID Cabinet Layout _ 14w34.pdf
http://slidepdf.com/reader/full/tmo-18552-b-wcdma-9712-lr-od-and-9711-lr-id-cabinet-layout-14w34pdf 36/82
All Rights Reserved © Alcatel-Lucent 2006
9712 LR Outdoor Cabinet Presentation
NOTE: For more information refer to Product Description or MOPG or PEI (Engineering rules) of the dedicated Product
36 | 9712 LR OD Cabinet Presentation| August 2014
Auxiliary PDP
The auxiliary PDP is a distribution panel that provides -48V to supply and protects up to 6 RRHs assets.
The -48V is coming from PDP already present in the pre-cabled cabinet.The auxiliary PDP is composed of:
1 x input terminal block 80A => input from PDP of the cabinet
1 surge protector (integrated box)
6 x 20A circuit breakers associated with 6 output terminal blocks => to connect up to 6 RRHs modules.
8/17/2019 TMO 18552-B WCDMA 9712 LR OD and 9711 LR ID Cabinet Layout _ 14w34.pdf
http://slidepdf.com/reader/full/tmo-18552-b-wcdma-9712-lr-od-and-9711-lr-id-cabinet-layout-14w34pdf 37/82
All Rights Reserved © Alcatel-Lucent 2006
9712 LR Outdoor Cabinet Presentation
NOTE: For more information refer to Product Description or MOPG or PEI (Engineering rules) of the dedicated Product
37 | 9712 LR OD Cabinet Presentation| August 2014
External DC surge box
This protection box is installed outside the cabinet, at 5 meters maximum distance of the cabinet.
It can be fixed on a wall or on a pole with a specific pole mounting kit.
The connectivity is the following:
Provision a pair of DC capacitor 75A on the LR OD bulkhead
Connect the DC capacitor 75A to the PDP small or compact (breaker 80A) or breaker 75A (Compact only)
Connect one external DC box to the DC capacitors (up to 2 DC box can be connected per DC capacitor. Studyto be done case by case).
Up to 3 RRH connected per DC surge box
8/17/2019 TMO 18552-B WCDMA 9712 LR OD and 9711 LR ID Cabinet Layout _ 14w34.pdf
http://slidepdf.com/reader/full/tmo-18552-b-wcdma-9712-lr-od-and-9711-lr-id-cabinet-layout-14w34pdf 38/82
All Rights Reserved © Alcatel-Lucent 2006
9712 LR Outdoor Cabinet Presentation
NOTE: For more information refer to Product Description or MOPG or PEI (Engineering rules) of the dedicated Product
38 | 9712 LR OD Cabinet Presentation| August 2014
9712 LR OD CONFIGURATION SUMMARY
8/17/2019 TMO 18552-B WCDMA 9712 LR OD and 9711 LR ID Cabinet Layout _ 14w34.pdf
http://slidepdf.com/reader/full/tmo-18552-b-wcdma-9712-lr-od-and-9711-lr-id-cabinet-layout-14w34pdf 39/82
All Rights Reserved © Alcatel-Lucent 2006
9712 LR Outdoor Cabinet Presentation
39 | 9712 LR OD Cabinet Presentation| August 2014
TRDU LTE inside lightRadio outdoor cabinet TRDU side bracket in LR OD cabinet
8/17/2019 TMO 18552-B WCDMA 9712 LR OD and 9711 LR ID Cabinet Layout _ 14w34.pdf
http://slidepdf.com/reader/full/tmo-18552-b-wcdma-9712-lr-od-and-9711-lr-id-cabinet-layout-14w34pdf 40/82
All Rights Reserved © Alcatel-Lucent 2006
9712 LR Outdoor Cabinet
Site Preparation
8/17/2019 TMO 18552-B WCDMA 9712 LR OD and 9711 LR ID Cabinet Layout _ 14w34.pdf
http://slidepdf.com/reader/full/tmo-18552-b-wcdma-9712-lr-od-and-9711-lr-id-cabinet-layout-14w34pdf 41/82
All Rights Reserved © Alcatel-Lucent 2006
9712 LR OD Cabinet Site Preparation Guidelines 3MN-01655-0001-RJZZA
41 | 9712 LR OD Cabinet Presentation| August 2014
Basic site preparation requirements and cabinet footprints
Outdoor environment Heat dissipation
8/17/2019 TMO 18552-B WCDMA 9712 LR OD and 9711 LR ID Cabinet Layout _ 14w34.pdf
http://slidepdf.com/reader/full/tmo-18552-b-wcdma-9712-lr-od-and-9711-lr-id-cabinet-layout-14w34pdf 42/82
All Rights Reserved © Alcatel-Lucent 2006
9712 LR OD Cabinet Site Preparation Guidelines 3MN-01655-0001-RJZZA
42 | 9712 LR OD Cabinet Presentation| August 2014
Basic site preparation requirements and cabinet footprintsInstallation Clearance – Left Wall Installation Clearance – Right Wall
8/17/2019 TMO 18552-B WCDMA 9712 LR OD and 9711 LR ID Cabinet Layout _ 14w34.pdf
http://slidepdf.com/reader/full/tmo-18552-b-wcdma-9712-lr-od-and-9711-lr-id-cabinet-layout-14w34pdf 43/82
All Rights Reserved © Alcatel-Lucent 2006
9712 LR OD Cabinet Site Preparation Guidelines 3MN-01655-0001-RJZZA
43 | 9712 LR OD Cabinet Presentation| August 2014
Electrical power requirements
Power consumption (estimated) DC feeders and connection interface
RRH PDP
The DC power supply of RRH can be provided by the cabinetusing the Auxiliary RRH PDP to supply up to 6 RRHs. In 9 RRHs
is used, the DC power supply of the third RRH bands can be
provided by the cabinet using the specific output 70A of themain PDP plus a second Auxiliary RRH PDP.
Electrical rating for the 9712 DC cabinet
Electrical rating for the 9712 AC cabinet
~208-240V~50/60Hz,45A
8/17/2019 TMO 18552-B WCDMA 9712 LR OD and 9711 LR ID Cabinet Layout _ 14w34.pdf
http://slidepdf.com/reader/full/tmo-18552-b-wcdma-9712-lr-od-and-9711-lr-id-cabinet-layout-14w34pdf 44/82
All Rights Reserved © Alcatel-Lucent 2006
9712 LR OD Cabinet Site Preparation Guidelines 3MN-01655-0001-RJZZA
44 | 9712 LR OD Cabinet Presentation| August 2014
Electrical power requirements
DC Power (Configuration3)
8/17/2019 TMO 18552-B WCDMA 9712 LR OD and 9711 LR ID Cabinet Layout _ 14w34.pdf
http://slidepdf.com/reader/full/tmo-18552-b-wcdma-9712-lr-od-and-9711-lr-id-cabinet-layout-14w34pdf 45/82
All Rights Reserved © Alcatel-Lucent 2006
9712 LR OD Cabinet Site Preparation Guidelines 3MN-01655-0001-RJZZA
45 | 9712 LR OD Cabinet Presentation| August 2014
Electrical power requirements
AC Power (Configuration3)
AC input requirements (cabinets with integrated power)
8/17/2019 TMO 18552-B WCDMA 9712 LR OD and 9711 LR ID Cabinet Layout _ 14w34.pdf
http://slidepdf.com/reader/full/tmo-18552-b-wcdma-9712-lr-od-and-9711-lr-id-cabinet-layout-14w34pdf 46/82
All Rights Reserved © Alcatel-Lucent 2006
9712 LR Outdoor Cabinet
Layout Description
8/17/2019 TMO 18552-B WCDMA 9712 LR OD and 9711 LR ID Cabinet Layout _ 14w34.pdf
http://slidepdf.com/reader/full/tmo-18552-b-wcdma-9712-lr-od-and-9711-lr-id-cabinet-layout-14w34pdf 47/82
All Rights Reserved © Alcatel-Lucent 2006
9712 LR OD Small Cabinet Configuration
NOTE: For more information refer to Product Description or MOPG or PEI (Engineering rules) of the dedicated Product
47 | 9711 LR ID Cabinet Presentation | August 2014
Configuration #1 - Layout
Configuration #4B/4C/4D - Layout
Configuration #8B - Layout
8/17/2019 TMO 18552-B WCDMA 9712 LR OD and 9711 LR ID Cabinet Layout _ 14w34.pdf
http://slidepdf.com/reader/full/tmo-18552-b-wcdma-9712-lr-od-and-9711-lr-id-cabinet-layout-14w34pdf 48/82
All Rights Reserved © Alcatel-Lucent 2006
9712 LR OD Compact Cabinet Configuration
NOTE: For more information refer to Product Description or MOPG or PEI (Engineering rules) of the dedicated Product
48 | 9711 LR ID Cabinet Presentation | August 2014
Configuration #4X - Layout
Configuration #7
- Layout
8/17/2019 TMO 18552-B WCDMA 9712 LR OD and 9711 LR ID Cabinet Layout _ 14w34.pdf
http://slidepdf.com/reader/full/tmo-18552-b-wcdma-9712-lr-od-and-9711-lr-id-cabinet-layout-14w34pdf 49/82
All Rights Reserved © Alcatel-Lucent 2006
9712 LR OD Stacked Cabinet Configuration
49 | 9711 LR ID Cabinet Presentation | August 2014
Configuration #6 - Layout Config. #6A - Layout
8/17/2019 TMO 18552-B WCDMA 9712 LR OD and 9711 LR ID Cabinet Layout _ 14w34.pdf
http://slidepdf.com/reader/full/tmo-18552-b-wcdma-9712-lr-od-and-9711-lr-id-cabinet-layout-14w34pdf 50/82
All Rights Reserved © Alcatel-Lucent 2006
9712 LR OD Stacked Cabinet Configuration
50 | 9711 LR ID Cabinet Presentation | August 2014
Config. #5 - Layout Config. #11 - Layout Config. #9C - Layout
8/17/2019 TMO 18552-B WCDMA 9712 LR OD and 9711 LR ID Cabinet Layout _ 14w34.pdf
http://slidepdf.com/reader/full/tmo-18552-b-wcdma-9712-lr-od-and-9711-lr-id-cabinet-layout-14w34pdf 51/82
All Rights Reserved © Alcatel-Lucent 2006
9711 LR Indoor Cabinet
Description
8/17/2019 TMO 18552-B WCDMA 9712 LR OD and 9711 LR ID Cabinet Layout _ 14w34.pdf
http://slidepdf.com/reader/full/tmo-18552-b-wcdma-9712-lr-od-and-9711-lr-id-cabinet-layout-14w34pdf 52/82
All Rights Reserved © Alcatel-Lucent 2006
9711 LR Indoor Cabinet Presentation
NOTE: For more information refer to Product Description or MOPG or PEI (Engineering rules) of the dedicated Product
52 | 9711 LR ID Cabinet Presentation | August 2014
Physical description
The LightRadio indoor cabinet is intended for use in indoor
weather protected temperature-controlled environments forEMEA, Asia-Pacific and latin America (ETSI) market applications.
8/17/2019 TMO 18552-B WCDMA 9712 LR OD and 9711 LR ID Cabinet Layout _ 14w34.pdf
http://slidepdf.com/reader/full/tmo-18552-b-wcdma-9712-lr-od-and-9711-lr-id-cabinet-layout-14w34pdf 53/82
All Rights Reserved © Alcatel-Lucent 2006
9711 LR Indoor Cabinet Presentation
NOTE: For more information refer to Product Description or MOPG or PEI (Engineering rules) of the dedicated Product
53 | 9711 LR ID Cabinet Presentation | August 2014
Cabinet Dimensioning
PDP is included in the 38HU and 23HU (reducing the real useful height for equipments).
8/17/2019 TMO 18552-B WCDMA 9712 LR OD and 9711 LR ID Cabinet Layout _ 14w34.pdf
http://slidepdf.com/reader/full/tmo-18552-b-wcdma-9712-lr-od-and-9711-lr-id-cabinet-layout-14w34pdf 54/82
All Rights Reserved © Alcatel-Lucent 2006
9711 LR Indoor Cabinet Presentation
NOTE: For more information refer to Product Description or MOPG or PEI (Engineering rules) of the dedicated Product
54 | 9711 LR ID Cabinet Presentation | August 2014
lightradio Compact Indoorcabinet with modulepositioning
8/17/2019 TMO 18552-B WCDMA 9712 LR OD and 9711 LR ID Cabinet Layout _ 14w34.pdf
http://slidepdf.com/reader/full/tmo-18552-b-wcdma-9712-lr-od-and-9711-lr-id-cabinet-layout-14w34pdf 55/82
All Rights Reserved © Alcatel-Lucent 2006
9711 LR Indoor Cabinet Presentation
55 | 9711 LR ID Cabinet Presentation | August 2014
Bulkhead Interface Panel
The LightRadio Indoor cabinet can be delivered with 3 types of Bulkhead Interface panels, depending to the targetconfiguration:
Bulkheadinterface panelfor SUMX19,3G/4Gconfiguration
Bulkheadinterface panelfor SUMX legacy,3G/4Gconfiguration
Bulkheadinterface panelfor Chinaconfiguration
with SUMx legacy (to supportMCTRX or TRX) and 4G.
with SUMx legacy (to support MC-TRX radio module) and 3G/4G.
with SUMx19, and 3G/4G
8/17/2019 TMO 18552-B WCDMA 9712 LR OD and 9711 LR ID Cabinet Layout _ 14w34.pdf
http://slidepdf.com/reader/full/tmo-18552-b-wcdma-9712-lr-od-and-9711-lr-id-cabinet-layout-14w34pdf 56/82
All Rights Reserved © Alcatel-Lucent 2006
9711 LR Indoor Cabinet Presentation
NOTE: For more information refer to Product Description or MOPG or PEI (Engineering rules) of the dedicated Product
56 | 9711 LR ID Cabinet Presentation | August 2014
Alarm and options bulkhead
The Alarm and Options bulkhead is located on the left side ofbulkhead interface panel.
Cable path through for optical links
Configuration required max.
3 RRH bands with up to 9 CPRI optical outputs.
The optical interface link is done through conductive plasticgrommet D=37mm or feed through devices using 2 RF holes.
This is also to be used for optical GE interface.
External alarms connection4 x Dsub HD 15pts (for up to 32 external alarms managed by eAMiB)
AISG connection
3 x 8 pins circular connector cut-out are available to support AISG with TRDU 800MHz In LTE (no integrated bias tee).
GPS / Microwave( for future use)
2 x N connectors cut-outs
8/17/2019 TMO 18552-B WCDMA 9712 LR OD and 9711 LR ID Cabinet Layout _ 14w34.pdf
http://slidepdf.com/reader/full/tmo-18552-b-wcdma-9712-lr-od-and-9711-lr-id-cabinet-layout-14w34pdf 57/82
All Rights Reserved © Alcatel-Lucent 2006
9711 LR Indoor Cabinet Presentation
NOTE: For more information refer to Product Description or MOPG or PEI (Engineering rules) of the dedicated Product
57 | 9711 LR ID Cabinet Presentation | August 2014
PCM and Ethernet bulkhead
The PCM and Ethernet panel is located on the middle of the bulkhead interface panel.
This bulkhead is not provided in the configurations with SUMX legacy.It’s used in addition to the “Alarm and option bulkhead”, for PCM connectivity in WCDMA and backhaul GE electricalconnectivity in 2G, 3G and 4G.
This bulkhead is designed to support:
· One D-sub 37-pts, supporting up to 8 PCM for WCDMA. This connector is internally connected directly to the WCDMA BBUor to the LPPCM option.
· Two D-sub 9-pts, supporting 2 x 2 PCM for GSM. These connectors were planed to connect the PCM to the SUMX19 inch.In fact the PCM cable is directly connected to the SUMX19 inch through a CFT kit on the antenna holes. In other word,these 2 connectors are never used.
· Eight RJ-45 Gender-coupler, for electrical backhaul connectivity to SUMX19 (feature Abis over IP), BBU WCDMA (featureIUB over IP) and LTE.
8/17/2019 TMO 18552-B WCDMA 9712 LR OD and 9711 LR ID Cabinet Layout _ 14w34.pdf
http://slidepdf.com/reader/full/tmo-18552-b-wcdma-9712-lr-od-and-9711-lr-id-cabinet-layout-14w34pdf 58/82
All Rights Reserved © Alcatel-Lucent 2006
9711 LR Indoor Cabinet Presentation
58 | 9711 LR ID Cabinet Presentation | August 2014
Rules for Ethernet port cabling on “PCM and Ethernet” bulkhead
WCDMA: d2UV3 or d4UV3 single nodeB
If 1 GE electrical connection is required on 1 x 3G BBU: cabling has to be done on ETH1
If 2 x GE electrical connection is required on 1 x 3G BBU: cabling has to be done on both ETH1 and ETH2; feature lagEthernet is required on the single 3G BBU.
WCDMA: d4UV3 dual nodeB
If 1 GE electrical connection is required on each CCM-U (CCM-A and CCM-B): cabling has to be done on both ETH1 (CCM-A)and ETH2 (CCM-B)
GSM
If 1 GE electrical connection is required on 1 x SUMx19”: cabling has to be done on ETH3If 1 GE electrical connection is required on 2 x SUMx19”: cabling has to be done on ETH3 for first SUMx19”, and on ETH4for 2nd SUMx19”
If 2 x GE electrical connection is required on 1 x SUMx19”: cabling to be done on both ETH3 and ETH4
(feature lag Ethernet is required on a single SUMx19”; for future)
LTE FDD
If 1 GE electrical connection is required on 1 x 4G BBU FDD: cabling has to be done on ETH5
If 2 x GE electrical connection is required on 1 x 4G BBU FDD: cabling has to be done on both ETH5 and ETH6
(feature lag Ethernet is required on a single 4G BBU; for future).
LTE TDD
If 1 GE electrical connection is required on 1 x 4G BBU TDD: cabling has to be done on ETH7
If 2 x GE electrical connection is required on 1 x 4G BBU TDD: cabling has to be done on both ETH7 and ETH8
(feature lag Ethernet is required on a single 4G BBU; for future).
8/17/2019 TMO 18552-B WCDMA 9712 LR OD and 9711 LR ID Cabinet Layout _ 14w34.pdf
http://slidepdf.com/reader/full/tmo-18552-b-wcdma-9712-lr-od-and-9711-lr-id-cabinet-layout-14w34pdf 59/82
All Rights Reserved © Alcatel-Lucent 2006
9711 LR Indoor Cabinet Presentation
NOTE: For more information refer to Product Description or MOPG or PEI (Engineering rules) of the dedicated Product
59 | 9711 LR ID Cabinet Presentation | August 2014
Power Supply and Circuit Breaker Area DCBR-5 (China market)
This bulkhead is available only with the lightRadio Indoor for China market, configuration #6.
The power supply input/output connectors and circuit breakers are located on DCBR5 on the right-hand side.The external power supply inputs/outputs to/from the cabinet are located on the power supply and circuit breaker areaDCBR5.
There are:
· Two DC filter connectors; one for the 0 V input and one for the -48VDC input.
· Six DC circuit breakers protect the cabinet equipment from overload. Each subrack power supply is protected by aseparate circuit breaker.
8/17/2019 TMO 18552-B WCDMA 9712 LR OD and 9711 LR ID Cabinet Layout _ 14w34.pdf
http://slidepdf.com/reader/full/tmo-18552-b-wcdma-9712-lr-od-and-9711-lr-id-cabinet-layout-14w34pdf 60/82
All Rights Reserved © Alcatel-Lucent 2006
9711 LR Indoor Cabinet Presentation
NOTE: For more information refer to Product Description or MOPG or PEI (Engineering rules) of the dedicated Product
60 | 9711 LR ID Cabinet Presentation | August 2014
DC Input Interface panel
The DC Input Interface Panel is part of the lightRadio indoor cabinet in every configuration, except in configuration #6,for China market.
The input for the DC supply cables are on the top of the cabinet.
DC cabinet:
DC Input: 2 x 200A DC feed through filters needed for -48 input and 0V return.
AC cabinet (for future):
AC input: For 6 kW PSU, in single phase a 3 x 6mm2 shielded cable is needed (30A @ 230VAC). directly connected onPSU with shielded cable gland on top of the cabinet.
DC input: 2 x 80A DC feed through filters needed for AC Version with specific RRH DC filter panel .
8/17/2019 TMO 18552-B WCDMA 9712 LR OD and 9711 LR ID Cabinet Layout _ 14w34.pdf
http://slidepdf.com/reader/full/tmo-18552-b-wcdma-9712-lr-od-and-9711-lr-id-cabinet-layout-14w34pdf 61/82
All Rights Reserved © Alcatel-Lucent 2006
9711 LR Indoor Cabinet Presentation
NOTE: For more information refer to Product Description or MOPG or PEI (Engineering rules) of the dedicated Product
61 | 9711 LR ID Cabinet Presentation | August 2014
GSM alarm interface panel (XIBM)
If MC-TRX 2G are installed in the LightRadio indoor cabinet, the Alarm and Option bulkhead is replaced by the XIBM board
, to connect the 2G alarms towards the 2G management system.
Abis interface (MSCA)
If MC-TRX 2G are installed in the LightRadio indoor cabinet, the backhaul interface panel is replaced by the MSCA board ,to connect the Abis PCM towards the SUMx legacy.
8/17/2019 TMO 18552-B WCDMA 9712 LR OD and 9711 LR ID Cabinet Layout _ 14w34.pdf
http://slidepdf.com/reader/full/tmo-18552-b-wcdma-9712-lr-od-and-9711-lr-id-cabinet-layout-14w34pdf 62/82
All Rights Reserved © Alcatel-Lucent 2006
9711 LR Indoor Cabinet Presentation
NOTE: For more information refer to Product Description or MOPG or PEI (Engineering rules) of the dedicated Product
62 | 9711 LR ID Cabinet Presentation | August 2014
Multistandard and ETHMI Bulkhead
If MC-TRX 2G are installed in the LightRadio indoor cabinet,
o the Multistandard bulkhead can be delivered to connect the IUB PCM interface + up to 2 electrical FE/GE of the 3G part.
o If the backhaul of the WCDMA part is through GE and if more than 2 ethernet ports are required by the digitalcontrollers installed inside the cabinet, the Multistandard bulkhead is replaced by the ETHMI bulkhead.
Rules for Ethernet port cabling on
“Multistandard” bulkhead
This bulkhead is used with the configurations:
C#6X, C#24, C#4A, C#25A
Config 6X: only 1 BBU LTE
1st RJ45 to be used if 1 GE electrical is required
1st and 2nd to be used if lag Ethernet required
Config 24: only 1 BBU WCDMA
1st RJ45 to be used if 1 GE electrical is required
1st and 2nd to be used if lag Ethernet required
Config 4A: only 1 BBU WCDMA
1st RJ45 to be used if 1 GE electrical is required 1st and 2nd to be used if lag Ethernet requiredConfig 25A: up to 3 BBUs possible As there is only 2 RJ45 available, if each BBU needs at least one GE port, there is anissue.
Depending on the customer config, best would be to say:
1st BBU (or master BBU) to be connected to Multi-standard bulkhead (same rules as above), and then other BBUs will haveto pass their GE electrical IUB links through CFT Kit.
8/17/2019 TMO 18552-B WCDMA 9712 LR OD and 9711 LR ID Cabinet Layout _ 14w34.pdf
http://slidepdf.com/reader/full/tmo-18552-b-wcdma-9712-lr-od-and-9711-lr-id-cabinet-layout-14w34pdf 63/82
All Rights Reserved © Alcatel-Lucent 2006
9711 LR Indoor Cabinet Presentation
NOTE: For more information refer to Product Description or MOPG or PEI (Engineering rules) of the dedicated Product
63 | 9711 LR ID Cabinet Presentation | August 2014
Rectifier shelf for LightRadio Indoor AC variant (for future)
The LightRadio Indoor cabinet can be powered by AC or DC external power source.
For the AC version of the LightRadio Indoor cabinet, rectifiers are required.
The rectifier shelf is a 2U rack mountable unit that can provide up to 6000 W using N+1 redundancy.
The rectifier shelf requires 230 VAC 50/60 Hz power input, single or 3 phase connection.
Output power is at -48VDC.
A single rectifier shelf per indoor LightRadio cabinet is allowed.
CoolingThe Indoor lightRadio Cabinet uses a convectional cooling system with the installed equipment pushing air in any neededdirection.
The overall cabinet airflow is from bottom to top.
To this effect the Indoor lightRadio Cabinet will use a mid-mount approach
meaning the equipment mounting ears will be in the middle (front to back)
of the equipment.
In the Indoor lightRadio Cabinets the digital equipment will be installed
to create a right to left airflow.Legacy RF equipment will be installed to generate a bottom to top airflow.
The MCTRDUs will have front to back airflow.
In some case a top fan may be required for medium or large configurations
which include many RF components.
8/17/2019 TMO 18552-B WCDMA 9712 LR OD and 9711 LR ID Cabinet Layout _ 14w34.pdf
http://slidepdf.com/reader/full/tmo-18552-b-wcdma-9712-lr-od-and-9711-lr-id-cabinet-layout-14w34pdf 64/82
All Rights Reserved © Alcatel-Lucent 2006
9711 LR Indoor Cabinet Presentation
NOTE: For more information refer to Product Description or MOPG or PEI (Engineering rules) of the dedicated Product
64 | 9711 LR ID Cabinet Presentation | August 2014
RF interfaces
Up to 18 antenna connectors 7/16 are available on the top of the cabinet.
With one or two bands inside the cabinet, the number of RF connectors is sufficient.As soon as a third band is present inside the cabinet, two antenna boxes are required in order to increment the numberof holes on top of the cabinet.
8/17/2019 TMO 18552-B WCDMA 9712 LR OD and 9711 LR ID Cabinet Layout _ 14w34.pdf
http://slidepdf.com/reader/full/tmo-18552-b-wcdma-9712-lr-od-and-9711-lr-id-cabinet-layout-14w34pdf 65/82
All Rights Reserved © Alcatel-Lucent 2006
9711 LR Indoor Cabinet Presentation
NOTE: For more information refer to Product Description or MOPG or PEI (Engineering rules) of the dedicated Product
65 | 9711 LR ID Cabinet Presentation | August 2014
Lightradio cabinet alarm collection
The following cabinet alarms can be generated in the lightRadio cabinet indoor.
These alarms are for both LR DC and LR AC version:· Door intrusion · Top fan unit failure
· TRDU LTE fan tray alarm X2 (two alarms available for cases where two shelves LTE are needed).
The following power related alarms can be generated for the primary rectifier shelf if present (AC variant):
· Mains failure ( total lost of mains voltage, not combined with non-urgent and urgent alarms)
· Urgent alarm (failure of more than one rectifier or failure of one rectifier in 1+1 configuration)
· Non-urgent alarm (failure of one rectifier)
· Battery failure (high temperature, voltage imbalance)
· Low battery capacity
· PSU control module failure
· AC in OVP failure (surge protection).
These alarms are collected by eAMiB when 3G or 4G is master.
For 2G only, only top fan unit alarm is managed through external alarm (other cabinet alarms not managed) and PSUalarms managed through SNMP.
8/17/2019 TMO 18552-B WCDMA 9712 LR OD and 9711 LR ID Cabinet Layout _ 14w34.pdf
http://slidepdf.com/reader/full/tmo-18552-b-wcdma-9712-lr-od-and-9711-lr-id-cabinet-layout-14w34pdf 66/82
All Rights Reserved © Alcatel-Lucent 2006
9711 LR Indoor Cabinet Presentation
NOTE: For more information refer to Product Description or MOPG or PEI (Engineering rules) of the dedicated Product
66 | 9711 LR ID Cabinet Presentation | August 2014
DC POWER DISTRIBUTION PANEL
A DC input Panel and a Power Distribution Panel (PDP) is used in the global market, for lightRadio cabinet hosting theMultistandard radio modules and the controllers for the three technologies:
The DC input Panel receives the -48VDC from outside the cabinet and distributes the -48VDC directly to the PDP; it islocated on the right side of the connection Area (refer to chapter 1).
The PDP includes DC breakers and connectors towards individual DC-powered functional units.
The PDP is mounted horizontally at the top of the cabinet, under the connection area and takes 1,5 HU from the availablespace of the lightRadio indoor cabinet.
· For the LightRadio Compact cabinet a PDP 13 breakers is available:
o Connector 1: breaker 10A – Top fan option and XIBM if any
o Connector 2 to 9: breaker 25A - any BBU (d2U, d4U, SUMx 19), MC-TRDU, LTE TRDU, TRDU ICO
o Connector 10 to 13: breaker 30A - SUMx19+MC-TRDU, LTE TRDU
· For the lightradio small cabinet a PDP 8 breakers is available:
o Connector 1: breaker 10A – Top fan option and XIBM if any
o Connector 2 to 6: breaker 25A - digital controller (d2U, d4U, SUMx 19)
o Connector 7 & 8: breaker 30A - SUMx 19 + BBU, TRDU ICO, STASR rack
8/17/2019 TMO 18552-B WCDMA 9712 LR OD and 9711 LR ID Cabinet Layout _ 14w34.pdf
http://slidepdf.com/reader/full/tmo-18552-b-wcdma-9712-lr-od-and-9711-lr-id-cabinet-layout-14w34pdf 67/82
All Rights Reserved © Alcatel-Lucent 2006
9711 LR Indoor Cabinet Presentation
NOTE: For more information refer to Product Description or MOPG or PEI (Engineering rules) of the dedicated Product
67 | 9711 LR ID Cabinet Presentation | August 2014
DC breaker 5 (DCBR-5)
A DC input and breaker panel is used in China market for :
· lightRadio compact cabinet hosting MC-TRX or TWIN TRX, inside a STASR subrack.· lightRadio small cabinet configuration BBU hostelling: configuration #11B
· lightRadio small cabinet configuration TRDU 2100: configuration #9B
This DC breaker Panel is located on the right side of the connection Area.
From this breaker panel:
· Up to 5 breakers 30A for: STASR, digital or radio module
· one breaker 15A for Top FAN and External Alarm Managt
8/17/2019 TMO 18552-B WCDMA 9712 LR OD and 9711 LR ID Cabinet Layout _ 14w34.pdf
http://slidepdf.com/reader/full/tmo-18552-b-wcdma-9712-lr-od-and-9711-lr-id-cabinet-layout-14w34pdf 68/82
All Rights Reserved © Alcatel-Lucent 2006
9711 LR Indoor Cabinet Presentation
NOTE: For more information refer to Product Description or MOPG or PEI (Engineering rules) of the dedicated Product
68 | 9711 LR ID Cabinet Presentation | August 2014
Power Distribution Panel
The following table summarizes the type of power distribution through the configurations:
8/17/2019 TMO 18552-B WCDMA 9712 LR OD and 9711 LR ID Cabinet Layout _ 14w34.pdf
http://slidepdf.com/reader/full/tmo-18552-b-wcdma-9712-lr-od-and-9711-lr-id-cabinet-layout-14w34pdf 69/82
All Rights Reserved © Alcatel-Lucent 2006
9711 LR Indoor Cabinet Presentation
NOTE: For more information refer to Product Description or MOPG or PEI (Engineering rules) of the dedicated Product
69 | 9711 LR ID Cabinet Presentation | August 2014
Top Fan Assembly
Top Fan provisioning rules in the Compact cabinet
Configuration with MC-TRX6 Top Fan is required if more than 6 MCTRX inside the cabinet
Configuration with MCTRDU / TRDU self contained (new TRDU)
6 Top fan: a soon as MCTRDU are present in the cabinet
Configuration with TRDU shelf
no Top fan (as soon as there is no MCTRDU)
Top Fan provisioning rules in the Small cabinet
Configuration with BBU + Radio modules
6 Top Fan with radio modules inside the small cabinet
Configuration with BBU only
0 Top Fan: Conf 11B (for type 3 & 4, not yet qualified by R&D)
6 Top Fan: Conf 11A, as soon two BBU in horizontal position
d b
8/17/2019 TMO 18552-B WCDMA 9712 LR OD and 9711 LR ID Cabinet Layout _ 14w34.pdf
http://slidepdf.com/reader/full/tmo-18552-b-wcdma-9712-lr-od-and-9711-lr-id-cabinet-layout-14w34pdf 70/82
All Rights Reserved © Alcatel-Lucent 2006
9711 LR Indoor Cabinet Presentation
NOTE: For more information refer to Product Description or MOPG or PEI (Engineering rules) of the dedicated Product
70 | 9711 LR ID Cabinet Presentation | August 2014
CFT KIT: cable feed through
Kit-CFT cable feed through contains two 7/16 cable feed through.
If SUMX legacy is used in the lightRadio indoor cabinet, then CFT kit is needed for optical links.
If the Alarm and options bulkhead is provided, the optical links pass through this bulkhead, CFT kit for optical links is notrequired.
9711 LR I d C bi P i
8/17/2019 TMO 18552-B WCDMA 9712 LR OD and 9711 LR ID Cabinet Layout _ 14w34.pdf
http://slidepdf.com/reader/full/tmo-18552-b-wcdma-9712-lr-od-and-9711-lr-id-cabinet-layout-14w34pdf 71/82
All Rights Reserved © Alcatel-Lucent 2006
9711 LR Indoor Cabinet Presentation
NOTE: For more information refer to Product Description or MOPG or PEI (Engineering rules) of the dedicated Product
71 | 9711 LR ID Cabinet Presentation | August 2014
9711 LIGHTRADIO INDOOR CONFIGURATION SUMMARY
8/17/2019 TMO 18552-B WCDMA 9712 LR OD and 9711 LR ID Cabinet Layout _ 14w34.pdf
http://slidepdf.com/reader/full/tmo-18552-b-wcdma-9712-lr-od-and-9711-lr-id-cabinet-layout-14w34pdf 72/82
All Rights Reserved © Alcatel-Lucent 2006
9711 LR Indoor Cabinet
Site Preparation
9711 LR ID C bi t Sit P ti G id li 3MN 01654 0001 RJZZA
8/17/2019 TMO 18552-B WCDMA 9712 LR OD and 9711 LR ID Cabinet Layout _ 14w34.pdf
http://slidepdf.com/reader/full/tmo-18552-b-wcdma-9712-lr-od-and-9711-lr-id-cabinet-layout-14w34pdf 73/82
All Rights Reserved © Alcatel-Lucent 2006
9711 LR ID Cabinet Site Preparation Guidelines 3MN-01654-0001-RJZZA
73 | 9712 LR OD Cabinet Presentation| August 2014
Basic site preparation requirements and cabinet footprints
Indoor environment Heat dissipation
9711 LR ID Cabinet Site Preparation Guidelines 3MN 01654 0001 RJZZA
8/17/2019 TMO 18552-B WCDMA 9712 LR OD and 9711 LR ID Cabinet Layout _ 14w34.pdf
http://slidepdf.com/reader/full/tmo-18552-b-wcdma-9712-lr-od-and-9711-lr-id-cabinet-layout-14w34pdf 74/82
All Rights Reserved © Alcatel-Lucent 2006
9711 LR ID Cabinet Site Preparation Guidelines 3MN-01654-0001-RJZZA
74 | 9712 LR OD Cabinet Presentation| August 2014
Basic site preparation requirements and cabinet footprintsInstallation Clearance
Fixation anchor kit for concrete floorFixation anchor kit for raised floor
9711 LR ID Cabinet Site Preparation Guidelines 3MN 01654 0001 RJZZA
8/17/2019 TMO 18552-B WCDMA 9712 LR OD and 9711 LR ID Cabinet Layout _ 14w34.pdf
http://slidepdf.com/reader/full/tmo-18552-b-wcdma-9712-lr-od-and-9711-lr-id-cabinet-layout-14w34pdf 75/82
All Rights Reserved © Alcatel-Lucent 2006
9711 LR ID Cabinet Site Preparation Guidelines 3MN-01654-0001-RJZZA
75 | 9712 LR OD Cabinet Presentation| August 2014
Electrical power requirements
Power consumption (estimated) DC feeders and connection interface
8/17/2019 TMO 18552-B WCDMA 9712 LR OD and 9711 LR ID Cabinet Layout _ 14w34.pdf
http://slidepdf.com/reader/full/tmo-18552-b-wcdma-9712-lr-od-and-9711-lr-id-cabinet-layout-14w34pdf 76/82
All Rights Reserved © Alcatel-Lucent 2006
9711 LR Indoor Cabinet
Layout Description
9711 LR ID Compact (38 HU) Cabinet Configuration
8/17/2019 TMO 18552-B WCDMA 9712 LR OD and 9711 LR ID Cabinet Layout _ 14w34.pdf
http://slidepdf.com/reader/full/tmo-18552-b-wcdma-9712-lr-od-and-9711-lr-id-cabinet-layout-14w34pdf 77/82
All Rights Reserved © Alcatel-Lucent 2006
9711 LR ID Compact (38 HU) Cabinet Configuration
NOTE: For more information refer to Product Description or MOPG or PEI (Engineering rules) of the dedicated Product
77 | 9711 LR ID Cabinet Presentation | August 2014
Configuration #4A - Layout Config. #6A Config. #6B
9711 LR ID Compact (38 HU) Cabinet Configuration
8/17/2019 TMO 18552-B WCDMA 9712 LR OD and 9711 LR ID Cabinet Layout _ 14w34.pdf
http://slidepdf.com/reader/full/tmo-18552-b-wcdma-9712-lr-od-and-9711-lr-id-cabinet-layout-14w34pdf 78/82
All Rights Reserved © Alcatel-Lucent 2006
9711 LR ID Compact (38 HU) Cabinet Configuration
NOTE: For more information refer to Product Description or MOPG or PEI (Engineering rules) of the dedicated Product
78 | 9711 LR ID Cabinet Presentation | August 2014
Configuration #8A / 8C - Layout Config. #8B
9711 LR ID Compact (38 HU) Cabinet Configuration
8/17/2019 TMO 18552-B WCDMA 9712 LR OD and 9711 LR ID Cabinet Layout _ 14w34.pdf
http://slidepdf.com/reader/full/tmo-18552-b-wcdma-9712-lr-od-and-9711-lr-id-cabinet-layout-14w34pdf 79/82
All Rights Reserved © Alcatel-Lucent 2006
9711 LR ID Compact (38 HU) Cabinet Configuration
NOTE: For more information refer to Product Description or MOPG or PEI (Engineering rules) of the dedicated Product
79 | 9711 LR ID Cabinet Presentation | August 2014
Configuration #16 - Layout Config. #26 - Layout
9711 LR ID Small (23 HU) Cabinet Configuration
8/17/2019 TMO 18552-B WCDMA 9712 LR OD and 9711 LR ID Cabinet Layout _ 14w34.pdf
http://slidepdf.com/reader/full/tmo-18552-b-wcdma-9712-lr-od-and-9711-lr-id-cabinet-layout-14w34pdf 80/82
All Rights Reserved © Alcatel-Lucent 2006
9711 LR ID Small (23 HU) Cabinet Configuration
NOTE: For more information refer to Product Description or MOPG or PEI (Engineering rules) of the dedicated Product
80 | 9711 LR ID Cabinet Presentation | August 2014
Configuration #9A - Layout Config. #9B - Layout
9711 LR ID Small (23 HU) Cabinet Configuration
8/17/2019 TMO 18552-B WCDMA 9712 LR OD and 9711 LR ID Cabinet Layout _ 14w34.pdf
http://slidepdf.com/reader/full/tmo-18552-b-wcdma-9712-lr-od-and-9711-lr-id-cabinet-layout-14w34pdf 81/82
All Rights Reserved © Alcatel-Lucent 2006
9711 LR ID Small (23 HU) Cabinet Configuration
NOTE: For more information refer to Product Description or MOPG or PEI (Engineering rules) of the dedicated Product
81 | 9711 LR ID Cabinet Presentation | August 2014
Config. #11A - Layout Config. #11B - Layout Config. #24 - Layout
8/17/2019 TMO 18552-B WCDMA 9712 LR OD and 9711 LR ID Cabinet Layout _ 14w34.pdf
http://slidepdf.com/reader/full/tmo-18552-b-wcdma-9712-lr-od-and-9711-lr-id-cabinet-layout-14w34pdf 82/82
www.alcatel-lucent.com