DescriptionRolls of high-density, ISOVER ULTIMATE wool, reinforced with a galvanised steel mesh; · ULTIMATE Protect Wired Mat 4.0 not covered.· ULTIMATE Protect Wired Mat 4.0 Alu1 the external facing
is covered with reinforced aluminium foil which acts as a vapour barrier.
ApplicationsBecause of its exceptional thermal and acoustic properties and excellent fire-safety behaviour, the ULTIMATE Protect range is the ideal solution for external insulation, capable of providing fire resistance in:· Networks of circular section metal air-distribution ducts
in thermal installations in buildings, both residential and industrial.
Technical properties
Advantages· Maximum protection against fire, in accordance with EN 13501-1.
· Fire resistant in section metal air-distribution ducts . In accordance with EN 13501-3, EN 1366-1 and EN 1366-8.
· Quick and easy installation.· Up to 65% lighter than conventional products.· Maximum compressibility, highly reliable and adaptable.· Easy to transport.· Optimal thermal and acoustic performance with low thickness solutions.
· Meets the highest safety standard guidelines· Inert material, inhospitable for micro-organisms.· Sustainable product. 100% recyclable. Recycled material > 50%
PresentationThickness
d (mm)Length
l (m)Width b (m)
m2/package
m2/pallet
m2/truck load
30 10.00
0.60
12.00 216.00 4.752
40 7.50 9.00 162.00 3.564
60 6.00 7.20 129.60 2.851
70 5.00 6.00 108.00 2.376
80 4.00 4.80 86.40 1.900
90 3.30 3.96 71.28 1.568
100 3.00 3.60 64.80 1.426
120 2.50 3.00 54.00 1.188
ULTIMATE PROTECT WIRED MAT 4.0/4.0 ALU1 BlackFire protection in circular metal ducts.
Thicknessd, mm
Designation codeISOVER solution
ULTIMATE ProtectEN 823 EN 14303
30-120 MW-EN 14303-T2-ST(+)400Wired Mat 4.0
Wired Mat 4.0 Alu1
Installation GuideConsult the guidelines in the Protect Assembly Manual.Additional information available at: www.isover.es
i→o = interior, o→i = exterior, i↔o = both. ho = horizontal, ve = vertical, ve and ho = both
Construimos tu Futuro
+34 901 33 22 11
www.isover.es
www.isover-aislamiento-tecnico.es
@ISOVERes
isoveresISOVERaislamientoISOVERaislamiento
Sain
t G
obai
n Is
over
Ibér
ica,
S.L
. res
erve
s th
e ri
ght
to m
odif
y, t
otal
ly o
r p
arti
ally
an
d w
ith
out
pri
or n
otifi
cati
on, t
he
info
rmat
ion
con
tain
ed h
erei
n. L
ikew
ise,
th
e ab
sen
ce o
f u
nin
ten
tion
al e
rror
s ca
nn
ot b
e gu
aran
teed
. 11/
04/1
6
Insulation thickness needed (Both fire scenarios: interior and exterior)
Type of ductFire-resistance classification Duct
orientationEI 60 EI 90 EI 120
Multisector extraction and
ventilation75 100 120
Both (Horizontal and Vertical)
Symbol Parameter Icon Units Value Standard
lD
Thermal conductivity declared as a function of temperature
W/m·K (°C)
0,031 (10)
EN 12667 EN 12939
0,035 (50)0,040 (100)0,047 (150)0,054(200)0,072 (300)0,096 (400)
Sound absorption coefficient a
w1,00 EN 11654
Air flow resistance(measurement on non-faced product)
AFR
60 EN 29053
Reaction to fire Euroclass A1 EN 13501-1EN 15715
Fire resistance - From EI15 to EI120 EN 1366
ST Maximum operating temperature °C 400 EN 14706
MUMineral wool: water-vapour diffusion resistance,m
- 1 EN 12086
Z Facing: water-vapour diffusion resistance m2•h•Pa/mg
MU1 (4,0)EN 12086
MV2 (4.0 Alu1)
MVThe vapour diffusion-equivalent air layer thickness, Sd
m 200 EN 12086
Certification
Qualitéde
l'air
inté
rieur
· Calidad aire interior ·QualityInterior•Qualité
del'a
irin
térie
ur· Calidad aire interior ·Q
ualityInterior•
Qualitéde
l'air
inté
rieur
· Calidad aire interior ·QualityInterior•
Qualitéde
l'air
inté
rieur
· Calidad aire interior ·QualityInterior•
Qualitéde
l'air
inté
rieur
· Calidad aire interior ·QualityInterior•