19
MOORTHY ASSOCIATES (MOOVSEN) Submitted By MOORTHY OVSN

Fire protection in thermal power station

Embed Size (px)

DESCRIPTION

Fire protection systems to be considered in different areas of thermal power plants

Citation preview

Page 1: Fire protection in thermal power station

MOORTHY ASSOCIATES(MOOVSEN)

Submitted ByMOORTHY OVSN

Page 2: Fire protection in thermal power station

• FIRE PROTECTION..... A Brief Overview• FIRE PROTECTION…. Survey, Design &

Execution• THERMAL POWER PLANT……Fire

Risks • TYPES OF PROTECTION

RECOMENDED

Page 3: Fire protection in thermal power station

SCEMATIC VIEW OF THERMAL POWER PLANT

Page 4: Fire protection in thermal power station
Page 5: Fire protection in thermal power station

• Fire Audit / Survey to be conducted.

• Fire Risk, Load and Hazard to be indentified.

• Recommended protection to be Identified through TAC/NBC/IS Guide Lines.

• Preparation of drawings, calculations, Quantities, Specifications and Estimates etc to be done.

FIRE PROTECTION..... A Brief Overview

Page 6: Fire protection in thermal power station

Coal yard High hazardous area :

Fire Risk : Class A Fire Best extinguishing agent is water.

Automatic Extinguishing is crit ical and expensive.

Manual Protection to be Instal led:

Water Hydrant system as per TAC/NBC to be Instal led .

Page 7: Fire protection in thermal power station

Coal Conveyor High hazardous area :Fire Risk : Class A Fire Best extinguishing agent is water.Automatic Extinguishing to be Installed:Manual Protection to be also to be Provided:High Velocity Water Spray system as per TAC/NBC to be Installed .Detection: LHS OR QUORTZOID BULBAtomization: Deluge / Electrical

COAL CONVEYOR

Page 8: Fire protection in thermal power station

Boiler medium hazardous area :Fire Risk : Class A Fire Best extinguishing agent is water.Automatic Extinguishing to be Installed:Manual Protection to be also to be Provided:High Velocity Water Spray system as per TAC/NBC to be Installed .Detection: LHS OR QUORTZOID BULBAtomization: Deluge / Electrical

Page 9: Fire protection in thermal power station

TG (TURBINE GENARATOR)

Turbine Medium hazardous area :Fire Risk : Class B and C Fire Best extinguishing agent is Foam / Co2 / PowderAutomatic Early warningSmoke detectionsystem to be Installed:Portable Equipment CO2 / DCP also to be Provided:Foam based Medium Velocity Water Spray system as per TAC/NBC to be Installed to lube oil tanks.Detection: QUORTZOID BULBAtomization: Deluge

Page 10: Fire protection in thermal power station

Cable Gallery Medium hazardous area :Fire Risk : Class B and C Fire Best extinguishing agent is Foam / Co2 / PowderAutomatic Early warningSmoke detectionsystem to be Installed:Portable Equipment CO2 / DCP also to be Provided:High Velocity Water Spray system as per TAC/NBC to be Installed to lube oil tanks.Detection: QUORTZOID BULBAtomization: Deluge

Page 11: Fire protection in thermal power station

Electrical Panel Medium hazardous area :

Fire Risk : Class B and C Fire Best extinguishing agent is Foam / Co2 / Powder

Automatic Early warningSmoke detectionsystem to be Installed:

Portable Equipment CO2 / DCP also to be Provided:

Page 12: Fire protection in thermal power station

Central Control Room Light hazardous area :

Fire Risk : Class A and C Fire Best extinguishing agent is Co2 / FM 200 / INERGEN

Automatic Early warningSmoke detectionsystem and Clean agent Gas suppression systems to be Installed:Detection: Smoke (Cross zone /addressable analogue )Atomization: Solenoid

Portable Equipment CO2 also to be Provided:

Page 13: Fire protection in thermal power station

TRANSFORMER hazardous area :Fire Risk : Class B and C Best extinguishing agent is High Velocity water.Automatic Extinguishing to be Installed:Manual Protection also to be Provided:High Velocity Water Spray system as per TAC/NBC to be Installed .Detection: LHS OR QUORTZOID BULBAtomization: Deluge / Electrical

Page 14: Fire protection in thermal power station

LDO High hazardous area :Fire Risk : Class B Best extinguishing agent is Foam / Co2 / PowderAutomatic Early warningDetection system to be Installed:Required Capacity Equipment FOAM / DCP also to be Provided:Foam based Medium Velocity Water Spray system as per TAC/NBC to be Installed to lube oil tanks.Detection: LHS / QUORTZOID BULBAtomization: Deluge

Page 15: Fire protection in thermal power station

TRANSFORMER hazardous area :Fire Risk : Class B and C Best extinguishing agent is High Velocity water.Automatic Extinguishing to be Installed:Water Hydrant System to be Provided for Switch yard:High Velocity Water Spray system as per TAC/NBC to be Installed for Transformer.Detection: LHS OR QUORTZOID BULBAtomization: Deluge / ElectricalPortable extinguishers to be provided

Page 16: Fire protection in thermal power station

COMMON FIRE PROTECTION FOR TOTAL PLANT:

EARLY WARNING MANUAL CALL POINT FIRE ALARM SYSTEM

PORTABLE EXTINGUISHERS

WATER HYDRANT SYSTEM

Page 17: Fire protection in thermal power station
Page 18: Fire protection in thermal power station

SYSTEM DESIGN :

MOORTHY ASSOCIATES.Fire Safety consultants09346787388 9908411941

#1046, STREET NO; 2,SOMASUNDAR NAGAR,BAGH AMBERPET,HYDERABABD 500013

Page 19: Fire protection in thermal power station

Thank You