65
teel connection design – reinvent Juraj Šabatka CSO&CFO Genk/Kortrijk 23 November 2016

IDEA StatiCa Seel Connections - seminar Genk/Kortrijk nov 2016

Embed Size (px)

Citation preview

Steel connection design – reinvented

Juraj ŠabatkaCSO&CFO

Genk/Kortrijk23 November 2016

2

IDEA STATICA FOR STRUCTURAL ENGINEERINGDevelopment team with 20 years of experience of making innovative software for structural engineers in more than 40 countries.

2

Engineering software dedicated to structural design and code-check of joints, cross sections, beams and other details.

1000+ desktoplicenses

Software resultsvalidated byuniversities

Linked to 12+CAE/CADprograms

30+ employees15+ resellers

4

1MAKING YOUR PROJECTS SAFE AND CODE COMPLIANT

4

55

CAE PROGRAMSFocus on the model of the whole structure.

66

STRUCTURAL DEFECTSBut the majority of defects is caused by bad design of a particular joint or other detail.

Waste of time

Waste of material

7

IDEA STATICA FOCUSES ON JOINTS AND CONNECTIONS

7

88

IDEA STATICA COMPLEMENTS WHAT YOU HAVE

Whole structure

Structuraldetails

Low resources Big resources

99

IDEA StatiCa is the first one to provide SW for joints and connections with development capacity and professionalism of CAE programs.

10

2THE CHALLENGE

10

1111

WE WANT TO BE ON THE SAFE SIDETo comply with Eurocode, AISC, etc.

1212

STANDARDEasy joint

NON-STANDARDDifficult joint

1313

STANDARDEasy joint

NON-STANDARDDifficult joint

Design books Advanced scientific model

Excel spreadsheet

Estimation

Avoid using the joint

1414

30 %Difficult joint

70 %Easy joint

30 %Easy joint

70 %Difficult joint

NUMBER OF JOINTS TIME SPENT

1515

We are here with a tool to check all structural steel joints in minutes.

16

3SOLUTION

16

1717

ALL TYPES OF JOINTS2D Frames & Trusses Footing & Anchoring 3D Frames & Trusses

1818

DESIGN WITH IDEA STATICA CONNECTION

Stress-strain Buckling Analysis Stiffness Analysis Overall Check

19

Stress-strain Buckling analysis Stiffness analysis Overall check

19

ELECTRICITY TOWER MAST – POLAND

Huge normal force loads the group of bolts eccentrically. Bolts cannot take this.

Rearranging of bolts solved the problem.

2020

Stress-strain Buckling analysis Stiffness analysis Overall check

STEEL WAREHOUSE – GERMANY

Connection fully satisfies all stress/strain checks

But the web of the beam can collapse because of local buckling

Additional stiffener resolved this problem

21

Stress-strain Buckling analysis Stiffness analysis Overall check

21

POWER PLANT – CZECH REPUBLIC

Ovalization of CHS. Stiffness perpendicular to CHS is weaker.

All CHS are welded to one plate. Stiffness is 10x higher.

22

Stress-strain Buckling analysis Stiffness analysis Overall check

22

HEATHROW AIRPORT – UK Connection was not designable with the suggested prescribed EC3 requirements and a more generic analysis approach had to be adopted.

2323

24

TESTIMONIALFRISOMAT

24

“IDEA Connect werkt vlot en snel. Er is geen gebruiksvriendelijker alternatief voorhanden dat toelaat FEM met CBM te combineren.IDEA is gewoon degelijk en goed.”

Prof. Dr. Ir. Luc SchueremansEngineering Manager

2525

Any topology, any loading, in minutes.

26

4CREDIBILITY

26

Verification and validation of the new CBFEM method.

27

COMPONENT BASED FINITE ELEMENT MODEL (CBFEM)The weak point of standard Component method Design guides is that the topology is limited.

27

Component Model Bolted Joint CBFEM model

2828

All standard connections from Eurocode / AISC design guides, calculated with the same results.

2929

Complex FEA analytical models were compared with IDEA. Same results.

3030

VERIFICATION – COMPLEX TOPOLOGIESTailor-made design models created in various software.Live testing. All studies published.Two university teams spent over 3 years on this.

31

COOPERATION WITH UNIVERSITIES = VERIFIED SOLUTION

31

ORDER TODAY

32

There is sophisticated method inside. It was verified and transformed into a tool how to create joints.

32

33

REAL-LIFE MANUFACTURING OPERATIONS

33

34

TESTIMONIALOOSTINGH STAALBOUW KATWIJK

34

Alexander van Beelen

“Geeft beter en ook nieuw inzicht in de krachtswerking in verbindingen. Rapportage mag nog watverbeterd worden.”

35

5WORKFLOW

35

3636

BIM INTERFACE – CAD PROGRAMSTekla Structures and Advance Steel.

Node Selection in AS Input of Load Effects Check EN / AISC

3737

BIM INTERFACE – FEA PROGRAMSRobot, SAP 2000, SCIA Engineer, RFEM, AxisVM etc. (Buildsoft Diamonds coming)

Node Selection in RSA Design of Connection Check EN / AISC

3838

IDEA StatiCa would not build such strong links without having strong relationships with the key players in our industry.

3939

PARTNERSHIPS

40

6

40

CUSTOMER EXPERIENCE

4141

CLIENTS

4242

BENELUX

43

TESTIMONIALSTAALBOUWKUNDIG ADVIESBURO VAN ODENHOVEN

43

Marcel van Odenhoven

“Idea Connection is een zeer behulpzaam pakket voor het modelleren van een breed scala van verbindingen in staalconstructies. Het modelleren en interpreteren van de resultaten vraagt inzicht in de krachtswerking binnen een knoop en gaat gelijk op met de complexiteit van de verbinding.”

4444

600Licenses around the world150 Tekla users bought it already

Tool needs to… Allow efficient workflows through

interoperability Be simple to learn and use Be fully supported by codes and validated

theory Be used for concept through to detailed

design

Arup use of IDEA StatiCa Connection

10 years ago….

TeklaDrawing Model

RhinoTransition Model

ExcelLoad Input

D3 PlotStress checks

Excel/VBWeld checks

ANSAMeshing

Nastran Analysis

GSAGlobal Analysis

Modelling, Analysis, Design, Fabrication

…..Now

Original model (days) IDEA StatiCa (in minutes)

Forensic analysis

Arup use of IDEA StatiCa Connection

Arup use of IDEA StatiCa Connection

Arup use of IDEA StatiCa Connection

Arup use of IDEA StatiCa Connection

Arup use of IDEA StatiCa Connection

Arup use of IDEA StatiCa Connection

ARUP and IDEA StatiCa at Autodesk University, Las Vegas, 2016

58

7

58

REPORTING, LOCALISATION,CUSTOMIZATION

5959

REPORTINGWe support Eurocode and AISC.Various sets of material types, cross-sections, bolts, etc.Different types of reports.Schemes of drawings.

6060

OUTPUT REPORTThree types of output reports – one line, 1 page and detailed.

All checks according to Eurocode or AISC displayed and referenced.

61

CUSTOMER PROJECTCEPS – Electricity Tower Masts

61

Special request for manufacturing operations.Developed in 8 weeks.We also provided consultancy

62

CASE STUDYCEPS INVEST

62

Cenek LaubHead of engineering department

“Maintaining and developing electricity network in the Czech Republic is full of challenging tasks. With IDEA StatiCa Connection, joint design got much easier and faster for us.”

6363

We are here with not just a standard application but also with an infrastructure to build a tailor-made solution.

6464

95 %of our customers saw the potential of IDEA StatiCa after 30 minutes of testing.

TRY OUR FREE TRIAL!

It takes 30 minutes to see the potential

Our customers use it for non-standard joints as well as standard ones

The software repays itself on your first project