103
1 Modelling Building Frame with STAAD.Pro & ETABS Rahul Leslie Assistant Director, Buildings Design, DRIQ, Kerala PWD Trivandrum, India Presented by

Modelling Building Frame with STAAD.Pro & ETABS - Rahul Leslie

Embed Size (px)

Citation preview

Page 1: Modelling Building Frame with STAAD.Pro & ETABS - Rahul Leslie

1

Modelling Building Frame with

STAAD.Pro & ETABS

Rahul LeslieAssistant Director,Buildings Design,

DRIQ, Kerala PWDTrivandrum, India

Presented by

Page 2: Modelling Building Frame with STAAD.Pro & ETABS - Rahul Leslie

2

STAAD.Pro & ETABS

Page 3: Modelling Building Frame with STAAD.Pro & ETABS - Rahul Leslie

33

Ground Floor

The example building:

Presented by Rahul LeslieAnalysis & Design of an RC Building in STAAD.Pro & ETABS

Page 4: Modelling Building Frame with STAAD.Pro & ETABS - Rahul Leslie

44

First Floor

The example building:

Storey ht. = 3.6m

Presented by Rahul LeslieAnalysis & Design of an RC Building in STAAD.Pro & ETABS

Page 5: Modelling Building Frame with STAAD.Pro & ETABS - Rahul Leslie

55

Second Floor

The example building:

Storey ht. = 3.6m

Presented by Rahul LeslieAnalysis & Design of an RC Building in STAAD.Pro & ETABS

Page 6: Modelling Building Frame with STAAD.Pro & ETABS - Rahul Leslie

66

Terrace

The example building:

Storey ht. = 3.6m

Presented by Rahul LeslieAnalysis & Design of an RC Building in STAAD.Pro & ETABS

Page 7: Modelling Building Frame with STAAD.Pro & ETABS - Rahul Leslie

7

Initial member size fixing Beams: • Width:

– According to architectural requirements: 20, 23 or 25 cm. – Preferably keep width not less than one-third depth.

• Depth: – Fix an initial size between (span/12) and (span/15). – Choose sizes such as 35, 40, 45, 50, 60, 70, 75, 80 cm or more– This may have to be increased depending on Ast required (from

analysis) at a later stage.

Analysis & Design of an RC Building in STAAD.Pro Presented by Rahul LeslieAnalysis & Design of an RC Building in STAAD.Pro & ETABS

Page 8: Modelling Building Frame with STAAD.Pro & ETABS - Rahul Leslie

8

Initial member size fixing (cont…)Column: • Width:

– What architectural requirements permit: 20, 23, 25 or 30 cm.– Preferably keep width of column grater than that of beams to facilitate

passing of beam reinforcements.– Increase width, wherever possible, to be preferably not less than half

depth. • Depth:

– This is usually done from experience. For beginners, the following may be taken as a starting point:

• Fix an arbitrary (and reasonably small) size for columns. • From the axial force, find area required for each column based on short column

design formula, for 2% reinforcement.• Increase this area requirement by 25% for all internal columns and by 50% for

all periphery columns. For the decided width, find depth for the area required.• Based on above, choose depth such as 35, 40, 45, 50, 60, 70, 75, 80 cm or

more.– The dimension may be suitably re-sized later based on the Asc required

from analysis.

Analysis & Design of an RC Building in STAAD.Pro Presented by Rahul LeslieAnalysis & Design of an RC Building in STAAD.Pro & ETABS

Page 9: Modelling Building Frame with STAAD.Pro & ETABS - Rahul Leslie

9

Initial member size fixing (cont…)Slabs: • Depth:

– Calculated as minimum of [shorter span]/32 – but same depths in adjacent slabs can be convenient– Depths of 10, 11 and 12 cms are most common.– In case the depth required is more than 12 or 13 cm, one may spit the slab

using sub-beams, to bring the slab thickness to 12cm or within.

Presented by Rahul LeslieAnalysis & Design of an RC Building in STAAD.Pro & ETABS

Page 10: Modelling Building Frame with STAAD.Pro & ETABS - Rahul Leslie

1010

B

C

D

A

1 2 3 4 5

1st Floor plan – Centre-to-centre distances (m):

Presented by Rahul LeslieAnalysis & Design of an RC Building in STAAD.Pro & ETABS

Page 11: Modelling Building Frame with STAAD.Pro & ETABS - Rahul Leslie

1111

1st Floor Key plan – Beam Size:

B

A

C

D

1 2 3 4 5

Presented by Rahul LeslieAnalysis & Design of an RC Building in STAAD.Pro & ETABS

Page 12: Modelling Building Frame with STAAD.Pro & ETABS - Rahul Leslie

1212

1st Floor Key plan – Column Size:

1 2 3 4 5

B

A

C

D

Presented by Rahul LeslieAnalysis & Design of an RC Building in STAAD.Pro & ETABS

Page 13: Modelling Building Frame with STAAD.Pro & ETABS - Rahul Leslie

1313

1st Floor Key plan – Slab thickness:

B

A

C

D

1 2 3 4 5

Presented by Rahul LeslieAnalysis & Design of an RC Building in STAAD.Pro & ETABS

Page 14: Modelling Building Frame with STAAD.Pro & ETABS - Rahul Leslie

1414

Modeling Framed StructureFrame:

• Beams & columns are modeled using frame elements

• Each beam and each column is represented by single frame element (no subdividing by meshing is done)

• Beams and columns are of homogeneous isotropic elastic material with properties (E, μ) that of concrete – properties of reinforcement are not considered

Presented by Rahul LeslieAnalysis & Design of an RC Building in STAAD.Pro & ETABS

Page 15: Modelling Building Frame with STAAD.Pro & ETABS - Rahul Leslie

1515

Modeling Framed Structure

Frame:• Beam elements are oriented along the centre

line, and columns are modeled using frame elements

Presented by Rahul LeslieAnalysis & Design of an RC Building in STAAD.Pro & ETABS

Page 16: Modelling Building Frame with STAAD.Pro & ETABS - Rahul Leslie

1616Presented by Rahul LeslieAnalysis & Design of an RC Building in STAAD.Pro & ETABS

Page 17: Modelling Building Frame with STAAD.Pro & ETABS - Rahul Leslie

1717

Modeling Framed Structure

Frame:• Beam elements are oriented along the centre line, and

columns are modeled using frame elements

• Columns are located at the intersection of beams (not the centre line of the columns)

Presented by Rahul LeslieAnalysis & Design of an RC Building in STAAD.Pro & ETABS

Page 18: Modelling Building Frame with STAAD.Pro & ETABS - Rahul Leslie

1818

Column positions

Presented by Rahul LeslieAnalysis & Design of an RC Building in STAAD.Pro & ETABS

Page 19: Modelling Building Frame with STAAD.Pro & ETABS - Rahul Leslie

1919

Centre of columns as modeled

Actual centre of columns

Position of column centre lines

Presented by Rahul LeslieAnalysis & Design of an RC Building in STAAD.Pro & ETABS

Page 20: Modelling Building Frame with STAAD.Pro & ETABS - Rahul Leslie

2020

(Plan view from STAAD, col. Without offset)

Presented by Rahul LeslieAnalysis & Design of an RC Building in STAAD.Pro & ETABS

Page 21: Modelling Building Frame with STAAD.Pro & ETABS - Rahul Leslie

2121

Modeling Framed Structure

Frame:• Beam elements are oriented along the centre line, and

columns are modeled using frame elements

• Columns are located at the intersection of beams (not the centre line of the columns)

• Columns can later be moved to its actual centre line by ‘offsetting’ it.

Presented by Rahul LeslieAnalysis & Design of an RC Building in STAAD.Pro & ETABS

Page 22: Modelling Building Frame with STAAD.Pro & ETABS - Rahul Leslie

2222

(Plan view from STAAD, col. Without & With offset)

Presented by Rahul LeslieAnalysis & Design of an RC Building in STAAD.Pro & ETABS

Page 23: Modelling Building Frame with STAAD.Pro & ETABS - Rahul Leslie

2323

Modeling Framed StructureStairs:

Window on mid landing level beam

Window on floor level beam

Presented by Rahul LeslieAnalysis & Design of an RC Building in STAAD.Pro & ETABS

Page 24: Modelling Building Frame with STAAD.Pro & ETABS - Rahul Leslie

2424

Window on mid landing level beam

Presented by Rahul LeslieAnalysis & Design of an RC Building in STAAD.Pro & ETABS

Page 25: Modelling Building Frame with STAAD.Pro & ETABS - Rahul Leslie

2525

Window on floor level beam

Presented by Rahul LeslieAnalysis & Design of an RC Building in STAAD.Pro & ETABS

Page 26: Modelling Building Frame with STAAD.Pro & ETABS - Rahul Leslie

2626

Window on MLL beam Window on FL beam

Presented by Rahul LeslieAnalysis & Design of an RC Building in STAAD.Pro & ETABS

Page 27: Modelling Building Frame with STAAD.Pro & ETABS - Rahul Leslie

27

Page 28: Modelling Building Frame with STAAD.Pro & ETABS - Rahul Leslie

28

Modeling Framed StructureFrame:

• At the points where sub-beams (or secondary beams) connect to the main-beams (or primary beams), nodes have to be introduced in the latter by splitting them (though not in ETABS*).

• The bending degree of freedom of the sub-beams are released at either ends to prevent torsion in the main-beams. (Where sub beams run continuous over the main beams, only the extreme ends are released)

* This is because ETABS uses a duel model approach: the one we model is the ‘physical model’. On clicking the Analysis button, ETABS, in background, builds a an ‘analysis model’ (ie., it’s corresponding Finite Element model) which it uses for analysis. This model will have the primary beams split and nodes introduced to connect the secondary beams.

Page 29: Modelling Building Frame with STAAD.Pro & ETABS - Rahul Leslie

29

Column positions

Bending moment released at these points

Moment releases in sub-beams

Presented by Rahul LeslieAnalysis & Design of an RC Building in STAAD.Pro & ETABS

Page 30: Modelling Building Frame with STAAD.Pro & ETABS - Rahul Leslie

3030

Modeling Framed StructureToilets:

Presented by Rahul LeslieAnalysis & Design of an RC Building in STAAD.Pro & ETABS

Page 31: Modelling Building Frame with STAAD.Pro & ETABS - Rahul Leslie

3131

Modeling Framed StructureToilets:

• Toilet slabs are sunk from the floor level (to accommodate outlet pipes. The portion is then filled with lean or brick concrete. The depth of sinking is:

• 30 cm for European styled water closets and• 45 cm for Indian styled water closets • 20 cm for bath rooms

• The beams separating the sunken slab from floor slabs should bee deep enough to accommodate the floor slab as well as the sunken slab

Analysis & Design of an RC Building in STAAD.Pro & ETABS Presented by Rahul Leslie

Page 32: Modelling Building Frame with STAAD.Pro & ETABS - Rahul Leslie

32

STAAD.Pro & ETABSOne floor in

STAAD.Pro ETABS

Page 33: Modelling Building Frame with STAAD.Pro & ETABS - Rahul Leslie

33

Page 34: Modelling Building Frame with STAAD.Pro & ETABS - Rahul Leslie

34

One floor and columns

STAAD.Pro ETABS

Page 35: Modelling Building Frame with STAAD.Pro & ETABS - Rahul Leslie

3535

Supports:For Shallow Footings and Pile Foundations

Footing Pile

Presented by Rahul LeslieAnalysis & Design of an RC Building in STAAD.Pro & ETABS

Page 36: Modelling Building Frame with STAAD.Pro & ETABS - Rahul Leslie

3636

Supports:For Shallow Footings and Pile Foundations

Footing

Presented by Rahul LeslieAnalysis & Design of an RC Building in STAAD.Pro & ETABS

Page 37: Modelling Building Frame with STAAD.Pro & ETABS - Rahul Leslie

3737

Supports:For Shallow Footings and Pile Foundations

Pile

Presented by Rahul LeslieAnalysis & Design of an RC Building in STAAD.Pro & ETABS

Page 38: Modelling Building Frame with STAAD.Pro & ETABS - Rahul Leslie

3838

Supports:For Shallow Footings and Pile Foundations

• For shallow foundation, plinth beams will be at plinth level above ground (GL), while support point is located at founding level below GL.

• For pile foundation, the support point is located at top of pile cap, which is at a level 30 cm below GL.

• The grade beams will also be at the pile cap level (connecting support points in the model).

• Thus the GF columns will have a ht. = storey ht. + plinth ht. + depth of pile cap below GL

Presented by Rahul LeslieAnalysis & Design of an RC Building in STAAD.Pro & ETABS

Page 39: Modelling Building Frame with STAAD.Pro & ETABS - Rahul Leslie

3939

Supports:For Shallow Footings and Pile Foundations

Footing Pile

Presented by Rahul LeslieAnalysis & Design of an RC Building in STAAD.Pro & ETABS

Page 40: Modelling Building Frame with STAAD.Pro & ETABS - Rahul Leslie

40

Whole structure

STAAD.Pro ETABS

Page 41: Modelling Building Frame with STAAD.Pro & ETABS - Rahul Leslie

41

Whole structure

STAAD.Pro ETABS

Page 42: Modelling Building Frame with STAAD.Pro & ETABS - Rahul Leslie

42

Modeling Framed StructureSlabs:

• Floor slabs are not structurally modeled – the load on the slab (its self wt., finishes, live load, etc.) are applied as 2-way distribution on to its supporting beams

• In STAAD.Pro this is done by the 2-way distribution ‘Floor Load’ facility

• In ETABS, this is done by defining a floor object ‘membrane element’ in place of the slab, with loads on it. The membrane converts it to 2-way distribution.

Presented by Rahul LeslieAnalysis & Design of an RC Building in STAAD.Pro & ETABS

Page 43: Modelling Building Frame with STAAD.Pro & ETABS - Rahul Leslie

43STAAD.Pro ETABS

Loads applied on frame

Page 44: Modelling Building Frame with STAAD.Pro & ETABS - Rahul Leslie

44

Coordinate System

Global system

GX

GY

GZRotational directions (MX, MY and MZ) are defined as:

When looking through the axis to the origin, anticlockwise is +ve

Presented by Rahul LeslieAnalysis & Design of an RC Building in STAAD.Pro & ETABS

Page 45: Modelling Building Frame with STAAD.Pro & ETABS - Rahul Leslie

45

Coordinate System

Local system for beams

GX

GY

GZ

XY

Z

X

Y

Z

Rotational directions (MX, MY and MZ) are defined as:

When looking through the axis towards origin, anticlockwise is +ve.

Presented by Rahul Leslie

Rotational directions MY and MZ are about local Y and Z

Analysis & Design of an RC Building in STAAD.Pro & ETABS

Page 46: Modelling Building Frame with STAAD.Pro & ETABS - Rahul Leslie

46

Coordinate System

Local system for plates

Rotational directions MX and MY are along local X and Y

XY

Z

Direction Z is towards that side from which the nodes i, j, k, l in order appear anti-clockwise

k

j

i

l

Direction X is parallel to i-j, and directed from i end to j end.

Direction Y is perpendicular to X direction, and directed from j end to k end.

Presented by Rahul LeslieAnalysis & Design of an RC Building in STAAD.Pro & ETABS

Page 47: Modelling Building Frame with STAAD.Pro & ETABS - Rahul Leslie

47

Global & Local Coordinate Systems

Presented by Rahul LeslieAnalysis & Design of an RC Building in STAAD.Pro & ETABS

Page 48: Modelling Building Frame with STAAD.Pro & ETABS - Rahul Leslie

48

Global & Local Coordinate Systems

Presented by Rahul LeslieAnalysis & Design of an RC Building in STAAD.Pro & ETABS

Page 49: Modelling Building Frame with STAAD.Pro & ETABS - Rahul Leslie

49

Coordinate labels in STAAD.Pro & ETABS

Presented by Rahul Leslie

As shown in previous slides

STAAD.Pro ETABS

Analysis & Design of an RC Building in STAAD.Pro & ETABS

Page 50: Modelling Building Frame with STAAD.Pro & ETABS - Rahul Leslie

50

Loading

STAAD.Pro and ETABS have facilities for:-• Self-weight (Gravity load of elements)• Nodal loads (eg. Loads of Trusses)• Beam loading for Uni. Distr. loads, Uni. Vary. loads,

Concentrated loads, etc.

Presented by Rahul LeslieAnalysis & Design of an RC Building in STAAD.Pro & ETABS

Page 51: Modelling Building Frame with STAAD.Pro & ETABS - Rahul Leslie

51

Beam Loading

Along local X, Y, Z (-ve Y shown)

Along global GX, GY,G Z (-ve GY shown)

Along projected PX, PY, PZ (-ve GY shown)

Presented by Rahul LeslieAnalysis & Design of an RC Building in STAAD.Pro & ETABS

Page 52: Modelling Building Frame with STAAD.Pro & ETABS - Rahul Leslie

52

Slab load on Beams

In addition, almost all packages have facility to distribute floor loads on to the supporting beams directly (without modeling the slabs as elements)

Presented by Rahul LeslieAnalysis & Design of an RC Building in STAAD.Pro & ETABS

Page 53: Modelling Building Frame with STAAD.Pro & ETABS - Rahul Leslie

53

Modeling Framed Structure

Slabs:• RCC Shell roofs (like domes, hyperbolic

parabolas, cylindrical roofs, etc) and pitched roofs without skeletal beams are modeled using shell elements

• Flat slabs and flat plates are modeled using plate elements.

Presented by Rahul LeslieAnalysis & Design of an RC Building in STAAD.Pro & ETABS

Page 54: Modelling Building Frame with STAAD.Pro & ETABS - Rahul Leslie

54

Modeling Framed Structure

Slabs:For RCC pitched roofs with skeletal beams:• In STAAD.Pro this is done by a special Floor Load

distribution facility• In ETABS, this is done by modeled using shell

elements.

Presented by Rahul LeslieAnalysis & Design of an RC Building in STAAD.Pro & ETABS

Page 55: Modelling Building Frame with STAAD.Pro & ETABS - Rahul Leslie

5555

Modeling Framed Structure

Walls:• Masonry walls are not modeled, but its weight

applied as a UDL on its supporting beams.• No deductions are made for window or door

openings, nor additions made for lintels.

Presented by Rahul LeslieAnalysis & Design of an RC Building in STAAD.Pro & ETABS

Page 56: Modelling Building Frame with STAAD.Pro & ETABS - Rahul Leslie

56STAAD.Pro ETABS

Wall loads on beams

Page 57: Modelling Building Frame with STAAD.Pro & ETABS - Rahul Leslie

5757

Modeling Framed StructureWalls:

• Masonry walls are not modeled, but its weight applied as a UDL on its supporting beams

• No deductions are made for window or door openings, nor additions made for lintels

• Shear walls are modeled using plate elements• Surface elements in STAAD• Wall elements in ETABS

• Retaining walls cast monolith with the structure may be modeled using plate elements

Presented by Rahul LeslieAnalysis & Design of an RC Building in STAAD.Pro & ETABS

Page 58: Modelling Building Frame with STAAD.Pro & ETABS - Rahul Leslie

58

Modeling Framed Structure

Stairs:• Stairs are usually not modeled, instead their

load applied as a UDL on its supporting beams

Presented by Rahul LeslieAnalysis & Design of an RC Building in STAAD.Pro & ETABS

Page 59: Modelling Building Frame with STAAD.Pro & ETABS - Rahul Leslie

59STAAD.Pro ETABS

Stair load applied on model

Page 60: Modelling Building Frame with STAAD.Pro & ETABS - Rahul Leslie

6060

Modeling Framed Structure

Foundation:• Pile and Raft foundations are modeled as fixed

support. • Isolated footings are modeled as fixed or

pinned, depending on the SBC & Nature of soil at founding depth

Presented by Rahul LeslieAnalysis & Design of an RC Building in STAAD.Pro & ETABS

Page 61: Modelling Building Frame with STAAD.Pro & ETABS - Rahul Leslie

61

Concrete• fck = 20 N/mm2

• E = 5000 √(fck) = 22360.68 N/mm2

• Poisson’s ratio = 0.2• Density = 25 kN/m3

Material Properties

Presented by Rahul LeslieAnalysis & Design of an RC Building in STAAD.Pro & ETABS

Page 62: Modelling Building Frame with STAAD.Pro & ETABS - Rahul Leslie

62

LoadsDead Load (IS:875 part 1):

• Slabs (10 cm) : • STAAD: 0.1x25+1.25 = 3.75 kN/m2 (SelfWt: 0.1x25=2.5 kN/m2)• ETABS : 1.25 kN/m2

• Toilet slabs : • Indian closet: 0.45x20 = 9 kN/m2 , + SelfWt (for STAAD)• Euro. closet: 0.3x20 = 6 kN/m2, + SelfWt (for STAAD)

• Roof slabs : 2.0 kN/m2, + SelfWt (for STAAD)• Walls (23 cm brick, with 40 cm beam overhead) :

(3.6 - 0.4)x0.23x20 = 14.72 kN/m• Sun shade projection (60 cm wide, 7.5 cm average

thickness): 0.6x0.075x25 = 1.13 kN/m

Presented by Rahul LeslieAnalysis & Design of an RC Building in STAAD.Pro & ETABS

Page 63: Modelling Building Frame with STAAD.Pro & ETABS - Rahul Leslie

63

LoadsDead Load:

• Stairs

Presented by Rahul LeslieAnalysis & Design of an RC Building in STAAD.Pro & ETABS

Page 64: Modelling Building Frame with STAAD.Pro & ETABS - Rahul Leslie

64

LoadsDead Load (IS:875 part 1):

• Stairs • Slab wt (concrete) :

• Steps (brick work):

• Finish:

• Total = 5.59 + 1.5 + 0.75 = 7.84 kN/m2

222

5.59kN/m253.0

3.015.02.0

2kN/m5.120215.0

2kN/m75.05.03.0

15.03.0

Presented by Rahul LeslieAnalysis & Design of an RC Building in STAAD.Pro & ETABS

Page 65: Modelling Building Frame with STAAD.Pro & ETABS - Rahul Leslie

65

Loads

Dead Load (IS:875 part 1):• Stairs

• Total = 5.59 + 1.5 + 0.75 = 7.84 kN/m2

• Load on beams (4.57 m span) = 4.57x7.84/2 = 17.92 kN/m

Presented by Rahul LeslieAnalysis & Design of an RC Building in STAAD.Pro & ETABS

Page 66: Modelling Building Frame with STAAD.Pro & ETABS - Rahul Leslie

66

Loads

Live Load (IS:875 part 2):BUSINESS AND OFFICE BUILDINGS:-

• Office/Conference: 2.5 kN/m2 • Stores: 5 kN/m2 • Dinning: 3 kN/m2 • Toilet: 2 kN/m2

• Corridors/Stairs: 4 kN/m2

• Roof: 1.5 kN/m2

Presented by Rahul LeslieAnalysis & Design of an RC Building in STAAD.Pro & ETABS

Page 67: Modelling Building Frame with STAAD.Pro & ETABS - Rahul Leslie

6767

Loads

Live Load (IS:875 part 2):• Stairs

• Live Load = 4 kN/m2

• Load on beams (4.57 m span) = 4x8.59/2 = 17.18

kN/m

Presented by Rahul LeslieAnalysis & Design of an RC Building in STAAD.Pro & ETABS

Page 68: Modelling Building Frame with STAAD.Pro & ETABS - Rahul Leslie

68

Loads

Live Load (IS:875 part 2):• Water tank on slab (5000 lts):

5000 lts = 5 m3 = 50 kNLoad = 50/(3.45x1.93) = 7.51

kN/m2

Presented by Rahul LeslieAnalysis & Design of an RC Building in STAAD.Pro & ETABS

Page 69: Modelling Building Frame with STAAD.Pro & ETABS - Rahul Leslie

69

Loads

Load Combination for Design

• 1.5 x Dead Load + 1.5 x Live Load

Load Combination for Foundation

• 1.0 x Dead Load + 1.0 x Live Load

Presented by Rahul LeslieAnalysis & Design of an RC Building in STAAD.Pro & ETABS

Page 70: Modelling Building Frame with STAAD.Pro & ETABS - Rahul Leslie

70STAAD.Pro ETABS

Run Analysis

Page 71: Modelling Building Frame with STAAD.Pro & ETABS - Rahul Leslie

71STAAD.Pro ETABS

Bending Moment

Page 72: Modelling Building Frame with STAAD.Pro & ETABS - Rahul Leslie

72STAAD.Pro ETABS

Shear Force

Page 73: Modelling Building Frame with STAAD.Pro & ETABS - Rahul Leslie

73STAAD.Pro ETABS

BM & SF of 2nd Floor

Page 74: Modelling Building Frame with STAAD.Pro & ETABS - Rahul Leslie

74

RCC Design

Parameters specified

• Load case used =1.5 Dead Load + 1.5 Live Load

• Code = IS 456 : 2000• fck = 20 N/mm2

• fy(main) = 415 N/mm2

• fy(shear) = 415 N/mm2

Presented by Rahul LeslieAnalysis & Design of an RC Building in STAAD.Pro & ETABS

Page 75: Modelling Building Frame with STAAD.Pro & ETABS - Rahul Leslie

75

Model with initial cross sectional dimensions

Run Analysis and design

Check design results

Are design results okay?

Finish

Modify cross sectional dimensions/Layout

Yes

No

Design cycle for RC Structures

Presented by Rahul LeslieAnalysis & Design of an RC Building in STAAD.Pro & ETABS

Page 76: Modelling Building Frame with STAAD.Pro & ETABS - Rahul Leslie

76STAAD.Pro ETABS

Beam Design Output

Main rein.Shear rein.

Page 77: Modelling Building Frame with STAAD.Pro & ETABS - Rahul Leslie

77

============================================================================ B E A M N O. 141 D E S I G N R E S U L T S M20 Fe415 (Main) Fe415 (Sec.) LENGTH: 4570.0 mm SIZE: 230.0 mm X 400.0 mm COVER: 25.0 mm SUMMARY OF REINF. AREA (Sq.mm) ---------------------------------------------------------------------------- SECTION 0.0 mm 1142.5 mm 2285.0 mm 3427.5 mm 4570.0 mm ---------------------------------------------------------------------------- TOP 584.24 0.00 0.00 0.00 645.83 REINF. (Sq. mm) (Sq. mm) (Sq. mm) (Sq. mm) (Sq. mm) BOTTOM 0.00 173.83 429.94 173.83 0.00 REINF. (Sq. mm) (Sq. mm) (Sq. mm) (Sq. mm) (Sq. mm) ----------------------------------------------------------------------------

============================================================================ B E A M N O. 142 D E S I G N R E S U L T S

M20 Fe415 (Main) Fe415 (Sec.) LENGTH: 1930.0 mm SIZE: 230.0 mm X 400.0 mm COVER: 25.0 mm

SUMMARY OF REINF. AREA (Sq.mm)

---------------------------------------------------------------------------- SECTION 0.0 mm 482.5 mm 965.0 mm 1447.5 mm 1930.0 mm ---------------------------------------------------------------------------- TOP 188.88 173.83 173.83 173.83 173.83 REINF. (Sq. mm) (Sq. mm) (Sq. mm) (Sq. mm) (Sq. mm)

BOTTOM 0.00 0.00 0.00 0.00 0.00 REINF. (Sq. mm) (Sq. mm) (Sq. mm) (Sq. mm) (Sq. mm) ----------------------------------------------------------------------------

Beam Design Output of STAAD.Pro

Presented by Rahul LeslieAnalysis & Design of an RC Building in STAAD.Pro & ETABS

Page 78: Modelling Building Frame with STAAD.Pro & ETABS - Rahul Leslie

7878Presented by Rahul Leslie

============================================================================ B E A M N O. 141 D E S I G N R E S U L T S M20 Fe415 (Main) Fe415 (Sec.) LENGTH: 4570.0 mm SIZE: 230.0 mm X 400.0 mm COVER: 25.0 mm SUMMARY OF REINF. AREA (Sq.mm) ---------------------------------------------------------------------------- SECTION 0.0 mm 1142.5 mm 2285.0 mm 3427.5 mm 4570.0 mm ---------------------------------------------------------------------------- TOP 584.24 0.00 0.00 0.00 645.83 REINF. (Sq. mm) (Sq. mm) (Sq. mm) (Sq. mm) (Sq. mm) BOTTOM 0.00 173.83 429.94 173.83 0.00 REINF. (Sq. mm) (Sq. mm) (Sq. mm) (Sq. mm) (Sq. mm) ----------------------------------------------------------------------------

Analysis & Design of an RC Building in STAAD.Pro & ETABS

Page 79: Modelling Building Frame with STAAD.Pro & ETABS - Rahul Leslie

79

============================================================================ B E A M N O. 141 D E S I G N R E S U L T S M20 Fe415 (Main) Fe415 (Sec.) LENGTH: 4570.0 mm SIZE: 230.0 mm X 400.0 mm COVER: 25.0 mm SUMMARY OF REINF. AREA (Sq.mm) ---------------------------------------------------------------------------- SECTION 0.0 mm 1142.5 mm 2285.0 mm 3427.5 mm 4570.0 mm ---------------------------------------------------------------------------- TOP 584.24 0.00 0.00 0.00 645.83

REINF. (Sq. mm) (Sq. mm) (Sq. mm) (Sq. mm) (Sq. mm) BOTTOM 0.00 173.83 429.94 173.83 0.00 REINF. (Sq. mm) (Sq. mm) (Sq. mm) (Sq. mm) (Sq. mm) ---------------------------------------------------------------------------- SUMMARY OF PROVIDED REINF. AREA ---------------------------------------------------------------------------- SECTION 0.0 mm 1142.5 mm 2285.0 mm 3427.5 mm 4570.0 mm ---------------------------------------------------------------------------- TOP 6-12í 2-12í 2-12í 2-12í 6-12í REINF. 2 layer(s) 1 layer(s) 1 layer(s) 1 layer(s) 2 layer(s) BOTTOM 2-12í 2-12í 4-12í 2-12í 2-12í REINF. 1 layer(s) 1 layer(s) 1 layer(s) 1 layer(s) 1 layer(s) SHEAR 2 legged 8í 2 legged 8í 2 legged 8í 2 legged 8í 2 legged 8í REINF. @ 120 mm c/c @ 120 mm c/c @ 120 mm c/c @ 120 mm c/c @ 120 mm c/c ---------------------------------------------------------------------------- SHEAR DESIGN RESULTS AT DISTANCE d (EFFECTIVE DEPTH) FROM FACE OF THE SUPPORT SHEAR DESIGN RESULTS AT 540.0 mm AWAY FROM START SUPPORT VY = 74.90 MX = -0.90 LD= 3 Provide 2 Legged 8í @ 120 mm c/c SHEAR DESIGN RESULTS AT 540.0 mm AWAY FROM END SUPPORT VY = -79.08 MX = -0.90 LD= 3 Provide 2 Legged 8í @ 120 mm c/c ============================================================================

Page 80: Modelling Building Frame with STAAD.Pro & ETABS - Rahul Leslie

80

============================================================================ B E A M N O. 141 D E S I G N R E S U L T S M20 Fe415 (Main) Fe415 (Sec.) LENGTH: 4570.0 mm SIZE: 230.0 mm X 400.0 mm COVER: 25.0 mm SUMMARY OF REINF. AREA (Sq.mm) ---------------------------------------------------------------------------- SECTION 0.0 mm 1142.5 mm 2285.0 mm 3427.5 mm 4570.0 mm ---------------------------------------------------------------------------- TOP 584.24 0.00 0.00 0.00 645.83 REINF. (Sq. mm) (Sq. mm) (Sq. mm) (Sq. mm) (Sq. mm) BOTTOM 0.00 173.83 429.94 173.83 0.00 REINF. (Sq. mm) (Sq. mm) (Sq. mm) (Sq. mm) (Sq. mm) ----------------------------------------------------------------------------

Continued...

Presented by Rahul LeslieAnalysis & Design of an RC Building in STAAD.Pro & ETABS

Page 81: Modelling Building Frame with STAAD.Pro & ETABS - Rahul Leslie

81

...Continued

SUMMARY OF PROVIDED REINF. AREA ---------------------------------------------------------------------------- SECTION 0.0 mm 1142.5 mm 2285.0 mm 3427.5 mm 4570.0 mm ---------------------------------------------------------------------------- TOP 6-12í 2-12í 2-12í 2-12í 6-12í REINF. 2 layer(s) 1 layer(s) 1 layer(s) 1 layer(s) 2 layer(s) BOTTOM 2-12í 2-12í 4-12í 2-12í 2-12í REINF. 1 layer(s) 1 layer(s) 1 layer(s) 1 layer(s) 1 layer(s) SHEAR 2 legged 8í 2 legged 8í 2 legged 8í 2 legged 8í 2 legged 8í REINF. @ 120 mm c/c @ 120 mm c/c @ 120 mm c/c @ 120 mm c/c @ 120 mm c/c ---------------------------------------------------------------------------- SHEAR DESIGN RESULTS AT DISTANCE d (EFFECTIVE DEPTH) FROM FACE OF THE SUPPORT SHEAR DESIGN RESULTS AT 540.0 mm AWAY FROM START SUPPORT VY = 74.90 MX = -0.90 LD= 3 Provide 2 Legged 8í @ 120 mm c/c SHEAR DESIGN RESULTS AT 540.0 mm AWAY FROM END SUPPORT VY = -79.08 MX = -0.90 LD= 3 Provide 2 Legged 8í @ 120 mm c/c ============================================================================

Presented by Rahul LeslieAnalysis & Design of an RC Building in STAAD.Pro & ETABS

Page 82: Modelling Building Frame with STAAD.Pro & ETABS - Rahul Leslie

82Presented by Rahul LeslieAnalysis & Design of an RC Building in STAAD.Pro & ETABS

Page 83: Modelling Building Frame with STAAD.Pro & ETABS - Rahul Leslie

83

Asv/Sv = 0.356Asv = 2Leg, #8 = 100.53.:Sv = 100.53 / 0.356 = 282 mm c/c

Provide 2L#8@180 mm c/c

Page 84: Modelling Building Frame with STAAD.Pro & ETABS - Rahul Leslie

84Presented by Rahul LeslieAnalysis & Design of an RC Building in STAAD.Pro & ETABS

Page 85: Modelling Building Frame with STAAD.Pro & ETABS - Rahul Leslie

85

Detailing as per SP 34(Sample beam)

Presented by Rahul LeslieAnalysis & Design of an RC Building in STAAD.Pro & ETABS

Page 86: Modelling Building Frame with STAAD.Pro & ETABS - Rahul Leslie

86Presented by Rahul LeslieAnalysis & Design of an RC Building in STAAD.Pro & ETABS

Page 87: Modelling Building Frame with STAAD.Pro & ETABS - Rahul Leslie

87

Column reinforcement (mm2):

Presented by Rahul LeslieAnalysis & Design of an RC Building in STAAD.Pro & ETABS

Page 88: Modelling Building Frame with STAAD.Pro & ETABS - Rahul Leslie

88

Column Groups:

Presented by Rahul LeslieAnalysis & Design of an RC Building in STAAD.Pro & ETABS

Page 89: Modelling Building Frame with STAAD.Pro & ETABS - Rahul Leslie

89

Column Schedule:

Presented by Rahul LeslieAnalysis & Design of an RC Building in STAAD.Pro & ETABS

Page 90: Modelling Building Frame with STAAD.Pro & ETABS - Rahul Leslie

90STAAD.Pro ETABS

Support Reactions

Page 91: Modelling Building Frame with STAAD.Pro & ETABS - Rahul Leslie

91Presented by Rahul LeslieAnalysis & Design of an RC Building in STAAD.Pro & ETABS

Page 92: Modelling Building Frame with STAAD.Pro & ETABS - Rahul Leslie

92

SBC = 160 kN/m2

Presented by Rahul LeslieAnalysis & Design of an RC Building in STAAD.Pro & ETABS

Page 93: Modelling Building Frame with STAAD.Pro & ETABS - Rahul Leslie

9393

Footing Design

• Further adjust size of footing considering support moments

ZzMz

ZxMx

APp

1.1

SBCp

Presented by Rahul LeslieAnalysis & Design of an RC Building in STAAD.Pro & ETABS

Page 94: Modelling Building Frame with STAAD.Pro & ETABS - Rahul Leslie

94

Provide combined footing for these columns

Presented by Rahul LeslieAnalysis & Design of an RC Building in STAAD.Pro & ETABS

Page 95: Modelling Building Frame with STAAD.Pro & ETABS - Rahul Leslie

95Presented by Rahul LeslieAnalysis & Design of an RC Building in STAAD.Pro & ETABS

Page 96: Modelling Building Frame with STAAD.Pro & ETABS - Rahul Leslie

9696Presented by Rahul LeslieAnalysis & Design of an RC Building in STAAD.Pro & ETABS

Page 97: Modelling Building Frame with STAAD.Pro & ETABS - Rahul Leslie

9797

Pile Capacity = 750 kN

Presented by Rahul LeslieAnalysis & Design of an RC Building in STAAD.Pro & ETABS

Page 98: Modelling Building Frame with STAAD.Pro & ETABS - Rahul Leslie

9898

Pile Design

• Further check no. of piles, considering support moments

IzdxMz

IxdzMx

nPp ii

i

2.1

2dzIx

2dxIz

.PileCappi

Presented by Rahul LeslieAnalysis & Design of an RC Building in STAAD.Pro & ETABS

Page 99: Modelling Building Frame with STAAD.Pro & ETABS - Rahul Leslie

9999Presented by Rahul LeslieAnalysis & Design of an RC Building in STAAD.Pro & ETABS

Page 100: Modelling Building Frame with STAAD.Pro & ETABS - Rahul Leslie

100100

Concluding remarks

Page 101: Modelling Building Frame with STAAD.Pro & ETABS - Rahul Leslie

101101

Concluding remarks• To use a software package, one has to know it

• More importantly, one has to know its limitations,

• Still more important, one has to know its pitfalls.

• Software Demonstrators/Instructors may tell you the limitations, but not the pitfalls. Mostly it can be learned only through experience.

• They are also fond of promoting the idea that “The software does everything; You don’t have to know anything!”. Please don’t take the software for granted.

Presented by Rahul LeslieAnalysis & Design of an RC Building in STAAD.Pro & ETABS

Page 102: Modelling Building Frame with STAAD.Pro & ETABS - Rahul Leslie

102102

Concluding remarks• A basic understanding of FEM is desirable (but not

necessary), especially when flat-slabs, shear walls or shell roofs are included.

• Also one has to know the code provisions, and have them ready reference (IS:456, SP-34, IS:875 Part-I & II, IS:1904, IS:2911)

• For seismic design, refer to IS:1893 & IS:13920 and to include wind forces, refer to IS:875 Part-III.

Presented by Rahul LeslieAnalysis & Design of an RC Building in STAAD.Pro & ETABS