Upload
massimo-capriolo
View
110
Download
2
Embed Size (px)
Citation preview
per
1/20
Il processo di Il processo di accreditamento Nadcap accreditamento Nadcap
visto dal suppliervisto dal supplier
M. Capriolo / M. F. Bianchi
BYTEST
per
2/20
:22 Aziende accreditate
NDT in Italia
Alenia Aermacchi
Alenia Aeronavali
NU
Alenia Aeronautica
Avio Rivalta
Avio PomiglianoAvio Acerra
ILMAS
Metalsud
Microfusione Stellite
Moreggia
Officine Meccaniche Aeronautiche
OMPM
Piaggio Aero Industries
Pietro Rosa T.B.M.
Processi SpecialiSalver
Secondo Mona
Sicamb
SKF IndustriesTeksid Aluminum
Umbra Cuscinetti
Wind
NU
LEGENDA
Accreditato NUCAP
Accreditato PT
Accreditato MT
Accreditato UT
Accreditato RT
Europea Microfusioni Aerospaziali
BYTEST
Dati disponibili – Maggio 2007
per
3/20
: 36 Aziende accreditate in Italia
NUC
AP
AQS
COM
P
CP
CT
ETG
HT
MTL
NDT
NM
SE
WLD
Accr
edita
men
to
NUC
AP
Aero
spac
e Q
ualità
Sy
stem
Com
posit
es
Che
mic
al Pr
oces
sing
Coa
ting
Elec
tronic
s
Hea
t Tre
atin
g
Mat
eria
ls Te
stin
g
Non
Des
truct
ive
Test
ing
Non
conv
entio
nal
Mac
hini
ng
Surfa
ce E
nhan
cem
ent
Wel
ding
Alenia Aermacchi Venegono Superiore (VA) Alenia Aeronautica Pomigliano d’Arco (NA) Alenia Aeronavali Tessera (VE) Av io Acerra (NA) Av io Pomigliano d’Arco (NA) Av io Riv alta (TO) By test Volpiano (TO) C.A.M. Paolisi (BN) C.A.M.E.P. Cardito (NA) Costruzioni Aeronautiche Bertola Marcon (VE) DEMA Somma Vesuviana (NA) Europea Microfusioni Aerospaziali Morra De Sanctis (AV) Forgital Italy Seghe Di Vilo (VI) Ground Support Equipment Brindisi ILMAS Cascine Vica Rivoli (TO) Metal Sud Arienzo (CE) Microfusione Stellite Fizzonasco di Pieve Em. (MI) Moreggia Collegno (TO) O.V.S. Villella Sesto Calende (VA) Officine Meccaniche Aeronautiche Foligno (PG) OMA SUD Capua (CE) OMPM Angri (SA) Piaggio Aero Industries Finale Ligure (SV) Pietro Rosa TBM Maniago (PN) Processi Speciali Brindisi RTM BREDA Carrè (VI) Salv er Brindisi Secondo Mona Somma Lombardo (VA) Sicamb Latina SKF Industries Villar Perosa (TO) Somacis Castelfidardo (AN) Somacis Manfredonia (FG) Teksid Aluminum Getti Speciali Borgaretto (TO) Tesi Tecnologie Servizi Innovati Cercola (NA) Umbra Cuscinetti Foligno (PG) Wind Marcianise (CE)
Totali 1 3 4 17 3 2 17 2 22 4 7 11
Ripartizione per Processi Speciali
0,1
1
10
100
AQ
S
CP CT
CO
MP
DIS
ELA
S
ET
G
FA
ST
FLU H
T
MT
L
NU
CA
P
ND
T
NM
SLT SE
WLD
RTM BREDA S.r.l.Via Bianche 18 Carrè (Vicenza), ITALY 36010ItalyPhone: 0445-315-462Fax: 0445-315-466
Bytest SRLVia Pisa 12Volpiano (TO), ITALY 10088ItalyPhone: 011-995-3845Fax: 011-995-3853
BYTEST
Dati disponibili – Maggio 2007
per
4/20
: 536 Aziende accreditate in Europa & C*
Ripartizione in Europa & C*
0,1
1
10
100
1000
Reg
no U
nito
Fra
ncia
Spa
gna
Ital
ia
Ger
man
ia
Isra
ele
Ola
nda
Svi
zzer
a
Bel
gio
Pol
onia
Tur
chia
Aus
tria
Rom
ania
Cec
hia
Sve
zia
Rus
sia
Sud
afric
a
Indi
a
Fin
land
ia
Gre
cia
Ung
heria
Irla
nda
Liec
hten
stei
n
Luss
embu
rgo
Tun
isia
Pak
ista
n
Azi
en
de
53%
11%
8%
7%
4%
3%
3%2%2%1%1%1%1%1%1%0%0%0%0%0%0%0%0%
* NotaSono considerati nel Gruppo europeo:• Israele• Tunisia• Sudafrica• India• Pakistan
Dati disponibili – Maggio 2007
per
5/20
: 2157 Aziende accreditate nel Mondo
Ripartizione per Processi Speciali
0,1
1
10
100
1000
AQ
S
CP CT
CO
MP
DIS
ELA
S
ET
G
FA
ST
FLU H
T
MT
L
NU
CA
P
ND
T
NM
SLT SE
WLD
Processi Speciali
Azi
en
de
Europa
America
Asia
Ripartizione per Aziende
Europa25%
Asia7%
America68%
1461
545151
Dati disponibili – Maggio 2007
per
6/20
www.bytest.com
Un’azienda di servizio per gli NDT e le Prove sui Materiali, in sintesi: 2500 metri quadri di laboratori nella propria sede
5300 keuro di fatturato nel 2006
N° 80 persone attualmente impiegate tra cui:
N° 6 Livelli 3 NDT (n° 3 secondo NAS 410/EN4179)
N° 41 Livelli 2 NDT (n° 9 secondo NAS 410/EN4179)
Fondata nel 1986
N° 4 tecnici con esperienza pluridecennale nel settore aeronautico
per
9/20Le certificazioni a Settembre 2007Le certificazioni a Settembre 2007
RT PLT
PLTFA
PT
MT
UT
ALTR
I NDT
CA
NTIER
I
FORMAZIONE
Alenia Spazio
SinalISO9001/EN9100
AermacchiAgusta
I.I.S.CICPND
Nadcap
ITANDTB
AvioGEAE
ENAC
per
10/20
Accreditamento Nadcap: Perché ?
Perché ormai l'accreditamento Nadcap è un pre-requisito di molte commesse nel settore aeronautico imposto sui Processi Speciali a livello contrattuale.
Perché alcuni Clienti della Bytest l’hanno richiesto espressamente come flown-down di requisiti contrattuali con i loro Clienti (Primes).
Perché far parte di una lista di oltre 2000 Aziende accreditate dal Nadcap che tendono all’eccellenza nel loro settore specifico è un riconoscimento a livello mondiale.
Perché gli audit di accreditamento Nadcap sono un’ottimo metodo di autovalutazione della propria attività per il mantenimento dei criteri di efficienza del processo.
per
11/20
Per prepararsi all’audit Nadcap
Scaricate dal sito Nadcap (Audinet) la o le check-list relative ai processi speciali da auditare.
Rispontere alle check-list in modo oggettivo e documentabile con evidenze oggettive, tenendo conto degli handbook dei requisiti disponibili su Audinet.
Iniziate a prepararvi almeno 90 giorni prima in modo da introdurre le azioni correttive prima dell’audit o, al limite, da iniziare a pianificarle/predisporle appena dopo l’audit.
Preparate il personale identificando responsabilità e modi per reperire rapidamente la documentazione appropriata.
Assicuratevi di avere a disposizione particolari aeronautici per la data dell’audit.
Dove richiesto (es.NDT) identificate i Clienti poiché le check-list cambiano a seconda del Prime.
Consultate il sito Nadcap dove è disponibile tutta una serie di “tutorial” anche con sessioni di training via web (www.pri-network.org/Nadcap/Audit-Preparation).
per
12/20
Appena sostenuto l’audit Nadcap
Dopo qualche giorno dalla fine dell’audit vedrete comparire le risultanze in internet su audinet (accesso con password).
Per la prima tornata di risposte a tutte le NCR si hanno 3 settimane (da evitare risposte parziali perché contano comunque come una tornata).
Per le successive tornate di risposte si ha una settimana.
Oltre alle tempistiche di cui sopra è ammesso un ritardo complessivo di 45 giorni per ogni ciclo di certificazione.
Il superamento dei 3 cicli di risposta (o come disposto dal Task Group specifico, es. NDT 4) diventa oggetto di attenzione e può determinare il fallimento dell’audit.
Motivi di fallimento dell’ audit : interruzione Audit, troppi findings, rilevanza dei findings, troppi cicli di risposta o mancata risposta.
per
13/20
Gestione del processo speciale NDT e accreditamento
Expires: 01-31-2008 I ssued: 01-08-2007
AC7114 - Nadcap NonDes tructive (NDT ) Suppliers Accreditation P rogram Audit C riteria (T o be used BEFORE 04- DEC-2006)
AC7114/4 - Nadcap Audit C riteria for NonDestructive T es ting Facility Radiography Survey (T o be used BEFORE 04-DEC-2006)
» S-U0 Unknown
» S-U00 None
» S-U1 Honeywell
» S-U10 GE
» S-U11 The Boeing Company
» S-U2 Pratt & Whitney
» S-U3 Rolls-Royce PLC
» S-U4 Lockheed Martin
» S-U5 Eurocopter
» S-U6 Rolls-Royce Corporation
» S-U7 MTU
» S-U8 Airbus
» S-U9 Raytheon
Nota - I criteri per l’audit Bytest sono anteriori al 4-dic-2006. Dopo tale data per gli NDT entra in vigore il sistema baseline/supplemental requirements a seconda dei seguenti Primes:
Scopes /Accreditation Methods for NonDestructive Testing
AC7006 REV E - Audit Criteria For Accreditation To ISO/IEC 17025 - Download checklist from Materials Testing
AC7108/2 - Nadcap Audit Criteria for Etching Process (Pre-Penetrant, Nital, Temper) - Download checklist from Chem Processing
AC7114 - Nadcap NonDestructive (NDT) Suppliers Accreditation Program Audit Criteria (To be used BEFORE 04-DEC-2006)
AC7114 Rev A - Nadcap NonDestructive Testing (NDT) Suppliers Accreditation Program Audit Criteria (To be used ON or AFTER 04-DEC-2006)
AC7114 S - Supplemental Audit Criteria for Nadcap NonDestructive (NDT) Suppliers Accreditation Program Audit Criteria (To be used ON or AFTER 04-DEC-2006)
AC7114/1 - Nadcap Audit Criteria for NonDestructive Testing Facility Penetrant Survey (To be used BEFORE 04-DEC-2006)
AC7114/1 Rev A - Nadcap Audit Criteria for NonDestructive Testing Facility Penetrant Survey (To be used ON or AFTER 04-DEC-2006)
AC7114/1S - Supplemental Audit Criteria for Nadcap Audit Criteria for NonDestructive Testing Facility Penetrant Survey (To be used ON or AFTER 04-DEC-2006)
AC7114/2 - Nadcap Audit Criteria for NonDestructive Testing Magnetic Particle Survey (To be used BEFORE 04-DEC-2006)
AC7114/2 Rev A - Nadcap Audit Criteria for NonDestructive Testing Magnetic Particle Survey (T o be used ON or AFTER 04-DEC-2006)
AC7114/2S - Supplemental Audit Criteria for Nadcap Audit Criteria for NonDestructive Testing Magnetic Particle Survey (To be used ON or AFTER 04-DEC-2006)
AC7114/3 - (audits conducted before 07/07/03) Nadcap Audit Criteria for Nondestructive Testing Facility Ultrasonic Survey
AC7114/3 Rev A - Nadcap Audit Criteria for NonDestructive Testing Facility Ultrasonic Survey (To be used BEFORE 04-DEC-2006)
AC7114/3 Rev B - Nadcap Audit Criteria for NonDestructive Testing Facility Ultrasonic Survey (To be used ON or AFTER 04-DEC-2006)
AC7114/3S - Supplemental Audit Criteria for Nadcap Audit Criteria for NonDestructive Testing Facility Ultrasonic Survey (To be used ON or AFTER 04-DEC-2006)
AC7114/4 - Nadcap Audit Criteria for NonDestructive Testing Facility Radiography Survey (T o be used BEFORE 04-DEC-2006)
AC7114/4 Rev A - Nadcap Audit Criteria for NonDestructive Testing Facility Radiography Survey (To be used ON or AFTER 04-DEC-2006)
AC7114/4S - Supplemental Audit Criteria for Nadcap Audit Criteria for NonDestructive Testing Facility Radiography Survey (To be used ON or AFTER 04-DEC-2006)
per
14/20
Iter di accreditamento NDT: RT
data 29-30/11/06 B:22/12/06
N:22/12/06
B:29/12/06
N:30/12/06
B:30/12/06
N:2/1/07
8/1/06 5-8/11/07
Audit
NCR1 (Major) Open Open
NCR2 (Major) Open
Accreditamento
Prossimo audit
B = risposta di Bytest
N = replica del Nadcap
Supplier days: 26
Cycle Count: 3(generalmente 4 sono considerati eccessivi per NDT)
per Una NCR emblematica:mancato flow-downOrdine del
Prime Pal Sub-contractor
Ordine del
Sub-contractor Sa Fonderia
Ordine della
Fonderia Falla Bytest
Norme
P
Norme
S
Norme
F
Bytest operasecondo contrattocon la Fonderia
Norme
F
SI
Norme
P?
Conformità a
Audit
?Conformità a
Audit
Norme
F Accettazione conriserva di riesameStaff Enginnering
Accreditamento
SI
NCR
NO
Prime P confermapiena applicabilità
sue norme
NCRFonderia F dota
Bytest di Norme
P
Altre azioni Bytestes. analisi impatto
sul prodotto
Riesame favorevoledello
Staff Engineering
S promette initialaudit (Aprile 2007)
NO
Staff Engineeringcontatta Prime P
15/20
per
16/20
Gestione del processo speciale MTL e accreditamento
Expires: 10-31-2008 Supplier has received merit for this accreditation I ssued: 03-29-2007
AC7101/1Rev C- Nadcap Audit C riteria for Materials T esting Laboratories - General Requirements for All Laboratories (to be used for audits conducted on or after February 27 , 2006)
AC7101/3 Rev B - Nadcap A udit C riteria for Materials T est Laboratories - Mechanical T esting (T o be used on audits conducted ON or AFTER 25-DEC-2006) (A )Room T emperature Tens ile (B)Elevated T emperature T ensile (C )Stress Rupture (N )I mpact
AC7101/5 Rev B - Nadcap A udit C riteria for Materials T esting Laboratories - Hardness (to be used for audits conducted on or after February 27 , 2006) (M1)Brinell Hardness (M2)Rockwell Hardness (M3)Vickers Hardness
AC7101/7 Rev B - Nadcap A udit C riteria for Materials T esting Laboratories - Mechanical Tes ting Specimen P reparation (to be used on audits conducted on or after February 27 , 2006) (Z)S tandard Specimen Machining
I SO/IEC 17025 - C urrently accredited by an I LAC approved source
Lab Type I ndependent
AC7005- Fastener Quality Act
AC7006 - Nadcap Audit Criteria for Accreditation to I SO/ I EC Guide 25
AC7006 RevC - Nadcap Audit Criteria for Accreditation to I SO/ I EC 17025 Calibration & Other
AC7006 RevC - Nadcap Audit Criteria for Accreditation to I SO/ I EC 17025 Testing
AC7006 RevD - Audit Criteria for Accreditation to I SO/ I EC 17025
AC7006 RevE - Audit Criteria for Accreditation to I SO/ I EC 17025 (to be used on audits conducted BEFORE 25-J une- 2007)
AC7101/11 Rev A - Nadcap Audit Criteria for Materials Test Laboratories - Fastener Testing
AC7101/1Rev A - Nadcap Audit Criteria for Materials Testing Laboratories - General Requirements for All Laboratories
AC7101/1Rev B - Nadcap Audit Criteria for Materials Testing Laboratories - General Requirements for All Laboratories (to be used for audits conducted before February 27, 2006)
AC7101/1Rev C- Nadcap Audit Criteria for Materials Testing Laboratories - General Requirements for All Laboratories (to be used for audits conducted on or after February 27, 2006)
AC7101/2 Rev A - Nadcap Audit Criteria for Materials Test Laboratories - Chemical Testing (to be used for audits conducted before February 27, 2006)
AC7101/2 Rev B - Nadcap Audit Criteria for Materials Test Laboratories - Chemical Testing (to be used for audits conducted on or after February 27, 2006)
AC7101/3 Rev A - Nadcap Audit Criteria for Materials Test Laboratories - Mechanical Testing (To be used on audits conducted BEFORE 25-DEC-2006)
AC7101/3 Rev B - Nadcap Audit Criteria for Materials Test Laboratories - Mechanical Testing (To be used on audits conducted ON or AFTER 25-DEC-2006)
AC7101/4 Rev B - Nadcap Audit Criteria for Materials Testing Laboratories - Metallography and Microhardness (to be used for audits conducted before February 27, 2006)
AC7101/4 Rev C - Nadcap Audit Criteria for Materials Testing Laboratories - Metallography and Microhardness
AC7101/5 Rev A - Nadcap Audit Criteria for Materials Testing Laboratories - Hardness (to be used for audits conducted before February 27, 2006)
AC7101/5 Rev B - Nadcap Audit Criteria for Materials Testing Laboratories - Hardness (to be used for audits conducted on or after February 27, 2006)
AC7101/6 Rev A - Nadcap Audit Criteria for Materials Testing Laboratories - Corrosion (to be used for audits conducted before February 27, 2006)
AC7101/6 Rev B - Nadcap Audit Criteria for Materials Testing Laboratories - Corrosion (to be used for audits conducted on or after February 27, 2006)
AC7101/7 Rev A - Nadcap Audit Criteria for Materials Testing Laboratories - Mechanical Testing Specimen Preparation (to be used for audits conducted before February 27, 2006)
AC7101/7 Rev B - Nadcap Audit Criteria for Materials Testing Laboratories - Mechanical Testing Specimen Preparation (to be used on audits conducted on or after February 27, 2006)
AC7101/8 Rev A - Nadcap Audit Criteria for Materials Test Laboratories - Differential Thermal Analysis
AC7101/9 Rev A - Nadcap Audit Criteria for Materials Test Laboratories - Heat Treating
AC7109/5 - Nadcap Audit Criteria for Coating Evaluation Laboratory Practices
AC7109/5 Rev A - Nadcap Audit Criteria for Coating Evaluation Laboratory Practices (Req'd for all Coatings audits - except suppliers using Nadcap approved AC7109/5 Materials Testing Labs) (To be used BEFORE 29-J AN- 2007)
AC7109/5 Rev B - Nadcap Audit Criteria for Coating Evaluation Laboratory Practices (Req'd for all Coatings audits - except suppliers using Nadcap approved AC7109/5 labs) (To be used ON or AFTER 29-J AN-2007)
AC7110/13 Nadcap Audit Criteria for Metallographic Evaluation of Welds (to be used on audits conducted on or after Dec.4, 2006)
I SO/ I EC 17025 - Currently accredited by an I LAC approved source
Lab Type
per
17/20
Iter di accreditamento MTLdata 22-24/1/07 B:15/2/07
N:26/2/06
B:27/2/07
N:27/2/07
B:27/2/07
N:7/3/07
29/3/07 Prima del 31/10/07
Audit
NCR1 (Major) Open
NCR2 (minor)
NCR3 (minor)
NCR4 (Major)
NCR5 (Major) Open Open
NCR6 (Major) Open Open
NCR7 (minor) Open Open
NCR8 (minor)
NCR9 (minor)
Accreditamento
Prossimo audit B = risposta di BytestN = replica del Nadcap
Supplier days: 28Cycle Count: 3
Nota: in rosso anomalia nella replica Nadcap che annulla una prima chiusura ( ) dopo2 settimane riaprendo la NCR5 con conteggio Cycle Count lasciato invariato.
riaperta
richiusa
N:21/3/07
B:27/3/07N:27/3/07
per
18/20
Accreditamento per General Electric
Dopo accreditamento Nadcap (28/3/2007) Avio propone Bytest a General Electric come fornitore di servizi (Lab & NDT).
Initial audit MTL effettuato tra il 7 ed il 10/5 con esito favorevole (1 solo finding minore)
Accreditamento da giugno 2007.
Previsto initial audit anche per NDT.
Una volta superato initial audit di massima General Electric basa il mantenimento della qualifica sul superamento audit Nadcap.
per
19/20
Prossimi impegni col Nadcap
Initial audit per PT ed MT il 5/11/2007 (oltre ad audit RT per riaccreditamento).
Da valutare initial audit UT per fine 2008.
Audit MTL di riaccreditamento entro Luglio 2008 (compresivo di initial audit per ulteriori prove già accreditate GEAE- S400 – prove chimiche e metallografiche)
per
20/20
Conclusione
Il Nadcap è un’opportunità notevole per presentarsi sul mercato globale dotati di un adeguato accreditamento.
Per il mercato globale è fondamentale “fare sistema”.
Ma per “fare sistema” occorre un impegno maggiore e di un numero più elevato di persone.
Confidiamo che giornate come questa diano un maggiore impulso alla partecipazione attiva senza che si attendano passivamente i finding nelle proprie sedi !!!
M. Capriolo & M.F. Bianchi