2

Product line illustration for Autrol America - Industrial Pressure Transmitters

Embed Size (px)

Citation preview

Page 1: Product line illustration for Autrol America - Industrial Pressure Transmitters
Page 2: Product line illustration for Autrol America - Industrial Pressure Transmitters

Function n Flexible Sensor Input: DP, GP, AP, HP nVarious Output: 4 ~20mA , Digital Signals nProgrammable Parameters: Zero/Span, Fail-mode, Unit, Trim, etc. nSelf Diagnostic Function: Sensor, Memory A/D Converter, Power, etc. nDigital Communication with HART protocol nExplosion-proof Approval & Intrinsic Safety Approval: KOSHA, KTL, CSA,FM,

ATEX,GOST n5 Digit LCD display.

nSuperior Performance nHigh Reference Accuracy: ±0.075% of Calibrated Span nLong-Term Stability nHigh Range ability (100 : 1) nFlexibility nData Configuration with HART Configurator nZero Point Adjustment nReliability nContinuous Self-Diagnostic Function nAutomatic Ambient Temperature Compensation nFail-mode Process Function nEEPROM Write Protection nCE EMC Conformity Standards (EN50081-2, EN50082-2)

Features

FunctionnFlexible Sensor Input: GP, AP, VacuumnVarious Output: 4 ~20mA , Digital Signals

nProgrammable Parameters: Zero/Span, Fail-mode, Unit, Trim, etc. nSelf Diagnostic Function: Sensor, Memory A/D Converter, Power, etc nDigital Communication with HART protocol nExplosion-proof Approval & Intrinsic Safety Approval: KOSHA, KTL, CSA, FM,

ATEX, GOST n5 Digit LCD display.

nSuperior Performance nHigh Accuracy: ±0.075% of Calibrated Span nLong-Term Stability nHigh Rangeability (100:1) nFlexibility nData Configuration with HART Configurator nReliability nContinuous Self-Diagnostic Function nAutomatic Ambient Temperature Compensation nFail-mode Process Function nEEPROM Write Protection nCE EMC Conformity Standards (EN50081-2, EN50082-2)

Features

Functionn Flexible Sensor Input: DP, GP, AP, Vacuumn Various Output: 4 ~20mA , Digital Signalsn Self Diagnostic Function: Sensor, Memory A/D Converter, Power, etcn Qualified per IEEE STD 344-1987 and IEEE STD 323-1983, Regulatory Guide

1.180n 5 Digit LCD: Express all pressure unit and flow unit, Use 5 digit for measured value.

n Superior Performancen High Reference Accuracy: ±0.075% of Calibrated Spann Long-Term Stability: ±0.25% URL per 24 monthsn High Rangeability (100 : 1 )n Flexibilityn Data Configuration with HART Configuratorn Zero Point Adjustment & Suppressionn Reliabilityn Continuous Self-Diagnostic Functionn Automatic Ambient Temperature Compensationn Fail-mode Process Functionn EEPROM Write Protectionn Equipment Qualificationsn Environmental Qualificationn Series Qualification and EMI / REI Test

Features

FunctionnFlexible Sensor Input: GP, AP, VacuumnVarious Output: 4 ~20mA , Digital SignalsnProgrammable Parameters: Zero/Span, Fail-mode, Unit, Trim, etc.nSelf Diagnostic Function: Sensor, Memory A/D Converter, Power, etcnDigital Communication with HART protocolnExplosion-proof Approval & Intrinsic Safety Approval: KOSHA, KTL, CSA, FM,

ATEX, GOSTn5 Digit LCD display.

nSuperior PerformancenHigh AccuracynLong-Term StabilitynFlexibilitynData Configuration with HART ConfiguratornReliabilitynContinuous Self-Diagnostic FunctionnAutomatic Ambient Temperature CompensationnFail-mode Process FunctionnEEPROM Write ProtectionnCE EMC Conformity Standards (EN50081-2, EN50082-2)

Features

FunctionSensor Inputs: RTD( 2W, 3W, 4Wire), Thermocouple ( B, E, J, K, N, R, S, T types), mV ( -10 ~ 75mV), Ohm ( 0 ~ 430 Ù)

nDual Sensor Input (option) nOutput: 4 ~20mA (Analog), Digital Signals nAutomatic Compensation: Linearization of sensor input, Ambient Temperature

compensation.nSetting Various Parameters: Zero/Span, Unit, Fail-mode, Trim, etc.

nSelf Diagnostic Function: Sensor, A/D Converter, Memory, Power, etc. nDigital Communication with HART protocol nFail-mode Process function nEEPROM Write Protection nI/O Isolation: Grounded Thermocouple nCE EMC Conformity Standards (EN50081-2, EN50082-2) nFlameproof Approval and Intrinsic Safety Approval (ATT2100): KOSHA, KTL,

CSA, ATEX

FunctionnFlexible Sensor Input: GP, AP, VacuumnVarious Output: 4 ~20mA , Digital SignalsnProgrammable Parameters: Zero/Span, Fail-mode, Unit, Trim, etc.nSelf Diagnostic Function: Sensor, Memory A/D Converter, Power, etcnDigital Communication with HART protocolnExplosion-proof Approval & Intrinsic Safety Approval: KOSHA, KTL, CSA, FM,

ATEX, GOSTn5 Digit LCD display.

NSuperior PerformancenHigh AccuracynLong-Term StabilitynFlexibilitynData Configuration with HART ConfiguratornReliabilitynContinuous Self-Diagnostic FunctionnAutomatic Ambient Temperature CompensationnFail-mode Process FunctionnEEPROM Write ProtectionnCE EMC Conformity Standards (EN50081-2, EN50082-2)

Features