Page 1: Tdb vrf dvm s standard for turkey (odu 50 hz hp) ver.1.0

VRFTechnical Data BookDVM S Standard for Turkey (ODU, 50Hz, HP)

Model : AM***KXVAGH/TK

Page 2: Tdb vrf dvm s standard for turkey (odu 50 hz hp) ver.1.0

History

Version Modification Date Remark

Ver.1.0 Release DVM S 30HP Standard TDB for Turkey 16.01.12.

Page 3: Tdb vrf dvm s standard for turkey (odu 50 hz hp) ver.1.0

NomenclatureOutdoor Units

Model Names

AM(1)

140(2)

K(3)

X(4)

V(5)

A(6)

G(7)

H(8)

EUBuyer

(1) ClassificationAM DVM

(2) Capacityx 1/10 HP (3 digits)

(3) VersionF 2013

H 2014

J 2015

K 2016

(4) Product TypeX Outdoor Unit

N Indoor Unit

(5) Feature1V Inverter

M DVM S Eco

(6) Feature2A Standard + General Temp.+ Module

H High EER + Low Temp + Module

G High EER + General Temp + Module

(7) Rating VoltageE 1Ø, 220~240V, 50Hz

G 3Ø, 380~415V, 50Hz

(8) ModeH Heat Pump

R Heat Recovery

Page 4: Tdb vrf dvm s standard for turkey (odu 50 hz hp) ver.1.0

Outdoor

1 Line-up2 Specifications3 Operation limit4 Dimensional drawing5 Electrical wiring diagram6 Sound pressure level7 Sound power level8 Cycle diagram

Page 5: Tdb vrf dvm s standard for turkey (odu 50 hz hp) ver.1.0

Line-up

Outdoor Units

System Model

Capacity System Model CodeNumber

ofModules

Outdoor Unit Selection

14HP 16HP 18HP 20HP 22HP 24HP 26HP 28HP 30HP

AM140KXVAGH/TK

AM160KXVAGH/TK

AM180KXVAGH/TK

AM200KXVAGH/TK

AM220KXVAGH/TK

AM240KXVAGH/TK

AM260KXVAGH/TK

AM280KXVAGH/TK

AM300KXVAGH/TK

14HP AM140KXVAGH/TK 1

16HP AM160KXVAGH/TK 1

18HP AM180KXVAGH/TK 1

20HP AM200KXVAGH/TK 1

22HP AM220KXVAGH/TK 1

24HP AM240KXVAGH/TK 1

26HP AM260KXVAGH/TK 1

28HP AM280KXVAGH/TK 1

30HP AM300KXVAGH/TK 1

32HP AM320KXVAGH/TK 2

34HP AM340KXVAGH/TK 2

36HP AM360KXVAGH/TK 2

38HP AM380KXVAGH/TK 2

40HP AM400KXVAGH/TK 2

42HP AM420KXVAGH/TK 2

44HP AM440KXVAGH/TK 2

46HP AM460KXVAGH/TK 2

48HP AM480KXVAGH/TK 2

50HP AM500KXVAGH/TK 2

52HP AM520KXVAGH/TK 2

54HP AM540KXVAGH/TK 2

56HP AM560KXVAGH/TK 2

58HP AM580KXVAGH/TK 2

60HP AM600KXVAGH/TK 2

62HP AM620KXVAGH/TK 3

64HP AM640KXVAGH/TK 3

66HP AM660KXVAGH/TK 3

68HP AM680KXVAGH/TK 3

70HP AM700KXVAGH/TK 3

72HP AM720KXVAGH/TK 3

74HP AM740KXVAGH/TK 3

76HP AM760KXVAGH/TK 3

78HP AM780KXVAGH/TK 3

80HP AM800KXVAGH/TK 3

82HP AM820KXVAGH/TK 3

84HP AM840KXVAGH/TK 3

86HP AM860KXVAGH/TK 3

88HP AM880KXVAGH/TK 3

90HP AM900KXVAGH/TK 3

1

1

1

1

1

1

1

1

1

1 1

1 1

1 1

1 1

1 1

1 1

1 1

1 1

1 1

1 1

1 1

1 1

1 1

1 1

2

1 1 1

1 1 1

2 1

1 1 1

1 1 1

1 1 1

2 1

1 1 1

1 1 1

1 1 1

1 2

1 2

1 2

1 2

3

1

Page 6: Tdb vrf dvm s standard for turkey (odu 50 hz hp) ver.1.0

Specifications

OutdoorTypeModel NamePower Supply Ø, #, V, HzMode -

Performance

HP HP

Capacity(Nominal)

CoolingkW

Btu/h

HeatingkW

Btu/h

Power

Power Input(Nominal)

Cooling 1) kWHeating 2) kW

CurrentInput(Nominal)

Cooling 1) AHeating 2) A

MCA AMFA A

COP

EER (Nominal Cooling) -COP (Nominal Heating) -

Energy Grade--

Compressor

Type -

Output kW x n

Model Name -

Oil Type -

Fan

Type -

Output x n W

Air Flow RateCMM

l/s

ExternalStatic Max.

mmAQPa

PipingConnections

Liquid PipeØ, mmØ, inch

Gas PipeØ, mmØ, inch

Discharge Gas PipeØ, mmØ, inch

InstallationLimitation

Max. Length m

Max. Height m

Field WiringPower Source Wire mm²Transmission Cable mm²

RefrigerantType -Factory Charging kg

SoundPressure

dBAPower

ExternalDimension

New Weight kg

Shipping Weight kg

Net Dimensions (WxHxD) mm

Shipping Dimensions(WxHxD) mm

OperatingTemp.

Cooling ºCHeating ºC

DVM S(NEW) DVM S(NEW) DVM S(NEW)AM140KXVAGH/TK AM160KXVAGH/TK AM180KXVAGH/TK

3,4,380-415,50 3,4,380-415,50 3,4,380-415,50HP HP HP

14.00 16.00 18.0040.00 45.00 50.40

136,500 153,500 172,00045.00 50.40 56.70

153,500 172,000 193,50010.93 12.10 12.6010.16 11.61 11.9117.50 19.40 20.2016.30 18.60 19.1025.00 32.00 39.2040.00 40.00 50.003.66 3.72 4.004.43 4.34 4.76

ESEER 7.02 ESEER 6.81 ESEER 6.61- - -

SSC Scroll x 1 SSC Scroll x 1 SSC Scroll x 1

(6.39) (7.81) (7.81)

DS-GB066FAVBx1 DS4GJ5080FVAx1 DS4GJ5080FVAx1

PVE PVE PVEPropeller Propeller Propeller

620.0x2 620.0x2 620.0x2

255 255 290

4,250.00 4,250.00 4,833.33

8.00 8.00 8.0078.40 78.40 78.4012.70 12.70 15.881/2" 1/2" 5/8"

28.58 28.58 28.581 1/8" 1 1/8" 1 1/8"

- - -- - -

200 (220) 200 (220) 200 (220)

110 (40) 110 (40) 110 (40)

- - -0.75 ~ 1.50 0.75 ~ 1.50 0.75 ~ 1.50

R410A R410A R410A7.70 8.40 8.4061 63 6481 83 84

226.0 253.0 255.0

246.0 273.0 275.0

1,295x1,695x765 1,295x1,695x765 1,295x1,695x765

1,363x1,887x832 1,363x1,887x832 1,363x1,887x832

-5.0 ~ 48.0 -5.0 ~ 48.0 -5.0 ~ 48.0-25.0 ~ 24.0 -25.0 ~ 24.0 -25.0 ~ 24.0

* Specifications may be subject to change without prior notice.1) Nominal cooling capacities are based on;- Indoor temperature : 27°C DB, 19°C WB- Outdoor temperature : 35°C DB, 24°C WB, Equivalent refrigerant piping : 7.5m, Level differences : 0m2) Nominal heating capacities are based on;- Indoor temperature : 20°C DB, 15°C WB- Outdoor temperature : 7°C DB, 6°C WB, Equivalent refrigerant piping : 7.5m, Level differences : 0m3) Sound pressure was acquired in an anechoic room. Thus actual noise level may be different depending on the installation conditions.4) If outdoor unit is located in a higher position than indoor unit, level difference is 110m or under.(If the level difference is higher than 50m, make a decision by PDM kit installation Guide software whether the PDM kit should be installed or not.)*PDM kit: Pressure Drop Modulation kit

2

Page 7: Tdb vrf dvm s standard for turkey (odu 50 hz hp) ver.1.0

Specifications

OutdoorTypeModel NamePower Supply Ø, #, V, HzMode -

Performance

HP HP

Capacity(Nominal)

CoolingkW

Btu/h

HeatingkW

Btu/h

Power

Power Input(Nominal)

Cooling 1) kWHeating 2) kW

CurrentInput(Nominal)

Cooling 1) AHeating 2) A

MCA AMFA A

COP

EER (Nominal Cooling) -COP (Nominal Heating) -

Energy Grade--

Compressor

Type -

Output kW x n

Model Name -

Oil Type -

Fan

Type -

Output x n W

Air Flow RateCMM

l/s

ExternalStatic Max.

mmAQPa

PipingConnections

Liquid PipeØ, mmØ, inch

Gas PipeØ, mmØ, inch

Discharge Gas PipeØ, mmØ, inch

InstallationLimitation

Max. Length m

Max. Height m

Field WiringPower Source Wire mm²Transmission Cable mm²

RefrigerantType -Factory Charging kg

SoundPressure

dBAPower

ExternalDimension

New Weight kg

Shipping Weight kg

Net Dimensions (WxHxD) mm

Shipping Dimensions(WxHxD) mm

OperatingTemp.

Cooling ºCHeating ºC

DVM S(NEW) DVM S(NEW) DVM S(NEW)AM200KXVAGH/TK AM220KXVAGH/TK AM240KXVAGH/TK

3,4,380-415,50 3,4,380-415,50 3,4,380-415,50HP HP HP

20.00 22.00 24.0056.00 61.60 67.20

191,100 210,200 229,30063.00 69.30 75.60

215,000 236,500 258,00014.18 17.35 17.1013.91 16.70 17.4222.70 27.80 27.4022.30 26.80 27.9042.00 44.60 55.0075.00 75.00 75.003.95 3.55 3.934.53 4.15 4.34

ESEER 6.56 ESEER 6.25 ESEER 7.06- - -

SSC Scroll x 2 SSC Scroll x 2 SSC Scroll x 2

(5.18 x 2) (6.39 x 2) (6.39 x 2)

DS-GB052FAVBx2 DS-GB066FAVBx2 DS-GB066FAVBx2

PVE PVE PVEPropeller Propeller Propeller

620.0x2 620.0x2 620.0x2

290 290 340

4,833.33 4,833.33 5,666.67

8.00 8.00 8.0078.40 78.40 78.4015.88 15.88 15.885/8" 5/8" 5/8"

28.58 28.58 34.921 1/8" 1 1/8" 1 3/8"

- - -- - -

200 (220) 200 (220) 200 (220)

110 (40) 110 (40) 110 (40)

- - -0.75 ~ 1.50 0.75 ~ 1.50 0.75 ~ 1.50

R410A R410A R410A8.40 8.40 12.5065 65 6687 89 89

277.0 285.0 333.0

297.0 305.0 355.0

1,295x1,695x765 1,295x1,695x765 1,295x1,795x765

1,363x1,887x832 1,363x1,887x832 1,363x1,987x832

-5.0 ~ 48.0 -5.0 ~ 48.0 -5.0 ~ 48.0-25.0 ~ 24.0 -25.0 ~ 24.0 -25.0 ~ 24.0

* Specifications may be subject to change without prior notice.1) Nominal cooling capacities are based on;- Indoor temperature : 27°C DB, 19°C WB- Outdoor temperature : 35°C DB, 24°C WB, Equivalent refrigerant piping : 7.5m, Level differences : 0m2) Nominal heating capacities are based on;- Indoor temperature : 20°C DB, 15°C WB- Outdoor temperature : 7°C DB, 6°C WB, Equivalent refrigerant piping : 7.5m, Level differences : 0m3) Sound pressure was acquired in an anechoic room. Thus actual noise level may be different depending on the installation conditions.4) If outdoor unit is located in a higher position than indoor unit, level difference is 110m or under.(If the level difference is higher than 50m, make a decision by PDM kit installation Guide software whether the PDM kit should be installed or not.)*PDM kit: Pressure Drop Modulation kit

2

Page 8: Tdb vrf dvm s standard for turkey (odu 50 hz hp) ver.1.0

Specifications

OutdoorTypeModel NamePower Supply Ø, #, V, HzMode -

Performance

HP HP

Capacity(Nominal)

CoolingkW

Btu/h

HeatingkW

Btu/h

Power

Power Input(Nominal)

Cooling 1) kWHeating 2) kW

CurrentInput(Nominal)

Cooling 1) AHeating 2) A

MCA AMFA A

COP

EER (Nominal Cooling) -COP (Nominal Heating) -

Energy Grade--

Compressor

Type -

Output kW x n

Model Name -

Oil Type -

Fan

Type -

Output x n W

Air Flow RateCMM

l/s

ExternalStatic Max.

mmAQPa

PipingConnections

Liquid PipeØ, mmØ, inch

Gas PipeØ, mmØ, inch

Discharge Gas PipeØ, mmØ, inch

InstallationLimitation

Max. Length m

Max. Height m

Field WiringPower Source Wire mm²Transmission Cable mm²

RefrigerantType -Factory Charging kg

SoundPressure

dBAPower

ExternalDimension

New Weight kg

Shipping Weight kg

Net Dimensions (WxHxD) mm

Shipping Dimensions(WxHxD) mm

OperatingTemp.

Cooling ºCHeating ºC

DVM S(NEW) DVM S(NEW) DVM S(NEW)AM260KXVAGH/TK AM280KXVAGH/TK AM300KXVAGH/TK

3,4,380-415,50 3,4,380-415,50 3,4,380-415,50HP HP HP

26.00 28.00 30.0072.80 78.60 84.00

248,400 268,200 286,60081.90 88.20 94.50

279,500 301,000 322,40018.91 20.68 22.7018.00 20.18 20.5930.30 33.20 36.4028.90 32.40 33.0060.00 67.00 73.0075.00 75.00 90.003.85 3.80 3.704.55 4.37 4.59

ESEER 6.92 ESEER 6.83 ESEER 6.65- - -

SSC Scroll x 2 SSC Scroll x 2 SSC Scroll x 2

(6.39 x 2) (6.76 x 2) (7.81 x 2)

DS-GB066FAVBx2 DS-GB070FAVAx2 DS4GJ5080FVAx2

PVE PVE PVEPropeller Propeller Propeller

620.0x2 620.0x2 620.0x2

340 340 340

5,666.67 5,666.67 5,666.67

8.00 8.00 8.0078.40 78.40 78.4019.05 19.05 19.053/4" 3/4" 3/4"

34.92 34.92 34.921 3/8" 1 3/8" 1 3/8"

- - -- - -

200 (220) 200 (220) 200 (220)

110 (40) 110 (40) 110 (40)

- - -0.75 ~ 1.50 0.75 ~ 1.50 0.75 ~ 1.50

R410A R410A R410A12.50 14.00 14.00

66 69 6989 90 90

333.0 342.0 350.0

355.0 364.0 372.0

1,295x1,795x765 1,295x1,795x765 1,295x1,795x765

1,363x1,987x832 1,363x1,987x832 1,363x1,987x832

-5.0 ~ 48.0 -5.0 ~ 48.0 -5.0 ~ 48.0-25.0 ~ 24.0 -25.0 ~ 24.0 -25.0 ~ 24.0

* Specifications may be subject to change without prior notice.1) Nominal cooling capacities are based on;- Indoor temperature : 27°C DB, 19°C WB- Outdoor temperature : 35°C DB, 24°C WB, Equivalent refrigerant piping : 7.5m, Level differences : 0m2) Nominal heating capacities are based on;- Indoor temperature : 20°C DB, 15°C WB- Outdoor temperature : 7°C DB, 6°C WB, Equivalent refrigerant piping : 7.5m, Level differences : 0m3) Sound pressure was acquired in an anechoic room. Thus actual noise level may be different depending on the installation conditions.4) If outdoor unit is located in a higher position than indoor unit, level difference is 110m or under.(If the level difference is higher than 50m, make a decision by PDM kit installation Guide software whether the PDM kit should be installed or not.)*PDM kit: Pressure Drop Modulation kit

2

Page 9: Tdb vrf dvm s standard for turkey (odu 50 hz hp) ver.1.0

Specifications

OutdoorTypeModel NamePower Supply Ø, #, V, HzMode -

Performance

HP HP

Capacity(Nominal)

CoolingkW

Btu/h

HeatingkW

Btu/h

Power

Power Input(Nominal)

Cooling 1) kWHeating 2) kW

CurrentInput(Nominal)

Cooling 1) AHeating 2) A

MCA AMFA A

COP

EER (Nominal Cooling) -COP (Nominal Heating) -

Energy Grade--

Compressor

Type -

Output kW x n

Model Name -

Oil Type -

Fan

Type -

Output x n W

Air Flow RateCMM

l/s

ExternalStatic Max.

mmAQPa

PipingConnections

Liquid PipeØ, mmØ, inch

Gas PipeØ, mmØ, inch

Discharge Gas PipeØ, mmØ, inch

InstallationLimitation

Max. Length m

Max. Height m

Field WiringPower Source Wire mm²Transmission Cable mm²

RefrigerantType -Factory Charging kg

SoundPressure

dBAPower

ExternalDimension

New Weight kg

Shipping Weight kg

Net Dimensions (WxHxD) mm

Shipping Dimensions(WxHxD) mm

OperatingTemp.

Cooling ºCHeating ºC

DVM S(NEW) DVM S(NEW) DVM S(NEW)AM320KXVAGH/TK AM340KXVAGH/TK AM360KXVAGH/TK

3,4,380-415,50 3,4,380-415,50 3,4,380-415,50HP HP HP

32.00 34.00 36.0090.40 95.40 101.60

308,500 325,500 346,700101.70 107.10 114.30

347,000 365,400 390,00023.53 24.70 28.2822.07 23.52 26.8637.70 39.60 45.3035.40 37.70 43.1064.20 71.20 69.6075.00 90.00 90.003.84 3.86 3.594.61 4.55 4.26

- - -- - -

SSC Scroll x 2 SSC Scroll x 2 SSC Scroll x 3

(6.39) + (7.81) (7.81) + (7.81) (6.39) + (6.39x2)

DS-GB066FAVBx1 +DS4GJ5080FVAx1 DS4GJ5080FVAx2 DS-GB066FAVBx3

PVE PVE PVEPropeller Propeller Propeller

(620.0x2)x2 (620.0x2)x2 (620.0x2)x2

255.0 + 290.0 255.0 + 290.0 255.0 + 290.0

4,250.0 + 4,833.3 4,250.0 + 4,833.3 4,250.0 + 4,833.3

8.00 8.00 8.0078.40 78.40 78.4019.05 19.05 19.053/4" 3/4" 3/4"

34.92 34.92 41.281 3/8" 1 3/8" 1 5/8"

- - -- - -

200 (220) 200 (220) 200 (220)

110 (40) 110 (40) 110 (40)

- - -0.75 ~ 1.50 0.75 ~ 1.50 0.75 ~ 1.50

R410A R410A R410A16.10 16.80 16.10

- - -- - -

226.0 + 255.0 253.0 + 255.0 226.0 + 285.0

246.0 + 275.0 273.0 + 275.0 246.0 + 305.0

(1,295x1,695x765)x2 (1,295x1,695x765)x2 (1,295x1,695x765)x2

(1,363x1,887x832)x2 (1,363x1,887x832)x2 (1,363x1,887x832)x2

-5.0 ~ 48.0 -5.0 ~ 48.0 -5.0 ~ 48.0-25.0 ~ 24.0 -25.0 ~ 24.0 -25.0 ~ 24.0

* Specifications may be subject to change without prior notice.1) Nominal cooling capacities are based on;- Indoor temperature : 27°C DB, 19°C WB- Outdoor temperature : 35°C DB, 24°C WB, Equivalent refrigerant piping : 7.5m, Level differences : 0m2) Nominal heating capacities are based on;- Indoor temperature : 20°C DB, 15°C WB- Outdoor temperature : 7°C DB, 6°C WB, Equivalent refrigerant piping : 7.5m, Level differences : 0m3) Sound pressure was acquired in an anechoic room. Thus actual noise level may be different depending on the installation conditions.4) If outdoor unit is located in a higher position than indoor unit, level difference is 110m or under.(If the level difference is higher than 50m, make a decision by PDM kit installation Guide software whether the PDM kit should be installed or not.)*PDM kit: Pressure Drop Modulation kit

2

Page 10: Tdb vrf dvm s standard for turkey (odu 50 hz hp) ver.1.0

Specifications

OutdoorTypeModel NamePower Supply Ø, #, V, HzMode -

Performance

HP HP

Capacity(Nominal)

CoolingkW

Btu/h

HeatingkW

Btu/h

Power

Power Input(Nominal)

Cooling 1) kWHeating 2) kW

CurrentInput(Nominal)

Cooling 1) AHeating 2) A

MCA AMFA A

COP

EER (Nominal Cooling) -COP (Nominal Heating) -

Energy Grade--

Compressor

Type -

Output kW x n

Model Name -

Oil Type -

Fan

Type -

Output x n W

Air Flow RateCMM

l/s

ExternalStatic Max.

mmAQPa

PipingConnections

Liquid PipeØ, mmØ, inch

Gas PipeØ, mmØ, inch

Discharge Gas PipeØ, mmØ, inch

InstallationLimitation

Max. Length m

Max. Height m

Field WiringPower Source Wire mm²Transmission Cable mm²

RefrigerantType -Factory Charging kg

SoundPressure

dBAPower

ExternalDimension

New Weight kg

Shipping Weight kg

Net Dimensions (WxHxD) mm

Shipping Dimensions(WxHxD) mm

OperatingTemp.

Cooling ºCHeating ºC

DVM S(NEW) DVM S(NEW) DVM S(NEW)AM380KXVAGH/TK AM400KXVAGH/TK AM420KXVAGH/TK

3,4,380-415,50 3,4,380-415,50 3,4,380-415,50HP HP HP

38.00 40.00 42.00106.60 112.00 117.60

363,700 382,200 401,300119.70 126.00 132.30

408,400 429,900 451,40029.45 29.95 31.5328.31 28.61 30.6147.20 48.00 50.5045.40 45.90 49.1076.60 83.80 86.6090.00 100.00 100.003.62 3.74 3.734.23 4.40 4.32

- - -- - -

SSC Scroll x 3 SSC Scroll x 3 SSC Scroll x 4

(7.81) + (6.39x2) (7.81) + (6.39x2) (5.18x2) + (6.39x2)

DS4GJ5080FVAx1 + DS-GB066FAVBx2

DS4GJ5080FVAx1 + DS-GB066FAVBx2

DS-GB052FAVBx2 + DS-GB066FAVBx2

PVE PVE PVEPropeller Propeller Propeller

(620.0x2)x2 (620.0x2)x2 (620.0x2)x2

255.0 + 290.0 290.0x2 290.0x2

4,250.0 + 4,833.3 4,833.3x2 4,833.3x2

8.00 8.00 8.0078.40 78.40 78.4019.05 19.05 19.053/4" 3/4" 3/4"

41.28 41.28 41.281 5/8" 1 5/8" 1 5/8"

- - -- - -

200 (220) 200 (220) 200 (220)

110 (40) 110 (40) 110 (40)

- - -0.75 ~ 1.50 0.75 ~ 1.50 0.75 ~ 1.50

R410A R410A R410A16.80 16.80 16.80

- - -- - -

253.0 + 285.0 255.0 + 285.0 277.0 + 285.0

273.0 + 305.0 275.0 + 305.0 297.0 + 305.0

(1,295x1,695x765)x2 (1,295x1,695x765)x2 (1,295x1,695x765)x2

(1,363x1,887x832)x2 (1,363x1,887x832)x2 (1,363x1,887x832)x2

-5.0 ~ 48.0 -5.0 ~ 48.0 -5.0 ~ 48.0-25.0 ~ 24.0 -25.0 ~ 24.0 -25.0 ~ 24.0

* Specifications may be subject to change without prior notice.1) Nominal cooling capacities are based on;- Indoor temperature : 27°C DB, 19°C WB- Outdoor temperature : 35°C DB, 24°C WB, Equivalent refrigerant piping : 7.5m, Level differences : 0m2) Nominal heating capacities are based on;- Indoor temperature : 20°C DB, 15°C WB- Outdoor temperature : 7°C DB, 6°C WB, Equivalent refrigerant piping : 7.5m, Level differences : 0m3) Sound pressure was acquired in an anechoic room. Thus actual noise level may be different depending on the installation conditions.4) If outdoor unit is located in a higher position than indoor unit, level difference is 110m or under.(If the level difference is higher than 50m, make a decision by PDM kit installation Guide software whether the PDM kit should be installed or not.)*PDM kit: Pressure Drop Modulation kit

2

Page 11: Tdb vrf dvm s standard for turkey (odu 50 hz hp) ver.1.0

Specifications

OutdoorTypeModel NamePower Supply Ø, #, V, HzMode -

Performance

HP HP

Capacity(Nominal)

CoolingkW

Btu/h

HeatingkW

Btu/h

Power

Power Input(Nominal)

Cooling 1) kWHeating 2) kW

CurrentInput(Nominal)

Cooling 1) AHeating 2) A

MCA AMFA A

COP

EER (Nominal Cooling) -COP (Nominal Heating) -

Energy Grade--

Compressor

Type -

Output kW x n

Model Name -

Oil Type -

Fan

Type -

Output x n W

Air Flow RateCMM

l/s

ExternalStatic Max.

mmAQPa

PipingConnections

Liquid PipeØ, mmØ, inch

Gas PipeØ, mmØ, inch

Discharge Gas PipeØ, mmØ, inch

InstallationLimitation

Max. Length m

Max. Height m

Field WiringPower Source Wire mm²Transmission Cable mm²

RefrigerantType -Factory Charging kg

SoundPressure

dBAPower

ExternalDimension

New Weight kg

Shipping Weight kg

Net Dimensions (WxHxD) mm

Shipping Dimensions(WxHxD) mm

OperatingTemp.

Cooling ºCHeating ºC

DVM S(NEW) DVM S(NEW) DVM S(NEW)AM440KXVAGH/TK AM460KXVAGH/TK AM480KXVAGH/TK

3,4,380-415,50 3,4,380-415,50 3,4,380-415,50HP HP HP

44.00 46.00 48.00124.00 129.00 134.40

423,100 440,200 458,600139.50 144.90 151.20

476,000 494,400 515,90033.63 34.80 35.3030.75 32.20 32.5053.90 55.80 56.6049.30 51.60 52.1098.00 105.00 112.20

125.00 125.00 125.003.69 3.71 3.814.54 4.50 4.65

- - -- - -

SSC Scroll x 3 SSC Scroll x 3 SSC Scroll x 3

(6.39) + (7.81x2) (7.81) + (7.81x2) (7.81) + (7.81x2)

DS-GB066FAVBx1 +DS4GJ5080FVAx2 DS4GJ5080FVAx3 DS4GJ5080FVAx3

PVE PVE PVEPropeller Propeller Propeller

(620.0x2)x2 (620.0x2)x2 (620.0x2)x2

255.0 + 340.0 255.0 + 340.0 290.0 + 340.0

4,250.0 + 5,666.7 4,250.0 + 5,666.7 4,833.3 + 5,666.7

8.00 8.00 8.0078.40 78.40 78.4019.05 19.05 19.053/4" 3/4" 3/4"

41.28 41.28 41.281 5/8" 1 5/8" 1 5/8"

- - -- - -

200 (220) 200 (220) 200 (220)

110 (40) 110 (40) 110 (40)

- - -0.75 ~ 1.50 0.75 ~ 1.50 0.75 ~ 1.50

R410A R410A R410A21.70 22.40 22.40

- - -- - -

226.0 + 350.0 253.0 + 350.0 255.0 + 350.0

246.0 + 372.0 273.0 + 372.0 275.0 + 372.0

1,295x1,695x765 +1,295x1,795x765

1,295x1,695x765 +1,295x1,795x765

1,295x1,695x765 +1,295x1,795x765

1,363x1,887x832 +1,363x1,987x832

1,363x1,887x832 +1,363x1,987x832

1,363x1,887x832 +1,363x1,987x832

-5.0 ~ 48.0 -5.0 ~ 48.0 -5.0 ~ 48.0-25.0 ~ 24.0 -25.0 ~ 24.0 -25.0 ~ 24.0

* Specifications may be subject to change without prior notice.1) Nominal cooling capacities are based on;- Indoor temperature : 27°C DB, 19°C WB- Outdoor temperature : 35°C DB, 24°C WB, Equivalent refrigerant piping : 7.5m, Level differences : 0m2) Nominal heating capacities are based on;- Indoor temperature : 20°C DB, 15°C WB- Outdoor temperature : 7°C DB, 6°C WB, Equivalent refrigerant piping : 7.5m, Level differences : 0m3) Sound pressure was acquired in an anechoic room. Thus actual noise level may be different depending on the installation conditions.4) If outdoor unit is located in a higher position than indoor unit, level difference is 110m or under.(If the level difference is higher than 50m, make a decision by PDM kit installation Guide software whether the PDM kit should be installed or not.)*PDM kit: Pressure Drop Modulation kit

2

Page 12: Tdb vrf dvm s standard for turkey (odu 50 hz hp) ver.1.0

Specifications

OutdoorTypeModel NamePower Supply Ø, #, V, HzMode -

Performance

HP HP

Capacity(Nominal)

CoolingkW

Btu/h

HeatingkW

Btu/h

Power

Power Input(Nominal)

Cooling 1) kWHeating 2) kW

CurrentInput(Nominal)

Cooling 1) AHeating 2) A

MCA AMFA A

COP

EER (Nominal Cooling) -COP (Nominal Heating) -

Energy Grade--

Compressor

Type -

Output kW x n

Model Name -

Oil Type -

Fan

Type -

Output x n W

Air Flow RateCMM

l/s

ExternalStatic Max.

mmAQPa

PipingConnections

Liquid PipeØ, mmØ, inch

Gas PipeØ, mmØ, inch

Discharge Gas PipeØ, mmØ, inch

InstallationLimitation

Max. Length m

Max. Height m

Field WiringPower Source Wire mm²Transmission Cable mm²

RefrigerantType -Factory Charging kg

SoundPressure

dBAPower

ExternalDimension

New Weight kg

Shipping Weight kg

Net Dimensions (WxHxD) mm

Shipping Dimensions(WxHxD) mm

OperatingTemp.

Cooling ºCHeating ºC

DVM S(NEW) DVM S(NEW) DVM S(NEW)AM500KXVAGH/TK AM520KXVAGH/TK AM540KXVAGH/TK

3,4,380-415,50 3,4,380-415,50 3,4,380-415,50HP HP HP

50.00 52.00 54.00140.00 145.60 151.20

477,700 496,800 515,900157.50 163.80 170.10

537,400 558,900 580,40036.88 40.05 39.8034.50 37.29 38.0159.10 64.20 63.8055.30 59.80 60.90

115.00 117.60 128.00150.00 150.00 150.00

3.80 3.64 3.804.57 4.39 4.48

- - -- - -

SSC Scroll x 4 SSC Scroll x 4 SSC Scroll x 4

(5.18x2) + (7.81x2) (6.39x2) + (7.81x2) (6.39x2) + (7.81x2)

DS-GB052FAVBx2 +DS4GJ5080FVAx2

DS-GB066FAVBx2 +DS4GJ5080FVAx2

DS-GB066FAVBx2 +DS4GJ5080FVAx2

PVE PVE PVEPropeller Propeller Propeller

(620.0x2)x2 (620.0x2)x2 (620.0x2)x2

290.0 + 340.0 290.0 + 340.0 340.0x2

4,833.3 + 5,666.7 4,833.3 + 5,666.7 5,666.7x2

8.00 8.00 8.0078.40 78.40 78.4019.05 19.05 19.053/4" 3/4" 3/4"

41.28 41.28 41.281 5/8" 1 5/8" 1 5/8"

- - -- - -

200 (220) 200 (220) 200 (220)

110 (40) 110 (40) 110 (40)

- - -0.75 ~ 1.50 0.75 ~ 1.50 0.75 ~ 1.50

R410A R410A R410A22.40 22.40 26.50

- - -- - -

277.0 + 350.0 285.0 + 350.0 333.0 + 350.0

297.0 + 372.0 305.0 + 372.0 355.0 + 372.0

1,295x1,695x765 +1,295x1,795x765

1,295x1,695x765 +1,295x1,795x765 (1,295x1,795x765)x2

1,363x1,887x832 +1,363x1,987x832

1,363x1,887x832 +1,363x1,987x832 (1,363x1,987x832)x2

-5.0 ~ 48.0 -5.0 ~ 48.0 -5.0 ~ 48.0-25.0 ~ 24.0 -25.0 ~ 24.0 -25.0 ~ 24.0

* Specifications may be subject to change without prior notice.1) Nominal cooling capacities are based on;- Indoor temperature : 27°C DB, 19°C WB- Outdoor temperature : 35°C DB, 24°C WB, Equivalent refrigerant piping : 7.5m, Level differences : 0m2) Nominal heating capacities are based on;- Indoor temperature : 20°C DB, 15°C WB- Outdoor temperature : 7°C DB, 6°C WB, Equivalent refrigerant piping : 7.5m, Level differences : 0m3) Sound pressure was acquired in an anechoic room. Thus actual noise level may be different depending on the installation conditions.4) If outdoor unit is located in a higher position than indoor unit, level difference is 110m or under.(If the level difference is higher than 50m, make a decision by PDM kit installation Guide software whether the PDM kit should be installed or not.)*PDM kit: Pressure Drop Modulation kit

2

Page 13: Tdb vrf dvm s standard for turkey (odu 50 hz hp) ver.1.0

Specifications

OutdoorTypeModel NamePower Supply Ø, #, V, HzMode -

Performance

HP HP

Capacity(Nominal)

CoolingkW

Btu/h

HeatingkW

Btu/h

Power

Power Input(Nominal)

Cooling 1) kWHeating 2) kW

CurrentInput(Nominal)

Cooling 1) AHeating 2) A

MCA AMFA A

COP

EER (Nominal Cooling) -COP (Nominal Heating) -

Energy Grade--

Compressor

Type -

Output kW x n

Model Name -

Oil Type -

Fan

Type -

Output x n W

Air Flow RateCMM

l/s

ExternalStatic Max.

mmAQPa

PipingConnections

Liquid PipeØ, mmØ, inch

Gas PipeØ, mmØ, inch

Discharge Gas PipeØ, mmØ, inch

InstallationLimitation

Max. Length m

Max. Height m

Field WiringPower Source Wire mm²Transmission Cable mm²

RefrigerantType -Factory Charging kg

SoundPressure

dBAPower

ExternalDimension

New Weight kg

Shipping Weight kg

Net Dimensions (WxHxD) mm

Shipping Dimensions(WxHxD) mm

OperatingTemp.

Cooling ºCHeating ºC

DVM S(NEW) DVM S(NEW) DVM S(NEW)AM560KXVAGH/TK AM580KXVAGH/TK AM600KXVAGH/TK

3,4,380-415,50 3,4,380-415,50 3,4,380-415,50HP HP HP

56.00 58.00 60.00156.80 162.60 168.00

535,000 554,800 573,200176.40 182.70 189.00

601,900 623,400 644,90041.61 43.39 45.4138.59 40.77 41.1866.70 69.60 72.8061.90 65.40 66.00

133.00 140.00 146.00150.00 200.00 200.00

3.77 3.75 3.704.57 4.48 4.59

- - -- - -

SSC Scroll x 4 SSC Scroll x 4 SSC Scroll x 4

(6.39x2) + (7.81x2) (6.76x2) + (7.81x2) (7.81x2)x2

DS-GB066FAVBx2 +DS4GJ5080FVAx2

DS-GB070FAVAx2 +DS4GJ5080FVAx2 DS4GJ5080FVAx4

PVE PVE PVEPropeller Propeller Propeller

(620.0x2)x2 (620.0x2)x2 (620.0x2)x2

340.0x2 340.0x2 340.0x2

5,666.7x2 5,666.7x2 5,666.7x2

8.00 8.00 8.0078.40 78.40 78.4019.05 19.05 19.053/4" 3/4" 3/4"

41.28 41.28 41.281 5/8" 1 5/8" 1 5/8"

- - -- - -

200 (220) 200 (220) 200 (220)

110 (40) 110 (40) 110 (40)

- - -0.75 ~ 1.50 0.75 ~ 1.50 0.75 ~ 1.50

R410A R410A R410A26.50 28.00 28.00

- - -- - -

333.0 + 350.0 342.0 + 350.0 350.0x2

355.0 + 372.0 364.0 + 372.0 372.0x2

(1,295x1,795x765)x2 (1,295x1,795x765)x2 (1,295x1,795x765)x2

(1,363x1,987x832)x2 (1,363x1,987x832)x2 (1,363x1,987x832)x2

-5.0 ~ 48.0 -5.0 ~ 48.0 -5.0 ~ 48.0-25.0 ~ 24.0 -25.0 ~ 24.0 -25.0 ~ 24.0

* Specifications may be subject to change without prior notice.1) Nominal cooling capacities are based on;- Indoor temperature : 27°C DB, 19°C WB- Outdoor temperature : 35°C DB, 24°C WB, Equivalent refrigerant piping : 7.5m, Level differences : 0m2) Nominal heating capacities are based on;- Indoor temperature : 20°C DB, 15°C WB- Outdoor temperature : 7°C DB, 6°C WB, Equivalent refrigerant piping : 7.5m, Level differences : 0m3) Sound pressure was acquired in an anechoic room. Thus actual noise level may be different depending on the installation conditions.4) If outdoor unit is located in a higher position than indoor unit, level difference is 110m or under.(If the level difference is higher than 50m, make a decision by PDM kit installation Guide software whether the PDM kit should be installed or not.)*PDM kit: Pressure Drop Modulation kit

2

Page 14: Tdb vrf dvm s standard for turkey (odu 50 hz hp) ver.1.0

Specifications

OutdoorTypeModel NamePower Supply Ø, #, V, HzMode -

Performance

HP HP

Capacity(Nominal)

CoolingkW

Btu/h

HeatingkW

Btu/h

Power

Power Input(Nominal)

Cooling 1) kWHeating 2) kW

CurrentInput(Nominal)

Cooling 1) AHeating 2) A

MCA AMFA A

COP

EER (Nominal Cooling) -COP (Nominal Heating) -

Energy Grade--

Compressor

Type -

Output kW x n

Model Name -

Oil Type -

Fan

Type -

Output x n W

Air Flow RateCMM

l/s

ExternalStatic Max.

mmAQPa

PipingConnections

Liquid PipeØ, mmØ, inch

Gas PipeØ, mmØ, inch

Discharge Gas PipeØ, mmØ, inch

InstallationLimitation

Max. Length m

Max. Height m

Field WiringPower Source Wire mm²Transmission Cable mm²

RefrigerantType -Factory Charging kg

SoundPressure

dBAPower

ExternalDimension

New Weight kg

Shipping Weight kg

Net Dimensions (WxHxD) mm

Shipping Dimensions(WxHxD) mm

OperatingTemp.

Cooling ºCHeating ºC

DVM S(NEW) DVM S(NEW) DVM S(NEW)AM620KXVAGH/TK AM640KXVAGH/TK AM660KXVAGH/TK

3,4,380-415,50 3,4,380-415,50 3,4,380-415,50HP HP HP

62.00 64.00 66.00174.40 179.40 184.80

595,100 612,100 630,600196.20 201.60 207.90

669,500 687,900 709,40046.23 47.40 47.9042.66 44.11 44.4174.10 76.00 76.8068.40 70.70 71.20

137.20 144.20 151.40200.00 200.00 200.00

3.77 3.78 3.864.60 4.57 4.68

- - -- - -

SSC Scroll x 4 SSC Scroll x 4 SSC Scroll x 4

(6.39) + (7.81) + (7.81x2) (7.81) + (7.81) + (7.81x2) (7.81)x2 + (7.81x2)

DS-GB066FAVBx1 +DS4GJ5080FVAx3 DS4GJ5080FVAx4 DS4GJ5080FVAx4

PVE PVE PVEPropeller Propeller Propeller

(620.0x2)x3 (620.0x2)x3 (620.0x2)x3

255.0 + 290.0 + 340.0 255.0 + 290.0 + 340.0 290.0x2 + 340.0

4,250.0 + 4,833.3 + 5,666.7 4,250.0 + 4,833.3 + 5,666.7 4,833.3x2 + 5,666.7

8.00 8.00 8.0078.40 78.40 78.4022.22 22.22 22.227/8" 7/8" 7/8"

53.98 53.98 53.982 1/8" 2 1/8" 2 1/8"

- - -- - -

200 (220) 200 (220) 200 (220)

110 (40) 110 (40) 110 (40)

- - -0.75 ~ 1.50 0.75 ~ 1.50 0.75 ~ 1.50

R410A R410A R410A30.10 30.80 30.80

- - -- - -

226.0 + 255.0 + 350.0 253.0 + 255.0 + 350.0 255.0x2 + 350.0

246.0 + 275.0 + 372.0 273.0 + 275.0 + 372.0 275.0x2 + 372.0

(1,295x1,695x765)x2 +1,295x1,795x765

(1,295x1,695x765)x2 +1,295x1,795x765

(1,295x1,695x765)x2 +1,295x1,795x765

(1,363x1,887x832)x2 +1,363x1,987x832

(1,363x1,887x832)x2 +1,363x1,987x832

(1,363x1,887x832)x2 +1,363x1,987x832

-5.0 ~ 48.0 -5.0 ~ 48.0 -5.0 ~ 48.0-25.0 ~ 24.0 -25.0 ~ 24.0 -25.0 ~ 24.0

* Specifications may be subject to change without prior notice.1) Nominal cooling capacities are based on;- Indoor temperature : 27°C DB, 19°C WB- Outdoor temperature : 35°C DB, 24°C WB, Equivalent refrigerant piping : 7.5m, Level differences : 0m2) Nominal heating capacities are based on;- Indoor temperature : 20°C DB, 15°C WB- Outdoor temperature : 7°C DB, 6°C WB, Equivalent refrigerant piping : 7.5m, Level differences : 0m3) Sound pressure was acquired in an anechoic room. Thus actual noise level may be different depending on the installation conditions.4) If outdoor unit is located in a higher position than indoor unit, level difference is 110m or under.(If the level difference is higher than 50m, make a decision by PDM kit installation Guide software whether the PDM kit should be installed or not.)*PDM kit: Pressure Drop Modulation kit

2

Page 15: Tdb vrf dvm s standard for turkey (odu 50 hz hp) ver.1.0

Specifications

OutdoorTypeModel NamePower Supply Ø, #, V, HzMode -

Performance

HP HP

Capacity(Nominal)

CoolingkW

Btu/h

HeatingkW

Btu/h

Power

Power Input(Nominal)

Cooling 1) kWHeating 2) kW

CurrentInput(Nominal)

Cooling 1) AHeating 2) A

MCA AMFA A

COP

EER (Nominal Cooling) -COP (Nominal Heating) -

Energy Grade--

Compressor

Type -

Output kW x n

Model Name -

Oil Type -

Fan

Type -

Output x n W

Air Flow RateCMM

l/s

ExternalStatic Max.

mmAQPa

PipingConnections

Liquid PipeØ, mmØ, inch

Gas PipeØ, mmØ, inch

Discharge Gas PipeØ, mmØ, inch

InstallationLimitation

Max. Length m

Max. Height m

Field WiringPower Source Wire mm²Transmission Cable mm²

RefrigerantType -Factory Charging kg

SoundPressure

dBAPower

ExternalDimension

New Weight kg

Shipping Weight kg

Net Dimensions (WxHxD) mm

Shipping Dimensions(WxHxD) mm

OperatingTemp.

Cooling ºCHeating ºC

DVM S(NEW) DVM S(NEW) DVM S(NEW)AM680KXVAGH/TK AM700KXVAGH/TK AM720KXVAGH/TK

3,4,380-415,50 3,4,380-415,50 3,4,380-415,50HP HP HP

68.00 70.00 72.00190.40 196.00 201.60

649,700 668,800 687,900214.20 220.50 226.80

730,900 752,400 773,90049.48 52.65 54.2346.41 49.20 51.1979.30 84.40 86.9074.40 78.90 82.10

154.20 156.80 159.60200.00 200.00 200.00

3.85 3.72 3.724.62 4.48 4.43

- - -- - -

SSC Scroll x 5 SSC Scroll x 5 SSC Scroll x 6

(7.81) + (5.18x2) + (7.81x2) (7.81) + (6.39x2) + (7.81x2) (5.18x2) + (6.39x2) + (7.81x2)

DS4GJ5080FVAx3 + DS-GB052FAVBx2

DS4GJ5080FVAx3 + DS-GB066FAVBx2

DS-GB052FAVBx2 + DS-GB066FAVBx2 +

DS4GJ5080FVAx2PVE PVE PVE

Propeller Propeller Propeller

(620.0x2)x3 (620.0x2)x3 (620.0x2)x3

290.0x2 + 340.0 290.0x2 + 340.0 290.0x2 + 340.0

4,833.3x2 + 5,666.7 4,833.3x2 + 5,666.7 4,833.3x2 + 5,666.7

8.00 8.00 8.0078.40 78.40 78.4022.22 22.22 22.227/8" 7/8" 7/8"

53.98 53.98 53.982 1/8" 2 1/8" 2 1/8"

- - -- - -

200 (220) 200 (220) 200 (220)

110 (40) 110 (40) 110 (40)

- - -0.75 ~ 1.50 0.75 ~ 1.50 0.75 ~ 1.50

R410A R410A R410A30.80 30.80 30.80

- - -- - -

255.0 + 277.0 + 350.0 255.0 + 285.0 + 350.0 277.0 + 285.0 + 350.0

275.0 + 297.0 + 372.0 275.0 + 305.0 + 372.0 297.0 + 305.0 + 372.0

(1,295x1,695x765)x2 +1,295x1,795x765

(1,295x1,695x765)x2 +1,295x1,795x765

(1,295x1,695x765)x2 +1,295x1,795x765

(1,363x1,887x832)x2 +1,363x1,987x832

(1,363x1,887x832)x2 +1,363x1,987x832

(1,363x1,887x832)x2 +1,363x1,987x832

-5.0 ~ 48.0 -5.0 ~ 48.0 -5.0 ~ 48.0-25.0 ~ 24.0 -25.0 ~ 24.0 -25.0 ~ 24.0

* Specifications may be subject to change without prior notice.1) Nominal cooling capacities are based on;- Indoor temperature : 27°C DB, 19°C WB- Outdoor temperature : 35°C DB, 24°C WB, Equivalent refrigerant piping : 7.5m, Level differences : 0m2) Nominal heating capacities are based on;- Indoor temperature : 20°C DB, 15°C WB- Outdoor temperature : 7°C DB, 6°C WB, Equivalent refrigerant piping : 7.5m, Level differences : 0m3) Sound pressure was acquired in an anechoic room. Thus actual noise level may be different depending on the installation conditions.4) If outdoor unit is located in a higher position than indoor unit, level difference is 110m or under.(If the level difference is higher than 50m, make a decision by PDM kit installation Guide software whether the PDM kit should be installed or not.)*PDM kit: Pressure Drop Modulation kit

2

Page 16: Tdb vrf dvm s standard for turkey (odu 50 hz hp) ver.1.0

Specifications

OutdoorTypeModel NamePower Supply Ø, #, V, HzMode -

Performance

HP HP

Capacity(Nominal)

CoolingkW

Btu/h

HeatingkW

Btu/h

Power

Power Input(Nominal)

Cooling 1) kWHeating 2) kW

CurrentInput(Nominal)

Cooling 1) AHeating 2) A

MCA AMFA A

COP

EER (Nominal Cooling) -COP (Nominal Heating) -

Energy Grade--

Compressor

Type -

Output kW x n

Model Name -

Oil Type -

Fan

Type -

Output x n W

Air Flow RateCMM

l/s

ExternalStatic Max.

mmAQPa

PipingConnections

Liquid PipeØ, mmØ, inch

Gas PipeØ, mmØ, inch

Discharge Gas PipeØ, mmØ, inch

InstallationLimitation

Max. Length m

Max. Height m

Field WiringPower Source Wire mm²Transmission Cable mm²

RefrigerantType -Factory Charging kg

SoundPressure

dBAPower

ExternalDimension

New Weight kg

Shipping Weight kg

Net Dimensions (WxHxD) mm

Shipping Dimensions(WxHxD) mm

OperatingTemp.

Cooling ºCHeating ºC

DVM S(NEW) DVM S(NEW) DVM S(NEW)AM740KXVAGH/TK AM760KXVAGH/TK AM780KXVAGH/TK

3,4,380-415,50 3,4,380-415,50 3,4,380-415,50HP HP HP

74.00 76.00 78.00207.20 212.80 218.40

707,000 726,100 745,200233.10 239.40 245.70

795,400 816,900 838,40057.41 57.15 58.9653.99 54.71 55.2992.00 91.60 94.5086.60 87.70 88.70

162.20 172.60 177.60200.00 200.00 200.00

3.61 3.72 3.704.32 4.38 4.44

- - -- - -

SSC Scroll x 6 SSC Scroll x 6 SSC Scroll x 6

(6.39x2)x2 + (7.81x2) (6.39x2) + (6.39x2) + (7.81x2) (6.39x2) + (6.39x2) + (7.81x2)

DS-GB066FAVBx4 +DS4GJ5080FVAx2

DS-GB066FAVBx4 +DS4GJ5080FVAx2

DS-GB066FAVBx4 +DS4GJ5080FVAx2

PVE PVE PVEPropeller Propeller Propeller

(620.0x2)x3 (620.0x2)x3 (620.0x2)x3

290.0x2 + 340.0 290.0 + 340.0x2 290.0 + 340.0x2

4,833.3x2 + 5,666.7 4,833.3 + 5,666.7x2 4,833.3 + 5,666.7x2

8.00 8.00 8.0078.40 78.40 78.4022.22 22.22 22.227/8" 7/8" 7/8"

53.98 53.98 53.982 1/8" 2 1/8" 2 1/8"

- - -- - -

200 (220) 200 (220) 200 (220)

110 (40) 110 (40) 110 (40)

- - -0.75 ~ 1.50 0.75 ~ 1.50 0.75 ~ 1.50

R410A R410A R410A30.80 34.90 34.90

- - -- - -

285.0x2 + 350.0 285.0 + 333.0 + 350.0 285.0 + 333.0 + 350.0

305.0x2 + 372.0 305.0 + 355.0 + 372.0 305.0 + 355.0 + 372.0

(1,295x1,695x765)x2 +1,295x1,795x765

1,295x1,695x765 +(1,295x1,795x765)x2

1,295x1,695x765 +(1,295x1,795x765)x2

(1,363x1,887x832)x2 +1,363x1,987x832

1,363x1,887x832 +(1,363x1,987x832)x2

1,363x1,887x832 +(1,363x1,987x832)x2

-5.0 ~ 48.0 -5.0 ~ 48.0 -5.0 ~ 48.0-25.0 ~ 24.0 -25.0 ~ 24.0 -25.0 ~ 24.0

* Specifications may be subject to change without prior notice.1) Nominal cooling capacities are based on;- Indoor temperature : 27°C DB, 19°C WB- Outdoor temperature : 35°C DB, 24°C WB, Equivalent refrigerant piping : 7.5m, Level differences : 0m2) Nominal heating capacities are based on;- Indoor temperature : 20°C DB, 15°C WB- Outdoor temperature : 7°C DB, 6°C WB, Equivalent refrigerant piping : 7.5m, Level differences : 0m3) Sound pressure was acquired in an anechoic room. Thus actual noise level may be different depending on the installation conditions.4) If outdoor unit is located in a higher position than indoor unit, level difference is 110m or under.(If the level difference is higher than 50m, make a decision by PDM kit installation Guide software whether the PDM kit should be installed or not.)*PDM kit: Pressure Drop Modulation kit

2

Page 17: Tdb vrf dvm s standard for turkey (odu 50 hz hp) ver.1.0

Specifications

OutdoorTypeModel NamePower Supply Ø, #, V, HzMode -

Performance

HP HP

Capacity(Nominal)

CoolingkW

Btu/h

HeatingkW

Btu/h

Power

Power Input(Nominal)

Cooling 1) kWHeating 2) kW

CurrentInput(Nominal)

Cooling 1) AHeating 2) A

MCA AMFA A

COP

EER (Nominal Cooling) -COP (Nominal Heating) -

Energy Grade--

Compressor

Type -

Output kW x n

Model Name -

Oil Type -

Fan

Type -

Output x n W

Air Flow RateCMM

l/s

ExternalStatic Max.

mmAQPa

PipingConnections

Liquid PipeØ, mmØ, inch

Gas PipeØ, mmØ, inch

Discharge Gas PipeØ, mmØ, inch

InstallationLimitation

Max. Length m

Max. Height m

Field WiringPower Source Wire mm²Transmission Cable mm²

RefrigerantType -Factory Charging kg

SoundPressure

dBAPower

ExternalDimension

New Weight kg

Shipping Weight kg

Net Dimensions (WxHxD) mm

Shipping Dimensions(WxHxD) mm

OperatingTemp.

Cooling ºCHeating ºC

DVM S(NEW) DVM S(NEW) DVM S(NEW)AM800KXVAGH/TK AM820KXVAGH/TK AM840KXVAGH/TK

3,4,380-415,50 3,4,380-415,50 3,4,380-415,50HP HP HP

80.00 82.00 84.00224.20 229.60 235.20

765,000 783,400 802,500252.00 258.30 264.60

859,900 881,400 902,90060.74 62.76 62.5057.47 57.88 58.6097.40 100.60 100.2092.20 92.80 93.90

184.60 190.60 201.00250.00 250.00 250.00

3.69 3.66 3.764.38 4.46 4.52

- - -- - -

SSC Scroll x 6 SSC Scroll x 6 SSC Scroll x 6

(6.39x2) + (6.76x2) + (7.81x2) (6.39x2) + (7.81x2)x2 (6.39x2) + (7.81x2)x2

DS-GB066FAVBx2 + DS-GB070FAVAx2 +

DS4GJ5080FVAx2DS-GB066FAVBx2 +DS4GJ5080FVAx4

DS-GB066FAVBx2 +DS4GJ5080FVAx4

PVE PVE PVEPropeller Propeller Propeller

(620.0x2)x3 (620.0x2)x3 (620.0x2)x3

290.0 + 340.0x2 290.0 + 340.0x2 340.0x3

4,833.3 + 5,666.7x2 4,833.3 + 5,666.7x2 5,666.7x3

8.00 8.00 8.0078.40 78.40 78.4022.22 22.22 22.227/8" 7/8" 7/8"

53.98 53.98 53.982 1/8" 2 1/8" 2 1/8"

- - -- - -

200 (220) 200 (220) 200 (220)

110 (40) 110 (40) 110 (40)

- - -0.75 ~ 1.50 0.75 ~ 1.50 0.75 ~ 1.50

R410A R410A R410A36.40 36.40 40.50

- - -- - -

285.0 + 342.0 + 350.0 285.0 + 350.0x2 333.0 + 350.0x2

305.0 + 364.0 + 372.0 305.0 + 372.0x2 355.0 + 372.0x2

1,295x1,695x765 +(1,295x1,795x765)x2

1,295x1,695x765 +(1,295x1,795x765)x2 (1,295x1,795x765)x3

1,363x1,887x832 +(1,363x1,987x832)x2

1,363x1,887x832 +(1,363x1,987x832)x2 (1,363x1,987x832)x3

-5.0 ~ 48.0 -5.0 ~ 48.0 -5.0 ~ 48.0-25.0 ~ 24.0 -25.0 ~ 24.0 -25.0 ~ 24.0

* Specifications may be subject to change without prior notice.1) Nominal cooling capacities are based on;- Indoor temperature : 27°C DB, 19°C WB- Outdoor temperature : 35°C DB, 24°C WB, Equivalent refrigerant piping : 7.5m, Level differences : 0m2) Nominal heating capacities are based on;- Indoor temperature : 20°C DB, 15°C WB- Outdoor temperature : 7°C DB, 6°C WB, Equivalent refrigerant piping : 7.5m, Level differences : 0m3) Sound pressure was acquired in an anechoic room. Thus actual noise level may be different depending on the installation conditions.4) If outdoor unit is located in a higher position than indoor unit, level difference is 110m or under.(If the level difference is higher than 50m, make a decision by PDM kit installation Guide software whether the PDM kit should be installed or not.)*PDM kit: Pressure Drop Modulation kit

2

Page 18: Tdb vrf dvm s standard for turkey (odu 50 hz hp) ver.1.0

Specifications

OutdoorTypeModel NamePower Supply Ø, #, V, HzMode -

Performance

HP HP

Capacity(Nominal)

CoolingkW

Btu/h

HeatingkW

Btu/h

Power

Power Input(Nominal)

Cooling 1) kWHeating 2) kW

CurrentInput(Nominal)

Cooling 1) AHeating 2) A

MCA AMFA A

COP

EER (Nominal Cooling) -COP (Nominal Heating) -

Energy Grade--

Compressor

Type -

Output kW x n

Model Name -

Oil Type -

Fan

Type -

Output x n W

Air Flow RateCMM

l/s

ExternalStatic Max.

mmAQPa

PipingConnections

Liquid PipeØ, mmØ, inch

Gas PipeØ, mmØ, inch

Discharge Gas PipeØ, mmØ, inch

InstallationLimitation

Max. Length m

Max. Height m

Field WiringPower Source Wire mm²Transmission Cable mm²

RefrigerantType -Factory Charging kg

SoundPressure

dBAPower

ExternalDimension

New Weight kg

Shipping Weight kg

Net Dimensions (WxHxD) mm

Shipping Dimensions(WxHxD) mm

OperatingTemp.

Cooling ºCHeating ºC

DVM S(NEW) DVM S(NEW) DVM S(NEW)AM860KXVAGH/TK AM880KXVAGH/TK AM900KXVAGH/TK

3,4,380-415,50 3,4,380-415,50 3,4,380-415,50HP HP HP

86.00 88.00 90.00240.80 246.60 252.00

821,600 841,400 859,900270.90 277.20 283.50

924,300 945,800 967,30064.31 66.09 68.1159.18 61.36 61.76

103.10 106.00 109.2094.90 98.40 99.00

206.00 213.00 219.00250.00 250.00 250.00

3.74 3.73 3.704.58 4.52 4.59

- - -- - -

SSC Scroll x 6 SSC Scroll x 6 SSC Scroll x 6

(6.39x2) + (7.81x2)x2 (6.76x2) + (7.81x2)x2 (7.81x2)x3

DS-GB066FAVBx2 +DS4GJ5080FVAx4

DS-GB070FAVAx2 +DS4GJ5080FVAx4 DS4GJ5080FVAx6

PVE PVE PVEPropeller Propeller Propeller

(620.0x2)x3 (620.0x2)x3 (620.0x2)x3

340.0x3 340.0x3 340.0x3

5,666.7x3 5,666.7x3 5,666.7x3

8.00 8.00 8.0078.40 78.40 78.4022.22 22.22 22.227/8" 7/8" 7/8"

53.98 53.98 53.982 1/8" 2 1/8" 2 1/8"

- - -- - -

200 (220) 200 (220) 200 (220)

110 (40) 110 (40) 110 (40)

- - -0.75 ~ 1.50 0.75 ~ 1.50 0.75 ~ 1.50

R410A R410A R410A40.50 42.00 42.00

- - -- - -

333.0 + 350.0x2 342.0 + 350.0x2 350.0x3

355.0 + 372.0x2 364.0 + 372.0x2 372.0x3

(1,295x1,795x765)x3 (1,295x1,795x765)x3 (1,295x1,795x765)x3

(1,363x1,987x832)x3 (1,363x1,987x832)x3 (1,363x1,987x832)x3

-5.0 ~ 48.0 -5.0 ~ 48.0 -5.0 ~ 48.0-25.0 ~ 24.0 -25.0 ~ 24.0 -25.0 ~ 24.0

* Specifications may be subject to change without prior notice.1) Nominal cooling capacities are based on;- Indoor temperature : 27°C DB, 19°C WB- Outdoor temperature : 35°C DB, 24°C WB, Equivalent refrigerant piping : 7.5m, Level differences : 0m2) Nominal heating capacities are based on;- Indoor temperature : 20°C DB, 15°C WB- Outdoor temperature : 7°C DB, 6°C WB, Equivalent refrigerant piping : 7.5m, Level differences : 0m3) Sound pressure was acquired in an anechoic room. Thus actual noise level may be different depending on the installation conditions.4) If outdoor unit is located in a higher position than indoor unit, level difference is 110m or under.(If the level difference is higher than 50m, make a decision by PDM kit installation Guide software whether the PDM kit should be installed or not.)*PDM kit: Pressure Drop Modulation kit

2

Page 19: Tdb vrf dvm s standard for turkey (odu 50 hz hp) ver.1.0

Operation limitO

utd

oor

tem

pera

ture

(℃

DB

)

10 14 20 25 27 30

50

40

30

20

10

-10

-20

-5

-15

-30

0

ContinuousOperation Range

“Expand operational temperature range” Option

Indoor temperature(℃ WB)

Outd

oor

tem

pera

ture

(℃

WB

)

Indoor temperature(℃ DB)

10 15 20 25 27 30

30

2024

10

-10

-20

-30

0Continuous

Operation Range

WarmingUp

OperationRange

Cooling Heating

Defrosting correction factor

On heating operation, frost can be formed on heat exchanger according to outdoor temperature.(Frost on heat exchanger results in decreasing the performance.)To remove frost on heat exchanger of outdoor unit, defrost operation is carried out periodically.During defrost operation, capacity of outdoor unit may decrease.The decrement is not considered to the individual capacity tables.

3

Page 20: Tdb vrf dvm s standard for turkey (odu 50 hz hp) ver.1.0

Dimensional drawingOutdoorAM140KXVAGH/TK, AM160KXVAGH/TK, AM180KXVAGH/TK, AM200KXVAGH/TK, AM220KXVAGH/TK

Units : mm / inches

Table of descriptions1 Gas Ref. pipe 7 Knock-out Hole for Ref. Piping

2 Liquid Ref. pipe 8 Anchor Bolt Hole

3 Power wiring conduit 9

4 Communication wiring conduit 10

5 Power wiring conduit 11

6 Communication wiring conduit 12

1295[4'-3"]

765

[2'-6

"]

616

[2'-0

1/4

"]

671

[2'-2

1/2

"]24

1 [9

1/2

"]

122 [4 3/4"]

51 [2"]

1695

[5'-6

3/4

"]

36 [1 1/2"]

557

[1'-1

0"]

492

[1'-7

1/2

"]17

2 [6

3/4

"]

107 [4 1/4"]

575[1'-10 3/4"]

761

[2'-6

"]

1295 [4'-3"]

803

[2'-7

3/4

"]

① ② ③④

4

Page 21: Tdb vrf dvm s standard for turkey (odu 50 hz hp) ver.1.0

Dimensional drawingOutdoorAM240KXVAGH/TK, AM260KXVAGH/TK, AM280KXVAGH/TK, AM300KXVAGH/TK

4

Page 22: Tdb vrf dvm s standard for turkey (odu 50 hz hp) ver.1.0

Electrical wiring diagramOutdoorAM140KXVAGH/TK, AM200KXVAGH/TK, AM220KXVAGH/TK

5

Page 23: Tdb vrf dvm s standard for turkey (odu 50 hz hp) ver.1.0

Electrical wiring diagramOutdoorAM160KXVAGH/TK, AM180KXVAGH/TK, AM240KXVAGH/TK, AM260KXVAGH/TK, AM280KXVAGH/TK, AM300KXVAGH/TK

5

Page 24: Tdb vrf dvm s standard for turkey (odu 50 hz hp) ver.1.0

Sound pressure levelOutdoor

Note

* Specifications may be subject to change without prior notice

1) These operation values were obtained in an anechoic room.

2) Sound pressure level will vary depending on a range of factors such as the construction of the particular room

3) Operation sound level may differ depending on operation and ambient conditions.

NC curve

Unit: dB(A)

Model Cooling

AM140KXVAGH/TK 61

AM160KXVAGH/TK 63

AM180KXVAGH/TK 64

AM200KXVAGH/TK 65

NC 65

NC 60

NC 55

NC 50

NC 45

NC 40

NC 35

NC 30

NC 25

NC 20

NC 15

Cooling

63 125 250 500 1000 2000 4000 8000

Octave band center frequency(Hz)

10

20

30

40

50

60

70

80

Sou

nd p

ress

ure

leve

l(dB

)

1) AM140KXVAGH/TK

NC 65

NC 60

NC 55

NC 50

NC 45

NC 40

NC 35

NC 30

NC 25

NC 20

NC 15

Cooling

63 125 250 500 1000 2000 4000 8000

Octave band center frequency(Hz)

10

20

30

40

50

60

70

80

Sou

nd p

ress

ure

leve

l(dB

)

2) AM160KXVAGH/TK

NC 65

NC 60

NC 55

NC 50

NC 45

NC 40

NC 35

NC 30

NC 25

NC 20

NC 15

Cooling

63 125 250 500 1000 2000 4000 8000

Octave band center frequency(Hz)

10

20

30

40

50

60

70

80

Sou

nd p

ress

ure

leve

l(dB

)

3) AM180KXVAGH/TK

NC 65

NC 60

NC 55

NC 50

NC 45

NC 40

NC 35

NC 30

NC 25

NC 20

NC 15

Cooling

63 125 250 500 1000 2000 4000 8000

Octave band center frequency(Hz)

10

20

30

40

50

60

70

80

Sou

nd p

ress

ure

leve

l(dB

)

4) AM200KXVAGH/TK

6

Page 25: Tdb vrf dvm s standard for turkey (odu 50 hz hp) ver.1.0

Sound pressure levelOutdoor

Note

* Specifications may be subject to change without prior notice

1) These operation values were obtained in an anechoic room.

2) Sound pressure level will vary depending on a range of factors such as the construction of the particular room

3) Operation sound level may differ depending on operation and ambient conditions.

NC curve

Unit: dB(A)

Model Cooling

AM220KXVAGH/TK 65

AM240KXVAGH/TK 66

AM260KXVAGH/TK 66

AM280KXVAGH/TK 69

NC 65

NC 60

NC 55

NC 50

NC 45

NC 40

NC 35

NC 30

NC 25

NC 20

NC 15

Cooling

63 125 250 500 1000 2000 4000 8000

Octave band center frequency(Hz)

10

20

30

40

50

60

70

80

Sou

nd p

ress

ure

leve

l(dB

)

1) AM220KXVAGH/TK

NC 65

NC 60

NC 55

NC 50

NC 45

NC 40

NC 35

NC 30

NC 25

NC 20

NC 15

Cooling

63 125 250 500 1000 2000 4000 8000

Octave band center frequency(Hz)

10

20

30

40

50

60

70

80

Sou

nd p

ress

ure

leve

l(dB

)

2) AM240KXVAGH/TK

NC 65

NC 60

NC 55

NC 50

NC 45

NC 40

NC 35

NC 30

NC 25

NC 20

NC 15

Cooling

63 125 250 500 1000 2000 4000 8000

Octave band center frequency(Hz)

10

20

30

40

50

60

70

80

Sou

nd p

ress

ure

leve

l(dB

)

3) AM260KXVAGH/TK

NC 65

NC 60

NC 55

NC 50

NC 45

NC 40

NC 35

NC 30

NC 25

NC 20

NC 15

Cooling

63 125 250 500 1000 2000 4000 8000

Octave band center frequency(Hz)

10

20

30

40

50

60

70

80

Sou

nd p

ress

ure

leve

l(dB

)

4) AM280KXVAGH/TK

6

Page 26: Tdb vrf dvm s standard for turkey (odu 50 hz hp) ver.1.0

Sound pressure levelOutdoor

Note

* Specifications may be subject to change without prior notice

1) These operation values were obtained in an anechoic room.

2) Sound pressure level will vary depending on a range of factors such as the construction of the particular room

3) Operation sound level may differ depending on operation and ambient conditions.

NC curve

Unit: dB(A)

Model Cooling

AM300KXVAGH/TK 69

NC 65

NC 60

NC 55

NC 50

NC 45

NC 40

NC 35

NC 30

NC 25

NC 20

NC 15

Cooling

63 125 250 500 1000 2000 4000 8000

Octave band center frequency(Hz)

10

20

30

40

50

60

70

80

Sou

nd p

ress

ure

leve

l(dB

)

1) AM300KXVAGH/TK

6

Page 27: Tdb vrf dvm s standard for turkey (odu 50 hz hp) ver.1.0

Sound power levelOutdoor

Note

125 250 500 1000 2000 4000 8000 A

Octave band center frequency(Hz)

0

10

20

30

40

50

60

70

80

90

100

Sou

nd p

ower

leve

l(dB

)

1)AM140KXVAGH/TK

125 250 500 1000 2000 4000 8000 A

Octave band center frequency(Hz)

0

10

20

30

40

50

60

70

80

90

100

Sou

nd p

ower

leve

l(dB

)

2)AM160KXVAGH/TK

125 250 500 1000 2000 4000 8000 A

Octave band center frequency(Hz)

0

10

20

30

40

50

60

70

80

90

100

Sou

nd p

ower

leve

l(dB

)

3)AM180KXVAGH/TK

125 250 500 1000 2000 4000 8000 A

Octave band center frequency(Hz)

0

10

20

30

40

50

60

70

80

90

100

Sou

nd p

ower

leve

l(dB

)

4)AM200KXVAGH/TK

Unit: dB(A)

Model Power

AM140KXVAGH/TK 81

AM160KXVAGH/TK 83

AM180KXVAGH/TK 84

AM200KXVAGH/TK 87

* Specifications may be subject to change1) dBA = A-weighted sound power level.2) Reference power : 1pW.3) Measured according to ISO 3741.

7

Page 28: Tdb vrf dvm s standard for turkey (odu 50 hz hp) ver.1.0

Sound power levelOutdoor

Note

125 250 500 1000 2000 4000 8000 A

Octave band center frequency(Hz)

0

10

20

30

40

50

60

70

80

90

100

Sou

nd p

ower

leve

l(dB

)

1)AM220KXVAGH/TK

125 250 500 1000 2000 4000 8000 A

Octave band center frequency(Hz)

0

10

20

30

40

50

60

70

80

90

100

Sou

nd p

ower

leve

l(dB

)

2)AM240KXVAGH/TK

125 250 500 1000 2000 4000 8000 A

Octave band center frequency(Hz)

0

10

20

30

40

50

60

70

80

90

100

Sou

nd p

ower

leve

l(dB

)

3)AM260KXVAGH/TK

125 250 500 1000 2000 4000 8000 A

Octave band center frequency(Hz)

0

10

20

30

40

50

60

70

80

90

100

Sou

nd p

ower

leve

l(dB

)

4)AM280KXVAGH/TK

Unit: dB(A)

Model Power

AM220KXVAGH/TK 89

AM240KXVAGH/TK 89

AM260KXVAGH/TK 89

AM280KXVAGH/TK 90

* Specifications may be subject to change1) dBA = A-weighted sound power level.2) Reference power : 1pW.3) Measured according to ISO 3741.

7

Page 29: Tdb vrf dvm s standard for turkey (odu 50 hz hp) ver.1.0

Sound power levelOutdoor

Note

125 250 500 1000 2000 4000 8000 A

Octave band center frequency(Hz)

0

10

20

30

40

50

60

70

80

90

100

Sou

nd p

ower

leve

l(dB

)

1)AM300KXVAGH/TK

Unit: dB(A)

Model Power

AM300KXVAGH/TK 90* Specifications may be subject to change1) dBA = A-weighted sound power level.2) Reference power : 1pW.3) Measured according to ISO 3741.

7

Page 30: Tdb vrf dvm s standard for turkey (odu 50 hz hp) ver.1.0

Cycle diagramOutdoorAM140KXVAGH/TK, AM160KXVAGH/TK, AM180KXVAGH/TK

Abbreviation Explanation Abbreviation ExplanationINV Inveter Compressor V_AR Accumulator Oil Return ValveOFM Outdoor Fan Motor CV_E EEV Bypass Check ValveOHX Outdoor Heat Exchanger CV_D Discharge Check ValveAC Accumulator T_D Discharge Temp. SensorOS Oil Separator T_S Suction Temp. SensorIC Intercooler T_CO Cond Out Temp. Sensor

IPMC IPM Cooler T_EI EVI In Temp. SensorHPS High Pressure Sensor T_EO EVI Out Temp. SensorLPS Low Pressure Sensor T_L Liquid Tube Temp. Sensor

HPSW High Pressure Switch T_CT Comp. Top Temp. SensorE_M Main EEV T_A Ambient Temp. SensorE_EV EVI EEV SV_G Gas Pipe Service ValveV_ES EVI Sol. Valve SV_L Liquid Pipe Service ValveV_EB EVI Bypass ValveV_HG Hot Gas Bypass ValveV_4W 4Way Valve

s

E

s

E

s

INV

OFM

OHX

AC

OS

IC

HPS

HPSW

E_M

E_EV

V_EB

V_HG

V_4W

V_AR

CV_E

CV_D

T_D

T_CO

T_EI

T_EO

T_L

T_CT

T_A

V_ES

SV_G

SV_L

IPMC

LPS

T_S

8

Page 31: Tdb vrf dvm s standard for turkey (odu 50 hz hp) ver.1.0

Cycle diagramOutdoorAM200KXVAGH/TK, AM220KXVAGH/TK

Abbreviation Explanation Abbreviation ExplanationINV1 Inveter Compressor V_4W 4Way ValveINV2 Inveter Compressor V_AR Accumulator Oil Return ValveOFM Outdoor Fan Motor CV_E EEV Bypass Check ValveOHX Outdoor Heat Exchanger CV_D Discharge Check ValveAC Accumulator T_D Discharge Temp. SensorOS Oil Separator T_S Suction Temp. SensorIC Intercooler T_CO Cond Out Temp. Sensor

IPMC IPM Cooler T_EI EVI In Temp. SensorHPS High Pressure Sensor T_EO EVI Out Temp. SensorLPS Low Pressure Sensor T_L Liquid Tube Temp. Sensor

HPSW High Pressure Switch T_CT Comp. Top Temp. SensorE_M Main EEV T_A Ambient Temp. SensorE_EV EVI EEV SV_G Gas Pipe Service ValveV_ES EVI Sol. Valve SV_L Liquid Pipe Service ValveV_EB EVI Bypass ValveV_HG Hot Gas Bypass Valve

E

s

E

s

INV

OFM

OHX

AC

OS IC

HPS

HPSW

E_M

E_EV

V_ES

V_EB

V_HG

V_4W

CV_E

CV_D

T_D

T_CO

T_EI

T_EO

T_L

T_CT

T_A

INV

V_ES

CV_D

T_D

T_CT

OSHPSW

SV_G

SV_L

IPMC IPMC

s V_AR1

LPS

T_S

8

Page 32: Tdb vrf dvm s standard for turkey (odu 50 hz hp) ver.1.0

Cycle diagramOutdoorAM240KXVAGH/TK, AM260KXVAGH/TK

Abbreviation Explanation Abbreviation ExplanationINV1 Inveter Compressor V_4W 4Way ValveINV2 Inveter Compressor V_AR Accumulator Oil Return ValveOFM Outdoor Fan Motor CV_E EEV Bypass Check ValveOHX Outdoor Heat Exchanger CV_D Discharge Check ValveAC Accumulator T_D Discharge Temp. SensorOS Oil Separator T_S Suction Temp. SensorIC Intercooler T_CO Cond Out Temp. Sensor

IPMC IPM Cooler T_EI EVI In Temp. SensorHPS High Pressure Sensor T_EO EVI Out Temp. SensorLPS Low Pressure Sensor T_L Liquid Tube Temp. Sensor

HPSW High Pressure Switch T_CT Comp. Top Temp. SensorE_M Main EEV T_A Ambient Temp. SensorE_EV EVI EEV SV_G Gas Pipe Service ValveV_ES EVI Sol. Valve SV_L Liquid Pipe Service ValveV_EB EVI Bypass ValveV_HG Hot Gas Bypass Valve

s

E

s

INV1

OFM

OHX

AC

IC

HPS

HPSW1E_EV

V_ES

V_EB

V_HG

V_4W

T_D1

T_S

T_EI

T_EO

T_L

T_CT1

T_A

V_ES

T_D2T_CT2

HPSW2

SV_G

SV_L

IPMC1 IPMC2

E_M1

E_M2

LPS

V_AR1

CVD1 CVD2

CV_E1

T_CO

s

T_CIE

E

CV_E2

OS2OS1

INV2

8

Page 33: Tdb vrf dvm s standard for turkey (odu 50 hz hp) ver.1.0

Cycle diagramOutdoorAM280KXVAGH/TK, AM300KXVAGH/TK

Abbreviation Explanation Abbreviation ExplanationINV1 Inveter Compressor V_4W 4Way ValveINV2 Inveter Compressor V_AR Accumulator Oil Return ValveOFM Outdoor Fan Motor CV_E EEV Bypass Check ValveOHX Outdoor Heat Exchanger CV_D Discharge Check ValveAC Accumulator T_D Discharge Temp. SensorOS Oil Separator T_S Suction Temp. SensorIC Intercooler T_CO Cond Out Temp. Sensor

IPMC IPM Cooler T_EI EVI In Temp. SensorHPS High Pressure Sensor T_EO EVI Out Temp. SensorLPS Low Pressure Sensor T_L Liquid Tube Temp. Sensor

HPSW High Pressure Switch T_CT Comp. Top Temp. SensorE_M Main EEV T_A Ambient Temp. SensorE_EV EVI EEV SV_G Gas Pipe Service ValveV_ES EVI Sol. Valve SV_L Liquid Pipe Service ValveV_EB EVI Bypass ValveV_HG Hot Gas Bypass Valve

RE3.0L

s

E

s

INV1

OFM

OHX

AC

IC

HPS

HPSW1E_EV

V_ES

V_EB

V_HG

V_4W

T_D1

T_S

T_EI

T_EO

T_L

T_CT1

T_A

V_ES

T_D2T_CT2

HPSW2

SV_G

SV_L

IPMC1 IPMC2

E_M1

E_M2

LPS

V_AR1

CVD1 CVD2

CV_E1

T_CO

s

T_CIE

E

CV_E2

OS2OS1

INV2

8

Page 34: Tdb vrf dvm s standard for turkey (odu 50 hz hp) ver.1.0

2016.01Ver.1.0