Content
• The Company, Experience & Technology
• System and Operational Aspects
• Anaerobic Digester & BNR Enhancement
• Agricultural Applications
• Summary
Lystek - The Company
• Utilizing biosolids & other organics resources by processing through on- and off-site solutions:
- Producing Enhanced treated / Class A EQ product
- Improving WWTP processes utilizing Lystek’s hydrolyzed product
• Developed at University of Waterloo, Canada in year 2000
• Experienced management team in the organic waste management, wastewater industry, agriculture and marketing
• Ownership: Management & RW Tomlinson, Ottawa (>1000 employees, billion dollar (+) corp. = financial strength & backing)
Who Uses Lystek Now?
Location Guelph St. Marys
Southgate Iroquois Elora North Battleford
Status 2008 2010
2012
2012
2014
2014 Fall
Capacity (WT/Y)
18,000 3,500 150,000 20,000 3,500 3,500
Location On site On site Off site Off site On site On site
Ownership Guelph St Marys Lystek DES/Third High Farms
Centre Wellington
North Battleford
Solution Design Build License
Design Tech License
Design Build Own Operate
Design Build License
Design Build License
Design Build License Product Market
Serving Cities of Toronto, Ottawa, Peterborough, Oakville, Burlington, and Regions of Waterloo and Halton…and several other communities.
Lystek Technology – Overview • Low Temperature Physical Chemical Hydrolysis Technology
- A back-end solution, installed after dewatering
• Produces a multi-purpose, hydrolysed product for:
- Anaerobic Digester Enhancement
• Improve biogas yields by >30%
• Reduce biosolids volumes by >20%
- BNR System Enhancement – a cost effective, alternative carbon source
- Liquid biofertilizer – CFIA registered (Canada) / Enhanced treated (UK)/ Class A EQ (USA) – high organic matter & NPK – interest and demand from farm sector is exceptionally high
Technical/Scientific Basis
• Cell disintegration & hydrolysis of complex organic molecules into simpler compounds
• Process makes the residual recalcitrant volatile solids in digested
biosolids more amenable to further biodegradation when re-fed to anaerobic digester = “LysteMize”
• Hydrolyzed product provides readily available organics for AD and BNR
system + nutrients for soil/plants
• Product contains >40% of the TCOD as SCOD
• Product contains 10-fold higher VFA as compared to standard, biosolids cake
Lystek vs. Typical Thermal Hydrolysis Items Typical Thermal Hydrolysis Lystek Hyrdrolysis
Technology High temperature, high pressure hydrolysis
Low temperature, high shear, physical-chemical hydrolysis
Process condition
160-170oC for 20 - 60 min @ 100 - 130 psi, multiple steps
70-75oC, 45 min, pH 9.5–10.0, high shear, atm. Press., one step
Heat source High pressure steam boiler Low pressure steam boiler or CHP
Installation Prior to anaerobic digestion, interferes with existing WWTP processes
After anaerobic digestion and dewatering, no interference with existing WWTP processes
Side stream / residues
High N centrate from first stage dewatering - extensive treatment
None
Dewatering Two stage: pre- and post-AD One stage conventional after AD
Footprint Large Small
Capital cost High Low
Lystek Process - Simple PFD
SOLID
FEEDSTOCK
HOPPER
BRIDGE
Nothing wasted .. Everything to gain. _______ _
DEWATERED
BIOSOLIDS
-I PROGRESSIVE
CAVI"TY PUMP
HIGH SPEED
MIXER
MIXING
TANK
PRODUCT
PUMP
ALKALI
.-----------I+,
STORAGE 7
ALKALI
STORAGE
TANK
LysteGroTM Product
• Homogeneous liquid/ high solid (15-19%) product
• Viscosity <5,000 cP • Fully pumpable using
conventional liquid equipment
• Enhanced treated,
pathogen-free / Class A EQ • Nutrient rich (NPK 4:3:2) • Long-term storage stability • No pathogen regrowth • Huge demand from the
agricultural sector
On-Site Facility (Post Dewatering)
25,000 WT facility/ 95 sq. m. (1000 sq. ft.)
Nothing wasted .. Everything to gain. - ------------------,'
Regional Facility (Off-Site)
Southgate, Ontario - 150,000 WT/year
Nothing wasted .. Everything to gain. - ------------------,'
Operations
• Small footprint
- 95 sq. m. (1000 sq. ft.) - 25,000 WT / 230 sq. m. (2500 sq. ft.) - 100,000 WT
• Installation:
- Simple equipment, quick installation, modular system
- No high temperature / pressure vessels required
• Operations
- Simple, fully automated SCADA control
- Low maintenance
• Labour
- Minimum operator attention,
- <2 man hours per day
Operational Parameters
• Power input (pumps/mixer)
- 52-58 KWH per dry ton
- High speed shear
• KOH/NaOH input (45-50% solution)
- 80-90 kg (175-195 lbs)/dry ton to pH 9.5-10.0
• Temperature
• 70-75oC / 158-167oF / 30 min / Class A regime
• Natural gas
- Low pressure steam boiler or CHP heat source
- 13-15m3 natural gas per dry ton
Strict Odour Control
• Totally enclosed facility – feedstock material receiving and processing area, enclosed reactors, air handling and odor abatement train
• Storage: enclosed storage tanks, covered lagoons
• The product: stable, homogeneous, reduced odor, no pathogen regrowth, limited exposure to air
• Transport: enclosed tanker vehicles
• Land application: sub-surface injection
Performance Indicators
• Biosolids feedstock input
- Anaerobically or aerobically digested biosolids
- Undigested sludge & source separated organics
- Solids 1% to 35% @ 15-19% solids level in the reactor
• Re-feeding hydrolysed product into anaerobic digesters - Up to 50% of the product can be re-fed into digesters - >30% more biogas yield potential - >20% additional VS breakdown after re-feeding
• Re-feeding hydrolysed product into BNR - Up to 30% of the product can be re-fed into BNR - Replaces commercial methanol or glycerol
Greenhouse Gas Reduction Potential
Biosolids management scenarios GHG Estimate (Mg CO2 eq. / 100 DT AD biosolids eq.)
Landfill 297 to 335
Incineration - 23 to 224
Heat drying 51 to 71
Compost 6 to 34
Land application (Class B cake) - 40
Lystek AD biosolids to land - 49
Lystek, 30% recycle to AD, electricity production, rest to land
- 47
Lystek, 30% recycle to AD, heat production, rest to land
- 63
BEAM Model 1.1
LysteMize - Digester & BNR Optimization
Sewage
Nothing wasted.
HEADWORKS
lyslek Recyde loBNA
lystek 8iosolids for Beneficial Reuse on Agricultural
Land
Everything to gain. _______ _
tnlemal Recirculation
Retum Activated Sludge
Dn.m Thickener
SECONDARY CLARIFIERS
Dlgesl'" S~lanl
CENTRIFUGE SECONDARY
DIGESTER
lystek Recycle to Pnmasy Digester
PRIMARY DIGESTER
UV DISINFECTION
Waste Activated
ROTARY DRUM
THICKENER
Final E1fIuent
Digester and BNR System Enhancement
• Improved biogas yields in Anaerobic digester
- Independent lab studies at Canadian and the US Universities and onsite pilot tests have shown potential of re-feeding Lystek biosolids to anaerobic digester
- Lystek processed biosolids are 50-60% further biodegradable
- 30-50% more biogas potential with Lystek product
• Carbon source Enhanced BNR system
- Independent lab studied have indicated potential of Lystek biosolids as carbon source in BNR system
- Lystek biosolids shows equal or higher specific denitrification rates (SDNR) (mg NOx-N/mg VSS) compared to conventional glycerol, methanol or acetic acid
Value of the LysteGroTM Fertilizer
• Balanced agricultural nutrient source, fertilizer value
$90- $100/1000 gal
• N-P2O5-K2O = 30-35-30 lbs/1000 gal, in the year of
application
• S 15 lbs/1000 gal, Ca 45 lbs/1000 gal and other micronutrients such as Cu, Zn, B, Mg etc.
• Application rates = 3000 – 4000 gal/acre
• Organic matter = ~5%
LysteGro vs. Chemical Fertilizer Trial
With LysteGro - ear leaf strong color
With Chemical Fertilizer – ear leaf firing
LysteGro vs. Chemical Fertilizer Trial
Tassel stage - leaves yellowing due to lack of available N & K
Tassel stage - strong leaf color - critical stage of development
One System = Multiple Benefits
Produce a Class A EQ Fertilizer Product
Optimize Digesters & BNR systems
Advanced Technology & Benefits • Lystek System
- Low capital cost - Small foot print - modular system – easy to expand
- Minimum operator attention – Fully automated / SCADA
- Simple to operate, easy to maintain – standard equipment, low pressure steam, no heat exchangers
- No side centrate or waste stream for further treatment
- Flexible, back-end solution (after dewatering) - no interferences
- Can be paired with (other), existing, pre-treatment processes
- Multi-use end product
• Strong R&D program
- Academic and industrial collaborations for continuous process and product improvement
Thank You
Nothing wasted. Everything to gain.
t: 226-444-0186 e: [email protected] w: www.lystek.com s: