31
Yokogawa Cell Voyager 7000 Wako Automation Introduction and Overview

High content imaging with the yokogawa cv7000 system

Embed Size (px)

Citation preview

Page 1: High content imaging with the yokogawa cv7000 system

Yokogawa Cell Voyager 7000

Wako Automation Introduction and Overview

Page 2: High content imaging with the yokogawa cv7000 system

Wako Automation

Background

Page 3: High content imaging with the yokogawa cv7000 system

Wako Pure Chemicals Japan, USA, Germany

!

Wako Diagnostics Japan, USA, Germany

!

Wako Automation USA

Page 4: High content imaging with the yokogawa cv7000 system

High Content Imaging Platform

Yokogawa CV7000

Page 5: High content imaging with the yokogawa cv7000 system

High Content Imaging Platform

Automation-Ready

Page 6: High content imaging with the yokogawa cv7000 system

Yokogawa CSU-W1

•Minimum Bleaching and Toxicity •Reduced Crosstalk •Visualize Dynamic Events in Live Cells

Dual Spinning Disk Systems

Page 7: High content imaging with the yokogawa cv7000 system

4X Cells Imaged Reduced Crosstalk Thicker Samples

CSU-W1- Wide View Dual Spinning Disk

Page 8: High content imaging with the yokogawa cv7000 system

Live Cell Imaging

HeLa cell with Azami green, GFP, 10X, 10% 488nm laser 3 days

Page 9: High content imaging with the yokogawa cv7000 system

Yokogawa CSU-X1 Dual Spinning Disk

Live Cell Imaging

Live Cells imaged every 20 minutes for 24 hours

Page 10: High content imaging with the yokogawa cv7000 system

Cell Voyager 7000 Configuration

Page 11: High content imaging with the yokogawa cv7000 system

Simultaneous Imaging with Three (3) Cameras

sCMOS -20˚C 5.5MP, 2560 x 2160 6.5µm pixel

Page 12: High content imaging with the yokogawa cv7000 system

Objective Choices

Page 13: High content imaging with the yokogawa cv7000 system

Choose Up To 6 Lenses Dry: 2x, 4x NA .16, 10x NA .4, 20x NA .75,

40x NA .95, 20x NA .45 LWD !

Water Immersion: 40x NA 1.15, 60x NA 1.2

Phase Contrast: 10X, 20X

Page 14: High content imaging with the yokogawa cv7000 system

Lens Field of View 2x 8.3 mm x7mm 4x 4.15 mm x 3.5 mm 10x 1.66 mm x1.4 mm 20x 0.83 mm x0.7 mm 40x 0.415 mm x0.35 mm 60x 0.276 mm x0.23 mm

sCMOS Camera FOV

Page 15: High content imaging with the yokogawa cv7000 system

Plate TypeWell Size Lens

96 well 6.5mm 2x objective

384 well 3.25mm 4x objective

1536 well 1.5mm 10x objective

sCMOS Camera FOV

Page 16: High content imaging with the yokogawa cv7000 system

HeLa cell mitochondria stained with MitoTracker® Red CMXRos 0.2 um steps, 21 slices, 60X water immersion lens.

Page 17: High content imaging with the yokogawa cv7000 system

Live Cell Imaging

!40X lens, Laser; 561 nm, Laser power; 10%, Exposure time; 20ms, 3 days, 20 min.

Neural Progenitor Cells

Page 18: High content imaging with the yokogawa cv7000 system

Reproducibility of stage Plate removed 6X

Imaged with 60x Water

Page 19: High content imaging with the yokogawa cv7000 system

Imaging Modes

Confocal Epifluorescence Phase Contrast Bright Field

Page 20: High content imaging with the yokogawa cv7000 system

Lasers: Choice of Four

405, 488, 532, 561, 640 !

UV LED: 365 (not confocal)

Halogen Lamp (not confocal)

Page 21: High content imaging with the yokogawa cv7000 system

Neurite Imaging60X W lens, NA 1.2

Page 22: High content imaging with the yokogawa cv7000 system

CV7000 Capabilities

Page 23: High content imaging with the yokogawa cv7000 system

6 to 1536 well plates Microscope Slides

!

Incubated Stage 35˚C - 40˚C, CO2, Humidity

Live Cell Imaging !

Laser Based Autofocus Image Based Autofocus

!

Dispense Option single channel

for kinetics assays

Page 24: High content imaging with the yokogawa cv7000 system

Image Standard Plate Types & Microscope Slides

Page 25: High content imaging with the yokogawa cv7000 system

!

!

!

3 colors, 96 wells, <2 min3 colors, 384 wells, <5 min3 colors, 1536 wells, <18 min

(50ms, 1 field, 1 z Stack)

Imaging Speed (3 cameras)

Exceptional Image Quality

Page 26: High content imaging with the yokogawa cv7000 system

Additional Features

Page 27: High content imaging with the yokogawa cv7000 system

Thick Sample Imaging Possible

with CSU-W1

Page 28: High content imaging with the yokogawa cv7000 system

Cy2 Collagen IV (Basement membrane) - green CY3 Pgp9.5 (pan-neuronal Marker)- red

DAPI DNA (Cell nucleuc)- Blue

Exp: 200ms, Z axis 80um , 1.0µm spacing, 81 slices in total  Objective: 60X

Page 29: High content imaging with the yokogawa cv7000 system

The CV7000 Benefits

Page 30: High content imaging with the yokogawa cv7000 system

Laser  light  focused  through  microlens  Reduced  photo-­‐bleaching  and  photo-­‐toxicity  

Be:er  confocal  images

Yokogawa Dual Spinning Disk System

Page 31: High content imaging with the yokogawa cv7000 system

unmatched speed

4x field of view

live cell imaging for days