49
IMMEDIATE PLACEMENT IMMEDIATE LOAD # 7 Guide Right™ Bone Graft 2-Piece Offset Guide Posts I nvi vo5 Software Triad® gel Application Sequence Bending Tool HLM 2016

Immediate placement immediate load #7 hlm

Embed Size (px)

Citation preview

Page 1: Immediate placement   immediate load  #7 hlm

IMMEDIATE PLACEMENT ▪ IMMEDIATE LOAD# 7

Guide Right™

Bone Graft2-Piece Offset Guide Posts

Invivo5 SoftwareTriad® gel Application Sequence

Bending Tool

HLM 2016

Page 2: Immediate placement   immediate load  #7 hlm

Guide Right™ Surgical Guide System

Start With Precision. Place With Confidence.™

1.800.314.0065 • www.deplaque.com

fabricate ▪ evaluate ▪ correct ▪ verify ▪ place

DéPlaque

Guide Right™ Surgical Guide Systemfabricate ▪ evaluate ▪ correct ▪ re-fabricate ▪ verify ▪ place

A Geometric Approach to Guided Implant Placement

Page 3: Immediate placement   immediate load  #7 hlm

Initial X-ray

Page 4: Immediate placement   immediate load  #7 hlm

A full thickness flap was reflected

Page 5: Immediate placement   immediate load  #7 hlm

A periosteal elevator used to reflect the flap to a depth of 12 mm

Page 6: Immediate placement   immediate load  #7 hlm

Elevator positioned to indicate the 12 mm depth

Page 7: Immediate placement   immediate load  #7 hlm

Puros & Infuse Bone Graft (BMP2)

Page 8: Immediate placement   immediate load  #7 hlm

Site was closed with resorbable sutures

Page 9: Immediate placement   immediate load  #7 hlm

Graft was completed 6 months before implant placement

Page 10: Immediate placement   immediate load  #7 hlm

Guide Right™ Surgical Guide System

DéPlaque

▪ fabricate [diagnostic guide]▪ evaluate ▪ correct ▪ re-fabricate ▪ verify▪ place

Start With Precision. Place With Confidence.™

Page 11: Immediate placement   immediate load  #7 hlm

3/32” pilot drill used to drill initial hole with proposed implant trajectory in cast

Page 12: Immediate placement   immediate load  #7 hlm

3/32” hole drilled in cast

Page 13: Immediate placement   immediate load  #7 hlm

3 mm straight guide post in 3/32” holein preparation for fabrication of DIAGNOSTIC GUIDE

Page 14: Immediate placement   immediate load  #7 hlm

3 mm guide sleeve placed on 3 mm guide post with cleat positioned to the palate.

Page 15: Immediate placement   immediate load  #7 hlm

Triad® gel applied to the guide sleeve to capture the cleat & several of the adjacent teeth. Light cured to form the DIAGNOSTIC GUIDE

Page 16: Immediate placement   immediate load  #7 hlm

Guide Right™ Surgical Guide System

DéPlaque

▪ fabricate [diagnostic guide]

▪ evaluate ▪ correct ▪ re-fabricate ▪ verify▪ place

Guide Right™ Surgical Guide SystemStart With Precision. Place With Confidence.™

Page 17: Immediate placement   immediate load  #7 hlm

Invivo5 Anatomage

Cone Beam Analysis Software

Page 18: Immediate placement   immediate load  #7 hlm

axial cross sectional

tangential

4

volumetric

ANGULAR CORRECTION: 32° toward facial

virtual implant

#7

Page 19: Immediate placement   immediate load  #7 hlm

cross sectional high magnification

ANGULAR CORRECTION: 32° toward facial

4

# 7

Page 20: Immediate placement   immediate load  #7 hlm

axial cross sectional

HOME POSITION

tangential

4

volumetric

#7

Page 21: Immediate placement   immediate load  #7 hlm

cross sectional

HOME POSITION high magnification

4

Page 22: Immediate placement   immediate load  #7 hlm

Invivo5 Software

Navigating the System

For better understanding of use of Invivo5 software

view slide show at www.deplaque.com

Steps to Making & Correcting a Surgical Guide Steps to using Invivo5 for Evaluation

Page 23: Immediate placement   immediate load  #7 hlm

Using Invivo5 SoftwareSTART from the HOME POSITION ► the AXIAL view

► the view showing a virtual implant aligned with the image of the DIAGNOSTIC guide sleeve in Invivo5 software.

3 PLANES are viewed in the AXIAL view (A) the bucco-lingual / cross sectional plane may / may not display as a line intersecting the alveolar bone/ridge at 90º diagonally

(B) the mesio-distal plane / tangential plane (HOME POSITION)

(C) The IDEAL POSITION shown in the AXIAL PLANE is when the line intersecting the alveolar bone is 90º indicating the direction of the bucco-lingual plane being viewed.

STEP by STEP Evaluation

Page 24: Immediate placement   immediate load  #7 hlm

DéPlaque

▪ fabricate [diagnostic guide] ▪ evaluate ▪ correct ▪ re-fabricate [surgical guide]▪ verify▪ place

Guide Right™ Surgical Guide SystemStart With Precision. Place With Confidence.™

Page 25: Immediate placement   immediate load  #7 hlm

ANGULAR CORRECTIONS are made with the

Guide Right™ Bending Tool

Step by step instructions at end of slideshow

Page 26: Immediate placement   immediate load  #7 hlm

• Stylus placed over 2.5 mm

offset guide post

• Stylus used as a lever to gently bend the post to 32°

Guide Right™ Bending Tool

• Closeup: 2.5 mm offset guide post in bending tool block

Page 27: Immediate placement   immediate load  #7 hlm

Guide Right™ Surgical Guide System

DéPlaque

▪ fabricate [diagnostic guide]▪ evaluate ▪ correct ▪ re-fabricate [surgical guide]▪ verify▪ place

Start With Precision. Place With Confidence.™

Page 28: Immediate placement   immediate load  #7 hlm

2-Piece Lower-part 2.5 mm Offset Guide Post with angle correction of 32°

To begin preparation for fabrication of SURGICAL GUIDE:

2-Piece Lower-part guide post bent 32° is placed in the hole in the cast

Side View

Page 29: Immediate placement   immediate load  #7 hlm

3 mm guide sleeve added to 2.5 mm offset guide post

Page 30: Immediate placement   immediate load  #7 hlm

Buccal View

2.5 mm offset guide post with 3 mm guide sleeve

Page 31: Immediate placement   immediate load  #7 hlm

Drop of sticky wax applied in 2 applications to secure 3 mm guide post during Triad® application

1st drop

2nd drop

Page 32: Immediate placement   immediate load  #7 hlm

1ST application of Triad® gel to offset guide post capturing cleat to begin forming the SURGICAL GUIDE

Page 33: Immediate placement   immediate load  #7 hlm

Application sequence of Triad® gel to offset guide sleeve & adjacent teeth to form the SURGICAL GUIDE

• each application cured for 10 seconds & final application for required time •

Page 34: Immediate placement   immediate load  #7 hlm

Facial View

SURGICAL GUIDE

Guide Right™ 2-Piece 2.5 mm offset guide post corrected 32° in 3 mm guide sleeve.

Page 35: Immediate placement   immediate load  #7 hlm

SURGICAL GUIDE

2.5 mm offset guide post (corrected 32°) & 3 mm upper-part guide sleeve

Page 36: Immediate placement   immediate load  #7 hlm

DéPlaque

▪ fabricate [diagnostic guide] ▪ evaluate ▪ correct ▪ re-fabricate [surgical guide]▪ verify▪ place

Guide Right™ Surgical Guide SystemStart With Precision. Place With Confidence.™

Page 37: Immediate placement   immediate load  #7 hlm

3 mm guide sleeve in SURGICAL GUIDE to place a 3.3 Straumann Implant

Page 38: Immediate placement   immediate load  #7 hlm

DéPlaque

POST OP

Page 39: Immediate placement   immediate load  #7 hlm

Temporary Crown

Page 40: Immediate placement   immediate load  #7 hlm

Guide Right™

GUIDE POST BENDING TOOL

Steps to SINGLE BEND

Step 1 Place bending tool plate on a secure flat surface with the degree increments at the top & the stainless steel bar at the bottom.

Step 2 Locate the two 3/32” holes in the top of the stainless steel bar. The hole closest to the plate is used for all guide posts up to 3.0 mm offsets. The front hole is used for offsets 3.5 mm or larger. Place the bottom half of the guide post to be bent into the appropriate hole. Position the offset guide post in the hole determined by the planned direction of the correction. Tighten the set screw.

Step 3 Select the appropriate stylus to fit over the top half of the guide post.

Step 4 Fit the stylus over the guide post securely with the point directed at 0 ° & the bottom of the stylus in contact with the platform of 2-piece guide post or if no platform on post, in contact with block.

Step 5 Using the stylus as a lever, bend the guide post to the degree of angle of correction. You may need to ease the point of the stylus beyond the point of the desired degree.

Step 6 Remove the stylus. Loosen screw to remove the guide post bent to the desired angle.

Page 41: Immediate placement   immediate load  #7 hlm

Steps to COMPOUND BEND

Guide Right™

GUIDE POST BENDING TOOL

Step 1 Position a straight or offset guide post in the bending plate, tightening the set screw against one of the 8 flat surfaces on the lower half of the guide post.

Step 2 The 1st bend can be made to the right or left direction.

Step 3 The set screw is loosened & the guide post is rotated 90° next flat surface.

Step 4 The 2nd bend in the 2nd plane is made after rotating the guide post up away from the surface of the bending plate to register the stylus point back at 0º.

Step 5 Slide the stylus support bar down under the stylus until it supports the stylus. Tighten the side screws before making the 2nd bend.

Step 6 The 2nd bend can be made in either direction according to the X-ray.

Step 7 Remove the stylus and place the guide post back in the cast with the appropriate side indicated by a mark with a felt tip pen facing the buccal or lingual surface. Be sure the post is in the correct position.

Linear Corrections, using an offset guide post, must be determined & made before Angle Corrections.Offset 2-Piece Guide Posts available in the 3 mm guide post: 0.5,1, 1.5, 2.0, 2.5 & 3.0 mm.

Page 42: Immediate placement   immediate load  #7 hlm

LINEAR CORRECTIONS

are made with the

Guide Right™ guide posts & guide sleeve components

VIEW: step by step instructions in this slideshow & instructive case example slideshows on www.deplaque.com

Page 43: Immediate placement   immediate load  #7 hlm

DéPlaque

Guide Right™ Surgical Guide System

Offset Guide Posts

Page 44: Immediate placement   immediate load  #7 hlm

2-Piece Guide Post Straight Lower Piece with Upper Removable Piece

The bottom half of all Lower Pieces of the 2-Piece Guide Post are designed with 4 flat sides corresponding with the mesial, distal, buccal & lingual surfaces of the tooth.

Page 45: Immediate placement   immediate load  #7 hlm

2-Piece Guide Post

Upper Removable Piece

2.7 mm

Other diameters available on request.

Page 46: Immediate placement   immediate load  #7 hlm

For basic instruction for use of 2-Piece Guide Posts

View Slideshow at www.deplaque.com

“2-Piece Guide Post with STEPS to Making a Surgical Guide

featuring

Invivo5 Software Analysis”

Page 47: Immediate placement   immediate load  #7 hlm

To make Guide Sleeve Corrections …Correct the Guide Post

Linear Correctionsuse offset guide posts

0.5, 1, 1.5, 2, 2.5, 3, 3.5, 4 mm

Angular Corrections use Guide Right™ Bending Tool to correct

the angle of the guide posts & guide sleeve

Page 48: Immediate placement   immediate load  #7 hlm

view

Guide Right™

VIDEO Case HLM for actual site preparation & implant placement

www.deplaque.com

Featuring

2-Piece Offset Guide Posts Invivo5 Software

Triad® gel Application Sequence

Page 49: Immediate placement   immediate load  #7 hlm

Guide Right™ Surgical Guide System

Start With Precision. Place With Confidence.™

1.800.314.0065 • www.deplaque.com

fabricate ▪ evaluate ▪ correct ▪ verify ▪ place

DéPlaque

Guide Right™ Surgical Guide Systemfabricate ▪ evaluate ▪ correct ▪ re-fabricate ▪ verify ▪ place

A Geometric Approach to Guided Implant Placement