www.testolimited.com The data monitoring system testo Saveris measures the temperature and humidity values of sensitive goods and products in the environment, in processes and during transport. The easy-to-use measurement system delivers safety and savings in time and costs thanks to automated measurement data recording. In stationary operation, the transfer of the measurement data takes place via wireless and/or Ethernet connection to a base station. This documents and monitors all measurement data. If limit values are exceeded, a whole range of different alarm options, such as SMS/e-mail alarm or alarm relay is available. Remote alarms can even be given when the system is not connected to a running PC. testo Saveris works in many countries with a radio frequency of 868 MHz. The base is the heart of testo Saveris and can save 40,000 readings per measurement channel independently of the PC. This corresponds to around one year of memory capacity at a measuring rate of 15 minutes. - large internal store - Alarm via LED, relay - Display of system data and alarms - Energy supply via mains, additional emergency battery for data security graphical display, 4 control keys, Up to 150 probes can be connected, Interfaces: radio, Ethernet, USB (As this instrument is configured to your application, please call our Technical Sales Team for more information on 01420 544 433 ext. 203, Quotations available upon request)
Citation preview
Measurement data monitoring for the highest
demands:
The dispensary of Freiburg‘s University Medical Center
places the highest demands on the monitoring and
documentation of temperature and humidity data. For the
purposes of monitoring temperature during the preparation
of medicaments, or their storage in refrigerators, sensors
are used which not only record and save measurement
data, but can also trigger alarms if a limit value is exceeded.
With testo Saveris, a measurement data monitoring system
is offered by Testo AG which precisely and reliably records
and centrally archives measurement data. By ensuring the
storage conditions, the surplus quantities needing to be
dis-posed of in the preparation of administerable
medicaments is considerably reduced.
The University Medical Center Freiburg:
The University Medical Center in Freiburg is a maximum
care hospital. All special medical faculties are represented
here, with their own specialist clinics and institutes.
It is one of the largest medical facilities in Europe. In
addition to the over 66000 in-patients annually,
approximately 1000 out-patients are treated every day.
The University Medical Center combines patient care,
research and teaching under one roof. Roughly 10000 staff
members make it the largest employer in the Freiburg
region. Research at the Medical Center is focused or
planned according to the changing requirements of
modern medicine.
www.testolimited.com
Temperature monitoring in a hospital dispensary with testo Saveris.
Testo ReferenceUniversity Medical Center Freiburg
www.testolimited.com
Testo Reference University Medical Center Freiburg
The challenge:
The central chemotherapeutic agent and antiviral drug
preparation in the dispensary of the University Medical
Center Freiburg supplies all wards with patients‘ individual
medicaments. Not only in the production of injections,
infusion solutions, pump reservoirs or eyedrops, but also in
preparations for clinical studies, which are subject to
particularly stringent guidelines, is measurement data
monitoring indispensable for the uninterrupted
documentation of ambient conditions.
A router takes over the job of extending the transmission
distance in the specially shielded clean rooms.
If limit values are exceeded, various alarm options, such as
SMS/e-mail alarm or alarm relay are available. Remote
alarms can even be given when the system is not connected
to a running PC. Even in cases of power cuts, the recording
of data continues without interruption with testo Saveris. All
measurement data are stored automatically in a central data
base, and can be retrieved as required in the form of a
table or graph. The database also lists all occurring alarms.
The Saveris software is available in three different versions. The CFR version fulfils the requirements of the FDA 21 CFR
Part 11 and is thus validatable. "Parallel to temperature monitoring via the sensors in
the refrigerators, a continuous recording of
measurement data used to take place with additional
data loggers, which involved needing to regularly and consecutively analyse and reprogram them, then
place them back in the cleanrooms or refrigerators.“Dr. rer. med. Alexandra Schwehr
Specialist Pharmacist for Medicinal Product Information
University Medical Center Freiburg
"An additional simplification of the documentation
work is provided by the automatic creation of reports
in PDF format.“
Dr. rer. med. Alexandra SchwehrSpecialist Pharmacist for Medicinal Product Information University Medical Center Freiburg
More information.
More information and answers to all your questions
concerning measurement data monitoring with testo
Saveris at www.testolimited.com
The solution:
The measurement data monitoring system testo Saveris
consists of individually positionable probes and the so
called base station, which can be run selfsufficiently or
connected to a PC. The probes measure not only the
ambient temperature and humidity, at the same time they
also continuously save the data in definable cycles, and
transmit them at regular intervals by wireless or Ethernet to
the base station. Both probe variants can be combined into
one system. Due to spatial considerations, and because
the probes are placed in large numbers in various
refrigerators, only wireless probes are used in Freiburg‘s
University Medical Center dispensary.