How to control the hazards from asbestos fibre’s/ dusts during abatement works ?
A presentation focusing on controlling ASBESTOS during works within the built environment
AsbestosSerpentineChrysotileAmphibolesCrocidoliteGruneriteTremoliteActinoliteAnthophyllite
ControlDrivers
IndustryLegislative
Heal
th &
Saf
ety
Cultu
re
UK PARLIAMENT EUROPEAN PARLIAMENT
Legislation and Regulations
CLEAR STEP BY STEP
INSTRUCTIONS
IN THE
FORM
OF
Approved Codes of Practice
&Step by Step Guidance
Regional Priority Goal 4Preventing disease arising from chemical,
biological and physical environments
iii. We will act on the identified risks of exposure to carcinogens, mutagens and reproductive toxicants, including radon, ultraviolet radiation, asbestos and endocrine disruptors, and urge other stakeholders to do the same.
In particular, unless we have already done so, we will develop by 2015 national programs for elimination of asbestos-related diseases in collaboration with WHO and ILO
III. Strategy for elimination of asbestos related diseases (ARDs)When working with asbestos already in place, it is necessary to apply strict engineering measures to control exposure.• Encapsulation of the Work Site• Wet Processes• Local Exhaust Ventilation with Filtration• Effectiveness of Engineering Measures• Special Respirators• Special Facilities for Decontamination of Persons Involved in
Work with Asbestos• Medical Surveillance• National Registries of Workers Exposed to Asbestos with Data
Storage for at least 40 years incorporating• Monitoring Intensity, Frequency & Duration of exposure.
The preventive strategy should envisage measures to encourage voluntary efforts by INDUSTRY and be based on cooperation and consultation with the interested parties at national and enterprise levels.
“The product of individual and group values, attitudes, perceptions, competencies, and patterns of behaviour that determine the commitment to, and the style and proficiency of,
an organisation’s health and safety management”
No Man or Woman should die from being at work
Health & SafetyCulture
InnovationCommunication
Good Corporate
Governance
INDUSTRY
Training
Tool bo
x
Talks
Site Safety Inductions
Leadership
Commercial
acumen
Safety
Briefings
ACM's
Control Drivers
Legislation Health & SafetyCulture
IndustryInnovation
Hydrated RemovalMethodologies
DecontaminationAtmospheric Particle
Control Systems
PersonalDecontamination
EnvironmentalDecontamination
ACM TypeSprayed
Pre Formed SectionalHand Applied
NeedleProbe
InjectionSpray
ACM TypeBoardsPanelsPlates
PPE & RPE
Multi point Needle Injection
The single most effective methodology in use today in controlling the generation of respirable asbestos fibres, this system offers more protection to those who work on remove ACM’s from our built environment than the use of RPE.
The correct use of this system has shown that fibre concentrations can be reduced to below the control limit of 0.1f/cm³
Typical Surfactant Formulation
Wet Strip is an aqueous blend of non-ionic and anionic surfactants with a disclosing dye, formulated to produce maximum penetration into the asbestos matrix.
Wet Strip is designed for use in injection machines and can also be applied by spray for local wetting in hard to reach areas or when dry areas are found during removal.
The surfactants in Wet Strip will produce some level of flocculation of loose fibres back onto the matrix but treated areas should be wrapping in polythene to maintainhydration before removal.
ASBESTOS INSULATING BOARD PROBES
MOULDEDNEGATIVE PRESSURE UNITS
Negative Pressure Units
The principle purpose of these machines is to create a negative pressured environment to prevent the spread of air born/ respirable fibres.
Fundamental in the control of air born asbestos fibres within a controlled environment, the air extracted by these machines must pass through a High Efficiency Particulate Arrestor before venting.
Front Cover plate
Pre FilterHEPA Push Plate
HEPA Filter
NPU Body
Motor 110v/ 230v
Motor Plate Assembly
Manometer
RCBO 16AMP
Non Return Flap
Inlet Socket 110v/ 230v
HS-EM1The Harley Scientific Monitor (HS-EM1) is an instrument which measures air pressure differentials between enclosures placed under negative pressure via NPU’s and the external atmospheric air pressures, maintaining the negative pressure is a requirement of CAR2012 in the UK.
HS-EM1 Constantly monitors and gives real time information equally about the condition of the containment structure and the performance of the NPU’s, detecting variances in the pre-set negative pressure values within the enclosure HS-EM1 will trigger an audible alarm, and is capable of switching on automatically and instantly secondary negative pressure units, without the need of an Operative to intervene.
There is the option for the unit to send text alerts or communicate with other data centres over the internet or Bluetooth. All pressure recorded data is stored internally and can be printed direct from the unit or digitally transferred for processing and storage.
AFPT
Purpose built mobile decontamination units ranging from four man to large quads capable of processingsixteen men, this format can be converted to provide welfare units for large contracts where there are noon site welfare facilities.
Modular Decontamination Units
A flexible solution where space for mobile DCU’s does not exist
APF40 X 0.1F/CM³Equates to 4 Fibres
APF20 X 0.1F/CM³Equates to 2 Fibres