2
The information provided in this documentation contains general descriptions and/or technical characteristics of the performance of the products contained herein. This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications. It is the duty of any such user or integrator to perform the appropriate and complete risk analysis, evaluation and testing of the products with respect to the relevant specific application or use thereof. Neither Schneider Electric Industries SAS nor any of its affiliates or subsidiaries shall be responsible or liable for misuse of the information contained herein. Nov 3, 2011 1 Product data sheet Characteristics CAD32G7 contactor CAD-32 - 3 NO + 2 NC - instantaneous - 10 A - 120 V AC Main Range of product TeSys D control relay Product or component type Auxiliary contactor Device short name CAD Contactor application Control circuit Utilisation category AC-15 AC-14 Control circuit type AC Coil type Standard Suppressor technology Without built-in Pole contact composi- tion 3 NO + 2 NC [Uc] control circuit volt- age 120 V AC 50/60 Hz Connections - terminals Screwclamp terminal 1 cable 1...4 mm² - cable stiff- ness: solid - without cable end Screwclamp terminal 1 cable 1...4 mm² - cable stiff- ness: flexible - with cable end Screwclamp terminal 2 cable 1...2.5 mm² - cable stiffness: flexible - with cable end Screwclamp terminal 1 cable 1...4 mm² - cable stiff- ness: flexible - without cable end Screwclamp terminal 2 cable 1...4 mm² - cable stiff- ness: flexible - without cable end Complementary Contact operation Mechanically linked conforming to IEC 60947-5-1 Control circuit voltage limits 0.8...1.1 Uc operational 50 Hz 0.3...0.6 Uc drop-out 0.85...1.1 Uc operational 60 Hz [Ui] rated insulation voltage 690 V - overvoltage category III (pollution degree 3) - conforming to IEC 60947-5-1 600 V - certifications CSA 600 V - certifications UL [Uimp] rated impulse withstand voltage 6 kV conforming to IEC 60947 Tightening torque 1.7 N.m - on screwclamp terminal [Ue] rated operational voltage <= 690 V AC 25...400 Hz [Ith] conventional free air thermal current 10 A at <= 60 °C Irms rated making capacity 140 A at <= 690 V AC conforming to IEC 60947-5-1 Associated fuse rating 10 A gG at <= 690 V conforming to IEC 60947-5-1 Inrush power in VA 70 VA at 20 °C Hold-in power consumption in VA 8 VA at 20 °C 50 Hz Operating rate 3 cyc/s at 20 °C Operating time 4...12 ms coil de-energisation and NO opening 12...22 ms coil energisation and NO closing 4...19 ms coil energisation and NC opening 6...17 ms coil de-energisation and NC closing Minimum switching current 5 mA Minimum switching voltage 17 V Non-overlap time 1.5 ms on de-energisation between NC and NO contacts 1.5 ms on energisation between NC and NO contacts Insulation resistance > 10 MOhm Height 77 mm Width 45 mm MOHD. BIN AHMED AKBAR TRADING EST. (Electrical, Automation & Instrumentation) Al Sahaba Street | P.O Box 30073 | Jubail 31951 | Kingdom of Saudi Arabia Tel: 00966 (0) 13 3635225, 13 3618081 | Fax: 00966 (0) 13 363 3883 | [email protected] | www.akbartrading.com

TeSys D control relay Auxiliary contactor-控制继电器接触器辅助-제어 릴레이 보조 접촉기

Embed Size (px)

Citation preview

Page 1: TeSys D control relay Auxiliary contactor-控制继电器接触器辅助-제어 릴레이 보조 접촉기

The

info

rmat

ion

prov

ided

in th

is d

ocum

enta

tion

cont

ains

gen

eral

des

crip

tions

and

/or t

echn

ical

cha

ract

eris

tics

of th

e pe

rform

ance

of t

he p

rodu

cts

cont

aine

d he

rein

.Th

is d

ocum

enta

tion

is n

ot in

tend

ed a

s a

subs

titut

e fo

r and

is n

ot to

be

used

for d

eter

min

ing

suita

bilit

y or

relia

bilit

y of

thes

e pr

oduc

ts fo

r spe

cific

use

r app

licat

ions

.It

is th

e du

ty o

f any

suc

h us

er o

r int

egra

tor t

o pe

rform

the

appr

opria

te a

nd c

ompl

ete

risk

anal

ysis

, eva

luat

ion

and

test

ing

of th

e pr

oduc

ts w

ith re

spec

t to

the

rele

vant

spe

cific

app

licat

ion

or u

se th

ereo

f.N

eith

er S

chne

ider

Ele

ctric

Indu

strie

s SA

S no

r any

of i

ts a

ffilia

tes

or s

ubsi

diar

ies

shal

l be

resp

onsi

ble

or li

able

for m

isus

e of

the

info

rmat

ion

cont

aine

d he

rein

.

Nov 3, 20111

Product data sheetCharacteristics

CAD32G7contactor CAD-32 - 3 NO + 2 NC -instantaneous - 10 A - 120 V AC

MainRange of product TeSys D control relayProduct or componenttype

Auxiliary contactor

Device short name CADContactor application Control circuitUtilisation category AC-15

AC-14Control circuit type ACCoil type StandardSuppressor technology Without built-inPole contact composi-tion

3 NO + 2 NC

[Uc] control circuit volt-age

120 V AC 50/60 Hz

Connections - terminals Screwclamp terminal 1 cable 1...4 mm² - cable stiff-ness: solid - without cable endScrewclamp terminal 1 cable 1...4 mm² - cable stiff-ness: flexible - with cable endScrewclamp terminal 2 cable 1...2.5 mm² - cablestiffness: flexible - with cable endScrewclamp terminal 1 cable 1...4 mm² - cable stiff-ness: flexible - without cable endScrewclamp terminal 2 cable 1...4 mm² - cable stiff-ness: flexible - without cable end

ComplementaryContact operation Mechanically linked conforming to IEC 60947-5-1Control circuit voltage limits 0.8...1.1 Uc operational 50 Hz

0.3...0.6 Uc drop-out0.85...1.1 Uc operational 60 Hz

[Ui] rated insulation voltage 690 V - overvoltage category III (pollution degree 3) - conforming to IEC60947-5-1600 V - certifications CSA600 V - certifications UL

[Uimp] rated impulse withstand voltage 6 kV conforming to IEC 60947Tightening torque 1.7 N.m - on screwclamp terminal[Ue] rated operational voltage <= 690 V AC 25...400 Hz[Ith] conventional free air thermal current 10 A at <= 60 °CIrms rated making capacity 140 A at <= 690 V AC conforming to IEC 60947-5-1Associated fuse rating 10 A gG at <= 690 V conforming to IEC 60947-5-1Inrush power in VA 70 VA at 20 °CHold-in power consumption in VA 8 VA at 20 °C 50 HzOperating rate 3 cyc/s at 20 °COperating time 4...12 ms coil de-energisation and NO opening

12...22 ms coil energisation and NO closing4...19 ms coil energisation and NC opening6...17 ms coil de-energisation and NC closing

Minimum switching current 5 mAMinimum switching voltage 17 VNon-overlap time 1.5 ms on de-energisation between NC and NO contacts

1.5 ms on energisation between NC and NO contactsInsulation resistance > 10 MOhmHeight 77 mmWidth 45 mm

MOHD. BIN AHMED AKBAR TRADING EST.

(Electrical, Automation & Instrumentation)

Al Sahaba Street | P.O Box 30073 | Jubail 31951 | Kingdom of Saudi Arabia

Tel: 00966 (0) 13 3635225, 13 3618081 | Fax: 00966 (0) 13 363 3883 |

[email protected] | www.akbartrading.com

Page 2: TeSys D control relay Auxiliary contactor-控制继电器接触器辅助-제어 릴레이 보조 접촉기

2

Depth 86 mmProduct weight 0.58 kg

EnvironmentStandards VDE 0660

EN 60947-5NF C 63-140BS 4794IEC 60947-5-1

Product certifications CSAUL

IP degree of protection IP2x conforming to VDE 0106Protective treatment TH conforming to IEC 60068Ambient air temperature for operation -40...70 °C at Uc

-5...60 °C at 0.8...1.1 UcAmbient air temperature for storage -60...80 °COperating altitude 3000 m without derating in temperatureShock resistance 10 gn control relay open

15 gn control relay closedVibration resistance 2 gn 5...300 Hz control relay open

4 gn 5...300 Hz control relay closed