…Message Box ( Arial, Font size 18 Bold)

WHY CPU ?• IT MAKES COST-EFFECTIVE OPERATION OF BOILER

WATER SYSTEM:

• By reducing blow-down & make-up water requirements.

• Improvement in boiler water quality for drum type boiler.

• Quick start-up and as a result full load condition are

reached early.

• Orderly shutdown possible in case of condenser tube leak

condition.

• Improvement in quality of steam which results in enhanced

turbine life.

Page 5: Condensate Polishing Unit - CPU

…Message Box ( Arial, Font size 18 Bold)

WHAT IT CONTROLS• CPU CONTROLS:

• Corrosion (crud) transport.

• Ingress of impurity through make-up water.

• Condenser cooling water leaks.

Page 6: Condensate Polishing Unit - CPU

…Message Box ( Arial, Font size 18 Bold)

POTENTIAL FOULING SOURCES

Page 7: Condensate Polishing Unit - CPU

…Message Box ( Arial, Font size 18 Bold)

HOW IT CONTROLS• BY REMOVING:

• Dissolved contaminates: Chloride, Silica, Sodium etc.

• Suspended contaminates: Iron, Copper etc.

Page 8: Condensate Polishing Unit - CPU

…Message Box ( Arial, Font size 18 Bold)

WHAT AFFECTS ITS PERFORMANCE• FACTORS AFFECTING ITS PROCESS:

• Flow-rate

• Regeneration

• Composition of water to be treated

• Quality & quantity of treated water

Page 9: Condensate Polishing Unit - CPU

…Message Box ( Arial, Font size 18 Bold)

FLOW RATE• High flow rate results in:

I. Increased pressure: Lead to physical breakdown of resins due to osmotic stresses.

II. Large beads proportionately decreases the surface area available for ion exchange resulting in inferior quality of water.

• Low flow rate results in:

I. Inferior quality: Due to improper ion exchange for want of proper velocity with insufficient bed volume

Page 10: Condensate Polishing Unit - CPU

…Message Box ( Arial, Font size 18 Bold)

REGENERATION• At Service• R – H+ + NaCl → R – Na+ + HCl• R – OH- + HCl → R – Cl- + H2O

• At Regeneration• R – Na+ + HCl → R – H+ + NaCl • R – Cl- + NaOH → R – OH- + NaCl

• Reduces residual ions (cations and anions) leaked from the water system.

• CPU works on the same principle on which MB works in the DM plant.

Page 11: Condensate Polishing Unit - CPU

…Message Box ( Arial, Font size 18 Bold)

HOW ION EXCHANGE RESIN WORKS

Page 12: Condensate Polishing Unit - CPU

…Message Box ( Arial, Font size 18 Bold)

MIXED BED RESINS

Page 13: Condensate Polishing Unit - CPU

…Message Box ( Arial, Font size 18 Bold)

REGENERATION• Improper resin separation will result in inferior

outlet water quality because:

i) Anion resin will be converted to Cl- form

ii) Cation resin will be converted to Na+ form

Page 14: Condensate Polishing Unit - CPU

…Message Box ( Arial, Font size 18 Bold)

RESIN CLEANING METHODS• Back Washing: Prior to and after acid or caustic injection. Back

washing flow rates are such that bed expansion is 100% and whole beads are not lost during this process, fine/broken beads are also eliminated.

• Air Scrubbing/Rinsing Operation: Air scrubbing of resins is done in the tank with water up to resin top surface (for one minute), vessel pressurized with air (0·4 to 0.5 kg/cm2) and down flow rinse given by releasing pressure through rinse outlet for two minutes.

• Ultrasonic Cleaning: Ultrasonic cleaning devices have now been developed to clean the resins by ultrasonic transducers mounted outside a cleaning tank. The resin slurry is introduced from top of the tank with reverse water flow from bottom to top to carry away loosened crud and resin fines.

Page 15: Condensate Polishing Unit - CPU

…Message Box ( Arial, Font size 18 Bold)

CPU REGENERATION STATION

Page 16: Condensate Polishing Unit - CPU

…Message Box ( Arial, Font size 18 Bold)

REGENERATION STEPS

1. Transfer of the full resin charge from the operating vessel (MB) to

the cation regeneration tower CRT.

2. Transfer of the small mixed resin stored in the interface isolation

vessel IIV to the CRT.

3. Backwashing the resin in the CRT.

4. Transfer of the anion resin only from the CRT to the anion

regeneration tower ART.

5. Transfer of the small layer containing mixed resin to the IIV.

6. Acid injection in the CRT for regeneration of the cation resin which

doesn't contain any anion resin

Page 17: Condensate Polishing Unit - CPU

…Message Box ( Arial, Font size 18 Bold)

REGENERATION STEPS

7. Injection of caustic soda into ART for regeneration of the anion

resin which doesn't contain any cation resin; this can be made

simultaneously with step 6.

8. Transfer of the regenerated cation resin into the mixing and

storage vessel MSV.

9. Transfer of the regenerated anion resin into the mixing and

storage vessel MSV.

10. Mixing the resin in the MSV with clean air or nitrogen.

11. When needed, the regenerated resin charge is transferred

back to of the operating units

Page 18: Condensate Polishing Unit - CPU

…Message Box ( Arial, Font size 18 Bold)

Action to be taken for better efficiency• Cross contamination of resin to be tested after every 5

regenerations.• Screen testing of resin to be tested after every 10

regenerations.• Chloride content in caustic used for anion regeneration should

be compatible with rayon grade • A.R. grade ammonia to be used for boosting pH in

condensate. • Both cation and anion resin quantities are to be made up to

the design quantities so as to maintain their interface level in resin separation unit.

• Complete resin transfer from service vessel to regeneration vessel and vice versa to be ensured.

Page 19: Condensate Polishing Unit - CPU

…Message Box ( Arial, Font size 18 Bold)

Composition of Water to be Treated• Cation: Ammonia,

Copper,

Iron,

Sodium.

• Anion: Chloride,

Sulphate,

Phosphate,

Silica.

• Others: TSS & Residual TDS

Page 20: Condensate Polishing Unit - CPU

…Message Box ( Arial, Font size 18 Bold)

Quality & Quantity of Treated Water

• It largely depends upon leaching particularly Na

• H-Cycle gives ideal result

• NH3-Cycle susceptible in passing of Na more than in

comparison to H-Cycle.

Page 21: Condensate Polishing Unit - CPU

…Message Box ( Arial, Font size 18 Bold)

CYCLES OF DEEP BED MB• Hydrogen Cycle

• [RES]-H+ + NH4+ → [RES]-NH4+ + H+

• 7 days (168 Hours)

• Ammonia Cycle

• [RES]-NH4+ + Na+ → [RES]-Na+ + NH4+

• 14 days (336 Hours)

Page 22: Condensate Polishing Unit - CPU

…Message Box ( Arial, Font size 18 Bold)

CPU DESIGN OPTIONS

Cylindrical Mixed Bed Unit (4Mpa)

Page 23: Condensate Polishing Unit - CPU

…Message Box ( Arial, Font size 18 Bold)

CPU DESIGN OPTIONS

Spherical Mixed Bed Unit (>4MPa)

Page 24: Condensate Polishing Unit - CPU

…Message Box ( Arial, Font size 18 Bold)

Tentative Limiting ParametersParameters Units Normal Starting

Suspended Solids

ppb 10 100

Na+ ppb <1 <5

SiO2 ppb <10 <50

Fe ppb <5 <100

Cu ppb <3 <15

Cl- ppb <1 <10

Cation Cond. uS/cm <0.15 <0.2

pH - 6.7-7.5

TDS ppb <20 <50

Page 25: Condensate Polishing Unit - CPU

…Message Box ( Arial, Font size 18 Bold)

Tentative Limiting Parameters

• Condensate Temperature: a) Normal operating Temperature: < 50°C

b) Max. Temperature: 60°C

• Maximum Pressure Drop: <0.35MPa

Page 26: Condensate Polishing Unit - CPU

…Message Box ( Arial, Font size 18 Bold)

LIMITATIONS• Precautions should be taken to avoid the following:• In case of deep bed CPU, immediately after regeneration the bed

may leak-out some residual regenerant chemicals thus contaminating

feed water quality.

• Any disintegration of resin in CPU will directly cause contamination of

feed water by disintegrated resin.

• Since CPU is installed in the main steam water circuit, it may result in

operational disturbances such as excess pressure drop across CPU.

• Pressure and temperature of influent to CPU may not be always

compatible with the design conditions. This may impair the resin

characteristics.

Page 27: Condensate Polishing Unit - CPU

…Message Box ( Arial, Font size 18 Bold)

Equipment Description @ SPGCL

S. No. Equipment Description

1 Mixed Bed 3 No's/Unit

2 Flow (M3/Hr) 391

3 Max Pressure (Mpa) 4.0

4 Max Temperature (°C) 60

5 Max DP (Mpa) <0.2

Page 28: Condensate Polishing Unit - CPU

…Message Box ( Arial, Font size 18 Bold)

Presentation byRama Chandra Reddy Butcha

Group Head – Chemical & EnvironmentTata Power Company Limited

Page 29: Condensate Polishing Unit - CPU

…Message Box ( Arial, Font size 18 Bold)

Presentation byRama Chandra Reddy Butcha

Group Head – Chemical & EnvironmentTata Power Company Limited