http://www.waterproofingfew.com.au Phone: 03 8812 2918 Balconies which are designed with minimal fall require correct waterproof membrane application. Liquid Rubber is a seamless environmental flexible membrane.
Obviously membrane failure is caused by a variety of reasons
HoweverI have been in the construction game for over 30years,
either as a registered building practitionermyself or the owner of
F.E.W Waterproofing.Having construction knowledge does give me
anadvantage when trying to work out the structuralcauses of water
ingress.
Recent projects have highlighted an interesting cause for
waterproof membrane failure.
Balcony floors designed with minimal falls Construction methods
are always changing and adapting. I have recently noticed, either
for reasons of design and/or cost considerations, subtle changes
which have a direct impact on the success or otherwise of
waterproofing membranes.
Many balcony floors are constructed with minimal falls;
particularly evidenced in multi-level apartments.
Correct waterproof membrane is imperative with structures
designed with minimal falls.The membrane must be capable of ponding
waterand the application must proceed with meticulouspreparation to
ensure detailing is installed correctly.
Over the years we have become advocates ofLiquid Rubber
waterproof membranes - we have experienced great results where
other products have failed.
F.E.W Waterproofing is an independent companyWe choose the
product based on our knowledge,experience and the requirements of
the individualwaterproofing project.Liquid Rubber is our waterproof
membrane ofchoice with minimal fall balconies, roof tops,retaining
walls, below ground structures.
Liquid Rubber provides a seamless environmentally safe and
highly flexible membrane that will hold and contain water without
breaking down - not all products are capable of this.
The adhesive must be suitable to allow the field oftiles to
expand and contract during cyclic temperature changes.
It is imperative to insert balcony floor expansion joints
wherethe balcony floor abuts the vertical wall.This is particularly
important for large balconies; expansionjoints break up the field
and allow the tiles to expand andcontract.
Insufficient expansion joints can have a disastrous effect on
the success of a waterproof membrane. If tiles are forced up, the
membrane underneath will be damaged and guess what - WATER
LEAKS!
Leaking structures are a builders nightmare and major cause of
clients call back. NB: Dont let the waterproof membrane be damaged
by subsequent trades a constant on-site problem. NB: Water test the
membrane BEFORE tiling ensure the membrane is water tight.
Of course the best way to avoid these nightmares is to have
your Waterproofinginstalled correctly the First Time.
The F.E.W Waterproofing Team provide professional services.
F.E.W Waterproofing has three decades of CONSTRUCTION &
WATERPROOFING experience.We "Think like a Builder" and approach the
problem andprevention of water egress from a structural point of
view. Directly employed, fully certified waterproof technicians -
no subcontract labour. OH&S Compliant - Red Card, Elevated
Platform, Confined Spaces certificates. 10 yr Guarantees,
warranties and insurances Professional member AIW & MBAV