Please read all manuals provided with your equipment and follow the recommended safety precautions and techniques before use.
Creating useful, easy, real-time test labeling has to satisfy:
Creating useful, easy, real-time test labeling has to satisfy:
Creating useful, easy, real-time test labeling has to satisfy:
Creating useful, easy, real-time test labeling has to satisfy:
Creating useful, easy, real-time test labeling has to satisfy:
The combination of these guarantees reliable and traceable testing & reporting.
The combination of these guarantees reliable and traceable testing & reporting.
The combination of these guarantees reliable and traceable testing & reporting.
Creating and populating labels on the DELTA XRF Analyzer is a simple process.
First, the label names and options are created in a spreadsheet.
Then, the CSV version of the spreadsheet is imported into the DELTA XRF Analyzer.
This automatically creates the labels and their options.
This is a great way to reduce your analyzers setup time.
This is a great way to reduce your analyzers setup time.
The DELTA Labeling feature is extremely helpful in PMI situations such as:
The DELTA Labeling feature is extremely helpful in PMI situations such as:
The DELTA Labeling feature is extremely helpful in PMI situations such as:
The DELTA Labeling feature is extremely helpful in PMI situations such as:
The DELTA Labeling feature is extremely helpful in PMI situations such as:
The DELTA Labeling feature is extremely helpful in PMI situations such as:
In this scenario, a fabricator orders six seamless stainless steel 347 gray tubes, 2 in diameter
They should all be tested to ensure they are the grade ordered.
From the test window, pull the trigger and the label setup window opens.
Select all the options needed for this test.
Select all the options needed for this test.
Select all the options needed for this test.
Including the supplier of the item being tested
The type of item being tested.
The number of items being tested
The diameter of the item being tested.
And finally, who is performing the testing.
The Result field can be changed after the test is completed.
The DELTA can count the number of items being tested starting at one.
If the Part Count is left blank, the DELTA will not provide a count of items tested.
Once the label options have been chosen, you can start testing right from the labels screen.
Place the analyzer on the tube, pull the trigger and the test begins.
Place the analyzer on the tube, pull the trigger and the test begins.
The test results for the first tube is 347, the expected grade.
The test results for the first tube is 347, the expected grade.
It also shows the supplier field from the label window. The DELTA chooses the first label as the default, but you can change which label appears on each test.
When the trigger is pulled to start the next test
When the trigger is pulled to start the next test
the label window appears.
The part count increments to show that the second part is about to be tested.
Pull the trigger and the test commences.
Pull the trigger and the test commences.
The second tube is also the expected 347 grade.
Now, the third test.
It starts like the previous two tests
It starts like the previous two tests
with the label window appearing
And the part count now at three.
Pull the trigger and the test starts.
Pull the trigger and the test starts.
Pull the trigger and the test starts.
The results show that the tubing is 321 grade, not the expected 347.
The results show that the tubing is 321 grade, not the expected 347.
Tap the Info icon to open the Edit test info window
Tap the Info icon to open the Edit test info window
And change the result to Fail-grade
And change the result to Fail-grade
And change the result to Fail-grade
The fourth, fifth, and sixth tubes are all 347 grade.
The report, which can be used in any PMI software package will show the labels and results of this testing sequence.
The report, which can be used in any PMI software package will show the labels and results of this testing sequence.
Selecting a different set of labels to use is simple.
The in-service testing labels and their options have been created in a spreadsheet.
The CSV version of the spreadsheet has already been imported into the DELTA so it just needs to be selected.
The CSV version of the spreadsheet has already been imported into the DELTA so it just needs to be selected.
The CSV version of the spreadsheet has already been imported into the DELTA so it just needs to be selected.
Selecting the In-Service Labels file changes the labels that the DELTA will use.
Selecting the In-Service Labels file changes the labels that the DELTA will use.
Selecting the In-Service Labels file changes the labels that the DELTA will use.
Selecting the In-Service Labels file changes the labels that the DELTA will use.
The test going forward will have the In-Service labels.
The test going forward will have the In-Service labels.
The previous tests will retain the QC inspection labels
The previous tests will retain the QC inspection labels
Select the Component and
the Location on the component.
The Results field defaults to Accept, but if the test needs to be rerun this field can be changed to retest after the test is taken.
Place the analyzer on the sample, pull the trigger and the test begins.
Place the analyzer on the sample, pull the trigger and the test begins.
Place the analyzer on the sample, pull the trigger and the test begins.
For each test, the label window appears before the test starts.
Its a simple matter of changing the location of the test and the running the test.
Its a simple matter of changing the location of the test and the running the test.
Its a simple matter of changing the location of the test and the running the test.
The report, which can be used in any PMI software package, will show the labels and results of this testing sequence.
The report, which can be used in any PMI software package, will show the labels and results of this testing sequence.
In addition to creating a report from your test results, you can also print your results.
In addition to creating a report from your test results, you can also print your results.
The DELTA XRF Analyzer connects wirelessly to a Bluetooth printer, which is sold as an accessory.
You can print to a label, which can be used immediately to identify components tested
You can print to a label, which can be used immediately to identify components tested
You can print to a label, which can be used immediately to identify components tested
You can print to a label, which can be used immediately to identify components tested
You can print to a label, which can be used immediately to identify components tested
or you can print to receipt style paper to include with other documentation.
or you can print to receipt style paper to include with other documentation.
You can print the result as soon as the test is taken
or you can choose specific tests to print after testing is complete.
As you can see, whether PMI testing is for quality control or in-service testing, the approach to real time test labeling is simple.
As you can see, whether PMI testing is for quality control or in-service testing, the approach to real time test labeling is simple.
As you can see, whether PMI testing is for quality control or in-service testing, the approach to real time test labeling is simple.
As you can see, whether PMI testing is for quality control or in-service testing, the approach to real time test labeling is simple.
The DELTA XRF Analyzers real-time labeling feature is a valuable aid in gathering reliable test data that is critical for accurate PMI testing.
For more information, contact your local representative or visit us online.
For more information, contact your local representative or visit us online.