Upload
stefan-larsson
View
1.216
Download
0
Embed Size (px)
Citation preview
Stefan Larsson-Mastonstråle
Address : Bruksgatan 7, SE – 81494
Älvkarleö Bruk, Sweden
Tel: +46 (0)26 821 33
www.inresol.se
• Designer, Researcher, Inventor and Author
• Did military service in the Swedish Air Force
• Researcher at DalarnaUniversity
• Research manager at Vattenfall Power Utility R&D
• Have designed a number of renewable energy products and founded a number of companies since the 1980’s.
• Founder and Chairman of Inresol
Hybrid solar quadruple energy production
SFP turbine & PHEV
Solar fuel production
KIC innovation award
Address : Bruksgatan 7, SE – 81494
Älvkarleö Bruk, Sweden
Tel: +46 (0)26 821 33
www.inresol.se
• Current established sourcing of components is +5’000 units/month.
• Current manufacturing facility in Gävle capacity is >5000 units/month (all assembly automation not in place yet).
The Inresol factory in Gävle, Sweden
Address : Bruksgatan 7, SE – 81494
Älvkarleö Bruk, Sweden
Tel: +46 (0)26 821 33
www.inresol.se
GENIOUS™ portable CHP
Address : Bruksgatan 7, SE – 81494
Älvkarleö Bruk, Sweden
Tel: +46 (0)26 821 33
www.inresol.se
A ”turn-key” CHP system in
a boxFuel hopper with feeder
screw
Electronics box
Power generator
Backup cooler
radiator
Combustion chamber
Stirlingengine
Address : Bruksgatan 7, SE – 81494
Älvkarleö Bruk, Sweden
Tel: +46 (0)26 821 33
www.inresol.se
GENIOUS™ is energy independence
Address : Bruksgatan 7, SE – 81494
Älvkarleö Bruk, Sweden
Tel: +46 (0)26 821 33
www.inresol.se
Daily energy use in buildings
• The average load in a single family building are 0,8 – 1,2 kW • Peak loads occur in the evenings in residential and mid day in commercial (buildings)• Major loads as washer, dryer, compressor etc, are small in energy and high in power• The peak power is up to around 7kW in a majority of single family buildings• Hot water are typically 2-3kW in water heaters and 3-12 kW of room heating
Average load
Address : Bruksgatan 7, SE – 81494
Älvkarleö Bruk, Sweden
Tel: +46 (0)26 821 33
www.inresol.se
The Load adapted stirling power
generator
Address : Bruksgatan 7, SE – 81494
Älvkarleö Bruk, Sweden
Tel: +46 (0)26 821 33
www.inresol.se
Independent Power
& Grid Interaction
1-10kW(pre set)Grid power
Address : Bruksgatan 7, SE – 81494
Älvkarleö Bruk, Sweden
Tel: +46 (0)26 821 33
www.inresol.se
Annual energy output CHP
stirling system
Address : Bruksgatan 7, SE – 81494
Älvkarleö Bruk, Sweden
Tel: +46 (0)26 821 33
www.inresol.se
Internet connected CHP
• Smart KWh meter • Power control • O&M service• Payment options
Address : Bruksgatan 7, SE – 81494
Älvkarleö Bruk, Sweden
Tel: +46 (0)26 821 33
www.inresol.se
Grid interactive GENIOUS system
• GENIOUS owner can allow 1-20% of spare power to be purchased by the grid operator
• Grid operators can engage power from fuel and/or batteryby remote control
• The unit owner is always in control of his unit, so the “grid sell option” is a owner’s decision
• All present “Load management” internet based control standards can be used
Address : Bruksgatan 7, SE – 81494
Älvkarleö Bruk, Sweden
Tel: +46 (0)26 821 33
www.inresol.se
Off-Grid GENIOUS
system
• GENIOUS owner can use the power from fuel and/or battery• Electric power and hot water are produced• The CHP heat functionality is there but does not always
require a heat load• Solar PV modules can be connected directly to GENIOUS
Address : Bruksgatan 7, SE – 81494
Älvkarleö Bruk, Sweden
Tel: +46 (0)26 821 33
www.inresol.se
The virtual power plant
Address : Bruksgatan 7, SE – 81494
Älvkarleö Bruk, Sweden
Tel: +46 (0)26 821 33
www.inresol.se
1 Coal Power station :Average 1000 MW
Average cost : 750 mil €
Plus rail roads/grid connections, waste
water.
Operating cost approx 80 mil € / yr.
Average plant capacity factor is about
86%
100,000 Genious Portable systems :Average 1000 MW
(renewable dispatchable power)
Cost 20-30% below coal for 100,000 homes
depending on solar share of total capacity.
Operated as a Virtual Power Plant
With near zero climate impact & positive EBIT!
Where are we building the first virtual power plant?
Scale of VPP?