Electrical MeasuringInstruments
E
lect
rica
l Mea
suri
ng
Inst
rum
ents
Published by Iskra Sistemi, d. d. • Version 1.0, November 2011 • design Nimbus d.o.o.
®Iskra Sistemi, d. d., Stegne 21, SI-1000 Ljubljana Tel.: +386 1 513 10 00, Fax: +386 1 511 15 32 E-mail: [email protected], www.iskrasistemi.si
Index
1
Contents: PageMeasuringCentresMC320−Energymeter,MC330−Multimeter 3MC760/UMC760−NetworkAnalyzer,MC750/UMC750-NetworkRecorder 5MC740−MultifunctionMeter 7MC744−MultifunctionMeter,MC754−NetworkRecorder,MC764−NetworkAnalyzer 9MC660/MC666−NetworkAnalyzerforRailMounting 12MC650/MC656−NetworkRecorderforRailMounting 13MC640/MC646−MultifunctionMeterforRailMounting 14
MeasuringTransducersMT5x0/UMT5x0MeasuringTransducers 15MT560/UMT560−Transducer&Analyser 17MT550/UMT550−Transducer&Recorder 18MT540/UMT540−MultifunctionTransducer 18RD500−RemoteDisplayforMeasuringTransducersMT5x0/UMT5x0 19MT510/UMT510-PowerTransducer 20MT511/UMT511-PowerTransducer&Recorder 21MT516/UMT516-VoltageTransducer 22MT518/UMT518-CurrentTransducer 23MT406-ACVoltageselfpoweredTransducers 24MT408-ACCurrentselfpoweredTransducers 25MT416-ProgrammableACVoltageTransducers 26MT418-ProgrammableACCurrentTransducers 27MT440-MultifunctionalTransducers 28MT4xx-MeasuringTransducers 29MIBOX-Communicators 30MIQEN 32MISMART 34CommunicationAdaptersMI480−GSMDeviceforremotecontrol 36MI485−RS232/RS485Interface 38MI486,MI488−InterfaceTCP/IP 39DigitalMetersDigitalMeterswithLEDDisplay 40
SynchronizationMeters 42EnergyMeterswithPowerDisplay 43
HourMeters&PulseCountresHourMetersHK30-HK49 44PulseCountersSI63,SI64,SI65,MC703,MC723 45
Index
2
AnalogueMetersActiveorReactivePowerMeters 46PowerFactorMeters 47PointerFrequencyMeters 48ReedFrequencyMeters 49MeterwithLimitContact 50MetersforDCVoltageorCurrentwithMovingCoil 51TAPPositionMeterswithMovingCoil 52MetersforACVoltageorCurrentwithMovingCoilandaRectifier 54MetersforDCVoltageorCurrentwithMovingCoil 55MetersforACVoltageorCurrentwithMovingIron 56BimetalMaximumCurrentMeters 58CombinedBimetalMaximumCurrentMeters 59PhaseSequenceIndicatorandTemperatureMeters 60
PortableMeters
MI7033AnalogueMultiwattmeter 61Multimeters 62EducationalProgramme 63
MI7022DigitalTemperatureMeter 64EquipmentandAccessoriesShunts 65
CurrentMeasuringTransformers 66SpecialDemands 67
GeneralExplanations 68
DimensionalDrawings 72ConectionDiagrams 87InstrumentsConformitytoStandards 105
NOTE:DataaboutENERGYMETERScanbefoundinseparatebrochure.
3
MeasuringCentres
USEFor electricity distribution and energy productioncompanies, utilities, dwellings, energy managementsolutionproviders,industry,businessbuildings,design-ersofsmallpowerstations,panelbuilders,etc.
Main features are:• Measurementsofinstantaneousvaluesformorethan 60quantities(U,I,P,Q,S,PF,PA,f,j,THD,MD…)• 4Energycounters• Accuracy class U, I, P 0.5 (Active energy Class 1, optionalClass0.5S)• Largefrequencyrangefrom162/3Hzto400Hz• Upto2tariffinputs(option)• Upto2pulseorrelayoutputs(option)• ACorUniversal(option)powersupply• GraphicalLCD;128x64dotswithillumination• Automaticrangeofnominalcurrent(max.12.5A)and voltage(option)• User-adjustabledisplayofmeasurements• Multilingualsupport(13languages)• RS485orRS232communicationupto115,200bit/s (option)• MODBUScommunicationprotocolsupported• User-friendly PC MiQen software for setting via RS485orRS232communicationMeasurands
• RMSvaluesofcurrentsandvoltages(onlyMC330)• Measurementsofactive,reactive,apparentpowerandpowerfactor(onlyMC330)• Measurementsofenergyinall4quadrants• Averagevaluesofmeasurandsperinterval(onlyMC330)
Input / output modules Themodulesareavailablewithdoubleinputs/outputs.Eachmodulehasthreeterminals.Themeterisavailablewith-out,withoneorwithtwomodules.Thefollowingmodulesareavailable:• Outputmodule(relayversionMC330only) 2outputs• Tariffinput 2inputsOutputmoduleisavailableas:• OptooutputaccordingEN62053-31:2001(27V,27mA)• RelayoutputinMC330canbeusedforpulseoutputoralarmoutput(40V,1A).CommunicationOptioniscommunicationmoduleforreadingmeasuredval-uesandinstrumentsetting.AvailableisRS232orRS485communicationtypemodule.Communicationisgalvanicseparatedfromothercircuits.ForsettingwesuggestusingMIQENsoftware.SupplyStandardisACpowersupplyenablesconnectionofthemetertoACvoltage(57.7&63.5/100&110/230/400).OptionisauniversalpowersupplyenablesconnectionofthemetertoDC(20−300V)orACvoltage(48−276V/50Hz).MiQENMiQensoftwareis intendedforsupervisionofthemeteronPC.Itenablessettingmeterparametersthataretrans-ferredintotheinstrumentviacommunication(option).MultilingualsoftwarefunctionsonWindows98,2000,NT,XPoperatingsystems.
MC320-ENERGYMETER,MC330-MULTIMETER
MeasuringCentres
4
MULTIMETERMC330,ENERGYMETERMC320
AccuracyAccuracyispresentedaspercentagefromnominalvalueofthemeasurandexceptwhenitisstatedasanabsolutevalue.
Measurand Accuracy
Rmscurrent(I1,I2,I3,lavg,In,MD) 0.5
Rmsphasevoltage(U1,U2,U3,Uavg,MD) 25…600V 0.5
Phase-to-phasevoltage(U12,U23,U31,Uavg) 0.5
Frequency(f) 10mHz
Powerfactor(PF) 0.5
Phaseandphase-to-phaseangle(ϕ, ϕ12,ϕ23, ϕ31) 0.5°
Active,reactiveandapparentpower 0.5
Activeenergy EN62053-21 Class1
Reactiveenergy EN62053-23 Class2
Pulseoutput EN62053-31 ClassA&B
InputsInputssignals Current Voltage
Nominalfrequencyrange 50,60Hz
Measuringfrequencyrange 16-400Hz
Nominalvalue(In,Un) 1/5A 75,120,250,500VL-NMaximalvalue 12.5A 600VL-NConsumption <0.1VA <0.1VA
Power supplyPowersupply Universal AC
NominalvoltageAC 48-276V 57.7&63.5/100&110/230/400
Nominalfrequency 40-65Hz 40-65Hz
NominalvoltageDC 20-300V —
Consumption <3VA <3VA
Safety
Safety
ProtectionclasII
600vrms,installationcategoryII
300vrms,installationcategoryIII
Pollutiondegree2
incompliancewithEN61010-1:2002
Enclosurematerial PC/ABSIncombustibility-self-extinguishability,complyingwithUL94V-0
Enclosureprotection IP52(IP00forterminals)incompliancewithEN60529:1997
Reference conditionsAmbienttemperature -10…23…55°C
Voltageinput +/-20%Un
Voltageinputwithvoltageautorange 50…500V
Currentinput 0…100%In
Active/reactivepowerfactor cosϕ=1/sinϕ
Waveform sinus
Ambient conditionsTemperaturerangeofoperation -10to+55°C
Storagetemperaturerange -40to+70°C
Averageannualhumidity ≤75%r.h.
Dimensionaldrawingsonpage82.Connectiondiagramsonpages87.Softwareonpages32-35.
MeasuringCentres
5
Main features are:•EvaluationofthequalityofelectricvoltageincompliancewithEN50160(onlyMC760/UMC760)•Measurementsofinstantaneousvaluesofmorethan140quantities(U,I,P,Q,S,PF,PA,f,ϕ,THD,MD,energy,energypricebytariffs,etc.).•Accuracyclass0.5•Harmonicanalysisofphase,phase-to-phasevoltagesandcurrentsuptothe63thharmonic(onlyMC760/UMC760)•Recordingupto32measuredquantitiesandalarmsintheinternalmemory(8MBflash-MC760/UMC760,4MBflash-MC750/750)•Measurementsof40minimalandmaximalvaluesindifferenttimeperiods•32adjustablealarms•Widefrequencyrangefrom16Hzto400Hz•RS232/RS485communicationupto115,200bit/sorEthernetcommunication•MODBUSandDNP3communicationprotocol•MMCmemorycardfordatatransmission,settingandupgrading•Upto4inputsoroutputs(analogueoutputs,pulseoutputs,alarmoutputs,tariffinputs,pulseinput,analogueinput,bistablealarm,digitalinput)•UniversalorACpowersupply•GraphicalLCD128x64dotswithillumination•Automaticrangeofnominalcurrentupto5Aandnominalvoltageupto500V•Adjustabletariffclock,displayofelectricenergyconsumptioninoptionalcurrency•Multilingualsupport•User-friendlyPCMiQensoftware
MC760/UMC760-NETWORKANALYZER,MC750/UMC750-NETWORKRECORDER
USE The MC 760/UMC 760 network analyzer is used forpermanentanalysisofelectric voltagequality incom-pliance with the EN 50160 standard. Records arestoredintheinternalmemoryfortheperiodofthelast3 years. Moreover, more than 170,000 deviations ofthemeasuredquantitiesfromthestandardvaluesarestored,which enables findingof eventual reasons fortheproblemsonnetwork.Optionallimitsandrequiredquality inamonitoredperiodcanbedefinedforeachmonitoredcharacteristic.
Themetermeasuresandrecordsthefollowingcharacteristics:
•Frequencydeviations•Voltagedeviations•Voltagedips•Voltageinterruptions•Voltageunbalances•Over-voltages•Fastvoltagechanges•Flickerintensity•THD•Harmonics
MeasuringCentres
6
Handling the costsAspecialmeterfunctioniscostevaluationofenergy(active,reactiveandtotal)bytariffs.Themeteritselfenablestracingtheenergycostsinoptionalcurrency.Themetercalculatesconsumptioninoptionalcurrencybymeansoftheadjust-abletariffclockandelectricenergyprice.
Input / output modulesThemodulesareavailablewithdoubleinputs/outputsusingacommonconnectioncontact(exceptabistablealarmmodule-1output,3terminals).Themeterisavailablewithout,withoneorwithtwomodules.Thefollowingmodulesareavailable:
•Alarmoutput 2outputs•Analogueoutput 2x20mAoutputs•Pulseoutput 2outputs•Tariffinput 2inputs•Bistablealarmoutput1output•Additionalcommunicationport(COM2)•Pulseinput•AnalogueInput•Digitalinput
Dimensionaldrawingsonpage82.Connectiondiagramsonpages88,89.Softwareonpages32-35.
MC760/UMC760-NETWORKANALYZER,MC750/UMC750-NETWORKRECORDER
MeasuringCentres
7
USEThe MC 740 multifunction meter is used formonitoring and measuring electrical quantities ofa three-phase electric-energy distribution system.The meter is provided with 32 program adjust-able alarms, up to four inputs or outputs andcommunication.Themetercanbesetandmeas-urements can be checked with the RS 232/RS485 or Ethernet communication. The meter alsofunctions as an electricity meter, with the addi-tional function of cost management by tariffs. Atariff input or a tariff clock can be set. At tariffclock setting, four periods and four work groupsas well as electric energy price for each periodand a work group (16 different price periods) areavailable. Additionally, 20 places are available forsettingholidaysordayswhenspecialtariffrulesarevalid.Asanelectricitymeteritrecordsenergyinallfourquadrantsinfourtariffs.
Main features are:•Measurementofinstantaneousvaluesofmorethan130quantities(U,I,P,Q,S,PF,PA,f,ϕ,MD,energy,energypricebytariffs,etc.).•Accuracyclass0.5•Measurementof40minimumandmaximumvaluesindifferenttimeperiods•32adjustablealarms•Widefrequencyrangefrom16Hzto400Hz•RS232/RS485communicationupto115,200bit/sorEthernetcommunication•MODBUSandDNP3communicationprotocols•MMCmemorycardforsettingandupgradingthemeter•Upto4inputsoroutputs(analogueoutputs,pulseoutputs,alarmoutputs,tariffinputs,pulseinput,analogueinput,bistablealarm,digitalinput)•UniversalorACpowersupply•GraphicLCD128x64dotswithillumination•Automaticrangeofnominalcurrentupto5Aandnominalvoltageupto500V•Adjustabletariffclock,displayofelectricenergyconsumptioninoptionalcurrency•Multilingualsupport•User-friendlyPCMiQensoftware
MC740/UMC740-MULTIFUNCTIONMETER
MeasuringCentres
8
Handling the costsAspecialmeterfunctioniscostevaluationofenergy(active,reactiveandtotal)bytariffs.Themeteritselfenablestracingtheenergycostsinoptionalcurrency.Themetercalculatesconsumptioninoptionalcurrencybymeansoftheadjust-abletariffclockandelectricenergyprice.
Input / output modulesThemodules are availablewithdouble inputs/outputs using a commonconnection contact (except abistable alarmmodule-1output,3terminals).Themeterisavailablewithout,withoneorwithtwomodules.Thefollowingmodulesareavailable:•Alarmoutput 2outputs•Analogueoutput 2x20mAoutputs•Pulseoutput 2outputs•Tariffinput 2inputs•Bistablealarmoutput 1output•Pulseinput•AnalogueInput•Digitalinput
Dimensionaldrawingsonpage82.Connectiondiagramsonpages88,89.Softwareonpages32-35.
MC740/UMC740-MULTIFUNCTIONMETER
MeasuringCentres
9
MC764-NETWORKANALYZER,MC754-NETWORKRECORDER,MC744-MULTIFUNCTIONMETER
DESCRIPTION
Themeterisintendedformeasuring,analysingandmonitoringsingle-phaseorthree-phaseelectricalpowernetwork.ThemetermeasuresRMSvalueaccordingtotheprincipleoffastsamplingofvoltageandcurrentsignals.Abuilt-inmicroprocessorcalculatesmeasurands(voltage,current,frequency,energy,power,powerfactor,THDphaseangles,etc.)fromthemeasuredsignals.
USE
MetersfromMC7x4seriesaredesignedforenvironmentswherebesidemeasurementofthree-phaseelectricalpowernetworkadditionalanalogueordigitalmeasurements/controlsmustbemadewithoutadditionalhardware(PLC,OPLC,...).Metersarehousedinenclosure144mmx144mm.
Features:
• Alarmorrelayoutputs• Digitalinputs/outputs• Analogueoutputs/inputs• EvaluationoftheelectricitysupplyqualityincompliancewithEN50160(onlyMC764)• Measurementsofinstantaneousvaluesofmorethan140quantities(U,I,P,Q,S,PF,PA,f,ϕ,THD,MD, energy,energycostbytariffs,etc.)• Accuracyclass0.5(optional0.2)• Harmonicanalysisofphase,phase-to-phasevoltagesandcurrentsuptothe63rdharmonic(onlyMC764)• Recordingupto32measurandsand32alarmsintheinternalmemory(onlyMC754/764)• Measurementsof40minimalandmaximalvaluesindifferenttimeperiods• 32adjustablealarms• Frequencyrangefrom16Hzto400Hz• RS232/RS485communicationupto115,200bit/sorEthernet&USBcommunication• MODBUSandDNP3communicationprotocol• MMC/SDcardfordatatransmission,settingandupgrading• Upto4inputsoroutputs(analogueoutputs,pulseoutputs,alarmoutputs,tariffinputs,pulseinput,analogueinput, bistablealarm,digitalinput)• AdditionalI/Omoduleswithupto16digitalinputsoroutputs,orupto8analogueoutputs• Additionalcommunicationport(COM2)• Universalpowersupply• GraphicalLCD;128x64dotswithillumination• Automaticrangeofnominalcurrentandvoltage(max.12.5Aand750V)• Adjustabletariffclock,displayofelectricenergyconsumptioninoptionalcurrency• Multilingualsupport• User-friendlyPCMiQensoftware• Additionalanalogueordigitalmeasurements/controlscanbemadewithoutadditionalhardware(PLC,OPLC,etc.)
Dimensionaldrawingsonpage82.Connectiondiagramsonpages90.Softwareonpages32-35.
MeasuringCentres
10
FAMILYOFMC7x0/UMC7x0,MC7x4-COMPARISONANDCOMMONCHARACTERISTICS
INSTRUMENT
DIN96 MC744 MC754 MC764 MC740 MC750 MC760
ANSI100 - - - UMC740 UMC750 UMC760
Hardwareconfiguration
BacklightLCD128x64 • • • • • •
Keyboardkeys 5 5 5 5 5 5
LEDindicator(SDorMMC/com./alarm) •/•/• •/•/• •/•/• •/•/• •/•/• •/•/•
SlotforSD/MMCcard • • • • • •
Powersupply Universal Universal Universal Univ.,AC Univ.,AC Univ.,AC
Energymeters 4 4 4 4 4 4
Realtimeclock • • • • • •
Internalflashmemory - 8Mb 8Mb - 4Mb 8Mb
AutoRangeCurrent • • • • • •
AutoRangeVoltage • • • • • •
Communication(COM1)
Communicationports 1 1 1 1 1 1
RS232&RS485/Ethernet&USB •/º •/º •/º •/º •/º •/ºModbusandDNP3 • • • • • •
InputsandOutputs(I/O)
I/OSlot1(2PO/2PI/2TI/2AL/2AI/2PI/1BA
/2AN/2DI/COM2)º/º/º/º/º/
º/º/º/º/-º/º/º/º/º/
º/º/º/º/-º/º/º/º/º/
º/º/º/º/-º/º/º/º/º/
º/º/º/º/-º/º/º/º/º/
º/º/º/º/-º/º/º/º/º/
º/º/º/º/-
I/OSlot2(2PO/2PI/2TI/2AL/2AI/2PI/1BA
/2AN/2DI/COM2*)º/-/º/º/º/
º/º/º/º/º
º/-/º/º/º/
º/º/º/º/º
º/-/º/º/º/
º/º/º/º/º
º/-/º/º/-/º/
º/º/º/º
º/-/º/º/-/º/
º/º/º/º
º/-/º/º/-/º/
º/º/º/ºI/OSlot3(8AL/8DO/8DI/4AN/4AIR/4AIU
/4AII)º/º/º/º/
º/º/º
º/º/º/º/
º/º/º
º/º/º/º/
º/º/º- - -
I/OSlot4(8AL/8DO/8DI/4AN/4AIR/4AIU
/4AII)º/º/º/º/
º/º/º
º/º/º/º/
º/º/º
º/º/º/º/
º/º/º- - -
Availablefunctions
Setupwizard • • • • • •
Wrongconnectionwarning • • • • • •
Customscreens • • • • • •
Resetdefaultsettings • • • • • •
Programmablerefreshtime • • • • • •
MDcalculation(TF,FW,SW) •,•,• •,•,• •,•,• •,•,• •,•,• •,•,•
Tariffclock • • • • • •
Costmanagement • • • • • •
Programmablealarms 32 32 32 32 32 32
Alarmsrecording - • • - • •
Measurementsrecording - • • - • •
EN50160analysis - - • - - •
PCsoftware MIQen MIQen MIQen MIQen MIQen MIQen
Availablemeasurements
Actualvalues:U,I,P,Q,S,PF,PA,f,ϕ • • • • • •
Energy • • • • • •
Maximumdemands • • • • • •
Minimumvalues:U,I,P,Q,S,PF,PA,f,ϕ • • • • • •
Maxiumvalues:U,I,P,Q,S,PF,PA,f,ϕ • • • • • •
THD(actual) • • • • • •
Harmonics Upto31st Upto31st Upto63rd Upto31st Upto31st Upto63rd
*AdditionalCOM2
MeasuringCentres
11
FAMILYOFMC7x0/UMC7x0,MC7x4-COMPARISONANDCOMMONCHARACTERISTICS
Legend:- -featurenotsupported• -MChasfeatureº -optionalfunctionPO-pulseoutputPI-pulseinputTI-tariffinputAL-alarmoutput
INPUTS
Inputsignals Current Voltage
Nominalfrequencyrange 50−60Hz
Measuringfrequencyrange 162/3−400Hz
Nominalvalue(In,Un)* 5A 500VL-N
Maximumvalue(sinuscurve) 12,5A 750VL-N
Rating 1−5A 57,7−500VL-N
Consumption <0,1VA <0,1VA
*Automaticrange
POWERSUPPLY
Supply Universal AC
PowerSupply 48−276V57,7/63,5/100/110/230/
400500V
NominalvoltageAC 40−65Hz 40−65Hz
Nominalfrequency
NominalvoltageDC 20−300V −
Consumption <10VA* <8VA
*ConsumptionatMC7x0familyis<7VA
ACCURACYMeasuredquantity Accuracy
Rmscurrent(I1,I2,I3,Iavg,In) 0,5(optional0,2)
Rmsphasevoltage(U1,U2,U3,Uavg) 62.5−750V 0,5(optional0,2)
Phase-to-phasevoltage(U12,U23,U31,Uavg) 0.5(optional0,2)
Frequency(f) 0.02
Powerfactor(PF) 0.5
Phaseandphase-to-phaseangle(ϕ,ϕ12,ϕ 23,ϕ 31) 0.5
THD 0…400% 0.5
Activepower 0.5(optional0.2)
Reactivepower 1.0(optional0.5)
Apparentpower 1.0(optional0.5)
Activeenergy EN62053-21 Class1(optional0.5S)
Reactiveenergy EN62052-23 Class2
Realtimeclock 1min./month(30ppm)
Analogueoutput +-0.2mA
AN-analogueoutputAI-analogueinputBI-bistablealarmDI-digitalinputTF-thermalfunctionFW-fixedwindowSW-slidingwindowCOM-additionalcommunicationport(COM2)
MeasuringCentres
12
USEThe instrument isused forpermanentanalysisof elec-tricity supply quality in compliance with the EN 50160standard.Apartition inthe internalmemory isreservedfor storing reports foraperiodof the last sevenyears.The internal memory capacity enables storing of morethan170,000variationsof themeasurements from thestandardvalues,whichenablesfindingeventualreasonsfortheproblemsinnetwork.Limitsandrequiredqualityinamonitoredperiodcanbedefinedforeachmonitoredcharacteristic.Thefollowingcharacteristicsaremeasuredandrecorded:•Frequencyvariations•Voltagevariations•Voltageunbalances•Voltagedips•Voltageinterruptions•Rapidvoltagechanges•FlickersPst&Plt•Temporaryovervoltages•THD's•Harmonics
FEATURES:
- EvaluationoftheelectricitysupplyqualityincompliancewithEN50160- Measurementsofinstantaneousvaluesofmorethan150quantities(U,I,P,Q,S,PF,PA,f,ϕ,THD,MD, energy,energycostbytariffs,etc.)- Accuracyclass0.5- Harmonicanalysisofphase,phase-to-phasevoltagesandcurrentsuptothe63rdharmonic- Recordingupto32measurementsand32alarmsintheinternalmemory(8MBflash)- Measurementsof40minimalandmaximalvaluesindifferenttimeperiods- 32adjustablealarms- Frequencyrangefrom16Hzto400Hz- RS485communicationupto115.200bit/s- MODBUSandDNP3communicationprotocol- Upto4(2+2)inputsoroutputs(pulseoutputs,alarmoutputs,tariffinputs,digitalinputs)- Universalpowersupply48-276VAC,20-300VDC- GraphicalLCD;128x64dotswithillumination- Direct65Aconnection(MC666)- CT5Aconnection(MC660)- HousingforDINrailmounting- Adjustabletariffclock,displayofelectricenergyconsumptioninoptionalcurrency- Multilingualsupport- User-friendlyPCMiQensoftware
Dimensionaldrawingsonpage82.Connectiondiagramsonpages91,92.Softwareonpages32-35.
MC660/MC666NETWORKANALYZERFORRAILMOUNTING
MeasuringCentres
13
USEThe instrument is used for monitoring, measuringandrecordingmeasurementsofelectricquantitiesofelectricalpowerdistributionsystem.Upto32meas-urements and up to 32 alarms are recorded in theinternal memory. The memory is separated into twosectionsformeasurements(AandB)andonesectionfor recordingalarms.Thememorydivision isdefinedbytheuserviacommunication.
FEATURES:
- Measurements of instantaneous values of more than 150 quantities (U, I, P, Q, S, PF, PA, f, ϕ, THD, MD, energy,energycostbytariffs,etc.)- Accuracyclass0.5- Harmonicanalysisofphase,phase-to-phasevoltagesandcurrentsuptothe31stharmonic- Recordingupto32measurementsand32alarmsintheinternalmemory(8MBflash)- Measurementsof40minimalandmaximalvaluesindifferenttimeperiods- 32adjustablealarms- Frequencyrangefrom16Hzto400Hz- RS485communicationupto115.200bit/s- MODBUSandDNP3communicationprotocol- Upto4(2+2)inputsoroutputs(pulseoutputs,alarmoutputs,tariffinputs,digitalinputs)- Universalpowersupply48-276VAC,20-300VDC- GraphicalLCD;128x64dotswithillumination- Direct65Aconnection(MC656)- CT5Aconnection(MC650)- HousingforDINrailmounting- Adjustabletariffclock,displayofelectricenergyconsumptioninoptionalcurrency- Multilingualsupport- User-friendlyPCMiQensoftware
MC650/MC656NETWORKRECORDERFORRAILMOUNTING
Dimensionaldrawingsonpage82.Connectiondiagramsonpages91,92.Softwareonpages32-35.
MeasuringCentres
14
USEThe instrument is used for monitoring and measuringelectricquantitiesofthree-phaseelectricalpowerdistribution system. The meter is provided with 32program adjustable alarms, a serial communicationport, two pulse (alarm) outputs and two tariff (digital)inputs.ThemetercanbesetandmeasurementscanbecheckedwiththeRS485communication.Themeteralsofunctionsasanenergycounter,withtheadditionalfunc-tionofcostmanagementbytariffs.Atariffinputoratariffclockcanbeset.Attariffclocksetting,fourseasonsandfourdaygroupsaswellasenergycostforeachperiodandadaygroup(16differentcostperiods)areavailable.Additionally,20placesareavailableforsettingholidays.As an energy counter it can record energy in all fourquadrantsinfourtariffs.
FEATURES •Measurementsofinstantaneousvaluesofmorethan150quantities(U,I,P,Q,S,PF,PA,f,ϕ,MD,energy, energycostbytariffs,etc.)•Accuracyclass0.5•Harmonicanalysisofphase,phase-to-phasevoltagesandcurrentsuptothe31stharmonic•Measurementsof40minimalandmaximalvaluesindifferenttimeperiods•32adjustablealarms•Frequencyrangefrom16Hzto400Hz•RS485communicationupto115,200bit/s•MODBUSandDNP3communicationprotocol•Upto4(2+2)inputsoroutputs(pulseoutputs,alarmoutputs,tariffinputs,digitalinputs)•Universalpowersupply48-276VAC,20-300VDC•GraphicalLCD128x64dotswithillumination•Direct65Aconnection(MC646)•CT5Aconnection(MC640)•HousingforDINrailmounting•Adjustabletariffclock,displayofelectricenergyconsumptioninoptionalcurrency•User-adjustabledisplayofmeasurements•Multilingualsupport•User-friendlyPCMiQensoftware
MC640/MC646MULTIFUNCTIONMETERFORRAILMOUNTING
Dimensionaldrawingsonpage82.Connectiondiagramsonpages91,92.Softwareonpages32-35.
MeasuringTransducers
15
StandardEN Description
61010-1:2001Safetyrequirementsforelectricalequipmentfor
measurement,controlandlaboratoryuse
60688:1995/
A2:2001
Electricalmeasuringtransducersforconverting
ACelectricalvariablesintoanalogueanddigital
signals
50160:2010Voltagecharacteristicsofelectricitysuppliedby
publicdistributionnetworks
61326-1:2006
EMCrequirementsforelectricalequipmentfor
measurement,controlandlaboratoryuse-
Part1:Generalrequirements
60529:1997/
A1:2000
Degreesofprotectionprovidedbyenclosures
(IPcode)
60068-2-1/-2/
-6/-27/-30
Environmentaltesting(-1Cold,-2Dryheat,
-30Dampheat,-6Vibration,-27Shock)
UL94Testsforflammabilityofplasticmaterialsforparts
indevicesandappliances
MiQen
MT5x0/UMT5x0-Comparisonandcommoncharacteristics
MainfeaturesofallMT5x0/UMT5x0MeasuringTransducers•Accuracy0.2(IECEN60688),0.1(oncommunication)•4I/Omodules: -upto4analogueoutputs -upto4analogueinputs -upto4digitalinputs -upto4digitaloutputs -upto4pulseoutputs -upto2tariffinputs -upto4alarms -withcombinationofpreviouslylistedinputs/outputs -watchdogrelayoutput•AnadditionalCOM2serialcommunicationmodule canbesetinsteadofthe4thI/Omodule•Pulseoutputscanbesetseparatelyforthechosen tariffandforalltariffstogether•Forananalogueoutputwiththeranges+/-20 mAand+/-10V,otherrangesaresetwithsoftware• Analogueinputssupportbipolarvoltage(+/-10V)or bipolarcurrent(+/-20mA)ortwo-wiretemperature (PT1000;-200°Cto+850°C)andresistance(upto4kΩ)• 2communicationports: -COM1:3waysofcommunication,alwaysjustoneavailable:serial(RS232/485)orUSBorEthernet&USB• Communicationprotocols:Modbus(115,200b/s),DNP3•Atransducersautomaticallydetectscommunication protocole(MODBUS/DNP3)• Frequencyranges:162/3Hz/45-65Hz/400Hz• Real-timeclock• Universalauxiliarysupply•DimensionUMT5x0160mm(weight)x75mm (height)x125mm(depth)•UserfriendlyandpowerfulsettingssoftwareMiQen
Table1:Compliancewithstandards
Tariff inputs:•Nominalvoltage-Un:230V•Voltagesupply:0.8..1,15Un•Currentatnominalvoltage<0.5mA•Tariffinputsareelectricallyisolatedfrom othercircuits.
MeasuringTransducers
16
* Uni-LO:lowvoltage(45...70VAC,19...70VDC);Uni-HI:highvoltage(70...276VAC,70...300VDC)** Withsomelimits(seeUser'sManualMT/UMT5x0)***Theoptionalcommunicationport(COM2)excludestheremoteLEDdisplayconnectionandsupportsonlyRS485serialcommunicationtypethroughthe4thI/Oconnectorslot
Legend: - -featurenotsupported •-standardfeature -optionalfeaturePO -pulseoutput TI -tariffinputAL -alarmoutput
Instrument Description MultifunctionTransducer NetworkRecorder NetworkAnalyzer
ANSItype UMT540 UMT550 UMT560
DINtype MT540 MT550 MT560
Hardware Configuration
Accuracyclass(typical,ofreading)% 0.2 0.2 0.2
Powersupply Uni-LO/Uni-HI* Uni-LO/Uni-HI* Uni-LO/Uni-HI*
Energycounters 4 4 4
Realtimeclock • • •
Remotedisplayconnection*** • • •
FLASHMemorysize - 8Mb 8Mb
AutorangeCurrent • • •
AutorangeVoltage • • •
Input Range
Current-In=5A,max.12A • • •
Voltage-Un=500VL-N,max.750VL-Nsin • • •
Frequency-162/3Hzor45to65Hzor300Hzor400Hz • • •
Communication
Communicationports 1Standard+1Optional*** 1Standard+1Optional*** 1Standard+1Optional***
Comm.type:Serial(RS485+RS232)/Ethernet/USB/Ethernet&USB** •/•/-/• •/•/-/• •/•/-/•
Comm.protocol:Modbus(RTU,TCP)andDNP3 • • •
Inputs/Outputs
I/O1:AN/DI/DO/PO/TI/AL / / / / / / / / / / / / / / /
I/O2:AN/DI/DO/PO/TI/AL / / / / / / / / / / / / / / /
I/O3:AN/DI/DO/PO/TI/AL / / / / / / / / / / / / / / /
I/O4:AN/DI/DO/PO/TI/AL/COM2* / / / / / / / / / / / / / / / / / /
Available Functions
Programmablerefreshtime(Communication) • • •
MDcalculation(TF,FW,SW) • • •
Tariffclock • • •
Costmanagement • • •
Programmablealarms 32 32 32
Alarmsrecording - • •
Measurementsrecording - • •
PowersupplyqualityEN50160 - - •
PCSoftware MiQen MiQen MiQen
Available Measurements
Actualvalues:U,I,P,Q,S,PF,PA,f, ϕ • • •
Energy • • •
Maximumdemands • • •
Minimumvalues:U,I,P,Q,S,PF,PA,f, ϕ • • •
Maximumvalues:U,I,P,Q,S,PF,PA,f, ϕ • • •
THD • • •
Harmonics upto31st upto31st upto63rd
AN-analogueoutput DI-digitalinput DO-digitaloutput TF-thermalfunctionFW-fixedwindowSW-slidingwindow /-or
MT5x0/UMT5x0-Comparisonandcommoncharacteristics
MeasuringTransducers
17
The transducer measures and records the following characteristics: • Frequencydeviations• Voltagedeviations• Voltageclips• Voltageinterruptions• Voltageunbalances• Over-voltages• Fastvoltagechanges• Flickerintensity• THD• Harmonics
Besidesthefeatureslistedinthechapter“FamilyofMeasuringTransducersMT5x0/UMT5x0-comparisonandcommoncharacteristics”,thetransduceralsohasotherfeatures:• Harmonicanalysisofphase,phase-to-phasevoltagesandcurrentsuptothe63rdharmonic(onlyMT/UMT560)• 32adjustablealarms• Recordingupto32measurandsand32alarmsintheinternalmemory(8MBflash)
Dimensionaldrawingsonpage81.Connectiondiagramsonpages94-97.Softwareonpages32-35.
MT560/UMT560-TRANSDUCER&ANALYZER
USE The MT 560/UMT 560 multi transducer andanalyzer is used for a permanent analysis ofelectricity supply quality in compliance with theEN 50160 standard. Records are stored in theinternal memory for the period of the last threeyears. Moreover, more than 100,000 deviationsof the measurands from the standard values arestored,whichenablesfindingeventualreasonsfortheproblemsinnetwork.
Input ranges width enables measurement of allbasic AC voltages and currents. The transducergenerates and accepts different I/O signals.Ananalogueoutputsignalisproportionaltomea-surandandisintendedforthecontrolofanalogueanddigitaldevices.Apulseoutputisintendedforsendingdatatodevicesforcheckingandsupervis-ingconsumedenergy.
MeasuringTransducers
18
USETheMT550/UMT550transducerandanalyzerisusedformonitoring,measuringandrecordingmeasurementsofelectricquantitiesinelectricalpowerdistributionsystem.Measurementsarestoredininternalflashmemory(8MB).Bothmeasuringtransducers(U)MT550and(U)MT540measurebasicparameters(U,I,P)verypreciselywithaccuracyclass0.2accordingtotheIECEN60688standard.
InputrangewidthenablesmeasurementofallbasicACvoltageorcurrent.ThetransducergeneratesandacceptsdifferentI/Osignals.Ananalogueoutputsignalisproportionaltomeasurandandisintendedforthecontrolofanalogueanddigitaldevices.Apulseoutputisintendedforsendingdatatodevicesforcheckingandsupervisingconsumedenergy.
Besidesthefeatureslistedinthechapter“FamilyofMeasuringTransducersMT5x0/UMT5x0-comparisonandcommoncharacteristics”,thetransduceralsohasotherfeatures:•Harmonicanalysisofphase,phase-to-phasevoltagesandcurrentsuptothe31rdharmonic•32adjustablealarms•Recordingupto32measurandsand32alarmsintheinternalmemory(8MBflash,onlyMT/UMT550).
Dimensionaldrawingsonpage81.Connectiondiagramsonpages94-97.Softwareonpages32-35.
MT550/UMT550-TRANSDUCER&RECORDER,MT540/UMT540-MULTIFUNCTIONTRANSDUCER
MeasuringTransducers
19
USB 2.0
RS232/485
RS4851 2 32
MODBUS TCP
ETHERNET
Features:•Remoteapplicationformeasuringtransducers(U)MT560,(U)MT550,(U)MT540•Networkconnectionforupto32transducers•RS485communication•Universalpowersupply48-276VAC,20-300VDC•GraphicalLCD128x64dots•Multilingualsupport
Remotedisplay is veryuseful for aquicksurveyof allmeasured parameters or for setting up the (U)MT5xxmeasuringtransducerswithoutthePC.Navigationkeysand graphical LCD display enable remote applicationandremotedisplaysettings.BychoosingdifferentRD500 target communication addresses it is possible totrackmeasurementsandchangesettingsforupto32(U)MT5x0measuringtransducers.
RD500-REMOTEDISPLAYFORMEASURINGTRANSDUCERSMT5x0/UMT5x0
Dimensionaldrawingsonpage81.
MeasuringTransducers
20
MT510/UMT510-POWERTRANSDUCER
(U)MT510isintendedformeasuringandmonitoringsingle-phaseelectricalpowernetwork.Voltageandcurrentinputsareelectricallyisolatedfromthesystembymeansofhighlyresistiveinputchainandcurrenttransformerrespectively.ItmeasurestrueRMSvaluesbymeansoffastsamplingofvoltageandcurrentsignals,whichmakesinstrumentssuit-ableforacquisitionoftransientevents.Abuilt-inmicrocontrollercalculatesmeasurands(voltage,current,frequency,energy,power,powerfactor,powerangles,THDU,THDI,MD)fromthemeasuredsignals.
Features•Measurementsofinstantaneousvaluesofallsinglephasevalues;U,I,P,Q,S,f,ϕ,energy,THDU,THDI,MD•Poweraccuracyclass0.2•16adjustablealarms•Widefrequencyrangefrom16Hzto400Hz•RS232/RS485communicationupto115,200bit/sorUSBcommunicationorEthernetandUSB communicationsimultaneously•MODBUScommunicationprotocol•Upto2inputsoroutputs(analogueoutputs,digitalinputs,alarm(digital)outputs,pulseoutputs)•Universalpowersupply(twovoltageranges)•Automaticrangeofnominalcurrentandvoltage(max.12.5Aand600VL-N)•HousingforaDINrailmounting•User-friendlyPCMiQensoftware
Dimensionaldrawingsonpage81.Connectiondiagramsonpages98.Softwareonpages32-35.
MeasuringTransducers
21
MT511/UMT511-POWERTRANSDUCER&RECORDER
(U)MT511isintendedformeasuringandmonitoringsingle-phaseelectricalpowernetwork.Voltageandcurrentinputsareelectricallyisolatedfromthesystembymeansofhighlyresistiveinputchainandcurrenttransformer,respectively.ItmeasurestrueRMSvaluesbymeansoffastsamplingofvoltageandcurrentsignals,whichmakesinstrumentssuit-ableforacquisitionoftransientevents.Abuilt-inmicrocontrollercalculatesmeasurands(voltage,current,frequency,energy,power,powerfactor,powerangles,THDU,THDI,MD)fromthemeasuredsignals.
Features•Measurementsofinstantaneousvaluesofallsinglephasevalues;U,I,P,Q,S,f, ϕ,energy,THDU,THDI,MD•Poweraccuracyclass0.2•Recordingofupto8measurandsand16alarmsintheinternalmemory(8MBflash)•16adjustablealarms•Widefrequencyrangefrom16Hzto400Hz•RS232/RS485communicationupto115,200bit/sorUSBcommunicationorEthernetandUSB communicationsimultaneously•MODBUScommunicationprotocol•Upto2inputsoroutputs(analogueoutputs,digitalinputs,alarm(digital)outputs,pulseoutputs)•Universalpowersupply(twovoltageranges)•Automaticrangeofnominalcurrentandvoltage(max.12.5Aand600VL-N)•HousingforaDINrailmounting•User-friendlyPCMiQensoftware
Dimensionaldrawingsonpage81.Connectiondiagramsonpages98.Softwareonpages32-35.
MeasuringTransducers
22
(U)MT516isintendedformeasuringandmonitoringsingle-phaseelectricalpowernetwork.Voltageinputiselectricallyisolatedfromthesystembymeansofhighlyresistive inputchain. ItmeasurestrueRMSvoltagevaluebymeansoffastsamplingofvoltagesignals,whichmakesinstrumentssuitableforacquisitionoftransientevents.Abuilt-inmicro-controllercalculatesmeasurands(voltage, frequency,THDU) fromthemeasuredsignals.MeasurandscanthenbeconvertedintoloadindependentDCcurrentorvoltagewhichisproportionaltothetrueRMSmeasuredvalueforthepurposeofregulatinganalogueand/ordigitaldevices.
Features•MeasurementsoftrueRMSvoltage,frequencyTHDU•Highaccuracyclass0.2(IEC-688)•Widefrequencyrangefrom16Hzto400Hz•16adjustablealarms•RS232/RS485communicationupto115,200bit/sorUSBcommunicationorEthernetandUSB communicationsimultaneously•MODBUScommunicationprotocol•Upto2inputsoroutputs(analogueoutputs,digitalinputs,alarmoutputs,digitaloutputs)•Universalpowersupply(twovoltageranges)•Automaticrangeofnominalvoltage(max.600VL-N)•HousingforaDINrailmounting•User-friendlyPCMiQensoftware
Dimensionaldrawingsonpage81.Connectiondiagramsonpages98.Softwareonpages32-35.
MT516/UMT516-VOLTAGETRANSDUCER
MeasuringTransducers
23
(U)MT518isintendedformeasuringandmonitoringsingle-phaseelectricalpowernetwork.Inputcurrentiselectricallyisolatedfromthesystembymeansofcurrenttransformer.(U)MT518measurestrueRMScurrentvaluebymeansoffastsamplingofcurrentsignals,whichmakesinstrumentssuitableforacquisitionoftransientevents.Abuilt-inmicro-controller calculatesmeasurands (current, frequency,THD I) from themeasuredsignals.Measurandscan thenbeconvertedintoloadindependentDCcurrentorvoltagewhichisproportionaltothetrueRMSmeasuredvalueforthepurposeofregulatinganalogueand/ordigitaldevices.
Features•MeasurementsoftrueRMScurrent,frequency,THDI•Highaccuracyclass0.2(IEC-688)•Widefrequencyrangefrom16Hzto400Hz•16adjustablealarms•RS232/RS485communicationupto115,200bit/sorUSBcommunicationorEthernetandUSB communicationsimultaneously•MODBUScommunicationprotocol•Upto2inputsoroutputs(analogueoutputs,digitalinputs,alarmoutputs,digitaloutputs)•Universalpowersupply(twovoltageranges)•Automaticrangeofnominalcurrent(max.12.5A)•HousingforaDINrailmounting•User-friendlyPCMiQensoftware
Dimensionaldrawingsonpage81.Connectiondiagramsonpages98.Softwareonpages32-35.
MT518/UMT518-CURRENTTRANSDUCER
MeasuringTransducers
24
MT406 is intended for measuring and monitoring voltage in electrical power network. Voltage input is electricallyinsulatedfromthesystembymeansofvoltagetransformer.Thesignal is rectified,smoothedandamplified intoanindependentDCcurrentoutput.
APPLICATION
TheMT406voltagetransducerisusedforapermanentmonitoringofasingle-phasevoltagevalue.PLCs,PCs,micro-processorcontrol,indicators,alarmsunitsetc.canbeoperatedbytheoutputsignal.Voltageinputcanbeconnectedeitherdirectlytolow-voltagenetworkorshallbeconnectedtonetworkviaacorrespondingvoltagetransformer(withstandard100Voutput).
Features:• SinusoidalACvoltagemeasurements• Voltagerangemeasurementsupto500VL-N• Galvanicinsulationbetweeninputandoutput• Accuracyclass0.5• Selfpowered• HousingforDINrailmounting
Dimensionaldrawingsonpage81.Connectiondiagramsonpages99.
MT406-ACVOLTAGESELFPOWEREDTRANSDUCER
MeasuringTransducers
25
MT408-ACCURRENTSELFPOWEREDTRANSDUCER
MT408isintendedformeasuringandmonitoringsingle-phaseelectricalpowernetwork.Currentinputiselectricallyinsulatedfromthesystembymeansofcurrenttransformer.Thesignal isrectified,smoothedandamplified intoanindependentDCcurrentoutput.
APPLICATION
TheMT408currenttransducerisusedforapermanentmonitoringofasingle-phasecurrentvalue.PLCs,PCs,micro-processorcontrol,indicators,alarmsunitsetc.canbeoperatedbytheoutputsignal.Currentinputcanbeconnectedeitherdirectlytolow-voltagenetworkorshallbeconnectedtonetworkviaacorrespondingcurrenttransformer(withstandard1Aor5Aoutput).
Features:• SinusoidalACcurrentmeasurements• Currentrangemeasurementsupto6A• Galvanicinsulationbetweeninputandoutput• Accuracyclass0.5• Selfpowered• HousingforDINrailmounting
Dimensionaldrawingsonpage81.Connectiondiagramsonpages99.
MeasuringTransducers
26
MT416-PROGRAMMABLEACVOLTAGETRANSDUCER
APPLICATION
TheMT416voltagetransducerisusedforapermanentmonitoringofasingle-phasevoltageandfrequencyvalues.MT416 isdeliveredconfigured todefault values.Subsequentcustomerconfiguration ispossiblewithuser friendlysettingsoftwareMiQen.MT416supportsstandardserialRS232/485withspeedupto115200bps.USB2.0canbeusedforafastset-upormemoryacquisition(afterinstallationUSBconnectionisnotpossibleanymore).AdditionalUSB2.0interfacecanonlybeusedforafastset-upwithoutneedforauxiliarypowersupply.ThisinterfaceisNOTgalvanically isolated from analogue output and can be used ONLY unconnected to aux. supply and measuringinputs.
Features:• TrueRMSACvoltagemeasurements• Voltageautorangemeasurementsupto600VL-N• Frequencymeasurementrange16-400Hz• ACoruniversalwideauxiliarypowersupplyrange24-300Vdc,40-276Vac• Accuracyclass0.5(EN60688)• Serial(RS232orRS485)communication• Sophisticatedanalogueoutput;2voltageand4currentranges,non-linearcharacteristics…• SimpleUSBsettingwithoutauxiliarypowersupply PROPERTIES • MeasurementsoftrueRMSvoltage,frequencyTHDUandMD• Accuracyclass0.5(EN60688)• Inputfrequencyrange:50/60Hz,400Hz• RS232/RS485communicationupto115,200bit/sandUSB2.0communication• MODBUScommunicationprotocol• Universalpowersupplyortransformerpowersupply• Automaticrange(max.600VL-N)• HousingforDINrailmounting• User-friendlyPCMiQensoftware
MT416isintendedformeasuringandmonitoringsingle-phase electrical power network. Voltageinput is electrically isolated from the system bymeans of voltage transformer. It measures trueRMSvoltagevaluebymeansoffastsamplingofvoltage signals, which makes instruments suit-ableforacquisitionoftransientevents.Abuilt-inmicrocontroller calculates measurands (voltage,frequency,THDU,MD)fromthemeasuredsig-nals. Measurands (U, f) can be then convertedinto load independent DC current or voltagewhichisproportionaltothetrueRMSmeasuredvalue for thepurpose of regulationof analogueand/ordigitaldevices.
Dimensionaldrawingsonpage81.Connectiondiagramsonpages99.Softwareonpages32-35.
MeasuringTransducers
27
MT418-PROGRAMMABLEACCURRENTTRANSDUCER
APPLICATION TheMT418current transducer isused forapermanentmonitoringofasingle-phasecurrentand frequencyvalues.MT418isdeliveredconfiguredtodefaultvalues.Subsequentcustomerconfigurationispossiblewithuserfriendlyset-tingsoftwareMiQen.MT418supportsstandardserialRS232/485withspeedupto115200bps.USB2.0canbeusedforafastset-upormemoryacquisition(afterinstallationUSBconnectionisnotpossibleanymore).AdditionalUSB2.0interfacecanonlybeusedforafastset-upwithoutneedforauxiliarypowersupply.ThisinterfaceisNOTgalvanicallyisolatedfromanalogueoutputandcanbeusedONLYunconnectedtoaux.supplyandmeasuringinputs.
Features:• TrueRMSACcurrentmeasurements• Currentautorangemeasurementsupto12A• Frequencymeasurementrange16-400Hz• ACoruniversalwideauxiliarypowersupplyrange24-300Vdc,40-276Vac• Accuracyclass0.5(EN60688)• Serial(RS232orRS485)communication• Sophisticatedanalogueoutput;2voltageand4currentranges,non-linearcharacteristics…• SimpleUSBsettingwithoutauxiliarypowersupply PROPERTIES • MeasurementsoftrueRMScurrent,frequency,THDIandMD• Accuracyclass0.5(EN60688)• Inputfrequencyrange:50/60Hz,400Hz• RS232/RS485communicationupto115,200bit/sandUSB2.0communication• MODBUScommunicationprotocol• Universalpowersupplyortransformerpowersupply• Automaticrange(max.12A)• HousingforDINrailmounting• User-friendlyPCMiQensoftware
MT418 is intended for measuring and monitoringsingle-phaseelectricalpowernetwork.Currentinputiselectrically isolatedfromthesystembymeansofcurrent transformer. It measures true RMS currentvaluebymeansof fastsamplingofcurrentsignals,whichmakes instrumentssuitable foracquisitionoftransientevents.Abuilt-inmicrocontrollercalculatesmeasurands (current, frequency,THDU,MD) fromthemeasuredsignals.Measurands(I,f)canbethenconvertedintoloadindependentDCcurrentorvolt-agewhichisproportionaltothetrueRMSmeasuredvalueforthepurposeofregulationofanalogueand/ordigitaldevices.
Dimensionaldrawingsonpage81.Connectiondiagramsonpages99.Softwareonpages32-35.
MeasuringTransducers
28
MT440-MULTIFUNCTIONALTRANSDUCER
APPLICATION TheMT440multifunctiontransducerisusedformeasuringandmonitoringofallsingle-phaseorthree-phasevalues.Widerangeofvarious I/OmodulesmakesMT440aperfectchoice fornumerousapplications.MT440 isdeliveredun-configuredforcustomerconfigurationwithuserfriendlysettingsoftwareMiQen.MT440supportsstandardserialcommunicationRS232orRS485withspeedupto115200baud,whichisperfectforsimpleapplicationsandserialbusinterfacing.AdditionalUSB2.0interfacecanonlybeusedforafastset-upwithoutneedforauxiliarypowersup-ply.ThisinterfaceisNOTgalvanicallyisolatedfrompowerinputs(aux.supplyandmeasurementinputs)andcanbeusedONLYunconnectedtopowerinputs.
Features:• Voltageandcurrentautorangemeasurementsupto600V,12.5A• Universalwideauxiliarypowersupplyrange24-300Vdc,40-276Vac• Poweraccuracyclass0.5(EN60688)• UptofourI/Omodules(analogueout,pulseout,alarmout,generalpurposedigitalout)• Sophisticatedanalogueout;2voltageand4currentranges,non-linearcharacteristics…• SimpleUSBsettingwithoutauxiliarypowersupply PROPERTIES • Measurementsofinstantaneousvaluesofmorethan50quantities (V,A,kW,kVA,kvar,kWh,kvarh,PF,Hz,MDthermal,THD,etc)• Poweraccuracyclass0.5• 16adjustablealarms• Inputfrequency:50/60Hz,400Hz• Serialcommunication(RS232orRS485upto115,200bit/s)andUSB2.0• MODBUScommunicationprotocol• Upto4I/O(analogueoutputs,alarmoutputs,pulseoutputs,generalpurposerelayoutput, generalpurposesolid-stateoutput)• Singlewideauxiliarypowersupplyrange24-300Vdc,40-276Vac• Automaticrangeofcurrentandvoltage(max.12.5Aand600VL-N)• HousingforDINrailmounting• User-friendlysettingsoftware,MiQen
MT440 are intended for measuring and monitor-ing single-phase or three-phase electrical powernetwork. They measure RMS value by means offastsamplingofvoltageandcurrentsignals,whichmakes instruments suitable for acquisition of tran-sient events. A built-in microcontroller calculatesmeasurands (voltage, current, frequency, energy,power,powerfactor,THDphaseangles,etc.) fromthemeasuredsignals.
Dimensionaldrawingsonpage81.Connectiondiagramsonpages100.Softwareonpages32-35.
MeasuringTransducers
29
MI4xx-MEASURINGTRANSDUCER
• ResistanceMI452• DCvoltageMI456• DCcurrentMI458• TemperaturewithPt100MI450• TAPpositionMI454
Type/Description Accuracyclass Inputs Housingwidth(a)
MI452TemperaturewithPt100,Pt1000,Ni100 0.5 2-wire,3-wire,4-wire 45mm
MI452Resistance0.5
R=0…10Ω…50kΩR=0…100Ω…500kΩ
45mm
MI454TAPposition0.5
100Ω…50kΩ1000Ω…500kΩ
45mm
MI456DCvoltage0.5
U=50mV…1VDCU=1V…50VDC
U=50V…400VDC45mm
MI458DCcurrent0.5
I=1…10mADCI=10…100mADC
45mm
ACauxiliarypowersupply:57,63.5,100,110,230,400,500V
Options:RS232orRS485serialcommunicationportUniversalaux.powersupplyforDC&AC24…300VDC/40…276VAC
*Powersupplyfromameasuringcircuitonly.Communicationportandaux.powersupplyarenotavailable.Output0.5mA,10mA,20mA.
Dimensionaldrawingsonpage81.Connectiondiagramsonpages101.Softwareonpages32-35.
30
Communicators
PLUG AND PLAY “OUT-OF-THE-BOX” DEVICE FOR MONITORING/RECORDING/CONVERTING/ALERTING DATA
USE• Forbuildingsmanagersandowners,utility companies,AMRsolutions,EMsolutions providers.• PCCI (Point-of-Common-Coupling Interface) for integrationofSmartGridsandDistributeddEnergy Resources.PCCIisusedforasimple,standardized connection of micro and small generation of electricity from distributed resources to the distri- butionnetwork.PCCIfunctionalitiesincluderemote monitoring and control, communication with the controlcenter,powerqualitymonitoringaccording toEN50160,possibilityof controllingcompensa- tiondevices,variousprotection functions (voltage, frequency,islandoperation,etc.).• Concentrator/Converter - used as protocol converter between Iskra-MIS products and other devices. IEC61850module in server configuration alreadysupported,DNP3slavemoduleinadevel- opmentstage.
• LiSa-MiBoxisabasicmoduleofaLiSasystem. LiSaisasystemfordetectionofdifferenterrorson middle-voltage overhead transmission lines and transformerstations.FEATURES:
•Embeddedplatformwithmiddlerangerequirements•PreinstalledMiSmartapplication•Theunit is independent fromexternal resourceswithall thesystem’scomponentsalready included(measuring system,database,set-upapplicationandmonitoringapplication)•Formonitoring/collectingdatafrommeasuringdevices,alerthandling,controllinganddatamanagement•administrationoftheMiBoxanddataanalysis/managementissupportedalsooverawebinterface•IP-basednetwork(Ethernet,GPRS/UMTS,optionallyWiFi) forprimaryuseandwith localcommunication(USB, serial)forsecondaryuse•Functionofprotocolconversion•Industrialtemperaturerangefrom-25°cto+50°c
BENEFITS:
•Extensionsoftheexistingsystemsandapplicationspossible•Upgradepossibilities(localandremote)•Costbenefitsduetothepartialupgrades•Openplatformwithcustomeradd-onextensions•Supportforstandardcommunicationprotocols(IEC61850,OPC,...)
MiBOX
Dimensionaldrawingsonpage81.Connectiondiagramsonpages90,91.Softwareonpages31-34.
MeasuringCentres
31
MiBOX
32
Software
MIQEN
MiQensoftwareisatoolforcompletemonitoringofthemeasuringinstruments.RS485/RS232orTCP/IPcommunica-tionisusedforconnectionwithaPC.Auser-friendlyinterfaceconsistsoffivesegments:devicemanagement,countersettings,real-timemeasurements,dataanalysesandprogramsupdating.
Device managamentAseasyaspossible.Justselectthedeviceinafavouritesline.
Usethenetworkexplorertosetandexplorethedevicesnetwork.Communicationparametersofalldevicesandtheiraddressesinnetworkcanbeeasilyset.
Instrument settingMultiRegisterEdittechnologyassuresasimplemodificationofsettingsthatareorganisedintreestructures.Besidessettingstransferintotheinstrument, storing and reading from the setting filesandMMCsarealsoavailable.
Real-time measurementAllsupportedmeasurementscanbeseeninrealtimeinatableform,whileharmonicsandtheirtime-recon-structedsignalsarealsodisplayedgraphically.Forfur-therprocessingoftheresultsofmeasurements,copy-ingviaaclipboardintostandardWindowsformatsissupported.
33
Software
MIQEN
Data analysisAnalysiscanbeperformedfor the instrumentswithabuilt-inmemory.Recordedquantitiescanbemonitoredin a tabular or graphical form, events that triggeredalarmscanbeanalysedorareportonqualityofsupplyvoltagecanbemade.AlldatacanbeexportedtotheAccessdatabase,Excelworksheetsortextfiles.
Programs updatingAlwaysusethelatestversionofsoftware,bothMiQenandsoftwareintheinstrument.Theprogramautomati-cally informs you on available upgrades that can betransferredfromthewebsiteandusedforupgrading.
System requirements:Windows 98, 2000, Millennium, XP, NT4.0, 100 MB capacity on a hard disc, VGA Screen, 64 MB RAM, CD drive,RS232communicationport
There are two versions of MIQEN software:•standard edition -allfunctionsavailableexceptfordataanalysis,freeofcharge•professional edition-allfunctionsavailableforinstallation,youhavetobuyaCDkey
34
MiSMART
MiSMART
MiSMART isanintegratedsoftwareplatformforcentralizedacquisition,storageandrepresentationofdatacapturedbydistributedmeasurementdevices.Itenablesmonitoringofalargenumberofmeteringpoints.Allcaptureddatacanberemotelyaccessedbyasimplewebbrowser.Easyintegrationofthirdpartytoolsanddataanalysissoftwaremakeithighlyadaptabletoanyrangeofcustomizeduserapplications.Themostcommonfieldsofimplementationareenergymanagement,monitoringofenergyproduction,transformerstationmonitoring,automatedmeterreadingetc.
Customer benefits•completeturn-keysolutionforremotedataacquisitionandmanagement•integratedtoolsfordatamanagement•highlycustomizedforIskraMISmeasurementdevicesforefficientsystemoperation•utilizationofwiderangeofcommunicationtechnologiesforbestnetworkconfiguration(serial,ethernet,GPRS,SMS, lowpowerradioetc.)•immediatealarmingandnotification•reliableoff-loaddatacollection,basedondataredundancy•easyintegrationofthirdpartytoolsandsoftware
MiSMART PLAtform:•MiSMARTdatacollector•MiSMART database•MiSMARTwebserver
Windowsbasedplatformwiththree-tierarchitectureforefficientplatformmanagement.Itutilizesinnovativepushdatacollectionmechanismcombinedwithadvancedinstrumetswithbuiltinmemoryfordataredundancyresultinginhighdatacollectionreliability.
MiSMART DATACOLLECTOR:•capturesmeasurements,alarms,settingsandpowerqualityreports•realtimealarmmanagement•automatictimesynchronizationofdevices•possiblecompressedbinarydatatransfertominimizenetworkload•configurabledataresolution
MiSMARTDATABASE:•storesmeasurements,alarms,settingsandpowerqualityreports•implementedonMSSQLdatabase•centralizedordistributeddatastorage•standarddatabaseinterfacesenableeasyaccesstoexternalthirdpartyapplications
MiSMARTWEBSERVER:•multiclientconnections•multiusermanagement•graphicalandnumericaldatarepresentation•webconfigurationandactivitymonitor•monitoringofmeasurements,alarmsandpowerqualityreportsAuserclientcanconnecttotheMiSMARTWebServerwithastandardinternetbrowser.
35
MiSMART
MiSMART
MiSMARTDatabase
MiSMART Web
Server
MiSMARTdatacollector
MiSMARTClients
MiSMARTPLATFORM
LANINTERNET
VPN
CommunicationAdapters
36
MI480isadevicewithabuilt-inGPRSmodeminterfaceforcollectingandsendingmeasurementsfromtheconnectedinstrumentstothewebportal.Itisidealforcontrollingdistantobjects,suchaspowerplants,pumps,transformersta-tions,measuringstations,temperaturemonitoring…).
DataarecollectedintheMI480internalmemoryandsentinpacketsviatheGPRScommunicationtothewebportal.Alarmscanbeimmediatelyforwardedtovariousmobilephonenumbers.
Mainfeaturesare:•AlarmsviaanSMSmessagetoamobilephone•TrendalarmsviaanSMSmessagetoamobilephone•DataoninstantaneousmeasurementsviaSMS•Sendingmeasurementpackagestotheserverforfurtherprocessing•Surveyofallmeasurementsviaawebportal•Allsettingsareaccessibleviaawebportal
Due to its characteristics, MI 480 is an ideal instrument to be used in systems where permanent or periodicalmonitoring,storingthemeasurementsformomentaryandlateranalysisandprocessingarerequired.Thesystemcanbeadaptedtotheneedsandrequirementsoftheindividualuserorsystemtowhichitisbuilt-in.
Dimensionaldrawingsonpage81.Connectiondiagramsonpages101.
MI480-GSMDEVICEFORREMOTECONTROL
CommunicationAdapters
37
RS485
RS485
RS485 communicationRS485 communication enables connection of up to 32 instruments with one MI 480 device. It is limited to themaximumconnectionlengthof1000m.ConnectionoftheRS485communicationisdescribedintablesandfiguresbelow.
Contacts for RS485 communication
MI480 RS485 Measuringcentres Measuringtransducers
A(21) DATA+ A(8) A(21)
B(23) DATA- B(7) B(23)
MI480 MI485RS485 MI485RS232 Measuringcentres Measuringtransducers
A(21) A(21) Rx(24) Rx(3) Rx(24)
GND(25) GND(5) GND(25)
B(23) B(23) Tx(26) Tx(2) Tx(26)
Contacts for connection via MI485 interface
Web portalThewebportalistheuser'saccesspointforsettingandanalysingcollecteddata.Itisusedinaremotecontrolsystemforasmallpowerstationandasystemfordetectingcuttransmissionlinesandcontrollingtransformerstationdefects.Forbetterunderstandingofinformationflowseethefigurebelow.
Connection of the instrument via MI 485 interface
MI480-GSMDEVICEFORREMOTECONTROL
Connection of modem interface
RS485
CommunicationAdapters
38
MI485canbeusedforintegratingdeviceswithRS232communicationintoRS485networkorasaconnectionbetweenRS485networkandacontroldevice(PC,PLC,etc.)
TheMI485communicationadapterisusedforconvert-ingRS485signaltoRS232signalandviceversa.Signalsareelectricallyisolated.Nosettingsarerequiredandthedeviceisreadyforuse.Communicationspeedisupto115,200bps.
Connections: •Auxiliarysupply-connectedwithconnectionterminals13,14•RS232communication,max.length3m
•RS485communication,upto32devices,alineshouldbeterminatedwitha120Ωresistor.
Dimensionaldrawingsonpage81.Connectiondiagramsonpages101.
MI485-RS232/RS485INTERFACE
MI485 Computer-DB9
Tx(26) Rx(2)
Rx(24) Tx(3)
GND(25) GND(5)
MI485 RS485-instruments
A(21) DATA+
B(23) DATA-
CommunicationAdapters
39
The MI 486, MI 488 communication adapters areused for connecting the instruments with RS232 orRS485communicationon theEthernetnetwork.The instru-ments are connected to the computer through theEthernet network. Signals are electrically isolated.Dataarereadfromthe instrumentsthroughinterfac-es.Communicationspeedisupto115,200bps.
MI486 Computer-DB9
Tx(26) Tx(2)
Rx(24) Rx(3)
GND(25) GND(5)
Connections:•Auxiliarysupply-connectedwithconnectionterminals13,14•Ethernetconnection-connectedwith10/100RJ45connectionterminal•RS232communication(forMI486),max.length3m
MI488 InstrumentswithRS485
A(21) DATA+
B(23) DATA-
•RS485communication(forMI488),upto32devices,alineshouldbeterminatedwitha120Ωresistor.
Dimensionaldrawingsonpage81.Connectiondiagramsonpages101.
MI486−RS232INTERFACE-TCP/IPMI488−RS485INTERFACE-TCP/IP
DigitalMeters
40
DIGITALMETERSWITHLEDDISPLAY
Digital meters with LED display enable fast andaccurate survey of electric quantities and areconvenient for industrial use as well as for theproduction and distribution of electric energy.TheyarepanelmountedandenablemeasurementofTRMSvaluesofelectricquantities.
Features:•TrueRMSmeasurements•LEDDisplayswith4or3digits•Measurementrangesfrom0...500Vand0...9999A•CTratioadjustmentforA-meters.../5A•CTratiofrom1…2000•MeasurementrangeforFrequencymeters20…500Hz.•Accuracy±1%(±0.2%forFrequencymeters)•Powersupply230VAC±20%,50/60Hz•Powerconsumption<3VA•Ambienttemperature:-5°C...+55°C
DigitalMeters
41
TypeDM 206
VoltmeterDM 208
AmmeterDM 306
VoltmeterDM 308
AmmeterDM 310
Multimeter
DM 202 Frequency
meter
DM 302 Frequency
meter
Frontframe(mm) 72x72 72x72 96x96 96x96 96x96 72x72 96x96
Display 3-digit 4-digit 3-digit 4-digit
Ammeter:3x4-digit
Voltmeter:3-digit
Frequencymeter:3-digit
3-digit 3-digit
Accuracy ±1%+2d ±1%+2d ±1%+2d ±1%+2d
Ammeter:±1%+2d
Voltmeter:±1%+2d
Frequencymeter:
±0,2%+2d
±0,2%+2d ±0,2%+2d
Measuringrange 0…500V 0…9999A 0…500V 0…9999A
Ammeter:0…9999A
VoltmeterL1,L2,L3:
0…500V
Frequencymeter:
30…70Hz
20…500Hz
(30…500VAC)
20…500Hz
(30…500VAC)
PowerSupply 230VAC±20%,50/60Hz
CTratio* - 1…2000 - 1…2000 1…2000 - -
Powerconsumption <3VA <3VA <3VA <3VA <=3W <=3W <=3W
Ambient
temperature-5°C…+55°C
Weight(kg) 0,23 0,23 0,28 0,28 0,29 0,26 0,30
*CTratio:1,2,3,4,5,6,8,10,12,15,20,25,30,40,50,60,80,100,120,150,160,200,250,300,320,360,400,500,600,700,800,900,100,1200,1400,1600,1800,2000.
Dimensionaldrawingsonpage83.
DIGITALMETERSWITHLEDDISPLAY
SynchronizationMeters
42
SQ0214
ZQ1207FQ1207
SQ0104,SQ0114,SQ0204,SQ0214,ZQ1207,FQ1207,ZQ1208,FQ1208
If you want to synchronise a generator and a bus barmanuallyorsemi-automatically,SQ0214andSQ0204are the right instruments for you. Our synchronizationmeters are very unique products, especially SQ 0214.Synchronizationmetersareintendedformanualorsemi-automaticsynchronizationoftwoelectric-energydistribution systems. SQ 0204, SQ 0214 synchro-scopesaretheinstrumentsformeasuringaphaseanglebetween two electric-energy distribution systems. TheSQ 0214 type also measures voltages and frequen-cies of both systems. On request, both types can beon request provided with a built-in relay output whichsignalisesiftheconditionsforsynchronizationhavebeenmet.ZQ1207orZQ1208two-systemfrequencymeterisusedformeasuringfrequencies intwonetworks.FQ1207orFQ1208doublevoltagemetermeasuresvolt-agesintwonetworks.
*ZQ1208andFQ1208forfrontframe144x144mmonrequest.**Otherratingsondemand
ShipversionmetersSQ0204,SQ0214,ZQ1207andFQ1207areavailableonrequest.
Twovoltages(Ugen,Ubb)andtwofrequencies(fgen,fbb)aredisplayedonLCDatSQ0214.Whenthedifferencebetweenfgenandfbbissmallerthan0.02Hz,UBUS,UGEN,FBUSandΔϕaredisplayed.
Bus-barvoltageUbbBus-barfrequencyfbb
GeneratorvoltageUgen Generatorfrequencyfgen
Bus-barvoltageUbbPhasedifferenceΔϕ
GeneratorvoltageUgen Bus-barfrequencyfbb
TYPE SQ0104 SQ0114 SQ0204 SQ0214 ZQ1207 ZQ1108 ZQ1208 FQ1207 FQ1108 FQ 1208
Frontframe(mm) 144x144 144x144 96x96 96x96 96x96 144x144 96x96* 96x96 144x144 96x96*
Cuttingformounting(mm) 138x138 138x138 92x92 92x92 92x92 138x138 92x92 92x92 138x138 92x92
Scalelength(mm) 360˚ 360˚ 360˚ 360˚ 92/72 2x50 2x50 92/72 2x50 2x50
Accuracyclass +/-1˚el. +/-1˚el. +/-1˚el. +/-1˚el. 0.5 0.5 0.5 1.5 1.5 1.5
RATING
100V,230V • • • • • • • • • •
400V • • • • • • • • • •
500V •** •** •** •** • • •
600V •** •** •** •** • •
Frequency • • • • •
Dimensionaldrawingsonpage73.Connectiondiagramsonpages103.
EnergyMeterswithPowerDisplay
43
WQ1217
WQ0217,WQ1217,WQ0207,WQ2207,WQ1247
WQ2207
Dimensionaldrawingsonpages77-79.Connectiondiagramsonpages93.
Energymetersdisplay instantaneouspower insingleandthree-phase systems with balanced or unbalanced load.Accuracy classes are 1 for energy measurement (EN61036),1.5forpowermeasurementand2.5powerfactormeasurement.
TYPE WQ 0217 WQ 1217 WQ 0207 WQ 2207 WQ 1247
Frontframe(mm) 96x96 96x96 96x96 96x96 96x96
Cuttingformounting(mm) 92x92 92x92 92x92 92x92 92x92
Scalelength(mm)/Numberofcounters -/1 -/2 95/1 125/1 -/2LCD
Voltageinput100V,110V,230V,400V,500V
Currentinput1A,5A
1b,1brSinglephasesystem • • • • •
3b,3brThree-phasethree-wirebalancedloadsystem • • • • •
3u,3urThree-phasethree-wirebalancedloadsystem • • • • •
4b,4brThree-phasefour-wirebalancedloadsystem • • •
4u,4urThree-phasefour-wireunbalancedloadsystem • • • • •
Option
Oneimpulseoutput • • • • •
Twoimpulseoutputs • • • • •
57V,110V,230V,400VACAuxiliarysupply • • • • •
HourMeters&PulseCounters
44
HK46 HK47 HK48,HK49 HK30
HK 46 HK 47 HK 48, HK 49 HK 30
Voltages
AC
24V,48V,60V,110V,120V,230V,240V,400V(±10%)
24V,48V,60V,110V,120V,230V,240V,400V(±10%)
24V,48V,60V,110V,120V,230V,240V,400V(±10%)
24V,48V,60V,110V,120V,230V,240V,400V(±10%)
Frequency 50Hz,60Hz 50Hz,60Hz 50Hz,60Hz 50Hz,60Hz
Countingrange 99999.99h 99999.99h 99999.99h 99999.99h
Numberofdigits 5integers,2decimals 5integers,2decimals 5integers,2decimals 5integers,2decimals
Operatingtemperature -25°C…+80°C -25°C…+80°C -25°C…+80°C -25°C…+70°C
Voltages
DC
6-30V,10-80V,110V(±10%)
6-30V,10-80V,110V(±10%)
6-30V,10-80V,110V(±10%)
6-12V,12-36V,36-80V,110V(±10%)
Countingrange 999999.9h 999999.9h 999999.9h 999999.9h
Numberofdigits 6integers,1decimal 6integers,1decimal 6integers,1decimal 6integers,1decimal
Operatingtemperature -20°C…+70°C -20°C…+70°C -20°C…+70°C -10°C…+55°C
HK 46 HK 47 HK 48, HK 49 HK 30
Protection IP40,frontside IP65,frontside IP40,frontside IP40,frontside
IP20,terminals IP00,terminals IP00,terminals IP20,terminals
Frontdimensions 48x48mm Ø58mm HK4872x72mm-HK4996x96mm 36x24mm
Adapterframes 52x52,55x55,72x72,Ø80mm Ø72mm,Ø80mm48x24,54x29,48x48,55x55,
Ø72x72mm52mminØ72mm
SpecialprotectionIP65,frontsideIP20,terminals
IP67,frontsideIP00,terminals
IP20,terminalsIP65frontside(transparenthousing),
IP00terminals
Approval UL UL UL CEmark,ULrecognized
Connection
plug6.3x0.8mmwithscrewplug6.3x0.8mm
screwterminals
plug6.3x0.8mmwithscrew
plug6.3x0.8mm screwterminalsplug6.3x0.8mmwithscrew
plug6.3x0.8mmscrewterminalsformountingD
HK 46 HK 47
Mounting Tip HK46CUTOUT HK47CUTOUT
aluminiumclamp A45x45mm,chamferedge
Ø51mm,45mmØ50mm
retainer G45x45mm,chamferedge
Ø51mm,45mm
DIN-rail D UL
snapfastener F
Antivibrationrubber,ø80mm
C Ø71mm
3-screwfrontmountingø72mm
H screwterminals Ø51mm
HK 48, HK 49 HK 30
Mounting TipHK48,HK49
CUTOUT
HK30CUTOUT
retainermount G 32x32mm
DINrail
toDINEN50022D Ø50mm
3-screwfrontmounting
Ø72mmH min.Ø50mm
twofixingscrewsHK48:68mmHK49:92mm
Hourmetersshowoperationtimeofmachines,equipmentandotherdevices.Whenyouneedaccurateinformationfortesting,maintenanceorwarrantypurposes,choosefromawiderangeofHKhourmetersproducedbyIskraMIS.ACapplications:businessmachines,controlpanels,compressors,generators,pumps,airconditioningDCapplications:gardenandfarmequipment,Gen-sets,constructionequipment.
HOURMETERSHK46,HK47,HK48,HK49,HK30
HourMeters&PulseCounters
45
SI63 MC703,MC723 SI64
Pulsecountersareusedtokeeprecordofrepetitiveoperations.Typical applications are event counting,quantitycounting,coinhandlingetc.
PULSECOUNTERSSI63,SI64,SI65,MC703&MC723
VERSION&MOUNTINGS
Type Frontdimensions Cutout
SI63.0rearscrewmounting;aluminiumhousing 30x18.9mm 30-18.9mm
SI63.1snapfastenermounting;transparentplastichousing 33.4x27.1mm 30.5x24.5mm
SI63.22-screwfrontsnapfastenermounting;transparentplastichousing 33.4x30mm min.30.5x22mm
SI64panelmountwithspringclipfastening 53x28mm 50x25mm
SI65DINhousingforpanelmountwithclip 48x24mm 45x22mm
MC703.xxAfrontreading,4pinsonthetop,PCBmount 25.2x13.5mm −
MC703.xxBtopreading,4pinsonthebottom,PCBmount 25.2x31mm −
MC703.xxCfrontreading,2pinsbehind,rearscrewmount 25.2x13.8mm 25.2x13.8mm
MC703.xxDfrontreading,wireleadbehind,rearscrewmount 25.2x13.8mm 25.2x13.8mm
MC723.xxCfrontreading,2pinsbehind,snapfastermount 30x20mm 26.5x13.8mm
MC723.xxDfrontreading,wireleadbehind,snapfastenermount 30x20mm 26.5x13.8mm
xx:60(6-digit)or70(7-digit)
Type SI63 SI64 SI65 MC703,MC723
totalizingcounterswithoutreset totalizerwithmanualresetminipulsecounterwithmanual
resettotalizingcounterswithoutreset
SupplyvoltageDC 6V,9V,12V,24V(±10%) 12V,24V(±10%) 12V,24V(±10%) 3V,5V,12V,24V(±10%)
SupplyvoltageAC 24/115/230V(±10%) 24/115/230V(±10%)
Display 6-digit 6-digit 5-digit 6-digitor7-digit
Countingrange 999999 999999 999999 999999or9999999
Power
consumption1W
approx.2W-VDC
approx.2.9VA-VAC
approx.0.5W-VDC
approx.0.75VA-VAC115VAC
approx.1.5VA-230VAC
approx.300mWat3and5VDC
approx.500mWat12and24VDC
approx.1.5VAC230VAC
Maxcountings
speed10pulses/sec.
25pulses/sec.-VDC
18pulses/sec.10pulses/sec. 10pulses/sec.
Protection
IP20
IP31-versionsCandD
IP65-versionsAandB
Connection wirelead200mm silverplatedroundpinsdia1.5mm 150mmflyingleadsAWG22wirelead140mmorsoldering
pinsφ 0.6mm
AnalogueMeters
46
EQ0207
EQ2207
Powermetersareelectronicmetersintendedformeasur-ingactiveorreactivepowerinsinglephaseorthree-phasenetworks,withbalancedorunbalancedload.Theaccuracyclassis1.5.Thescalevaluedependsonprimaryvaluesofcurrentandvoltage.Itisdefinedbythefollowingformulas:
Class1onrequest(onlyfor90degreedials).Self-consumptionofcurrentcircuitsapprox.0.1VAandvoltagecircuits0.2VA.*Max.voltageinputforEQ0307,EQ2307for3u,3b:150V/250VAC*Max.voltageinputforEQ0307,EQ2307for4u,4b,1b:230V/400VAC**Overloadsofshortdurationonpage230.ShipversionmetersEQ0207,EQ0107areavailableonrequest.
*UL-LIntheequationsUmeansphasevoltageatsinglephasenetworkandthree-phasefour-wirenetwork4uaswellasline-to-linevoltageatthree-phasethree-wire
network3u.Ratiobetweentheselectedfinalscalevalueandcalculatedpowershouldbewithinthelimitsfrom0.6to1.2atcosϕ=1orsinϕ=1.
ACTIVEORREACTIVEPOWERMETERS
TYPE EQ0307 EQ0207 EQ0107 EQ2307 EQ2207** EQ2107
Frontframe(mm) 72x72 96x96 144x144 72x72 96x96 144x144
Cuttingformounting(mm) 68x68 92x92 138x138 68x68 92x92 138x138
scale90° scale240°
Scalelength(mm) 63 95 135 113 135 220
Voltageinput*100V,110V,230V,400VCurrentinput1A,5A
1bsinglephasesystem • • • • • •
3bthree-phasethree-wiresystemwithbalancedload • • • • • •
3uthree-phasethree-wiresystemwithunbalancedload • • • •
4bthree-phasefour-wiresystemwithbalancedload • • • • • •
4uthree-phasefour-wiresystemwithunbalancedload • • • • •
Option
SeparatedACauxiliarysupply57V,63.5V,100V,230V,400V - • • - • •
activepower reactivepower
forsinglephasesystem 1b
IprimxUprimxcosϕ1br
IprimxUprimxsinϕ
forthree-phasesystem 3u
√3IprimxU*primxcosϕ
3ur
√3IprimxU*primxsinϕ
forthree-phasesystem 4u
3IprimxUprimxcosϕ4ur
3IprimxUprimxsinϕ
Dimensionaldrawingsonpages77-79.Connectiondiagramsonpages93.
AnalogueMeters
47
YQ0207
YQ2207
TYPE YQ0307 YQ0207 YQ0107 YQ2307 YQ2207 YQ2107
Frontframe(mm) 72x72 96x96 144x144 72x72 96x96 144x144
Cuttingformounting(mm) 68x68 92x92 138x138 68x68 92x92 138x138
scale90° scale240°
Scalelength(mm) 63 95 135 113 135 220
Voltageinput* 100V,110V,230V,400V,500V
Currentinput 1A,5A
MEASURINGRANGE0.5cap....1...0.5ind.
0.8cap...1...0.3ind.
1bSinglephasesystem • • • • • •
3bThree-phasethree-wirebalancedloadsystem • • • • • •
3uThree-phasethree-wireunbalancedloadsystem • • • • • •
4bThree-phasefour-wirebalancedloadsystem • • • • • •
4uThree-phasefour-wireunbalancedloadsystem • • • • • •
MEASURINGRANGEimport0.1cap.…1…0ind.0…1...0.1cap.export
Option:
SeparatedACauxiliarysupply
57V,63.5V,100V,110V,230V,400V- • • - • •
ShipversionmetersYQ0207areavailableonrequest.*Max.voltageinputforYQ0307,YQ2307for3u,3b:150V/250VAC*Max.voltageinputforYQ0307,YQ2307for4u,4b,1b:230V/400VAC
Dimensionaldrawingsonpages77-79.Connectiondiagramsonpages93.
SCALEOUTLOOK*Formeters:YQ2207,YQ2107
Power factor meters are intended for measurement ofpowerfactor(cosϕ)inathree-phasethree-wirenetworkwithabalancedloadofphasesorinasinglephasenetwork.Theaccuracyclassis1.5.
POWERFACTORMETERS
AnalogueMeters
48
ZQ0207
ZQ0507
Pointer frequency meters are intended for measurement of fre-quenciesintherangefrom45Hzto65Hz.Accuracyclassis0.5.
Otherratingsareavailableonrequest!ShipversionofthemetersZQ0307,ZQ0207,ZQ0107areavailableonrequest.
Two-systemfrequencymetersZQ1207,ZQ1208areonpage42.Dimensionaldrawingsareonpages77-79.
TYPE ZQ0507 ZQ0407 ZQ0307 ZQ0207 ZQ0107 ZQ2307 ZQ2207 ZQ2107
Frontframe(mm) 45x45 48x48 72x72 96x96 144x144 72x72 96x96 144x144
Cuttingformounting(mm) - 45x45 68x68 92x92 138x138 68x68 92x92 138x138
scale90° scale240°
Scalelength(mm) 41 41 65 95 135 101 135 220
MEASURING RANGE Voltage(V)
45…55Hz57,63,100,110,
230,400,500• • • • • • • •
55…65Hz57,63,100,110,230,400,500
• • • • • • • •
48…52Hz57,63,100,110,230,400,500
• • • • • • • •
45…65Hz57,63,100,110,
230,400,500• • • • • • • •
DETAIL ONLYFormeters:ZQ0x07
SCALES IN FULL-SIZEFormeters:ZQ2x07
POINTERFREQUENCYMETERS
AnalogueMeters
49
SCALES IN FULL-SIZEFormeters:ZQ2x07
ZQ0217
ZQ1217
Reedfrequencymetersareintendedformeasurementoffrequenciesintherangefrom45Hzto65Hz.Theaccuracyclassis0.5
Self-consumptionat110-220Vrangeis6…7mA/system.Atotherrangesitis3…4mA/system.ShipversionmetersZQ0317,ZQ0217andZQ0117areavailableonrequest.
Dimensionaldrawingsonpages77-79.
Two-systemsreedfrequencymetersareintendedformeasurementoftwofrequenciesinthesystemforsynchronisation.Accuracyclassis0.5.
Self-consumptionat110-230Vrangeis6…7mA/system.Atotherrangesitis3…4mA/system.ShipversionmetersZQ1217andZQ1117areavailableonrequest.
Dimensionaldrawingsonpages77-79.
REEDFREQUENCYMETERS
TYPE ZQ0317 ZQ0217 ZQ0117
Frontframe(mm) 72x72 96x96 144x144
Cuttingformounting(mm) 68x68 92x92 138x138
RATING Voltage(V) No.ofreeds
47…53Hz 100,110,230 13 • • •
400,500 • • •
57…63Hz 100,110,230 13 • • •
400,500 • • •
45…55Hz 100,110,230 21 • •
400,500 • •
55…65Hz 100,110,230 21 • •
400,500 • •
TYPE ZQ1217 ZQ1117
Frontframe(mm) 96x96 144x144
Cuttingformounting(mm) 92x92 138x138
RATING Voltage(V) No.ofreeds
2x47…53Hz 100,110,230 2x13 • •
400,500 • •
2x57…63Hz 100,110,230 2x13 • •
400,500 • •
2x45…55Hz 100,110,230 2x21 • •
400,500 • •
2x55…65Hz 100,110,230 2x21 • •
400,500 • •
AnalogueMeters
50
MI7350
MI 7350 can signal minimal and maximal setting limits (MINand MAX). The meter is provided with two output relays of600 VA switching power. Setting over or under the limits isdisplayed with a LED on the meter scale. DC or AC currentsor voltages, frequency and temperature can be signalised.
METERWITHLIMITCONTACT
TYPE MI7350
Frontframe(mm) 96x96
Cuttingformounting(mm) 92x92
Scalelength(mm) 95
MEASUREDQUANTITY
DCU
40…800mV •
1…60V •
100…600V •
ACU
100…800mV •
6…60V •
100…600V •
DCI
25…600μA •
1…60mA •
100…600mA •
1…5A •
ACI
1…6mA •
100…600mA •
1…5A •
8min.1.2A −
8min.6A −
ACIef
100…600mA •
1…5A •
1/2A,1.5/3A,2.5/5A •
4/8A,5/10A •
FREQUENCYf
45...55Hz •
48...52Hz •
45..65Hz •
55..65Hz •
THERMOCOUPLE(J,K,S)
0...250°C •
0...600°C •
0...1200°C •
0...1600°C •
TEMP.DEPENDENTRESISTORPT100(W)
-200...+800°CΔT...50°Cmin
•
•
•
•
Standardsupply230VAC;24V,48V,60V,110VDConrequest.
Dimensionaldrawingsonpages77-79.
AnalogueMeters
51
BQ0x07
BQ0507
Meterswithamovingcoilare intended formeasurementofdirectcurrentsorvoltages.Ameasuringsystemwithacore magnet is not sensitive to external electromagneticfields and is resistant to mechanical impacts and vibra-tions.Thescaleisentirelylinearandinterchangeable.Theaccuracyclassis1.5
AMMETERS:RATINGSandINTERNALRESISTANCES
BQ0x07 μA/Ω 40/5650,60/4710,100/2250,150/1950,250/990,400/350,600/150BQ2x07 μA/Ω100/5900,150/5100,250/4000,400/2400,500/1500,600/1300BQ0x07 mA/ Ω1/65,1.5/25,2.5/11,4/6,5/4,5,6/4,10/2,6,15/4,20/3,25/2,4,40/1.5,50/1.2,60/1,100/0.6,150/0.4,250/0.24, 400/0.15,600/0.1BQ2x07 mA/Ω 1/370,1.5/200,2.5/780,4/25,5/8.4,6/15,10/7,15/5,20/3.9mA:25,40,50,60,100,150,250,400,600 -voltagedroponterminalsapprox.60mVBQ0x07,BQ2x07A2):1, 1.5, 2.5, 4, 6, 10, 15, 25, 40, 60 -voltagedroponterminalsapprox.60mVxA/60mV2)
METERSFORDCVOLTAGEORCURRENTWITHMOVINGCOIL
TYPE BQ0507 BQ0407 BQ0307 BQ0207 BQ0107 BQ2507 BQ2407 BQ2307 BQ2207 BQ2107
Frontframe(mm) 45x45 48x48 72x72 96x96 144x144 45x45 48x48 72x72 96x96 144x144
Cuttingformounting(mm) - 45x45 68x68 92x92 138x138 - 45x45 68x68 92x92 138x138
scale90° scale240°
Scalelength(mm) 41 41 63 95 140 71 71 113 155 235
RATING
0-40μA...60μA - • • • • - - - - -
0-100μA...600μA • • • • • • • • • •
0-1mA...600mA • • • • • • • • • •
4...20mA3) • • • • • • • • • •
0-1A...6A • • • • • • • • • •
0-10A...25A - • • • • - • • • •
0-40A,60A - - • • • - - • • •
xA/60mV1) • • • • • • • • • •
0-100mV...600mV • • • • • • • • • •
0-1V...600V • • • • • • • • • •
AnalogueMeters
52
VOLTMETERS:RATINGSBQ0x07 mV2):60,100,150-5mAsystemBQ2x07 mV2):60,100,150,200,300-5mAsystemBQ0x07,BQ2x07 V:1,1.5,2.5,4,6,10,15,25,40,6000,150,250,400,600-1mAsystem -characteristicresistance1kΩ/V
1)Ameterforconnectiontoaseparateshunt,calibratedtoresistanceofconnectionterminals0.035Ω.2)Currentthroughameterapprox.5mA.3)Aversionwithelectricalzeropointsuppression.Aversionwithmechanicalzeropointsuppressionavailableonrequest.ShipmeterversionsofBQ0407BQ0307,BQ0207,BQ0107availableonrequest.
SCALES IN FULL-SIZE
Formeters: bQ 2x07 bQ 0x07 CQ 2x07 CQ 0x07 eQ 2207 eQ 0307, eQ 0207, eQ 0107 WQ 2207 WQ 0207 KQ 0207, KQ 0307 mi 7350
Specialmetersavailableonrequest;page67.Dimensionaldrawingsonpages77-79.
METERSFORDCVOLTAGEORCURRENTWITHMOVINGCOIL
AnalogueMeters
53
CQ 2207
CQ 0207
TAPPOSITIONMETERSWITHMOVINGCOIL
TAP meters with a moving coil are intended formeasurementoftappositionwithauxiliarysupplyAC voltage. The position indicator monitorstransformer tap position, hoist or valve positionetc. It employs a bridge system. 1-2 positionscanbeprovidedusing400Ω or50Ωper step.A measuring system with a core magnet is notsensitive to external electromagnetic fields. It isresistant to mechanical shocks and vibrationscomplying with EN 60051. The scale is entirelylinearandinterchangeable.
FEATURES:•Formeasurementoftapposition•Linearscale•Interchangeabledial•Resistanttomechanicalvibrationsandshocks•Protectivecoverforterminal
DIMENSIONSTYPE CQ2207 CQ0207
Frontframe(mm) 96X96 96x96
Cuttingformounting(mm) 92X92 92x92
Scale 240˚ 90˚
Scalelength(mm) 155 95
Dimensionaldrawingsonpage77.Connectiondiagramsonpage102.
AnalogueMeters
54
CQ0507
CQ0x07
TYPE CQ0507 CQ0407 CQ0307 CQ0207 CQ0107 CQ207* CQ2507 CQ2407 CQ2307 CQ2207** CQ2107
Frontframe(mm) 45x45 48x48 72x72 96x96 144x144 96x96 45x45 48x48 72x72 96x96 144x144
Cuttingformounting(mm) - 45x45 68x68 92x92 138x138 92x92 - 45x45 68x68 92x92 138x138
scale90° scale240°
Scalelength(mm) 41 41 63 95 140 95 71 71 113 155 235
RATING
0-100μA...600μA • • • • • - • • • • •
0-1mA...10mA • • • • • - • • • • •
xA/1A,xA/5A1)
(max.7.5A) • • • • • • • • • • •
0-2.5V...500V • • • • • - • • • • •
0-600V • • • • • - • • • • •
Meterswithamovingcoilanda rectifierare intendedformeasurementofACcurrentsorvoltagesinthefre-quency range from40Hz to65Hz (higher frequencyranges on request) where low consumption of themeter is required. Themetersmeasure amean valueof rectifiedcurrentor voltage.The scale is expressedin rms values at sine form of the measured quantity.Distortionordeviationfromthesineformformorethan1%entailsadditionalerrors.Thescale is interchange-able.Theaccuracyclassis1.5.
*CQ32074-stageselectorswitchisbuiltinthemeterformeasurementofcurrentinthreeindividualphases.Atcurrentswitch-overthecircuitisnotinterrupted.**Overloadsofshortdurationonpage104.
AMMETERS: RATINGS μA:100,150,250,400,500,600mA:1,1.5,2.5,4,5,6,10 Voltagedropapprox.1,5V A/Voltagedrop(V)x/1A−0.1V,x/5A−0.03V VOLTMETERS:RATINGSV:2.5,4,6,10,15,25,40,60,100,150,250,400,500,600-characteristicresistance1kΩ/V
1)Metersforconnectiontoacurrentmeasuringtransformer.Specialversionsofthemetersavailableonrequest;page67.2)ConnectiondiagramanddimensionaldrawingoftransformerforCQ0407,CQ2407onpage79andCQ3207onpage103.
Dimensionaldrawingsonpages77-79.
METERSFORACVOLTAGEORCURRENTWITHAMOVINGCOILANDARECTIFIER
AnalogueMeters
55
TYPE BN 0103 BN 0203 CN 0103 CN 0203
Frontframe(mm) 86x72 115x96 86x72 115x96
Cuttingformounting(mm) φ 65 φ 65 φ 65 φ 65
Scalelength(mm) 60 90 60 90
RATING
0-40μA...60μA • • - -
0-100μA...600μA • • • •
0-1mA...10mA • • • •
0-15mA...600mA • • - -
4...20mA3) • • - -
0-1A...6A • • - -
0-10A...25A • • - -
0-40A,60A • • - -
xA/1A,xA/5A2) - - • •
xA/60mV1) • • - -
0-100mV...600mV • • - -
0-1V...600V • • • •
1)Ameterforconnectiontoaseparateshunt.2)Ameterforconnectiontoacurrentmeasuringtransformer.3)Aversionwithelectricalzeropointsuppression.Aversionwithmechanicalzeropointsuppressionavailableonrequest.
Owing to a special form and available colours, BN and CNmeters are especially convenient for building into differentcontrol devices. The accuracy class is 1.5. The scale is notinterchangeable. BN meters are intended for DC currents orvoltages,andCNmetersforACcurrentsorvoltages.
AMMETERS: RATINGS & INTERNAL RESISTANCE
BN 0103, BN 0203
A/Ohm:40/5650,60/4710,100/2250,150/1950,250/990,400/350,600/150
A1):1,1.5,2.5,4,6,10,15,25,40,60
Voltagedroponterminalsapprox.60mV
CN 0103, CN 0203
μA:100,150,250,400,500,600
mA:1,1.5,2.5,4,5,6,10
Voltagedropapprox.1.5V
A/Voltagedrop(V)x/1A-0,1V,x/5A-0.03V
VOLTMETERS: RATINGS
BN 0103, BN 0203
mV1):60,100,150-5mAsystem
V:1,1.5,2.5,4,6,10,15,25,40,60,100,150,250,400,600-1mAsystem
-characteristicresistance1kOhm/V
CN 0103, CN 0203
V:2.5,4,6,10,15,25,40,60,100,150,250,400,500,600
-characteristicresistance1kOhm/V
1)Currentthroughameterapprox.5mA.
METERSFORDCANDACVOLTAGEORCURRENTWITHMOVINGCOIL
BN0103,CN0103
Dimensionaldrawingsonpage78.
AnalogueMeters
56
FQ0x07
FQ0507FN0201FN0103
METERSFORACVOLTAGEORCURRENTWITHMOVINGIRON
Meterswithamovingironareintendedformeas-urementofACcurrentsorvoltagesof frequen-cies from15Hz to100Hz.Theymeasure rmsvalues independentlyon thesignal formofcur-rentorvoltage.Theaccuracyclassis1.5.Asthebeginningofthescaleisnon-linear,readingfrom15% of rating onwards is possible. Ammeterswith rating for double, triple or even six-timevalue of rated current are available on request.Theoverloadrangeisextremelynon-linear.Thescaleisinterchangeable
TYPE FQ0507 FQ0407 FQ0307 FQ0207** FQ0107 FQ3307 FQ3207* FQ3107* FN0103* FN0201*
Frontframe 45x45 48x48 72x72 96x96 144x144 72x72 96x96 144x144 86x72 115x96
Cuttingformounting(mm) - 45x45 68x68 92x92 138x138 68x68 92x92 138x138 φ 65 φ 65
scale90°
Scalelenght(mm) 41 41 63 95 140 63 95 140 60 60
RATING
0-100mA...600mA • • • • • - - - • •
0-1A...10A • • • • • - - - • •
0-15A,25A • • • • • - - - • •
0-40A - - • • • - - - • •
0-60A - - • • • - - - • •
xA/1A,xA/5A • • • • • - - - • •
WITHOUTDIALxA/1A,xA/5A
• • • • • - - - - -
0-6V...600V • • • • • • • • • •
xV/100V,xV/110V • • • • • • • • • •
FQ3107,FQ3307areintendedformeasurmentofphaseandline-to-linevoltagesinthree-phasesystem.
Requiredphaseorline-to-linevoltageorcurrentisselectedwithaselectorswitch.
*Adialisnotinterchangeable**Overloadsofshortdurationonpage104.
AnalogueMeters
57
METERSFORACVOLTAGEORCURRENTWITHMOVINGIRON
AMMETERS:RATINGS
mA100,150,200,250,300,400,500,600A1,1.5,2.5,4,6,10,15,25,40,60AxA/1A,xA/5A-forconnectiontoacurrentmeasuringtransformer
VOLTMETERS:RATINGS
V6,10,15,25,40,60,100,150,250,300,400,500,600V.../100,.../110-forconnectiontoavoltagemeasuringtransformerSelf-consumptionfor:-ammeters:from0.3VAto1.2VAx/1A…0.4VAx/5A…0.7VA-voltmeters:from1.2VAto4VA
SCALES IN FULL SIZE FOR METERS: FQ 0x07
2timesoverload
3timesoverload
Dimensionaldrawingsonpages77-79.
ConnectiondiagramforFQ3107,FQ3207,FQ3307onpage103.
Metersforconnectiontoameasuringtransformerhavethefollowingstandardratings:1-1.2-1.5-2-2.5-3-4-5-6-7.5(8)and
decademultiples.
ShipversionmetersFQ0407,FQ0307,FQ0207,FQ0107availableonrequest.
Specialversionmetersavilableonrequest;onpage67.
AnalogueMeters
58
MQ0507MQ0207
150/5A-180A
Bimetal maximum current meters with a bimetalmeasuring system are intended for testing thermalloadoftransformers, cables, electricalmachines, etc. Theyindicate average rms current value in an 8 minutessettingperiod(onrequest15,20and30minutesforMQ0207andMQ0307).The accuracy class is 3. The meters are providedwithaninterchangeablescale.Meters96x96mmwithaprotectingtransformerarealsoavailableonrequest.
TYPE MQ0507 MQ0407 MQ0307 MQ0207 MQ0107
Frontframe(mm) 45x45 48x48 72x72 96x96 144x144
Cuttingformounting(mm) - 45x45 68x68 92x92 138x138
scale90°
Scalelength(mm 37 37 63 95 140
RATING
1.2A,xA/1A1)8min.* • • • • •
6A,xA/5A1)8min.* • • • • •
*Othersettingperiod(15,20and30minutes)onrequest.1)Theratingis20%higherthanthecurrenttransformerratio.Self-consumption:1.2VAat1.2A;2.2VAat6A.
Dimensionaldrawingsonpages77-79.
SCALE IN FULL-SIZEFormeters:MQ0207
BIMETALMAXIMUMCURRENTMETERS
AnalogueMeters
59
MQ0217
10/5A
Combinedbimetalmaximumcurrentmeters areprovidedwithabuilt-inbimetalsystemandasys-temwithamovingiron.Themetersareintendedfortestingmomentaryandthermalloadoftrans-formers,cables,electricalmachines,etc.Meters96x96mmwithaprotectingtransformerarealsoavailableonrequest.Theaccuracyclassforaveragermscurrentvalueis3,andformomentaryvalue1.5.Themetersareprovidedwithaninterchangeablescale.
SCALES IN FULL-SIZEFormeters:MQ0207
COMBINEDBIMETALMAXIMUMCURRENTMETERS
TYPE MQ 0317 MQ 0217 MQ 0117
Frontframe(mm) 72x72 96x96 144x144
Cuttingformounting(mm) 68x68 92x92 138x138
Scalelength(mm) 63/43 95/72 140/120
RATING
1.2AxA/1A*8min. • • •6AxA/5A*8min. • • •
*Ratingofaveragecurrentis20%higherthanthecurrenttransformerratio.
Themeterforamomentaryvaluecanindicateeither20%or100%overload.
Self-consumption:1.8VAat1.2A:2.8VAat6A.
Othersettingperiod(15.20and30minutes)onrequest.
Dimensionaldrawingsonpages77-79.
AnalogueMeters
60
SQ0201
KQ0x07
Aphasesequenceindicatorisintendedfordeter-mining phase sequences in a three-phase network,from200Vto500Vandfrom50Hzto60Hz.Theindicatorisprovidedwithtwobuilt-inglowlampsindicatingL1,L2,L3phasesequence.
Temperature meters are intended for connectiontovarious thermocouplesor temperaturedependantresistorswith thepossibilityofanalogueoutput.Theaccuracyclassis1.5.
PHASESEQUENCEINDICATORSQ0201ANDTEMPERATUREMETERS
TYPE KQ0307 KQ0307 KQ0207 KQ0207
Frontframe(mm) 72x72 72x72 96x96 96x96
Cuttingformounting(mm) 68x68 68x68 92x92 92x92
Scalelength(mm) 65 65 95 95
ANALOGUEOUTPUT - 0…10mARmax.=200Ω - 0…10mARmax.=200Ω
MEASURINGRANGE
ResistorprobePt100
+/-50°C • • • •
0…100°C • • • •
0…200°C • • • •
0…300°C • • • •
0…400°C • • • •
ThermocoupleJFe-CuNi
0…200°C • • • •
0…400°C • • • •
0…600°C • • • •
ThermocoupleKNiCr-Ni
0…600°C • • • •
0…800°C • • • •
0…1200°C • • • •
ThermocoupleSPtRh-Pt
0…1400°C • • • •
0…1600°C • • • •
Supply:230V∞+/-10%(50…60Hz) Otherthermocouplesonrequest.Onrequest:KQ0207,KQ0307 110V+/-10%(50…60Hz)
Dimensionaldrawingsonpages77-79.
PortableMeters
61
An analogue multiwattmeter is used for directmeasurementofDCpower,voltage,currentandactiveandreactivepower,voltage,current,cosϕand phase sequence in three-phase three-wiresystems with uniform load and active power,voltage, current, cosϕ in single phase ACsystems. The selection of current and voltageratings meets the majority of requirements forpowermeasurement in repair shops,productionpremises and in laboratories for fast and lessaccuratemeasurements.
MI7033ANALOGUEMULTIWATTMETER
Operationmode TDM(TimeDivisionMultiplication)
Voltageinputs 50V,100V,250V,500V
Currentinputs 0.25A,1A,5A,25A
Rating 12.5W...25,000W
Frequencyrange 10...16...65...400Hz
Accuracyclass power:1.5
voltage,current:2.5
cosϕ:5
Dimensions 110x181x62mm
Supply 2x9VIEC6F22
Weightwithpacking 700g
MI7033
PortableMeters
62
MI7065
Due to electric and constructional features theanalogue and digital universal meters are intendedfor a wide range of users. They are especiallyconvenient forrepairshops,electric, radioandelec-tronic professions as well as for the field work.Ratings are protected against overloads when themetersareconnectedto250V.
TYPE MI7054 MI7056 MI7065
Voltage
=
~
30V...600V100mV...
600V100mV-300V
30V…600V10V...600V
3V-300V
Current
=
~
0.3A...15A
50μA...1A
100μA-3A
0.3A...15A
3mA...3A
100μA-3A
Characteristicresistance=~
1.45kΩV 20kΩ/V 10MΩ
1.33kΩ/V 6.67kΩ/V 10MΩ
Numberofratings 15 24 25
Resistance Ωx 1,10,100 1,10,100 -
LeveldB - • -
Polarityindication - - -
Accuracy 2.5≅ 2.5≅ 3∞
2≅Specialfeatures Fullprotection - Zerointhemiddleofthescale
Supply 1x1.5VR6 1x1.5VR6 1x9V6F22
Dimensions(mm) 102x142x40 102x142x40 96x132x33
Weightwithpacking 470g 340g 400g
MULTIMETERS
PortableMeters
63
07035.00
Portablemetersforschoolsareindispensableforexer-cisesinphysicsandpracticalwork.Themetersenableawide rangeofmeasurements andare adapted forpupils’work.Theyexcelinahighdegreeofprotectionagainstoverloads,user-friendlyapplicationaswellasanaccuratereadoutandextremelyhighreliability.
TYPE 07035.00 07036.00 07037.00 07038.00 07039.00 07027.01 07021.01 07026.00
Typeofmeasurement Voltmeter Ammeter Voltmeter= Ammeter= Galvanometer= Multimeter Multimeter Multimeter
=Voltage~
0.3V...300V
60mV 5/15V - -0.06V...
60V240mV...
600V0.1V...1000V
10V...300V
- 5/15V - -6V...
60V6V...
600V1V...1000V
=Current~
-1mA3A
- 1/5A 3.5mA100μA...
6A0.12mA
6A0.1mA...
10A
-1mA3A
- 1/5A 3.5mA6mA...
6A6mA...
6A1mA...
10A
Resistance(Ωx) - - - - - - - 1,10,100
Level(dB) - - - - - - - -10...+12
Inputresistance=~
30kΩ/V - 1kΩ/V - - 10kΩ/V 10kΩ/V 12kΩ/V
10kΩ/V 4kΩ/V 4kΩ/V 4kΩ/V
Accuracy 2.5≅ 2.5≅ 1.5 1.5 1.5 2.5≅ 1.5=2.5∞
1.5=2.5∞
Frequencyrange15Hz...
10kHz- - - -
15Hz...11kHz
20Hz...10kHz
15Hz...11kHz
Specialfeatures - -Scalewithamirror
Scalewithamirror
Zeropointinthemiddleofthescale
Zeropointinthemiddleofthescale
Scalewithamirror
Scalewithamirror
Supply - - - - - - - 2x1.5VR6
Dimensions(mm) 100x165x55
Weightwithpacking 360g 430g 290g 280g 270g 520g 550g 520g
EDUCATIONALPROGRAMME
PortableMeters
64
Ithasa31/2-digitdisplayandisappropriateformeasuringoffoodstuffsbytheHACCPsystem.BymeansofappropriatePt100sensors,temperaturecanbemeasuredfrom:•-50°Cto+200°C.•Error:<0.2°K•Dimensions:135x69x28mm•Supply:2x1.5VLR03
MI7022DIGITALTEMPERATUREMETER
TYPE OF TEMPERATURE SENSORS FOR MI 7022
Applicationrange -50˚C...+200˚C.
Sensor Pt100,conformsstandardIEC-751,error1/3B
Dimensionsofthetippart φ3mmx150mm
We produce two types of sensors:
AT0621 fordirectconnectiontothemeasuringdevice
EquipmentandAccessories
65
TYPE OF TEMPERATURE SENSORS FOR MI 7022
Applicationrange -50˚C...+200˚C.
Sensor Pt100,conformsstandardIEC-751,error1/3B
Dimensionsofthetippart φ3mmx150mm
We produce two types of sensors:
AT0621 fordirectconnectiontothemeasuringdevice
AR0101
AR0105
SHUNTSFORADD-ONDimensionsofshuntsareadaptedtometerconnectioncontactsandcanbeeasilyfixedwithM4screws.Thebasicmeterisprovidedwiththemeasuringsystem5mAandmeasuresvoltagedrop60mV.Onlyacorrespondingscalehastobeinserted.Theshuntscanbeusedonthehousings96x96mmand72x72mm,andBN0103andBN0203meters.Theaccuracyclassis0.5.
SEPARATESHUNTS
Separate shunts increase DC current ratings when connected with themeterwithamovingcoil.Voltagedrop is60mV.Connectionwireswith0.035Ω resistanceareenclosed to theshunt.DimensionscomplywithDIN43703.Theaccuracyclassis0.5.
RATED CURRENT (A)/60 mV MASS (kg)
1,1.5 0.18
2.5,4,6,10,15,25 0.20
40,60,100,150 0.14
250 0.55
400 0.80
600 0.84
1000 1.50
1500 2
2500 3
RATED CURRENT (A)/60 mV
1,1.5,2,2.5,4,5,6,8,10,15,20
Otherratingsandvoltagedropsareavailableonrequest.
Dimensionaldrawingsonpage86.
SHUNTS
EquipmentandAccessories
66
ASK31,5 ASK61,4
Current measuring transformers areused for measuring AC currents.Secondary current is 5 A, ratedfrequency from 50 Hz to 60 Hz. Theaccuracyclassis1.
TYPE POWER I prim/5 A Primary cable
ASR20.3 1VA..7.5VA 50A..300A ø21mm
ASR201.3 1VA..7.5VA 50A..300A ø21mm
ASR21.3 1VA..10VA 100A..600A ø22.5mm
ASR22.3 1VA..15VA 40A..600A ø22.5mm
ASR22.32U 2.5VA..10VA 100A..600A ø22.5mm
ASK205.3 1VA..10VA 60A..400A 20x5mm,ø17.5mm
ASK21.3 1VA..15VA 40A..600A 20x10mm,ø19.2mm
ASK231.5 1VA..15VA 50A..600A 30x10mm,ø28mm
ASK31.3 1VA..10VA 50A..750A 30x10mm,2x20x10mm,ø26mm
ASK31.32U 2.5VA..15VA 100A..600A 30x10mm,2x20x10mm,ø26mm
ASK318.3 1VA..15VA 60A..750A 31x18mm,ø26mm
ASK31.4 1.25VA..15VA 50A..750A 30x10mm,2x20x10mm,ø28mm
ASK31.42U 2.5VA..15VA 100A..600A 30x10mm,2x20x10mm,ø28mm
ASK31.43U 2.5VA..15VA 100A..600A 30x10mm,2x20x10mm,ø28mm
*ASK31.5 1VA..30VA 40A..750A 30x10mm,2x20x10mm,ø28mm
ASK31.52U 2.5VA..15VA 75A..600A 30x10mm,2x20x10mm,ø28mm
ASK41.3 1VA..15VA 100A..800A 40x12mm,32x18mm,ø26mm
ASK421.4 1VA..30VA 30A..500A 20x10mm,ø20mm
ASK41.4 1.25VA..30VA 50A..1000A 40x10mm,2x30x5mm,ø32mm
ASK41.42U 2.5VA..15VA 100A..1000A 40x10mm,2x30x5mm,ø32mm
ASK41.43U 2.5VA..15VA 100A..1000A 40x10mm,2x30x5mm,ø32mm
ASK412.4 1.25VA..30VA 50A..800A 40x10mm,30x15mm,ø30,5mm
ASK541.4 1VA..30VA 30A..1000A 40x10mm,2x30x5mm,ø32mm
ASK51.4 1.5VA..30VA 100A..1250A 50x12mm,2x40x10mm,ø44mm
ASK51.42U 2.5VA..30VA 200A..1200A 50x12mm,2x40x10mm,ø44mm
ASK51.43U 2.5VA..15VA 200A..1200A 50x12mm,2x40x10mm,ø44mm
ASK561.4 2.5VA..30VA 200A..1250A 60x10mm,2x50x10mm,ø44mm
*ASK61.4 1.5VA..30VA 200A..1600A 63x10mm,2x50x10mm,ø44mm
ASK61.42U 2.5VA..30VA 250A..1600A 63x10mm,2x50x10mm,ø44mm
ASK61.43U 2.5VA..15VA 200A..1600A 63x10mm,2x50x10mm,ø44mm
ASK63.4 1.5VA..15VA 300A..2000A 60x30mm,50x40mm,ø44mm
ASK63.6 1.5VA..30VA 200A..2000A 60x30mm,ø30mm
ASK81.4 2.5VA..45VA 400A..2000A 80x10mm,60x30mm,2x60x10mm,ø55mm
ASK81.42U 5VA..30VA 500A..2000A 80x10mm,60x30mm,2x60x10mm,ø55mm
ASK101.4 5VA..45VA 500A..2500A 100x10mm,2x80x10mm,ø70mm
ASK101.42U 5VA..30VA 600A..2500A 100x10mm,2x80x10mm,ø70mm
ASK103.3 5VA..45VA 750A..3000A 2x100x10mm,3x80x10mm,ø85mm
ASK123.3 5VA..45VA 1000A..4000A 123x30mm,3x100x10mm,ø100mm
ASK129.10 5VA..45VA 1000A..7500A 120x90mm
WSK30 2.5VA..5VA 1A..20A -
WSK40 2.5VA..15VA 1A..40A -
WSK60 2.5VA..15VA 5A..30A -
WSK70.6 2.5VA..15VA 25A..150A -
Snap-onmountingforASKtype
Otherratingsandaccuracyclassesbyagreement.*onstockASK31.52.5VA50,75A;5VA100-600A,ASK61.410VA800,1000,1200,1500A
Dimensionaldrawingsareonpages84,85.
CURRENTMEASURINGTRANSFORMERS
SpecialDemands
67
General•Increasedmechanicalresistance •Non-brilliantpane •Mechanicallyresistantpane(plastic) •Frontframeinanothercolour(red,blue,yellow)•TropicalversionincompliancewithDIN40040--mechanicalmetersHVE -electronicmetersJVE •Adjustablepointer1x •Adjustablepointer2x •ProtectionofthefrontsideIP54•ProtectionofthefrontsideIP65(seepage79) • Shipversion: -mechanicalmeters -electronicmeters •Luminescentscale(72x72and96x96mm) •DCsupply24V,48V,60V •DCsupply110V,230V •Non-standardmountingposition •Protectioncoverforprotectionofconnectionterminals:-Q144,Q96,Q72,Q48 •Sparefixingelements: -H1 -mosaicfixing
Meters with moving coil•Zeropointinthemiddleoratanoptionalposition•Non-standardrating •Additionalrating •Non-standardinternalresistance •Built-inpotentiometerforrangeextension •Increaseddamping •Increasedaccuracy(error1%), -scale90° -scale240° •Mechanicalzeropointsuppression Meters with moving iron•Non-standardrating •CalibrationforDCandACquantity•Increaseddamping•Calibrationforhigherfrequency(from100Hzto500Hz)•Ammeterswith100%overload •Ammeterswithtripleormultipleoverload(max.6times)•Additionalratings•Increasedaccuracy(1%inoneselectedpoint)
Dial •Dialwithastandardscale •Dialwithanon-standardscale •Non-printedscale •Scalebyatable,acurve,acalibration •Additionaldesignationsonascale(max.15characters)•Colourdesignationonascale •Colourfieldonascale•Non-standardscaledivision •Blackdial,whiteoryellowdesignations•Transparentdial
Other meters and accessories•MQ..withprotectingtransformer •MQ../5Awithsettingtimes15,20and30min. •ZQ..withanothermeasuringrange(162/3...400Hz)•Separateshuntswithvoltagedrop75mV •Separateshuntswithvoltagedrop100mV•Separateshuntswithaccuracy0.2%
Itistechnicallynotpossibletosatisfyallthebelowstatedspecialrequirementsateachstandardversion.Apreviousagreementisthereforerequired.
GeneralExplanations
68
Scalescanbeinterchangedatsquarepanelmetersandatmetersforrailmounting(35mm)withdigit7attheendof a typedesignation (e.g. FQ0207)both at newandalreadyused instruments. This is especially convenient forthemeterswhichareconnected toacurrentorvoltagemeasuring transformerorashunt.Pushacover towardstheupperpartinthedirectionofanarrowanddrawoutthescalewithasuitabletool.Whenthescaleisreplaced,carefullyclosetheslotwiththecover.ThescalecolourcomplieswithRAL9010.
Ship versionSpecialversionsareavailableforpanelmountingintoships.ThesearemechanicallyresistantandadditionallysealedmeterswhichcomplywiththerequirementsofCRS(CroatianRegisterofShippingCo.Ltd).Themeterhousing is
markedwithananchor andLisaddedtothetypedesignation.(e.g.FQ0207L)
HousingAllsquarepanelmeterswhichcomplywithDIN43700aremadeofmechanicallyandtemperatureresistantdarkgrey(RAL9011)thermoplasticmaterial;incombustibilitycomplieswithUL94V-0.Theblack(RAL9005)frontframecom-plieswithDIN43718.Atcustomerrequestaspecialcover fortheprotectionofconnectionterminals fromcontactcanbeaddedtothemeter(IP20).
PointerAtsquaremetersthepointerisastandardtypewithanarrowedpoint.Sensitivemetersandmultimetersareprovidedwithatubeoranarrowedtubepointer.
Interchangeable scale at panel meters
standardpointer tubepointer knife-edgepointer
GeneralExplanations
69
Fixing
Thepanelmetersarefixedtotheswitchboardwiththeenclosedfixingelements:•theQsquaremetersareusuallyfixedwithscrews(figureonpage78).•byagreement,themeters(48mmx48mm)canbefixedwithspecialfixingelementsfortwoversionsofmosaicmounting(seepage78).
Degree of protection
AtypeofprotectioncomplieswithDIN40050:forahousingIP52andforconnectionterminalsIP00.IP20withprotectioncover(optional)IP54protectionprovidesforadditionalsealingofthefrontside(optional).IP65withsiliconprotectioncover(optional,seepage79).
Accuracy
TheaccuracyclassaccordingtoEN60051indicatespermitteddeviationinpercentagefromthefinalmeasuringvalueandisstatedforeachgroupseparately.
Temperature and climatic conditions
Standardmetersoperateintheambienttemperaturerangefrom-25°Cto55°C.Max.relativehumidityis80%.AccordingtoIEC60721-2-1(Classificationofenvironmentalconditions)ourinstrumentscomplywithWDaEtypeofclimate.Formoredifficultambientconditionswhenslightdamping(butnomoulds)occurs,aspecial“conditionallytropic”versionisavailable:HVE(from-25°Cto+55°C)forstandardmeterswithoutelectronicsandJVE(from-10°Cto+55°C)forthemeterswithbuilt-inelectronics.
Resistance to vibrations and shocks
Resistance to vibrations and shocks of analogue panel meters complies with EN 60051 or DIN VDE 0410/3.86standard.
GeneralExplanations
70
Position and marks
Normaloperatingpositionof thepanelmeters isvertical. Theposition ismarkedonthescaleandthemetersarecorrespondinglycalibrated.
vertically horizontallyα° atanangle(e.g.60°regardingthehorizontalposition)
OTHER SYMBOLS ON THE SCALE AND THE HOUSING COMPLY WITH EN60051 AND EN61010.
Significanceofsymbols
Measuringsystemwithamovingcoil Measuringsystemwithamovingcoil Measuringsystemwithamovingiron Bimetalmeasuringsystem Combinedmeterwithabimetal systemandamovingiron Meterwithelectronics
Vibratingmeasuringsystem Terminalforaprotectiveconductor Warning:seeApplicationInstructions TestvoltagenotcompliantwithVDE DC AC DCandAC Threephasethree-wiresystemwithbalancedload Three-phasefour-wiresystemwithbalancedload Threephasethree-wiresystemwithunbalancedload(twomeasuringsystems) Three-phasefour-wiresystemwithunbalancedload(threemeasuringsystems) Accuracyclass
Ratings in compliance with DIN 43780
Standardratingsareselectedfromthesequence1-1.2-1.5-2.5-3-4-5-6-7.5-(8)alsoconsideringdecademultiplesofthestatednumbers.UnitsonthescalearemarkedaccordingtoDIN1301.
GeneralExplanations
71
FORM
Typeofmeasurement
U,I U,I U,I I I f f P
Q
W cosϕ T
Symbolof
measuringsystem
Shipver-sion
Interch-angable
dial
Pageincata-logue
BQ0... • • • 176,177
FQ0... • • • 181,182
MQ0... • • • 183,184
CQ0... • • 179
ZQ0... • • • 173
YQ0... • • • 172
EQ0... • • • 171
WQ0... • 170
MI7350 • • • • • • • 175
KQ0... • • 185
BQ2... • • 176,177
CQ2... • • 179
ZQ2... • • 173
YQ2... • • 172
EQ2... • • 171
FQ1... • • • 169
ZQ1... • • • 169
ZQ..17 • • • 174
BN0... • 180
FN0... • 181
CN0... • 180
BQ0507 • • 176,177
FQ0507 • • 181,182
MQ0507 • • 183
BQ2507 • • 176,177
CQ2507 • • 179
Typeofmeter
GENERALDATA
DimensionalDrawings
72
Note:*with/withouttransformer
PANELMETERS
TYPE Front frame aCutting for
mounting bDimensions (mm)
Bezel height cBase
dDimensions with
packing (mm)Volume with
packing (dm3) Weight with packing (kg)
BQ0407 48 45+0.6 5 - 55x55x75 0.23 0.10
BQ0307 72 68+0.8 5.5 - 80x75x75 0.45 0.16
BQ0207 96 92+0.8 5.5 - 102x102x75 0.78 0.20
BQ0107 144 138+1 8 - 155x155x80 1.92 0.43
BQ2407 48 45+0.6 5 - 75x60x85 0.38 0.16
BQ2307 72 68+0.8 5.5 - 100x90x85 0.77 0.20
BQ2207 96 92+0.8 5.5 - 120x110x85 1.12 0.30
BQ2107 144 138+1 8 - 170x160x85 2.31 0.44
CQ0407 48 45+0.6 5 - 55x55x75 0.23 0.10
CQ0307 72 68+0.8 5.5 - 80x75x75 0.45 0.16
CQ0207 96 92+0.8 5.5 - 102x102x75 0.78 0.22
CQ0107 144 138+1 8 - 155x155x80 1.92 0.44
CQ2407 48 45+0.6 5 - 75x60x85 0.38 0.16
CQ2307 72 68+0.8 5.5 - 100x90x85 0.77 0.20
CQ2207 96 92+0.8 5.5 - 120x110x85 1.12 0.30
CQ2107 144 138+1 8 - 170x160x85 2.31 0.44
CQ3207 96 92+0.8 5.5 - 102x102x75 0.78 0.32
FQ0407 48 45+0.6 5 - 55x55x75 0.23 0.10
FQ0307 72 68+0.8 5.5 - 80x75x75 0.45 0.16
FQ0207 96 92+0.8 5.5 - 102x102x75 0.78 0.24
FQ0107 144 138+1 8 - 155x155x80 1.92 0.40
FQ3207 96 92+0.8 5.5 - 102x102x75 0.78 0.32
ZQ0317 72 68+0.8 5.5 - 100x90x85 0.77 0.22
ZQ0217 96 92+0.8 5.5 - 120x110x85 1.12 0.32
ZQ0117 144 138+1 8 - 170x160x85 2.31 0.52
ZQ1217 96 92+0.8 5.5 - 120x110x85 1.12 0.43
ZQ1117 144 138+1 8 - 170x160x85 2.31 0.75
MQ0407 48 45+0.6 5 - 75x60x85 0.38 0.12
MQ0317 72 68+0.8 5.5 - 100x90x85 0.77 0.19/0.31*
MQ0307 72 68+0.8 5.5 - 100x90x85 0.77 0.15
MQ0217 96 92+0.8 5.5 - 120x110x85 1.12 0.27
MQ0207 96 92+0.8 5.5 - 120x110x85 1.12 0.22
MQ0107 144 138+1 8 - 170x160x85 2.31 0.50
MQ0117 144 138+1 8 - 170x160x85 2.31 0.55
ZQ0407 48 45+0.6 5 - 55x55x75 0.23 0.16
ZQ0307 72 68+0.8 5.5 - 80x75x75 0.45 0.20
ZQ0207 96 92+0.8 5.5 - 102x102x75 0.78 0.20
ZQ0107 144 138+1 8 - 155x155x80 1.92 0.40
ZQ2307 72 68+0.8 5.5 - 100x90x120 1.08 0.20
ZQ2207 96 92+0.8 5.5 - 160x105x102 1.71 0.20
ZQ2107 144 138+1 8 - 150x150x137 3.08 0.40
YQ0307 72 68+0.8 5.5 29 102x76x104 0.81 0.24
YQ0207 96 92+0.8 5.5 27.3 102x120x105 1.29 0.35
DimensionalDrawings
73
TYPE Front frame aCutting for
mounting bDimensions (mm)
Bezel height cBase
d
Dimensions with packing
(mm)
Volume with packing (dm3)
Weight with packing (kg)
YQ0107 144 138+1 8 27.3 155x155x137 3.29 0.60
YQ2307 72 68+0.8 5.5 29 102x76x104 0.81 0.28
YQ2207 96 92+0.8 5.5 27.3 102x120x105 1.29 0.45
YQ2107 144 138+1 8 27.3 155x155x137 3.29 0.65
EQ0307 72 68+0.8 5.5 29 102x76x104 0.81 0.24
EQ0207 96 92+0.8 5.5 27.3 102x120x105 1.29 0.35
EQ0107 144 138+1 8 27.3 155x155x137 3.29 0.60
EQ2307 72 68+0.8 5.5 29 102x76x104 0.81 0.28
EQ2207 96 92+0.8 5.5 27.3 102x120x105 1.29 0.45
EQ2107 144 138+1 8 27.3 155x155x137 3.29 0.65
WQ0217 96 92+0.8 5.5 54.3 160x105x102 1.71 0.90
WQ1217 96 92+0.8 5.5 54.3 160x105x102 1.71 0.95
WQ1208 96 92+0.8 5.5 54.3 160x105x102 1.71 0.90
WQ0207 96 92+0.8 5.5 54.3 160x105x102 1.71 0.95
WQ2207 96 92+0.8 5.5 54.3 160x105x102 1.71 0.95
WQ1247 96 92+0.8 5.5 27.3 102x115x95 1.11 0.90
KQ0207 96 92+0.8 5.5 - 105x105x95 1.05 0.30
MI7350 96 92+0.8 5.5 54.3 98x152x100 1.49 0.60
SQ0204 96 92+0.8 5.5 48.5 102x102x120 1.25 0.50
SQ0104 144 138+1 8 28 150x150x140 2.57 0.71
SQ0114 144 138+1 8 28 150x150x140 2.57 0.71
SQ0214 96 92+0.8 5.5 48.5 102x102x120 1.25 0.55
ZQ1207 96 92+0.8 5.5 54.3 160x105x102 1.71 0.50
ZQ1208 96 92+0.8 5.5 54.3 97x61x97 0.57 0.26
FQ1207 96 92+0.8 5.5 54.3 160x105x102 0.78 0.45
FQ1208 96 92+0.8 5.5 54.3 102x102x75 1.39 0.50
MC740,MC744,MC750,MC754
ACsupply96 92+0.8 5.5 37 213x138x152 5.03 0.80
MC740,MC744,MC750,MC754
DCsupply96 92+0.8 5.5 37 213x138x152 5.03 0.65
MC760,MC764ACsupply
110 87.7+0.8 19 - 213x138x152 5.03 0.80
MC760,MC764DCsupply
110 87.7+0.8 19 - 213x138x152 5.03 0.65
UMC740ACsupply 110 87.7+0.8 19 - 213x138x152 5.03 0.80
UMC740DCsupply 110 87.7+0.8 19 - 213x138x152 5.03 0.65
UMC750ACsupply 110 87.7+0.8 19 - 213x138x152 5.03 0.80
UMC750DCsupply 110 87.7+0.8 19 - 213x138x152 5.03 0.65
UMC760ACsupply 110 87.7+0.8 19 - 213x138x152 5.03 0.75
UMC760DCsupply 110 87.7+0.8 19 - 213x138x152 5.03 0.65
PANELMETERS
DimensionalDrawings
74
SCALES,MEASURINGTRANSDUCERS-weight,dimensions
Measuring transducers - weight
TYPEPowered from
measuring circuitUniversal power supply AC power supply
Weight-kg Weight-kg
Weightoftransducerwith
communicationand3outputs
-kg
Weight-kgWeightoftransducerwith
communication-kg
(U)MT560 0.600
(U)MT550 0.600
(U)MT540 0.600
(U)MT518 0.420
(U)MT516 0.420
(U)MT511 0.420
(U)MT510 0.420
MT406 0.280
MT408 0.280
MT416 0.340
MT418 0.340
MT440 0.370
MI450 0.282 0.372
MI452 0.282 0.372
MI454 0.282 0.372
MI456 0.282 0.372
MI458 0.282 0.372
MI485 0.293
Scales
TYPE Dimensions (mm)Spread without
cutout (mm)Weight (g)
xQx107 131x129.6 16980 19.81
xQx207 84.7x86.3 7310 8.53
xQx307 62.7x61.4 3850 4.49
xQx407 39.4x40.1 1580 1.84
xQx507 39.4x40.1 1580 1.84
DimensionalDrawings
75
MEASURINGTRANSDUCERS,MEASURINGCENTRES,COMMUNICATIONADAPTERS,-weight,dimensions
Measuring transducers - dimensions
TYPE Dimensions with packing - mm Volume with packing - dm3
MT560/UMT560 135x90x170 2.065
MT550/UMT550 135x90x170 2.065
MT540/UMT540 135x90x170 2,065
MT518/UMT518 135x85x105 1.205
MT516/UMT516 135x85x105 1.205
MT511/UMT511 135x85x105 1.205
MT510/UMT510 135x85x105 1.205
MT406 123x61x87 0.964
MT408 123x61x87 0.964
MT416 123x61x87 0.964
MT418 123x61x87 0.964
MT440 135x85x105 1.205
MI450 123x61x87 0.653
MI452 123x61x87 0.653
MI454 123x61x87 0.653
MI456 123x61x87 0.653
MI458 123x61x87 0.653
MI485 123x61x87 0.653
Measuring centres
TYPEDimensions with packing
(mm)
Volume with packing
(dm3)
Weight
(kg)
MC640,MC650,MC660 155x215x93 3.099 0.4
MC646,MC656,MC666 155x215x93 3.099 0.55
Communication adapters
TYPEDimensions with packing (mm) Volume with packing
(dm3)
Weight
(kg)
MI480 123x87x111 1.19 0.53AC/0.33UNI*
MI485 123x87x60 0.64 0.32AC/0.24UNI*
MI486/488 123x87x60 0.64 0.36AC/0.25UNI*
*AC-auxiliarypowersupply;UNI-universalpowersupply.
DimensionalDrawings
76
Dimensions (on special request)
TYPEEQ0107
YQ0107
EQ2107
YQ2107
EQ0207
YQ0207
EQ2207
YQ2207
Bezelheight(mm) a 144 144 96 96
Panelcut-out(mm) b 138+1.0 138+1.0 92+0.8 92+0.8
Bezelheight(mm) c 144 144 96 96
Protectioncover(mm) e 90 90 90 92
Scaleslength(mm) 135 135 95 95
Base(mm) d 54 54 28 54
Weightapprox. 0.9 1.1 0.5 0.7
ENERGYMETERSFORRAILMOUNTING-weight,dimensions
*Figureonpage77.
DimensionalDrawings
77
1)ForrangesFQ=30...60AandBQ=7.5…60A:M62)ForrangesFQ=30...60AandBQ=7.5…60A:59mm3)Protectioncovere=(Q48=42.5mm,Q72=66.5mm,Q96andQ144=90mm)
Note:Dimensionsof a, b, c, d
Protection cover for Q96 instruments
Panel meters: dimensions
DimensionaldrawingsofSQ0xx4canbeseenintableonpage80andMC/UMC7x0onpage82.
canbeseenintableonpage72,73.
ANALOGUEMETERS
DimensionalDrawings
78
Fixing elements
1) forrangesFN=15...60AandBN=7.5…60A:M6
TYPE DIMENSIONS (mm)
A C D E F G H
BN0103forratingsfrom7.5A
to60A13 11.5 64+/-0.2 85 25+/-0.2 25+/-0.2 72
BN0103 16.5 11.5 64+/-0.2 85 25+/-0.2 25+/-0.2 72
BN0203forratingsfrom7.5A
to60A13 16 103+/-0.2 105 31+/-0.2 51+/-0.2 96
BN0203 16.5 16 103+/-0.2 105 31+/-0.2 51+/-0.2 96
CN0103 13 11.5 64+/-0.2 85 25+/-0.2 25+/-0.2 72
CN0203 13 16 103+/-0.2 105 31+/-0.2 51+/-0.2 96
FN0103 1321) 11.5 103+/-0.2 85 25+/-0.2 25+/-0.2 72
FN0201 1321) 16 103+/-0.2 105 31+/-0.2 51+/-0.2 96
with a screw for mosaic fixing
1)forrangesFN=15...60AandBN=7.5…60A:16.5mm
ANALOGUEMETERS
DimensionalDrawings
79
BQ0507FQ0507
MQ0507CQ0507BQ2507CQ2507
or
Measuring transformer for add-on 1 or 5 A for CQ 0407 and CQ 2407
Protection of front side IP65
B H Ti B1 H1 Size
54 54 8 48.4 48.4 Q48
78 78 8 72.4 72.4 Q72
102 102 8 96.4 96.4 Q96
150 150 9 144.4 144.4 Q144
MEASURINGTRANSFORMER
DimensionalDrawings
80
SYNCHROSCOPEMiBOX
SYNCHROSCOPE
MiBOX
DimensionalDrawings
81
MI 4xx
MT 406, MT 408, MT 416, MT 418
RD 500
MT 440
MT 5x0/UMT5x0 MT 51x/UMT 51x
MEASURINGTRANSDUCERS
DimensionalDrawings
82
MC 764, MC 754, MC 744
MC 330, MC 320
MC 760, MC 750, MC 740UMC 760, UMC 750, UMC 740
MEASURINGCENTRES
MC 6x0, MC 6x6
DimensionalDrawings
83
DM 210 DM 202, DM 206, DM 208
DM 302, DM 306, DM 308, DM 310
DIGITALMETERS
DimensionalDrawings
CURRENTMEASURINGTRANSFORMERS
1.ASK61.4, ASK61.42U, ASK61.43U 2.ASK63.4
1.ASK51.4, ASK51.42U, ASK51.43U 2.ASK561.4
1.ASK412.4 2.ASK541.4
1.ASK421.4 2.ASK41.4, ASK41.42U, ASK41.43U
1.ASK31.5, ASK31.52U 2.ASK41.3
1.ASK318.3 2.ASK31.4, ASK31.42U, ASK31.43U
1.ASK231.5 2.ASK31.3, ASK31.32U
1.ASK205.3 2.ASK21.3
1.ASR21.3 2.ASR22.3, ASR22.32U
1.ASR20.3 2.ASR201.3
TYPE FRONT BOTTOM FROMSIDE
1. 2. 1. 2. 1. 2.
1. 2. 1. 2. 1. 2.
1. 2. 1. 2. 1. 2.
1. 2. 1. 2. 1. 2.
1. 2. 1. 2. 1. 2.
1. 2. 1. 2. 1. 2.
1. 2. 1. 2. 1. 2.
1. 2. 1. 2. 1. 2.
1. 2. 1. 2. 1. 2.
1. 2. 1. 2. 1. 2.
84
DimensionalDrawings
85
1.WSK60 2.WSK70.6
1.WSK30 2.WSK40
1.ASK123.3 2.ASK129.10
1.ASK101.4, ASK101.42U 2.ASK103.3
1.ASK63.6 2.ASK81.4, ASK81.42U
TYPE FRONT BOTTOM FROMSIDE
1. 2. 1. 2. 1. 2.
1. 2. 1. 2. 1. 2.
1. 2. 1. 2. 1. 2.
1. 2. 1. 2. 1. 2.
1. 2. 1. 2. 1.
CURRENTMEASURINGTRANSFORMERS
Current measuring transformers - dimensions, weightTYPE Width Height Depth (with pedestal) Primary cable Diameter Weight range
ASR20.3 44 65 30(62) - 21 0.152 0.191
ASR201.3 44 64.5 30 - 21 0.150 0.190
ASR21.3 48,5 65 30(62) - 22,5 0.230 0.280
ASR22.3 60 78.5 30(62) - 22,5 0.250 0.280
ASK205.3 48,5 65 30(62) 20x5 17,5 0.200 0.198
ASK21.3 60 78.5 30(62) 20x10 19,2 0.315 0.268
ASK231.5 49,5 70 50(82) 30x10 28 0.340 0.320
ASK31.3 60 78.5 30(62) 30x10.2x20x10 26 0.267 0.240
ASK318.3 60 78.5 30(62) 31x18 26 0.238 0.250
ASK31.4 60 78.5 40(72) 30x10.2x2010 28 0.375 0.300
ASK31.5 60 78.5 50(82) 30x10.2x2010 28 0.450 0.350
ASK41.3 60 78.5 30(62) 40x13.32x18 28 0.220 0.240
ASK421.4 70 88.5 40(72) 20x10 26 0.712 0.420
ASK41.4 70 88.5 40(72) 40x10.2x30x5 20 0.462 0.345
ASK412.4 70 88.5 40(72) 40x10.2x30x15 32 0.475 0.420
ASK541.4 85 101.5 40(72) 40x10.2x30x5 30,5 0.910 0.450
ASK51.4 85 101.5 40(72) 50x12.2x40x10 32 0.536 0.460
ASK561.4 85 101.5 40(72) 60x10.2x50x10 44 0.472 0.490
ASK61.4 95 108.5 40(72) 63x10.2x50x10 44 0.520 0.490
ASK63.4 95 108.5 40(72) 60x30.5x40 44 0.420 0.430
ASK63.6 88 132 60(92) 60x30 44 0.740 0.835
ASK81.4 120 126.5 40(72) 80x10.6x30.2x6x10 30 1.000 0.565
ASK101.4 130 144 40(72) 100x10.2x80x10 55 0.550 0.713
ASK103.3 172 187.5 31(62) 2x100x10.3x80x10 70 0.800 0.750
ASK123.3 172 187.5 31(62) 123x30.3x100x10 85 0.800 0.850
ASK129.1 250 250 100(132) 120x90 100 3.000 3.400
WSK30 60 78.5 30(62)mm - - 0.290 0.270
WSK40 70 88.5 40(72)mm - - 0.320 0.412
WSK60 70 88.5 60(92)mm - - 0.410 0.460
WSK70.6 70 85 60(76)mm - - 0.520 0.580
DimensionalDrawings
86
A B
SHUNTS
Dimensions (mm) Current through separate shunt (A)
1,1.5,2.5,4 4060 250 400 600 1000 1500 2500
6101525 100150
PossibilityA PossibilityB
a1 90 100 145 165
a2 28 33 55 65
b1 20 20 30 40 40 60 90 120
b2 - - 15 20 20 30 21 30
b3 - - - - 48 60
c1 8 8 10
c2 - - 10
e 78 80 105 115
h1 - 30
No.ofterminals 2x1 2x2
Fixingscrew M5x12 M8x15 M12x40 M16x45 M16x45 M20x50 M16x45 M20x50
WasherDIN125 5.3 8.4 13.5 17 17 21 17 21
SpringwasherDIN127 - 12 16 16 20 16 20
Nut - M12 M16 M16 M20 M16 M20
Voltageterminals 2cylindricalscrewsM5x8(DIN84-4)and2washers5.3
ConnectionDiagrams
87
CONNECTIONVoltageinputscanbeconnectedeitherdirectlytolow-voltagenetworkorviaahigh-voltagetransformertohigh-voltagenetwork.Currentinputsshallbeconnectedtonetworkviaacorrespondingcurrenttransformer.
MULTIMETERMC330,ENERGYMETERMC320
3u−three-wire,unbalancedload 4b−four-wire,balancedload
1b−single-wire,balancedload 3b−three-wire,balancedload
4u−four-wire,unbalancedload
ConnectionDiagrams
88
Convertervoltageinputscanbeconnecteddirectlytolow-voltagenetworkortheycanbeconnectedviaahigh-voltagetransformertohigh-voltagenetwork.Currentinputsshallbeconnectedtonetworkviaacorrespondingcurrenttransformer.
1b - single phase, balanced load 3b - three-phase, three wires, balanced load
3u - three-phase, three wires, unbalanced load
4b - three-phase, four wires, balanced load
4u - three-phase, four wires, unbalanced load
MEASURINGCENTRESMC7x0/UMC7x0-Ethernet
l
L
l
L
l
L l
L
l
L
l
Ll
Ll
L
ConnectionDiagrams
89
Convertervoltageinputscanbeconnecteddirectlytolow-voltagenetworkortheycanbeconnectedviaahigh-voltagetransformertohigh-voltagenetwork.Currentinputsshallbeconnectedtonetworkviaacorrespondingcurrenttransformer.
1b - single phase, balanced load 3b - three-phase, three wires, balanced load
3u - three-phase, three wires, unbalanced load 4b - three-phase, four wires, balanced load
4u - three-phase, four wires, unbalanced load
MEASURINGCENTRESMC7x0/UMC7x0-RS232/485
l
Ll
L
l
Ll
L
l
LL
ll
L
ConnectionDiagrams
90
Voltageinputscanbeconnectedeitherdirectlytolow-voltagenetworkortheycanbeconnectedviaahigh-voltagetransformertohigh-voltagenetwork.Currentinputsshallbeconnectedtonetworkviaacorrespondingcurrenttransformer.
1b - single wire, balanced load 3b - Three-phase, three wires, balanced load
3u - three-phase, three wires, unbalanced load 4b - hree-phase, four wires, balanced load
4u - three-phase, four wires, unbalanced load
MEASURINGCENTRESMC7x4
l
Ll
L
l
Ll
L
l
LL
ll
L
ConnectionDiagrams
91
1b − single phase, balanced load 3b − three-phase, three wires, balanced load
3u − three-phase, three wires, balanced load 4b − three-phase, four wires, balanced load
4u −three-phase, four wires, unbalanced load
MEASURINGCENTRESMC6x6(DIRECTCONNECTION)
ConnectionDiagrams
92
1b − single phase, balanced load 3b − three-phase, three wires, balanced load
3u − three-phase, three wires, balanced load 4b − three-phase, four wires, balanced load
4u − three-phase, four wires, unbalanced load
MEASURINGCENTRESMC6x0(CONNECTIONVIACURRENTTRANSFORMER)
ConnectionDiagrams
93
1b 3b 3u 4b 4uYQxx07 * * * * *EQxx07 * * * * *WQxx07 * * * * *
1b
3b 3u
4b 4u
Note:Connectionterminals19,20,21aremissingatEQYQ,WQtypes.Connectionterminals13,14areavailableonlyforinstrumentswithexternalpowersupply.
PANELMETERS
b − balanced load u − unbalanced load
ConnectionDiagrams
94
1b − single phase 1b − single phase
1b − single phase 3b − three-phase, three wires, balanced load
MEASURINGTRANSDUCERSMT5x0/UMT5x0
ConnectionDiagrams
95
3b − three-phase, three wires, balanced load 3b − three-phase, three wires, balanced load
MEASURINGTRANSDUCERSMT5x0/UMT5x0
3u − three-phase, three wires, unbalanced load 3u − three-phase, three wires, unbalanced load
ConnectionDiagrams
96
MEASURINGTRANSDUCERSMT5x0/UMT5x0
3u − three-phase, three wires, unbalanced load 3u − three-phase, three wires, unbalanced load
4b − three-phase, four wires, balanced load 4b − three-phase, four wires, balanced load
ConnectionDiagrams
97
4b − three-phase, four wires, balanced load 4u − three-phase, four wires, unbalanced load
4u − three-phase, four wires, unbalanced load 4u − three-phase, four wires, unbalanced load
MEASURINGTRANSDUCERSMT5x0/UMT5x0
ConnectionDiagrams
98
MEASURINGTRANSDUCERSMT51x/UMT51x
1b − single phase
(U)MT 510, (U)MT 511
1b − single phase
(U)MT 510, (U)MT 511
1b − single phase 1b − single phase
(U)MT 516(U)MT 516
(U)MT 518 (U)MT 518
1b − single phase 1b − single phase
ConnectionDiagrams
99
MT 406 MT 408
MT 418MT 416
MEASURINGTRANSDUCERMT4xx
ConnectionDiagrams
100
MT 440 − 1b MT 440 − 3b
MT 440 − 4b
MT 440 − 4uMT 440 − 3u
MEASURINGTRANSDUCERMT440
ConnectionDiagrams
101
MI 485
MI 456 MI 458 MI 454
MI 452, 4-wire MI 452, 3-wire MI 452, 2-wire
MI 450, 4-wire
MI 486
MI 450, 3-wire
MI 488
MI 450, 2-wire
MI 480
Transducers can have up to four analogue outputs
MEASURINGTRANSDUCERSMT4xxCOMMUNICATIONADAPTERSMI48x
Note:Auxiliarysupplyonconnectionterminals13(-)and14(+),outputonconnectionterminals15(-)and16(+).
ConnectionDiagrams
102
CONNECTION DIAGRAMS FOR TAP POSITION METERS
CQ 2207 CQ 0207
TAPPOSITIONMETERS
ConnectionDiagrams
103
Phase to phase connection Phase to neutral connection
1)Inthecaseofphasetoneutralconnection,theconnectionschemeonthebacksideofthesynchronoscope(upperpictures)isdifferent,connectionterminaldesignationsare”L”and”N”.
Connection diagram for: ZQ 1207, ZQ 1208, FQ 1207, FQ 1208, FQ 1108, ZQ 1108 Connection diagram for: CQ 3207
Connection diagram for: FQ 3107, FQ 3207, FQ 3307
ANALOGMETERSZQ120x,FQ120x,CQ3207,FQ3x07,SQ02x4,SQ01x4,FQ1108,ZQ1108
Connection diagram for: SQ 02x4, SQ 01x4
Connection terminal number Connection designation Use of terminal
1 L11) Systemvoltage
2 L21) Systemvoltage
3 L11) Generatorvoltage
4 L21) Generatorvoltage
5 SYNC. Relayoutput
6 SYNC. Relayoutput
7 STATUS Statusoutput
8 STATUS Statusoutput
InstrumentsConformitytoStandards
104
OVERLOADSOFSHORTDURATION
Typeofinstrument Range Testcondition Standardrequirements
CQ2207 1A 0.5s;25xIn 2xUn
Accordingto60051-1:2000Directactingindicatinganalogueelectricalmeasuringinstruments
andtheiraccessories-Part1:Definitionsandgeneral
requirementscommontoallparts10xIn-9x0,5s+1x5s/60s2xUn-
9x0,5s+1x5s/60s
CQ2207 1A 0.5s;30xIn 2xUn
CQ2207 1A 0.5s;50xIn 2xUn
CQ2207 1A 1s;25xIn 2xUn
CQ2207 1A 1s;30xIn 2xUn
CQ2207 1A 1s;50xIn 2xUn
CQ2207 5A 0.5s;25xIn 2xUn
CQ2207 5A 0.5s;30xIn 2xUn
CQ2207 5A 0.5s;40xIn 2xUn
CQ2207 5A 1s;25xIn 2xUn
CQ2207 5A 1s;30xIn 2xUn
CQ2207 5A 1s;40xIn 2xUn
EQ2207 1A 0.5s;25xIn 2xUn
EQ2207 1A 0.5s;30xIn 2xUn
EQ2207 1A 0.5s;50xIn 2xUn
EQ2207 1A 1s;25xIn 2xUn
EQ2207 1A 1s;30xIn 2xUn
EQ2207 1A 1s;50xIn 2xUn
EQ2207 5A 1s;25xIn 2xUn
EQ2207 5A 1s;30xIn 2xUn
EQ2207 5A 1s;50xIn 2xUn
FQ0207 1A 0.5s;25xIn 2xUn
FQ0207 1A 0.5s;30xIn 2xUn
FQ0207 1A 0.5s;50xIn 2xUn
FQ0207 1A 1s;25xIn 2xUn
FQ0207 1A 1s;30xIn 2xUn
FQ0207 1A 1s;50xIn 2xUn
FQ0207 5A 0.5s;25xIn 2xUn
FQ0207 5A 0.5s;30xIn 2xUn
FQ0207 5A 0.5s;50xIn 2xUn
FQ0207 5A 1s;50xIn 2xUn
InstrumentsConformitytoStandards
105
Typeofproduct Conformitytostandard
MeasuringcentresMC760 IEC62052-11:2004-Electricitymeteringequipment(ac)Generalrequirements,testsandtestconditionsPart11:Meteringequipment" IEC62053-21:2003-Electricitymeteringequipment(a.c.)Particularrequirements-Part21:Staticmetersforactiveenergy (classes1and2) IEC62053-31:2003-Electricitymeteringequipment(a.c.)Particularrequirements-Part31:Pulseoutputdevicesforelectro mechanicalandelectronicmeters(twowiresonly) IEC61010-1:2001-Safetyrequirementsforelectricalequipmentformeasurement,controlandlaboratoryuse-Part1:Generalrequirements IEC61326-1:2003-EMCrequirementsforelectricalequipmentformeasurement,controlandlaboratoryuse-Part1: Generalrequirements IEC61000-4-5:2001-Electromagneticcompatibility(EMC)-Part4-5:Testingandmeasurementstechniques-Surgeimmunitytest IEC61000-4-7:2002-Electromagneticcompatibility(EMC)-Part4-7:Testingandmeasurementstechniques-Generalguide onharmonicsandinterharmonicsmeasurementsandinstrumentation,forpowersupplysystemsandequipmentconnectedthereto IEC61000-4-15:2003-Electromagneticcompatibility(EMC)-Part4:Testingandmeasurementstechniques-Section15: Flickermeter-Functionalanddesignspecifications IEC61000-4-30:2003-Electromagneticcompatibility(EMC)-Part4-30:Testingandmeasurementstechniques-Power qualitymeasurementmethodsMC750,MC740, IEC62052-11:2004-Electricitymeteringequipment(ac)MC754,MC744 Generalrequirements,testsandtestconditionsPart11:Meteringequipment" IEC62053-21:2003-Electricitymeteringequipment(a.c.)Particularrequirements-Part21:Staticmetersforactiveenergy (classes1and2) IEC61010-1:2001-Safetyrequirementsforelectricalequipmentformeasurement,controlandlaboratoryuse-Part1:Generalrequirements IEC61326-1:2003-EMCrequirementsforelectricalequipmentformeasurement,controlandlaboratoryuse-Part1: Generalrequirements IEC61000-4-5:2001-Electromagneticcompatibility(EMC)-Part4-5:Testingandmeasurementstechniques-SurgeimmunitytestMC710 IEC61010-1:2001-Safetyrequirementsforelectricalequipmentformeasurement,controlandlaboratoryuse-Part1:Generalrequirements IEC61326-1:2003-EMCrequirementsforelectricalequipmentformeasurement,controlandlaboratoryuse-Part1: Generalrequirements IEC61000-4-5:2001-Electromagneticcompatibility(EMC)-Part4-5:Testingandmeasurementstechniques-Surgeimmunitytest
CommunicationadaptersMI480,MI485,MI486,MI488 IEC55024:2000-Informationtechnologyequipment-Immunitycharacteristics-Limitsandmethodofmeasurement(CISPR 24:1997,modified) IEC61010-1:2001-Safetyrequirementsforelectricalequipmentformeasurement,controlandlaboratory use-Part1:Generalrequirements IEC61326-1:2003-EMCrequirementsforelectricalequipmentformeasurement,controlandlaboratoryuse-Part1:Generalrequirements IEC61000-4-3:1995-2-Electromagneticcompatibility(EMC)-Part4:Testingandmeasurementstechniques-Section3 Radiated,radio-frequency,electromagneticfieldimmunitytestMeasuringtransducersMI400,MI401,MI404,MI413, IEC688:1992-Electricalmeasuringtransducersforconvertinga.c.electricalquantitiestoanalogordigitalsignalsMI414,MI421,MI436,MI438 EN61326:1997+AmendmentA1:1998-Electricalequipmentformeasurement,controlandlaboratoryuseEMCrequirements "EN61000-6-2:1999-Electromagneticcompatibility(EMC) Part6-2:Genericstandards-Immunityforindustrialenvironments" IEC61010-1:2001-Safetyrequirementsforelectricalequipmentformeasurement,controlandlaboratoryuse-Part1:GeneralrequirementsMT406,MT408,MT416, IEC688:1992-Electricalmeasuringtransducersforconvertinga.c.electricalquantitiesMT418,MT420 toanalogordigitalsignals EN61326:1997+AmendmentA1:1998-Electricalequipmentformeasurement,controlandlaboratoryuseEMCrequirements IEC61010-1:2001-Safetyrequirementsforelectricalequipmentformeasurement,controlandlaboratoryuse-Part1:GeneralrequirementsMI450,MI452,MI454, CEIIEC60770-1/1999-02-Transmittersforuseinindustrial-processcontrolsystemMI456andMI458 CEIIEC1298-1/1995-07-Processmeasurementsandcontroldevices-Generalmethodsandproceduresforevaluating performance;•Generalconsiderations CEIIEC1298-2/1995-07-Processmeasurementsandcontroldevices-Generalmethodsandproceduresforevaluating performance;•Testsunderreferenceconditions CEIIEC1298-3/1995-07-Processmeasurementsandcontroldevices-Generalmethodsandproceduresforevaluating performance;•Testsforeffectsofinfluencequantities
InstrumentsConformitytoStandards
106
CEIIEC1298-4/1995-07-Processmeasurementsandcontroldevice-Generalmethodsandproceduresforevaluating performance;•Evaluationreportcontent IEC61010-1:2001-Safetyrequirementsforelectricalequipmentformeasurement,controlandlaboratoryuse-Part1:GeneralrequirementsEnergymetersWQ0207,WQ0217,WQ1217,WQ2207 EN61036:1996-Alternatingcurrentstaticwatt-hourmetersforactiveenergy(classes1and2) EN61010-1:1993+AmendmentA3:1995-Safetyrequirementsforelectricalequipmentformeasurement,controland laboratoryuse.Part1-GeneralrequirementsSynchronizationmetersSQ0204inSQ0214 EN60051-5:1995-Directactingindicatinganalogueelectricalmeasuringinstrumentsandtheiraccessories.Special requirementsforphasemeters,powerfactormetersandsynchroscopes. EN61010-1:2002-Safetyrequirementsforelectricalequipmentformeasurement,controlandlaboratoryuse.Part1- Generalrequirements EN61326:1998-Electricalequipmentformeasurement,controlandlaboratoryuse-EMCrequirementsZQ1207 EN61326:1998-Electricalequipmentformeasurement,controlandlaboratoryuse-EMCrequirements EN60051-1:2000-Directactingindicatinganalogueelectricalinstrumentsandtheiraccessories-Part1:Definitions andgeneralrequirementstoallparts EN60051-4:1995-Directactingindicatinganalogueelectricalinstrumentsandtheiraccessories-Part4:Special requirementsforfrequencymeters EN60051-9:1995-Directactingindicatinganalogueelectricalinstrumentsandtheiraccessories-Part9: Recommendedtestmethods EN61010-1:2002-Safetyrequirementsforelectricalequipmentformeasurement,controlandlaboratoryuse.Part1- GeneralrequirementsFQ1207 EN60051-1:2000-Directactingindicatinganalogueelectricalinstrumentsandtheiraccessories-Part1:Definitions andgeneralrequirementstoallparts EN60051-2:1995-Directactingindicatinganalogueelectricalinstrumentsandtheiraccessories-Part2:Special requirementsforAmmetersandVoltmeters EN60051-9:1995-Directactingindicatinganalogueelectricalinstrumentsandtheiraccessories-Part9: Recommendedtestmethods EN61010-1:2002-Safetyrequirementsforelectricalequipmentformeasurement,controlandlaboratoryuse.Part1- Generalrequirements
PowermetersandpowerfactormetersEQ0107,EQ0207,EQ2107,EQ2207, EN61236:1998-Electricalequipmentformeasurements,controlandlaboratoryuse,EMCrequirementsYQ0107,YQ0207,YQ2107,YQ2207 EN60051-1:2000-Directactingindicatinganalogueelectricalmeasuringinstrumentsandtheiraccessories-Part1: Definitionsandgeneralrequirement EN60051-3:1995-Directactingindicatinganalogueelectricalmeasuringinstrumentsandtheiraccessories-Part3: Specialrequirementsforwattmetersandvarmeters EN60051-9:1995-Directactingindicatinganalogueelectricalmeasuringinstrumentsandtheiraccessories-Part9: Recommendedtestmethods EN61010-1:2002-Safetyrequirementsforelectricalequipmentformeasurement,controlandlaboratoryuse-Part1:GeneralrequirementsEQ0307,EQ2307,YQ0307,YQ2307 EN61236:1998-Electricalequipmentformeasurements,controlandlaboratoryuse,EMCrequirements EN60051-1:2000-Directactingindicatinganalogueelectricalmeasuringinstrumentsandtheiraccessories-Part1: Definitionsandgeneralrequirements EN60051-3:1995-Directactingindicatinganalogueelectricalmeasuringinstrumentsandtheiraccessories-Part3: Specialrequirementsforwattmetersandvarmeters EN60051-5:1995-Directactingindicatinganalogueelectricalmeasuringinstrumentsandtheiraccessories-Part5: Specialrequirementsforphasemeters,powerfactormetersandsynchroscopes. EN60051-9:1995-Directactingindicatinganalogueelectricalmeasuringinstrumentsandtheiraccessories-Part9: Recommendedtestmethods EN61010-1:2002-Safetyrequirementsforelectricalequipmentformeasurement,controlandlaboratoryuse-Part1:GeneralrequirementsFrequencymetersZQ0207,ZQ0407,ZQ0307,ZQ0107, EN61326:1998-Electricalequipmentformeasurement,controlandlaboratoryuse-EMCrequirementsZQ2307,ZQ2207,ZQ2107 EN60051-11994-Directactingindicatinganalogueelectricalmeasuringinstrumentsandtheiraccessories -Generalrequirements EN60051-41984-Directactingindicatinganalogueelectricalmeasuringinstrumentsandtheiraccessories -Frequencymeters EN60051-91988-Directactingindicatinganalogueelectricalmeasuringinstrumentsandtheiraccessories -Recommendedtestmethods. EN61010-1:2002-Safetyrequirementsforelectricalequipmentformeasurement,controlandlaboratoryuse.Part1- GeneralrequirementsReedfrequencymetersZQ0317,ZQ0217,ZQ0117, EN60051-1:2000-Directactingindicatinganalogueelectricalinstrumentsandtheiraccessories-Part1:Definitions ZQ1217,ZQ1117 andgeneralrequirementstoallparts EN60051-4:1995-Directactingindicatinganalogueelectricalinstrumentsandtheiraccessories-Part4:Special requirementsforfrequencymeters EN60051-9:1995-Directactingindicatinganalogueelectricalinstrumentsandtheiraccessories-Part9: Recommendedtestmethods EN61010-1:2002-Safetyrequirementsforelectricalequipmentformeasurement,controlandlaboratoryuse.Part1- Generalrequirements
InstrumentsConformitytoStandards
107
MetersforDCvoltageorcurrentwithmovingcoilBQ0107,BQ0207,BQ0307,BQ0407,BQ0507 EN60051-1:2000-Directactingindicatinganalogueelectricalinstrumentsandtheiraccessories-Part1:Definitions andgeneralrequirementstoallparts EN60051-2:1995-Directactingindicatinganalogueelectricalinstrumentsandtheiraccessories-Part2:Special requirementsforAmmetersandVoltmeters EN60051-9:1995-Directactingindicatinganalogueelectricalinstrumentsandtheiraccessories-Part9: Recommendedtestmethods EN61010-1:2002-Safetyrequirementsforelectricalequipmentformeasurement,controlandlaboratoryuse.Part1- GeneralrequirementsBQ2107,BQ2207,BQ2307,BQ2407,BQ2507 EN60051-1:2000-Directactingindicatinganalogueelectricalinstrumentsandtheiraccessories-Part1:Definitions andgeneralrequirementstoallparts EN60051-2:1995-Directactingindicatinganalogueelectricalinstrumentsandtheiraccessories-Part2:Special requirementsforAmmetersandVoltmeters EN60051-9:1995-Directactingindicatinganalogueelectricalinstrumentsandtheiraccessories-Part9: Recommendedtestmethods EN61010-1:2002-Safetyrequirementsforelectricalequipmentformeasurement,controlandlaboratoryuse.Part1- GeneralrequirementsMetersforDCvoltageorcurrentwithmovingcoilandrectifierCQ0107,CQ0207,CQ0307,CQ0407,CQ0507,CQ2107,CQ2207,CQ2307, EN61326:1998-Electricalequipmentformeasurement,controlandlaboratoryuse-EMCrequirementsCQ2407,CQ2507 EN60051-1:2000-Directactingindicatinganalogueelectricalinstrumentsandtheiraccessories-Part1:Definitions andgeneralrequirementstoallparts EN60051-2:1995-Directactingindicatinganalogueelectricalinstrumentsandtheiraccessories-Part2:Special requirementsforAmmetersandVoltmeters EN60051-9:1995-Directactingindicatinganalogueelectricalmeasuringinstrumentsandtheiraccessories EN61010-1:2002-Safetyrequirementsforelectricalequipmentformeasurement,controlandlaboratoryuse.Part1- GeneralrequirementsMetersforACvoltageorcurrentwithmovingironFQ0107,FQ0207,FQ0307,FQ0507,FQ0407 EN60051-1:2000-Directactingindicatinganalogueelectricalinstrumentsandtheiraccessories-Part1:Definitions andgeneralrequirementstoallparts EN60051-2:1995-Directactingindicatinganalogueelectricalinstrumentsandtheiraccessories-Part2:Special requirementsforAmmetersandVoltmeters EN60051-9:1995-Directactingindicatinganalogueelectricalinstrumentsandtheiraccessories-Part9: Recommendedtestmethods EN61010-1:2002-Safetyrequirementsforelectricalequipmentformeasurement,controlandlaboratoryuse.Part1- GeneralrequirementsFQ3207inFQ3307 EN60051-1:2000-Directactingindicatinganalogueelectricalinstrumentsandtheiraccessories-Part1:Definitions andgeneralrequirementstoallparts EN60051-2:1995-Directactingindicatinganalogueelectricalinstrumentsandtheiraccessoriess-Part2:Special requirementsforAmmetersandVoltmeters EN60051-9:1995-Directactingindicatinganalogueelectricalinstrumentsandtheiraccessories-Part9: Recommendedtestmethods EN61010-1:2002-Safetyrequirementsforelectricalequipmentformeasurement,controlandlaboratoryuse.Part1- GeneralrequirementsBimetalmaximumcurrentmetersMQ0507,MQ0407,MQ0307, EN60051-11994-DirectactingindicatinganalogueelectricalmeasuringinstrumentsandtheiraccessoriesMQ0207,MQ0107 -Generalrequirements EN60051-91988-Directactingindicatinganalogueelectricalmeasuringinstrumentsandtheiraccessories -Recommendedtestmethods. EN61010-1:2002-Safetyrequirementsforelectricalequipmentformeasurement,controlandlaboratoryuse.Part1- GeneralrequirementsCombinedbimetalmaximumcurrentmeters MQ0117,MQ0217,MQ0317 EN60051-11994-Directactingindicatinganalogueelectricalmeasuringinstrumentsandtheiraccessories -Generalrequirements EN60051-91988-Directactingindicatinganalogueelectricalmeasuringinstrumentsandtheiraccessories -Recommendedtestmethods. EN60051-2:1995-Directactingindicatinganalogueelectricalinstrumentsandtheiraccessories-Part2:Special requirementsforAmmetersandVoltmeters ESI50-2BimetallicAmmeters EN61010-1:2002-Safetyrequirementsforelectricalequipmentformeasurement,controlandlaboratoryuse.Part1- GeneralrequirementsMultimetersMI7054 EN61326:1998-Electricalequipmentformeasurement,controlandlaboratoryuse-EMCrequirements EN60051-11994-Directactingindicatinganalogueelectricalmeasuringinstrumentsandtheir accessories-Generalrequirements EN60051-71984-Directactingindicatinganalogueelectricalmeasuringinstrumentsandtheiraccessories -Multi-functioninstruments EN60051-91988-Directactingindicatinganalogueelectricalmeasuringinstrumentsandtheiraccessories -Recommendedtestmethods. EN61010-1:2002-Safetyrequirementsforelectricalequipmentformeasurement,controlandlaboratoryuse.Part1- Generalrequirements
InstrumentsConformitytoStandards
108
MI7056 EN61326:1998-Electricalequipmentformeasurement,controlandlaboratoryuse-EMCrequirements EN60051-11994-Directactingindicatinganalogueelectricalmeasuringinstrumentsandtheiraccessories -Generalrequirements EN60051-71984-Directactingindicatinganalogueelectricalmeasuringinstrumentsandtheiraccessories -Multi-functioninstruments EN60051-91988-Directactingindicatinganalogueelectricalmeasuringinstrumentsandtheiraccessories -Recommendedtestmethods EN61010-1:2002-Safetyrequirementsforelectricalequipmentformeasurement,controlandlaboratoryuse. Part1-GeneralrequirementsMI7065 EN61326:1998-Electricalequipmentformeasurement,controlandlaboratoryuse-EMCrequirements EN60051-11994-Directactingindicatinganalogueelectricalmeasuringinstrumentsandtheiraccessories -Generalrequirements EN60051-71984-Directactingindicatinganalogueelectricalmeasuringinstrumentsandtheiraccessories -Multi-functioninstruments EN60051-91988-Directactingindicatinganalogueelectricalmeasuringinstrumentsandtheiraccessories -Recommendedtestmethods EN61010-1:2002-Safetyrequirementsforelectricalequipmentformeasurement,controlandlaboratoryuse. Part1-GeneralrequirementsEducationalProgramme07035.00 EN61326:1998-Electricalequipmentformeasurement,controlandlaboratoryuse-EMCrequirements EN60051-11994-Directactingindicatinganalogueelectricalmeasuringinstrumentsandtheiraccessories -Generalrequirements EN60051-71984-Directactingindicatinganalogueelectricalmeasuringinstrumentsandtheiraccessories -Multi-functioninstruments EN60051-91988-Directactingindicatinganalogueelectricalmeasuringinstrumentsandtheiraccessories -Recommendedtestmethods EN61010-1:2002-Safetyrequirementsforelectricalequipmentformeasurement,controlandlaboratoryuse. Part1-Generalrequirements07038.00 EN61326:1998-Electricalequipmentformeasurement,controlandlaboratoryuse-EMCrequirements EN60051-11994-Directactingindicatinganalogueelectricalmeasuringinstrumentsandtheiraccessories -Generalrequirements EN60051-21984-Directactingindicatinganalogueelectricalmeasuringinstrumentsandtheiraccessories -Specialrequirementsforammetersandvoltmeters EN60051-91988-Directactingindicatinganalogueelectricalmeasuringinstrumentsandtheiraccessories -Recommendedtestmethods EN61010-1:2002-Safetyrequirementsforelectricalequipmentformeasurement,controlandlaboratoryuse. Part1-Generalrequirements07021.01 EN61326:1998-Electricalequipmentformeasurement,controlandlaboratoryuse-EMCrequirements EN60051-11994-Directactingindicatinganalogueelectricalmeasuringinstrumentsandtheiraccessories -Generalrequirements EN60051-71984-Directactingindicatinganalogueelectricalmeasuringinstrumentsandtheiraccessories -Multi-functioninstruments EN60051-91988-Directactingindicatinganalogueelectricalmeasuringinstrumentsandtheiraccessories -Recommendedtestmethods. EN61010-1:2002-Safetyrequirementsforelectricalequipmentformeasurement,controlandlaboratoryuse. Part1-Generalrequirements07026.00 EN61326:1998-Electricalequipmentformeasurement,controlandlaboratoryuse-EMCrequirements EN60051-11994-Directactingindicatinganalogueelectricalmeasuringinstrumentsandtheiraccessories -Generalrequirements EN60051-71984-Directactingindicatinganalogueelectricalmeasuringinstrumentsandtheiraccessories -Multi-functioninstruments EN60051-91988-Directactingindicatinganalogueelectricalmeasuringinstrumentsandtheiraccessories -Recommendedtestmethods. EN61010-1:2002-Safetyrequirementsforelectricalequipmentformeasurement,controlandlaboratoryuse. Part1-GeneralrequirementsDigitaltemperaturemetersMI7022 EN61326:1998-Electricalequipmentformeasurement,controlandlaboratoryuse-EMCrequirements A1:1998AmendmentA1Shunts AR0101EN60051-1:2000-Directactingindicatinganalogueelectricalinstrumentsandtheiraccessories-Part1: Definitionsandgeneralrequirementstoallparts EN60051-8:1995-Directactingindicatinganalogueelectricalinstrumentsandtheiraccessories-Part8:Special requirementsforaccessories. EN60051-9:1995-Directactingindicatinganalogueelectricalinstrumentsandtheiraccessories-Part9: Recommendedtestmethods EN61010-1:2002-Safetyrequirementsforelectricalequipmentformeasurement,controlandlaboratoryuse.Part1- Generalrequirements.
Commonstandards DIN43701:measuringratings IEC61554:1999Electricalmeasuringinstruments-dimensionsforpanelmounting DIN43802:pointers,scales DIN1451:inscriptions EN60529:1997Degreesofprotectionprovidedenclosures(IPcode) UL94V-0:selfextinguishablematerials EN61010-1:2002Safetyrequirementsforelectricalequipmentformeasurement,controlandlaboratoryuse EN61036:1998/A1:2001Alternatingcurrentstaticwatt-hourmetersforactiveenergy(Razreds1and2) DIRECTIVE2002/96/ECof27January2003onwasteelectricalandelectronicequipment(WEEE) DIRECTIVE2002/95/ECof27January2003ontherestrictionoftheuseofcertainhazardoussubstancesinEEE InstallationcategoriesaccordingtostandardiEN61010-1anddataonthelabelontheinstrument.