74
LIST OF EN1317 COMPLIANT ROAD RESTRAINT SYSTEMS January 2015 (last issue dated July 2014) CONTENTS: Safety Barriers (SB) Part 1: List of permanent safety barrier systems that the HA has been advised have been CE marked in accordance with the Construction Products Regulation (CPR). Part 2: List of permanent safety barrier systems that are not CE marked in accordance with the CPR and are accepted for use on HA roads. Temporary Safety Barriers (TSB) Parapets (P) Crash Cushions (CC) Terminals (T) Transitions (TRANS) Safety Barrier Gates (SBG) Miscellaneous (M) Truck Mounted Attenuators (TMAs) The List of EN1317 Compliant Road Restraint Systems is periodically updated. To view or download the current version of this list contact: http://www.dft.gov.uk/ha/standards/tech_info/

List of EN1317 Compliant RRS January 2015

Embed Size (px)

Citation preview

Page 1: List of EN1317 Compliant RRS January 2015

LIST OF EN1317 COMPLIANT ROAD RESTRAINT SYSTEMS

January 2015 (last issue dated July 2014)

CONTENTS:

Safety Barriers (SB) Part 1: List of permanent safety barrier systems that the HA has been advised

have been CE marked in accordance with the Construction Products Regulation (CPR).

Part 2: List of permanent safety barrier systems that are not CE marked in

accordance with the CPR and are accepted for use on HA roads.

Temporary Safety Barriers (TSB)

Parapets (P)

Crash Cushions (CC)

Terminals (T)

Transitions (TRANS)

Safety Barrier Gates (SBG)

Miscellaneous (M)

Truck Mounted Attenuators (TMAs)

The List of EN1317 Compliant Road Restraint Systems is periodically updated. To view or

download the current version of this list contact: http://www.dft.gov.uk/ha/standards/tech_info/

Page 2: List of EN1317 Compliant RRS January 2015

Sector Scheme Training Requirements, New Products, Relisted Products & Amendments January 2015

Sector Scheme Training Requirements Note from TD19/06: 1.17 All VRS installed for use on the Trunk Road network, and on all roads in Northern Ireland, must be installed and maintained by qualified personnel in accordance with Sector Schemes 2B and 5B (see Appendix A of MCHW-1), where these schemes are applicable. VRS, such as bridge and pedestrian parapets or cast in-situ concrete barriers, that are not covered by these Sector Schemes must be installed and maintained by suitably trained and experienced personnel. New Products – January 2015

•••• Safety Barriers (Permanent)

- Hill and Smith; Hi Flex Safety Fence - Asebal USA; AS-BLB.C - Asset International; VarioGuard TVRS (with non-invasive anchorages) - Ferrostrada (UK); N2W2-MARC2006 - Ferrostrada (UK); H1BL-MARC2008 - SafeRoad UK; MegaRail eb - SafeRoad UK; MegaRail ec 3.3 - SafeRoad UK; MegaRail sk - SafeRoad UK; Vik CC2-W3 - SafeRoad UK; Vik CC4-W3 - Rebloc; RB80_8_N2/W3 - Rebloc; RB80_8_H1/W4 - Rebloc; RB80_8_H2/W5 - Rebloc; RB80A_8_H2/W1 - Rebloc; RB100_2_H2/W5 - Rebloc; NB100/300_8_H2/W4

•••• Safety Barriers (Temporary)

- Rebloc; RB80_8_H1/W4 - Rebloc; RB80A_8_H2/W1 - Rebloc; RB100_2_H2/W5 - System Spengler Transportable Double Sided Precast Concrete Barrier

(height 0.81m) at N2 containment level

•••• Crash Cushions - Highway Care; TAU Medium Crash Cushion Family - Highway Care; TAU Large Crash Cushion Family - Highway Care; TAU Tube P110 Crash Cushion - Industry AMS Srl; SMA Crash Cushion Family

•••• Terminals

- SafeRoad UK; SafeEnd P1 terminal - SafeRoad UK; SafeEnd P4 Terminal

•••• Safety Barrier Gates - SafeRoad UK; Steel Step Barrier Gate

Page 3: List of EN1317 Compliant RRS January 2015

Sector Scheme Training Requirements, New Products, Relisted Products & Amendments January 2015

Note: For further details on these systems, please see relevant section within the EN1317 Compliant Road Restraint Systems List. Amendments/Other Changes

•••• Listing of in-situ concrete products under ‘Safety Barriers (Part 1)’ •••• Change of promoter for the SafeEnd system from Birsta to SafeRoad UK Ltd. •••• Change of name for Highway Care ‘Solo-bois’ product range to ‘Nature Rail’ •••• Movement of the Highway Care Armorzone Longitudinal Barrier (ALB) from

permanent to temporary safety barriers •••• Change of contact details for Brifen and Hill and Smith •••• Change of contact details for Ferrostrada (UK) Ltd

Return to Contents

Page 4: List of EN1317 Compliant RRS January 2015

SAFETY BARRIERS (PART 1)

Safety Barrier Name Containment Level Working Width Class Dynamic Deflection (m) Are DD and WW normalised? Vehicle Intrusion Class

Impact Severity Level

Name and Address of Promoter Version of EN1317-5 to which the system was CE marked

Comments

H2 W2 0.1 No NR B Ardee Precast Concrete Limited EN1317-5:2007+A1:2008Town ParksArdeeCo. LouthIrelandTel. +353 41 6856372Fax. +353 41 6857216email: [email protected] Web Site: www.ardeeprecastconcrete.com

N2 W2 0.6 No NA A Asebal EN1317-5:2007Glorieta del Agua. Edif.Aljamar

Center Portal 2Planta 1Local 1141940 Tomares (Sevilla)SpainTel: +34 944 270 084Fax: +34 944 271 507email: [email protected]

N2 W3 1.0 No NA A Asebal EN1317-5:2007Glorieta del Agua. Edif.AljamarCenter Portal 2Planta 1Local 1141940 Tomares (Sevilla)SpainTel: +34 944 270 084Fax: +34 944 271 507email: [email protected]

H1 W5 0.7 No NR B Asset International (A Division of Hill and Smith) EN1317-5:2007+A1:2008Springvale AvenueBilstonWolverhamptonWV14 0QLTel. 01902 499402Fax. 01902 402104email: [email protected] Site: www.asset-vrs.co.ukAsset International (A Division of Hill and Smith) EN1317-5:2007+A1:2008Springvale AvenueBilstonWolverhampton

N2 W6 No NA B WV14 0QLTel. 01902 499402

H2 W8 No NR B Fax. 01902 402104email: [email protected]

H1 W8 No NR B Web Site: www.asset-vrs.co.ukAsset International (A Division of Hill and Smith) EN1317-5:2007+A1:2008Springvale AvenueBilstonWolverhampton

N2 W6 No NA B WV14 0QLTel. 01902 499402

H2 W8 No NR B Fax. 01902 402104email: [email protected]

L2 W8 No NR B Web Site: www.asset-vrs.co.ukAsset International (A Division of Hill and Smith) EN1317-5:2007+A1:2008Springvale AvenueBilstonWolverhampton

N2 W4 No NA B WV14 0QLTel. 01902 499402Fax. 01902 402104email: [email protected] Site: www.asset-vrs.co.uk

Double Sided BSWF, Type NJ 93BK

AS-MEB.A

The following Safety Barriers have been successfully tested to meet the requirements of BS EN 1317 -1 and -2 and the HA has been advised that they have been CE marked in accordance with the Construction Products Directive (CPD) or Regulation (CPR) for the Containment Performance Class and Working Width Class stated below.

Essential characteristic information only is provided and confirmation is required that the system selected complies fully with all HA contractual conditions and requirements as detailed in the DMRB, MCHW, and any contract specific or site specific documentation.The Safety Barriers shall comply with the manufacturer's Specification, component descriptions and Installation procedures.

Further information on Impact Severity Levels for the product and copies of documents and drawings can be obtained from the Promoter.

NA: Not ApplicableNR: Not Reported

AS-BLB.C

SOLOGUARD Emergency and Maintenance Crossing Point System

Varioguard Double Sided Safety Barrier - SYSTEM No. 1

For a tested length of 60m between end anchors, and anchored in accordance with the EN1317

compliant test, the working width class

Varioguard Double Sided Steel Safety Barrier - SYSTEM No. 3

For a tested length of 88m between end anchors, and anchored in accordance with the EN1317

Note: For a different installation length please contact the

Promoter for information

concerning the Working Width of

the system.

Note: For a different installation length please contact the

Promoter for information

concerning the Working Width of

the system.

Varioguard 'Quick Joint' Steel Safety Barrier - SYSTEM No. 2

For a tested length of 68m between end anchors, and anchored in accordance with the EN1317

compliant test, the working width class

Note: For a different installation length please contact the

Promoter for information

concerning the Working Width of

the system.

Safety Barriers (Part 1) 1 January 2015

Page 5: List of EN1317 Compliant RRS January 2015

Safety Barrier Name Containment Level Working Width Class Dynamic Deflection (m) Are DD and WW normalised? Vehicle Intrusion Class

Impact Severity Level

Name and Address of Promoter Version of EN1317-5 to which the system was CE marked

Comments

Asset International (A Division of Hill and Smith) EN1317-5:2007+A1:2008Springvale AvenueBilstonWolverhampton

N2 W3 No NA B WV14 0QLTel. 01902 499402Fax. 01902 402104email: [email protected] Site: www.asset-vrs.co.uk

H1 W6 1.4 No NR B Asset International (A Division of Hill and Smith) EN1317-5:2007+A1:2008Springvale AvenueBilstonWolverhamptonWV14 0QLTel. 01902 499402Fax. 01902 402104email: [email protected] Site: www.asset-vrs.co.uk

H1 W6 1.4 No NR B Asset International (A Division of Hill and Smith) EN1317-5:2007+A1:2008Springvale AvenueBilstonWolverhamptonWV14 0QLTel. 01902 499402Fax. 01902 402104email: [email protected] Site: www.asset-vrs.co.uk

N2 NR No NA A Brifen (A Division of Hill and Smith) EN1317-5:2007Springvale Business and Industrial ParkBilstonWolverhampton

N2 NR No NA A West Midlands EN1317-5:2007WV14 0QLTel: 01902 499400Fax: 01902 499419Email: [email protected]: www.hill-smith.co.uk

N2 NR No NA A Brifen (A Division of Hill and Smith) EN1317-5:2007Springvale Business and Industrial Park

BilstonWolverhampton

N2 NR No NA A West Midlands EN1317-5:2007WV14 0QLTel: 01902 499400Fax: 01902 499419

N2 NR No NA A Email: [email protected] EN1317-5:2007Web: www.hill-smith.co.uk

H1 NR No NA A EN1317-5:2007

N2 W1/W2 0.0 No NA B Britpave Barrier Systems Ltd EN1317-5:2007Atrium Court

H2 W1/W2 NR Yes NR B The RingBracknellBerkshireRG12 1BWTel. 01344 393300email: [email protected] site: www.bbsbarriers.com

H2 W3 0.0 No NR B Britpave Barrier Systems Ltd EN1317-5:2007Atrium CourtThe RingBracknellBerkshireRG12 1BWTel. 01344 393300email: [email protected] site: www.bbsbarriers.com

H2 W1/W2 NR Yes NR B Britpave Barrier Systems Ltd EN1317-5:2007Atrium CourtThe RingBracknellBerkshireRG12 1BWTel. 01344 393300email: [email protected] site: www.bbsbarriers.com

Varioguard Double Sided Safety Barrier - TVRS with non invasive anchorages

Brifen 3 Rope Safety Barrier

With post centres at 1.2m the Working Width Class is: W4

With post centres at 3.2m then the Working Width Class is: W6

With post centres at 3.2m then the Working Width Class is: W5

With post centres at 3.2m the Working Width Class is: W7

With post centres at 3.2m the Working Width Class is: W5

With post centres at 3.2m the Working Width Class is: W4

Brifen 4 Rope Safety Barrier

Varioguard Single Sided Steel Safety Barrier - SYSTEM No. 4

For a tested length of 88m between end anchors, and anchored in accordance with the EN1317

Note: For a different installation length please contact the

Promoter for information

concerning the Working Width of

the system.

Varioguard Single Sided Safety Barrier - SYSTEM No. 7

Concrete Step Barrier (CSB), Issue 5 Drawing file release

Wide Concrete Step Barrier (WCSB), Issue 5 Drawing file release

Variable Concrete Step Barrier (VCSB), Issue 5 Drawing file release

Safety Barriers (Part 1) 2 January 2015

Page 6: List of EN1317 Compliant RRS January 2015

Safety Barrier Name Containment Level Working Width Class Dynamic Deflection (m) Are DD and WW normalised? Vehicle Intrusion Class

Impact Severity Level

Name and Address of Promoter Version of EN1317-5 to which the system was CE marked

Comments

H2 W3 0.0 No NR B Britpave Barrier Systems Ltd EN1317-5:2007H1 Atrium Court

The RingBracknellBerkshireRG12 1BWTel. 01344 393300email: [email protected] site: www.bbsbarriers.com

H2 W2 NR No NR B Britpave Barrier Systems Ltd EN1317-5:2007Atrium CourtThe RingBracknellBerkshireRG12 1BWTel. 01344 393300email: [email protected] site: www.bbsbarriers.com

H2 W3 NR No NR B Britpave Barrier Systems Ltd EN1317-5:2007Atrium CourtThe RingBracknellBerkshireRG12 1BWTel. 01344 393300email: [email protected] site: www.bbsbarriers.com

H2 W2 NR No NR B Britpave Barrier Systems Ltd EN1317-5:2007Atrium CourtThe RingBracknellBerkshireRG12 1BWTel. 01344 393300email: [email protected] site: www.bbsbarriers.com

H2 W3 NR No NR B Britpave Barrier Systems Ltd EN1317-5:2007Atrium CourtThe RingBracknellBerkshireRG12 1BWTel. 01344 393300email: [email protected] site: www.bbsbarriers.com

N1 W5 0.9 Yes NA A Colas Ltd EN1317-5:2007+A2:2012NewcastleDerwenthaugh Industrial EstateDerwenthaugh RoadSwalwellNE16 3BQTel: 0191 414 6511email: [email protected] site: www.colas.co.uk

N2 W6 1.6 Yes NA A Colas Ltd EN1317-5:2007+A2:2012NewcastleDerwenthaugh Industrial EstateDerwenthaugh RoadSwalwellNE16 3BQTel: 0191 414 6511email: [email protected] site: www.colas.co.uk

N1 W4 0.6 Yes NA A Colas Ltd EN1317-5:2007+A2:2012NewcastleDerwenthaugh Industrial EstateDerwenthaugh RoadSwalwellNE16 3BQTel: 0191 414 6511email: [email protected] site: www.colas.co.uk

N2 W5 0.9 Yes NA B Colas Ltd EN1317-5:2007+A2:2012NewcastleDerwenthaugh Industrial EstateDerwenthaugh RoadSwalwellNE16 3BQTel: 0191 414 6511email: [email protected] site: www.colas.co.uk

Steel Step Barrier (SSB)

SMS+ (anchored every 12m)

SMS+ (unanchored)

Wide Variable Steel Step Barrier (WVSSB)

SMS+ (unanchored)

SMS+ (anchored every 12m) Note: Only permitted for use on

roads where road works are being

undertaken and a speed limit of less

than 50 mph is operative.

Wide Steel Step Barrier (WSSB)

Variable Steel Step Barrier (VSSB)

Wide Variable Concrete Step Barrier (WVCSB), Issue 5 Drawing file release

Safety Barriers (Part 1) 3 January 2015

Page 7: List of EN1317 Compliant RRS January 2015

Safety Barrier Name Containment Level Working Width Class Dynamic Deflection (m) Are DD and WW normalised? Vehicle Intrusion Class

Impact Severity Level

Name and Address of Promoter Version of EN1317-5 to which the system was CE marked

Comments

N2 W5 1.0 Yes NA B Colas Ltd EN1317-5:2007+A2:2012NewcastleDerwenthaugh Industrial EstateDerwenthaugh RoadSwalwellNE16 3BQTel: 0191 414 6511email: [email protected] site: www.colas.co.uk

H2 W2 0.0 Yes VI1 B DELTA BLOC UK Ltd EN1317-5:2007+A2:2012Unit A Fox WayTrinity Business ParkWaldorf WayWakefield, WF2 8EETel. 0845 30 40 705Fax. 0845 30 40 706email: [email protected] site: www.deltabloc.co.uk

H2 W2 0.0 Yes VI1 B DELTA BLOC UK Ltd EN1317-5:2007+A2:2012Unit A Fox WayTrinity Business ParkWaldorf WayWakefield, WF2 8EETel. 0845 30 40 705Fax. 0845 30 40 706email: [email protected] site: www.deltabloc.co.uk

H2 W2 - W4 0.0 Yes VI1 B DELTA BLOC UK Ltd EN1317-5:2007+A2:2012Unit A Fox WayTrinity Business ParkWaldorf WayWakefield, WF2 8EETel. 0845 30 40 705Fax. 0845 30 40 706email: [email protected] site: www.deltabloc.co.uk

H2 W2 0.0 Yes VI1 B DELTA BLOC UK Ltd EN1317-5:2007+A2:2012Unit A Fox WayTrinity Business ParkWaldorf WayWakefield, WF2 8EETel. 0845 30 40 705Fax. 0845 30 40 706email: [email protected] site: www.deltabloc.co.uk

H2 W2 0.0 Yes VI1 B DELTA BLOC UK Ltd EN1317-5:2007+A2:2012Unit A Fox WayTrinity Business ParkWaldorf WayWakefield, WF2 8EETel. 0845 30 40 705Fax. 0845 30 40 706email: [email protected] site: www.deltabloc.co.uk

H2 W2 0.0 Yes VI1 B DELTA BLOC UK Ltd EN1317-5:2007+A2:2012Unit A Fox WayTrinity Business ParkWaldorf WayWakefield, WF2 8EETel. 0845 30 40 705Fax. 0845 30 40 706email: [email protected] site: www.deltabloc.co.uk

H2 W2 0.0 Yes VI1 B DELTA BLOC UK Ltd EN1317-5:2007+A2:2012Unit A Fox WayTrinity Business ParkWaldorf WayWakefield, WF2 8EETel. 0845 30 40 705Fax. 0845 30 40 706email: [email protected] site: www.deltabloc.co.uk

H2 W2 0.0 Yes VI1 B DELTA BLOC UK Ltd EN1317-5:2007+A2:2012Unit A Fox WayTrinity Business ParkWaldorf WayWakefield, WF2 8EETel. 0845 30 40 705Fax. 0845 30 40 706email: [email protected] site: www.deltabloc.co.uk

SMS+ (anchored every 24m)

Delta Bloc EP80B-E In-situ concrete barrier

Delta Bloc EP80B-E Variable height

Delta Bloc EP80B-E Wide

Delta Bloc EP80Ba In-situ concrete barrier surface mounted on asphalt

Delta Bloc EP80Ba-LB In-situ concrete barrier surface mounted on asphalt - Low Base

Delta Bloc EP80Ba-EB In-situ concrete barrier surface mounted on asphalt - Elevated Base

Delta Bloc EP80Ba-VW In-situ concrete barrier surface mounted on asphalt - Variable Width

Delta Bloc EP80Ba-VH In-situ concrete barrier surface mounted on asphalt - Variable Height

Safety Barriers (Part 1) 4 January 2015

Page 8: List of EN1317 Compliant RRS January 2015

Safety Barrier Name Containment Level Working Width Class Dynamic Deflection (m) Are DD and WW normalised? Vehicle Intrusion Class

Impact Severity Level

Name and Address of Promoter Version of EN1317-5 to which the system was CE marked

Comments

H2 W3 0.2 Yes VI2 B DELTA BLOC UK Ltd EN1317-5:2007+A2:2012Unit A Fox WayTrinity Business ParkWaldorf WayWakefield, WF2 8EETel. 0845 30 40 705Fax. 0845 30 40 706email: [email protected] site: www.deltabloc.co.uk

N2 W3 0.4 NR NA B DELTA BLOC UK Ltd EN1317-5:2007+A1:2008Unit A Fox WayTrinity Business ParkWaldorf WayWakefield, WF2 8EETel. 0845 30 40 705Fax. 0845 30 40 706email: [email protected] site: www.deltabloc.co.uk

H1 W6 NR Yes NR B DELTA BLOC UK LtdUnit A Fox Way

N2 W4 NR NR NA B Trinity Business ParkWaldorf WayWakefield, WF2 8EETel. 0845 30 40 705Fax. 0845 30 40 706email: [email protected] site: www.deltabloc.co.uk

N2 W4 0.6 NR NA B DELTA BLOC UK Ltd EN1317-5:2007+A1:2008Unit A Fox WayTrinity Business ParkWaldorf WayWakefield, WF2 8EETel. 0845 30 40 705Fax. 0845 30 40 706email: [email protected] site: www.deltabloc.co.uk

N1 W4 NR NR NA A DELTA BLOC UK LtdUnit A Fox WayTrinity Business ParkWaldorf WayWakefield, WF2 8EETel. 0845 30 40 705Fax. 0845 30 40 706email: [email protected] site: www.deltabloc.co.uk

H1 W6 NR NR NR B DELTA BLOC UK LtdUnit A Fox WayTrinity Business ParkWaldorf WayWakefield, WF2 8EETel. 0845 30 40 705Fax. 0845 30 40 706email: [email protected] site: www.deltabloc.co.uk

H1 W4 0.6 NR NR B DELTA BLOC UK Ltd EN1317-5:2007+A1:2008Unit A Fox WayTrinity Business ParkWaldorf WayWakefield, WF2 8EETel. 0845 30 40 705Fax. 0845 30 40 706email: [email protected] site: www.deltabloc.co.uk

H1 W6 NR NR NR B DELTA BLOC UK LtdUnit A Fox WayTrinity Business ParkWaldorf WayWakefield, WF2 8EETel. 0845 30 40 705Fax. 0845 30 40 706email: [email protected] site: www.deltabloc.co.uk

H2 W1 0.1 NR NR B DELTA BLOC UK Ltd EN1317-5:2007+A1:2008Unit A Fox WayTrinity Business ParkWaldorf WayWakefield, WF2 8EETel. 0845 30 40 705Fax. 0845 30 40 706email: [email protected] site: www.deltabloc.co.uk

Delta Bloc DB65S/6m (K120S)

Delta Bloc DB80/4m (K120S)

Delta Bloc DB80/6m (K150S)

Delta Bloc DB80/4m (K150S)

Delta Bloc DB80/4m (K180)

Delta Bloc DB80/4m (K180)

Note: Only permitted for use on

roads where road works are being

undertaken and a speed limit of less

than 50 mph is operative.

Delta Bloc DB80/6m (K150S)

Delta Bloc DB80-E/6m (K150S)

Delta Bloc EP80Bs In-situ concrete barrier surface mounted on subbase/ compacted gravel

Safety Barriers (Part 1) 5 January 2015

Page 9: List of EN1317 Compliant RRS January 2015

Safety Barrier Name Containment Level Working Width Class Dynamic Deflection (m) Are DD and WW normalised? Vehicle Intrusion Class

Impact Severity Level

Name and Address of Promoter Version of EN1317-5 to which the system was CE marked

Comments

H2 W1 0.0 NR NR B DELTA BLOC UK Ltd EN1317-5:2007+A1:2008Unit A Fox WayTrinity Business ParkWaldorf WayWakefield, WF2 8EETel. 0845 30 40 705Fax. 0845 30 40 706email: [email protected] site: www.deltabloc.co.uk

H2 W3 NR NR NR B DELTA BLOC UK LtdUnit A Fox WayTrinity Business ParkWaldorf WayWakefield, WF2 8EETel. 0845 30 40 705Fax. 0845 30 40 706email: [email protected] site: www.deltabloc.co.uk

H2 W4 0.7 NR NR B DELTA BLOC UK Ltd EN1317-5:2007+A1:2008Unit A Fox WayTrinity Business ParkWaldorf WayWakefield, WF2 8EETel. 0845 30 40 705Fax. 0845 30 40 706email: [email protected] site: www.deltabloc.co.uk

H2 W4 NR NR NR B DELTA BLOC UK LtdUnit A Fox WayTrinity Business ParkWaldorf WayWakefield, WF2 8EETel. 0845 30 40 705Fax. 0845 30 40 706email: [email protected] site: www.deltabloc.co.uk

H2 W5 NR NR NR B DELTA BLOC UK LtdUnit A Fox WayTrinity Business ParkWaldorf WayWakefield, WF2 8EETel. 0845 30 40 705Fax. 0845 30 40 706email: [email protected] site: www.deltabloc.co.uk

H2 W5 NR NR NR A DELTA BLOC UK LtdUnit A Fox WayTrinity Business ParkWaldorf WayWakefield, WF2 8EETel. 0845 30 40 705Fax. 0845 30 40 706email: [email protected] site: www.deltabloc.co.uk

H2 W6 NR NR NR B DELTA BLOC UK LtdUnit A Fox WayTrinity Business ParkWaldorf WayWakefield, WF2 8EETel. 0845 30 40 705Fax. 0845 30 40 706email: [email protected] site: www.deltabloc.co.uk

H2 W6 NR NR NR C DELTA BLOC UK LtdUnit A Fox WayTrinity Business ParkWaldorf WayWakefield, WF2 8EETel. 0845 30 40 705Fax. 0845 30 40 706email: [email protected] site: www.deltabloc.co.uk

H4a W6 1.4 Yes VI9 B DELTA BLOC UK Ltd EN1317-5:2007+A2:2012Unit A Fox WayTrinity Business ParkWaldorf WayWakefield, WF2 8EETel. 0845 30 40 705Fax. 0845 30 40 706email: [email protected] site: www.deltabloc.co.uk

Delta Bloc DB80-F/6m (K180)

Delta Bloc DB80AS-A/6m (K120S)

Delta Bloc DB100S/6m (K220)

Delta Bloc DB80/6m (K180S)

Delta Bloc DB90 Step/6m (K220)

Delta Bloc DB100/6m (K280)

Delta Bloc DB80AS-F/6m (K120S)

Delta Bloc DB80AS-R/6m (K180)

The installation of safety barriers with an ASI Class of C must be with the agreement of the

Overseeing Organisation (refer

to TD19/06, Sections 3.6 and 3.7).

Delta Bloc DB80AS-E/6m (K180S)

Safety Barriers (Part 1) 6 January 2015

Page 10: List of EN1317 Compliant RRS January 2015

Safety Barrier Name Containment Level Working Width Class Dynamic Deflection (m) Are DD and WW normalised? Vehicle Intrusion Class

Impact Severity Level

Name and Address of Promoter Version of EN1317-5 to which the system was CE marked

Comments

H1 W6 1.4 Yes NR B Manufactured by: SGGT Strassenausstattungen GmbH EN1317-5:2007+A1:2008Distributed by: Ferrostrada (UK) LimitedVenlaw HouseBurston RoadHeywoodSouth NorfolkIP22 5SXWeb site: www.ferrostrada-uk.comTel: 01379 308 051Fax: 01379 308 053Email: [email protected]: Jason Ferro

N2 W4 0.7 Yes NA B Manufactured by: SGGT Strassenausstattungen GmbH EN1317-5:2007+A1:2008Distributed by: Ferrostrada (UK) Limited

H1/L1 W5 1.0 Yes NR B Venlaw House EN1317-5:2007+A1:2008Burston Road

H2/L2 W7 1.8 Yes NR B Heywood EN1317-5:2007+A1:2008South NorfolkIP22 5SXWeb site: www.ferrostrada-uk.comTel: 01379 308 051Fax: 01379 308 053Email: [email protected]: Jason Ferro

N2 W3 0.8 Yes NA A Manufactured by: Duero EN1317-5:2007+A1:2008Distributed by: Ferrostrada (UK) LimitedVenlaw HouseBurston RoadHeywoodSouth NorfolkIP22 5SXWeb site: www.ferrostrada-uk.comTel: 01379 308 051Fax: 01379 308 053Email: [email protected]: Jason Ferro

N2 W4 1.0 Yes NA A Manufactured by: Duero EN1317-5:2007+A1:2008Distributed by: Ferrostrada (UK) LimitedVenlaw HouseBurston RoadHeywoodSouth NorfolkIP22 5SXWeb site: www.ferrostrada-uk.comTel: 01379 308 051Fax: 01379 308 053Email: [email protected]: Jason Ferro

N2 W5 1.2 Yes NA A Manufactured by: Duero EN1317-5:2007+A1:2008Distributed by: Ferrostrada (UK) LimitedVenlaw HouseBurston RoadHeywoodSouth NorfolkIP22 5SXWeb site: www.ferrostrada-uk.comTel: 01379 308 051Fax: 01379 308 053Email: [email protected]: Jason Ferro

H1 W4 1.2 No NR A Manufactured by: Duero EN1317-5:2007+A1:2008Distributed by: Ferrostrada (UK) LimitedVenlaw HouseBurston RoadHeywoodSouth NorfolkIP22 5SXWeb site: www.ferrostrada-uk.comTel: 01379 308 051Fax: 01379 308 053Email: [email protected]: Jason Ferro

Duo Rail-KA

Duo Rail-KAB

DSS-N2W3 safety fence

DSS-N2W4 safety fence

DSS-N2W5 safety fence

DSS-H1W4 safety fence

Safety Barriers (Part 1) 7 January 2015

Page 11: List of EN1317 Compliant RRS January 2015

Safety Barrier Name Containment Level Working Width Class Dynamic Deflection (m) Are DD and WW normalised? Vehicle Intrusion Class

Impact Severity Level

Name and Address of Promoter Version of EN1317-5 to which the system was CE marked

Comments

H3 W2 0.5 No NR B Manufactured by: Duero EN1317-5:2007+A1:2008Distributed by: Ferrostrada (UK) LimitedVenlaw HouseBurston RoadHeywoodSouth NorfolkIP22 5SXWeb site: www.ferrostrada-uk.comTel: 01379 308 051Fax: 01379 308 053Email: [email protected]: Jason Ferro

N2 W2 0.7 No NA A Manufacturer: Marcegaglia Buildtech S.r.l EN1317-5:2007+A1:2008Distributed by: Ferrostrada (UK) LimitedVenlaw HouseBurston RoadHeywoodSouth Norfolk

IP22 5SXWeb site: www.ferrostrada-uk.comTel: 01379 308 051Fax: 01379 308 053Email: [email protected]: Jason Ferro

H1BL-MARC2008 H1 W3 0.7 No NR A Manufacturer: Marcegaglia Buildtech S.r.l EN1317-5:2007+A1:2008Distributed by: Ferrostrada (UK) LimitedVenlaw HouseBurston RoadHeywoodSouth NorfolkIP22 5SXWeb site: www.ferrostrada-uk.comTel: 01379 308 051Fax: 01379 308 053Email: [email protected]: Jason Ferro

H2 W6 1.9 No NR A Manufacturer: Marcegaglia Buildtech S.r.l EN1317-5:2007+A1:2008Distributed by: Ferrostrada (UK) LimitedVenlaw HouseBurston RoadHeywoodSouth NorfolkIP22 5SXWeb site: www.ferrostrada-uk.comTel: 01379 308 051Fax: 01379 308 053Email: [email protected]: Jason Ferro

H2 W4 1.1 No NR A Manufacturer: Marcegaglia Buildtech S.r.l EN1317-5:2007+A1:2008Distributed by: Ferrostrada (UK) LimitedVenlaw HouseBurston RoadHeywoodSouth NorfolkIP22 5SXWeb site: www.ferrostrada-uk.comTel: 01379 308 051Fax: 01379 308 053Email: [email protected]: Jason Ferro

H2 W3 0.9 Yes NR A Manufacturer: Marcegaglia Buildtech S.r.l EN1317-5:2007+A1:2008Distributed by: Ferrostrada (UK) LimitedVenlaw HouseBurston RoadHeywoodSouth NorfolkIP22 5SXWeb site: www.ferrostrada-uk.comTel: 01379 308 051Fax: 01379 308 053Email: [email protected]: Jason Ferro

DSS-H3W2 safety fence

H2BL-MARC2006

H2BL-MARC2007

H2BLW-MARC2011

N2W2-MARC2006

Safety Barriers (Part 1) 8 January 2015

Page 12: List of EN1317 Compliant RRS January 2015

Safety Barrier Name Containment Level Working Width Class Dynamic Deflection (m) Are DD and WW normalised? Vehicle Intrusion Class

Impact Severity Level

Name and Address of Promoter Version of EN1317-5 to which the system was CE marked

Comments

H2 W5 1.1 Yes NR B Manufacturer: Marcegaglia Buildtech S.r.l EN1317-5:2007+A1:2008Distributed by: Ferrostrada (UK) LimitedVenlaw HouseBurston RoadHeywoodSouth NorfolkIP22 5SXWeb site: www.ferrostrada-uk.comTel: 01379 308 051Fax: 01379 308 053Email: [email protected]: Jason Ferro

H2 W4 1.3 Yes NR A Manufacturer: Marcegaglia Buildtech S.r.l EN1317-5:2007+A1:2008Distributed by: Ferrostrada (UK) LimitedVenlaw HouseBurston RoadHeywoodSouth NorfolkIP22 5SXWeb site: www.ferrostrada-uk.comTel: 01379 308 051Fax: 01379 308 053Email: [email protected]: Jason Ferro

N2 W1 0.5 No NA B Manufactured by: SGGT Strassenausstattungen GmbH EN1317-5:2007+A1:2008Distributed by: Ferrostrada (UK) LimitedVenlaw HouseBurston RoadHeywoodSouth NorfolkIP22 5SXWeb site: www.ferrostrada-uk.comTel: 01379 308 051Fax: 01379 308 053Email: [email protected]: Jason Ferro

H2 W3 0.8 No NR B Ferrostrada (UK) Limited EN1317-5:2007+A1:2008Venlaw HouseBurston RoadHeywoodSouth NorfolkIP22 5SXWeb site: www.ferrostrada-uk.comTel: 01379 308 051Fax: 01379 308 053Email: [email protected]: Jason Ferro

H2 W2 0.5 No NR B Ferrostrada (UK) Limited EN1317-5:2007+A1:2008Venlaw HouseBurston RoadHeywoodSouth NorfolkIP22 5SXWeb site: www.ferrostrada-uk.comTel: 01379 308 051Fax: 01379 308 053Email: [email protected]: Jason Ferro

H2 W2 0.5 No NR B Ferrostrada (UK) Limited EN1317-5:2007+A1:2008Venlaw HouseBurston RoadHeywoodSouth NorfolkIP22 5SXWeb site: www.ferrostrada-uk.comTel: 01379 308 051Fax: 01379 308 053Email: [email protected]: Jason Ferro

H2 W4 0.5 No NR B Ferrostrada (UK) Limited EN1317-5:2007+A1:2008Venlaw HouseBurston RoadHeywoodSouth NorfolkIP22 5SXWeb site: www.ferrostrada-uk.comTel: 01379 308 051Fax: 01379 308 053Email: [email protected]: Jason Ferro

ESP Plus W1

ZB4-1

ZB4-2

ZB4-3

ZB4-4

PAB H2 BPC

PAB H2 CE

Safety Barriers (Part 1) 9 January 2015

Page 13: List of EN1317 Compliant RRS January 2015

Safety Barrier Name Containment Level Working Width Class Dynamic Deflection (m) Are DD and WW normalised? Vehicle Intrusion Class

Impact Severity Level

Name and Address of Promoter Version of EN1317-5 to which the system was CE marked

Comments

N2 W4 1.3 No NA A Ferrostrada (UK) Limited EN1317-5:2007+A1:2008Venlaw HouseBurston RoadHeywoodSouth NorfolkIP22 5SXWeb site: www.ferrostrada-uk.comTel: 01379 308 051Fax: 01379 308 053Email: [email protected]: Jason Ferro

N2 W4 1.3 No NA A Ferrostrada (UK) Limited EN1317-5:2007+A1:2008Venlaw HouseBurston RoadHeywoodSouth NorfolkIP22 5SXWeb site: www.ferrostrada-uk.comTel: 01379 308 051Fax: 01379 308 053Email: [email protected]: Jason Ferro

N2 W5 1.6 No NA A Ferrostrada (UK) Limited EN1317-5:2007+A1:2008Venlaw HouseBurston RoadHeywoodSouth Norfolk

IP22 5SXWeb site: www.ferrostrada-uk.comTel: 01379 308 051Fax: 01379 308 053Email: [email protected]: Jason Ferro

N2 W5 1.7 No NA A Ferrostrada (UK) Limited EN1317-5:2007+A1:2008Venlaw HouseBurston RoadHeywoodSouth NorfolkIP22 5SXWeb site: www.ferrostrada-uk.comTel: 01379 308 051Fax: 01379 308 053Email: [email protected]: Jason Ferro

N2 W4 NR No NA B Highway Care Ltd. EN1317-5:2007+A1:2008The Highlands

H2 W6 NR No NR B Detling Hill EN1317-5:2007+A1:2008Detling MaidstoneKentME14 3HTTel. 01622 734215Fax. 01622 735106email: [email protected] site: www.highwaycare.co.uk

N2 W2 0.7 No NA A Highway Care Ltd. EN1317-5:2007+A1:2008The HighlandsDetling HillDetling MaidstoneKentME14 3HTTel. 01622 734215Fax. 01622 735106email: [email protected] site: www.highwaycare.co.uk

H1 W4 1.2 No NR A Highway Care Ltd. EN1317-5:2007+A1:2008The Highlands

L1 W4 1.2 No NR A Detling Hill EN1317-5:2007+A1:2008Detling MaidstoneKentME14 3HTTel. 01622 734215Fax. 01622 735106email: [email protected] site: www.highwaycare.co.uk

ZS1-44

ZS1-83

ZS1-84

Quickchange Moveable Barrier (QMB) Permanent Application

Heintzmann Basic Barrier 1.33 Profil A

Heintzmann Basic Barrier 1.33 Profil A

ZS1-43

Safety Barriers (Part 1) 10 January 2015

Page 14: List of EN1317 Compliant RRS January 2015

Safety Barrier Name Containment Level Working Width Class Dynamic Deflection (m) Are DD and WW normalised? Vehicle Intrusion Class

Impact Severity Level

Name and Address of Promoter Version of EN1317-5 to which the system was CE marked

Comments

H1 W3 0.9 No NR A Highway Care Ltd. EN1317-5:2007+A1:2008The HighlandsDetling HillDetling MaidstoneKentME14 3HTTel. 01622 734215Fax. 01622 735106email: [email protected] site: www.highwaycare.co.uk

N2 W4 1.2 No NA A Highway Care Ltd. EN1317-5:2007+A1:2008The HighlandsDetling HillDetling MaidstoneKentME14 3HTTel. 01622 734215Fax. 01622 735106email: [email protected] site: www.highwaycare.co.uk

N2 W3 0.9 No NA A Highway Care Ltd. EN1317-5:2007+A1:2008The HighlandsDetling HillDetling MaidstoneKentME14 3HTTel. 01622 734215Fax. 01622 735106email: [email protected] site: www.highwaycare.co.uk

N2 W5 1.4 No NA A Highway Care Ltd. EN1317-5:2007+A1:2008The HighlandsDetling HillDetling MaidstoneKentME14 3HTTel. 01622 734215Fax. 01622 735106email: [email protected] site: www.highwaycare.co.uk

N2 W5 1.4 No NA A Highway Care Ltd. EN1317-5:2007+A1:2008The HighlandsDetling HillDetling MaidstoneKentME14 3HTTel. 01622 734215Fax. 01622 735106email: [email protected] site: www.highwaycare.co.uk

N2 W7 2.2 No NA A Highway Care Ltd. EN1317-5:2007+A1:2008The HighlandsDetling HillDetling MaidstoneKentME14 3HTTel. 01622 734215Fax. 01622 735106email: [email protected] site: www.highwaycare.co.uk

H2 NR No NR A Hill and Smith EN1317-5:2007Springvale Business and Industrial ParkBilstonWolverhamptonWest MidlandsWV14 0QLTel: 01902 499400Fax: 01902 499419Email: [email protected]: www.hill-smith.co.uk

With post centres at 1.6m the Working Width Class is: W5

Heintzmann Basic Barrier 1.33 Profil A

Nature Rail S4.2

Nature Rail S4.4

Heintzmann Basic Barrier 2.0 Profil A

Heintzmann Basic Barrier 2.0b Profil A

Heintzmann Basic Barrier 4.0 Profil A

Bri-Flex Double Sided Corrugated Beam and Wire Rope VRS

Safety Barriers (Part 1) 11 January 2015

Page 15: List of EN1317 Compliant RRS January 2015

Safety Barrier Name Containment Level Working Width Class Dynamic Deflection (m) Are DD and WW normalised? Vehicle Intrusion Class

Impact Severity Level

Name and Address of Promoter Version of EN1317-5 to which the system was CE marked

Comments

N2 NR No NA A Hill and Smith EN1317-5:2007Springvale Business and Industrial ParkBilstonWolverhampton

N2 NR No NA A West Midlands EN1317-5:2007WV14 0QLTel: 01902 499400Fax: 01902 499419

N2 NR No NA A Email: [email protected] EN1317-5:2007Web: www.hill-smith.co.uk

N2 NR No NA A Hill and Smith EN1317-5:2007Springvale Business and Industrial ParkBilstonWolverhampton

N2 NR No NA A West Midlands EN1317-5:2007WV14 0QLTel: 01902 499400Fax: 01902 499419Email: [email protected]: www.hill-smith.co.uk

N2 NR No NA B Hill and Smith EN1317-5:2007Springvale Business and Industrial ParkBilstonWolverhampton

N2 NR No NA B West Midlands EN1317-5:2007WV14 0QLTel: 01902 499400Fax: 01902 499419

N2 NR No NA B Email: [email protected] EN1317-5:2007Web: www.hill-smith.co.uk

H1 0.7 No NR B EN1317-5:2007+A1:2008

H1 NR No NR B EN1317-5:2007

H2 NR No NR B EN1317-5:2007

N2 NR No NA C Hill and Smith EN1317-5:2007Springvale Business and Industrial ParkBilstonWolverhampton

West MidlandsWV14 0QLTel: 01902 499400Fax: 01902 499419Email: [email protected]: www.hill-smith.co.uk

H2 NR No NR B Hill and Smith EN1317-5:2007+A1:2008Springvale Business and Industrial Park

W1 BilstonWolverhamptonWest MidlandsWV14 0QLTel: 01902 499400Fax: 01902 499419Email: [email protected]: www.hill-smith.co.uk

H2 W7 1.6 Yes VI7 A Pass and Co Barrier Systems GMBH EN1317-5:2007+A1:2008Dortmunderstrasse 857234 WilnsdorfGermanyTel: +49 (0)2739 4796-0Fax: +49 (0)2739 4796-110email: [email protected]

H1 W6 1.6 No NR A Pass and Co Barrier Systems GMBH EN1317-5:2007+A1:2008Dortmunderstrasse 857234 WilnsdorfGermanyTel: +49 (0)2739 4796-0Fax: +49 (0)2739 4796-110email: [email protected]

With post centres at 5.0m the Working Width Class is: W5

With post centres at 4.0m the Working Width Class is: W4

With post centres at 4.8m the Working Width Class is: W4

With post centres at 1.6m the Working Width Class is: W1

With post centres at 2.0m the Working Width Class is: W5

With post centres at 2.0m the Working Width Class is: W4

With post centres at 4.0m the Working Width Class is: W3

With post centres at 1.6m the Working Width Class is: W2

With post centres at 1.6m the Working Width Class is: W3

With post centres at 2.8m the Working Width Class is: W3

With post centres at 2.0m the Working Width Class is: W2

With post centres at 1.2m the Working Width Class is: W1

Flex-Beam PLUS Single Sided Corrugated Beam VRS

Flex-Beam PLUS-R Single Sided Corrugated Beam VRS

DDSP/1.33+SL

DDSP/4.0A

Hi Flex Safety Fence

Flex-Beam Double Sided Corrugated Beam VRS

Flex-Beam Single Sided Corrugated Beam VRS

The installation of safety barriers with an ASI Class of C must be with the agreement of the

Overseeing Organisation (refer

to TD19/06, Sections 3.6 and 3.7).

With post centres at 2.0m, Working Width Class is:

Safety Barriers (Part 1) 12 January 2015

Page 16: List of EN1317 Compliant RRS January 2015

Safety Barrier Name Containment Level Working Width Class Dynamic Deflection (m) Are DD and WW normalised? Vehicle Intrusion Class

Impact Severity Level

Name and Address of Promoter Version of EN1317-5 to which the system was CE marked

Comments

H1 W6 1.8 No NR A Pass and Co Barrier Systems GMBH EN1317-5:2007+A1:2008Dortmunderstrasse 857234 WilnsdorfGermanyTel: +49 (0)2739 4796-0Fax: +49 (0)2739 4796-110email: [email protected]

H1 W4 1.1 No NR A Pass and Co Barrier Systems GMBH EN1317-5:2007+A1:2008Dortmunderstrasse 857234 WilnsdorfGermanyTel: +49 (0)2739 4796-0Fax: +49 (0)2739 4796-110email: [email protected]

H1 W5 1.2 No NR A Pass and Co Barrier Systems GMBH EN1317-5:2007+A1:2008Dortmunderstrasse 857234 WilnsdorfGermanyTel: +49 (0)2739 4796-0Fax: +49 (0)2739 4796-110email: [email protected]

H1 W5 1.4 No NR A Pass and Co Barrier Systems GMBH EN1317-5:2007+A1:2008Dortmunderstrasse 857234 WilnsdorfGermanyTel: +49 (0)2739 4796-0Fax: +49 (0)2739 4796-110email: [email protected]

N2 W3 0.6 No NA B Pass and Co Barrier Systems GMBH EN1317-5:2007+A1:2008Dortmunderstrasse 857234 WilnsdorfGermanyTel: +49 (0)2739 4796-0Fax: +49 (0)2739 4796-110email: [email protected]

N2 W1 0.5 No NA B Pass and Co Barrier Systems GMBH EN1317-5:2007+A1:2008Dortmunderstrasse 857234 WilnsdorfGermanyTel: +49 (0)2739 4796-0Fax: +49 (0)2739 4796-110email: [email protected]

N2 W4 1.1 No NA A Pass and Co Barrier Systems GMBH EN1317-5:2007+A1:2008Dortmunderstrasse 857234 WilnsdorfGermanyTel: +49 (0)2739 4796-0Fax: +49 (0)2739 4796-110email: [email protected]

N2 W4 1.3 No NA A Pass and Co Barrier Systems GMBH EN1317-5:2007+A1:2008Dortmunderstrasse 857234 WilnsdorfGermanyTel: +49 (0)2739 4796-0Fax: +49 (0)2739 4796-110email: [email protected]

N2 W5 1.6 No NA A Pass and Co Barrier Systems GMBH EN1317-5:2007+A1:2008Dortmunderstrasse 857234 WilnsdorfGermanyTel: +49 (0)2739 4796-0Fax: +49 (0)2739 4796-110email: [email protected]

N2 W5 1.6 No NA A Pass and Co Barrier Systems GMBH EN1317-5:2007+A1:2008Dortmunderstrasse 857234 WilnsdorfGermanyTel: +49 (0)2739 4796-0Fax: +49 (0)2739 4796-110email: [email protected]

N2 W5 1.5 No NA A Pass and Co Barrier Systems GMBH EN1317-5:2007+A1:2008Dortmunderstrasse 857234 WilnsdorfGermanyTel: +49 (0)2739 4796-0Fax: +49 (0)2739 4796-110email: [email protected]

ESP/2.0B

ESP/4.0 UFS-EUS

ESP/4.0

EDSP/1.33 Bw

EDSP/2.0

ESP BOS (Baum-Objektschutz)

ESP Plus W1

ESP/2.0 Plus

ESP/2.0A

DDSP/4.0B

EDSP/1.33

Safety Barriers (Part 1) 13 January 2015

Page 17: List of EN1317 Compliant RRS January 2015

Safety Barrier Name Containment Level Working Width Class Dynamic Deflection (m) Are DD and WW normalised? Vehicle Intrusion Class

Impact Severity Level

Name and Address of Promoter Version of EN1317-5 to which the system was CE marked

Comments

N2 W6 1.9 No NA A Pass and Co Barrier Systems GMBH EN1317-5:2007+A1:2008Dortmunderstrasse 857234 WilnsdorfGermanyTel: +49 (0)2739 4796-0Fax: +49 (0)2739 4796-110email: [email protected]

H2 W4 1.0 No NR A Pass and Co Barrier Systems GMBH EN1317-5:2007+A1:2008Dortmunderstrasse 857234 WilnsdorfGermanyTel: +49 (0)2739 4796-0Fax: +49 (0)2739 4796-110email: [email protected]

H2 W4 0.7 No NR B Pass and Co Barrier Systems GMBH EN1317-5:2007+A1:2008Dortmunderstrasse 857234 WilnsdorfGermanyTel: +49 (0)2739 4796-0Fax: +49 (0)2739 4796-110email: [email protected]

H2 W4 0.9 No NR B Pass and Co Barrier Systems GMBH EN1317-5:2007+A1:2008Dortmunderstrasse 857234 WilnsdorfGermanyTel: +49 (0)2739 4796-0Fax: +49 (0)2739 4796-110email: [email protected]

H2 W4 0.8 No NR A Pass and Co Barrier Systems GMBH EN1317-5:2007+A1:2008Dortmunderstrasse 857234 WilnsdorfGermanyTel: +49 (0)2739 4796-0Fax: +49 (0)2739 4796-110email: [email protected]

H2 W4 0.7 No NR B Pass and Co Barrier Systems GMBH EN1317-5:2007+A1:2008Dortmunderstrasse 857234 WilnsdorfGermanyTel: +49 (0)2739 4796-0Fax: +49 (0)2739 4796-110email: [email protected]

H2 W4 0.7 No NR B Pass and Co Barrier Systems GMBH EN1317-5:2007+A1:2008Dortmunderstrasse 857234 WilnsdorfGermanyTel: +49 (0)2739 4796-0Fax: +49 (0)2739 4796-110email: [email protected]

H2 W4 0.7 No NR B Pass and Co Barrier Systems GMBH EN1317-5:2007+A1:2008Dortmunderstrasse 857234 WilnsdorfGermanyTel: +49 (0)2739 4796-0Fax: +49 (0)2739 4796-110email: [email protected]

H2 W4 1.1 No NR A Pass and Co Barrier Systems GMBH EN1317-5:2007+A1:2008Dortmunderstrasse 857234 WilnsdorfGermanyTel: +49 (0)2739 4796-0Fax: +49 (0)2739 4796-110email: [email protected]

H2 W4 0.7 No NR B Pass and Co Barrier Systems GMBH EN1317-5:2007+A1:2008Dortmunderstrasse 857234 WilnsdorfGermanyTel: +49 (0)2739 4796-0Fax: +49 (0)2739 4796-110email: [email protected]

H2 W4 1.1 No NR A Pass and Co Barrier Systems GMBH EN1317-5:2007+A1:2008Dortmunderstrasse 857234 WilnsdorfGermanyTel: +49 (0)2739 4796-0Fax: +49 (0)2739 4796-110email: [email protected]

Super Rail Eco MÜF

Super Rail

Super Rail BW

Super Rail doppelt

Super Rail Eco

Super Rail Eco 1A

Super Rail Eco doppelt - PA 2,00m

passco N2

SR Eco BW

SR Eco doppelt

SR light BW

Safety Barriers (Part 1) 14 January 2015

Page 18: List of EN1317 Compliant RRS January 2015

Safety Barrier Name Containment Level Working Width Class Dynamic Deflection (m) Are DD and WW normalised? Vehicle Intrusion Class

Impact Severity Level

Name and Address of Promoter Version of EN1317-5 to which the system was CE marked

Comments

H1 W3 0.8 No NR A Pass and Co Barrier Systems GMBH EN1317-5:2007+A1:2008Dortmunderstrasse 8

N2 W2 0.5 No NA A 57234 Wilnsdorf EN1317-5:2007+A1:2008GermanyTel: +49 (0)2739 4796-0Fax: +49 (0)2739 4796-110email: [email protected]

H1 W4 1.0 No NR A Pass and Co Barrier Systems GMBH EN1317-5:2007+A1:2008Dortmunderstrasse 857234 WilnsdorfGermanyTel: +49 (0)2739 4796-0Fax: +49 (0)2739 4796-110email: [email protected]

H2 W5 1.6 No NR B Pass and Co Barrier Systems GMBH EN1317-5:2007+A1:2008Dortmunderstrasse 857234 WilnsdorfGermanyTel: +49 (0)2739 4796-0Fax: +49 (0)2739 4796-110email: [email protected]

H2 W5 0.9 No NR B Pass and Co Barrier Systems GMBH EN1317-5:2007+A1:2008Dortmunderstrasse 857234 WilnsdorfGermanyTel: +49 (0)2739 4796-0Fax: +49 (0)2739 4796-110email: [email protected]

H2 W3 0.6 No NR B Pass and Co Barrier Systems GMBH EN1317-5:2007+A1:2008Dortmunderstrasse 857234 WilnsdorfGermanyTel: +49 (0)2739 4796-0Fax: +49 (0)2739 4796-110email: [email protected]

H2 W4 1.0 No NR A Pass and Co Barrier Systems GMBH EN1317-5:2007+A1:2008Dortmunderstrasse 857234 WilnsdorfGermanyTel: +49 (0)2739 4796-0Fax: +49 (0)2739 4796-110email: [email protected]

H2 W3 0.5 Yes NR B PEIS Maskinfabrik A/S EN1317-5:2007+A2:2012Hobrovej 7179230 SvenstrupDenmarkTel: +45 98 38 18 50email: [email protected]

N2 W3 0.5 No NA B REBLOC GmbH EN1317-5:2007+A1:2008Weinerstrasse 662Gars am Kamp3571 AustriaTel. +43(2985)30922-2902Fax. +43(2985)30922-2901email: [email protected] site: www.rebloc.com

H1 W4 0.8 No NR B REBLOC GmbH EN1317-5:2007+A1:2008Weinerstrasse 662Gars am Kamp3571 AustriaTel. +43(2985)30922-2902Fax. +43(2985)30922-2901email: [email protected] site: www.rebloc.com

H2 W5 1.0 No NR B REBLOC GmbH EN1317-5:2007+A1:2008Weinerstrasse 662Gars am Kamp3571 AustriaTel. +43(2985)30922-2902Fax. +43(2985)30922-2901email: [email protected] site: www.rebloc.com

H2 W1 0.0 Yes VI2 B REBLOC GmbH EN1317-5:2007+A2:2012Weinerstrasse 662Gars am Kamp3571 AustriaTel. +43(2985)30922-2902Fax. +43(2985)30922-2901email: [email protected] site: www.rebloc.com

Super Rail ES/1,0

Super Rail ES/1,33

Super Rail light

Super Rail light auf BW

Super Rail VZB

SuperRail Eco auf Bauwerk

PEIS CE 100

REBLOC RB80_8_H2/W5

REBLOC RB80A_8_H2/W1

REBLOC RB80_8_N2/W3

REBLOC RB80_8_H1/W4

Safety Barriers (Part 1) 15 January 2015

Page 19: List of EN1317 Compliant RRS January 2015

Safety Barrier Name Containment Level Working Width Class Dynamic Deflection (m) Are DD and WW normalised? Vehicle Intrusion Class

Impact Severity Level

Name and Address of Promoter Version of EN1317-5 to which the system was CE marked

Comments

H2 W5 0.9 Yes VI5 B REBLOC GmbH EN1317-5:2007+A2:2012Weinerstrasse 662Gars am Kamp3571 AustriaTel. +43(2985)30922-2902Fax. +43(2985)30922-2901email: [email protected] site: www.rebloc.com

H2 W4 0.3 Yes VI2 B REBLOC GmbH EN1317-5:2007+A2:2012Weinerstrasse 662Gars am Kamp3571 AustriaTel. +43(2985)30922-2902Fax. +43(2985)30922-2901email: [email protected] site: www.rebloc.com

N2 W7 2.1 No NA A Rondino EN1317-5:2007+A1:2008Rue de l’IndustrieB.P.195 - Savigneux42604 MONTBRISONFRANCETel: (+33) 4 77 96 29 70 .Fax: (+33) 4 77 96 29 90/95email: [email protected]

N2 W6 1.7 No NA A Rondino EN1317-5:2007+A1:2008Rue de l’IndustrieB.P.195 - Savigneux42604 MONTBRISONFRANCETel: (+33) 4 77 96 29 70 .Fax: (+33) 4 77 96 29 90/95email: [email protected]

H2 W4 1.0 No NR B Rondino EN1317-5:2007+A1:2008Rue de l’IndustrieB.P.195 - Savigneux42604 MONTBRISONFRANCETel: (+33) 4 77 96 29 70 .Fax: (+33) 4 77 96 29 90/95email: [email protected]

N2 W7 2.2 No NA A Rondino EN1317-5:2007+A1:2008Rue de l’IndustrieB.P.195 - Savigneux42604 MONTBRISONFRANCETel: (+33) 4 77 96 29 70 .Fax: (+33) 4 77 96 29 90/95email: [email protected]

N2 W5 1.6 No NA A Rondino EN1317-5:2007+A1:2008Rue de l’IndustrieB.P.195 - Savigneux42604 MONTBRISONFRANCETel: (+33) 4 77 96 29 70 .Fax: (+33) 4 77 96 29 90/95email: [email protected]

N2 W4 1.0 No NA A SafeRoad UK Ltd. EN1317-5:2007+A1:2008Dragonby Vale

H1 W5 1.2 No NR A Enterprise Park EN1317-5:2007+A1:2008Manaberg WayScunthorpeNorth LincolnshireDN15 8XFTel. 01724 289119email: [email protected]

N2 1.3 No NA A SafeRoad UK Ltd. EN1317-5:2007+A1:2008Dragonby ValeEnterprise ParkManaberg WayScunthorpeNorth LincolnshireDN15 8XFTel. 01724 289119email: [email protected]

N2 W4 1.3 No NA A SafeRoad UK Ltd. EN1317-5:2007+A1:2008Dragonby ValeEnterprise ParkManaberg WayScunthorpeNorth LincolnshireDN15 8XFTel. 01724 289119email: [email protected]

With post centres at 4.0m the Working Width Class is: W4

GH2

Birsta 1P Guardrail

G4M+

G2M+

Whilst the name of the system is 'Birsta

W2', it is a W4 system

ESP 2.0 (A)

MegaRail (Birsta W2)

G4M

G2M

REBLOC NB100/300_8_H2/W4

REBLOC RB100_2_H2/W5

Safety Barriers (Part 1) 16 January 2015

Page 20: List of EN1317 Compliant RRS January 2015

Safety Barrier Name Containment Level Working Width Class Dynamic Deflection (m) Are DD and WW normalised? Vehicle Intrusion Class

Impact Severity Level

Name and Address of Promoter Version of EN1317-5 to which the system was CE marked

Comments

N2 W5 1.6 No NA A SafeRoad UK Ltd. EN1317-5:2007+A1:2008Dragonby ValeEnterprise ParkManaberg WayScunthorpeNorth LincolnshireDN15 8XFTel. 01724 289119email: [email protected]

N2 W1 0.5 No NA B SafeRoad UK Ltd. EN1317-5:2007+A1:2008Dragonby ValeEnterprise ParkManaberg WayScunthorpeNorth LincolnshireDN15 8XFTel. 01724 289119email: [email protected]

H1 W2 0.6 Yes NR A SafeRoad UK Ltd. EN1317-5:2007+A2:2012Dragonby ValeEnterprise ParkManaberg WayScunthorpeNorth LincolnshireDN15 8XFTel. 01724 289119email: [email protected]

H2 W3 0.8 No NR B SafeRoad UK Ltd. EN1317-5:2007+A1:2008Dragonby ValeEnterprise ParkManaberg WayScunthorpeNorth LincolnshireDN15 8XFTel. 01724 289119email: [email protected]

H2 W5 1.6 No NR A SafeRoad UK Ltd. EN1317-5:2007+A1:2008Dragonby ValeEnterprise ParkManaberg WayScunthorpeNorth LincolnshireDN15 8XFTel. 01724 289119email: [email protected]

H2 W4 0.6 No NR B SafeRoad UK Ltd. EN1317-5:2007+A1:2008Dragonby ValeEnterprise ParkManaberg WayScunthorpeNorth LincolnshireDN15 8XFTel. 01724 289119email: [email protected]

N2 W3 1.0 No NA B SafeRoad UK Ltd. EN1317-5:2007+A1:2008Dragonby ValeEnterprise ParkManaberg WayScunthorpeNorth LincolnshireDN15 8XFTel. 01724 289119email: [email protected]

H2 W4 1.0 Yes NR A SafeRoad UK Ltd. EN1317-5:2007+A1:2008Dragonby ValeEnterprise ParkManaberg WayScunthorpeNorth LincolnshireDN15 8XFTel. 01724 289119email: [email protected]

H1 W3 0.7 Yes NR A SafeRoad UK Ltd. EN1317-5:2007+A1:2008Dragonby ValeEnterprise ParkManaberg WayScunthorpeNorth LincolnshireDN15 8XFTel. 01724 289119email: [email protected]

MegaRail ec 4.4

MegaRail db (Double Sided)

MegaRail ek

ESP 4.0 (A & B)

ESP Plus W1

MegaRail bs

MegaRail bw

MegaRail e

Safety Barriers (Part 1) 17 January 2015

Page 21: List of EN1317 Compliant RRS January 2015

Safety Barrier Name Containment Level Working Width Class Dynamic Deflection (m) Are DD and WW normalised? Vehicle Intrusion Class

Impact Severity Level

Name and Address of Promoter Version of EN1317-5 to which the system was CE marked

Comments

H1 W4 1.2 Yes VI4 A SafeRoad UK Ltd. EN1317-5:2007+A2:2012Dragonby ValeEnterprise ParkManaberg WayScunthorpeNorth LincolnshireDN15 8XFTel. 01724 289119email: [email protected]

N2 W3 0.9 Yes NA A SafeRoad UK Ltd. EN1317-5:2007+A2:2012Dragonby ValeEnterprise ParkManaberg WayScunthorpeNorth LincolnshireDN15 8XFTel. 01724 289119email: [email protected]

H1 W3 0.9 Yes VI7 A SafeRoad UK Ltd. EN1317-5:2007+A2:2012Dragonby ValeEnterprise ParkManaberg WayScunthorpeNorth LincolnshireDN15 8XFTel. 01724 289119email: [email protected]

H1 W3 0.7 Yes VI4 A SafeRoad UK Ltd. EN1317-5:2007+A2:2012Dragonby ValeEnterprise ParkManaberg WayScunthorpeNorth LincolnshireDN15 8XFTel. 01724 289119email: [email protected]

H2 W2 0.6 Yes VI2 A SafeRoad UK Ltd. EN1317-5:2007+A2:2012Dragonby ValeEnterprise ParkManaberg WayScunthorpeNorth LincolnshireDN15 8XFTel. 01724 289119email: [email protected]

N2 W3 0.8 Yes NA A SafeRoad UK Ltd. EN1317-5:2007+A2:2012Dragonby ValeEnterprise ParkManaberg WayScunthorpeNorth LincolnshireDN15 8XFTel. 01724 289119email: [email protected]

N2 W3 0.9 Yes NA A SafeRoad UK Ltd. EN1317-5:2007+A2:2012Dragonby ValeEnterprise ParkManaberg WayScunthorpeNorth LincolnshireDN15 8XFTel. 01724 289119email: [email protected]

N2 W4 1.2 Yes NA A SafeRoad UK Ltd. EN1317-5:2007+A2:2012Dragonby ValeEnterprise ParkManaberg WayScunthorpeNorth LincolnshireDN15 8XFTel. 01724 289119email: [email protected]

N2 W2 0.7 Yes NA A SafeRoad UK Ltd. EN1317-5:2007+A1:2008Dragonby ValeEnterprise ParkManaberg WayScunthorpeNorth LincolnshireDN15 8XFTel. 01724 289119email: [email protected]

MegaRail eb

MegaRail eb

MegaRail sk

VIK CC4-W3

MegaRail em

MegaRail es

MegaRail en

MegaRail eb

Vik CC2-W3

Safety Barriers (Part 1) 18 January 2015

Page 22: List of EN1317 Compliant RRS January 2015

Safety Barrier Name Containment Level Working Width Class Dynamic Deflection (m) Are DD and WW normalised? Vehicle Intrusion Class

Impact Severity Level

Name and Address of Promoter Version of EN1317-5 to which the system was CE marked

Comments

H2 W4 1.0 No NR B SafeRoad UK Ltd. EN1317-5:2007+A1:2008Dragonby Vale

H3 W4 0.8 Yes NR B Enterprise Park EN1317-5:2007+A1:2008Manaberg WayScunthorpeNorth LincolnshireDN15 8XFTel. 01724 289119email: [email protected]

H1 W4 1.1 No NR A SafeRoad UK Ltd. EN1317-5:2007+A1:2008Dragonby Vale

N2 W4 1.1 No NA A Enterprise Park EN1317-5:2007+A1:2008Manaberg WayScunthorpeNorth LincolnshireDN15 8XFTel. 01724 289119email: [email protected]

H2 W2 0.4 No NR B SafeRoad UK Ltd. EN1317-5:2007+A1:2008Dragonby ValeEnterprise ParkManaberg WayScunthorpeNorth LincolnshireDN15 8XFTel. 01724 289119email: [email protected]

H1 W3 0.8 No NR A SafeRoad UK Ltd. EN1317-5:2007+A1:2008Dragonby ValeEnterprise ParkManaberg WayScunthorpeNorth LincolnshireDN15 8XFTel. 01724 289119email: [email protected]

N2 NR No NA A Tata Steel Construction Products EN1317-5:2007Llanwern WorksNewportSouth Wales

N2 NR No NA A NP19 4QZ EN1317-5:2007Tel. 01633 290011 email: [email protected]

N2 NR No NA B EN1317-5:2007

N2 NR NR NA C Tata Steel Tubes EuropePO Box 101Weldon RoadCorby

N2 NR NR NA B NorthantsNN17 5UATel. 01536 402121email:[email protected]

N2 NR NR NA B

N2 NR NR NA B Tata Steel Tubes EuropePO Box 101Weldon RoadCorby

N2 NR NR NA B NorthantsNN17 5UATel. 01536 402121email:[email protected]

With post centres at 4.0m the Working Width Class is: W3

Protect 365 N2 Safety Fence (socketed)

Steel Step Barrier

Super Rail ES 1.0

With post centres at 2.0m the Working Width Class is: W1

Protect 365 N2 Safety Fence (surface mounted)

MegaRail s

MegaRail sl

With post centres at 4 and 4.375m the Working Width Class is: W3

With post centres at 3.0m the Working Width Class is: W2

With post centres at 2.0m the Working Width Class is: W1

With post centres at 3.5m the Working Width Class is: W4

With post centres at 3.2m the Working Width Class is: W3

With post centres at 3.0m the Working Width Class is: W3

Tata Steel Vetex N2 Single Sided Safety Barrier

Safety Barriers (Part 1) 19 January 2015

Page 23: List of EN1317 Compliant RRS January 2015

Safety Barrier Name Containment Level Working Width Class Dynamic Deflection (m) Are DD and WW normalised? Vehicle Intrusion Class

Impact Severity Level

Name and Address of Promoter Version of EN1317-5 to which the system was CE marked

Comments

N2 W7 2.3 No NA A Manufacturer : EN1317-5:2007+A1:2008TERTULes bois de Tertu61160 VILLEDIEU LES BAILLEUL FRANCETel : +33 2 33 36 11 02Fax : +33 2 33 39 28 75email: [email protected]

Distributor: Ferrostrada (UK) LimitedVenlaw HouseBurston RoadHeywoodSouth NorfolkIP22 5SXWeb site: www.ferrostrada-uk.comTel: 01379 308 051Fax: 01379 308 053Email: [email protected]: Jason Ferro

N2 W5 1.5 No NA A Manufacturer : EN1317-5:2007+A1:2008TERTULes bois de Tertu61160 VILLEDIEU LES BAILLEUL FRANCETel : +33 2 33 36 11 02Fax : +33 2 33 39 28 75email: [email protected]: Ferrostrada (UK) LimitedVenlaw HouseBurston RoadHeywoodSouth NorfolkIP22 5SXWeb site: www.ferrostrada-uk.comTel: 01379 308 051Fax: 01379 308 053Email: [email protected]: Jason Ferro

N2 W6 1.8 No NA A Manufacturer : EN1317-5:2007+A1:2008TERTULes bois de Tertu61160 VILLEDIEU LES BAILLEUL FRANCETel : +33 2 33 36 11 02Fax : +33 2 33 39 28 75email: [email protected]: Ferrostrada (UK) LimitedVenlaw HouseBurston RoadHeywoodSouth NorfolkIP22 5SXWeb site: www.ferrostrada-uk.comTel: 01379 308 051Fax: 01379 308 053Email: [email protected]: Jason Ferro

N2 W4 0.8 No NA B Manufacturer : EN1317-5:2007+A1:2008TERTU

H2 W4 0.8 No NA B Les bois de Tertu EN1317-5:2007+A1:200861160 VILLEDIEU LES BAILLEUL FRANCETel : +33 2 33 36 11 02Fax : +33 2 33 39 28 75email: [email protected]: Ferrostrada (UK) LimitedVenlaw HouseBurston RoadHeywoodSouth NorfolkIP22 5SXWeb site: www.ferrostrada-uk.comTel: 01379 308 051Fax: 01379 308 053Email: [email protected]: Jason Ferro

T22 4M

T18 4M

T18 4MS2

T40

Safety Barriers (Part 1) 20 January 2015

Page 24: List of EN1317 Compliant RRS January 2015

Safety Barrier Name Containment Level Working Width Class Dynamic Deflection (m) Are DD and WW normalised? Vehicle Intrusion Class

Impact Severity Level

Name and Address of Promoter Version of EN1317-5 to which the system was CE marked

Comments

N2 W6 NR No NA A Trinity Highway Products International EN1317-5:2007Crown House

H2 W8 NR No NR A Crown Street EN1317-5:2007IpswichSuffolkIP1 3HSTel. 01473 22 11 05Fax: 01473 22 11 06email: [email protected] site: www.energyabsorption.com

END OF SAFETY BARRIER SECTION - RETURN TO CONTENTS

Vulcan Safety Barrier

Safety Barriers (Part 1) 21 January 2015

Page 25: List of EN1317 Compliant RRS January 2015

SAFETY BARRIERS (PART 2)

Safety Barrier Name Containment Level Working Width Class Dynamic Deflection (m) Are DD and WW normalised? Vehicle Intrusion Class

Impact Severity Level

Name and Address of Promoter Comments

Higher Vertical Concrete Barrier (HVCB)

H4a W5 C Please contact an appropriate Manufacturer/ Contractor for details including information on construction.

The installation of safety barriers with an ASI Class of C must be

with the agreement of the Overseeing Organisation (refer to

TD19/06, Sections 3.6 and 3.7).

Vertical Concrete Barrier (VCB)

N2 W1 C Please contact an appropriate Manufacturer/ Contractor for details including information on construction.

The installation of safety barriers with an ASI Class of C must be

with the agreement of the Overseeing Organisation (refer to

TD19/06, Sections 3.6 and 3.7).

Double Rail Open Box Beam (DROBB)

H1 W4 B Please contact any of the Promoters listed below for details including information on construction, connections and transitions.

N2 With post centres at 1.2m the Working Width Class is: W4

B Please contact any of the Promoters listed below for details including information on construction, connections and transitions.

With post centres at 2.4m the Working Width Class is: W5

B

N2 With post centres at 1.2m the Working Width Class is: W4

B Please contact any of the Promoters listed below for details including information on construction, connections and transitions.

With post centres at 2.4m then the Working Width Class is: W5

B

Single Sided Tensioned Corrugated Beam (SSTCB)

N2 With post centres at 3.2m the Working Width Class is: W6

A Please contact any of the Promoters listed below for details including information on construction, connections and transitions.

Double Sided Tensioned Corrugated Beam (DSTCB)

N2 With post centres at 3.2m the Working Width Class is: W6

Unknown Please contact any of the Promoters listed below for details including information on construction, connections and transitions.

The following Safety Barriers have been successfully tested to meet the requirements of BS EN 1317 -1 and -2, but are not CE marked, and therefore can only be used on the Highways Agency Trunk Road Network for repair schemes or unless a case can be made within a Departure from Standard application.

Essential characteristic information only is provided and confirmation is required that the system selected complies fully with all HA contractual conditions and requirements as detailed in the DMRB, MCHW, and any contract specific or site specific documentation.

The Safety Barriers shall comply with the manufacturer's Specification, component descriptions and Installation procedures. Further information on Impact Severity Levels for the product and copies of documents and drawings can be obtained from the Promoter.

NA: Not ApplicableNR: Not Reported

Single Sided Open Box Beam (SSOBB)

Double Sided Open Box Beam (DSOBB)

Safety Barriers (Part 2) 22 January 2015

Page 26: List of EN1317 Compliant RRS January 2015

Clipstone Services Limited Hill and Smith Tata Steel Construction ProductsUnits J & K Springvale Business and Industrial Park Llanwern WorksClipstone Holding Centre Bilston NewportClipstone Village Wolverhampton South WalesMansfield West Midlands Tel. 01633 290011 Nottinghamshire WV14 0QL email: [email protected] 9AP Tel: 01902 499400Tel. 01623 420188 Fax: 01902 499419 Tata Steel Tubes Europe

Email: [email protected] PO Box 101CPC Fencing Services Ltd Web: www.hill-smith.co.uk Weldon RoadUnit 5 Joiners Court CorbyTorworth SafeRoad UK Ltd. NorthantsRetford Dragonby Vale NN17 5UANotts Enterprise Park Tel. 01536 402121DN22 8NW Manaberg Way email:[email protected] 01777 817 700 ScunthorpeFax 01777 817 272 North Lincolnshire Versco Ltd.Email: [email protected] DN15 8XF 5 Lock Lane

Tel. 01724 289119 ThorneEurorail Crash Barriers Ltd email: [email protected] DoncasterUnit 5 Joiners Court DN8 5ETTorworth Tel: 01405 818458Retford email: [email protected] 8NWTel 01777 817 700Fax 01777 817 272Email: [email protected]

END OF SAFETY BARRIER SECTION - RETURN TO CONTENTS

The Promoters for the above Double Rail Open Box Beam (DROBB), Single Sided Open Box Beam (SSOBB), Double Sided Open Box Beam (DSOBB), Single Sided Tensioned Corrugated Beam (SSTCB) and Double Sided Tensioned Corrugated Beam (DSTCB) are listed below. Please contact these Promoters for all enquiries concerning these safety barrier systems and associated connections and transitions and detailed and general arrangement drawings.

Safety Barriers (Part 2) 23 January 2015

Page 27: List of EN1317 Compliant RRS January 2015

TEMPORARY SAFETY BARRIERS

Temporary Safety Barrier Name Containment Level Working Width Class Impact Severity Level

Name and Address of Promoter Comments

H1 W7 B Ardee Precast Concrete LimitedTown ParksArdeeCo. LouthIrelandTel. +353 41 6856372Fax. +353 41 6857216email: [email protected] Web Site: www.ardeeprecastconcrete.com

N2 W5 C Ardee Precast Concrete LimitedTown ParksArdeeCo. LouthIrelandTel. +353 41 6856372Fax. +353 41 6857216email: [email protected] Web Site: www.ardeeprecastconcrete.com

N1 W3 A Ardee Precast Concrete LimitedTown ParksArdeeCo. LouthIrelandTel. +353 41 6856372Fax. +353 41 6857216email: [email protected] Web Site: www.ardeeprecastconcrete.comAsset International (A Division of Hill and Smith)Springvale AvenueBilstonWolverhampton

N2 W6 B WV14 0QLTel. 01902 499402

H2 W8 B Fax. 01902 402104email: [email protected]

L2 W8 B Web Site: www.asset-vrs.co.uk

The installation of temporary safety barriers with an ASI

Class of C must be with the agreement of the Overseeing

Organisation (refer to TD19/06, Sections 8.5 and

8.6).

System Spengler Transportable Double Sided Precast Concrete Barrier (height 0.81m)

Note: For a different installation length please contact the Promoter for

information concerning the Working Width of the system.

Varioguard Double Sided Safety Barrier - SYSTEM No. 1

For a tested length of 60m between end anchors, and anchored in accordance with the EN1317 compliant test,

the working width class shall be:

System Spengler Transportable Double Sided Precast Concrete Barrier (height 0.81m)

System Spengler Transportable Double Sided Precast Concrete Barrier (height 0.81m)

Note: Only permitted for use on roads where road works are being undertaken and a speed limit of less than 50

mph is operative.

The following Temporary Safety Barriers have been successfully tested to meet the requirements of BS EN 1317 -1 and -2 and have been accepted for use on the Highways Agency Trunk Road Network for the Containment Performance Class and Working Width Class stated below.

Essential characteristic information only is provided and confirmation is required that the system selected complies fully with all HA contractual conditions and requirements as detailed in the DMRB, MCHW, and any contract specific or site specific documentation.

The Temporary Safety Barriers shall comply with the manufacturer's Specification, component descriptions and Installation procedures. Further information on Impact Severity Levels for the product and copies of documents and drawings can be obtained from the Promoter.

Temporary Safety Barriers 24 January 2015

Page 28: List of EN1317 Compliant RRS January 2015

Temporary Safety Barrier Name Containment Level Working Width Class Impact Severity Level

Name and Address of Promoter Comments

Asset International (A Division of Hill and Smith)Springvale AvenueBilstonWolverhampton

N2 W6 B WV14 0QLTel. 01902 499402

H2 W8 B Fax. 01902 402104email: [email protected]

L2 W8 B Web Site: www.asset-vrs.co.ukH1 W5 B Asset International (A Division of Hill and Smith)

Springvale AvenueBilstonWolverhamptonWV14 0QLTel. 01902 499402Fax. 01902 402104email: [email protected] Site: www.asset-vrs.co.ukAsset International (A Division of Hill and Smith)Springvale Avenue

BilstonWolverhampton

N2 W5 B WV14 0QLTel. 01902 499402Fax. 01902 402104email: [email protected] Site: www.asset-vrs.co.ukAsset International (A Division of Hill and Smith)Springvale AvenueBilstonWolverhampton

N2 W4 B WV14 0QLTel. 01902 499402Fax. 01902 402104email: [email protected] Site: www.asset-vrs.co.uk

N2 W6 B Asset International (A Division of Hill and Smith)Springvale AvenueBilstonWolverhamptonWV14 0QLTel. 01902 499402

Fax. 01902 402104email: [email protected] Site: www.asset-vrs.co.uk

N2 W6 B Asset International (A Division of Hill and Smith)Springvale AvenueBilstonWolverhamptonWV14 0QLTel. 01902 499402Fax. 01902 402104email: [email protected] Site: www.asset-vrs.co.uk

For a tested length of 68m between end anchors, and anchored in accordance with the EN1317 compliant test,

the working width class shall be:

Varioguard 'Quick Joint' Steel Safety Barrier - SYSTEM No. 2

Note: For a different installation length please contact the Promoter for

information concerning the Working Width of the system.

SOLOGUARD Emergency and Maintenance Crossing Point System

For a tested length of 68m between end anchors, and anchored in accordance with the EN1317 compliant test,

the working width class shall be:

Varioguard 'Quick Joint' Double Sided Steel Safety Barrier - SYSTEM No. 5

Note: For a different installation length please contact the Promoter for

information concerning the Working Width of the system.

Note: For a different installation length please contact the Promoter for

information concerning the Working Width of the system.

For a tested length of 88m between end anchors, and anchored in accordance with the EN1317 compliant test,

the working width class shall be:

Varioguard Double Sided Steel Safety Barrier - SYSTEM No. 3

Varioguard QM Safety Barrier System - SYSTEM No. 6 - pre move

Varioguard QM Safety Barrier System - SYSTEM No. 6 - moved

Temporary Safety Barriers 25 January 2015

Page 29: List of EN1317 Compliant RRS January 2015

Temporary Safety Barrier Name Containment Level Working Width Class Impact Severity Level

Name and Address of Promoter Comments

N2 W6 B Asset International (A Division of Hill and Smith)Springvale AvenueBilstonWolverhampton

WV14 0QLTel. 01902 499402Fax. 01902 402104email: [email protected] Site: www.asset-vrs.co.uk

N2 W2 B Asset International (A Division of Hill and Smith)Springvale AvenueBilstonWolverhampton

WV14 0QLTel. 01902 499402Fax. 01902 402104email: [email protected] Site: www.asset-vrs.co.uk

N1 W4 A DELTA BLOC UK LtdUnit A Fox WayTrinity Business ParkWaldorf WayWakefield, WF2 8EETel. 0845 30 40 705Fax. 0845 30 40 706email: [email protected] site: www.deltabloc.co.uk

N2 W3 B DELTA BLOC UK LtdUnit A Fox WayTrinity Business ParkWaldorf WayWakefield, WF2 8EETel. 0845 30 40 705Fax. 0845 30 40 706email: [email protected] site: www.deltabloc.co.uk

N2 W3 B DELTA BLOC UK LtdUnit A Fox WayTrinity Business ParkWaldorf WayWakefield, WF2 8EETel. 0845 30 40 705Fax. 0845 30 40 706email: [email protected] site: www.deltabloc.co.uk

N2 W4 B DELTA BLOC UK LtdUnit A Fox WayTrinity Business ParkWaldorf WayWakefield, WF2 8EETel. 0845 30 40 705Fax. 0845 30 40 706email: [email protected] site: www.deltabloc.co.uk

ZoneGuard System 1

ZoneGuard System No. 2 - pinned at 12m centres

Note: Only permitted for use on roads where road works are being undertaken and a speed limit of less than 50

mph is operative.

Delta Bloc DB80/4m (K180)

Delta Bloc DB80/6m (K150S)

Delta Bloc DB65S/6m (K120S)

Delta Bloc DB80E (K150S)

Temporary Safety Barriers 26 January 2015

Page 30: List of EN1317 Compliant RRS January 2015

Temporary Safety Barrier Name Containment Level Working Width Class Impact Severity Level

Name and Address of Promoter Comments

N2 W4 B DELTA BLOC UK LtdUnit A Fox WayTrinity Business ParkWaldorf WayWakefield, WF2 8EETel. 0845 30 40 705Fax. 0845 30 40 706email: [email protected] site: www.deltabloc.co.uk

N2 W5 A DELTA BLOC UK LtdUnit A Fox WayTrinity Business ParkWaldorf WayWakefield, WF2 8EETel. 0845 30 40 705Fax. 0845 30 40 706email: [email protected] site: www.deltabloc.co.uk

H1 W4 B DELTA BLOC UK LtdUnit A Fox WayTrinity Business ParkWaldorf WayWakefield, WF2 8EETel. 0845 30 40 705Fax. 0845 30 40 706email: [email protected] site: www.deltabloc.co.uk

H1 W6 B DELTA BLOC UK LtdUnit A Fox WayTrinity Business ParkWaldorf WayWakefield, WF2 8EETel. 0845 30 40 705Fax. 0845 30 40 706email: [email protected] site: www.deltabloc.co.uk

H1 W6 B DELTA BLOC UK LtdUnit A Fox WayTrinity Business ParkWaldorf WayWakefield, WF2 8EETel. 0845 30 40 705Fax. 0845 30 40 706email: [email protected] site: www.deltabloc.co.uk

H1 W6 B DELTA BLOC UK LtdUnit A Fox WayTrinity Business ParkWaldorf WayWakefield, WF2 8EETel. 0845 30 40 705Fax. 0845 30 40 706email: [email protected] site: www.deltabloc.co.uk

Delta Bloc DB80/4m (K120S)

Delta Bloc SB50

Delta Bloc DB65S/6m (K120S)

Delta Bloc DB80/4m (K180)

Delta Bloc DB80/6m (K150S)

Delta Bloc DB100/6m (K280)

Temporary Safety Barriers 27 January 2015

Page 31: List of EN1317 Compliant RRS January 2015

Temporary Safety Barrier Name Containment Level Working Width Class Impact Severity Level

Name and Address of Promoter Comments

H2 W5 A DELTA BLOC UK LtdUnit A Fox WayTrinity Business ParkWaldorf WayWakefield, WF2 8EETel. 0845 30 40 705Fax. 0845 30 40 706email: [email protected] site: www.deltabloc.co.uk

H2 W6 B DELTA BLOC UK LtdUnit A Fox WayTrinity Business ParkWaldorf WayWakefield, WF2 8EETel. 0845 30 40 705Fax. 0845 30 40 706email: [email protected] site: www.deltabloc.co.uk

H4a W6 B DELTA BLOC UK LtdUnit A Fox WayTrinity Business ParkWaldorf WayWakefield, WF2 8EETel. 0845 30 40 705Fax. 0845 30 40 706email: [email protected] site: www.deltabloc.co.uk

N1 W4 A Eurovia Beton12, Avenue du Juillet91412 Dourdan CedexFranceTel. (33) 01 60815200/(33) 01 64593184email: [email protected] site: www.eurovia.com

N1 W3 B Hardstaff BarriersHardstaff Traffic Barrier Services LtdHillsideGotham RoadKingston-on-SoarNottinghamNG11 0DFTel. 0115 983 2300Fax. 0115 983 0087email: [email protected] site: www.hardstaff-barriers.co.uk

Delta Bloc DB100S/6m (K220)

Delta Bloc DB80/6M (K180S)

Delta Bloc DB100/6m (K280)

Eurovia Beton 2m Transportable Concrete Barrier

Note: Only permitted for use on roads where road works are being undertaken and a speed limit of less than 50

mph is operative.

Note: Only permitted for use on roads where road works are being undertaken and a speed limit of less than 50

mph is operative.

Multibloc 80 Temporary Vertical Concrete Barrier

Temporary Safety Barriers 28 January 2015

Page 32: List of EN1317 Compliant RRS January 2015

Temporary Safety Barrier Name Containment Level Working Width Class Impact Severity Level

Name and Address of Promoter Comments

N2 W3 C Hardstaff BarriersHardstaff Traffic Barrier Services LtdHillsideGotham RoadKingston-on-SoarNottinghamNG11 0DFTel. 0115 983 2300Fax. 0115 983 0087email: [email protected] site: www.hardstaff-barriers.co.uk

N2 W3 B Hardstaff BarriersHardstaff Traffic Barrier Services LtdHillsideGotham RoadKingston-on-SoarNottinghamNG11 0DFTel. 0115 983 2300Fax. 0115 983 0087email: [email protected] site: www.hardstaff-barriers.co.uk

H4a W6 C Hardstaff BarriersHardstaff Traffic Barrier Services LtdHillsideGotham RoadKingston-on-SoarNottinghamNG11 0DFTel. 0115 983 2300Fax. 0115 983 0087email: [email protected] site: www.hardstaff-barriers.co.uk

H4a W2 C Hardstaff BarriersHardstaff Traffic Barrier Services LtdHillside

Gotham RoadKingston-on-SoarNottinghamNG11 0DFTel. 0115 983 2300Fax. 0115 983 0087email: [email protected] site: www.hardstaff-barriers.co.uk

Multibloc 110 Freestanding Temporary Vertical Concrete Barrier

The installation of temporary safety barriers with an ASI

Class of C must be with the agreement of the Overseeing

Organisation (refer to TD19/06, Sections 8.5 and

8.6).

Multibloc Freestanding Temporary Vertical Concrete Barrier

The installation of temporary safety barriers with an ASI

Class of C must be with the agreement of the Overseeing

Organisation (refer to TD19/06, Sections 8.5 and

8.6).

Maxibloc Freestanding Temporary Higher Vertical Concrete Barrier

Maxibloc Recessed Temporary Higher Vertical Concrete Barrier

The installation of temporary safety barriers with an ASI

Class of C must be with the agreement of the Overseeing

Organisation (refer to TD19/06, Sections 8.5 and

8.6).

Temporary Safety Barriers 29 January 2015

Page 33: List of EN1317 Compliant RRS January 2015

Temporary Safety Barrier Name Containment Level Working Width Class Impact Severity Level

Name and Address of Promoter Comments

N1 W8 A Highway Care Ltd.The HighlandsDetling HillDetling MaidstoneKentME14 3HTTel. 01622 734215Fax. 01622 735106email: [email protected] site: www.highwaycare.co.ukHighway Care Ltd.The HighlandsDetling HillDetling

N2 W5 A MaidstoneKent

H2 W8 A ME14 3HTTel. 01622 734215

L2 W8 A Fax. 01622 735106email: [email protected] site: www.highwaycare.co.uk

N2 W5 A Highway Care Ltd.The HighlandsDetling HillDetling MaidstoneKentME14 3HTTel. 01622 734215Fax. 01622 735106email: [email protected] site: www.highwaycare.co.uk

N2 W2 B Highway Care Ltd.The HighlandsDetling HillDetling MaidstoneKentME14 3HTTel. 01622 734215Fax. 01622 735106email: [email protected] site: www.highwaycare.co.uk

N2 W2 B Highway Care Ltd.The HighlandsDetling HillDetling MaidstoneKentME14 3HTTel. 01622 734215Fax. 01622 735106email: [email protected] site: www.highwaycare.co.uk

For a tested length of 72m between end anchors, and anchored in accordance with the EN1317 compliant test,

the working width class shall be:

Note: For a different installation length please contact the Promoter for

information concerning the Working Width of the system.

Highway Care BarrierGuard 800 - wheeled

Highway Care BarrierGuard 800 - 12m centres

Highway Care BarrierGuard 800

Armorzone Longitudinal Barrier (ALB) Note: Only permitted for use on roads where road works are being undertaken and a speed limit of less than 50

mph is operative.

Highway Care BarrierGuard 800, Minimum Deflection System (MDS)

Temporary Safety Barriers 30 January 2015

Page 34: List of EN1317 Compliant RRS January 2015

Temporary Safety Barrier Name Containment Level Working Width Class Impact Severity Level

Name and Address of Promoter Comments

N2 W4 B Highway Care Ltd.The Highlands

H2 W6 B Detling HillDetling MaidstoneKentME14 3HTTel. 01622 734215Fax. 01622 735106email: [email protected] site: www.highwaycare.co.uk

N2 W3 C NMS Civil Engineering LimitedPark Industrial EstateLiverpool RoadAshton-in MakerfieldWiganGreater ManchesterWN4 0YUTel. 01942 722694email: [email protected]

N1 W7 A Oaklands Plastics LtdStation RoadColeshillBirminghamB46 1HTTel. 01675 466321email: [email protected]

N2 W3 B REBLOC GmbHWeinerstrasse 662Gars am Kamp3571 AustriaTel. +43(2985)30922-2902Fax. +43(2985)30922-2901email: [email protected] site: www.rebloc.com

H1 W4 B REBLOC GmbHWeinerstrasse 662Gars am Kamp3571 AustriaTel. +43(2985)30922-2902Fax. +43(2985)30922-2901email: [email protected] site: www.rebloc.com

H2 W5 B REBLOC GmbHWeinerstrasse 662Gars am Kamp3571 AustriaTel. +43(2985)30922-2902Fax. +43(2985)30922-2901email: [email protected] site: www.rebloc.com

Quickchange Moveable Barrier (QMB)

NMS Civil Engineering N2TCB Freestanding Precast Concrete Barrier

The installation of temporary safety barriers with an ASI

Class of C must be with the agreement of the Overseeing

Organisation (refer to TD19/06, Sections 8.5 and

8.6).

Note: Only permitted for use on roads where road works are being undertaken and a speed limit of less than 50

mph is operative.

RB22 Water Filled Barrier

REBLOC RB80_8_H1/W4

REBLOC RB80_8_N2/W3

REBLOC RB80_8_H2/W5

Temporary Safety Barriers 31 January 2015

Page 35: List of EN1317 Compliant RRS January 2015

Temporary Safety Barrier Name Containment Level Working Width Class Impact Severity Level

Name and Address of Promoter Comments

H2 W1 B REBLOC GmbHWeinerstrasse 662Gars am Kamp3571 AustriaTel. +43(2985)30922-2902Fax. +43(2985)30922-2901email: [email protected] site: www.rebloc.com

H2 W5 B REBLOC GmbHWeinerstrasse 662Gars am Kamp3571 AustriaTel. +43(2985)30922-2902Fax. +43(2985)30922-2901email: [email protected] site: www.rebloc.com

N1 W8 A Rhino Barrier Systems Ltd.Equinox 1Audby LaneWetherbyWest YorkshireLS22 7RDTel. 01937 583333Fax. 01937 58322email: [email protected] Site: www.rhinobarriers.comSafeRoad UK Ltd.Dragonby ValeEnterprise ParkManaberg Way

H2 W8 B ScunthorpeNorth LincolnshireDN15 8XFTel. 01724 289119email: [email protected] UK Ltd.Dragonby ValeEnterprise ParkManaberg Way

N2 W6 A ScunthorpeNorth Lincolnshire

H2 W8 B DN15 8XFTel. 01724 289119email: [email protected] UK Ltd.Dragonby ValeEnterprise ParkManaberg Way

N2 W6 B ScunthorpeNorth LincolnshireDN15 8XFTel. 01724 289119email: [email protected]

For a tested length of 64m between end anchors, and anchored in accordance with the EN1317 compliant test,

the working width class shall be:

Rhino Polyethylene Water Filled Barrier System

Note: Only permitted for use on roads where road works are being undertaken and a speed limit of less than 50

mph is operative.

For a tested length of 68m between end anchors, and anchored in accordance with the EN1317 compliant test,

the working width class shall be:

Note: For a different installation length please contact the Promoter for

information concerning the Working Width of the system.

REBLOC RB80A_8_H2/W1

REBLOC RB100_2_H2/W5

Note: For a different installation length please contact the Promoter for

information concerning the Working Width of the system.

Varioguard 'Quick Joint' H2 Double Sided Steel Safety Barrier

Freestanding Varioguard with Quick Joints H2 Double Sided Steel Safety Barrier

Note: For a different installation length please contact the Promoter for

information concerning the Working Width of the system.

For a tested length of 64m between end anchors, and anchored in accordance with the EN1317 compliant test,

the working width class shall be:

Advanced Varioguard N2 Double Sided Steel Safety Barrier

Temporary Safety Barriers 32 January 2015

Page 36: List of EN1317 Compliant RRS January 2015

Temporary Safety Barrier Name Containment Level Working Width Class Impact Severity Level

Name and Address of Promoter Comments

N2 W6 A Trinity Highway Products InternationalCrown House

H2 W8 A Crown StreetIpswichSuffolkIP1 3HSTel. 01473 22 11 05Fax: 01473 22 11 06email: [email protected] site: www.energyabsorption.com

END OF TEMPORARY SAFETY BARRIER SECTION - RETURN TO CONTENTS

Vulcan Safety Barrier

Temporary Safety Barriers 33 January 2015

Page 37: List of EN1317 Compliant RRS January 2015

PARAPETS

Parapet Name Containment Level Working Width Class Dynamic Deflection (m) Are DD and WW normalised?

Vehicle Intrusion Class Impact Severity Level

Name and Address of Promoter Version of EN1317-5 to which the system was CE marked

Comments CE Marked

H2 W4 1 Yes NR A Manufacturer: Marcegaglia Srl EN1317-5:2007+A1:2008 YESDistributed by: Ferrostrada (UK) LimitedVenlaw HouseBurston RoadHeywoodSouth NorfolkIP22 5SXWeb site: www.ferrostrada-uk.comTel: 01379 308 051Fax: 01379 308 053Email: [email protected]: Jason Ferro

H2 W4 0.7 No NR B Pass and Co Barrier Systems GMBH EN1317-5:2007+A1:2008 YESDortmunderstrasse 857234 WilnsdorfGermanyTel: +49 (0)2739 4796-0Fax: +49 (0)2739 4796-110email: [email protected]

N2 NR No NA B SafeRoad UK Ltd. EN1317-5:2007+A1:2008 YES

Dragonby Vale

W1 Enterprise Park

Manaberg Way

H2 NR No NR B Scunthorpe EN1317-5:2007+A1:2008 YES

North Lincolnshire

W1 DN15 8XF

Tel. 01724 289119

H1 email: [email protected]

H2 W2 0.5 No NR B SafeRoad UK Ltd. EN1317-5:2007+A1:2008 YES

Dragonby Vale

Enterprise Park

Manaberg Way

Scunthorpe

North Lincolnshire

DN15 8XF

Tel. 01724 289119

email: [email protected]

N1 NR No NA A SafeRoad UK Ltd. EN1317-5:2007+A1:2008 YES

Dragonby ValeW2 Enterprise Park

Manaberg WayScunthorpeNorth LincolnshireDN15 8XFTel. 01724 289119email: [email protected]

N2 NR No NA B SafeRoad UK Ltd. EN1317-5:2007+A1:2008 YES

Dragonby Vale

W3 Enterprise ParkManaberg WayScunthorpeNorth LincolnshireDN15 8XFTel. 01724 289119email: [email protected]

The following Parapets have been successfully tested to meet the requirements of BS EN 1317 -1 and -2 and the HA has been advised that they have been CE marked in accordance with the Construction Products Regulation (CPR) for the Containment Performance Class and Working Width Class stated below.

Essential characteristic information only is provided and confirmation is required that the system selected complies fully with all HA contractual conditions and requirements as detailed in the DMRB, MCHW, and any contract specific or site specific documentation.

The parapets shall comply with the manufacturer's Specification, component descriptions and Installation procedures. Further information on Impact Severity Levels for the product and copies of documents and drawings can be obtained from the Promoter.

NA: Not ApplicableNR: Not Reported

Note: Only permitted for use on roads where a speed limit of

less than 50 mph is operative.

H2BP-MARC2011 bridge parapet

Super Rail BW

MegaGuard H2 Steel parapet (1.25m high)

Orsta Bridge Parapet

Phoenix N1 Aluminium Parapet

Phoenix N2 Aluminium Parapet

With post centres at 2.0m the Working Width Class is:

With post centres at 3.8m the Working Width Class is:

With post centres at 3.0m the Working Width Class is:

With post centres at 2.0m the Working Width Class is:

Parapets 34 January 2015

Page 38: List of EN1317 Compliant RRS January 2015

Parapet Name Containment Level Working Width Class Dynamic Deflection (m) Are DD and WW normalised?

Vehicle Intrusion Class Impact Severity Level

Name and Address of Promoter Version of EN1317-5 to which the system was CE marked

Comments CE Marked

N2 NR No NA B SafeRoad UK Ltd. EN1317-5:2007+A1:2008 YESDragonby Vale

W4 Enterprise ParkManaberg WayScunthorpeNorth LincolnshireDN15 8XFTel. 01724 289119email: [email protected]

H2 W2 0.4 No NR B SafeRoad UK Ltd. EN1317-5:2007+A1:2008 YESDragonby ValeEnterprise ParkManaberg WayScunthorpeNorth LincolnshireDN15 8XFTel. 01724 289119email: [email protected]

N1 NA A Tata Steel Tubes Europe YESPO Box 101

W1 Weldon RoadCorby

N1 NA A Northants YESNN17 5UA

W2 Tel. 01536 402121email:[email protected]

N2 NA B Tata Steel Tubes Europe YESPO Box 101

W3 Weldon RoadCorby

N2 NA B Northants YESNN17 5UA

W4 Tel. 01536 402121email:[email protected]

L4a/H4a VI4 B Tata Steel Tubes Europe YESPO Box 101

W4 Weldon RoadCorbyNorthantsNN17 5UATel. 01536 402121email:[email protected]

H4a Yes VI6 C Tata Steel Tubes Europe YESPO Box 101

W4 Weldon RoadCorby

H4a Yes VI6 B Northants YESNN17 5UA

W4 Tel. 01536 402121email:[email protected]

N1 NA A Tata Steel Tubes Europe YESPO Box 101

W1 Weldon RoadCorbyNorthantsNN17 5UATel. 01536 402121email:[email protected]

H2 W5 1.3 No NR B Manufacturer : EN1317-5:2007+A1:2008 YESTERTULes bois de Tertu61160 VILLEDIEU LES BAILLEUL FRANCETel : +33 2 33 36 11 02Fax : +33 2 33 39 28 75email: [email protected] by: Ferrostrada (UK) LimitedVenlaw HouseBurston RoadHeywoodSouth NorfolkIP22 5SXWeb site: www.ferrostrada-uk.comTel: 01379 308 051Fax: 01379 308 053Email: [email protected]: Jason Ferro

Note: Only permitted for use on roads where a speed limit of

less than 50 mph is operative.

Note: Only permitted for use on roads where a speed limit of

less than 50 mph is operative.

Note: For intermediate post positions the

manufacturer/Promoter will be responsible for declaring the

working width.

Protect 365 N2 parapet(formerlyCorus HBP 300 N2 Steel Parapet)

Protect 365 Clad L4a/H4a Parapet(formerly Corus Tubes Celsius HBP 300 H4a Steel Parapet)

Protect 365 Unclad H4a Parapet

The installation of parapets with an ASI Class of C must be with

the agreement of the Overseeing Organisation (refer to TD19/06,

Sections 4.11 and 4.12).With post centres between 3.5m and 4.375m the Working Width Class is:

Protect 365 N1 Parapet

(formerly Corus Protect 365 N1 3 Rail Steel Parapet)

Protect 365 N1 Vertical Infill Steel Parapet

T40 4MS2 Bridge Parapet

With post centres between 2.5m and 3.49m the Working Width Class is:

With post centres at 2.5m to 3.75m the Working Width Class is:

SN2 steel parapet

Sicuro Arc Bridge Parapet

With post centres at 3.75m the Working Width Class is:

With post centres at 2.5 to 2.99m the Working Width Class is:

With post centres at 3.0 to 3.75m the Working Width Class is:

With post centres at 2.5 to 3.75m the Working Width Class is:

With post centres at 2.5 to 3.49m the Working Width Class is:

With post centres at 2.5 to 3.75 m the Working Width Class is:

Parapets 35 January 2015

Page 39: List of EN1317 Compliant RRS January 2015

Parapet Name Containment Level Working Width Class Dynamic Deflection (m) Are DD and WW normalised?

Vehicle Intrusion Class Impact Severity Level

Name and Address of Promoter Version of EN1317-5 to which the system was CE marked

Comments CE Marked

N1 W2 NR Yes NA A Varley and Gulliver Ltd EN1317-5:2007+A1:2008 YESAlfred StreetSparkbrookBirminghamB12 8JRTel. (0121) 773 2441email: [email protected]

N2 No NA B Varley and Gulliver Ltd EN1317-5:2007+A1:2008 YESAlfred Street

W2 SparkbrookBirminghamB12 8JRTel. (0121) 773 2441email: [email protected]

N2 No NA B Varley and Gulliver Ltd EN1317-5:2007+A1:2008 YESAlfred Street

W1 SparkbrookBirminghamB12 8JRTel. (0121) 773 2441email: [email protected]

N2 NR No NA C Varley and Gulliver Ltd EN1317-5:2007+A1:2008 YESAlfred Street

W2 SparkbrookBirminghamB12 8JRTel. (0121) 773 2441email: [email protected]

N1 NR No NA A Varley and Gulliver Ltd EN1317-5:2007+A1:2008 YESAlfred Street

W1 SparkbrookBirminghamB12 8JRTel. (0121) 773 2441email: [email protected]

N1 NR No NA A Varley and Gulliver Ltd EN1317-5:2007+A1:2008 YESAlfred Street

W2 SparkbrookBirminghamB12 8JRTel. (0121) 773 2441email: [email protected]

H2 NR No NR B Varley and Gulliver Ltd EN1317-5:2007+A1:2008 YESAlfred Street

W1 SparkbrookBirminghamB12 8JRTel. (0121) 773 2441email: [email protected]

H2 NR No NR B Varley and Gulliver Ltd EN1317-5:2007+A1:2008 YESAlfred Street

W3 SparkbrookBirminghamB12 8JRTel. (0121) 773 2441email: [email protected]

H4a NR No NR B Varley and Gulliver Ltd EN1317-5:2007+A1:2008 YESAlfred Street

W4 SparkbrookBirminghamB12 8JRTel. (0121) 773 2441email: [email protected]

H4a NR No NR B Varley and Gulliver Ltd EN1317-5:2007+A1:2008 YESAlfred Street

W3 SparkbrookBirminghamB12 8JRTel. (0121) 773 2441email: [email protected]

Note: Only permitted for use on roads where a speed limit of

less than 50 mph is operative.

Note: Only permitted for use on roads where a speed limit of

less than 50 mph is operative.

VGSH 2000 H2 Steel Parapet

VGSH 4000 Steel Parapet

V6Guard H4a Steel Parapet

VGSN 500 N1 Steel Parapet

VGAN 500 N1 Aluminium Parapet

VarleyGuard Steel Parapet

With post centres at 3.6 to 4.5m, Working Width Class is:

VGAN 800 N1 Aluminium Parapet

The installation of parapets with an ASI Class of C must be with

the agreement of the Overseeing Organisation (refer to TD19/06,

Sections 4.11 and 4.12).

VGAN 1000 N2 Aluminium Parapet

VGSN 1000 N2 Steel Parapet

VGSN 900 N2 Steel Parapet

With post centres at 1.5m the Working Width Class is:

With post centres at 3.0 to 3.75m, Working Width Class is:

With post centres at 2.93 to 3.66m, Working Width Class is:

With post centres at 2.93 to 3.66m, Working Width Class is:

With post centres at 1.8 to 2.0m, Working Width Class is:

With post centres at 2.7 to 3.0m, Working Width Class is:

With post centres at 3.6 to 4.0m, Working Width Class is:

With post centres at 2.0m, Working Width Class is:

Parapets 36 January 2015

Page 40: List of EN1317 Compliant RRS January 2015

Parapet Name Containment Level Working Width Class Dynamic Deflection (m) Are DD and WW normalised?

Vehicle Intrusion Class Impact Severity Level

Name and Address of Promoter Version of EN1317-5 to which the system was CE marked

Comments CE Marked

H2 W1 0.4 Yes VI2 B VeRSco Ltd EN1317-5:2007+A1:2008 YESUnit 5Lock LaneThorneSouth YorkshireDN8 5ETTel. 07907 268 376email: [email protected]

END OF PARAPET SECTION - RETURN TO CONTENTS

Note: Although this is called the VC/H2W1 parapet, it has a VI

class of V12.

VC/H2W1

Parapets 37 January 2015

Page 41: List of EN1317 Compliant RRS January 2015

CRASH CUSHIONS

Crash Cushion Name Performance Level Redirection Zone and Lateral Displacement Classes

Impact Severity Level

Name and Address of Promoter Version of EN1317-5 to which the system was CE marked

Comments

100km/h Re - Direction Zone Class - Z4 B Asset International (A Division of Hill and Smith) EN1317-5:2007+A1:2008Springvale Avenue

Lateral Displacement Zone Class - D2 BilstonWolverhamptonWV14 0QLTel. 01902 499402Fax. 01902 402104email: [email protected] Site: www.asset-vrs.co.uk

110km/h Re - Direction Zone Class - Z3 B Asset International (A Division of Hill and Smith) EN1317-5:2007+A1:2008Springvale Avenue

Lateral Displacement Zone Class - D1 BilstonWolverhamptonWV14 0QLTel. 01902 499402Fax. 01902 402104email: [email protected] Site: www.asset-vrs.co.uk

110km/h Re - Direction Zone Class - Z3 B Asset International (A Division of Hill and Smith) EN1317-5:2007+A1:2008Springvale Avenue

Lateral Displacement Zone Class - D1 BilstonWolverhamptonWV14 0QLTel. 01902 499402Fax. 01902 402104email: [email protected] Site: www.asset-vrs.co.uk

100km/h Re - Direction Zone Class - Z4 B Asset International (A Division of Hill and Smith) EN1317-5:2007+A1:2008Springvale Avenue

Lateral Displacement Zone Class - D2 BilstonWolverhamptonWV14 0QLTel. 01902 499402Fax. 01902 402104email: [email protected] Site: www.asset-vrs.co.uk

100km/h Re - Direction Zone Class - Z4 B Asset International (A Division of Hill and Smith) Not applicable - temporary use onlySpringvale Avenue

Lateral Displacement Zone Class - D2 BilstonWolverhamptonWV14 0QLTel. 01902 499402Fax. 01902 402104email: [email protected] Site: www.asset-vrs.co.uk

110 km/h Redirection zone class - Z1 A Asset International (a division of Hill & Smith) EN1317-5:2007Lateral displacement zone class - D1 Springvale Avenue

Bilston, WolverhamptonWV14 0QL

80 km/h Redirection zone class - Z1 A Tel: 01902 499402Lateral displacement zone class - D1 Fax: 01902 402104

email: [email protected] Site: www.asset-vrs.co.uk

For use on roads with a speed limit of 50mph or less

For use on roads with a speed limit greater than 50mph

For use on roads with a speed limit greater than 50mph

For use on roads with a speed limit of 50mph or less

For use on roads with a speed limit greater than 50mph

The following Crash Cushions have been successfully tested to meet the requirements of BS EN 1317 - 3 and the HA has been advised that they have been CE marked in accordance with the Construction Products Regulation (CPR) for the Performance Level and Zone Classes stated below.

Essential characteristic information only is provided and confirmation is required that the system selected complies fully with all HA contractual conditions and requirements as detailed in the DMRB, MCHW, and any contract specific or site specific documentation.

The Crash Cushions shall comply with the manufacturer's Specification, component descriptions and Installation procedures. Copies of documents and drawings can be obtained from the Promoter.

Vecu-Stop Re-Directional and Bi-Directional Crash Cushion - Model P120/2:13 and V120/4:13

Vecu-Stop Re-Directional and Bi-Directional Crash Cushion - Model P120/2:14 and V120/4:14

Vecu-Stop Re-Directional and Bi-Directional Crash Cushion - Model P100/2:14 and V100/4:14

Vecu-Stop Re-Directional and Bi-Directional Crash Cushion - Model P100/2:13 and V100/4:13

EuroTRACC 110 re-directional and bi-directional crash cushion

EuroTRACC 80 re-directional and bi-directional crash cushion

Vecu-Stop Temporary Crash Cushion

For use on roads with a speed limit of 50mph or less

Crash Cushions 38 January 2015

Page 42: List of EN1317 Compliant RRS January 2015

Crash Cushion Name Performance Level Redirection Zone and Lateral Displacement Classes

Impact Severity Level

Name and Address of Promoter Version of EN1317-5 to which the system was CE marked

Comments

110 km/h Redirection zone class - Z1 B Asset International (a division of Hill & Smith) EN1317-5:2007Lateral displacement zone class - D1 Springvale Avenue

Bilston, WolverhamptonWV14 0QL

80 km/h Redirection zone class - Z1 B Tel: 01902 499402Lateral displacement zone class - D1 Fax: 01902 402104

email: [email protected] Site: www.asset-vrs.co.uk

110 km/h Redirection zone class - Z1 B Asset International (a division of Hill & Smith) EN1317-5:2007+A1:2008Lateral displacement zone class - D1 Springvale Avenue

100 km/h Redirection zone class - Z1 B Bilston, WolverhamptonLateral displacement zone class - D1 WV14 0QL

80 km/h Redirection zone class - Z1 B Tel: 01902 499402Lateral displacement zone class - D1 Fax: 01902 402104

50 km/h Redirection zone class - Z1 B email: [email protected] displacement zone class - D1 Web Site: www.asset-vrs.co.uk

110 km/h Redirection zone class - Z2 B Asset International (a division of Hill & Smith) EN1317-5:2007Lateral displacement zone class - D2 Springvale Avenue

100 km/h Redirection zone class - Z2 B Bilston, WolverhamptonLateral displacement zone class - D2 WV14 0QL

80 km/h Redirection zone class - Z1 A Tel: 01902 499402Lateral displacement zone class - D1 Fax: 01902 402104

email: [email protected] Site: www.asset-vrs.co.uk

110km/h Re - Direction Zone Class - Z1 B Highway Care Ltd.Lateral Displacement Zone Class - D1 The Highlands

100km/h Re - Direction Zone Class - Z1 B Detling HillLateral Displacement Zone Class - D1 Detling

80km/h Re - Direction Zone Class - Z1 B MaidstoneLateral Displacement Zone Class - D1 Kent

50km/h Re - Direction Zone Class - Z1 B ME14 3HTLateral Displacement Zone Class - D1 Tel. 01622 734215

Fax. 01622 735106email: [email protected] site: www.highwaycare.co.uk

110km/h Re - Direction Zone Class - Z1 B Highway Care Ltd.Lateral Displacement Zone Class - D1 The Highlands

100km/h Re - Direction Zone Class - Z1 B Detling HillLateral Displacement Zone Class - D1 Detling

80km/h Re - Direction Zone Class - Z1 B MaidstoneLateral Displacement Zone Class - D1 Kent

50km/h Re - Direction Zone Class - Z1 B ME14 3HTLateral Displacement Zone Class - D1 Tel. 01622 734215

Fax. 01622 735106email: [email protected] site: www.highwaycare.co.uk

110km/h Re - Direction Zone Class - Z1 B Highway Care Ltd.Lateral Displacement Zone Class - D1 The Highlands

100km/h Re - Direction Zone Class - Z1 B Detling HillLateral Displacement Zone Class - D1 Detling

80km/h Re - Direction Zone Class - Z1 B MaidstoneLateral Displacement Zone Class - D1 Kent

50km/h Re - Direction Zone Class - Z1 B ME14 3HTLateral Displacement Zone Class - D1 Tel. 01622 734215

Fax. 01622 735106email: [email protected] site: www.highwaycare.co.uk

For use on roads with a speed limit of 50mph or less

For use on roads with a speed limit greater than 50mph

For use on roads with a speed limit greater than 50mph

For use on roads with a speed limit of 50mph or less

For use on roads with a speed limit greater than 50mph

EuroTRACC 80 Wide re-directional and bi-directional crash cushion

QuadGuard™ CEN re-directional and bi-directional crash cushion

Quest™ CEN re-directional and bi-directional crash cushion

TAU Bi-Directional and Re-Directional Parallel Crash Cushions

TAU Bi-Directional and Re-Directional Medium Crash Cushions

TAU Bi-Directional and Re-Directional Large Crash Cushions

For use on roads with a speed limit greater than 50mph

For use on roads with a speed limit of 50mph or less

EuroTRACC 110 Wide re-directional and bi-directional crash cushion

For use on roads with a speed limit greater than 50mph

For use on roads with a speed limit of 50mph or less

For use on roads with a speed limit greater than 50mph

For use on roads with a speed limit of 50mph or less

Crash Cushions 39 January 2015

Page 43: List of EN1317 Compliant RRS January 2015

Crash Cushion Name Performance Level Redirection Zone and Lateral Displacement Classes

Impact Severity Level

Name and Address of Promoter Version of EN1317-5 to which the system was CE marked

Comments

110km/h Re - Direction Zone Class - Z1 B Highway Care Ltd.Lateral Displacement Zone Class - D1 The Highlands

100km/h Re - Direction Zone Class - Z1 B Detling HillLateral Displacement Zone Class - D1 Detling

80km/h Re - Direction Zone Class - Z1 B MaidstoneLateral Displacement Zone Class - D1 Kent

50km/h Re - Direction Zone Class - Z1 B ME14 3HTLateral Displacement Zone Class - D1 Tel. 01622 734215

Fax. 01622 735106email: [email protected] site: www.highwaycare.co.uk

110km/h Re - Direction Zone Class - Z2 B Highway Care Ltd.Lateral Displacement Zone Class - D1 The Highlands

Detling HillDetling MaidstoneKentME14 3HTTel. 01622 734215Fax. 01622 735106email: [email protected] site: www.highwaycare.co.uk

110km/h Re - Direction Zone Class - Z1 B Industry AMS SrlLateral Displacement Zone Class - D4 Via Eduardo De Filippo, 11

100km/h Re - Direction Zone Class - Z1 B 80013 CasalnuovoLateral Displacement Zone Class - D4 Italy

80km/h Re - Direction Zone Class - Z1 B Tel: 0823 821560Lateral Displacement Zone Class - D4 Fax: 0823 821067

50km/h Re - Direction Zone Class - Z1 B email: [email protected] Displacement Zone Class - D4 web site: www.smaroadsafety.com

110km/h Re - Direction Zone Class - Z1 B Industry AMS SrlLateral Displacement Zone Class - D4 Via Eduardo De Filippo, 11

100km/h Re - Direction Zone Class - Z1 B 80013 CasalnuovoLateral Displacement Zone Class - D4 Italy

80km/h Re - Direction Zone Class - Z1 B Tel: 0823 821560Lateral Displacement Zone Class - D4 Fax: 0823 821067

email: [email protected] site: www.smaroadsafety.com

110km/h Re - Direction Zone Class - Z1 B Industry AMS SrlLateral Displacement Zone Class - D4 Via Eduardo De Filippo, 11

100km/h Re - Direction Zone Class - Z1 B 80013 CasalnuovoLateral Displacement Zone Class - D4 Italy

80km/h Re - Direction Zone Class - Z1 B Tel: 0823 821560Lateral Displacement Zone Class - D4 Fax: 0823 821067

50km/h Re - Direction Zone Class - Z1 B email: [email protected] Displacement Zone Class - D4 web site: www.smaroadsafety.com

110km/h Re - Direction Zone Class - Z1 B Industry AMS SrlLateral Displacement Zone Class - D4 Via Eduardo De Filippo, 11

100km/h Re - Direction Zone Class - Z1 B 80013 CasalnuovoLateral Displacement Zone Class - D4 Italy

80km/h Re - Direction Zone Class - Z1 B Tel: 0823 821560Lateral Displacement Zone Class - D4 Fax: 0823 821067

email: [email protected] site: www.smaroadsafety.com

110km/h Re - Direction Zone Class - Z1 B Industry AMS SrlLateral Displacement Zone Class - D4 Via Eduardo De Filippo, 11

100km/h Re - Direction Zone Class - Z1 B 80013 CasalnuovoLateral Displacement Zone Class - D4 Italy

80km/h Re - Direction Zone Class - Z1 B Tel: 0823 821560Lateral Displacement Zone Class - D4 Fax: 0823 821067

email: [email protected] site: www.smaroadsafety.com

TAU Bi-Directional and Re-Directional X-Large Crash Cushions

For use on roads with a speed limit greater than 50mph

For use on roads with a speed limit of 50mph or less

For use on roads with a speed limit of 50mph or less

SMA SEMI-WIDE Crash Cushions

For use on roads with a speed limit greater than 50mph

TAU Tube P110 Crash Cushion

SMA Crash Cushions For use on roads with a speed limit greater than 50mph

For use on roads with a speed limit of 50mph or less

For use on roads with a speed limit greater than 50mph

For use on roads with a speed limit of 50mph or less

SMA WL Crash Cushions For use on roads with a speed limit greater than 50mph

For use on roads with a speed limit of 50mph or less

For use on roads with a speed limit greater than 50mph

SMA SLIM Crash Cushions

For use on roads with a speed limit of 50mph or less

SMA WIDE Crash Cushions For use on roads with a speed limit greater than 50mph

Crash Cushions 40 January 2015

Page 44: List of EN1317 Compliant RRS January 2015

Crash Cushion Name Performance Level Redirection Zone and Lateral Displacement Classes

Impact Severity Level

Name and Address of Promoter Version of EN1317-5 to which the system was CE marked

Comments

110km/h Re - Direction Zone Class - Z4 B Shindo Industry Co Ltd EN1317-5:2007+A1:2008Lateral Displacement Zone Class - D6 922-3 Dongpae-Ri

Gyoha-eup100km/h Re - Direction Zone Class - Z2 B Paju-city

Lateral Displacement Zone Class - D1 Gyeonggi-Do413-834

80km/h Re - Direction Zone Class - Z1 B KoreaLateral Displacement Zone Class - D1 Tel: 82-31-9438008

Fax: 82-31-949001350km/h Re - Direction Zone Class - Z1 B Email: [email protected]

Lateral Displacement Zone Class - D1110km/h Re - Direction Zone Class - Z2 A Shindo Industry Co Ltd EN1317-5:2007+A1:2008

Lateral Displacement Zone Class - D1 922-3 Dongpae-RiGyoha-eup

100km/h Re - Direction Zone Class - Z2 A Paju-cityLateral Displacement Zone Class - D1 Gyeonggi-Do

413-83480km/h Re - Direction Zone Class - Z1 A Korea

Lateral Displacement Zone Class - D1 Tel: 82-31-9438008Fax: 82-31-9490013

50km/h Re - Direction Zone Class - Z1 A Email: [email protected] Displacement Zone Class - D1

110 km/h Redirection zone class - Z1 A Trinity Highway Products International EN1317-5:2007Lateral displacement zone class - D1 Crown House, Crown Street

IpswichIP1 3HS

80 km/h Redirection zone class - Z1 A Tel: 01473 221105Lateral displacement zone class - D1 Fax: 01473 221106

Email: [email protected]: www.highwayguardrail.com

110 km/h Redirection zone class - Z1 B Trinity Highway Products International EN1317-5:2007Lateral displacement zone class - D1 Crown House, Crown Street

IpswichIP1 3HS

80 km/h Redirection zone class - Z1 B Tel: 01473 221105Lateral displacement zone class - D1 Fax: 01473 221106

Email: [email protected]: www.highwayguardrail.com

110 km/h Redirection zone class - Z1 B Trinity Highway Products International EN1317-5:2007+A1:2008Lateral displacement zone class - D1 Crown House, Crown Street

100 km/h Redirection zone class - Z1 B IpswichLateral displacement zone class - D1 IP1 3HS

80 km/h Redirection zone class - Z1 B Tel: 01473 221105Lateral displacement zone class - D1 Fax: 01473 221106

50 km/h Redirection zone class - Z1 B Email: [email protected] displacement zone class - D1 Website: www.energyabsorption.com

110 km/h Redirection zone class - Z2 B Trinity Highway Products International EN1317-5:2007Lateral displacement zone class - D2 Crown House, Crown Street

100 km/h Redirection zone class - Z2 B IpswichLateral displacement zone class - D2 IP1 3HS

80 km/h Redirection zone class - Z1 A Tel: 01473 221105Lateral displacement zone class - D1 Fax: 01473 221106

Email: [email protected]: www.energyabsorption.com

100 km/h Redirection zone class - Z1 A Trinity Highway Products International EN1317-5:2007Crown House, Crown StreetIpswichIP1 3HSTel: 01473 221105Fax: 01473 221106Email: [email protected]: www.energyabsorption.com

END OF CRASH CUSHION SECTION - RETURN TO CONTENTS

For use on roads with a speed limit greater than 50mph

For use on roads with a speed limit of 50mph or less

EuroTRACC 110 re-directional and bi-directional crash cushion

EuroTRACC 80 re-directional and bi-directional crash cushion

EuroTRACC 110 Wide re-directional and bi-directional crash cushion

EuroTRACC 80 Wide re-directional and bi-directional crash cushion

QuadGuard™ CEN re-directional and bi-directional crash cushion

Quest™ CEN re-directional and bi-directional crash cushion

EU CCS II

For use on roads with a speed limit of 50mph or less

For use on roads with a speed limit greater than 50mph

For use on roads with a speed limit of 50mph or less

For use on roads with a speed limit greater than 50mph

For use on roads with a speed limit greater than 50mph

For use on roads with a speed limit greater than 50mph

For use on roads with a speed limit of 50mph or less

For use on roads with a speed limit greater than 50mph

For use on roads with a speed limit of 50mph or less

Fitch Universal Module System

Cushion Tank System

Crash Cushions 41 January 2015

Page 45: List of EN1317 Compliant RRS January 2015

TERMINALS

Terminal Name Performance Class PLDZ Class Exit Box Class/Vehicle Redirection Zone

Impact Severity Level

Name and Address of Promoter Comments

P4 D2.4 Z2 B Acklea Ltd/Traffix DevicesUnit 1Clark AvenuePorte Marsh Industrial EstateClaneWiltshireSN11 9RDTel. 01249 822 600Fax. 01249 820 111email: [email protected]

P4 D2.4 Z2 B Acklea Ltd/Traffix DevicesUnit 1Clark AvenuePorte Marsh Industrial EstateClaneWiltshire

SN11 9RDTel. 01249 822 600Fax. 01249 820 111email: [email protected]

P4 D.1.1 Z1 A Brifen (A Division of Hill and Smith)Springvale Business and Industrial ParkBilstonWolverhampton

West MidlandsWV14 0QL

H1 Tel: 01902 499400Fax: 01902 499419Email: [email protected]: www.hill-smith.co.uk

50mph or more

The following Terminals for safety barriers have been successfully tested to meet the requirements of DD ENV 1317 - 4 and have been accepted for use on the Highways Agency Trunk Road Network for the Performance Class and Permanent Lateral Displacement Zone (PLDZ) Class Code stated below.

The Terminals shall comply with the manufacturer's Specification, component descriptions and Installation procedures. Essential characteristic information only is provided and confirmation is required that the system selected complies fully with all HA contractual conditions and requirements as detailed in

the DMRB, MCHW, and any contract specific or site specific documentation.Additional information on Exit Box and Impact Severity Levels for the product and copies of documents and drawings can be obtained from the Promoter.

Installers shall have successfully undertaken suitable training for the system to be installed.

Note: please refer to Table 6, DD ENV 1317 - 4 for PLDZ and Class Codes for terminals. The values of Displacement (measured in metres) Da and Dd are converted to Class Code x and y. Therefore Class Code D1.1 (where 'D' is displacement) represents 0.5m displacement (x), measured from the traffic face of the barrier towards the traffic, and 1.0m (y) measured from the

traffic face of the barrier to the rear of the barrier. D1.3 represents a displacement of 0.5m in front of the barrier and 3.5m to the rear of the barrier.

SLED Euro terminal (connected to VarioGuard)

SLED Euro terminal (connected to BarrierGuard)

Brifen P4 Wire Rope End Terminal for Brifen 4 Rope Safety Fence

50mph or more

50mph or more

Terminals 42 January 2015

Page 46: List of EN1317 Compliant RRS January 2015

Terminal Name Performance Class PLDZ Class Exit Box Class/Vehicle Redirection Zone

Impact Severity Level

Name and Address of Promoter Comments

P4 D.1.1 Z1 A Brifen (A Division of Hill and Smith)Springvale Business and Industrial ParkBilston

WolverhamptonWest MidlandsWV14 0QLTel: 01902 499400Fax: 01902 499419Email: [email protected]: www.hill-smith.co.uk

P4 D.1.1 Z2 B Highway Care Ltd.The HighlandsDetling HillDetling MaidstoneKentME14 3HTTel. 01622 734215Fax. 01622 735106email: [email protected] site: www.highwaycare.co.uk

P4 D.1.1 Z2 B Highway Care Ltd.The HighlandsDetling HillDetling MaidstoneKentME14 3HTTel. 01622 734215Fax. 01622 735106email: [email protected] site: www.highwaycare.co.uk

P4 D.1.1 Z2 B Highway Care Ltd.The HighlandsDetling HillDetling MaidstoneKentME14 3HTTel. 01622 734215Fax. 01622 735106email: [email protected] site: www.highwaycare.co.uk

Double Sided Xtension P4 Terminal connected to Double Sided Flexbeam N2W1, N2W2 or N2W3 safety barrier

Brifen P4 Wire Rope End Terminal for Brifen 3 Rope Safety Fence

Single Sided Xtension P4 Terminal (Xtension 110 Terminal)

Double Sided Xtension P4 Terminal (also known as the X-Tension 110 Double Sided P4 Terminal (XT-DS110))

50mph or more

50mph or more

50mph or more

50mph or more

Terminals 43 January 2015

Page 47: List of EN1317 Compliant RRS January 2015

Terminal Name Performance Class PLDZ Class Exit Box Class/Vehicle Redirection Zone

Impact Severity Level

Name and Address of Promoter Comments

P4 D.1.1 Z2 B Highway Care Ltd.The HighlandsDetling HillDetling MaidstoneKentME14 3HTTel. 01622 734215Fax. 01622 735106email: [email protected] site: www.highwaycare.co.uk

P4 D.1.1 Z2 B Highway Care Ltd.The HighlandsDetling HillDetling MaidstoneKentME14 3HTTel. 01622 734215Fax. 01622 735106email: [email protected] site: www.highwaycare.co.uk

P4 D.1.1 Z1 B Hill and SmithSpringvale Business and Industrial ParkBilstonWolverhamptonWest MidlandsWV14 0QLTel: 01902 499400Fax: 01902 499419Email: [email protected]: www.hill-smith.co.uk

P4 D.1.3 Z1 A Hill and SmithSpringvale Business and Industrial ParkBilstonWolverhamptonWest MidlandsWV14 0QLTel: 01902 499400Fax: 01902 499419Email: [email protected]: www.hill-smith.co.uk

Euro ET End Terminal

Double Sided Xtension P4 Terminal connected to Vetex Double Sided N2W1, N2W2 or N2W3 safety barrier

ABC Terminal

Double Sided Xtension P4 Terminal connected to Vetex Single Sided N2W1, N2W2 or N2W3 safety barrier

50mph or more, verge only

50mph or more

50mph or more

50mph or more

Terminals 44 January 2015

Page 48: List of EN1317 Compliant RRS January 2015

Terminal Name Performance Class PLDZ Class Exit Box Class/Vehicle Redirection Zone

Impact Severity Level

Name and Address of Promoter Comments

P1 D.1.1 Z1 A Hill and SmithSpringvale Business and Industrial ParkBilstonWolverhamptonWest MidlandsWV14 0QLTel: 01902 499400Fax: 01902 499419Email: [email protected]: www.hill-smith.co.uk

P1 D.1.1 Z1 A Hill and SmithSpringvale Business and Industrial ParkBilstonWolverhamptonWest MidlandsWV14 0QLTel: 01902 499400Fax: 01902 499419Email: [email protected]: www.hill-smith.co.uk

P1 D.1.1 Z1 A Hill and SmithSpringvale Business and Industrial ParkBilstonWolverhamptonWest MidlandsWV14 0QLTel: 01902 499400Fax: 01902 499419Email: [email protected]: www.hill-smith.co.uk

P4 D2.3 Z1 B Hill and SmithSpringvale Business and Industrial ParkBilstonWolverhamptonWest MidlandsWV14 0QLTel: 01902 499400Fax: 01902 499419Email: [email protected]: www.hill-smith.co.uk

P4 D.1.1 Z2 A Hill and SmithSpringvale Business and Industrial ParkBilstonWolverhamptonWest MidlandsWV14 0QLTel: 01902 499400Fax: 01902 499419Email: [email protected]: www.hill-smith.co.uk

TREND CEN End Terminal

Flex-Beam Double Sided P1 End Terminal

Flex-Beam Single Sided P1 End Terminal

Hill and Smith 'Safety Line' Wire Rope Safety Fence Terminal

Euro BXT Terminal

Less than 50mph, or on the departure end of a safety barrier not facing oncoming traffic where

the speed limit is 50mph or more.

50 mph or more

Less than 50mph, or on the departure end of a safety barrier not facing oncoming traffic where

the speed limit is 50mph or more.

50mph or more

Less than 50mph, or on the departure end of a safety barrier not facing oncoming traffic where

the speed limit is 50mph or more.

Terminals 45 January 2015

Page 49: List of EN1317 Compliant RRS January 2015

Terminal Name Performance Class PLDZ Class Exit Box Class/Vehicle Redirection Zone

Impact Severity Level

Name and Address of Promoter Comments

P4 D.1.1 Z2 B Hill and SmithSpringvale Business and Industrial ParkBilstonWolverhamptonWest MidlandsWV14 0QLTel: 01902 499400Fax: 01902 499419Email: [email protected]: www.hill-smith.co.uk

P4 D1.2 Z1 B Distributed by: Ferrostrada (UK) LimitedVenlaw HouseBurston RoadHeywoodSouth NorfolkIP22 5SXWeb site: www.ferrostrada-uk.comTel: 01379 308 051Fax: 01379 308 053Email: [email protected]: Jason Ferro

P1 D1.1 Z1 A SafeRoad UK Ltd.Dragonby ValeEnterprise ParkManaberg WayScunthorpeNorth LincolnshireDN15 8XFTel. 01724 289119email: [email protected]

P4 D1.1 Z1 B SafeRoad UK Ltd.Dragonby ValeEnterprise ParkManaberg WayScunthorpeNorth LincolnshireDN15 8XFTel. 01724 289119email: [email protected]

P4 D1.1 Z1 B SafeRoad UK Ltd.Dragonby ValeEnterprise ParkManaberg WayScunthorpeNorth LincolnshireDN15 8XFTel. 01724 289119email: [email protected]

TREND CEN DS Double Sided End Terminal

SafeEnd T110

SafeEnd P1 terminal

Sistema P4 Performance Terminal

50mph or more

Less than 50mph, or on the departure end of a safety barrier not facing oncoming traffic where

the speed limit is 50mph or more.

50mph or more

50 mph or more

SafeEnd P4 50mph or more

Terminals 46 January 2015

Page 50: List of EN1317 Compliant RRS January 2015

Terminal Name Performance Class PLDZ Class Exit Box Class/Vehicle Redirection Zone

Impact Severity Level

Name and Address of Promoter Comments

P1 D.1.1 Z1 A Tata Steel Construction ProductsLlanwern WorksNewportSouth WalesNP19 4QZTel. 01633 290011 email: [email protected]

P4 D.1.1 Z2 A Trinity Highway Products InternationalCrown House, Crown StreetIpswichIP1 3HSTel: 01473 221105Fax: 01473 221106Email: [email protected]: www.energyabsorption.com

P4 D.1.1 Z2 B Trinity Highway Products InternationalCrown House, Crown StreetIpswichIP1 3HSTel: 01473 221105Fax: 01473 221106Email: [email protected]: www.energyabsorption.com

P4 D.1.3 Z1 A Trinity Highway Products InternationalCrown House, Crown StreetIpswichIP1 3HSTel: 01473 221105Fax: 01473 221106Email: [email protected]: www.highwayguardrail.com

P4 D2.3 Z1 B Trinity Highway Products InternationalCrown House, Crown StreetIpswichIP1 3HSTel: 01473 221105Fax: 01473 221106Email: [email protected]: www.highwayguardrail.com

TREND CEN DS Double Sided End Terminal

Euro ET End Terminal

TREND CEN End Terminal

50 mph or more, verge only

50 mph or more

50 mph or more

Less than 50mph, or on the departure end of a safety barrier not facing oncoming traffic where

the speed limit is 50mph or more.

Euro BXT End Terminal

50 mph or more

Tata Steel Vetex P1 End Terminal

Terminals 47 January 2015

Page 51: List of EN1317 Compliant RRS January 2015

Terminal Name Performance Class PLDZ Class Exit Box Class/Vehicle Redirection Zone

Impact Severity Level

Name and Address of Promoter Comments

P4 D.1.1 Z1 B Trinity Highway Products InternationalCrown House, Crown StreetIpswichIP1 3HSTel: 01473 221105Fax: 01473 221106Email: [email protected]

Website: www.energyabsorption.com

END OF TERMINAL SECTION - RETURN TO CONTENTS

ABC End Terminal

Terminals detailed in the NPSBS, such as those for TCB and OBB, are deemed acceptable for use on the Highways Agency Trunk Road Network on roads with a speed limit less than 50 mph. In addition the terminals can be used on the departure end of safety barriers where the terminal does not face oncoming traffic and the speed limit is 50mph or more.

These terminals do not need a Departure from Standard submission, as they have proven in-service use over a number of years. Please contact the Promoter's of DROBB, OBB and TCB listed in the Safety Barrier section for further information.

Installers shall have successfully undertaken suitable training for the system to be installed.

50 mph or more

Terminals 48 January 2015

Page 52: List of EN1317 Compliant RRS January 2015

TRANSITIONS

Transition Name Containment Level Working Width Class Impact Severity Level Name and Address of Promoter Comments

N2 W2 B Asset International (A Division of Hill and Smith)Springvale AvenueBilstonWolverhamptonWV14 0QLTel. 01902 499402Fax. 01902 402104email: [email protected] Site: www.asset-vrs.co.uk

N2 Contact the promotor Contact the promotor Asset International (A Division of Hill and Smith)Springvale AvenueBilstonWolverhamptonWV14 0QLTel. 01902 499402Fax. 01902 402104email: [email protected] Site: www.asset-vrs.co.uk

N2 Contact the promotor Contact the promotor Asset International (A Division of Hill and Smith)Springvale AvenueBilstonWolverhamptonWV14 0QLTel. 01902 499402Fax. 01902 402104email: [email protected] Site: www.asset-vrs.co.uk

H1 Contact the promotor Contact the promotor Asset International (A Division of Hill and Smith)Springvale AvenueBilstonWolverhamptonWV14 0QLTel. 01902 499402Fax. 01902 402104email: [email protected] Site: www.asset-vrs.co.uk

The following Transitions have been successfully tested and/or independantly assessed against the requirements of ENV 1317 - 4 and have been accepted for use on the Highways Agency Trunk Road Network for the Containment Performance Class and Working Width Class stated below.

The Transition shall comply with the manufacturer's Specification, component descriptions and Installation procedures. Further information on Impact Severity Levels for the product and copies of documents and drawings can be obtained from the Promoter.

Essential characteristic information only is provided and confirmation is required that the system selected complies fully with all HA contractual conditions and requirements as detailed in the DMRB, MCHW, and any contract specific or site specific documentation.

Installers shall have successfully undertaken suitable training for the system to be installed.

Varioguard Transition (Transition between VarioGuard and safety barrier)

Open Box Beam (OBB) and Double Sided OBB (DSOBB) to Steel Step Barrier (SSB) transition

Single sided Flexbeam to Varioguard transition

Double sided Flexbeam to Varioguard transition

Transitions 49 January 2015

Page 53: List of EN1317 Compliant RRS January 2015

Transition Name Containment Level Working Width Class Impact Severity Level Name and Address of Promoter Comments

H2 Contact the promotor Contact the promotor Asset International (A Division of Hill and Smith)Springvale Avenue

BilstonWolverhamptonWV14 0QLTel. 01902 499402Fax. 01902 402104email: [email protected] Site: www.asset-vrs.co.uk

N2 W6 A Brifen (A Division of Hill and Smith)Springvale Business and Industrial ParkBilstonWolverhamptonWest MidlandsWV14 0QLTel: 01902 499400Fax: 01902 499419Email: [email protected]

Web: www.hill-smith.co.ukN2 Contact the promotor Contact the promotor Britpave Barrier Systems Ltd

Atrium CourtThe RingBracknellBerkshireRG12 1BWTel. 01344 393300email: [email protected] site: www.bbsbarriers.com

H2 Contact the promotor Contact the promotor Britpave Barrier Systems LtdAtrium Court

The RingBracknellBerkshireRG12 1BWTel. 01344 393300email: [email protected] site: www.bbsbarriers.com

H2 W2 B Britpave Barrier Systems LtdAtrium CourtThe RingBracknellBerkshireRG12 1BWTel. 01344 393300email: [email protected] site: www.bbsbarriers.com

N2 Contact promoter Contact promotor DELTA BLOC UK LtdUnit A Fox WayTrinity Business ParkWaldorf WayWakefield, WF2 8EETel. 0845 30 40 705Fax. 0845 30 40 706email: [email protected] site: www.deltabloc.co.uk

Concrete Step Barrier type 5 to Steel Step Barrier transition (including Steel Step Corridor)

BRITRANS' Open Box Beam to Wire Rope Safety Fence Transition

Britpave Concrete Step Barrier to Open Box Beam Transition

Britpave Concrete Step Barrier to Britpave Steel Step Barrier Transition

DB80AS-E to single sided OBB transition

Delta Bloc EP-REP/CJO/EOS

Transitions 50 January 2015

Page 54: List of EN1317 Compliant RRS January 2015

Transition Name Containment Level Working Width Class Impact Severity Level Name and Address of Promoter Comments

N2 Contact promoter Contact promotor DELTA BLOC UK LtdUnit A Fox WayTrinity Business ParkWaldorf WayWakefield, WF2 8EETel. 0845 30 40 705Fax. 0845 30 40 706email: [email protected] site: www.deltabloc.co.uk

N2 Contact promoter Contact promotor DELTA BLOC UK LtdUnit A Fox WayTrinity Business ParkWaldorf WayWakefield, WF2 8EETel. 0845 30 40 705Fax. 0845 30 40 706email: [email protected] site: www.deltabloc.co.uk

N2 Contact promoter Contact promotor DELTA BLOC UK LtdUnit A Fox WayTrinity Business ParkWaldorf WayWakefield, WF2 8EETel. 0845 30 40 705Fax. 0845 30 40 706email: [email protected] site: www.deltabloc.co.uk

H2 W4 C DELTA BLOC UK LtdUnit A Fox WayTrinity Business ParkWaldorf WayWakefield, WF2 8EETel. 0845 30 40 705Fax. 0845 30 40 706email: [email protected] site: www.deltabloc.co.uk

H2 W4 C DELTA BLOC UK LtdUnit A Fox WayTrinity Business ParkWaldorf WayWakefield, WF2 8EETel. 0845 30 40 705Fax. 0845 30 40 706email: [email protected] site: www.deltabloc.co.uk

H2 W4 C DELTA BLOC UK LtdUnit A Fox WayTrinity Business ParkWaldorf WayWakefield, WF2 8EETel. 0845 30 40 705Fax. 0845 30 40 706email: [email protected] site: www.deltabloc.co.uk

DB80 6m to single sided OBB transition

DB80E to double sided OBB transition

DB80 6m to double sided OBB

DELTA BLOC In Situ 90 Step to DB80E 6m K150 transition

DELTA BLOC In Situ 90 Step to DB80 6m K180 transition

DELTA BLOC In Situ 90 Step to DB90 Step 6m K220 transition

Use of this transition must be with the agreement of the Overseeing Organisation

(refer to TD19/06, Section 6.6).

Use of this transition must be with the agreement of the Overseeing Organisation

(refer to TD19/06, Section 6.6).

Use of this transition must be with the agreement of the Overseeing Organisation

(refer to TD19/06, Section 6.6).

Transitions 51 January 2015

Page 55: List of EN1317 Compliant RRS January 2015

Transition Name Containment Level Working Width Class Impact Severity Level Name and Address of Promoter Comments

H2 W4 C DELTA BLOC UK LtdUnit A Fox WayTrinity Business ParkWaldorf WayWakefield, WF2 8EETel. 0845 30 40 705Fax. 0845 30 40 706email: [email protected] site: www.deltabloc.co.uk

H2 W1 C DELTA BLOC UK LtdUnit A Fox WayTrinity Business ParkWaldorf WayWakefield, WF2 8EETel. 0845 30 40 705Fax. 0845 30 40 706email: [email protected] site: www.deltabloc.co.uk

H2 W1 B DELTA BLOC UK LtdUnit A Fox WayTrinity Business ParkWaldorf WayWakefield, WF2 8EETel. 0845 30 40 705Fax. 0845 30 40 706email: [email protected] site: www.deltabloc.co.uk

H2 Contact the promotor Contact the promotor DELTA BLOC UK LtdUnit A Fox WayTrinity Business ParkWaldorf WayWakefield, WF2 8EETel. 0845 30 40 705Fax. 0845 30 40 706email: [email protected] site: www.deltabloc.co.uk

H2 Contact the promotor Contact the promotor DELTA BLOC UK LtdUnit A Fox WayTrinity Business ParkWaldorf WayWakefield, WF2 8EETel. 0845 30 40 705Fax. 0845 30 40 706email: [email protected] site: www.deltabloc.co.uk

DB SafeLink Transition (DB100S to DB90 Step)

DELTA BLOC Single row DB90 Step 6m K220 to double row DB80 AS-E 6m K180S (bifurcation)

DELTA BLOC Single row DB80E 6m K150S to double row DB80 AS-E 6m K180S (bifurcation)

EP80B-E to DB 80AS-E

EP80B-E to CSB profile

Use of this transition must be with the agreement of the Overseeing Organisation

(refer to TD19/06, Section 6.6).

Use of this transition must be with the agreement of the Overseeing Organisation

(refer to TD19/06, Section 6.6).

Transitions 52 January 2015

Page 56: List of EN1317 Compliant RRS January 2015

Transition Name Containment Level Working Width Class Impact Severity Level Name and Address of Promoter Comments

H2 Contact the promotor Contact the promotor DELTA BLOC UK LtdUnit A Fox WayTrinity Business ParkWaldorf WayWakefield, WF2 8EETel. 0845 30 40 705Fax. 0845 30 40 706email: [email protected] site: www.deltabloc.co.uk

H2 Contact the promotor Contact the promotor DELTA BLOC UK LtdUnit A Fox WayTrinity Business ParkWaldorf WayWakefield, WF2 8EETel. 0845 30 40 705Fax. 0845 30 40 706email: [email protected] site: www.deltabloc.co.uk

H2 Contact the promotor Contact the promotor DELTA BLOC UK LtdUnit A Fox WayTrinity Business ParkWaldorf WayWakefield, WF2 8EETel. 0845 30 40 705Fax. 0845 30 40 706email: [email protected] site: www.deltabloc.co.uk

H2 Contact the promotor Contact the promotor DELTA BLOC UK LtdUnit A Fox WayTrinity Business ParkWaldorf WayWakefield, WF2 8EETel. 0845 30 40 705Fax. 0845 30 40 706email: [email protected] site: www.deltabloc.co.uk

H2 Contact the promotor Contact the promotor DELTA BLOC UK LtdUnit A Fox WayTrinity Business ParkWaldorf WayWakefield, WF2 8EETel. 0845 30 40 705Fax. 0845 30 40 706email: [email protected] site: www.deltabloc.co.uk

EP80B-E to rigid structures

Single row EP80B-E to double row DB80AS-E (bifurcation)

Single row EP80B-E to double row EP80B-E (bifurcation)

DB100S to EP80Ba transition

DB80-E to EP80Ba transition

Transitions 53 January 2015

Page 57: List of EN1317 Compliant RRS January 2015

Transition Name Containment Level Working Width Class Impact Severity Level Name and Address of Promoter Comments

H2 Contact the promotor Contact the promotor DELTA BLOC UK LtdUnit A Fox WayTrinity Business ParkWaldorf WayWakefield, WF2 8EETel. 0845 30 40 705Fax. 0845 30 40 706email: [email protected] site: www.deltabloc.co.uk

H2 Contact the promotor Contact the promotor DELTA BLOC UK LtdUnit A Fox WayTrinity Business ParkWaldorf WayWakefield, WF2 8EETel. 0845 30 40 705Fax. 0845 30 40 706email: [email protected] site: www.deltabloc.co.uk

N2 Contact the promotor Contact the promotor DELTA BLOC UK LtdUnit A Fox WayTrinity Business ParkWaldorf WayWakefield, WF2 8EETel. 0845 30 40 705Fax. 0845 30 40 706email: [email protected] site: www.deltabloc.co.uk

H2 W2 B DELTA BLOC UK LtdUnit A Fox WayTrinity Business ParkWaldorf WayWakefield, WF2 8EETel. 0845 30 40 705Fax. 0845 30 40 706email: [email protected] site: www.deltabloc.co.uk

N2 Contact promoter Contact promoter DELTA BLOC UK LtdUnit A Fox WayTrinity Business ParkWaldorf WayWakefield, WF2 8EETel. 0845 30 40 705Fax. 0845 30 40 706email: [email protected] site: www.deltabloc.co.uk

N2 Contact promoter Contact promoter DELTA BLOC UK LtdUnit A Fox WayTrinity Business ParkWaldorf WayWakefield, WF2 8EETel. 0845 30 40 705Fax. 0845 30 40 706email: [email protected] site: www.deltabloc.co.uk

DELTA BLOC EP 80B/EP 80B-E to double sided OBB transition

DB80AS-E to rigid structures 500mm wide

EP80B-E to rigid structures over 1.0m wide

EP80B to double sided OBB

DELTA BLOC EP-REPDELTA BLOC EP-CJODELTA BLOC EP-EOS

DELTA BLOC EP 80B/EP 80B-E to single sided OBB transition

Transitions 54 January 2015

Page 58: List of EN1317 Compliant RRS January 2015

Transition Name Containment Level Working Width Class Impact Severity Level Name and Address of Promoter Comments

H2 W2 B DELTA BLOC UK LtdUnit A Fox WayTrinity Business ParkWaldorf WayWakefield, WF2 8EETel. 0845 30 40 705Fax. 0845 30 40 706email: [email protected] site: www.deltabloc.co.uk

H2 W2 B DELTA BLOC UK LtdUnit A Fox WayTrinity Business ParkWaldorf WayWakefield, WF2 8EETel. 0845 30 40 705Fax. 0845 30 40 706email: [email protected] site: www.deltabloc.co.uk

H2 W2 B DELTA BLOC UK LtdUnit A Fox WayTrinity Business ParkWaldorf WayWakefield, WF2 8EETel. 0845 30 40 705Fax. 0845 30 40 706email: [email protected]

Web site: www.deltabloc.co.ukH2 W2 B DELTA BLOC UK Ltd

Unit A Fox WayTrinity Business ParkWaldorf WayWakefield, WF2 8EETel. 0845 30 40 705Fax. 0845 30 40 706email: [email protected] site: www.deltabloc.co.uk

H2 W2 B DELTA BLOC UK LtdUnit A Fox WayTrinity Business ParkWaldorf WayWakefield, WF2 8EETel. 0845 30 40 705Fax. 0845 30 40 706email: [email protected] site: www.deltabloc.co.uk

H2 W2 B DELTA BLOC UK LtdUnit A Fox WayTrinity Business ParkWaldorf WayWakefield, WF2 8EETel. 0845 30 40 705Fax. 0845 30 40 706email: [email protected] site: www.deltabloc.co.uk

DELTA BLOC EP 80B/EP 80B-E to DELTA BLOC DB 80AS-E transition

DELTA BLOC EP 80B/EP 80B-E to DELTA BLOC DB 80AS-E transition

DELTA BLOC EP 80B/EP 80B-E to DELTA BLOC DB 80AS-E transition

EP 80B/EP 80B-E to rigid structure transition

DELTA BLOC EP 80B/EP 80B-E to CSB transition

DELTA BLOC EP 80B/EP 80B-E to CSB transition

Transitions 55 January 2015

Page 59: List of EN1317 Compliant RRS January 2015

Transition Name Containment Level Working Width Class Impact Severity Level Name and Address of Promoter Comments

H2 W2 B DELTA BLOC UK LtdUnit A Fox WayTrinity Business ParkWaldorf WayWakefield, WF2 8EETel. 0845 30 40 705Fax. 0845 30 40 706email: [email protected] site: www.deltabloc.co.uk

H2 W2 B DELTA BLOC UK LtdUnit A Fox WayTrinity Business ParkWaldorf WayWakefield, WF2 8EETel. 0845 30 40 705Fax. 0845 30 40 706email: [email protected] site: www.deltabloc.co.uk

N2 Contact the promotor Contact the promotor Highway Care Ltd.The HighlandsDetling HillDetling MaidstoneKentME14 3HTTel. 01622 734215Fax. 01622 735106email: [email protected] site: www.highwaycare.co.uk

N2 Contact the promotor Contact the promotor Highway Care Ltd.The HighlandsDetling HillDetling MaidstoneKentME14 3HTTel. 01622 734215Fax. 01622 735106email: [email protected] site: www.highwaycare.co.uk

N2 Contact the promotor Contact the promotor Highway Care Ltd.The HighlandsDetling HillDetling MaidstoneKentME14 3HTTel. 01622 734215Fax. 01622 735106email: [email protected] site: www.highwaycare.co.uk

Single row DELTA BLOC EP 80B/EP 80B-E to double row DELTA BLOC EP 80B/EP 80B-E (bifurcation)

Single row DELTA BLOC EP 80B/EP 80B-E to double row DELTA BLOC DB 80AS-E (bifurcation)

Barrierguard Gate connection to GA/72 and GA/74

S.A.B Gate connection to GA/74

Barrierguard 800 connection to GA/72 and GA/74

Transitions 56 January 2015

Page 60: List of EN1317 Compliant RRS January 2015

Transition Name Containment Level Working Width Class Impact Severity Level Name and Address of Promoter Comments

N2 Contact the promotor Contact the promotor Highway Care Ltd.The HighlandsDetling HillDetling MaidstoneKentME14 3HTTel. 01622 734215Fax. 01622 735106email: [email protected] site: www.highwaycare.co.uk

N1 Contact the promotor Contact the promotor Hill and SmithSpringvale Business and Industrial ParkBilstonWolverhamptonWest MidlandsWV14 0QLTel: 01902 499400Fax: 01902 499419Email: [email protected]: www.hill-smith.co.uk

N2 W2 B Hill and SmithSpringvale Business and Industrial ParkBilstonWolverhamptonWest MidlandsWV14 0QLTel: 01902 499400Fax: 01902 499419Email: [email protected]: www.hill-smith.co.uk

N1 W2 B Hill and SmithSpringvale Business and Industrial ParkBilstonWolverhamptonWest MidlandsWV14 0QLTel: 01902 499400Fax: 01902 499419Email: [email protected]: www.hill-smith.co.uk

N2 W2 Contact the promotor Hill and SmithSpringvale Business and Industrial ParkBilstonWolverhamptonWest MidlandsWV14 0QLTel: 01902 499400Fax: 01902 499419Email: [email protected]: www.hill-smith.co.uk

Tranzflex 80 N2W2 FlexBeam to Varley and Gulliver N1W2 VGSN 800 vertical infill parapet Transition

Note: Only permitted for use on roads where a speed limit

of less than 50 mph is operative.

Tranzflex 110 N2 Flexbeam to N1 W1 VGSN 500 Parapet Transition

Tranzflex 115 N2W2 Flexbeam to Varley and Gulliver N2W2 VGSN 900 series parapet

Single Sided Xtension P4 terminal (X-Tension 110 Single Sided P4 Terminal) to Flexbeam Transition

Tranzflex 100 N2 Flexbeam to Single Sided H1/H2 Flexbeam Plus Transition

Note: Only permitted for use on roads where a speed limit

of less than 50 mph is operative.

Transitions 57 January 2015

Page 61: List of EN1317 Compliant RRS January 2015

Transition Name Containment Level Working Width Class Impact Severity Level Name and Address of Promoter Comments

N2 W2 B Hill and SmithSpringvale Business and Industrial ParkBilstonWolverhamptonWest MidlandsWV14 0QLTel: 01902 499400Fax: 01902 499419Email: [email protected]: www.hill-smith.co.uk

N1 W2 B Hill and SmithSpringvale Business and Industrial ParkBilstonWolverhamptonWest MidlandsWV14 0QLTel: 01902 499400Fax: 01902 499419Email: [email protected]: www.hill-smith.co.uk

N2 W2 B Hill and SmithSpringvale Business and Industrial ParkBilstonWolverhamptonWest MidlandsWV14 0QLTel: 01902 499400Fax: 01902 499419Email: [email protected]: www.hill-smith.co.uk

N2 W2 Refer to Promotor Hill and SmithSpringvale Business and Industrial ParkBilstonWolverhamptonWest MidlandsWV14 0QLTel: 01902 499400Fax: 01902 499419Email: [email protected]: www.hill-smith.co.uk

N2 W2 Refer to Promotor Hill and SmithSpringvale Business and Industrial ParkBilstonWolverhamptonWest MidlandsWV14 0QLTel: 01902 499400Fax: 01902 499419Email: [email protected]: www.hill-smith.co.uk

Tranzflex 120 N2 Flexbeam to N2 W1 VGSN 1000 Parapet Transition

Tranzflex 130 N2 Flexbeam to N1 W2 VGAN 500 Parapet Transition

Tranzflex 140 N2 Flexbeam to N2 W2 VGAN 1000 Parapet Transition

Tranzflex 150 N2 Flexbeam to H2 W3 VGSH 2000 Parapet Transition

Tranzflex 155 N2W2 Flexbeam to Varley and Gulliver H2W1 VarleyGuard parapet transition

Note: Only permitted for use on roads where a speed limit

of less than 50 mph is operative.

Transitions 58 January 2015

Page 62: List of EN1317 Compliant RRS January 2015

Transition Name Containment Level Working Width Class Impact Severity Level Name and Address of Promoter Comments

N2 W2 Refer to Promotor Hill and SmithSpringvale Business and Industrial ParkBilstonWolverhamptonWest MidlandsWV14 0QLTel: 01902 499400Fax: 01902 499419Email: [email protected]: www.hill-smith.co.uk

N2 W2 Refer to Promotor Hill and SmithSpringvale Business and Industrial ParkBilstonWolverhamptonWest MidlandsWV14 0QLTel: 01902 499400Fax: 01902 499419Email: [email protected]: www.hill-smith.co.uk

N2 W3 B Hill and SmithSpringvale Business and Industrial ParkBilstonWolverhamptonWest MidlandsWV14 0QLTel: 01902 499400Fax: 01902 499419Email: [email protected]: www.hill-smith.co.uk

N2 W4 B SafeRoad UK Ltd.Dragonby ValeEnterprise ParkMannaberg WayScunthorpeNorth LincolnshireDN15 8XFTel. 01724 289119Fax. 01724 281478email: [email protected]

N2 Contact the promotor Contact the promotor SafeRoad UK Ltd.Dragonby ValeEnterprise ParkMannaberg WayScunthorpeNorth LincolnshireDN15 8XFTel. 01724 289119Fax. 01724 281478email: [email protected]

Tranzflex 160 N2 Flexbeam to H4a W3 V6Guard Parapet Transition

Tranzflex 170 N2 Flexbeam to Varley and Gulliver H4aW4 VGSN 4000 Parapet Transition

Tranzflex 200 N2 W4 Double sided FlexBeam to H2 W5 Double sided Bri-Flex Transition

Megaflex Transition (H2W1 MegaGuard parapet to N2W4 safety fence)

MegaFlex to BACO parapet transition

Transitions 59 January 2015

Page 63: List of EN1317 Compliant RRS January 2015

Transition Name Containment Level Working Width Class Impact Severity Level Name and Address of Promoter Comments

N2 Contact the promotor Contact the promotor SafeRoad UK Ltd.Dragonby ValeEnterprise ParkMannaberg WayScunthorpeNorth LincolnshireDN15 8XFTel. 01724 289119Fax. 01724 281478email: [email protected]

N2 Contact the promotor Contact the promotor SafeRoad UK Ltd.Dragonby ValeEnterprise ParkMannaberg WayScunthorpeNorth LincolnshireDN15 8XFTel. 01724 289119Fax. 01724 281478email: [email protected]

N2 Contact the promotor Contact the promotor SafeRoad UK Ltd.Dragonby ValeEnterprise ParkMannaberg WayScunthorpeNorth LincolnshireDN15 8XFTel. 01724 289119Fax. 01724 281478email: [email protected]

N2 Contact the promotor Contact the promotor SafeRoad UK Ltd.Dragonby ValeEnterprise ParkMannaberg WayScunthorpeNorth LincolnshireDN15 8XFTel. 01724 289119Fax. 01724 281478email: [email protected]

N1 Contact the promotor Contact the promotor SafeRoad UK Ltd.Dragonby ValeEnterprise ParkMannaberg WayScunthorpeNorth LincolnshireDN15 8XFTel. 01724 289119Fax. 01724 281478email: [email protected]

MegaFlex to BD52/93 steel parapet transition

MegaFlex to 100 series parapet transition

MegaFlex to Alcan parapet transition

MegaFlex to Lindley parapet transition

MegaFlex to Phoenix N1 parapet transition Note: Only permitted for use on roads where road works are being undertaken and a speed limit of less than 50

mph is operative.

Transitions 60 January 2015

Page 64: List of EN1317 Compliant RRS January 2015

Transition Name Containment Level Working Width Class Impact Severity Level Name and Address of Promoter Comments

N2 Contact the promotor Contact the promotor SafeRoad UK Ltd.Dragonby ValeEnterprise ParkMannaberg WayScunthorpeNorth LincolnshireDN15 8XFTel. 01724 289119Fax. 01724 281478email: [email protected]

N2 Contact the promotor Contact the promotor SafeRoad UK Ltd.Dragonby ValeEnterprise ParkMannaberg WayScunthorpeNorth LincolnshireDN15 8XFTel. 01724 289119Fax. 01724 281478email: [email protected]

N1 Contact the promotor Contact the promotor SafeRoad UK Ltd.Dragonby ValeEnterprise ParkMannaberg WayScunthorpeNorth LincolnshireDN15 8XFTel. 01724 289119Fax. 01724 281478email: [email protected]

N2 Contact the promotor Contact the promotor SafeRoad UK Ltd.Dragonby ValeEnterprise ParkMannaberg WayScunthorpeNorth LincolnshireDN15 8XFTel. 01724 289119Fax. 01724 281478email: [email protected]

H2 Contact the promotor Contact the promotor SafeRoad UK Ltd.Dragonby ValeEnterprise ParkMannaberg WayScunthorpeNorth LincolnshireDN15 8XFTel. 01724 289119Fax. 01724 281478email: [email protected]

MegaFlex to SN2 parapet transition

1.5m high MegaGuard to H4a Concrete Barrier connection

Note: Only permitted for use on roads where road works are being undertaken and a speed limit of less than 50

mph is operative.

MegaFlex to Phoenix N2 parapet transition

MegaFlex to Sicuro parapet transition

MegaFlex to SN1 parapet transition

Transitions 61 January 2015

Page 65: List of EN1317 Compliant RRS January 2015

Transition Name Containment Level Working Width Class Impact Severity Level Name and Address of Promoter Comments

H1 W4 Contact the promotor SafeRoad UK Ltd.Dragonby ValeEnterprise ParkMannaberg WayScunthorpeNorth LincolnshireDN15 8XFTel. 01724 289119Fax. 01724 281478email: [email protected]

H2 Contact the promotor Contact the promotor SafeRoad UK Ltd.Dragonby ValeEnterprise ParkMannaberg WayScunthorpeNorth LincolnshireDN15 8XFTel. 01724 289119Fax. 01724 281478email: [email protected]

N2 W3 B Tata Steel Construction ProductsLlanwern WorksNewportSouth WalesNP19 4QZTel. 01633 290011 email: [email protected]

N2 W3 B Tata Steel Tubes EuropePO Box 101Weldon RoadCorbyNorthantsNN17 5UATel. 01536 402121email:[email protected]

N2 W1 B Tata Steel Tubes EuropePO Box 101Weldon RoadCorbyNorthantsNN17 5UATel. 01536 402121email:[email protected]

N2 W2 B Tata Steel Tubes EuropePO Box 101Weldon RoadCorbyNorthantsNN17 5UATel. 01536 402121email:[email protected]

MegaGuard to concrete structure connection

H1W4 MegaRail to H1W4 DROBB safety fence transition

Vetex N2W2 Safety Fence to Protect 365 N2W3 or N2W4 Transition

Protect 365 N2 Safety Fence to Protect 365 N2 Parapet transition

Protect 365 N2 to H4a Steel Parapet Transition

Protect 365 H4a Parapet to Protect 365 N2 Parapet Transition

Transitions 62 January 2015

Page 66: List of EN1317 Compliant RRS January 2015

Transition Name Containment Level Working Width Class Impact Severity Level Name and Address of Promoter Comments

N2 W2 B Tata Steel Tubes EuropePO Box 101Weldon RoadCorbyNorthantsNN17 5UATel. 01536 402121email:[email protected]

H2 W5 B Technische Sichereits-Systeme (TSS) GmbHAlfred Schutte-Allee 10D-50679 CologneGermanyTel. +49 221 980601Fax. 49 221 9806490email: [email protected]

N2 Contact the promotor Contact the promotor Varley and Gulliver LtdAlfred StreetSparkbrookBirminghamB12 8JRTel. (0121) 773 2441email: [email protected]

N1 Contact the promotor Contact the promotor Varley and Gulliver Ltd

Alfred StreetSparkbrookBirminghamB12 8JRTel. (0121) 773 2441email: [email protected]

Connection Between VGSH 4000 and VGSN 1000 VRS systems

Connection Between VGSH 4000 and VGSN 800 VRS systems

END OF TRANSITION SECTION - RETURN TO CONTENTS

Vetex N2 Safety Fence to Protect 365 N2 Safety Fence Transition

Transitions detailed in the NPSBS (Revision 1) are deemed acceptable for use on the Highways Agency Trunk Road Network, without the need for a Departure from Standard submission, as

TSS Vario - Transition between German B-profile safety fence and TSS Softbaer concrete barrier

Transitions 63 January 2015

Page 67: List of EN1317 Compliant RRS January 2015

SAFETY BARRIER GATES

Safety Barrier Gate Name Containment Level

Working Width Class Impact Severity Level

Name and Address of Promoter Comments

H1 W5 B Asset International (A Division of Hill and Smith)Springvale AvenueBilstonWolverhamptonWV14 0QLTel. 01902 499402Fax. 01902 402104email: [email protected] Site: www.asset-vrs.co.uk

H2 W7 B SafeRoad UK Ltd.Dragonby ValeEnterprise ParkManaberg WayScunthorpeNorth LincolnshireDN15 8XFTel. 01724 289119email: [email protected]

H2 For 2-3 elements: B Snoline spa, represented by:W4 Highway Care Ltd.

The HighlandsFor 4-25 elements: B Detling Hill

W6 Detling HillMaidstone Kent ME14 3HTTel. 01622 734215

H1 Fax. 01622 735106email: [email protected] site: www.highwaycare.co.uk

The following Safety Barrier Gates have been successfully tested to meet the requirements of BS EN 1317- 1 and 2 and DD ENV 1317 - 4 and have been accepted for use on the Highways Agency Trunk Road Network for the Containment Performance Class and Working Width Class stated below.

The Safety Barrier Gates shall comply with the manufacturer's specification, component descriptions and Installation procedures. Further information on Impact Severity Levels for the product and copies of documents and drawings can be obtained from the Promoter.

Essential characteristic information only is provided and confirmation is required that the system selected complies fully with all HA contractual conditions and requirements as detailed in the DMRB, MCHW, and any contract specific or site specific documentation.

Installers shall have successfully undertaken suitable training for the system to be installed.

SOLOGUARD Emergency and Maintenance Crossing Point System

Gateguard Removal Barrier System

S-A-B Class H2 Gate (For emergency and maintenance cross over points)

Safety Barrier Gates 64 January 2015

Page 68: List of EN1317 Compliant RRS January 2015

Safety Barrier Gate Name Containment Level

Working Width Class Severity Level Name and Address of Promoter Comments

H2 W2 Refer to Promoter Asset International (A Division of Hill and Smith)Springvale AvenueBilston

WolverhamptonWV14 0QLTel. 01902 499402

Fax. 01902 402104email: [email protected] Site: www.asset-vrs.co.uk

H2 W2 Refer to Promoter Britpave Barrier Systems LtdAtrium CourtThe RingBracknellBerkshireRG12 1BWTel. 01344 393300email: [email protected] site: www.britpavebarriersystems.com

H2 W6 B DELTA BLOC UK LtdUnit A Fox WayTrinity Business ParkWaldorf WayWakefield, WF2 8EETel. 0845 30 40 705Fax. 0845 30 40 706email: [email protected] site: www.deltabloc.co.uk

H2 W5 A DELTA BLOC UK LtdUnit A Fox WayTrinity Business ParkWaldorf WayWakefield, WF2 8EETel. 0845 30 40 705Fax. 0845 30 40 706email: [email protected] site: www.deltabloc.co.uk

The following Safety Barrier Gates have the same profile and performance characteristics of their compliant BS EN 1317 safety barriers which are deemed acceptable for use on the Highways Agency Trunk Road Network for the Containment Performance Class and Working Width Class stated below.

The Safety Barrier Gates shall comply with the manufacturer's specification, component descriptions and Installation procedures. Further information on Impact Severity Levels for the product and copies of documents and drawings can be obtained from the Promoter.

Steel Step Corridor System ( For Emergency and Maintenance Crossing Points)

Steel Step Barrier Gate (For Emergency Crossing Points)

DB SafeGate DB80 6m K180

DB SafeGate DB100S 6m K220

Safety Barrier Gates 65 January 2015

Page 69: List of EN1317 Compliant RRS January 2015

Safety Barrier Gate Name Containment Level

Working Width Class Severity Level Name and Address of Promoter Comments

H2 W6 C DELTA BLOC UK LtdUnit A Fox WayTrinity Business ParkWaldorf WayWakefield, WF2 8EETel. 0845 30 40 705Fax. 0845 30 40 706email: [email protected] site: www.deltabloc.co.uk

N2 W5 Refer to Promoter Highway Care Ltd.The Highlands

H2 W8 Refer to Promoter Detling HillDetling MaidstoneKentME14 3HTTel. 01622 734215Fax. 01622 735106email: [email protected] site: www.highwaycare.co.uk

H2 W2 Refer to Promoter SafeRoad UK Ltd.Dragonby ValeEnterprise ParkManaberg WayScunthorpeNorth LincolnshireDN15 8XFTel. 01724 289119email: [email protected]

END OF SAFETY BARRIER GATE SECTION - RETURN TO CONTENTS

SafeRoad Steel Step Barrier Gate

Barrierguard 800 Gate (For Emergency and Maintenance Crossing Points), including connection to corrugated W-beam safety fencing

The installation of safety barriers with an ASI Class of C must be with the

agreement of the Overseeing Organisation (refer to TD19/06,

Sections 3.6 and 3.7).

DB SafeGate DB90 Step 6m K220

Safety Barrier Gates 66 January 2015

Page 70: List of EN1317 Compliant RRS January 2015

MISCELLANEOUS

Product Impact Severity Level Name and Address of Promoter Comments

A Highway Care Ltd.The HighlandsDetling HillDetling MaidstoneKentME14 3HTTel. 01622 734215Fax. 01622 735106email: [email protected] site: www.highwaycare.co.ukHill and SmithSpringvale Business and Industrial ParkBilstonWolverhamptonWest MidlandsWV14 0QLTel: 01902 499400Fax: 01902 499419Email: [email protected]: www.hill-smith.co.uk

A SafeRoad UK Ltd.Dragonby ValeEnterprise ParkManaberg WayScunthorpeNorth Lincolnshire

H1 DN15 8XFTel. 01724 289119email: [email protected]

As per the host safety barrier

The following products have been accepted for use on the Highways Agency Road Network and are for use in conjunction with vehicle restraint systems.

Essential characteristic information only is provided and confirmation is required that the system selected complies fully with all HA contractual conditions and requirements as detailed in the DMRB, MCHW, and any contract specific or site specific documentation.

BikeGuard (Motorcyclist Protection System fitted to safety barriers)

BikeGuard may be fitted to any UK system listed in the Non-Proprietary Safety Barrier Systems (NPSBS). It may also be fitted to any other system in the Highways Agency Approved Road Restraint

System List providing that Highway Care Limited first obtains the approval of the Promoter/Manufacturer of the safety barrier system

BikeGuard is to be attached to.

FlexGuard (Motorcyclist Protection System fitted to safety barriers)

MegaRail es with a motorcyclist protection device

Motorcyclist Protection System fitted to TCB, OBB, FlexBeam/FlexBeam Plus (both single and double sided versions of

these systems), the Hill and Smith H1/H2 safety barrier, and the Briflex vehicle restraint system.

N2W2, CE marked system

Miscellaneous 67 January 2015

Page 71: List of EN1317 Compliant RRS January 2015

Product Impact Severity Level Name and Address of Promoter Comments

A SafeRoad UK Ltd.Dragonby ValeEnterprise ParkManaberg WayScunthorpeNorth LincolnshireDN15 8XFTel. 01724 289119email: [email protected]

N2W2, CE marked system

END OF MISCELLANEOUS SECTION - RETURN TO CONTENTS

ESP 4.0 UFS Bikeguard

Miscellaneous 68 January 2015

Page 72: List of EN1317 Compliant RRS January 2015

TRCUK MOUNTED ATTENUATORS (LORRY MOUNTED CRASH CUSHIONS)

TMA/LMCC Name Name and Address of Promoter CommentsAcklea Ltd.Unit 1Clark AvenuePorte Marsh Industrial EstateClaneWiltshireSN11 9RDTel. 01249 822 600Fax. 01249 820 111email: [email protected] Highway Products Ltd.RiversideMarket HarboroughLeicestershireLE16 7PXTel. 08707 475969Fax. 08707 475970email: [email protected]

The following Truck Mounted Atennuators (TMAs) [also known as Lorry Mounted Crash Cushions (LMCCs)] meet the requirements of TD 49/07 and hence, have demonstrated compliance with a 1500kg car impact at the speed of

the performance class. They may be used on the Highway Agency Trunk Road Network provided that a special dispensation order known as a Vehicle Special Order (VSO) is obtained from the Department for Transport.

In addition a Vehicle Inspectorate Form VTG 10 will need to be filed if the TMA is fitted with an auto impact brake system.

The TMA shall comply with the manufacturer's Specification, component descriptions and Installation procedures. Copies of documents and drawings can be obtained from the Promoter.

Scorpion Lorry Mounted Crash Cushion

MPS-350 Lorry Mounted Crash Cushion For use on roads with a speed limit of 70mph or less

For use on roads with a speed limit of 70mph or less

Lorry Mounted Crash Cushions 69 January 2015

Page 73: List of EN1317 Compliant RRS January 2015

TMA/LMCC Name Name and Address of Promoter CommentsKing Highway Products Ltd.RiversideMarket HarboroughLeicestershireLE16 7PXTel. 08707 475969Fax. 08707 475970email: [email protected] Highway Products Ltd.H1Market HarboroughLeicestershireLE16 7PXTel. 08707 475969Fax. 08707 475970email: [email protected] Highway Products InternationalCrown House, Crown StreetIpswichIP1 3HS Fax: 01473 221106Email: [email protected]: www.energyabsorption.comTrinity Highway Products InternationalCrown House, Crown StreetIpswichIP1 3HSTel: 01473 221105Fax: 01473 221106Email: [email protected]: www.energyabsorption.com

Vorteq™ Trailer

SafeStop Lorry Mounted Crash Cushion

MPS-350 Lorry Mounted Crash Cushion

For use on roads with a speed limit of 70mph or less

For use on roads with a speed limit of 70mph or less

For use on roads with a speed limit of 70mph or less

For use on roads with a speed limit of 70mph or less

Vorteq™ Trailer

Lorry Mounted Crash Cushions 70 January 2015

Page 74: List of EN1317 Compliant RRS January 2015

TMA/LMCC Name Name and Address of Promoter CommentsTrinity Highway Products InternationalCrown House, Crown StreetIpswichIP1 3HSTel: 01473 221105Fax: 01473 221106Email: [email protected]: www.energyabsorption.comVerdegroDistributed in the UK by:Highway Care Ltd.The HighlandsDetling HillDetling MaidstoneKentME14 3HTTel. 01622 734215Fax. 01622 735106email: [email protected] site: www.highwaycare.co.uk

END OF TMA/LMCC SECTION - RETURN TO CONTENTS

IP70 For use on roads with a speed limit of 70mph or less

For use on roads with a speed limit of 70mph or less

SafeStop Lorry Mounted Crash Cushion

Lorry Mounted Crash Cushions 71 January 2015