Technical Specifications of the S7-300 CPUs (1)CPU

Execution time in µs Bit instruction Word instruction Integer (+/-) Real (+/-)

User memory Work memory Load memory integr. Load memory extern

Addresses Bit memories Clock memories Timers Counters

Block Types/Number FBs FCs DB's

Size of process image I/O in bytes

max. I/O address area in bytes

Interfaces

314 IFM

0.3 - 0.61.22.050.0

32 KB48 KB(4 MB)

2048812864

128128127

124 each

752 each

MPI

315-2 DP

0.3 - 0.61.02.050.0

64 KB96 KB4 MB

2048812864

192192255

128 each

1024 each

MPI, DP

315

0.3 - 0.6 1.02.050.0

48 KB80 KB4 MB

2048812864

192192255

128 each

768 each

MPI

312 IFM

0.6 - 1.22.03.060.0

6 KB20 KB-

102486432

323263

32 each

32 each

MPI

314

0.3 - 0.61.22.050.0

24 KB40 KB4 MB

2048812864

128128127

128 each

768 each

MPI

313

0.6 - 1.22.03.060.0

12 KB20 KB4 MB

2048812864

128128127

128 each

32 each

MPI

316-2 DP

0.3 - 0.6 1.02.050.0

128 KB192 KB4 MB

2048812864

256512511

128 each

1024 each

MPI, DP

318-2 DP

0.10.10.10.6

512 KB64 KB4 MB

81928512512

102410242047

256 each (2048)

8192 each

MPI/DP, DP

Page 3: S7 bas-15

SIMATIC S7Siemens Engenharia e Service 2002. Todos os direitos reservados.

Data: 13/04/23Arquivo: S7-Bas-15.3

313

OB No.110203540-10080-82, 85, 87121,122

1536

8 KB8

4/4

4

1

1

22 bytes

CPU

Organization blocksFree cycleTime-of-day interruptsTime-delay interruptsCyclic interruptsHardware interruptsBackground executionStartupErrors, asynchronous

Errors, synchronous

Local data in bytes

max. block lengthBlock nesting depth per execution level

CommunicationMax. connectionsstatic/dynamic

Global data communi-cation via MPI:GD circles per CPU

Send GD packets per GD circle

Receive GD packet perGD circle

max. user data size of a packet

Technical Specifications of the S7-300 CPUs (2)314 IFM

OB No.110203540-10080-82, 85, 87121,122

1536

8 KB8

4/8

4

1

1

22 bytes

315-2 DP

OB No.110203540-10080-82, 8587121,122

1536

16 KB8

4/8

4

1

1

22 bytes

315

OB No.110203540-10080-82, 85,87121,122

1536

16 KB8

4/8

4

1

1

22 bytes

312 IFM

OB No.1---40-100-

-

512

8 KB8

4/2

4

1

1

22 bytes

316-2 DP

OB No.110203540-10080-82, 8587121,122

1536

16 KB8

4/8

4

1

1

22 bytes

318-2 DP

OB No.110,1120,2132,3540,4190100,10280-82, 8587121,122

4096(8192)

64 KB20

32

8

1

2

54 bytes

314

OB No.110203540-10080-82, 85, 87121,122

1536

8 KB8

4/8

4

1

1

22 bytes

Page 4: S7 bas-15

SIMATIC S7Siemens Engenharia e Service 2002. Todos os direitos reservados.

Data: 13/04/23Arquivo: S7-Bas-15.4

Technical Specifications of the S7-400 CPUs (1)CPU

Execution time in µs Bit instruction Word instruction Integer (+/-) Real (+/-)

User memory Work memory int. Load memory integr. Load memory extern

Addresses Byte memories Clock memories Timers Counters

Block Types/Number FBs FCs DB's

Size of process image I/O in bytes

max. I/O address area in bytes

Interfaces

414-3

0.10.10.10.6

2x 384 KB256 KB64 MB

8 K8256256

102410241023

8 K each

8 K each

MPI/DP2xDP

416-3

0.080.080.080.48

2x 1.6 MB256 KB64 MB

16 K8512512

204820484096

16 K each

16 K each

MPI/DP2x DP

416-2

0.080.080.080.48

2x 0.8 MB256 KB64 MB

16 K8512512

204820484096

16 K each

16 K each

MPI/DPDP

412-1

0.20.20.20.6

2x48 KB256 KB64 MB

4 K8256256

256256511

4 K each

4 K each

MPI/DP

414-2

0.10.10.10.6

2x128 KB256 KB64 MB

8 K8256256

102410241023

8 K each

8K each

MPI/DPDP

412-2

0.20.20.20.6

2x48 KB256 KB64 MB

4 K8256256

256256511

4 K each

4 K each

MPI/DPDP

417-4

0.10.10.10.6

2x2 MB256 KB64 MB

16 K8512512

614461448191

16 K each

16 K each

MPI/DP3x DP

417H

0.10.10.10.6

2x2 MB256 KB64 MB

16 K8512512

614461448191

16 K each

16 K each

MPI/DPDP

Page 5: S7 bas-15

SIMATIC S7Siemens Engenharia e Service 2002. Todos os direitos reservados.

Data: 13/04/23Arquivo: S7-Bas-15.5

CPU

Organization blocksFree cycleTime-of-day interruptsTime-delay interruptsCyclic interrupsHardware interruptsMulticomputingBackground executionStartupErrors, asynchronousErrors, synchronous

Local data in bytes

max. block lengthBlock nesting depthper execution level

CommunicationMax. connectionsstatic/dynamic

Global data communi-cation via MPI:GD circles per CPU

Send GD packets per GD circle

Receive GD packets perGD circle

max. user data size of a packet

Technical Specifications of the S7-400 CPUs (2)414-3

OB No.110-1320-2332-3540-436090100-10280-87121,122

8 KB

64 KB16

32

8

1

2

54 bytes

416-3

OB No.110-1720-2330-3840-476090100-10280-87121,122

16 KB

64 KB16

64

16

1

2

54 bytes

416-2

OB No.110-1720-2330-3840-476090100-10280-87121,122

16 KB

64 KB16

64

16

1

2

54 bytes

412-1

OB No.110,1120,2132,3540,416090100-10280-87121,122

4 KB

48 KB16

16

8

1

2

54 bytes

414-2

OB No.110-1320-2332-3540-436090100-10280-87121,122

8 KB

64 KB16

32

8

1

2

54 bytes

412-2

OB No.110,1120,2132,3540,416090100-10180-87121,122

4 KB

64 KB16

16

8

1

2

54 bytes

417-4

OB No.110-1720-2330-3840-476090100-10280-87121,122

32 KB

64 KB16

64

16

1

2

54 bytes

417H

OB No.110-1720-2330-3840-476090100,10280-87121,122

32 KB

64 KB24

64

16

1

2

54 bytes

Page 6: S7 bas-15

SIMATIC S7Siemens Engenharia e Service 2002. Todos os direitos reservados.

Data: 13/04/23Arquivo: S7-Bas-15.6

Main Differences to the S7-300

Larger memory and more I/Q/M/T/C

Addresses of input/output modules selectable

Can connect EUs from S5 and use S5 CP/IP modules

More system functions, e.g. programmed block communication

Block size up to 64KB and twice as many DBs

Complete restart and restart

Setpoint/actual comparison of configuration on startup

Modules can be removed without disconnecting the power supply

Several part process images

Priorities of OBs are parameter-assignable

Several OBs for cyclic, hardware and time-of-day interrupts

Block nesting up to 16 levels

Size of L Stack selectable for each execution level

4 accumulators

Multicomputimg

Page 7: S7 bas-15

SIMATIC S7Siemens Engenharia e Service 2002. Todos os direitos reservados.

Data: 13/04/23Arquivo: S7-Bas-15.7

Components of the S7- 400

CPUsCPUs

CPU 412-1, 412-2CPU 414-1, 414-2,CPU 416-2, 416-3CPU 417-4, 417H

RacksRacks

- Universal rack (UR 1/2) for use as CR and ER- Extension rack (ER 1/2)- Segmented central rack (CR2)

Signal modules (SM)Signal modules (SM)

- DI/DO 32,16,8 channels

- DO with relay output- AI/AO 16,8 channels- diagnostics-capable

modules

Communicationprocessors (CP)

Communicationprocessors (CP)

- Point-to-Point CP441-1, 1- channel CP441-2, 2- channel- Networks

Profibus Ethernet

Power Supplies (PS)Power Supplies (PS)

- AC 120V/230V, 4A/10A/20A- DC 24V, 4A/10A/20A

Function modules (FM)

Function modules (FM)

- Counting- Positioning- Closed-loop control

Page 8: S7 bas-15

SIMATIC S7Siemens Engenharia e Service 2002. Todos os direitos reservados.

Data: 13/04/23Arquivo: S7-Bas-15.8

Racks of the S7 - 400

UR1 / UR2(Universal Rack)

Type of Rack Centralrack

Extensionrack

Usable in

Yes Yes

P bus

ER1 / ER2(Extension Rack)

No Yes

P bus

K bus

CR2(Central Rack)

NoYes

P bus, Segment 1

K bus

P bus, Segment 2

Page 9: S7 bas-15

SIMATIC S7Siemens Engenharia e Service 2002. Todos os direitos reservados.

Data: 13/04/23Arquivo: S7-Bas-15.9

Module Parameters: Logical Addresses

Page 10: S7 bas-15

SIMATIC S7Siemens Engenharia e Service 2002. Todos os direitos reservados.

Data: 13/04/23Arquivo: S7-Bas-15.10

CPU Parameters: Startup

Page 11: S7 bas-15

SIMATIC S7Siemens Engenharia e Service 2002. Todos os direitos reservados.

Data: 13/04/23Arquivo: S7-Bas-15.11

CPU Parameters: Interrupts

Page 12: S7 bas-15

SIMATIC S7Siemens Engenharia e Service 2002. Todos os direitos reservados.

Data: 13/04/23Arquivo: S7-Bas-15.12

CPU Parameters: Local Data

Page 13: S7 bas-15

SIMATIC S7Siemens Engenharia e Service 2002. Todos os direitos reservados.

Data: 13/04/23Arquivo: S7-Bas-15.13

Configuring Multicomputing Operation

Page 14: S7 bas-15

SIMATIC S7Siemens Engenharia e Service 2002. Todos os direitos reservados.

Data: 13/04/23Arquivo: S7-Bas-15.14

SFC 35 for Synchronization in Multicomputing Operation

Parameter Declaration Data type Memory Description

JOB INPUT BYTE I, Q, M, D, L, Const. Task identifier (possible values: 1 to 15)

RET_VAL OUTPUT INT I, Q, M, D, L Return value (error code).

Page 15: S7 bas-15

SIMATIC S7Siemens Engenharia e Service 2002. Todos os direitos reservados.

Data: 13/04/23Arquivo: S7-Bas-15.15

Remove and Insert Interrupt

Module exists

Module available

Remove/Insert interrupt

Parameter assignment of module through the operating system

Removing amodule

Inserting amodule

max.

1s

max.

1s