Turning Business Drivers into [email protected]
Source: EMC Digital Universe with Research and Analysis by IDC, The Digital Universe of
Opportunities: Rich Data and the Increasing Value of the Internet of Things, April 2014.
MOBILE
Mobile “Connected Things” will generate27% of the Digital Universe by 2020
CLOUD
Less than 20% of the Digital Universe was
touchedby cloud in 2013. Cloud will touch 40% by 2020
BIG DATA
Organizations will need to ingest huge amounts of data quickly, reason over it and act on it in
real time
SOCIAL
Social networking is transforming the way
humans interact
Business Drivers…
How can a SI / VAD use Professional Services
to translate Mega Trends such as IoT, Cloud & Big Data
into real business?
IT is Exponential
• Network Traffic
• Data Storage
• Computing Power
• Electric Power & Air-Conditioning
Network traffic: 14 years of exponential data growth
690 TB/month in 2001578,000 TB/month in 2014
840x
Storage: The Law of Accelerating Returns - Kurzweil
Information generation
• 2009 = 50GB/s
• 2020 = 500GB/µs
• 10,000,000x increase
Ray Kurzweil has been described as “the restless genius” by the Wall Street Journal, and “the ultimate thinkingmachine” by Forbes magazine, ranking him #8 among entrepreneurs in the United States and calling him the“rightful heir to Thomas Edison”. PBS included Ray as one of 16 “revolutionaries who made America,” along withother inventors of the past two centuries.
The Singularity is NearRaymond Kurzweil, 2005, Viking
Introduced the ‘law of accelerating returns’ and extended Moore’s Law
Source: Ray Kurzweil
Computing Power & Electrical Power
Predicting the future of Data Centers is not easy…
1997 – the world’s fastest super-computer
SANDIA National Laboratories ‘ASCI RED’1.8 teraflops150m² raised floor800kW
2007Sony Playstation31.8 teraflops0.08m²190W
Compute power growth vs.
Electrical power consumption growth
1997 – the world’s fastest super-computer
SANDIA National Laboratories ‘ASCI RED’1.8 teraflops150m² raised floor800kW
Nov 2013, ChinaMilky Way-233.86 PetaFLOPS (55 peak)17MW720m2
Performance: 20,000x 1997Power: 20 x 1997
Source: www.top500.org
Infrastructure takes energy…
Time magazine reported that it
takes 0.0002kWh to stream 1
minute of video from the YouTube
data centre…
Based on Jay Walker’s recent
TED talk, 0.01kWh of energy is
consumed on average in carrying
1MB over the Internet.
The average Internet device
energy consumption is around
0.001kWh for 1 minute of video
streaming
For 1.6B downloads of this 17MB
file and streaming for 4.13 mins
gives the overall energy for this
one pop video in just one year…
Source: Prof. Ian Biterlin
Gangnam style consumed 298GWh in just one year...
• 35MW of 24/7/365 power generation
• 100 million Litres fuel oil
• 250,000 Tons CO2
• 80,000 UK car years
Translating trends into business
• Exponential Growth requires Datacenter infrastructure
• Datacenter’s Infrastructure Needs to be Resilient, Efficient & Agile
• High Speed Networks – Easy transition to 40G/100G
• Efficiency with rigorous air flow management
• Data center Assessment
• Data center Commissioning
• Data center Relocation
• Data center Upgrade
• CFD Simulation
• Data center Integration
Use Professional Services to translate mega trends to business
Data Center Assessment: Making the case for containment
Tc Crac
Negative Pressure
Bypass
Air
Ts server in
Th server out
Th
Return
Air
Tf Floor
Air mix
Tr Return
Show that 50%-70% of the cold air generated is ByPass Air
16
Panduit Vertical Exhaust Ducting
• Vertical Exhaust Duct (VED) Cabinets (aka Chimney cabinets) are used to provide hot exhaust containment in data centers.
• Used by Intel Israel
• Approved by Intel Globally
17
Panduit Net-Contain™
Aisle Containment Systems
Cold Aisle Containment
• In an old data center improved PUE from
1.75 to 1.56 using Cold aisle containment
• ROI: one year
Sell the system: Airflow Management
Sell the system: Migration to 40G/100G
Pan MPO Push-Pull LC HD Flex
Our Industry is dominated by Paranoia
New Datacenter? How do you guarantee Resiliency?
Data Center Commissioning
• Install 1KW-4KW server emulators
• Dual PS, 90 CFM/KW
• Install Synapsense/Panduit Wireless sensors
• 3 in front of cabinet
• 3 in rear of cabinet
• Install real Time monitoring software
• Set up a safety command post
• Run the test scripts
All rights reserved
Data Center Commissioning ServiceTest & Prove the Datacenter’s resiliency…
• Tests the physical infrastructure under real load
• True real-life verification of:
• Air-conditioning ( Capacity, air delivery)
• Power
• Redundancy
• Alarms and software
• Energy efficiency
• Reduce downtime & Reduce OPEX
• Service played a key role in winning strategic datacenter projects