2a_Customer Quote Excl Rates Items Shown_1

Preview:

DESCRIPTION

Canon

Citation preview

======= Q U O T A T I O N =======

GAUTENG

QTRATEN1

Tel: 011 795-3733 Fax: 011 795-3059

ILIAD GAUTENG Salesman: ()Designed By: Robert Spagna

15 Jun 2015

============ M I T E K DESIGN DETAILS ============ROOF COVER: MARLEY MONARCH - 0.55 KN/M2@760CC

TCDL : 0.55 kN/m² BCDL : 0.14 kN/m²

ROOF PITCH : 22.00 Deg" MAX OVERHANG : 670 mm

Roof Area: 223.31 m² MAX BATTEN CENTRES: 320 mm

Floor Area: 171.78 m² MAX TRUSS CENTRES: 760 mm

Customer : CUSTOMER 1 Address: DAWSON GRANT

Job Title: STD 40

JOB NUMBER: 15534R

Roof Trusses'A001' Trusses Ref. Type Span TC Pitch Overhang Ply Qty. Sell Price

JACK 2647 22.0 712 0 10CJ1

DUO 5495 22.0 0 712 2-Ply 1G1

JACK 6805 15.9 930 0 3H1

JACK 5857 15.9 36 0 1H2

HIP 8370 22.0 712 0 1HG2

HIP 8370 22.0 712 712 1HG1

HIP 8370 22.0 712 712 2HT1

JACK 1887 22.0 712 0 4OJ1

JACK 1912 22.0 712 0 4OJ2

JACK 2647 22.0 712 0 3PJG1

JACK 2647 22.0 712 0 1PJG2

JACK 1127 22.0 712 0 4R1

JACK 367 22.0 712 0 7R2

JACK 367 22.0 0 0 1R3

JACK 64 22.0 255 0 6R4

DUO 8370 22.0 712 712 14T1

DUO 5495 22.0 712 712 5T2

VALLEY 3975 22.0 0 0 1V1

VALLEY 2455 22.0 0 0 1V2

VALLEY 935 .0 0 0 1V3

Sub-total for 'A001' Trusses R 22125.46

R 22125.46Sub-Total for Roof TrusseseCo Products

:M12 x 120 Long MS Bolt 8eaM12 x 100 Long MS Bolt

16ea36 x 36 x 4mm Square Washers

:Purlin Clip - Left 2eaPurlin Clip - Left Hand

2eaM12 x 65 Long MS Bolt

:M12 x 120 Long MS Bolt 16eaM12 x 100 Long MS Bolt

18ea36 x 36 x 4mm Square Washers

:Purlin Clip - Left 12eaPurlin Clip - Left Hand

:Purlin Clip - Right 12eaPurlin Clip - Right Hand

17piecesSpeedbrace - 3.6m lengths

1rollsBracing Strap - 10m rolls

3kgPermfix 35 x 3.15mm Blue

:38mm Mini Hanger P 3ETH38x1MP

======= Q U O T A T I O N =======ILIAD GAUTENG Salesman: ()

Designed By: Robert SpagnaJOB NUMBER: 15534R15 Jun 2015

:38mm Short Hanger P 16ETH38x1SP

:HFA90V2 Cleat 1HFA90V2

:Universal Nailed 8UNAIL

R 1657.95Sub-Total for eCo ProductsBracing

:38x114 (5) SAP - M 5mT Bracing

R 75.00Sub-Total for BracingR 120.00Transport Costs

Total Trusses/eCo Products/Bracing Price R 23978.41Sundry Timbers

:38x38 (5) SAP - S 181mBattens

:38x38 (5) SAP - M 271mBattens

:38x38 (5) SAP - L 451mBattens

:38x38 (5) SAP - S 3mValley Abutment Block

:38x50 (5) SAP - L 62mTilting Fillet

:38x76 (5) SAP - S 55mWallplates

:38x38 (5) SAP - M 17mTimber Valley Runners

R 6404.76Sub-Total for Sundry TimbersAdditional Sundries

18ea12 x 225 x 3.6m Fascia Boards

4ea12 x 225 Corner Jointers

18ea12 x 225 Jointers

3ea80 x 200 x 3.0m S.less Barge

3ea80 x 200 Jointers

8rollGundle Underlay

16kg75mm nails

12kg100mm nails

:3.0m Galv. Valley Flashings 462g 2ea3.0m Galv. Valley Lining

R 4834.25Sub-Total for Additional SundriesRoof Covering

:Double Roman Standard 2590eaDouble Roman Standard Terracot

3eaHip Starter Tile - Standard

110eaTapered Ridge Tile - Standard

:Transport - Marley 2710eaTransport - Marley Monarch & D

4kgOxide - Standard

R 20401.82Sub-Total for Roof Covering

TOTAL R 55619.24VAT @ 14.0% R 7786.69

TOTAL INCLUDING VAT R 63405.93

======= Q U O T A T I O N =======ILIAD GAUTENG Salesman: ()

Designed By: Robert SpagnaJOB NUMBER: 15534R15 Jun 2015

Additional Notes:

ILIAD GAUTENG is a licenced MiTek Industries SA fabricator and a proud member of the ITC SA.

PREFABRICATED MiTeK TIMBER ROOF TRUSSES DESIGNED IN ACCORDANCE WITH PART "A" AND "L" OF THE NATIONAL BUILDINGREGULATIONS. INCLUDING ROOF LAYOUT DRAWINGS OF TRUSSES AND ROOF STRUCTURE COMPONENTS AND/OR BEARER BEAMS.

IMPORTANT NOTE: =============== TILE QUANTITIES HAVE BEEN ESTIMATED USING STANDARD FORMULA'S AS RECOMENDED BY TILE MANUFACTURERS. ALTHOUGH WE MAKE EVERY EFFORT TO ENSURE THAT THE QUANTITIES ARE AS ACCURATE AS POSSIBLE, WE WILL NOT BE HELDRESPONSIBLE FOR ANY SHORTAGES SHOULD THEY ARISE. TILE COLOUR,MAKE & PROFILE TO BE CONFIRMED ON ORDER.

***Conditions***1. QUOTE SUBJECT TO PRICE INCREASES.2. UNLESS APPROVED BY C.G.I.C ACCOUNT IS HELD BY US, FULL PAYMENT WILL BE REQUIRED ON ACCEPTANCE OF THIS QUOTE.3. ROOF TRUSS DESIGN HAS BEEN DONE ACCORDING TO THE NATIONAL BUILDING REGULATIONS & DOCUMENTS RELATED THERETO, INCL. S.A.B.S 0160 'LOADING' & S.A.B.S 0163 'DESIGN OF TIMBER STRUCTURES'. ALL SPECIFICATIONS IN ACCORDANCE WITH MITEK S.A.'s MINIMUM REQUIREMENTS OF THE INSTITUTE FOR TIMBER CONSTRUCTION I.T.C.

4. WE HAVE QUOTED IN ACCORDANCE WITH INFORMATION PROVIDED ACCORDING TO DRAWINGS NO.s................5. QUANTITIES QUOTED ON ARE AS ACCURATE AS POSSIBLE ACCORDING TO THE INFORMATION PROVIDED. WE URGE YOU TO CHECK QUANTITIES PRIOR TO PLACING ORDER AS ANY ADDITIONAL MATERIAL WILL BE FOR YOUR ACCOUNT.6. ANY ADDITIONAL WORK & MATERIAL REQUIRED OUTSIDE THE SCOPE OF THE STANDARD INDUSTRY SPECIFICATION, AS PER MITEK & I.T.C. WILL BE FOR YOUR ACCOUNT.

7. THE NAILPLATES USED IN THE MANUFACTURE OF TRUSSES HAVE BEEN TESTED FOR DESIGN VALUES BY THE C.S.I.R.8. SHOULD A MITEK ENGINEER'S DESIGN BE REQUIRED, WE RESERVE THE RIGHT TO REQUOTE.9. DESIGN FEES & SITE INSPECTION BY ENGINEERS ARE ADDITIONAL TO OUR QUOTE AND WILL BE FOR YOUR ACCOUNT.

10.TRUSSES WILL BE MANUFACTURED ACCORDING TO PLAN.11.THERE CAN BE NO EXCEPTION TO THE ABOVE.12.E. + O. E.13.SITE TO BE MEASURED YES__________ NO__________14.WE RESERVE THE RIGHT TO ALTER THE DESIGN ACCORDING TO THE DESIGNER'S DISCRETION.

15.WE DO NOT CARRY OUT THE ERECTION OF ROOF TRUSSES OR THE FITTING OF ROOF TILES/SHEETING. THE PRICE QUOTED IS FOR THE MANUFACTURE AND SUPPLY ONLY.16.DELIVERY DATE OF TRUSSES WILL BE ADVISED AFTER PAYMENT HAS BEEN RECEIVED.17.NO PROVISION HAS BEEN MADE IN OUR QUOTATION TO COVER THE CHARGES MADE BY AN I.T.C INSPECTORATE, THIS WILL BE AN EXTRA TO YOUR QUOTE AND THE RELEVANT FEES CAN BE OBTAINED FROM THE I.T.C AT 011-974-1061.

18.MATERIAL FOR THE STANDARD GEYSER DETAIL HAVE NOT BEEN INCLUDED UNLESS OTHERWISE INDICATED.19.SPECIAL ARRANGEMENTS FOR TILE TRANSPORT TO SITE NEED TO BE ADVISED ON.

REPRESENTATIVE : __________________________

CUSTOMER SIGNATURE :__________________________ DATE : __________________________

The "A19" requirements:Regulation "A19" of the National Building Regulations calls for the appointment by the owner of a person responsible forthe design and inspection of the structural system. The granting of an occupancy certificate is dependant on the submissionof a loading certificate by the person appointed under regulation "A19"

Our Banking Details:

Nedbank Business Central Branch Code: 128405 Account Number: 128402 1033