ACCESSORIES 2
Air-Operated Double Diaphragm Pumps FEATURES & BENEFITS vs. Other Pump TypesAir-Operated Safe / Cool / Clean
Self Priming (Dry) Installation VersatilityLight Weight Portable
Sealless Runs DrySemi-Positive Displacement Dead Heads Safely / No Pressure Relief RequiredVariable Flow & Pressure Full Range Performance (Zero to Max GPM)
Low Internal Fluid Velocities Immeasurable Loss of Volumetric DisplacementMetallic & Non-Metallic Construction Compatible with Wide Range of Fluids
Full Range of Elastomers Compatible with Wide Range of FluidsDouble Acting / Reciprocating Low Shear & Degradation
Low NPSHR Pumps Flowable, High Viscosity FluidsAccepts “FLEXIBLE” Power Source Coupling “Plug - N - Play (PUMP)”
FEATURES & BENEFITS... SANDPIPER® Pumps vs. Other Brands“Exclusive” ESADS+Plus® (External Serviceable Air Distribution System) In - Line Serviceable“Exclusive” Cross Drilled, Pilot Operated, Directional Air Valves No - Stall Guaranteed
Lube Free Air Valves Air Line Lubricators are optionalAll Bolted Construction Safe & Easy AssemblyRotational Manifolds (Non-Metallic & Flap Valve Pumps) Horizontal or Vertical ConnectionsRotational Manifolds (Metallic Ball Valve Pumps) Horizontal, In-Line Connections
“Exclusive” CSA Certified AODD Pump Series Operates on Natural Gas - Burst Pressure to 625 PSI“Exclusive” Ex (ATEX 100a Compliant Metallic Pumps) Groundable / Spark Free
8 Non-Metallic Models (Ball Valves) Variable Flows up to 4, 14, 23, 45, 90, 150 & 238 GPM9 Metallic Models (Ball Valves) Variable Flows up to 4.4, 15, 45, 106, 150 & 235 GPM
“Exclusive” 5 Metallic Models (Flap Valves) Variable Flows up to 42, 140 & 260 GPMFull Line of Surge Suppressors Pulsation Dampening
“Exclusive” Solids Handling .03 inches to 3 inches“Exclusive” Discharge Porting Options Eliminates Entrained Air or Settled Solids
Versatile SANDPIPER® Pump designs for a wide range ofprocess control requirements
®
ACCESSORIES 3
Warren Rupp has an expanding line of Accessories & Controlsfor your total process control system.
View the typical process control system loop on the following pages
Part No. Description FitsDA05 Surge Dampener ½”PumpsDA05 Metallic Surge Dampener ½”PumpsDA07 Surge Dampener ¾”PumpsDA10 Surge Dampener 1”Pumps
Designed for use with ½”, ¾” and 1” pumps, these dampenersare manually charged with air. PTFE diaphragms are standard,with wetted parts available in Polypropylene, PVDF, and Nylon.The DA05 is also available in Aluminum and Stainless Steel.Flow and pressure fluctuations are minimized, the dampenerconsumes no air after initial charging.Hardware is 302/304 Stainless Steel.
SURGE DAMPENERS
PNEUMATICLIQUID LEVEL CONTROL
Warren Rupp’s float actuated liquid levelcontrol provide all-pneumatic operation.Especially useful in sump and liquidtransfer situations, the float actuatedswitch opens and closes air supply to thepump for positive ON-OFF response.High capacity air valve accommodates airflow requirements up to 125 cfm, witha pressure drop less than 10 psi.
2
Mechanical Leak Detector
Part No. Description Fits031-023-110 Air Operated Leak Detector ET1-M ET2-M ST1½-A031-024-110 Air Operated Leak Detector ET1½-M ET3-M ST1-A
S15 S20 & S30 ET1½-SM
When a leak chemically attacks aninternal o-ring on this detector, it actuatesa plunger. This opens an air valve, whichin turn activates a customer-suppliedsolenoid (or similar device) to triggera signal.For use with the RuppGUARD™ SpillPrevention SANDPIPER® pumps ONLY.
Part No. Description Fits032-043-000 Electronic Leak Detector ST1-A ET1-M SB1
110, 115, 220VAC ST1½-A ET1½-M SB1½032-044-000 Electronic Leak Detector SSB1 ET3-M SB2
12-32VDC SSB2 ET1½-SM SB3SET1 & SET2
032-037-000 Electronic Leak Detector S1F S20110, 115, 220VAC S15 S30
032-045-000 Electronic Leak Detector12-32VDC
If the primary pumping diaphragm fails,this modular, watertight unit sensesconductive changes if liquid enters theisolation chamber of the pump. Warninglights indicate which side of the pumpis tainted. The unit can also be wired foraudible alarm or pump shutdown. Lowvoltage. Simple installation.For use with the RuppGUARD™ SpillPrevention SANDPIPER® pumps.
Electronic Leak Detector
LEAK DETECTION1
Part No. Description FitsTA-1 Tranquilizer Surge Suppressor 1” PumpsTD-1½ Tranquilizer Surge Suppressor 1” & 1½” PumpsTA-2 Tranquilizer Surge Suppressor 1½” & 2” PumpsTA-3 Tranquilizer Surge Suppressor 3” Pumps
Metallic Surge Suppressors. For use with any reciprocatingpump, Tranquilizer surge suppressors maintain a constant aircushion volume in a pumping application for the most effectivesurge suppression. All Tranquilizer models are automaticallyself-charging and self-venting. Flexible diaphragm separatesair cushion from pumped product.
TRANQUILIZER®3
Part No. Description032.036.000. Pneumatic Liquid Level Control
A sight tube style leak detector is installedon each driver chamber. If a pumpingdiaphragm break occurs, liquid in thesight tube changes.This type of leak detection is standardconstruction on all aluminum ET and S
Non-Metallic spill prevention pumps. For use with theRuppGUARD™ Spill Prevention SANDPIPER® pumps.
Visual Leak Detector
ACCESSORIES 4
1
2
4
5
3
See page 3 for full description ofAccessories 1 thru 3.
1. Leak Detection
2. Liquid Level Control
Typical Process C
3. Tranquilizers® (Surge Dampeners)
See pages 4 & 5 for full description ofAccessories 4 thru 10.
4. Muffler Options
ACCESSORIES 5
Stroke Counter/Batch Control
WARREN RUPP PUMP CONTROLS
7
6
89 10
5. Pulse Output Kits
6. Stroke Counter/Batch Control
7. Air Line Solenoid
8. Variable Speed Control
9. Filter/Regulator
10. Air Dryer
Control Loop
ACCESSORIES 6
Part No. Description Fits475-148-036 DC Unit PB¼-A475-148-037 110/120 or 220/240VAC475-148-038 DC Intrins. Safe475-148-039 110VAC Intrins. Safe475-148-040 220VAC Intrins. Safe
475-148-001 DC Unit SE½-A SB1-A475-148-010 110/120 or 220/240VAC SA1-A ET1-M475-148-017 DC Intrins. Safe ET1½-SM ST1-A475-148-024 110VAC Intrins. Safe SB25-A SA25-A475-148-031 220VAC Intrins. Safe ST25-A
475-148-004 DC Unit for AL Valve SB1½-A SB2-A475-148-011 110/120 or 220/240VAC (AL) SA2-A SA3-A475-148-018 DC Intrins. Safe (AL) SA4-A ET1½-M475-148-025 110VAC Intrins. Safe (AL) ET2-SM ET2-M475-148-032 220VAC Intrins. Safe (AL) ST1½-A SB40-A
ST40-A
475-148-005 DC Unit for CI Valve SB1½-A SB2-A475-148-012 110/120 or 220/240VAC (CI) SA2-A SA3-A475-148-019 DC Intrins. Safe (CI) SA4-A W09475-148-026 110VAC Intrins. Safe (CI) ET1½-M ET2-SM475-148-033 220VAC Intrins. Safe (CI) ST1½-A ET2M
SB40-A ST40-A
475-148-006 DC Unit for AL Valve SA3-M SB4-A475-148-013 110/120 or 220/240VAC (AL) SA4-M ET3-S475-148-020 DC Intrins. Safe (AL) SB3-A ET3-SM475-148-027 110VAC Intrins. Safe (AL)475-148-034 220VAC Intrins. Safe (AL)
475-148-007 DC Unit for CI Valve SA3-M ET3-M475-148-014 110/120 or 220/240VAC (CI) SA4-M ET3-SM475-148-021 DC Intrins. Safe (CI) SB3-A W15475-148-028 110VAC Intrins. Safe (CI) SB4-A475-148-035 220VAC Intrins. Safe (CI)
475-198-021 DC Unit S05, S07, S10, with475-198-022 DC Intrins. Safe Encapsulated Muffler475-198-023 110/120 or 220/240VAC475-198-024 110VAC Intrins. Safe475-198-025 220VAC Intrins. Safe
475-198-026 DC Unit S05, S07, S10, with475-198-027 DC Intrins. Safe Muffler, Mesh Muffler475-198-028 110/120 or 220/240VAC or Direct-Piped Exhaust475-198-029 110VAC Intrins. Safe475-198-030 220VAC Intrins. Safe
475-198-001 DC Unit S1F Non-Metallic (DL3)475-198-002 DC Intrins. Safe S1F, S15, S20, S30, with475-198-003 110/120 or 220/240VAC Muffler, Mesh Muffler475-198-004 110VAC Intrins. Safe or Direct-Piped Exhaust475-198-005 220VAC Intrins. Safe
475-198-006 DC Unit S1F Non-Metallic (DL3)475-198-007 DC Intrins. Safe S1F, S15, S20, S30, with475-198-008 110/120 or 220/240VAC Encapsulated Muffler475-198-009 110VAC Intrins. Safe475-198-010 220VAC Intrins. Safe
Offered in a wide variety ofsizes and voltages. These controlsinterface with the Warren RuppBatch Controller, or your ownprocess controls (PLC’s). Availablein kit form, for field installation,or factory-built into a new pump.
PULSE OUTPUTINTERFACE KITS5
Part No. Description Fits894-001-000 110/120VAC Unit PB¼-A S07894-002-000 220/240VAC Unit S05 S10894-003-000 12VDC Unit894-004-000 24VDC Unit
894-005-000 110/120VAC Unit SA1-A ET1-M ST1-A894-006-000 220/240VAC Unit SA25-A ET1½-SM ST25-A894-007-000 12VDC Unit SB1-A SE½-A894-008-000 24VDC Unit SB25-A S1F
894-009-000 110/120VAC Unit SA2-A SB1½-A ET1½-M ST40-A894-010-000 220/240VAC Unit SA3-A SB2-A ET2-M ST3-M894-011-000 12VDC Unit SA4-A SB3-A ET2-SM W09894-012-000 24VDC Unit SA3-M SB4-A ET3-SM W15
SA4-M S15 S20 S30
Provides automatic on/off operation of air-driven equipment.110/120VAC and 220/240VAC (50/60 hertz) kits operate withthe Warren Rupp or customer’s control units. 12VDC and 24VDCkits operate with customer-supplied controls only.
AIR LINE SOLENOID KIT7
Transforms your diaphragm pump into an accurate, controllablepump system. Uses interfaceable, user-friendly componentsfor existing or new pumps, and process control systems. Iteliminates troublesome and expensive flow-sensing devices.The Stroke Counter/Batch Control is an interfaceable electroniccontrol to program repetitive diaphragm pump operations. Thisindustrial-grade control offers performance and repeatability.Compatible with all Warren Rupp air-operated diaphragmpumps. The control unit functions as a batch control, a strokecounter, or both.The complete system requires the Stroke Counter/BatchController, the Pulse Output Kit & the Air line Solenoid.
Part No. Description Voltage249-006-000 110/120 or 220/240 VAC 110v, 220v
Single phase 50/60 Hz
STROKE COUNTER/BATCH CONTROL6
Part No. Description Fits530-007-000 Muffler, Brass Mesh ½” air outlet530-008-000 Muffler, Brass Mesh ¾” air outlet530-010-000 Muffler, Brass Mesh 1” air outlet530-018-000 Muffler, Brass Mesh ¾” air outlet530-023-000 Muffler, Brass Mesh 3/8” air outlet
530-024-000 Muffler, Sound Dampening 3/8” air outlet530-025-000 Muffler, Sound Dampening ½” air outlet530-026-000 Muffler, Sound Dampening ¾” air outlet530-027-000 Muffler, Sound Dampening 1” air outlet530-034-000 Muffler, Sound Dampening ¾” air outlet
530-033-000 Muffler, Metallic 1” air outlet530-035-000 Muffler, Metallic 3/8” air outlet530-036-000 Muffler, Metallic ¾” air outlet
OPTIONALMUFFLERS
Effective sound dampening for Warren Rupp pumps. Mufflersare a rugged Polymer or metallic housing. Sound dampeningand encapsulated mufflers have replaceable acoustic compositeinserts. All Warren Rupp pumps are supplied with a basic muffler.
4
ACCESSORIES 7
®SANDPIPER, PortaPump, Tranquilizer, and Warren Rupp are registered tradenames of Warren Rupp, Inc.©Copyright 2004 Warren Rupp, Inc. All rights reserved.
Pail & DrumAdaptor Kits
Converting ¼”, ½” and ¾” plastic pumps for drum or pailapplications is easy. The adaptor kits are constructed ofchemically-resistant materials to handle the job. Plastic pipeassembly comes complete with all the hardware needed. Simplyattach the threaded end to the suction manifold and lower itinto the liquid source.
Part No. Description Material Fits031-091-520 55 gallon Drum Kit PVDF ¼”& ½” Pumps031-091-555 55 gallon Drum Kit PVC ¼”& ½” Pumps
475-161-520 120# Barrel Kit PVDF ½” Pumps475-161-555 120# Barrel Kit PVC ½” Pumps475-196-520 120# Barrel Kit PVDF ½” Pumps475-196-552 120# Barrel Kit PVC ½” Pumps
475-149-520 Pail Adaptor Kit PVDF ¼” Pumps475-149-552 Pail Adaptor Kit Polypropylene ¼” Pumps475-150-520 Pail Adaptor Kit PVDF ½” Pumps475-150-552 Pail Adaptor Kit Polypropylene ½” Pumps475-151-520 Pail Adaptor Kit PVDF ¾” Pumps475-151-552 Pail Adaptor Kit Polypropylene ¾” Pumps
475-194-520 Pail Adaptor Kit PVDF ½” Pumps475-194-552 Pail Adaptor Kit Polypropylene ½” Pumps
475-195-520 Pail Adaptor Kit PVDF ¾” Pumps475-195-552 Pail Adaptor Kit Polypropylene ¾” Pumps
For additional information, please consult the factory or individual datasheets on our website: www.warrenrupp.com
Part No. Description020-046-007 ¼” Air Dryer020-047-007 ½” Air Dryer020-048-008 1” Air Dryer
This point-of-use air dryer is designed to remove 99% of thewater, rust and other contaminants commonly present incompressed air lines. Clean, dry air enhances the life andperformance of pneumatically-driven equipment.
AIR DRYER10
Part No. Description020-049-000 ¼” Filter Regulator*020-049-001 ¼” Lubricator020-049-002 ¼” Shut Off Valve020-049-004 20 Micron Filter Element020-049-005 Regulator Repair Kit020-049-006 Lubricator Repair Kit020-049-007 Mounting Bracket020-049-008 End Plate Kit020-050-000 ½” Filter Regulator*020-050-001 ½” Lubricator020-050-002 ½” Shut Off Valve020-050-004 40 Micron Filter Element020-050-005 Regulator Repair Kit020-050-007 Mounting Bracket020-050-008 End Plate Kit020-051-000 ¾” Filter Regulator**020-051-001 ¾” Lubricator
Clean, dry air is the key to trouble-free pump operation. TheWarren Rupp Filter/Regulator line offers modular conveniencefor installation and service.
*includes mounting bracket and 1½” pressure gauge**includes mounting bracket and 2” pressure gauge
FILTER/REGULATOR9
ELECTRONIC SPEED CONTROL
Part No. Description Voltage032-022-000 Electronic Speed Control 110v032-023-000 Electronic Speed Control 220v
Easy installation and operation. Fits most air-operated diaphragmpumps with operating pressures to 125 psi. Accurate control ofvariable flow rates, from zero flow to maximum. Operates on110 or 220VAC. Manual operation with on-board, single turnpotentiometer or automatic mode for remote control using theoptional 4-20 mA input terminal. Speed Control System can beintegrated with existing process control systems.
8
REGISTERED QUALITY SYST
EM®
Quality SystemCertified
®
REGISTERED
ENVIR
ONM
ENTAL MANAGEMENTSY
STEM
Environmental ManagementSystem Certified
WARREN RUPP, INC.A Unit of IDEX Corporation
800 North Main StreetP.O. Box 1568
Mansfield, OH 44901-1568 USAPhone: 419-524-8388
Fax: 419-522-7867
ACC 604
Recommended