View
222
Download
2
Category
Preview:
Citation preview
ANNEXURE 'D'
In Figures In Words
1 1.1 Carriage of materials
1.11.1.2 Lead 15 Km earth
Cum 99.46
2
2.8
Earth work in excavation by mechanical means (Hydraulic
excavator) / manual means in foundation trenches or drains (not
exceeding 1.5 m in width or 10 sqm on plan), including dressing of
sides and ramming of bottoms, lift upto 1.5 m, including getting out
the excavated soil and disposal of surplus excavated soil as directed,
within a lead of 50 m.
2.12.8.1 All kinds of soil
Cum 122.5
32.1
Excavating trenches of required width
for pipes, cables etc3.1 2.10.1 All kinds of soil
3.1.12.10.1.2
Pipes cables tec. Exceeding 80mm dia
but not exceeding 300mm dia Mtr 200
4
2.27Supplying and filling in plinth with river sand under floors,
including watering, ramming consolidating and dressing complete.Cum 10
5
2.31
Clearing jungle including uprooting of rank vegetation, grass, brush
wood, trees and saplings of girth up to 30 cm measured at a height
of 1 m above ground level and removal of rubbish up to a distance
of 50 m outside the periphery of the area cleared.Sqm 34740
6
2.33
Felling trees of the girth (measured at a height of 1 m above ground
level) including cutting of trunks and branches, removing the roots
and stacking of serviceable material and disposal of unserviceable
material.
6.1.12.33.2 Beyond 60 cm girth up to and including 120 cm girth
Each 25
ANNUAL REPAIR AND MAINTENANCE OF (CIVIL AND ELECTRICAL) WORKS, SUPPLY OF DIESEL TO 2000 KVA DG SET OF ESI HOSPITAL &
STAFF QUARTERS AT VARADARAJAPURAM, COIMBATORE AND DISPENSARIES AND STAFF QUARTERS AT SOWRIPALAYAM, UPPILIPALAYAM
AND VELLALORE FOR THE YEAR 2017-18FINANCIAL BID
Item
No
DSR Item
No.Description Qty Units
RateTotal
Page 1 of 40
In Figures In Words
Item
No
DSR Item
No.Description Qty Units
RateTotal
7
2.35
Diluting and injecting chemical emulsion for
POSTCONSTRUCTIONAL
anti-termite treatment (excluding the cost of chemical emulsion)
7.1.1
2.35.5
Treatment at points of contact of wood work by chemical
emulsion Chlorpyriphos/ Lindane (in oil or kerosene based
solution) @ 0.5 litres per hole by drilling 6 mm dia holes at
downward angle of 45 degree at 150 mm centre to centre and
sealing the same. Mtr 60
8
4.1
Providing and laying in position cement concrete of specified grade
excluding the cost of centering and shuttering - All work up to
plinth level:
8.14.1.3
1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm
nominal size) Cum 6.885
94.1.8
1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm
nominal size) Cum 10
9.1 4.1.8 For Plinth protection
10
4.5
Providing and fixing up to floor five level precast cement concrete
string or lacing courses, copings, bed plates, anchor blocks, plain
window sills, shelves, louvers, steps, stair cases, etc. including
hoisting and setting in position with cement mortar
10.14.5.1
1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm
nominal size) Cum 1.8
11
5.1
Providing and laying in position specified grade of reinforced
cement concrete, excluding the cost of centering, shuttering,
finishing and reinforcement - All work up to plinth level :
11.15.1.3
1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm
nominal size) Cum 6.13
125.9
Centering and shuttering including strutting, propping etc. and
removal of form for :
12.15.9.3 Suspended floors, roofs, landings, balconies and access platform
Sqm 20
13
5.9.15
Small lintels not exceeding 1.5 m clear span, moulding as in
cornices, window sills, string courses, bands, copings, bed plates,
anchor blocks and the like Sqm 10
Page 2 of 40
In Figures In Words
Item
No
DSR Item
No.Description Qty Units
RateTotal
13.1 5.9.15 Hospital and Dispensaries
13.15.9.19 Weather shade, Chajjas, corbels etc., including edges
Sqm 10
14
5.22
Steel reinforcement for R.C.C. work including straightening,
cutting, bending, placing in position and binding all complete upto
plinth level
14.15.22.6 Thermo-Mechanically Treated bars
Kgs 490.4
15
6.1Brick work with common burnt clay F.P.S. (non modular) bricks of
class designation 7.5 in foundation and plinth in :
15.16.1.2 Cement mortar 1:6 (1 cement : 6 coarse sand)
Cum 20
16
6.4
Brick work with common burnt clay F.P.S. (non modular) bricks of
class designation 7.5 in superstructure above plinth level up to floor
V level in all shapes and sizes in :
16.16.4.2 Cement mortar 1:6 (1 cement : 6 coarse sand)
Cum 30
17
6.12Half brick masonry with common burnt clay F.P.S (non modular
bricks) of class designation 7.5 in foundation and plinth
17.16.12.2 Cement mortor 1:4 (1 cement: 4 coarse sand)
Sqm 30
18
6.13
Half brick masonry with common burnt clay F.P.S. (non modular)
bricks of class designation 7.5 in superstructure above plinth level
up to floor V level.
18.16.13.2 Cement mortar 1:4 (1 cement :4 coarse sand)
Sqm 30
19
8.2
Providing and fixing 18 mm thick gang saw cut, mirror polished,
premoulded and prepolished, machine cut for kitchen platforms,
vanity counters, window sills, facias and similar locations, of
required size, approved shade, colour and texture laid over 20 m
Page 3 of 40
In Figures In Words
Item
No
DSR Item
No.Description Qty Units
RateTotal
19.18.2.1
Raj Nagar Plain white marble / Udaipur green marble / Zebra black
marble
19.1.18.2.1.2 Area of slab over 0.50 sqm
Sqm 20
20 8.2.2 Granite of any colour and shade
20.18.2.2.2 Area of slab over 0.50 sqm
Sqm 10
21
9.1
Providing wood work in frames of doors, windows, clerestory
windows and other frames, wrought framed and fixed in position
with hold fast lugs or with dash fasteners of required dia & length (
hold fast lugs or dash fastener shall be paid for separately).
21.19.1.2 Sal wood
Cum 0.1
22
9.5
Providing and fixing panelled or panelled and glazed shutters for
doors, windows and clerestory windows, including ISI marked
M.S.pressed butt hinges bright finished of required size with
necessery screws, excluding panelling which will be paid for separa
22.1 9.5.1 Second class teak wood
9.5.1.1 35 mm thick shuttersSqm 4
23
9.18
Providing and fixing Pre-laminated flat pressed 3 layer (medium
density) particle board or graded wood particle board IS : 3087
marked, with one side decorative and other side balancing
lamination Grade I, Type II exterior grade IS : 12823 marked, in
shel
23.19.18.2 25 mm thick
Sqm 2
24
9.20
Providing and fixing ISI marked flush door shutters conforming to
IS : 2202 (Part I) decorative type, core of block board construction
with frame of 1 st class hard wood and well matched teak 3 ply
veneering with vertical grains or cross bands and face ve
Page 4 of 40
In Figures In Words
Item
No
DSR Item
No.Description Qty Units
RateTotal
24.19.20.2
30 mm thick including ISI marked Stainless Steel butt hinges with
necessary screws Sqm 21
25
9.46
Providing and fixing curtain rods of 1.25 mm thick chromium
plated brass plate, with two chromium plated brass brackets fixed
with C.P. brass screws and wooden plugs, etc., wherever necessary
complete:
25.19.46.2 20 mm dia
Mtr 10
26
9.48
Providing and fixing M.S. grills of required pattern in frames of
windows etc. with M.S. flats, square or round bars etc. including
priming coat with approved steel primer all complete.
26.19.48.2 Fixed to openings/ wooden frames with rawl plugs screws etc
Kgs 750
27
9.83
Providing and fixing aluminium die cast body tubular type
universal hydraulic door closer (having brand logo with ISI, IS :
3564, embossed on the body, door weight upto 35 kg and door
width upto 700 mm), with necessary accessories and screws etc.
complet Each 5
28
9.95
Providing and fixing ISI marked aluminium butt hinges anodised
(anodic coating not less than grade AC 10 as per IS : 1868)
transparent or dyed to required colour or shade with necessary
screws etc. complete :
28.19.95.1 125x75x4 mm
Each 40
28.1.19.95.3 100x63x4 mm
Each 40
28.1.29.95.6 75x63x4 mm
Each 40
29
9.96
Providing and fixing aluminium sliding door bolts, ISI marked,
anodised (anodic coating not less than grade AC 10 as per IS : 1868),
transparent or dyed to required colour or shade, with nuts and
screws etc. complete:
Page 5 of 40
In Figures In Words
Item
No
DSR Item
No.Description Qty Units
RateTotal
29.19.96.1 300x16 mm
Each 40
29.1.19.96.2 250x16 mm
Each 40
30
9.97
Providing and fixing aluminium tower bolts, ISI marked, anodised
(anodic coating not less than grade AC 10 as per IS : 1868 ),
transparent or dyed to required colour or shade, with necessary
screws etc. complete:
30.19.97.2 250x10 mm
Each 40
30.1.19.97.4 150x10 mm
Each 40
30.1.29.97.5 100x10 mm
Each 40
31
9.100
Providing and fixing aluminium handles, ISI marked, anodised
(anodic coating not less than grade AC 10 as per IS : 1868)
transparent or dyed to required colour or shade, with necessary
screws etc. complete:
31.19.100.2 100 mm
Each 40
31.1.19.100.3 75 mm
Each 40
32
9.101
Providing and fixing aluminium hanging floor door stopper, ISI
marked, anodised (anodic coating not less than grade AC 10 as per
IS : 1868) transparent or dyed to required colour and shade, with
necessary screws etc. complete.
32.19.101.1 Single rubber stopper
Each 40
32.1.19.101.2 Twin rubber stopper
Each 10
Page 6 of 40
In Figures In Words
Item
No
DSR Item
No.Description Qty Units
RateTotal
33
9.113
Providing and fixing bright finished 100 mm mortice lock with 6
levers without pair of handles of approved quality for aluminium
door, with necessary screws etc complete as per direction of
Engineer-in-charge. Each 2
34
9.117
Providing and fixing factory made uPVC door frame made of uPVC
extruded sections having an overall dimension as below (tolerance
±1mm), with wall thickness 2.0 mm (± 0.2 mm), corners of the door
frame to be Jointed with galvanized brackets and stainless steel
screws, joints mitred and plastic welded. The hinge side vertical of
the frames reinforced by galvanized M.S. tube of size 19 X 19 mm
and 1 mm (± 0.1 mm) wall thickness and 3 nos. stainless steel hinges
fixed to the frame complete as per manufacturer's specification and
direction of Engineer-in-charge
34.19.117.2 Extruded section profile size 42x50 mm
RM 260.1
35
9.120
Providing and fixing factory made panel PVC door shutter
consisting of frame made out of M.S. tubes of 19 gauge thickness
and size of 19 mm x 19 mm for styles and 15x15 mm for top &
bottom rails. M.S. frame shall have a coat of steel primers of
approved make and manufacture . M.S. frame covered with 5 mm
thick heat moulded PVC 'C' channel of size 30 mm thickness, 70
mm width out of which 50 mm shall be flat and 20 mm shall be
tapered in 45 degree angle on both side forming styles and 5 mm
thick, 95 mm wide PVC sheet out of which 75 mm shall be flat and
20 mm shall be tapered in 45 degree on the inner side to form top
and bottom rail and 115 mm wide PVC sheet out of which 75 mm
shall be flat and 20 mm shall be tapered on both sides to form lock
rail. Top, bottom and lock rails shall be provided both side of the
panel. 10 mm (5 mm x 2 ) thick, 20 mm wide cross PVC sheet be
provided as gap insert for top rail & bottom rail. paneling of 5 mm
thick both side PVC sheet to be fitted in the M.S. frame welded/
sealed to the styles & rails with 7 mm (5 mm+2 mm) thick x 15 mm
wide PVC sheet beading on inner side, and joined together with
solvent cement adhesive. An additional 5 mm thick PVC strip of 20
Page 7 of 40
In Figures In Words
Item
No
DSR Item
No.Description Qty Units
RateTotal
35.1 9.120.1 30 mm thick plain PVC door shutters Sqm 81.6
36
9.128
Providing and fixing factory made Fiberglass Reinforced plastics
(F.R.P.)
chajja 4 mm thick of required colour, size and design made by Resin
Transfer Moulding (RTM) Machine Technology, resulting in void
free
compact laminate in single piece, having smooth gradual slope
curvature for easy drainage of water and duly reinforced by 2nos
vertically and 1nos horizontally 50x2 mm thick M.S. flat with 12
mm in built hole for grouting on the existing wall along with the 50
mm flanges duly inserted and sealed in the wall complete in one
single piece casted onolithically, including all necessary fittings .
The FRP Chajja should be manufactured using unsaturated
Polyester resin as per IS: 6746, duly reinforced with fibre glass
chopped strand mat (CSM) as per IS: 11551 complete with
protective Gel coat U/V coating on Top for complete resistance
from the extreme of temperature, weather & sunlight
Sqm 10
37
10.25
Steel work welded in built up sections / framed work, including
cutting, hoisting, fixing in position and applying a priming coat of
approved steel primer using structural steel etc. as required.
37.110.25.2
In gratings, frames, guard bar, ladder, railings, brackets, gates and
similar works Kgs 789.6
38
11.2
Chequerred precast cement concrete tiles 22mm thick in footpath &
out yard jointed with neat cement slurry mixed with pigment to
match the shade of tiles including rubbing and cleaning etc.
complete on 20mm thick bed of cement mortar 1:4 (1 cement : 4
coarse sand)
38.111.20.3 Dark shade using ordinary cement
Sqm 10
Page 8 of 40
In Figures In Words
Item
No
DSR Item
No.Description Qty Units
RateTotal
39
11.26
Kota stone slab flooring over 20 mm (average) thick base laid over
and jointed with grey cement slurry mixed with pigment to match
the shade of the slab, including rubbing and polishing complete
with base of cement mortar 1 : 4 (1 cement : 4 coarse sand)
39.1 11.26.1 25 mm thick Sqm 20
40
11.27
Kota stone slabs 20 mm thick in risers of steps, skirting, dado and
pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement:
3
coarse sand) and jointed with grey cement slurry mixed with
pigment to
match the shade of the slabs, including rubbing and polishing
complete. Sqm 20
41
11.36
Providing and fixing 1st quality ceramic glazed wall tiles
conforming to IS : 15622 (thickness to be specified by the
manufacturer), of approved make, in all colours, shades except
burgundy, bottle green, black of any size as approved by Engineer-
in-Charg Sqm 300
42
11.37
Providing and laying Ceramic glazed floor tiles of size 300x300 mm
(thickness to be specified by the manufacturer), of 1st quality
conforming to IS : 15622, of approved make, in colours such as
White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cemenSqm 200
4311.41.2 Vitrified tiles laid and pasted over existing floor tiles
Sqm 250
44
12.41
Providing and fixing on wall face unplasticised Rigid PVC rain
water pipes conforming to IS : 13592 Type A, including jointing
with seal ring conforming to IS : 5382, leaving 10 mm gap for
thermal expansion, (i) Single socketed pipes.
44.112.41.1 75 mm diameter
RM 50
44.1.112.41.2 110 mm diameter
RM 175
Page 9 of 40
In Figures In Words
Item
No
DSR Item
No.Description Qty Units
RateTotal
45
12.42
Providing and fixing on wall face unplasticised-PVC moulded
fittings / accessories for unplasticised Rigid PVC rain water pipes
conforming to IS : 13592 Type A, including jointing with seal ring
conforming to IS : 5382, leaving 10 mm gap for thermal expansion.
45.112.42.1.2 Coupler 110 mm dia
Each 40
45.1.112.42.3.2 Single tee with door - 110x110x110 mm
Each 40
45.1.212.42.5.2 Bend 87.5° - 110 mm bend
Each 40
45.1.312.42.6.2 Shoe (Plain) 110 mm Shoe
Each 40
46
12.43
Providing and fixing unplasticised-PVC pipe clips of approved
design to unplasticised-PVC rain water pipes by means of 50x50x50
mm hard wood plugs, screwed with M.S. screws of required length,
including cutting brick work and fixing in cement mortar 1:4 (1
cement : 4 coarse sand) and making good the wall etc. complete.
46.112.43.2 110 mm
Each 200
4813.5
15 mm cement plaster on rough side of single or half brick wall of
mix:
48.113.5.1 1:4 (1 cement : 4 coarse sand)
Sqm 100
49
13.26
Providing and applying plaster of paris putty of 2 mm thickness
over plastered surface to prepare the surface even and smooth
complete. Sqm 600
5014.66
Finishing walls with Acrylic Smooth exterior paint of required
shade:
50.114.66.1
Old work (Two or more coats applied @ 1.67 ltr/ 10 sqm) on
existing cement paint surface Sqm 24496
5113.60
Wall painting with plasters emulsion paint of approved brand and
manufacturer to gve an even shade.
Page 10 of 40
In Figures In Words
Item
No
DSR Item
No.Description Qty Units
RateTotal
51.113.60.1 one or more coats on old work
Sqm 17359.7
52
14.1
Repairs to plaster of thickness 12 mm to 20 mm in patches of area
2.5 sq meters and under, including cutting the patch in proper
shape, raking out joints and preparing and plastering the surface of
the walls complete, including disposal of rubbish to the
52.114.1.1 With cement mortar 1:4 (1 cement : 4 fine sand)
Sqm 150
5314.6 Renewing glass panes, with wooden fillets wherever necessary :
53.114.6.1 Float glass panes of thickness 4 mm
Sqm 20
54
14.12
Providing and fixing 16 mm M.S. Fan clamps of standard shape and
size in existing R.C.C. slab, including cutting chase, anchoring
clamp to reinforcement bar, including cleaning, refilling, making
good the chase with matching concrete, plastering and paintEach 4
55 14.42 White washing with lime to give an even shade:
55.114.42.2 old work ( two or more coats)
Sqm 10
56
14.46
Removing dry or oil bound distemper, water proofing cement paint
and the like by scrapping, sand papering and preparing the surface
smooth including necessary repairs to scratches etc. complete.Sqm 15000
5714.45
Distempering with oil bound washable distemper of approved
brand and manufacture to give an even shade:
57.114.45.1 Old work (one or more coats)
Sqm 17420.5
5814.54
Painting with synthetic enamel paint of approved brand and
manufacture of required colour to give an even shade:
58.114.54.1 One or more coats on old work
Sqm 5414
5913.63
Painting with aluminium paint of approved brand and manufacture
to give an even shade
Page 11 of 40
In Figures In Words
Item
No
DSR Item
No.Description Qty Units
RateTotal
59.113.63.1 Two or more coats on new work
Sqm 20
60
14.72
Providing and fixing double scaffolding system (cup lock type) on
the exterior side, up to seven story height made with 40 mm dia
M.S. tube 1.5 m centre to centre, horizontal & vertical tubes joining
with cup & lock system with M.S. tubes, M.S. tube challies, M.S.
clamps and M.S. staircase system in the scaffolding for working
platform etc. and maintaining it in a serviceable condition for the
required duration as approved and removing it there after .The
scaffolding system shall be stiffened with bracings, runners,
connection with the building etc wherever required for inspection
of work at required locations with essential safety features for the
workmen etc. complete as per directions and approval of
Engineerin- charge .The elevational area of the scaffolding shall be
measured for payment purpose .The payment will be made once
irrespective
of duration of scaffolding
Sqm 50
61
15.3
Demolishing R.C.C. work manually / by mechanical means
including stacking of steel bars and disposal of unserviceable
material within 50 metres lead as per direction of Engineer-in-
Charge. (as per qty 5.1.3) Cum 2
62
15.60
Disposal of building rubbish / malba / similar unserviceable,
dismantled or waste materials by mechanical means, including
loading, transporting, unloading to approved municipal dumping
ground or as approved by Engineer-in-charge, beyond 50 m initial
lead Cum 215.29
63
15.7
Demolishing brick work manually / by mechanical means including
stacking of serviceable material and disposal of unserviceable
material within 50 metres lead as per direction of Engineer-in-
Charge. 63.1 15.7.4 In cement mortar Cum 2
64
15.13Taking out doors, windows and clerestory window shutters (steel or
wood) including stacking within 50 metres lead:
Page 12 of 40
In Figures In Words
Item
No
DSR Item
No.Description Qty Units
RateTotal
64.115.13.1 Of area 3 sq. metres and below
Sqm 20
6515.23
Dismantling tile work in floors and roofs laid in cement mortar
including stacking material within 50 metres lead.
65.115.23.2 For thickness of tiles above 25 mm and up to 40 mm
Sqm 900
66
17.1
Providing and fixing water closet squatting pan (Indian type W.C.
pan) with 100 mm Sand Cast Iron P or S trap, 10 litre low level
white P.V.C. flushing cistern, including flush pipe, manually
controlled device (handle lever) conforming to IS : 7231, with
66.117.1.1
White Vitreous china Orissa pattern W.C. pan of size 580x440 mm
with integral type foot rests Each 40
67
17.2
Providing and fixing white vitreous china pedestal type water closet
(European type W.C. pan) with seat and lid, 10 litre low level white
P.V.C. flushing cistern, including flush pipe, with manually
controlled device (handle lever), conforming to IS : 723
67.117.2.1 W.C. pan with ISI marked white solid plastic seat and lid
Each 30
68
17.23
Providing and fixing white vitrus china flat back or wall corner type
lipped front urinal basin of 430 x 260x 350 mm or 340 x 410 x 265
mm sizes respectively Each 20
6917.24
Providing and fixing white vitreous china squatting plate urinal
with integral rim longitudinal flush pipe. Each 5
70
17.7
Providing and fixing wash basin with C.I. brackets, 15 mm C.P.
brass pillar taps,32 mm C.P. brass waste of standard pattern,
including painting of fittings and brackets, cutting and making
good the walls wherever require:
70.117.7.1
White Vitreous China Wash basin size 630x450 mm with a pair of
15 mm C. P. brass pillar taps Each 50
71
17.10
Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as
per IS 13983 with C.I. brackets and stainless steel plug 40 mm,
including painting of fittings and brackets, cutting and making
good the walls wherever required:
Page 13 of 40
In Figures In Words
Item
No
DSR Item
No.Description Qty Units
RateTotal
71.1 17.10.2 Kitchen sink without drain board
71.1.117.10.2.1 610x510 mm bowl depth 200 mm (without drain board)
Each 45
7217.28
Providing and fixing P.V.C. waste pipe for sink or wash basin
including PVC. waste fittings complete. 72.1 17.28.2 Flexible pipe
72.1.117.28.2.1 Flexible pipe - 32 mm dia
Each 50
73
17.31
Providing and fixing 600x450 mm beveled edge mirror of superior
glass (of approved quality) complete with 6 mm thick hard board
ground fixed to wooden cleats with C.P. brass screws and washers
complete. Each 30
7417.70 Providing and fixing PTMT Bottle Trap for Wash basin and sink.
74.1
17.70.2
Bottle trap 38 mm single piece moulded with height of 270 mm,
effective length of tail pipe 260 mm from the centre of the waste
coupling, 77 mm breadth with 25 mm minimum water seal,
weighing not less than 263 gms Each 40
75
18.7
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,
having thermal stability for hot & cold water supply, including all
CPVC plain & brass threaded fittings including fixing the pipe with
clamps at 1.00 m spacing. This includes jointing of p
75.1.118.7.2 20mm nominal outer dia pipes
Mtr 350
75.1.218.7.3 25 mm nominal outer dia pipes
Mtr 200
75.1.318.7.5 40 mm nominal outer dia Pipes
Mtr 200
75.1.418.7.6 50 mm nominal outer dia Pipes
Mtr 200
Page 14 of 40
In Figures In Words
Item
No
DSR Item
No.Description Qty Units
RateTotal
76
18.9
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,
having thermal stability for hot & cold water supply including all
CPVC plain & brass threaded fittings This includes jointing of pipes
& fittings with one step CPVC solvent cement ,trenching ,refilling
& testing of joints complete as per direction of Engineer in Charge.
76.118.9.7 62.50 mm nominal outer dia Pipes
Mtr 40
76.1.118.9.8 75 mm nominal outer dia Pipes
Mtr 60
77
18.8
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,
having thermal stability for hot & cold water supply, including all
CPVC plain & brass threaded fittings i/c fixing the pipe with clamps
at 1.00 m spacing. This includes jointing of pipes &
77.1
18.8.2 20 mm nominal outer dia pipes
Mtr 200
78
18.10
Providing and fixing G.I. pipes complete with G.I. fittings and
clamps, including cutting and making good the walls etc.
Internal work - Exposed on wall
78.1
18.10.3 25 mm dia nominal bore
Mtr 10
78.1.1
18.10.4 32 mm dia nominal bore
Mtr 10
78.1.2
18.10.5 40 mm dia nominal bore
Mtr 10
78.1.3
18.10.6 50 mm dia nominal bore
Mtr 10
Page 15 of 40
In Figures In Words
Item
No
DSR Item
No.Description Qty Units
RateTotal
79
18.12
Providing and fixing G.I. pipes complete with G.I. fittings including
trenching and refilling etc.
External work
79.1
18.12.3 25 mm dia nominal bore
Mtr 20
79.1.2
18.12.4 32 mm dia nominal bore
Mtr 20
79.1.3
18.12.5 40 mm dia nominal bore
Mtr 20
79.1.4
18.12.6 50 mm dia nominal bore
Mtr 20
79.1.5
18.12.7 65 mm dia nominal bore
Mtr 20
79.1.6
18.12.8 80 mm dia nominal bore
Mtr 20
8018.18
Providing and fixing ball valve (brass) of approved quality, High or
low pressure, with plastic floats complete:
80.1
18.18.3 25 mm nominal bore
Each 100
81
18.47
Providing and fixing G.I. Union in existing G.I. pipe line, cutting
and threading the pipe and making long screws, including
excavation, refilling the earth or cutting of wall and making good
the same complete wherever required:
81.1
18.47.3 25 mm nominal bore
Each 10
81.1.1
18.47.4 32 mm nominal bore
Each 10
Page 16 of 40
In Figures In Words
Item
No
DSR Item
No.Description Qty Units
RateTotal
81.1.2
18.47.5 40 mm nominal bore
Each 10
81.1.3
18.47.6 50 mm nominal bore
Each 10
81.1.4
18.47.7 65 mm nominal bore
Each 10
81.1.5
18.47.8 80 mm nominal bore
Each 5
83
19.1
Providing, laying and jointing glazed stoneware pipes class SP-1
with stiff mixture of cement mortar in the proportion of 1:1 (1
cement : 1 fine sand) including testing of joints etc. complete:
83.1
19.1.1 100 mm diameter
Mtr 200
83.1.1
19.1.3 200 mm diameter
Mtr 50
84
19.2
Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse
sand : 10 graded stone aggregate 40 mm nominal size) all-round
S.W. pipes including bed concrete as per standard design:
84.1
19.2.1 100 mm diameter S.W. pipe
Mtr 40
84.1.1
19.2.3 200 mm diameter S.W.Pipes
Mtr 50
85
19.5
Dismantling of old S.W. pipes including breaking of joints and bed
concrete stacking of useful materials near the site within 50 m lead
and disposal of unserviceable materials into municipal dumps:
Page 17 of 40
In Figures In Words
Item
No
DSR Item
No.Description Qty Units
RateTotal
85.119.5.1 100 mm diameter
Mtr 200
85.1.119.5.3 200 mm diameter 19.1.3
Mtr 50
86
19.7
Constructing brick masonry manhole in cement mortar 1:4 ( 1
cement : 4
coarse sand ) with R.C.C. top slab with 1:2:4 mix (1 cement : 2
coarse
sand : 4 graded stone aggregate 20 mm nominal size), foundation
concrete
1:4:8 mix (1 cement : 4 coarse sand : 8 graded stone aggregate 40
mm
nominal size), inside plastering 12 mm thick with cement mortar
1:3 (1
cement : 3 coarse sand) finished with floating coat of neat cement
and
making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand :
4 graded stone aggregate 20 mm nominal size) finished with a
floating coat
of neat cement complete as per standard design
86.1
19.7.2
Inside size 120x90 cm and 90 cm deep including C.I. cover with
frame (heavy duty) 500 mm internal diameter, total weight of
cover and frame to be not less than 116 kg (weight of cover 58
kg and weight of frame 58 kg) :
86.1.119.7.2.1 With FPS bricks class designation 7.5.
Each 9
88 19.8 Extra for depth for manholes
88.1 19.8.2 Size 120x80 cm
88.1.119.8.2.1
With common burnt clay F.P.S. (non modular) bricks of class
designation 7.5 RM 3
Page 18 of 40
In Figures In Words
Item
No
DSR Item
No.Description Qty Units
RateTotal
89
21.1
Providing and fixing aluminium work for doors, windows,
ventilators and partitions with extruded built up standard tubular
sections/ appropriate Z sections and other sections of approved
make conforming to IS: 733 and IS: 1285, fixing with dash fasteners
89.1 21.1.1 For fixed portion
89.1.2
21.1.1.1
Anodised aluminium (anodised transparent or dyed to required
shade according to IS: 1868, Minimum anodic coating of grade AC
15) Kgs 105
90
21.1.2
For shutters of doors, windows & ventilators including providing
and fixing hinges / pivots and making provision for fixing of fittings
wherever required including the cost of EPDM rubber / neoprene
gasket required (Fittings shall be paid for separately).
90.1
21.1.2.1
Anodised aluminium (anodised transparent or dyed to required
shade according to IS: 1868, Minimum anodic coating of grade AC
15) Kgs 90
91
21.2
Providing and fixing 12 mm thick prelaminated particle board flat
pressed three layer or graded wood particle board conforming to IS:
12823 Grade I Type II, in panelling fixed in aluminum doors,
windows shutters and partition frames with C.P. brass / stainless
steel screws etc. complete as per architectural drawings and
directions of Engineer-in-Charge.
91.121.2.1
Pre-laminated particle board with decorative lamination on one
side and balancing lamination on other side Sqm 6
92
21.3
Providing and fixing glazing in aluminium door, window,
ventilator shutters and partitions etc. with EPDM rubber / neoprene
gasket etc. complete as per the architectural drawings and the
directions of Engineer-in-Charge. (Cost of aluminium snap beading
sh
92.121.3.2 With float glass panes of 5.50 mm thickness
Sqm 6
Page 19 of 40
In Figures In Words
Item
No
DSR Item
No.Description Qty Units
RateTotal
93
22.2
Providing and laying APP (Atactic Polypropylene Polymer)
modified prefabricated five layer 3 mm thick water proofing
membrane, black finished reinforced with non-woven polyester
matt consisting of a coat of bitumen primer for bitumen membrane
@ 0.40 litre / sqm by the same membrane manufacture of density at
25°C, 0.87-0.89 kg/ litre and viscocity 70-160 cps. Over the primer
coat the layer of membrane shall be laid using Butane Torch and
sealing all joints etc., and preparing the surface complete. The vital
physical and chemical parameters of the membrane shall be as
under : Joint strength in longitudinal and transverse direction at
23°C as 650/450N/5 cm. Tear strength in longitudinal and
transverse direction as 300/250N. Softening point of membrane not
less than 150°C. Cold flexibility shall be upto -2°C when tested in
accordance with ASTM, D - 5147. The laying of membrane shall be
got done through the authorised applicator of the Manufacturer of
membrane :
93.122.20.1 3 mm thick
Sqm 50
94
22.5
Providing and laying water proofing treatment in sunken portion
of WCs, bathroom etc., by applying cement slurry mixed with
water proofing cement compound consisting of applying : a) First
layer of slurry of cement @ 0.488 kg /sqm mixed with water proofinSqm 25
95
23.1
Boring/drilling bore well of required dia for casing/ strainer pipe, by
suitable method prescribed in IS: 2800 (part I), including collecting
samples from different strata, preparing and submitting strata
chart/ bore log, including hire & running charges of all equipments,
tools, plants & machineries required for the job, all complete as per
direction of Engineer -in-charge, upto 90 metre depth below
ground level.
95.123.1.1.1 300 mm dia
Mtr 100
Page 20 of 40
In Figures In Words
Item
No
DSR Item
No.Description Qty Units
RateTotal
96
23.2
Boring/drilling bore well of required dia for casing/ strainer pipe, by
suitable method prescribed in IS: 2800 (part I), including collecting
samples from different strata, preparing and submitting strata
chart/ bore log, including hire & running charges of all equipments,
tools, plants & machineries required for the job, all complete as per
direction of Engineer -in-charge, beyond 90 metre & upto 150
metre depth below ground level.
96.123.2.1.1 300 mm dia
Mtr 100
97
23.3
Supplying, assembling, lowering and fixing in vertical position in
bore well, unplasticized PVC medium well casing (CM) pipe of
required dia, conforming to IS: 12818, including required hire and
labour charges, fittings & accessories etc. all complete, for all
depths, as per direction of Engineer -in-charge.
97.123.3.3 200 mm nominal size dia (For Dispensaries where ever required)
Mtr 100
98
23.4
Supplying, assembling, lowering and fixing in vertical position in
bore well unplasticized PVC medium well screen (RMS) pipes with
ribs, conforming to IS: 12818, including hire & labour charges,
fittings
& accessories etc. all complete, for all depths, as per direction of
Engineer-in-charge.
98.123.4.3 200 mm nominal size dia(For Dispensaries where ever required)
Mtr 100
991214 Welding by gas plant
cm 1
1001215 Welding by electric plant
cm 1
1011366 CI Grating 150x150mm
Each 20
1021927
Supply of brass way valve with C.I. wheel of approved quality
(screwed end) 25mm dia: Each 20
Page 21 of 40
In Figures In Words
Item
No
DSR Item
No.Description Qty Units
RateTotal
1031928
Supply of brass way valve with C.I. wheel of approved quality
(screwed end) 32 mm dia: Each 2
1041929
Supply of brass way valve with C.I. wheel of approved quality
(screwed end) 40 mm dia: Each 50
1051930
Supply of brass way valve with C.I. wheel of approved quality
(screwed end) 50 mm dia: Each 1
1061931
Supply of brass way valve with C.I. wheel of approved quality
(screwed end) 65 mm dia: Each 3
1071932
Supply of brass way valve with C.I. wheel of approved quality
(screwed end) 80 mm dia: Each 2
1087257 Supply of CP Brass bib cock 15mm dia
Each 150
1097259 Supply of CP Brass long body bib cock 15mm dia
Each 50
1107260 Supply of CP Brass stop cock 15mm dia
Each 50
1117261 Supply of C.P. Brass angle valve 15 mm
Each 100
112
DSR
Labour
rates
Labour charges for maintaining day to day maintenance works at
Offices, Dispensaries and residential quarters and attending to
repairs with the maintenance staff with all helpers, tools and plants
as directed the Engineer-in-charge as below :
0122 Plumber 4 NosMonth 48
0115 Plumber Helper 4 NosMonth 48
0122 Sewerman 4 NosMonth 36
0115 Sewerman Helper 4 NosMonth 36
0111 Carpenter 1 NoMonth 12
115 Carpenter Helper 1 NoMonth 12
Page 22 of 40
In Figures In Words
Item
No
DSR Item
No.Description Qty Units
RateTotal
122 Mason 1 NoMonth 12
115 Mason Helper 1 NoMonth 12
MR SupervisorMonth 12
113 120 Suppying and fixing of gun metal check valve
120 (vi) 20mmEach 1
120 (v) 25mmEach 1
120 (iv) 32mmEach 1
120 (iii) 40mmEach 1
120 (ii) 50mmEach 1
120 (i) 65mmEach 1
114 SSR 119 Supplying and fixing of GI Tee
D-VI 15mm diaEach 1
D-V 20mm diaEach 1
D-IV 25mm diaEach 1
D-III 32mm diaEach 1
D-II 40mm dia Each 1
D-I 50mm dia Each 1
115 SSR 119 Supplying and fixing GI Bend
C-VI 15mm Each 1
Page 23 of 40
In Figures In Words
Item
No
DSR Item
No.Description Qty Units
RateTotal
C-V 20mmEach 1
C-IV 25mm Each 1
C-III 32mmEach 1
C-II 40mm dia Each 1
C-I 50mm dia Each 1
116 SSR 119 Supplying and fixing GI elbow
B-IV 15mm dia Each 1
B-V 20mm diaEach 1
B-IV 25mm dia Each 1
B-III 32mm dia Each 1
B-II 40mm dia Each 1
B-I 50mm dia Each 1
117 SSR 119 Supplying and fixing reducer
F-I 50x40mm diaEach 1
F-II 40x32mm diaEach 1
F-III 32x25mm diaEach 1
F-IV 25x20mm diaEach 1
118 SSR 119 Supplying and fixing of hex nipple
Page 24 of 40
In Figures In Words
Item
No
DSR Item
No.Description Qty Units
RateTotal
I-I 50 mm diaEach 1
I-II 40 mm diaEach 1
I-III 32 mm dia Each 1
I-IV 25 mm dia Each 1
I-V 20 mm dia Each 1
I-VI 15 mm diaEach 1
119
SSR
143/P51
Supply and Fixing of C.I Nahani / Floor trap with Stainless Steel
grating 100 x 75 mm Each 25
120MR Jaquar make continental series code no. 037 bibcock
Each 20
121MR Jaquar make continental series code no. 053 angular cock
Each 20
122MR Jaquar make continental series Bottle Trap
Each 20
123
MR
Cleaning of septic tanks, manholes, pipe lines by pumping
out/removal of the sludge and sewage with mechanically operated
vaccum based septic tank cleaner including disposal of sludge far
away from the ESIC campus by mechanical transporation using
covered tanks without disturbing the public life etc. complete as per
the direction of the Engineer-in-charge. Cum 651.2
124
MRCleaning the storm water drain around the office campus by using
necessary tools and plants as directed etc. complete.Mtr 400
125
MR
Cleaning the over head tank of various sizes in terrace by using
pressure air jet method, with required detergent etc. complete (3
times) Liter 16000
Page 25 of 40
In Figures In Words
Item
No
DSR Item
No.Description Qty Units
RateTotal
126
MRCleaning the over head tank of higher capacity by using pressure
air jet method, with required staging detergent etc. complete Liter 800000
127
MRCleaning the under ground sump of various sizes by pressure air jet
method with required detergents etc. completeLiter 400000
128
MR
Providing and fixing square-mouth S.W. gully trap grade 'A'' water
tight of 300x300mm : 100x100 mm size P type With F.P.S. Bricks
class designation 75 Each 20
129
MR
Providing and fixing fly proof wire gauze mesh to windows using
Saint-Gobian wire gauze With 2nd class teak wood beading alround
of 40x19 mm etc. complete as per the directions of Engineer-in-
Charge Sqm 50
130
MR
Pressure grouting to concrete members after making 12mm dia.
holes with power drill and fixing PVC nozzles in the hole made
with cement paste and dry for one day to set hard for injecting the
grouting compound i.e. void seal of M/S Pegasas or CEBEX 100 of
M/S Fosroc or Equivalent mixed with cement and wtaer.. The void
seal or Fosroc chemical compound to be added @ 125 gm per bag of
cement and mixed with water to make slurry ready to inject. The
prepared grouting compound to be injected with grouting
equipment at 140 psi pressure and cutting the PVC nozzles, sealing
holes and making good all the treated area etc. complete as per the
directions of Engineer-in-Charge Pt 10
131
MR
Removing loose concrete cover and cleaning the damaged RCC
portion such as beams, slabs, RCC wall, applying rust remover,
rusticide, Dr,fixit, Pidilite propduct or, equavalent, allow 24 hrs
time, apply chemical Zinchromite, Zincovit to harden the loose
portion, apply cement mortor 1:3 with nice sand adding super latex
at mixture neatly over the affected surface for finishing and allow
time 24 hours etc complete Sqm 10
132
MR
Relaying Cuddapah slab for cupboard slabs and medai etc.
including pointing with cement mortar 1:3 to the full depth of slab
etc. complete. Sqm 70.88
Page 26 of 40
In Figures In Words
Item
No
DSR Item
No.Description Qty Units
RateTotal
133
MR
Providing Horticulture works with the specification ; 1. Clearing the
ground surface. 2.Fine dressing the ground. 3.Ternching the ground
by 30 to 40 C, earth filling with good earth including transport
charges 4. Uprooting the weeds and dispossing of from the site 5.
Supplying of mannure and seldge at site and mixing the same in the
ratio of 2 parts of earth to 1 part of mannure an spreding throughly
including necessary transporting charges and lift charges & planting
hedges and shurbs including watering and maintaining for a period
of 6 months Sqm 20
134MR
Supplying and fixing of Vertical blind of good quality as approved
by Enignner incharge for Windows Sqm 20
135MR Supplying and providing PVC Lids for Water storage tanks
Each 25
136MR
Supplying and providing Good quality of Steel Cupoard with
drawer arrangment for counters. Each 5
137MR Water meter (including testing charges) 80 mm
Each 1
138MR Water meter (including testing charges) 100mm
Each 1
139
MR
Provision for cleaning the sewage pump room wells using with
tripod, stand, pully, chain block, bucket coir split bamboos and
spurn yarn including removing the deposited silt and sediments
depositing in one place and convey away from the site as directed
by the departmental officers. Job 2
140
M.R
Repairs to Kulatheri main pipe line Removing existing pipe
line,aresting the leakages with required new pipe, specials, earth
work, dewatering, packing, packing materials, concrete cutting,
threading, shellac, thread ball, etc.,Job 2
Page 27 of 40
In Figures In Words
Item
No
DSR Item
No.Description Qty Units
RateTotal
.
1.8
Wiring for light point/ fan point/ exhaust fan point/ call bell point
with 1.5 sq.mm FR PVC insulated copper conductor single core
cable in surface / recessed medium class PVC conduit, with piano
type switch, phenolic laminated sheet, suitable size M.S. box and
earthing the point with 1.5 sq.mm. FR PVC insulated copper
conductor single core cable etc as required.
141.11.8.2 Group B
Point 341
142
1.9
Wiring for twin control light point with 1.5 sq.mm FR PVC
insulated copper conductor single core cable in surface / recessed
medium class PVC conduit, 2 way piano type switch, phenolic
laminated sheet, suitable size MS box and earthing the point with
1.5 sq.mm. FR PVC insulated copper conductor single core cable etc
as required. Point 100
142
1.11
Wiring for twin control light point with 1.5 sq.mm FR PVC
insulated copper conductor single core cable in surface / recessed
medium class PVC conduit, 2 way modular switch, modular plate,
suitable GI box and earthing the point with 1.5 sq.mm. FR PVC
insulated copper conductor single core cable etc as required.Point 7
143
1.10
Wiring for light point/ fan point/ exhaust fan point/ call bell point
with 1.5 sq.mm FRLS PVC insulated copper conductor single core
cable in surface / recessed medium class PVC conduit, with modular
switch, modular plate, suitable GI box and earthing the point with
1.5 sq.mm. FRLS PVC insulated copper conductor single core cable
etc. as required.
143.1 1.10.2 Group B Point 272
144
1.12
Wiring for light/ power plug with 2X4 sq. mm FR PVC insulated
copper conductor single core cable in surface/ recessed medium
class PVC conduit alongwith 1 No 4 sq. mm FR PVC insulated
copper conductor single core cable for loop earthing as required.Mtr 1650
Page 28 of 40
In Figures In Words
Item
No
DSR Item
No.Description Qty Units
RateTotal
145
1.13
Wiring for light/ power plug with 4X4 sq. mm FR PVC insulated
copper conductor single core cable in surface/ recessed medium
class PVC conduit alongwith 2 Nos 4 sq. mm FR PVC insulated
copper conductor single core cable for loop earthing as required.Mtr 75
146
1.14
Wiring for circuit/ submain wiring alongwith earth wire with the
following sizes of FR PVC insulated copper conductor, single core
cable in surface/ recessed medium class PVC conduit as required
146.11.14.1 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
Mtr 1650
146.21.14.2 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
Mtr 2150
146.31.14.8 4 X 4 sq. mm + 2 X 4 sq. mm earth wire
Mtr 250
146.41.14.9 4 X 6 sq. mm + 2 X 6 sq. mm earth wire
Mtr 230
147
1.17
Supplying and drawing following sizes of FRLS PVC insulated
copper conductor, single core cable in the existing surface recessed
steel / PVC conduit as required
147.11.17.1 1 x 1.5 sq.mm
Mtr 10
147.21.17.11 2 x 2.5 sq.mm
Mtr 10
147.81.17.20 2 x 4 sq.mm
Mtr 10
148
1.18
Supplying and drawing following pair 0.5 mm dia FRLS PVC
insulated annealed copper conductor, unarmored telephone cable
in the existing surface / recessed steel / PVC conduit as required
148.11.18.1 1 pair
Mtr 10
148.21.18.2 2 pair
Mtr 10
148.31.18.3 4 pair
Mtr 10
Page 29 of 40
In Figures In Words
Item
No
DSR Item
No.Description Qty Units
RateTotal
149
1.19
Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid
copper conductor PE insulated, shielded with fine tinned copper
braid and protected with PVC sheath in the existing surface
recessed steel / PVC conduit as requiredMtr 20
150
1.21
Supplying and fixing of following sizes of medium class PVC
conduit along with accessories in surface / recess including cutting
the wall and making good the same in case of recessed conduit as
required
150.11.21.1 20 mm
Mtr 50
150.21.21.2 25 mm
Mtr 50
151
1.23Supplying and fixing following piano type switch/ socket on the
existing switch box/ cover including connections etc. as required.
151.11.23.1 5/6 amps switch
Each 185
151.21.23.2 2 way 5/6 amps switch
Each 30
151.31.23.3 15/16 amp switch
Each 95
151.41.23.4 3 pin 5/6 amp socket outlet
Each 95
151.51.23.5 6 pin 15/16 amp socket outlet
Each 55
151.61.23.8 Bell bush
Each 42
152
1.24
Supplying and fixing following modular switch/ socket on the
existing modular plate & switch box including connections but
excluding modular plate etc. as required.
152.11.24.1 5/6 amps switch
Each 190
152.21.24.3 15/16 amp switch
Each 55
152.31.24.4 3 pin 5/6 amp socket outlet
Each 190
Page 30 of 40
In Figures In Words
Item
No
DSR Item
No.Description Qty Units
RateTotal
152.41.24.5 6 pin 15/16 amp socket outlet
Each 95
152.51.24.8 Bell push
Each 11
153
1.25
Supplying and fixing stepped type electronic fan regulator on the
existing modular plate switch box including connections but
excluding modular plate etc. as required. Each 100
154
1.26Supplying and fixing modular blanking plate on the existing
modular plate & switch box excluding modular plate as required.Each 155
155
1.27
Supplying and fixing following size/ modules, GI box alongwith
modular base & cover plate for modular switches in recess etc as
required.
155.11.27.1 1 or 2 Module (75mmX75mm)
Each 200
155.21.27.2 3 Module (100mmX75mm)
Each 226
155.31.27.3 4 Module (125mmX75mm)
Each 250
155.41.27.4 6 Module (200mmX75mm)
Each 110
155.51.27.5 8 Module (125mmX125mm)
Each 73
156.61.27.6 12 Module (200mmX150mm)
Each 58
1561.28
Supplying and fixing following modular base and cover plate on
existing modular metal box etc. as required.
156.11.28.1 1 or 2 Module
Each 190
156.21.28.2 3 Module
Each 190
156.31.28.3 4 module
Each 190
Page 31 of 40
In Figures In Words
Item
No
DSR Item
No.Description Qty Units
RateTotal
156.41.28.4 6 module
Each 190
156.51.28.5 8 module
Each 190
156.61.28.6 12 module
Each 190
157
1.31
Supplying and fixing suitable size GI box with modular plate and
cover in front on surface or in recess, including providing and fixing
3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch,
connection etc. as required. (For light plugs to be used in non
residential buildings). Each 170
158
1.32
Supplying and fixing suitable size GI box with modular plate and
cover in front on surface or in recess, including providing and fixing
6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps
modular switch, connection etc. as required.Each 93
1591.38
Supplying and fixing call bell/ buzzer suitable for single phase, 230
volts, complete as required. Each 16
1601.53
Supplying and drawing of UTP 4 pair CAT 6 Lan cable in existing
surface / recessed steel / PVC conduit as required Mtr 300
161
2.18
Supplying and fixing 20 amps, 240 volts, SPN industrial type, socket
outlet, with 2 pole and earth, metal enclosed plug top alongwith 20
amps "C" curve, SP, MCB, in sheet steel enclosure, on surface or in
recess, with chained metal cover for the socket out let and complete
with connections, testing and commissioning etc. as required.Each 43
162
5.2
Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including
accessories, and providing masonry enclosure with cover plate
having locking arrangement and watering pipe etc. with charcoal/
coke and salt as required. Each 25
163
7.1
Laying of one number PVC insulated and PVC sheathed / XLPE
power cable of 1.1 KV grade of following size direct in ground
including excavation, sand cushioning, protective covering and
refiiling the trench etc as required
Page 32 of 40
In Figures In Words
Item
No
DSR Item
No.Description Qty Units
RateTotal
163.17.1.1 Upto 35 sqmm
Mtr 50
163.27.1.2 Above 35 sqmm and Upto 95 sqmm
Mtr 50
163.32904 8 SWG copper wire (4.0 mm dia)
kg 38
164
9.1
Supplying and making end termination with brass compression
gland and aluminium lugs for following size of PVC insulated and
PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade
as required.
164.19.1.2 2 X 10 sq. mm (19mm)
Each 30
164.29.1.4 2x25 Sqmm
Each 8
164.39.1.7 3 x 10 Smm
Each 5
1651101
1.5 sq. mm ISI marked, FR PVC insulated, single core copper
conductor cable Mtr 50
1661102
2.5 sq. mm ISI marked, FR PVC insulated, single core copper
conductor cable Mtr 50
1671103
4.0 sq. mm ISI marked, FR PVC insulated, single core copper
conductor cable Mtr 50
1681104
6.0 sq. mm ISI marked, FR PVC insulated, single core copper
conductor cable Mtr 50
1691110
32/0.20mm (1 sqmm) twin circular FRLS PVC sheathed, workshop
flexible copper cable Mtr 50
170 1436 Bell push, piano type Each 50
1711706
6 amps. to 32 amps. ratings , SP MCB, "C" curve, 10 KA breaking
capacity Each 150
1721708
6 amps. to 32 amps. ratings , DP MCB, "C" curve, 10 KA breaking
capacity Each 50
1731709
6 amps. to 32 amps. ratings , TP MCB, "C" curve, 10 KA breaking
capacity Each 14
Page 33 of 40
In Figures In Words
Item
No
DSR Item
No.Description Qty Units
RateTotal
1741712 40 amps., 2 pole isolator
Each 50
1751740 12 way SPN Double door MCB DB
Each 20
176
2.12
Supplying and fixing following rating, double pole, 240 volts,
isolator in the existing MCB DB complete with connections, testing
and commissioning etc. as required.
1762.12.1 40 Amps
Each 25
1772.12.2 63 amps
Each 20
178
2.13
Supplying and fixing following rating, four pole, 415 volts, isolator
in the existing MCB DB complete with connections, testing and
commissioning etc. as required.
1782.13.1 40 Amps
Each 10
1792.13.2 63 amps
Each 20
1802.13.3 100 amps
Each 13
181
2.3
Supplying and fixing following way, single pole and neutral, sheet
steel, MCB distribution board, 240 volts, on surface/ recess complete
with tinned copper bus bar, neutral bus bar, earth bar, din bar,
interconnections, powder painted including arthing etc. as required.
(But without MCB/RCCB/Isolator)
181.12.3.1 2 + 4 way/ 6 way , Double door
Each 2
1822.3.2 2 + 6 way/ 8 way , Double door
Each 20
1832.3.3 2 + 10 way/ 12 way , Double door
Each 2
1842.3.4 2 + 14 way / 16 way, Double door
Each 10
Page 34 of 40
In Figures In Words
Item
No
DSR Item
No.Description Qty Units
RateTotal
185
2.4
Supplying and fixing following way, horizontal type three pole and
neutral, sheet steel, MCB distribution board, 415 volts, on surface/
recess, complete with tinned copper bus bar, neutral bus bar, earth
bar, din bar, interconnections, powder painted including earthing
etc. as required. (But without MCB/RCCB/Isolator)
2.4.4 4 way (4 + 12), Double doorEach 2
186
11.3
Erection of metallic pole of following length in cement concrete
1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm
nominal size) foundation including excavation and refilling etc. as
required.
11.3.1 Above 4.5 mtr and upto 6.5 mtrEach 25
188
1.17
Supplying and drawing following sizes of FRLS PVC insulated
copper conductor, single core cable in the existing surface/ recessed
steel/ PVC conduit as required.
1891.17.21 3 x 4 sq. mm
Mtr 25
1891.17.30 3 x 6 sqmm
Mtr 25
1911442 Brass batten/ angle holder
Each 50
192
Labour charges for day to day maintenance works at Hospital, Staff
Quarters and 3 dispensaries, staff quarters and attending to repairs
round the clock with maintenance staff with all helpers, tools, as
directed by the Engineer in charge.
1004 Electrician Grade I - 5 NosMonth 60
1005 Electrician Grade II- 5 NosMonth 60
Page 35 of 40
In Figures In Words
Item
No
DSR Item
No.Description Qty Units
RateTotal
1004 Pump Driver- 2 NosMonth 24
1004 Lift Operator- 4 NosMonth 60
MR Supervisor "C" License HolderMonth 12
193
SD-125
Supply and fixing of TNEB meter Board suitable for 32A Single
Phase service connection with 32A Fuse unit (500V) 32A neutral
link and earth link (1" x 1/8" Copper flat) on TW plank of size
375mm x 300mm x 19mm with supporting TW reepers of 1" thick
an either side with painting with suitable bolt and nuts for fixing
the TW plank on wall with earth connection and inter connection
with 7/20 PVC insulated copper wire from EB meter to fuse unitEach 5
194
SD -127
Supply and fixing of TNEB meter Board suitable for 32A Three
Phase service connection with 3 Nos. 32A Fuse unit (500V) 32A
neutral link and earth link (1" x 1/8" Copper flat) on TW plank of
size 600mm x 450mm x 19mm with supporting TW reepers of 1"
thick an either side with painting with suitable bolt and nuts for
fixing the TW plank on wall with earth connection and inter
connection with 7/20 PVC insulated copper wire from EB meter to
fuse unit. Each 5
195
SD - 198
Supply and laying of 2x10 Sqmm PVC armoured LT UG Cable in a
trench to be excavated at a depth of 0.75 mtr putting 0.15 mtr layer
of sand and covering the cable completely with bricks and sand and
refiiling the earth to make goodMtr 460
196
SD-200
Supply and laying of 2x25 Sqmm PVC armoured LT UG Cable in a
trench to be excavated at a depth of 0.75 mtr putting 0.15 mtr layer
of sand and covering the cable completely with bricks and sand and
refiiling the earth to make goodMtr 1200
Page 36 of 40
In Figures In Words
Item
No
DSR Item
No.Description Qty Units
RateTotal
197
SD 88
Supply and fixing of single box type 4'40 W flu fitting complete
with copper choke and condensor with TW round blocks on wall or
ceiling with flu tube with PVC unsheathed copper leads from
terminals to the fitting. Each 90
198B.1.a
A.C. ceiling fan complete 1200mm ( 48") sweep with 300mm down
rod (without regulator) ( crompton make) Each 110
199
SD 114
Supply and fixing of 300 mm ( 12" ) sweep (light duty) AC exhaust
fan complete with necessary wall opening and making good the
wall. Each 26
200 A-15 Polyster filled copper choke 250 V/50 Hz grade suitable
c 36/40 W Electronic ballast for flu typeEach 90
201 A-4 Fluorescent tubular lamps with ISI mark
b Cool day light 4 ft 40 Watts Each 340
202A-14-b Starter for flu tube 40 Watts
Each 180
203C.2.b 32AmpsDP switch with metal clad ( Front handle )
Each 7
204C.3.a 100 Amps TPN switch with HRC fuces sheet steel double break.
Each 7
205B.5.b 32 Amps porcelein fuce unit ( 500 V)
Each 7
206B.5.c 63 Amps porcelein fuce unit ( 500 V)
Each 16
207B.5.d 100 Amps porcelein fuce unit ( 500 V)
Each 16
208A.3.d 36Watts CFL Bulb
Each 100
209A.3.c 18Watts CFL Bulb
Each 100
Page 37 of 40
In Figures In Words
Item
No
DSR Item
No.Description Qty Units
RateTotal
210J.1.a T.W Box conceiled type 12" x 8" x 3"
Each 70
211J.1.b T.W Box conceiled type 8" x 6" x 3"
Each 35
212J.1.c T.W Box conceiled type 6" x 4" x 3"
Each 60
213J.1.d T.W Box conceiled type 4" x 4" x 3"
Each 30
214I.8.a Insulation Tape roll
Each 60
215
SD 36
Wiring with 2 x 1.5 swmm ( 22/0.3) PVC insulated SC unsheathed
Cu. Conductor of 1100 V grade in suitable PVC rigid pipe on wall
and ceiling with PVC accessories with 150 x 100 x 113 mm TW
switch box for 5 A 3 pin non inter locking CS plug with painting of
suitable colour with continious earth wire connection of 14 SWG TC
wire for open PVC plug point.Point 60
216
SD 39
Wiring with 2 x 4 sqmm (56/0.3 ) PVC insulated SC unsheathed Cu.
Conductor of 1100 V grade in suitable PVC rigid pipe conceiled in
wall and ceiling with PVC accessories. In flush with wall, with
150mm x 100mm x 113mm TW switch box with 3 mm thick Hylem
sheet cover for 5 A 3 pin non inter locking CS plug with continious
earth wire connection of 14 SWG TC wire and making good of the
consealed portion with suitable colour for concealed PVC plug
point. Point 30
Total of SSR Items
217DATA
Supplying and fixing of 2 x 36 W CFL Street light fitting with 36W
CFL Each 50
218MR Supply of 400mm sweep wall bracket fan with push button switch
Each 25
219MR Supply of 2.5 MFD Fan condensor
Each 60
Page 38 of 40
In Figures In Words
Item
No
DSR Item
No.Description Qty Units
RateTotal
220MR 400mm sweep pedestral fan
Each 8
221MR EBT2 18 W Choke
Each 80
222MR EBT 236 TLD 36W Choke
Each 40
223MR
Annual Maintenance to 1.5/2 ton window model/ Split type Air
Condition. Each 156
224MR
Charges for Breake down and Gas Charging to 1.5/2 ton window
model/ Split type Air Condition Unit. Kg 20
225MR Capacitor
Each 20
226
MR
GEM make starter (New) Panel with star delta starter, single phase
preventor, 4 pole MCB in corner / volt meter, pilot lamp with
switch complete with sheet steel enclosure and internal and earth
connections. Each 3
227MR Texmo 15 stage submersible pump.(15 Hp Bore well 250 ft depth)
Each 1
228MR Repairing of starter pannel including spares.
Each 4
229MR Repairing Various HP motor and rewinding including spares
a 5 - 7.5 HPEach 4
b 10 - 15HP Each 2
230MR
Monthly maintenance of 2000 KVA 440 V Diesel Generator
(caterpillar make) ( 1 No) Each 1
231MR Engine oil
Ltr 150
232MR Charges for supply of Oil filter
Each 10
233MR Charges for supply of Diesel filter
Each 10
234MR Charges for supply of Radiator coolent
ltr 20
Page 39 of 40
In Figures In Words
Item
No
DSR Item
No.Description Qty Units
RateTotal
235MR Charges for supply of distilled Water.
Ltr 20
236MR Supply of diesel for 2000 KVA DG Set
Ltr 18000
237MR OCB Servicing
Each 2
238MR 4 KVA Stabilizer
Each 3
239 MR Supply of following chemicals for the RO plant
a Sodium Metabi SulphiteKg 432
b Anti scalentLtr 432
TOTAL
Page 40 of 40
Recommended