View
88
Download
7
Category
Tags:
Preview:
DESCRIPTION
Kiln Burners
Citation preview
Fives Pillard 1
COMBUSTION IN ROTARY KILNS& PRECALCINERS
NEW TARGETS AND SOLUTIONS
Fives Driving Progress
Fives Pillard 2
Brief overview of Fives Pillard, Marseilles, France...
J.C.P.
3Fives Pillard
Kiln burner concepts of the 90's
BURNERS WITH AXIAL & RADIAL
CHANNELSADJUSTABLE AT SITE
The ROTAFLAM burner
FIXED BURNER HIGH IMPULSE
LIMITING MISTAKES OF OPERATORS
The traditional burner
versus
(+) Can be tuned to each kiln at site
(-) Difficult to adjustComplexHeavy
The two concepts have been applied for over 15 years,both have shown their limits none is a clear winner.
NEW PATENTSDE 3933050C2 of Oct. 4, 1989EP 90.430017.5 of Sept.14,1990
(+) Avoid mistakes ofoperators
(-) Damages on refractoriesHigh NOx emissionLimited adjustmentsSticking on tips
4Fives Pillard
New (priority) millennium targets
Target YearAssess burner operation in a kiln, using Fluent CFD softwareCement kiln simulations1 1999
Develop the use of Alternative Solid Fuels (A.S.F.) in EuropePowders (animal, biomass, urban) and "Fluff"
Decrease the running costs of European Cement PlantsBy conversion to high % of A.S.F.
Put Clinker quality as a priority(+) The Sulphur cycle must be improved
Address new Sustainable development requirementsReducing CO and NOx emission AT STACK
2001-
2005Simplify burners use : the NOVAFLAM burnerImprove precalciners / Urea Ammonia injection
2000-
2004
2 2002
3 2003
4
5
6 2005Control combustion in real time
Fives Pillard 5
Target 1:
Assess burner operation in a kiln,using Fluent CFD software
6Fives Pillard
First cement kiln simulations (with Fluent CFD software)
The Fluent CFD tool allows to compare burner tip geometries
Stream lines around flames
Question : Are there big recirculation areas inside the kiln ?
Answer : NoExtract from competitor article
UNTRUE
High intensity flameLong lazy flame
Question : Can we evaluate the influenceof flame intensity on theclinker bed ?
Answer : Yes
Bad air distribution(white cement)
Improved
Question : What is the influence of airdistribution ?
Answer : essentialMUST be optimized first
Fives Pillard 7
Target 2:
Develop the use of A.S.F. in Europe
8Fives Pillard
A.S.F.: how to improve the combustion of fluff ?
First dispersor New dispersor (2005)
NEW PATENTSFR 9808254 of June 24, 1998EP 99.430010.1 of June 23, 1999
; A fast dispersion into the flameA new "fluff dispersor" has been developed
Fluff being heterogeneous, its combustion requires:
Suction of secondary air Radiation on clinker
; An acceleration of the combustion, by SLOT EFFECT, enabling
to Adapt the amount of Hot Secondary Air(H.S.A.) introduced in the flame
And, - as a consequence- , to affect the flame temperature
Few H.S.A. in flame,SOFT FLAME
Fast/high H.S.A. in flame,HIGH INTENSITY FLAME
Fives Pillard 9
Target 3:
Decrease the running cost of European Cement Plants by conversion to high % of A.S.F.
10Fives Pillard
The ROTAFLAM Version 2 with SLOT EFFECT
allowed for a huge increase of A.S.F. use (%)
(A.S.F.) Alternative Solid FuelsEnd user Kiln (tpd)
% Heat release Type
HOLCIM HOVER, Germany DRY 3200 75 Fluff + Animal meal ROTAFLAM V2
HEIDELBERGER LENGFURT, Germany DRY 2500 80 Fluff + Animal meal + Solvents ROTAFLAM V2
HEIDELBERGER SCHELKLINGEN, Germany DRY 2500 75 Fluff+ Dry sewage sludge ROTAFLAM V2
ROHRDORF, Germany SEMI WET 3000 80 Tetrapack, Plastic ROTAFLAM
WITTEKIND, Germany DRY 2500 52 Bram ROTAFLAM V2
DYCKERHOFF, DEUNA, Germany DRY 3000 50 Fluff + Plastic ROTAFLAM
HOLCIM ECLEPENS, Switzerland DRY 2000 30 Sawdust + Animal meal ROTAFLAM V2
Burner
11Fives Pillard
The ROTAFLAM Version 2 with SLOT EFFECT
Focus on Holcim plant, Hver (G) : Clinker quality improved and Fluff consumption increased
up to 75 %, i.e. 13 tons/hr
NEW PATENTSFR 0705305 of July 20, 2007EP 08.160478.7 of July 16, 2008
Fives Pillard 12
Target 4:
Put Clinker quality as a PRIORITY
Fives
13Fives Pillard
Clinker quality & Sulphur cycle
The ROTAFLAM Version 2 with "SLOT EFFECT improves the clinker quality and impedes the Sulphur cycle formation, thanks to:
No contact between flame and the clinker bed
Low diameter "cigar" shaped flame in the kiln axis
High intensity flame (DRY PROCESS), softer (WET)
End user Main fuel Kiln (tpd) Former burner New burner Improvement
TIANRUI RUIZHOU, China High ash coal 6000 ROTAFLAM 14 Mpa,production increase by 3,5 %
HOLCIM, Sri Lanka Coal + sawdust 900 ROTAFLAM 30 Mpa
Fives Pillard 14
Target 5:
Address New Sustainable development requirements
15Fives Pillard
Sustainable development : a struggle against pollutants
NEW PATENT: EP 04.290293.2 of Feb.4, 2004
CO and NOx reduction at stack needs FIRST to limit them AT KILN INLET !
Patented concept: Low NOx Tips, joint development between Italcementi & Fives Pillard(Grant awarded from the European Community) :
0
200
400
600
800
1000
1200
1400
0 1 2 3 4 5 6 7
OXYGEN (%)
N
O
x
(
m
g
/
N
m
3
@
1
0
%
O
2
)
-
2
8
%
-
4
6
%
-
2
4
%
ORIGINAL
1ST LOW NOX
TIP
2ND LOW NOX TIP
NOx AT KILN INLET
DIFFERENTBURNER TIPS
First tests at ITALCEMENTI's SARCHE plant (It) (1997-2001), confirmed in ITALCEMENTI's BRONI plant (It) (2002-2004) tests led to developing special LOW NOx tips.
16Fives Pillard
Sustainable development : a struggle against pollutants
Low NOx tips have proven sizeable benefits
End User Kiln (tpd) Main fuel NOx at kiln inlet@ 10% O2 dry Improvements (NOx reduction, capacity)ITALCEMENTI SALERNO, Italy 1400 Petcoke 1020 Increase production from 1300 to 1400 tpd. in a narrow furnace
ITALCEMENTI BRONI, Italy 730 Petcoke 775 NOx reduction -46% compared with previous ITC burner
ITALCEMENTI SARCHE, Italy 800 Petcoke 1020 NOx reduction -29% compared with the Monochannel burner in narrow furnace -
ITALCEMENTI SCAFA, Italy 950 Petcoke 1063 NOx reduction -26% compared to the previous ROTAFLAM
ITALCEMENTI CALUSCO, Italy 4000 Petcoke 510 Good performances - fully satisfied (new plant)
CALCIA VILLIERS, France 1200 Coal 880 Kiln more stable and use of a higher LSF meal with same NOx emission
CCB GAURIN, Belgium 1650 Petcoke 755 NOx reduction -30% compared to the previous ROTAFLAM
HOLCIM MERONE, Italy 2300 Petcoke 730 NOx reduction -27 % compared to the previous ROTAFLAM
ITALCEMENTI COLLEFERO, Italy 2300 Petcoke 920 NOx reduction -17% compared to FLS and no hot spot
ITALCEMENTI VASSILIKO, Cyprus 6000 Coal Under com.
17Fives Pillard
Prediction software for NOx emissions at kiln inlet
Coal concentration
0
200
400
600
800
1000
1200
0.5 1 1.5 2 2.5 3 3.5kg coal/Kg (Transport +Central) air
N
O
x
(
m
g
/
N
m
3
@
1
0
%
O
2
)
Tip position in the kiln
200
400
600
800
1000
1200
0 0.05 0.1 0.15 0.2 0.25 0.3(m/m)
N
O
x
(
m
g
/
N
m
3
@
1
0
%
O
2
)
Primary air amount
0
200
400
600
800
1000
1200
6 8 10 12 14(%)
N
O
x
(
m
g
/
N
m
3
@
1
0
%
O
2
)
Secondary air temperature
0
200
400
600
800
1000
1200
700 800 900 1000 1100 1200 1300Temperature (C)
N
O
x
(
m
g
/
N
m
3
@
1
0
%
O
2
)
O2 at kiln inlet
0
200
400
600
800
1000
1200
1 2 3 4 5 6O2 (% dry basis)
N
O
x
(
m
g
/
N
m
3
@
1
0
%
O
2
)
The Fives Pillard NOx ROTA software allows to separate the influencing factors of NOx emission.The use of computerized multi points measurements is mandatory.
Influencing factors:0
200
400
600
800
1 000
1 200
1 400
1 600
N
O
x
m
g
/
N
m
3
@
1
0
%
d
'
0
2
NOx calculatedNOx Measured
Specific heat per m3 Material flow density
0
200
400
600
800
1000
1200
0.15 0.2 0.25 0.3 0.35 0.4(MW/m3 )
N
O
x
(
m
g
/
N
m
3
@
1
0
%
O
2
)
0
200
400
600
800
1000
1200
0.6 1 1.4 1.8 2.2(MW.s/Kg)
N
O
x
(
m
g
/
N
m
3
@
1
0
%
O
2
)
200
300
400
500
600
700
800
900
0,0 2,5 5,0 7,5 10,0 12,5 15,0 17,5 20,0Refuse @ 90 mm
N
O
x
m
g
/
N
m
3
@
1
0
%
O
2
Coal fineness
200
300
400
500
600
700
800
900
1000
0 10 20 30 40Volatiles %
N
O
x
m
g
/
N
m
3
@
1
0
%
O
2
Volatiles
200
300
400
500
600
700
800
900
1000
0,5 1,5 2,5 3,5%/m2
N
O
x
(
m
g
/
N
m
3
@
1
0
%
O
2
)
Burner swirl
The 800 mg/Nm3@10%O2 target at kiln inlet is achievable !
Fives Pillard 18
Target 6:
Simplify burner use : the NOVAFLAM burner
Improve Precalciners / Urea Ammonia injection
Control combustion in real time
19Fives Pillard
The NOVAFLAM burner : a simplified use
From the ROTAFLAM to the NOVAFLAM burner
ROTAFLAM NOVAFLAMROTAFLAM Version2Burners with axial & swirl channels adjustable at site
Tailor-made" engineered designAllows much more simple adjustmentsAddition of "slot effect"
Main features :
S.A.S. (single air supply) as standard
D.A.S. (double air supply) only for special applications,for example : LOW NOx application
burner tips engineered according to process data
NEW PATENTSEP 06.778673.1 of June 26,2006EP 07.290663.9 of May 23, 2007FR0852836 of April 28, 2008FR2009/050593 of April 07, 2009
20Fives Pillard
The NOVAFLAM burner : Input data for engineering
Process data (incl. kiln geometry); Dry or wet process, and L of kiln; Burner heat release without safety margin; LSF of raw material, sulphur content; Secondary air temperature, type of cooler, position of tip in kiln; List of fuels, concentration in conveying lines, % of each, volatiles, granulometry, sulphur content; Carriage: Can the burner be in the kiln axis ?
Running data; Past experience with the kiln (difficulties, rings, other); Priority targets (Increase prod ? Improve clinker quality ? Sulphur cycle problems ? Decrease NOx ?
Increase A.S.F. %?)
Absolutely avoid a burner oversizing
21Fives Pillard
The NOVAFLAM burner : technical design choices
primary air outletInfluence of increasing SWIRL
Flame OK
primary air outletMax velocity for 250 mb fan pressure
Max velocity # 100 m/sUnacce
ptable
primary air outletInfluence of increasing SWIRL
Flame OK Flame OK
primary air outletMax velocity for 250 mb fan pressure
Max velocity # 250 m/s
SINGLE or DOUBLE primary air outlet ?
SINGLE
DOUBLE
SINGLE
DOUBLE Adopted!
LOW SWIRL
LOW SWIRL
HIGH SWIRL
HIGH SWIRL
Unacce
ptable
Adopted!
A DOUBLE primary air outlet is mandatory
22Fives Pillard
The NOVAFLAM burner : references
ASFEnd user Main fuel Kiln (tpd) % Heat release TypeKOHAT CEMENT, Pakistan GAS / COAL DRY 6700 0 - Successfully commissioned by customer , satisfiedGHARIBWAL CEMENT, Pakistan GAS / COAL DRY 6700 0 - Successfully commissioned by customer , satisfied
HEBEI, Kuishan, China COAL DRY 5500 0 - Very satisfied, high clinker quality & production
YANBU, Saudi Arabia HEAVY FUEL OIL DRY 11000 0 - Not yet startedFUCHUAN, China HIGH ASH COAL / OIL DRY 5500 0 - Not yet startedCHIFENG YUANHANG, China HIGH ASH COAL / OIL DRY 2900 0 - StartedXIBEI CHANGYE, China HIGH ASH COAL / OIL DRY 4500 0 - Not yet startedLUOYANG TONGLI, China HIGH ASH COAL / OIL DRY 5500 0 - StartedXING KUANG CEMENT, China HIGH ASH COAL / OIL DRY 5500 0 - Not yet startedZAOZHUANG JINQAO, China HIGH ASH COAL / OIL DRY 6000 0 - Not yet startedDANGOTE CEMENT LINES 1 & 2, Nigeria HFO/GAS/COAL DRY 6000 0 - Not yet startedLARESTAN CEMENT, Iran HFO/GAS DRY 3300 0 - Not yet startedBAOARE CEMENT, Chad HFO DRY 800 0 - Not yet startedMCE CEMENT, Ethiopia HFO/GAS/COAL DRY 3000 0 - Not yet startedWUAN XINFENG CEMENT, China HIGH ASH COAL / OIL DRY 6000 0 - Not yet startedXUZHOU LONGHAN CEMENT, China HIGH ASH COAL / OIL DRY 5500 0 - Not yet startedFURONG JUNLIAN CEMENT, China HIGH ASH COAL / OIL DRY 5500 0 - Not yet startedQUINLIANSHAN MINE CEMENT, China HIGH ASH COAL / OIL DRY 2500 0 - Not yet startedTPI POLENE KILNS 1,2 & 3, Thailand COAL / FLUFF (RDF) / OIL DRY 10000 0 - Not yet startedEL NAHDA CEMENT CO., Egypt HFO/GAS DRY 7000 0 - Not yet startedCAMCE KANT LINES 1 TO 5, Kyrkystan HFO/GAS/COAL DRY 720 0 - Not yet startedCAMCE KANT LINES 6 & 7, Kyrkystan HFO/GAS/COAL DRY 504 0 - Not yet startedHENAN YONGAN CEMENT, Chine HIGH ASH COAL / OIL DRY 5800 0 - Not yet startedQUINLIANSHAN YONGDENG CEMENT, Chine HIGH ASH COAL / OIL DRY 5500 0 - Not yet startedZAOZHUANG WOFENG, Chine HIGH ASH COAL / OIL DRY 5800 0 - Not yet startedQUYANG JINYU CEMENT, Chine HIGH ASH COAL / OIL DRY 5800 0 - Not yet startedNANJING HOPE, Ethiopia HFO DRY 1700 0 - Not yet started
HOLCIM LUMBRES, France PETCOKE WET 800 30 Sawdust+ Animal meal Commissioned by customer, satisfied, sawdust flow x 2HOLCIM DANNES, France PETCOKE SEMI DRY 1200 50 Sawdust+ Animal meal Very satisfied, 70 % more sawdust (5 t/hr)SHANDONG DONGHUA, China COAL DRY 5500 0 - Very satisfied, high clinker quality & productionBEIJING LIMA, China COAL DRY 5000 0 - Very satisfied, high clinker quality with low LHV coal
GUANGZHOU, China COAL DRY 4000 20 Plastic chips Commissioning scheduled on June 2009SHANDONG QUANXING, China COAL DRY 3200 0 - Commissioning scheduled on June 2009AHLIA CEMENT, Lybia HFO/GAS DRY 3000 0 - Not yet startedCBMI AL BADIA, Syria COAL/PETCOKE DRY 5500 0 - Not yet startedVICAT KAZAKHSTAN, Kazakhstan COAL DRY 3000 0 - Not yet startedHOLCIM, OBOURG PLANT, Belgium PETCOKE WET 3000 50 Schiste / Sludge / Sawdust Commissioning scheduled on July2009
User feedback
23Fives Pillard
The NOVAFLAM burner : references
; Simplicity of adjustment confirmed.
; Intense flame, low with low primary air pressure (< 250 mbar), confirmed.
HOLCIM LUMBRES opinion: "Replacing the previous burner by the NOVAFLAM has allowed us to increase the % total kiln energy amount from impregnated sawdust from 11% in 2007 to 20% in 2008Furthermore, the NOVAFLAM is very simple to use
HOLCIM DANNES opinion: "The total substitution rate has increased by 70%... The flame is strong and intense even with pressure from 160 to 180 mbar the operators highly appreciate the burner flexibility and the simplicity of the adjustments"
24Fives Pillard
The NOVAFLAM burner : a shorter Return on Investment
RUNNING COSTS INSTALLATION COSTS
KILN PRODUCTION EXISTING CARRIAGE
Stability increased
Production increased (typically 2-4%)
A low quality coal can be used
Recovered
USE OF HIGH A.S.F. % EXISTING P.A. FAN
Cancelling fuel costs Recovered
Huge savings! Minimized!
Payback time of 8 months for the 2 HOLCIM French plants
25Fives Pillard
The NOVAFLAM burner : a lower Carbon assessment
CO2 emission ELECTRIC CONSUMPTION
Concentration can be increasedElectric Consumption: less15%
Pressure can be reducedFlow reducedElectric Consumption: less 30/40%
Consumed electricityReduced!
SPECIFIC CONSUMPTION SOLID FUELCONVEYING LINES
Reduced (average 3 %)CO2
USE of higher BIOMASS FUEL % PRIMARY AIR FAN
CO2
CO2Reduced!
Fives Pillard 26
Now, what about
Improving Precalciners
Control combustion in real time
27Fives Pillard
Improving Precalciners / Urea Ammonia injection
The Fluent studies on PRECALCINERS focused on:
NEW PATENTSEP 06.291903.0 of Dec. 11, 2006FR 06.05355 of June 15, 2006
NOVAFLAM and NEUTRINOX are complementary
; Temperature profiles and recirculation zones; Influence of (preca) burners positioning
They allow to choose the best Urea/Ammonia injection points to meet NOx limits AT STACK
Control valve set
Re-circulation zones
Levels of injection
Temperature profile
Special atomizer
The NEUTRINOX SNCR system includes : A control valve set Two levels of injectors Special atomizers
End user NOx at stackmg @10% O2, dryNOx reduction
%Efficiency
% Client's feedback
ITALCEMENTI Salerno, Italy 700 73 83 3 years of operation, easy maintenance, high reliability
ITALCEMENTI Colleferro line 5, Italy 800 72 46 2 years of operation, easy maintenance, ammonia tests pending
ITALCEMENTI Colleferro line 6, Italy 1080 60 56 2 years of operation, easy maintenance, ammonia tests pending
ITALCEMENTI Vibo Valentia, Italy 790 50 30 2 years of operation , modifications for 10% increase efficiency
HOLCIM Hon Chong, VI 750 50 25 2 years of satisfactory operation
ITALCEMENTI Vassiliko, Cyprus Target 800 Guaranteed 50 - To be commissioned Dec 2009
28Fives Pillard
SITE ASSISTANCE SERVICES
Real-time combustion controls
Decreasing NOx emission needs an increase of P.C concentration.It is servo-controlled by the line pressure drop.
NEW PATENTEP 00.401340.5 of May 16,2000
Enables to control via INTERNET:
Fives Pillard improved a well-known probe and offers it with
,for SO2, NOx, CO, O2 analyzers
: Our specialists operate worldwide.
coal/petcoke dosing systems :STAPILDOS
Burner Management System :ROTASAFE
sampling probes at kiln inlet :ROTASAMPLER
: 200 m: 8 kg/Nm3: +/- 1,5 %
Max length of conveying lineMax coal/petcoke concentrationStability of coal/petcoke flow
; Flow rates of each fuel (incl. A.S.F.); Burner adjustments & combustion measurements
29Fives Pillard
Combustion in rotary kilns & precalciners: conclusions
The NOVAFLAM burner is simple to adjust
The NOVAFLAM burner allows: a very high % of Alternative Solid Fuels minimum electric consumption recovering the existing carriage and primary air fan
The NOVAFLAM LOW-NOx, in association with the NEUTRINOX system, allows to meet emission limits AT STACK
The Fives Pillard group wants to develop a SPIRIT OF PARTNERSHIP with your Group aiming at proposing the best adequate solutions on a case by case basis.
We invite you to come and visit us in Marseilles, where all detailed questions will be answered!
Fives Pillard 30
With our warm thanks!All the Fives Pillard Management